Loading...
HomeMy WebLinkAboutTruss Engs � 1®Y O® Lumber design values are in accordance with ANSI/TPI 1-2014 section 6.3 .®, ®1 ROOF These truss designs rely on lumber values established by others. AAV TRUSSES A FLORIDA CORPORATION RE: Job ARMSSMB JOB #78750 A-1 Roof Trusses 4451 St Lucie Blvd Site Information: Fort Pierce, FL 34946 Customer Info: RENAR DEVELOPMENT CO. Project Name: MORNINGSIDE Lot/Block: Model: SEAMIST 2215 Address: Subdivision: City: County: St Lucie State: FL Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: General Truss Engineering Criteria Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC 2017 RES / TPI 2014 Design Program: Alpine Engineered Products Wind Code: ASCE 7-10 Wind Speed: 160 Roof Load: 40.0 psf Floor Load: 55.0 psf This package includes 24 individual, dated Truss Design Drawings and 16 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61 G15-31.003,section 5 of the Florida Board of Professional Engineers Rules. No. Seq # Truss Name Date No. Seq # Truss Name Date No. Seq # Truss Name Date 1 2544 FG01 9/11/20 13 2692 B01 9/11/20 25 STDL01 STD. DETAIL 9/11/20 2 2521 FL01 9/11/20 14 2695 B02GE 9/11/20 26 STDL02 STD. DETAIL 9/11/20 3 2682 FL02 9/11/20 15 2562 C01 9/11/20 27 STDL03 STD. DETAIL 9/11/20 4 2664 FL02GE 9/11/20 16 2710 CO2 9/11/20 28 STDL04 STD. DETAIL 9/11/20 5 2512 FL03 9/11/20 17 2752 CO3 9/11/20 29 STDL05 STD. DETAIL 9/11/20 6 2547 FL03GE 9/11/20 18 2749 D01 9/11/20 30 STDL06 STD. DETAIL 9/11/20 17 2508 FL04 9/11/201 19 2719 D02GE 9/11/20 31 STDL07 STD. DETAIL 9/11/20 8 2551 FL05 9/11/20 20 12557 HJ7 9/11/201 32 1 STDL08 STD. DETAIL 9/11/20 19 2548 FL07GE 9/11/20 21 2722 11 9/11/20 33 STDL09 STD. DETAIL 9/11/20 10 2689 A01GE 9/11/20 22 2737 J3 9/11/20 34 STDL10 STD. DETAIL 9/11/20 11 2743 A02_ 9/11/20 23 2565 J5 9/11/20 35 STDL11 STD. DETAIL 9/11/20 12 12704 A02GE 19/11/201 24 2554 J7 9/11/20 136 STDL12 I STD. DETAIL 9/11/20 tie truss drawing(s) referenced have been prepared byapme Engineered Products, Inc. under my direct supervision based on the parameters provided byA 1 RoofTrusses, Ltd. Truss Design Engineer's Name: Rama Pranav Kristam My license renewal date for the state of Florida is February 28,2021. NOTE: The seal on these drawings indicate acceptance of professional engineering responsibility solelyforthe truss components shown. The suitability and use of components for any particular building is the responsibility of the building designer, perANSUTPI-1 Sec. 2. The Truss Design Drawing(s)(TDD[s]) referenced have been prepared based on the construction documents (also referred to at times as'Structural Engineering Documents') provided by the Building Designer indicating the nature and character of the work. The design criteria therein have been transferred to Rama Pranav Kristam PE by [Al Roof Trusses or specific location]. These TDDs (also referred to at times as'Structural Delegated' Engineering Documents) are specialty structural component designs and may be part of the project's deferred or phased submittals. As a Truss Design Engineer (i.e, Specialty Engineer), the seal here and on the TDD represents an acceptance of professional engineering responsibility forthe design of the single Truss depicted on the TDD only. The Building Designer is responsible for and shall coordinate and review the TDDs for compatibility with theirwritten engineering requirements. Please review all TDDs and all related notes. Page 1 of 2 1tttSlttlllift//I��! No- 88 6 r � r Rama Pranav Kristam, P.E. 4451 St Lucie Blvd. Suite 201 Fort Pierce, FL 34946 OF Rama Pranav Knstam, P.E. # 88906 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 � T Lumber design values are in accordance with ANSI/TPI 1-2014 section 6.3 A-1 ROOF These truss designs rely on lumber values established by others. TRUSSES A FLORIDA CORPORATION RE: Job ARMSSMB No. Seq # Truss Name Date 37 STDL13 STD. DETAIL 9/11/20 38 STDL14 STD. DETAIL 9/11/20 39 STDL15 STD. DETAIL 9/11/20 40 STDL16 I STD. DETAIL 9/11/20 Rama Pranav Mstam, P.E. 488906 Page 2 of 2 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 ARMSSMB FG01 FLAT 2 , 2544 5 16'8"8 =3X12 =5X10 III1.5X3 III1.5X3 =6X6 =5X10 =3X12 A B C D E F G SEAT PLATE REQ. 16'8"8 Loading Criteria (psf) Wind Criteria Code / Misc Criteria Defl/CSI Criteria TCLL: 40.00 Wind Std: NA Code: FBC 2017 RES PP Deflection in loc L/defl L/# TCDL: 10.00 Speed: NA mph TPI Std: 2014 VERT(LL): 0.095 D 999 36 BCLL: 0.00 Enclosure: NA Rep Factors Used: No VERT(CL): 0.447 D 448 24 BCDL: 5.00 Category: NA FT/RT:10(0)/10(10) HORZ(LL): 0.017 H - - EXP: NAKzt: NA Plate Type(s): HORZ(TL): 0.079 H Des 00 Mean Height: NA ft WAVE, HS NCBCLL: 00.0.00 TCDL: NA psf Creep Factor: 2.0 Load Duration: 1.00 BCDL: NA psf Max TC CSI: 0.453 Spacing: 24.0 " MWFRS Parallel Dist: NA Max BC CSI: 0.835 C&C Dist a: NA ft Max Web CSI: 0.798 Loc. from endwall: NA Wgt: 207.2 Ibs I: NA GCpi: NA VIEW Ver: 19.01.00A.0618.16 Wind Duration: NA Lumber Top chord 2x8 SP 2400f-1.8E Bot chord 2x4 SP 2400f-2.0E Webs 2x4 SP #3 W1 2x6 SP #2; W2,W5 2x4 SP #2; Nailnote Nail Schedule:0.131"x3", min. nails Top Chord: 1 Row @ 6.50" o.c. Bot Chord: 1 Row @12.00" o.c. Webs : 1 Row @ 4" o.c. Use equal spacing between rows and stagger nails in each row to avoid splitting. (1) 1/2" bolts may be used for (2) 0.131"x3", min. nails on The Top Chord Only. Special Loads -----(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 389 pIf at 0.00 to 389 pIf at 16.71 BC: From 10 pIf at 0.00 to 10 plf at 16.71 Purlins In lieu of structural panels or rigid ceiling use puriins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.00 16.71 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. The TC of this truss shall be braced with attached spans at 24" oc in lieu of structural sheathing. Additional Notes Truss must be installed as shown with top chord up. ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL P 3333/- H 3333/- P Brg Width = 4.0 Min Req = 1.5 H Brg Width = 3.5 Min Req = 1.5 Bearings P & H are a rigid surface. Bearing P requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A- B 0- 2601 D- E 0- 6669 B- C 0- 6669 E- F 0- 6669 C- D 0- 6758 F- G 0- 2614 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp P-O 58 0 L-K 6758 0 O- N 4734 0 K- J 4753 0 N- M 4734 0 J- 1 4753 0 M-L 4734 0 1 - H 58 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. A-P 0 -1631 D-K 0 -550 A-O 2815 0 K -F 2051 0 O-B 0 -2453 F -J 9 0 B-N 10 0 F - 1 0 -2461 B- L 2068 0 1- G 2828 0 L- C 0- 553 G- H 0 -1631 `"'WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineenri responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Tres Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Cn-mlit n 201A A-1 Roof To-—- Rrnrnduntinn of Him dnr."mnnt in an, forn. is nrohihitnd withniil tha wdttrn nanni-inn of A-1 Roof Tmesaa. ARMSSMB I FL01 I SY42 12 11 ( -- 2521 f -- 2'6n �--{ (T'P) 5'3" 7'3"----- 127"8 III1.5X3 =3X6 III1.5X3 III1.5X3 =3X6 A B C D E L 1.5X3(R) M K III 1.5X3 F R) G 1.5X3(R) N P0 = 3X4 =3X4 3"1 SEAT PLATE REQ. = 3X4 =3X4 3"1 SEAT PLATE REQ. 12'7"8 Loading Criteria (pst) Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 40.00 Wind Sid: NA Code: FBC 2017 RES PP Deflection in loc L/defl L/# Gravity Non -Gravity TCDL: 10.00 Speed: NA mph TPI Sid: 2014 VERT(LL): 0.118 C 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: NA Rep Factors Used: Yes VERT(CL): 0.195 C 744 240 K 681 BCDL: 5.00 Category: NA FT/RT:10(0)/10(10) HORZ(LL): 0.022 B - - H 681 Des Ld: 55.00 EXP: NA Kzt: NA Plate Type(s): HORZ(TL): 0.036 B - - K Brg Width = 7.5 Min Req = 1.5 Mean Height: NA ft WAVE Creep Factor: 2.0 H Erg Width = 3.5 Min Req = 1.5 NCBCLL: 0.00 TCDL: NA psf Max TC CSI: 0.571 Bearings K & H are a rigid surface. Load Duration: 1.00 " BCDL: NA psf Max BC CSI: 0.658 Bearing K requires a seat plate. Spacing: 24.0 MWFRS Parallel Dist: NA C&C Dist a: NA ft Max Web CSI: 0.346 Maximum Top Chord Forces Per Ply (Ibs) Loc. from endwall: NA Chords Tens.Comp. Chords Tens. Comp. Wgt: 70.0 Ibs I: NA GCpi: NA A- B 1 0 D- E 0 -1651 Wind Duration: NA VIEW Ver: 19.01.00A.0618.16 B - C 0 -1651 E - F 1 0 Lumber C - D 0 -1663 Top chord 4x2 SP #2 Bot chord 4x2 SP #2 Maximum Bot Chord Forces Per Ply (Ibs) Webs 4x2 SP #3 Chords Tens.Comp. Chords Tens. Comp. Purlins K- J 1125 0 1- H 1125 0 In lieu of structural panels or rigid ceiling use purlins J -1 1663 0 to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) Maximum Web Forces Per Ply (Ibs) BC 120 0.25 12.38 Webs Tens.Comp. Webs Tens. Comp. Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. L - M 0 -4 D - I 0 -217 A-K 0 -108 1 - E 656 0 Additional Notes K- B 0 -1250 E- H 0 -1250 + 2x6 continuous strongback. B - J 656 0 F - H 0 -108 Truss must be installed as shown with top chord up. J - C 0 -217 G - N 0 -4 "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (Too) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building, All capitalized terns are as defined in TPI-1. C: nnht n 20te A-1 Rnnf Tmnsnc — Rnnrnnnntinn of thin dnrnjmnnfin anv form. is nmhihitnd Athr nl thn wnftt n —Inninn of AA Rnnf Tnc n ARMSSMB FL02 ,N SY42 . y , ,y 1 1 2682 �-- 2,6" --� (TYP) �-- 63" -{— 7'9"8 ----}— 12'5" ---}— 14-11 "8 --{— 17'9" 1 20'78 --{ 1.5X3(R) =3X6 =3X6 W=3X6 =3X8 =3X4 1112X4 3"1 A B S C D E F G H I J 1.5X3(R)TLe� 3"1 Q P O N M L K =3X4 =3X4 =3X4 W=3X6 =3X8 1114X4 =3X6 2'5" 2'5" SEAT PLATE REQ. 175"12 i 81"12 --i 20'7"8 Loading Criteria (pso Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 40.00 Wind Sid: NA Code: FBC 2017 RES PP Deflection in loc L/defl L/# Gravity Non -Gravity TCDL: 10.00 Speed: NA mph TPI Std: 2014 VERT(LL): 0.169 C 867 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: NA Rep Factors Used: Yes VERT(CL): 0.266 C 551 240 R 692/- BCDL: 5.00 Category: NA FT/RT:10(0)/10(10) HORZ(LL): 0.033 B - - N 1144 /- /- EXP: NA Kzt: NA Plate Type(s): HORZ(TL): 0.053 B - - K 472 Des Ld: 55.00 Mean Height: NA ft WAVE Creep Factor: 2.0 R Brg Width = 7.5 Min Req = 1.5 NCBCLL: 0.00 TCDL: NA sf p Max TC CSI: 0.978 N Brg Width = 3.5 Min Req = 1.5 Load Duration: 1.00 BCDL: NA psf K Brg Width = - Min Req = - Spacing: 24.0 " MWFRS Parallel Dist: NA Max BC CSI: 0.733 Bearings R & N are a rigid surface. C&C Dist a: NA ft Max Web CSI: 0.353 Bearing R requires a seat plate. Loc. from endwall: NA Wgt: 114.8 Ibs Maximum Top Chord Forces Per Ply (Ibs) I: NA GCpi: NA Chords Tens.Comp. Chords Tens. Comp. Wind Duration: NA VIEW Ver: 19.01.00A.0618.16 Lumber A- B 1 0 F- G 218 -120 B - C 0 -1683 G - H 218 -120 Top chord 4x2 SP #2 C - D 0 -1695 H - 1 0 - 701 Bot chord 4x2 SP #2 D- E 0 -1681 I- J 3 0 Webs 4x2 SP #3 E-F 218 -120 Plating Notes All plates are 1.5X3 except as noted. Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. Purlins R-Q 1145 0 N-M 700 0 In lieu of structural panels or rigid ceiling use purlins Q - P 1695 0 M - L 701 0 to laterally brace chords as follows: P - O 1191 0 L - K 699 0 Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.25 20.38 O - N 1191 0 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. Additional Notes + 2x6 continuous strongback. S - T 0 -4 G - N 0 -291 A-R 0 -108 N-H 0 -810 Truss must be installed as shown with top chord up. R - B 0 -1273 H - M 69 -7 B- Q 628 0 L- I 56 -27 Q- C 0- 226 1- K 0 - 779 D-P 0 -302 K-J 0 -15 P-E 720 0 J -K 0 -127 E-N 0-1239 "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineenn responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pmnav Kristam, P.E. responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Tmss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Cnnvrinht n 2016 AA Roof Tmssas — Ranrndnntion of this don—entin anv fnnnis nrohihitad without the wnttan nannissino of AA Roof Tmctas. ARMSSMB FL02GE I SY42 ( 2 ( 12664 ' I VV H f- 1,4"-- (TYP) 1'3"41 I 17 3 4 18'3A 2'7"4 III2X4 =3X3 =3X3 1112X4 A B C D E F G H I J K L M N O AD AC AA Z Y X W V U T S 1112X4(R) =3X3 SEAT PLATE REQ. 18'3"8 Loading Criteria (psf) Wind Criteria Code / Misc Criteria TCLL: 40.00 Wind Std: NA Code: FBC 2017 RES TCDL: 10.00 Speed: NA mph TPI Std: 2014 BCLL: 0.00 Enclosure: NA Rep Factors Used: Yes BCDL: 5.00 Category: NA FT/RT:10(0)/10(10) EXP: NAKzt: NA Plate Type(s): Des Ld: 55.00 Mean Height: NA ft WAVE NCBCLL: 0.00 TCDL: NA psf Load Duration: 1.00 BCDL: NA psf Spacing: 24.0 " MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA 1: NA GCpi: NA Wind Duration: NA Lumber Top chord 4x2 SP #2 Bot chord 4x2 SP #2 Webs 4x2 SP #3 .END Bracing Sheathing is required for any longitudinal (drag) forces. All connections to be designed by the building designer. Plating Notes All plates are 1.5X3 except as noted. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.25 18.04 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Additional Notes Truss must be installed as shown with top chord up. R Q III 3X3 Defl/CSI Criteria ♦ Maximum Reactions (Ibs), or *=PLF PP Deflection in loc L/defl L/# Gravity Non -Gravity VERT(LL): 0.000 D 999 360 Loc R+ / R- / Rh / Rw / U / RL VERT(CL): 0.000 D 999 240 p* 110 /-/- HORZ(LL): 0,000 O - - P Brg Width = 219 Min Req = - HORZ(TL): 0.000 O Bearing AD is a rigid surface. Creep Factor: 2.0 Bearing AD requires a seat plate. Max TC CSI: 0.085 Maximum Top Chord Forces Per Ply (Ibs) Max BC CSI: 0.009 Chords Tens.Comp. Chords Tens. Comp. Max Web CSI: 0.032 A- B 3 0 H- 1 2 0 Wgt: 109.2 Ibs B- C 10 0 1-1 2 0 C-D 2 0 J-K 2 0 VIEW Ver: 19.01.00A.0618.16 D- E 2 0 K- L 2 0 E-F 2 0 L-M 2 0 F-G 2 0 M-N 8 0 G-H 2 O N-O 3 0 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. AD -AC 0 -3 W-V 0 -2 AC -AB 4 0 V- U 0 -2 AB -AA 0 -2 U-T 0 -2 AA-Z 0 -2 T-S 0 -2 Z-Y 0 -2 S-R 0 -2 Y-X 0 -2 R-Q 4 0 X-W 0 -2 Q-P 0 -3 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. A -AD 0 -70 P-O 0 -15 AC-C 0 -19 O-P 0 -34 M-Q 0 -18 Maximum Gable Forces Per Ply (Ibs) Gables Tens.Comp. Gables Tens. Comp. B-AC 0 -129 I-V 0 -133 C-AB 0 -121 J-U 0 -134 D-AA 0 -138 K-T 0 -132 E-Z 0 -132 L-S 0 -137 F-Y 0 -134 R-M 0 -126 G-X 0 -133 Q-N 0 -109 H-W 0 -133 **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (Too) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineers responsibility for the design of the single Truss depicted on the TDD only, under TPI-1, The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. C:onvrinht 0 2016 A-1 Roof Tnn ses - Ronroduntion of this domimentin anv formis nmhihited without the wrifnn nm—is ino of A-1 Rnnf Tnisses. Rama Pranav Kristam, P.E. # 88906 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 ' I ARMSSMB I FL03 ( SY42 "rL 3r 1 1 r I .......... 2512 F-- 2'6" --I (TYP) j= 9'1"8 1.5X3(R) 3"1 A 1.5X3(R)Ts 3"1 .AYR SEAT PLATE REQ. =4X8 B Loading Criteria (pst) Wind Criteria TCLL: 40.00 Wind Std: NA TCDL: 10.00 Speed: NA mph BCLL: 0.00 Enclosure: NA BCDL: 5,00 Category: NA EXP: NAKzt: NA Des Ld: 55.00 Mean Height: NA ft NCBCLL: 0.00 TCDL: NA psf Load Duration: 1.00 BCDL: NA psf Spacing: 24.0 " MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Lumber Top chord 4x2 SP M-30 T2 4x2 SP #2; Bot chord 4x2 SP M-30 Webs 4x2 SP #3 .END Plating Notes All plates are 1.5X3 except as noted. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.25 20.38 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Deflection Max JT VERT DEFL: LL: 0.50" DL: 0.25". Additional Notes Truss must be installed as shown with top chord up. 11'8" =3X4 3X4 W=3X6 C D E FG H I 20'7"8 =4X8 J 1112X4 K Q = 3X12 P O N W=H0312 =3X4 =3X4 2rCn 20'7"8 M =3X12 L =3X8 Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 2017 RES PP Deflection in loc L/defl L/# Gravity Non -Gravity TPI Std: 2014 VERT(LL): 0.501 E 482 360 Loc R+ / R- / Rh / Rw / U / RL Rep Factors Used: Yes VERT(CL): 0.631 E 382 240 R 1120/- FT/RT:10(0)/10(10) HORZ(LL): 0.063 L - L 1135 !- /- /- /- A Plate Type(s): HORZ(TL): 0.087 L R Brg Width = 7.5 Min Req = 1.5 WAVE, HS Creep Factor: 2.0 L Brg Width = - Min Req = - Max TC CSI: 0.934 Bearing R is a rigid surface. Max BC CSI: 0.839 Bearing R requires a seat plate. Max Web CSI: 0.781 Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. Wgt: 110.6 Ibs A- B 1 0 F- G 0 -4538 VIEW Ver. 19.01.00A.0618.16 B- C 0 -3514 G- H 0 -4538 C -D 0-3514 H - 1 0 -3510 D- E 0- 4540 I- J 0- 3510 E-F 0 -4549 J -K 3 0 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. R- Q 2030 0 O- N 4549 0 Q- P 4338 0 N- M 4346 0 P- O 4338 0 M- L 2028 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. S-T 0 -4 F-N 51 -437 A-R 0 -110 N-H 691 -121 R- B 0- 2255 H- M 0 - 925 B-Q 1641 0 1 - M 0 -258 C- Q 0- 258 M- J 1638 0 Q-D 0 -911 J -L 0 -2255 D-O 663 -124 L-K 0 -15 O-E 37 -366 K-L 0 -114 **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER') ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineeri responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-I. Conwinhf n 2f)1E A-1 Rnnf Tnieo - Renmdnrtinn of this donnmont in anv form is nrnhihitnti without tho written n"nni-ion of A-1 Roof Tnic¢ Rama Pranav Mstam, P.E. 1188906 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 ARMSSMB H FL03GE SY42 1 1 (TYP) (- 1'3n4 ,-f — 27"4 -1 1 V11 "4 1274 2547 1112X4 =3X3 =3X3 1112X4 A B C D E F G H I J K Loading Criteria (psi) Wind Criteria TCLL: 40.00 Wind Std: NA TCDL: 10.00 Speed: NA mph BCLL: 0.00 Enclosure: NA BCDL: 5.00 Category: NA EXP: NAKzt: NA Des Ld: 55.00 Mean Height: NA ft NCBCLL: 0.00 TCDL: NA psf Load Duration: 1.00 BCDL: NA psf Spacing: 24.0 " MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Lumber Top chord 4x2 SP #2 Bot chord 4x2 SP #2 Webs 4x2 SP #3 .END Plating Notes All plates are 1.5X3 except as noted. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.25 12.38 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Additional Notes Truss must be installed as shown with top chord up. L ;R) E REQ. Code / Misc Criteria Defl/CSl Criteria ♦ Maximum Reactions (Ibs), or *=PLF Code: FBC 2017 RES PP Deflection in loc L/defl L/# Gravity Non -Gravity TPI Std: 2014 VERT(LL): 0.006 J 999 360 Loc R+ / R- / Rh / Rw / U i RL V* 216/- Rep Factors Used: No VERT(CL): 0.008 J 999 240 FT/RT:10(0)/10(10) HORZ(LL): 0.000 K - - L 212 /- /- /- /- A Plate Type(s): HORZ(TL): 0.000 K V Brg Width = 144 Min Req = - WAVE Creep Factor: 2.0 L Brg Width = 7.5 Min Req = 1.5 Max TC CSI: 0.337 Bearings V & M are a rigid surface. Max BC CSI: 0.196 Bearings V & M require a seat plate. Max Web CSI: 0.077 Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. Wgt: 81.2 Ibs A-B 6 O F-G 8 0 VIEW Ver: 19.01.00A.0618.16 B- C 20 0 G- H 8 0 C-D 8 0 H-1 23 0 D-E 8 0 1-J 6 0 E-F 8 0 J -K 6 0 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp V-U 0 -6 Q-P 0 -8 U-T 5 0 P-O 0 -8 T-S 0 -8 O-N 4 0 S-R 0 -8 N-M 0 -6 R-Q 0 -8 M-L 0 -6 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. A-V 0 -147 L-K 0 -29 U-C 0 -36 K-L 0 -93 H-N 0 -39 Maximum Gable Forces Per Ply (Ibs) Gables Tens.Comp. Gables Tens. Comp B-U 0 -279 G-P 0 -302 C- T 0- 265 O- H 0 - 246 D- S 0- 299 N- 1 0 - 335 E-R 0 -287 J -M 0 -119 F - Q 0 - 286 -WARNING`* Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (Le, Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineenn responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field t188906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. (;nn,nnht n 201a A-i Rnn(Tn tssa_v- R"nrndimlinn of this dncnmonf. in anv form. is nrnhihife,d vrithnnt the, wnttrn nnrmi-inn of AA Rnnf Tniet .1,— 2508 ARIISSMBFL04 SY42 F 1 E-- 2,6" --� (TYP) 9' 1 "8 11'8" 20' 11 =3X4 1.5X3(R) =4X8 =3X4 W=3X6 =4X8=1.5X3(R) 3"1 TA B C D E FG H I J K 31 L 1.5X3(R) =1.5X3(R) 3"1 R Q P O N M 3"1 =4X6 =3X12 W=H0312 =3X4 =3X4 =3X12 =4X6 SEAT PLATE REQ. 20'11" Loading Criteria (psf) Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 40.00 Wind Std: NA Code: FBC 2017 RES PP Deflection in loc L/defl L/# Gravity Non -Gravity TCDL: 10.00 Speed: NA mph TPI Std: 2014 VERT(LL): 0.515 F 475 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: NA Rep Factors Used: Yes VERT(CL): 0.649 F 377 240 S 1137/- BCDL: 5.00 Category: NA FT/RT:10(0)/10(10) HORZ(LL): 0.066 M - - M 1137 EXP: NA Kzt: NA Des Ld: 55.00 Plate Type(s): HORZ(TL): 0.090 M S Brg Width = 7.5 Min Req = 1.5 Mean Height: NA ft WAVE, HS Creep Factor: 2.0 M Brg Width = 3.5 Min Req = 1.5 NCBCLL: 0.00 TCDL: NA sf p Max TC CSI: 0.931 Bearings S & M are a rigid surface. Load Duration: 1.00 BCDL: NA psf " Max BC CSI: 0.846 Bearing S requires a seat plate. Spacing: 24.0 MWFRS Parallel Dist: NA Max Web CSI: 0,799 Maximum Top Chord Forces Per Ply (Ibs) C&C Dist a: NA ft Chords Tens.Comp. Chords Tens. Comp. Loc. from endwall: NA Wgt: 109.2 Ibs I: NA GCpi: NA A- B 1 0 F- G 0 -4675 Wind Duration: NA VIEW Ver: 19.01.00A.0618.16 B - C 0 -3581 G - H 0 -4675 I Lumber C- D 0 -3581 H -1 0 -3580 D - E 0 -4675 I - J -3580 Top chord 4x2 SP M-30 T2 4x2 SP #2; E- F 0 -4685 J- K 1 1 0 Bot chord 4x2 SP M-30 Webs 4x2 SP #3 .END Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. Plating Notes S- R 2063 0 P- O 4685 0 All plates are 1.5X3 except as noted. R - Q 4441 0 O - N 4444 0 Q- P 4441 0 N- M 2064 0 Purlins In lieu of structural panels or rigid ceiling use purlins Maximum Web Forces Per Ply (Ibs) to laterally brace chords as follows: Webs Tens.Comp. Webs Tens. Comp. Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.25 20.67 T - U 0 - 4 F - O 26 - 383 Apply purlins to any chords above or below fillers A - S 0 -110 O - H 699 -106 at 24" OC unless shown otherwise above. S - B 0 -2292 H - N 0 -956 Deflection B- R 1678 0 1- N 0 - 257 C - R 0 -25N - J 1676 0 Max JT VERT DEFL: LL: 0.51" DL: 0.26". R- D 0- 951 1 J- M 0- 2293 Additional Notes D - P 705 -106 K - M 0 -110 P-E 25 -388 L-V 0 -4 Truss must be installed as shown with top chord up. .'WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineers responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms areas defined in TPI-1. Cnnvrinht n 2Ma A-1 Rnnf TnittP_v — Ranrnrinrfinn o(fhia AnrumPnt. in anv form. is nmhihiloA without ihn writton nvnniztinn of A-1 Rnnf Tni ., Rama Pranav Kristam, P.E. # 88906 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 "YP, �.0y �y wf � uww ARMSSMB FL05 SY42 6 1r 1 2551 �— — 2'6" (TYP) 9' 1 "8 11'8" --^{ =3X4 =1.5X3(R) =4X8 =3X4 W=3X6 3"1 TA B C D E FG H a=1.5X3(R) 31 R Q P O =4X6 =3X12 W=H0312 =3X4 =3X4 SEAT PLATE REQ. Loading Criteria (psf) Wind Criteria TCLL: 40.00 Wind Std: NA TCDL: 10.00 Speed: NA mph BCLL: 0.00 Enclosure: NA BCDL: 5.00 Category: NA EXP: NAKzt: NA Des Ld: 55.00 Mean Height: NA ft NCBCLL: 0.00 TCDL• NA psf Load Duration: 1.00 BCDL: NA psf Spacing: 24.0 " MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Lumber Top chord 4x2 SP M-30 T2 4x2 SP 42; Bot chord 4x2 SP M-30 Webs 4x2 SP #3 .END Plating Notes All plates are 1.5X3 except as noted. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.25 20.67 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Deflection Max JT VERT DEFL: LL: 0.51" DL: 0.26". Additional Notes Truss must be installed as shown with top chord up. 20'11" — 20'11" =4X8 I J N =3X12 1.5X3(R) K L 3„1 1.5X3(R) 3"1 M SEAT PLATE REQ. Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 2017 RES PP Deflection in loc L/defl L/# Gravity Non -Gravity TPI Std: 2014 VERT(LL): 0.515 F 475 360 Loc R+ ! R- / Rh / Rw / U / RL Rep Factors Used: Yes VERT(CL): 0.649 F 377 240 S 1137 !- !- /- /- A FT/RT:10(0)/10(10) HORZ(LL): 0.066 M - - M 1137 A A /- /- A Plate Type(s): HORZ(TL): 0.090 M - - S Brg Width = 7.5 Min Req = 1.5 WAVE, HS Creep Factor: 2.0 = 7.5 Min Re 1.5 g Width M Br Wi q = Max TC CSI: 0.931 Bearings S & M are a rigid surface. Max BC CSI: 0.845 Bearings S & M require a seat plate. Max Web CSI: 0.799 Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. Wgt: 109.2 Ibs A-B 1 0 F-G 0 -4675 VIEW Ver: 20.01.01A.0724.11 B- C 0 -3581 G- H 0 -4675 C- D 0- 3581 H -1 0- 3580 D- E 0-4675 1- J 0 -3580 E-F 0-4685 J -K 1 0 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. S- R 2063 0 P- O 4685 0 R- Q 4441 0 O- N 4444 0 Q- P 4441 0 N- M 2064 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. T-U 0 -4 F-O 26 -383 A-S 0 -110 O-H 699 -106 S- B 0- 2292 H- N 0 - 956 B- R 1678 0 1- N 0 - 257 C- R 0- 259 N- J 1676 0 R- D 0- 951 J- M 0- 2293 D-P 705 -106 K-M 0 -110 P-E 25 -388 L-V 0 -4 `"WARNING`" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam. P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-I. (:nnvnnht (2016 A-1 Rnnf Tmesrs — Ranrnd-Aion of this dncnmantin anv fnnn. is nrnhihr1.d withnnt the writ.. nnnniscinn of A-1 Rnnf Tnicsae. ARI ISSMB FL07GE SY42 (TYP) W=3X6 =1.5X3(R) =3X3 3"1 AD AB C DE F a=1.5X3AA(RR� 3"1 20'4"12 G H I J K AB AA Z Y X W V =3X3 SEAT PLATE REQ. 20'11" U TS W=3X6 2548 1.5X3(R) L MN 0 3"1 1.5X3(R) AF 3"1 P R Q SEAT PLATE REQ. Loading Criteria (psi) Wind Criteria Code / Misc Criteria Deft/CSI Criteria ♦ Maximum Reactions (Ibs), or *=PLF TOLL: 40.00 Wind Std: NA Code: FBC 2017 RES PP Deflection in loc L/defl L/# Gravity Non -Gravity TCDL: 10.00 Speed: NA mph TPI Std: 2014 VERT(LL): -0.002 N 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: NA Rep Factors Used: Yes VERT(CL): -0.002 N 999 240 AC*106/- BCDL: 5.00 Category: NA FT/RT:10(0)/10(10) HORZ(LL): -0.000 B - - P 127 EXP: NAKzt: NA Plate Type(s): HORZ(TL): 0.000 B AC Brg Width = 243 Min Req = - Des Ld: 55.00 Mean Height: NA ft WAVE Creep Factor: 2.0 P Brg Width = 7.5 Min Req = 1.5 NCBCLL: 0.00 TCDL: NA sf p Max TC CSI: 0.208 Bearings AC & Q are a rigid surface. Load Duration: 1.00 BCDL: NA psf " Max BC CSI: 0.056 Bearings AC & Q require a seat plate. Spacing: 24.0 MWFRS Parallel Dist: NA Max Web CSI: 0.050 Maximum Top Chord Forces Per Ply (Ibs) C&C Dist a: NA ft Chords Tens.Comp. Chords Tens. Comp. Loc. from endwall: NA Wgt: 102.2 Ibs I: NA GCpi: NA A- B 1 0 H- 1 1 0 Wind Duration: NA VIEW Ver: 20.01.01A.0724.11 B- C 1 0 1-1 1 0 Lumber C- D 11 0 J- K 1 0 D- E 1 0 K- L 1 0 Top chord 4x2 SP #2 E- F 1 0 L- M 1 0 Bot chord 4x2 SP #2 F- G 1 0 M- N 1 0 Webs 4x2 SP #3 G-H 1 0 .END Plating Notes Maximum Bot Chord Forces Per Ply (Ibs) All plates are 1.5X3 except as noted. Chords Tens.Comp. Chords Tens. Comp. AC -AB 0 -1 V - U 0 -1 Puriins AB -AA 0 -1 U - T 0 -1 In lieu of structural panels or rigid ceiling use puriins AA- Z 9 0 T - S 0 -1 to laterally brace chords as follows: Z - Y 0 -1 S - R 0 1 Chord Spacing(in oc) Start(ft) End(ft) Y- X 0 1 R- Q 0 1 BC 120 0.25 20.67 X - W 0 1 Q - P 0 1 Apply puriins to any chords above or below fillers W - V 0 1 at 24" OC unless shown otherwise above. Additional Notes Maximum Web Forces Per Ply (Ibs) Truss must be installed as shown with top chord up. Webs Tens.Comp. Webs Tens. Comp. AD-AE 0 0 N- P 38 0 A -AC 76 0 O -AF 0 -1 AA- D 0 - 24 Maximum Gable Forces Per Ply (Ibs) Gables Tens.Comp. Gables Tens. Comp. B -AB 0- 203 1- V 0 - 200 C -AA 0- 205 J- U 0 - 201 D-Z 0 -185 K-S 0 -196 F-Y 0 -205 L-R 0 -216 G-X 0 -199 M-Q 0 -158 H - W 0 - 200 -WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. (:nnvdnht n 201E A-1 Rnnf Tmsw..¢ - Renrndnntinn of this dnfAlment. in anv fnnn. is nrnhihited withniR the written nermis[inn of A-1 Rnnf Tnieses ARMSSMB A01GE GABL r I I VV' 2689 r 1671 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #3 Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Code / Misc Criteria Code: FBC 2017 RES TPI Sid: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Bracing (a) Continuous lateral restraint equally spaced on member. Fasten rated sheathing to one face of this frame. Plating Notes All plates are 1.5X3 except as noted. (**) 1 plate(s) require special positioning. Refer to scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 16.25 25.28 BC 120 0.00 25.28 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Additional Notes See STD DETAILS for gable wind bracing requirements. Defl/CSI Criteria ♦ Maximum Reactions (Ibs), or *=PLF PP Deflection in loc L/defl L/# Gravity Non -Gravity VERT(LL): -0.010 AE 999 36 Loc R+ / R- / Rh / Rw / U / RL VERT(CL): -0.014 AE 999 24 AF 201 /- !- 1165 /105 /455 HORZ(LL): -0,036 C - - R* 80 /- /- /48 /30 /- HORZ(TL): 0.042 C Wind reactions based on MWFRS Creep Factor: 2.0 AF Brg Width = 7.4 Min Req = 1.5 Max TC CSI: 0.307 R Brg Width = 295 Min Req = - Max BC CSI: 0.178 Bearings AF & AE are a rigid surface. Max Web CSI: 0.246 Bearings AF & AE require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Wgt:249.2lbs Chords Tens.Comp. Chords Tens. Comp. VIEW Ver: 19.01.00A.0618.16 A - B 43 0 1-1 524 -108 B - C 149 - 62 J - K 601 -122 C-D 173 -48 K-L 541 -108 D - E 260 - 66 L - M 571 -109 E - F 320 - 75 M - N 571 -109 F-G 381 -86 N-O 571 -109 G - H 388 - 80 O - P 571 -109 H-1 456 -97 P-Q 1 0 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp AF-AE 122 - 599 Y - X 1 -2 AE-AD 1 -3 X-W 1 -2 AD -AC 1 -2 W - V 1 -2 AC -AB 1 -2 V - U 1 -2 AB -AA 1 -2 U-T 1 -2 AA-Z 1 -2 T-S 1 -2 Z-Y 1 -2 S-R 0 -1 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp AE-AG 126 -630 AR -AS 117 -610 AG-AH 131 -645 AS- X 226 -125 AH-AD 253 -187 AT -AU 116 - 609 AI-AJ 122 -619 AU- W 6 -133 AJ-AC 91 -105 AV-AW 116 - 608 AK -AL 123 -626 AW- V 62 -129 AL -AB 147 -127 AX-AY 116 - 611 AM -AN 121 -619 AY- U 111 -124 AN -AA 138 -124 AZ -BA 115 - 606 AO -AP 119 - 615 BA- T 106 -126 AP-AQ 119 - 615 BB -BC 118 - 617 AQ- Z 145 -124 BC- P 60 - 325 Maximum Gable Forces Per Ply (Ibs) Gables Tens.COmD. Gables Tens. Com **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kdstam, P.E. responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TOD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Convdnht * Mifi AA Ronf Tn.--- Ranmdnntinn of this dnnnment in anv fnnn. is nrnhihited Alhnnt the wnitnn nanniaeinn of A-1 Rnnf Tni<aes. i t UOJ i t UJJ I yL1C t,1ty riy Uy/ I r/LULU 2689 A01 GE GABL 1 1 AF- B 365 - 204 J -AT 235 -123 C -AG 55 - 53 K -AV 8 -135 D -AI 189 -152 M -AX 66 -130 E -AK 119 -114 N -AZ 98 -122 F -AM 140 -124 O -BB 146 -136 H -AO 137 -123 BC- S 271 -107 1-AR 137 -123 Q - R 58 -28 **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ('BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI-I. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Krislam, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-I. r;nnvdnht n 201fi A-1 Rnnf Tniasr-¢ - Ran d-jinn of this d—menf in anv formis nmhihitnd vAfhnut tha wnftan nannisainn of AA Rnnf Tnieaaa ARMSSMB A02 I GOMN 2743 el F Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " i 12'1 14'6'4 10'6' ---+1 SEAT PLATE REQ. 2572 12-5.12 -� Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.79 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP 2400f-2.OE T3,T4 2x4 SP M-30; T5 2x4 SP #2; Bot chord 2x4 SP #2 B2 2x4 SP M-30; Webs 2x4 SP #3 25'3'6 1218' 1, 4 3T1 V6 Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.143 C 999 360 VERT(CL): 0.298 C 999 240 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL Q 902 /- /- /526 /185 /450 FT/RT:10(0)/10(10) HORZ(LL): 0.063 C - - N 2363 /- /- /1588 /853 /- Plate Type(s): HORZ(TL): 0.130 C K 311 /-214 /- /248 /186 !- WAVE Creep Factor: 2.0 Wind reactions based on MWFRS Max TC CSI: 0.700 O Brg Width = 7.4 Min Req = 1.5 Max BC CSI: 0.984 N Brg Width = 3.5 Min Req = 2.8 Max Web CSI: 0.846 K Brg Width = 3.5 Min Req = 1.5 Bracing (a) Continuous lateral restraint equally spaced on member. Plating Notes (**) 1 plate(s) require special positioning. Refer to scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 69 0.20 25.28 BC 69 25.28 37.91 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Negative reaction(s) of -214# MAX. from a non -wind load case requires uplift connection. See Maximum Reactions. Shim all supports to solid bearing. Bearings O, IN, & K are a ngld surface. Wgt: 201.6 Ibs Bearing O requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) VIEW Ver: 19.01.00A.0618.16 I Chords Tens.Comp. Chords Tens, Comp. A- B 40 0 G- H 1824 -1048 B - C 1271 -= H - 1 1656 - 754 C - D 376 - 854 I - J 831 - 274 D - E 394 - 829 J - K 758 - 301 E-F 414 -729 K-L 35 0 F - G 1685 -1065 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. N - M 803 - 935 M - K 370 - 646 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp B - O 753 - 797 R - F 650 -188 B - P 2044 - 982 R - N 698 - 448 O - P 295 - 535 F - N 1528 - 2104 P - C 238 -86 N - H 675 -487 P - Q 2022 -1580 N -1 957 -1658 C - R 1087 -1270 I - M 577 - 400 Q - R 2070 -1572 M - J 466 - 362 *'WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Cnnvrinht C) 2n16 A-1 Rnnf TmssP_v - Renrndimlinn of this d--nnt in anv f rrn. is nmhihitnd wllhnnt the written nnrtnis.,inn of A-1 Rnnf Tnc ., ��' ARMSSMB A02GE I GABL�'~y 1 1,1,Y .......... 2704 10'6" 10'6"14 - H=3X4 =3X6 21'8"5 Loading Criteria (psf) Wind Criteria Code / Misc Criteria Defl/CSI Criteria TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc L/defl L/# TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): 0.006 N 999 36 BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.012 N 999 241 BCDL: 10.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): -0.003 E - EXP: B Kzt: NA Plate Type(s): HORZ(TL): 0.003 E Des Ld: 40.00 Mean Height: 25.00 ft WAVE NCBCLL: 10.00 TCDL: 5.0 psf Creep Factor: 2.0 Load Duration: 1.25 BCDL: 5.0 psf Max TC CSI: 0.256 Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 Max BC CSI: 0.124 C&C Dist a: 3.00 ft Max Web CSI: 0.070 Loc. from endwall: Any Wgt: 107.8 Ibs GCpi: 0.18 VIEW Ver: 19.01.00A.0618.16 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #3 Plating Notes All plates are 1.5X3 except as noted. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 75 0.15 21.69 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes See STD DETAILS for gable wind bracing requirements. Z-7 ♦ Maximum Reactions (Ibs), or *=PLF Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B* 86 /- /- /44 /32 /8 Wind reactions based on MWFRS B Erg Width = 260 Min Req = - Bearing B is a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-B 39 0 G-H 186 -25 B-C 62 -165 H - 1 185 -23 C-D 66 -118 I-J 130 -22 D - E 53 -49 J - K 53 -37 E - F 109 - 32 K - L 53 - 59 F-G 188 -21 L-M 78 -142 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp B - W 232 - 89 R - Q 205 - 70 W - V 239 - 91 Q - P 204 - 69 V - U 243 - 94 P - O 201 - 68 U - T 246 - 95 O - N 198 - 66 T - S 250 - 96 N - M 187 - 62 S - R 251 - 97 Maximum Gable Forces Per Ply (Ibs) Gables Tens.Comp. Gables Tens. Comp C-W 102 -87 Q-1 179 -130 D-V 145 -128 P-J 175 -126 E-U 134 -123 O-K 118 -102 F - T 228 -121 N - L 266 -187 G-S 51 -136 *`WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn responsibility for the design of the single Truss depicted on the TDD only, under TPI.1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Mstam, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms areas defined in TPI.1. C;nnvdnht n 2nie A-t Rnnf Tnts. P_ — Renrndnnlinn of thie dnniment. in anv form. is nmhihiied withmrt ihe. wdHe.n nermissinn of A-1 Rnnf Tmcse�. �r _, ,y 2692 ARMSSMB I B01 � SPEC (8" 1 I V✓ �V�V } Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " 16'1 V14 SEAT LPLATE REQ. C 16'11"14 1-1-6-3 1616"6 Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL• 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0,18 Wind Duration: 1.60 Lumber Top chord 2x4 SP 2400f-2.OE T2 2x4 SP #2; Bot chord 2x4 SP #2 B2 2x4 SP M-30; Webs 2x4 SP #3 Rt Bearing Leg: 2x6 SP #2; Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Bracing (a) Continuous lateral restraint equally spaced on member. Puriins In lieu of structural panels or rigid ceiling use puriins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 75 0.20 16.53 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Defl/CSI Criteria ♦ Maximum Reactions (Ibs) PP Deflection in loc L/defl L/# Gravity Non -Gravity VERT(LL): 0.087 C 999 360 Loc R+ / R- / Rh / Rw / U / RL 1 810 /- /- /518 /171 /473 VERT(CL): 0.178 C 999 240 HORZ(LL): 0.033 H - - F 688 /- !- /490 /398 /- HORZ(TL): 0.067 H Wind reactions based on MWFRS Creep Factor: 2.0 1 Brg Width = 7.4 Min Req = 1.5 Max TC CSI: 0.676 F Brg Width = 1.5 Min Req = 1.5 Max BC CSI: 0.623 Bearings I & F are a rigid surface. Max Web CSI: 0.726 Bearing I requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Wgt:95.9lbs Chords Tens.Comp. Chords Tens. Comp. VIEW Ver. 19.01.00A.0618.16 A - B 40 0 C - D 5 - 317 B - C 970 -1860 D - E 41 - 289 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. I - H 133 - 653 H - G 1711 -1468 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. B - I 658 - 713 C - G 1167 -1407 B - H 1665 - 755 F - G 515 - 350 H - C 235 - 25 E - F 1950 -1594 "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TOO only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms areas defined in TPI-1. (:nnvdnhtnc 201E A-1 Ronf Tniz a.s — Renroduntinn of this dnraiment. in anv form. is nrohihitnd without the written nnnnieeinn of A-1 Rnnf Tnic�es. III ARMSSMB B02GE GABL I 1 1 2695 Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 10,00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: B Kzt: NA Des Ld: 40.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #3 M10 2x4 SP M-30; Plating Notes All plates are 1.5X3 except as noted. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 104 0.00 16.95 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Additional Notes See STD DETAILS for gable wind bracing requirements. Shim all supports to solid bearing. Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): -0.021 C 999 36 VERT(CL): -0.028 C 999 24 HORZ(LL): -0.031 C - HORZ(TL): 0.037 C Creep Factor: 2.0 Max TC CSI: 0.371 Max BC CSI: 0.975 Max Web CSI: 0.186 Wgt: 165.2 Ibs VIEW Ver: 19.01.00A.0618.16 ♦ Maximum Reactions (Ibs), or *=PLF Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL N* 88 /- /- /59 /34 /28 Wind reactions based on MWFRS N Brg Width = 203 Min Req = - Bearing X is a rigid surface. Bearing X requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-13 47 0 G- H 55 - 331 B - C 72 - 543 H - 1 44 - 265 C - D 99 - 577 I - J 33 -199 D-E 72 -451 J -K 23 -108 E-F 67 -404 K-L 9 -19 F - G 45 - 334 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp X-W 62 -3 S-R 2 0 W-V 667 -128 R-Q 2 0 V-U 668 -128 Q-P 2 0 U-T 668 -128 P-O 2 0 T-S 668 -128 O-N 2 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp B - Y 626 -132 AF-AG 13 -24 W - Y 139 - 616 AG- R 138 -124 Y-Z 35 -90 AH-AI 9 -21 Z - V 492 -183 AI- Q 140 -124 AA -AB 19 -14 AJ-AK 6 -17 AB- U 28 -106 AK- P 195 -131 AC -AD 18 -33 AL -AM 2 -11 AD- T 157 -127 AM- O 180 - 95 AE-AF 13 -24 AN-M 2 -10 Maximum Gable Forces Per Ply (Ibs) Gables Tens.Comp. Gables Tens. Comp X- B 63 -224 1-AJ 138 -123 Y - C 33 -131 J -AL 191 -129 D -AA 289 -152 K -AN 186 - 98 E -AC 89 -114 M - L 40 - 21 F -AE 145 -124 M - N 48 -24 H -AH 138 -123 -WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TOD only, under TPI-I. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI.1. The approval of the TDD and any Feld # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BBC]) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Cnnvnnhf (c 2016 A-1 in anv fnnn. iz nrnhibifnn withnnr the written nannitsion of A-1 Rnnf T.—c C01 I HIPS 1.y 1 y fi_ 2562 Loading Criteria (psf) TOLL: 20.00 TCDL: 10.00 BOLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " 258# 1# 191# 197 258# r 7'0"12 - 2' 19-1 4 2' t 7'0"12 1' 1 5"9 ,i Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP M-30 T2 2x6 SP 2400f-2.OE; Bot chord 2x4 SP 2400f-2.0E Webs 2x4 SP #3 Special Loads ----(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TO: From 62 pif at -1.46 to 62 pif at 7.00 TO: From 31 pif at 7.00 to 31 plf at 14.00 TO: From 62 plf at 14.00 to 62 plf at 22.46 BC: From 20 plf at 0.00 to 20 pif at 7.00 BC: From 10 pif at 7.00 to 10 plf at 14.00 BC: From 20 plf at 14.00 to 20 plf at 21.00 TO: 258 lb Conc. Load at 7.06,13.94 TO: 191 lb Conc. Load at 9.06,10.50,11.94 BC: 509 lb Conc. Load at 7.00,14.00 BC: 131 lb Conc. Load at 9.06,10.50,11.94 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TO 24 7.00 14.00 BC 79 0.04 20.96 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. 06X6 "X6 C D 20'11" r- 2 0"12 1, 5"4 174 2 0"12 -� 509# 131 131# 131 509# Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Varies by Ld FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.101 H 999 36 ,*-RT(CL): 0.201 H 999 24 HORZ(LL): 0.041 G - HORZ(TL): 0.082 G Creep Factor: 2.0 Max TO CSI: 0.443 Max BC CSI: 0.993 Max Web CSI: 0.321 Wgt: 94.5 Ibs VIEW Ver: 20.01.01A.0724.11 1'5"9 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 2058 /- /- /- /888 /- E 2058 /- /- /- /888 /- Wind reactions based on MWFRS B Big Width = 3.5 Min Req = 1.7 E Big Width = 3.5 Min Req = 1.7 Bearings B & E are a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - B 39 - 26 D - E 1685 - 3948 B - C 1685 - 3952 E - F 39 - 26 C - D 1462 - 3462 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - H 3465 -1462 G - E 3462 -1462 H - G 3430 -1460 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. H - C 834 - 58 D - G 844 - 58 C-G 35 -3 -WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (Too) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristen, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St, Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Convnnht 0 2 1r A-1 Rnnf Tnicans - Rnnmduntinn of this don rnent in nnv Monis nrohihifnd withnut the written rw msion of A-1 Rnnf Tnixses. _' 1 AR'MSSM13 CO2 iivao iyp, HIPS 2710 M _O V 4:3 1'5"9 i 9' Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: 11 EXP: B Kzt: NA Des Ld: 40.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 it Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP M-30 Webs 2x4 SP #3 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 9.00 12.00 BC 120 0.04 20.96 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. 3' a5X6 1112X4 =5X6 D E F 20'11" 21' 9' 1'5"9 Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 2017 RES PP Deflection in loc L/defl L/# Gravity Non -Gravity TPI Sid: 2014 VERT(LL): 0.073 J 999 360 Loc R+ / R- / Rh / Rw / U / RL B 952 /- /- /572 /372 /161 Rep Factors Used: Yes VERT(CL): 0.146 J 999 240 FT/RT:10(0)/10(10) HORZ(LL): 0.023 C - H 952 /- /- /572 /372 /- Plate Type(s): HORZ(TL): 0.045 C Wind reactions based on MWFRS WAVE Creep Factor: 2.0 B Brg Width = 3.5 Min Req = 1.5 Max TC CSI: 0.741 H Brg Width = 3.5 Min Req = 1.5 Max BC CSI: 0.682 Bearings B & H are a rigid surface. Max Web CSI: 0.233 Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. Wgt: 92.4 Ibs A- B 39 0 E- F 444 - 948 VIEW Ver: 19.01.00A.0618.16 B - C 554 -1371 F - G 473 -1092 C - D 473 -1092 G - H 554 -1371 D- E 444 - 948 H- I 39 0 Wind Wind loads based on MWFRS with additional C&C member design. Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - J 1157 - 356 J - H 1157 - 368 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C-J 251 -310 J-G 251 -310 E - J 613 - 227 **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing JDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Krislam, P.E. responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field 488906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms areas defined in TPI-1. (:nnwinht n 20tfi A-i Rnnf Tmsses — RenrnAurtinn of This Anniment in anv form. i.e nrohihitarl Wihout the written nermincion of A-1 Ronf Tninses ARMSSMB "rr� CO3 COMN 10 I r1y 2752 ,t: Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " Lumber Top chord 2x4 SP 42 Bot chord 2x4 SP M-30 Webs 2x4 SP #3 Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.04 20.81 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. 10'6" i 10'5"8 Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Wind Wind loads based on MWFRS with additional C&C member design. D=4X4 =DAD `zf1in 20'1 V8 Dell/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.040 G 999 36 VERT(CL): 0.081 G 999 24 HORZ(LL): 0.016 G - HORZ(TL): 0.033 G Creep Factor: 2.0 Max TC CSI: 0.426 Max BC CSI: 0.630 Max Web CSI: 0.250 Wgt: 93.8 Ibs VIEW Ver: 19.01.00A.0618.16 3X4(A1) 1 y'7 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 949 /- /- /565 /190 /164 F 864 /- /- /485 /163 /- Wind reactions based on MWFRS B Big Width = 3.5 Min Req = 1.5 F Big Width = 3.5 Min Req = 1.5 Bearings B & F are a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A- B 39 0 D- E 438 -1072 B - C 549 -1434 E - F 568 -1426 C-D 419 -1073 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - G 1234 -415 G - F 1224 -411 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - G 278 - 389 G - E 280 - 378 D-G 631 -159 -WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI.1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. (:nnvrinht n 20ia A-1 Rnnf Tri., es — Renrndnrtinn of this d—inn nr. in anv fnrrn. is nrnhihiled withnnt tha writtan ins-i sin. of A-1 R-f Tmesat. I MONO 2749 Loading Criteria (pst) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " SEAT PLATE REQ. 7'10"8 �— 1'5"9 --{ Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwail: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP M-30 Bot chord 2x4 SP #2 Webs 2x4 SP #3 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 93 0.15 7.88 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. C Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 2017 RES PP Deflection in loc L/defl L/# Gravity Non -Gravity TPI Std: 2014 VERT(LL): 0.015 F 999 360 Loc R+ / R- / Rh / Rw / U / RL B 424 /- /- /393 /136 /236 Rep Factors Used: Yes VERT(CL): 0.021 F 999 240 FT/RT:10(0)/10(10) HORZ(LL): 0.008 F - - E 219 /- !- /265 /94 /- Plate Type(s): HORZ(TL): 0.011 F D 93 /- /- /48 /90 /- WAVE Creep Factor: 2.0 Wind reactions based on MWFRS Max TC CSI: 0.184 B Brg Width = 8.0 Min Req = 1.5 Max BC CSI: 0.573 E Brg Width = - Min Req = - Max Web CSI: 0.137 D Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Wgt: 35.0 Ibs Bearing B requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) VIEW Ver: 19.01.00A.0618.16 Chords Tens.Comp. Chords Tens. Comp. A-B 39 0 C-D 42 -135 B - C 165 - 351 Wind Wind loads based on MWFRS with additional C&C member design. Left bottom chord exposed to wind. Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B- F 286 -406 F- E 0 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. C - F 462 - 324 **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ('BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerm responsibility for the design of the single Truss depicted on the TDD only, under TPI-I. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. (;onvnnht n 20tfi AA Roof TnicsP_s — Renroduotion of ihi[ do-mentin anv fond is nrohihited without the written nerrni-inn of A-1 Roof Tniacea. ARMSSMB 11- yPG D02GE GABL 1 y 11y 1271,9 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #3 E-1-5"9--- Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: it EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 it Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Plating Notes All plates are 1.5X3 except as noted. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 75 0.15 8.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Additional Notes See STD DETAILS for gable wind bracing requirements. F co LO -v v Defl/CSI Criteria ♦ Maximum Reactions (Ibs), or *=PLF PP Deflection in loc L/defl L/# Gravity Non -Gravity VERT(LL): -0.000 E 999 360 Loc R+ / R- / Rh / Rw / U / RL B 213 J- /- /157 /55 /239 VERT(CL): 0.001 E 999 240 HORZ(LL): -0.001 E - G* 73 /- /- /49 /39 /- HORZ(TL): 0.002 E - Wind reactions based on MWFRS Creep Factor: 2.0 B Brg Width = 8.0 Min Req = 1.5 Max TC CSI: 0.307 G Brg Width = 88.0 Min Req = - Max BC CSI: 0.057 Bearings B & B are a rigid surface. Max Web CSI: 0.045 Bearings B & B require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Wgt:40.6lbs Chords Tens.Comp. Chords Tens. Comp. VIEW Ver: 19.01.00A.0618.16 A - B 39 0 D - E 29 - 202 B - C 37 - 346 E - F 23 - 64 C - D 41 - 288 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B-J 13 -21 1 - H 3 -7 J-1 7 -12 H-G 0 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. F -G 119 -52 Maximum Gable Forces Per Ply (Ibs) Gables Tens.Comp. Gables Tens. Comp. C - J 132 - 87 E - H 300 -139 D-I 182 -126 **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ('BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (Le. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI-I. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. (:nnvdnht n 2016 A-1 Rnnf Tnissas - Rnnrnd-tinn of this donnmentin anv fnnnis nrohihiind vrithm 1 thn wditan nermissinn of A-1 Rnnf Tnicsna. /yPc �,rr��//I/GUGV f I A MSSMB I HJ7 I HIP�y _ 2 (� ty I 2557 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP M-30 Webs 2x4 SP #3 N -84 265# 1 141#y -- 2'8"11 --{ 101 E-- 1'11"13 -{ 9110"1 Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 GCpi: 0.18 Wind Duration: 1.60 Special Loads ----(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 0 plf at -1.98 to 61 pif at -0.10 TC: From 2 pif at -0.10 to 2 pif at 9,84 BC: From 2 plf at 0.00 to 2 plf at 9.84 TC: -8 lb Conc. Load at 1.46 TC: 141 lb Conc. Load at 4.29 TC: 265 lb Conc. Load at 7.12 BC: 20 lb Conc. Load at 1.46 BC: 105 lb Conc. Load at 4.29 BC: 185 lb Conc. Load at 7.12 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 116 0.15 9.84 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. �- 1'5"8 �-- 2'9"1529"15 -1 20# 105# 185# Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 2017 RES PP Deflection in loc L/defl L/# Gravity Non -Gravity TPI Std: 2014 VERT(LL): 0.026 F 999 360 Loc R+ / R- / Rh / Rw / U / RL Rep Factors Used: Varies by Ld C li�RT(CL): 0.062 F 999 240 B 360 /- /- !- /235 /- FT/RT:10(0)/10(10) HORZ(LL): 0.011 F - - E 378 /- /- /- /132 /- Plate Type(s): HORZ(TL): 0.026 F D 66 /- /- /- /59 /- WAVE Creep Factor: 2.0 Wind reactions based on MWFRS Max TC CSI: 0.587 B Brg Width = 4.9 Min Req = 1.5 Max BC CSI: 0.736 E Brg Width = 1.5 Min Req = - Max Web CSI: 0.292 D Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Wgt: 39.2 Ibs Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. VIEW Ver: 20.01.01A.0724.11 A-B 19 -13 C -D 51 -69 B - C 394 - 548 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B-F 538 -352 F -E 0 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. C - F 382 - 584 "WARNING'" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranev Kristam, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPIA. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI.1. r:nnvdnht n 2n1A A-1 Rnnf T.-- R"nrndnrfion of this dnnimnntin anv fnnn. is nrnhihifnd wifl, I the wdf ,n nnnnission of AA Rnnf Tni-s ARMSSMB Ji- (JACK —Y I I ly 11—V 4 1 /272 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Purlins 4"3 1 Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 12 0.04 1.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. W 12 C 6[% 2X4(A1) B �— 1, ---� �— 1'5"9 —� Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Wind Wind loads based on MWFRS with additional C&C member design. o IUD 9. Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): NA VERT(CL): NA HORZ(LL): -0.000 D HORZ(TL): 0.000 D Creep Factor: 2.0 Max TC CSI: 0.346 Max BC CSI: 0.041 Max Web CSI: 0.000 Wgt: 5.6 Ibs VIEW Ver: 19.01.00A.0618.16 i Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 198 /- /- /177 /99 /56 D 10 /-7 /- /19 /14 /- C - /-21 A /34 /35 /- Wind reactions based on MWFRS B Big Width = 3.5 Min Req = 1.5 D Big Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens, Comp. A-B 39 0 B-C 44 -24 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. B-D 0 0 "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Mslam, P.E. responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. r:nnvdnht n 2016 A-1 Rnnf Tnitar_s — Ranrnd"ntinn of IhN dncnnnsnt in anv fom, is nmhihited ath-1 the wnftnn nnrmissinn of A-1 Rnnf Tniavas. JVY '-ARMSSMB J3 r .. ryp. JACK 41 y y 2737 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 T3_ 4 IV �- 1'5"9 Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Purlins In lieu of structural panels or rigid ceiling use puriins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 36 0.04 3.00 Apply puriins to any chords above or below fillers at 24" OC unless shown otherwise above. Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Wind Wind loads based on MWFRS with additional C&C member design. 9N C T co 0 _r r LO r CV Defl/CSI Criteria ♦ Maximum Reactions (Ibs) PP Deflection in loc L/defl L/# Gravity Non -Gravity VERT(LL): NA Loc R+ / R- / Rh / Rw / U / RL B 234 /- !- /181 /87 /109 VERT(CL): NA HORZ(LL): 0.001 D D 53 /- 1- /29 /- 1- HORZ(TL): 0.002 D C 70 /- /- /39 /58 /- Creep Factor: 2.0 Wind reactions based on MWFRS Max TC CSI: 0.389 B Brg Width = 3.5 Min Req = 1.5 Max BC CSI: 0.082 D Brg Width = 1.5 Min Req = - Max Web CSI: 0.000 C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Wgt: 11.2 Ibs Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. VIEW Ver: 19.01.00A.0618.16 A -B 39 0 B-C 32 -89 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. B-D 0 0 ..WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ('BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TOD and any field 488906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. r;nowinht f)c 201E A-1 Ronf Tmc - Ranrorl-Am of this donimentin anv forme, nrohihitod without the written nanoic ion of A-1 Roof Tojee- ARMSSMB J5J� ( JACK'YN� y 11'y I moo,, t,cvcv 256P Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 T C 115119 I_ 51 i 1 Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 GCpi: 0.18 Wind Duration: 1.60 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 60 0.04 5.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT.10(0)/10(10) Plate Type(s): WAVE Wind Wind loads based on MWFRS with additional C&C member design. Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): NA VERT(CL): NA HORZ(LL): 0.006 D HORZ(TL): 0.011 D Creep Factor: 2.0 Max TC CSI: 0.344 Max BC CSI: 0.263 Max Web CSI: 0.000 Wgt: 18.2 Ibs VIEW Ver: 20.01.01A.0724.11 1 O ZN `— I In ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 308 /- /- /224 /99 /161 D 92 /- /- /50 /- /- C 133 /- /- /79 /108 /- Wind reactions based on MWFRS B Brg Width = 3.5 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-B 39 0 B-C 59 -108 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. B-D 0 0 ..WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedri responsibility for the design of the single Truss depicted on the TDD only, under TPI-i. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pmnav KNstam, P.E. responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI.1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. C.nnvnnht n 2016 A-1 Rnof Tnm.-- Rnnrnd,,dinn of Ihlc dnnimnntin anv fnnnis nrohihMel wilhnut thn waft- nemiavinn of A-1 Rnnf T­ J7 EJAC yfj- —y y 5 1 2554 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Purlins T 115n9 + 7' Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 GCpi: 0.18 Wind Duration: 1.60 In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 75 0.04 7.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)!10(10) Plate Type(s): WAVE Wind Wind loads based on MWFRS with additional C&C member design. Deft/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): NA VERT(CL): NA HORZ(LL): 0.017 D HORZ(TL): 0.034 D Creep Factor: 2.0 Max TC CSI: 0.744 Max BC CSI: 0.533 Max Web CSI: 0.000 Wgt: 23.8 Ibs VIEW Ver: 20.01.01A.0724.11 C A Maximum Reactions (Ibs) Gravity Loc R+ / R- / Rh Non -Gravity /Rw /U IRL B 386 /- /- /271 /114 /213 D 131 !- /- /74 /- /- C 191 A /- /116 /155 /- Wind reactions based on MWFRS B Brg Width = 3.5 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp, Chords Tens. Comp. A-B 39 0 B-C 86 -138 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. B -D 0 0 *'WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ('BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. (:nnvrinht n 2tlta A-7 Rnnf Tni.¢se+_c- R"nrnrlu Jinn of Ihic rinnimnnt. in mnv form. iA nmhihited without the written nernitsinn of A-1 Rnnf Tnracec. JUNE 20, 2019 TYPICAL HIP / KING JACK CONNECTION I STDTL01 'A A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 CORNERSET GENERAL SPECIFICATIONS MAX LOAD: 55 psf Roof Load, 175 mph, ASCE 7-10, Exp. B, C up to 60' Mean Roof Height and Exposure D up to 30' Mean Roof Height. Attach End Jack's w/ (4) 16d Toe Nails @ TC & (3) 16d Toe Nails @ BC Attach King Jack w/ (3) 16d Toe ,Nails @ TC & BC Attach Corner Jack's w/ (2) 16d Toe Nails @ TIC & 2E BC (Typ) 0 —1 r1- %M ttach Corner Jack's il (2) 16d Toe Nails @ TC & BC (Typ) Rama Pranav Kristam, P.E. # 88906 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 FEBRUARY 17, 2017 1 ALTERNATE GABLE END BRACING DETAIL STDTL03 ALTERNATE DIAGONAL BRACING TO THE BOTTOM CHORD HORIZONTAL BRACE (SEE SECTION A -A) TRUSSSES 24. O.C. A-1 ROOF TRUSSES 4451 ST. LUCIE SLVD. - FORT PIERCE, FL 34948 772-409-1010 1'-3'MAX. \ DIAG. BRACE AT 1/3 POINTS IF NEEDED IT IS THE RESPONSIBILITY OF THE BLDG. DESIGNER OR THE PROJECT ENGINEER/ARCHITECT \ TO DESIGN THE CEILING DIAPHRAGM AND ITS ATTACHMENT TO THE TRUSSES TO RESIST ALL OUT OF PLANE LOADS THAT MAY RESULT FROM THE BRACING OF THE GABLE ENDS. END WALL 2X6 DIAGONAL BRACE SPACED 4B' O.C. ATTACHED TO VERTICAL WITH (4) - 16d NAILS, AND ATTACHED TO BLOCKING WITH (5) - 10d COMMONS. NAIL DIAGONAL BRACE TO PURLIN WITH TWO 16d NAILS. 2X4 PURLIN FASTENED TO FOUR TRUSSES WITH (2) - 16d NAILS EACH. FASTEN PURLIN TO BLOCKING W/ (2) - 16d NAILS (MIN.). PROVIDE 2X4 BLOCKING BETWEEN THE TRUSSES SUPPORTING THE BRACE AND THE TWO TRUSSES ON EITHER SIDE AS NOTED, TOENAIL BLOCKING TO TRUSSES WITH (2) - 10d NAILS AT EACH END. ATTACH DIAGONAL BRACE TO BLOCKING WITH (5) - 10d COMMON WIRE NAILS. CEILING SHEATHING BRACING REQUIREMENTS FOR STRUCTURAL GABLE TRUSSES STRUCTURAL GABLE TRUSSES MAY BE BRACED AS NOTED: METHOD 1: ATTACH A MATCHING GABLE TRUSS TO THE INSIDE FACE OF THE STRUCTURAL GABLE AND FASTEN PER THE FOLLOWING NAIL SCHEDULE. METHOD 2: ATTACH 2X_ SCABS TO THE FACE OF EACH VERTICAL MEMBER ON THE STRUCTURAL GABLE PER THE FOLLOWING NAILING SCHEDULE. SCABS ARE TO BE OF THE SAME SCAB ALONG SIZE, GRADE, AND SPECIES AS THE TRUSS VERTICALS. VERTICAL NAILING SCHEDULE: - FOR WIND SPEEDS 120 MPH (ASCE 7-98, 02, 05), 150 MPH (ASCE 7-10) OR LESS, NAIL ALL MEMBERS WITH ONE ROW OF 10d (.131' X 3') NAILS SPACED 6' O.C. - FOR WIND SPEEDS GREATER 120 MPH (ASCE 7-98, 02, 05), 150 MPH (ASCE 7-10) NAIL ALL MEMBERS WITH TWO ROWS OF 10d (.131'X3') NAILS SPACED 6' O.C. (2X4 STUDS MINIMUM). STRUCTURAL/ GABLE TRUSS MAXIMUM STUD LENGTHS ARE LISTED ON PAGE 1. ALI BRACING METHODS SHOWN ON PAGE 1 ARE VALID AND ARE TO BE FASTENED TO THE SCABS OR VERTICAL STUDS OF THE STANDARD GABLE TRUSS ON THE INTERIOR SIDE OF THE STRUCTURE. NOTE: THIS DETAIL IS TO BE USED ONLY FOR STRUCTURAL GABLES WITH INLAYED / STUDS. TRUSSES WITHOUT INLAYED \S ARE NOT ADDRESSED HERE. / STANDARD GABLE / TRUSS / UKAL TRUSS ­_ STUD AN ADEQUATE DIAPHRAGM OR OTHER METHOD OF BRACING MUST BE PRESENT TO PROVIDE FULL LATERAL SUPPORT OF THE BOTTOM CHORD TO RESIST ALL OUT OF PLANE LOADS. THE BRACING SHOWN IN THIS DETAIL IS FOR VERTICAL/STUDS ONLY. Rama Pranav Kristam, P.E. # 88906 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 12/23/19 PIGGY -BACK TRUSS STDTL04.1 A-1 ROOF TRUSSES 4451 ST, LUCIE BLVD. FORT PIERCE, FL 34946 772-409.1010 PIGGY -BACK DETAIL (TYPICAL) 180 MPH WIND, 30.00 FT MEAN ROOF HEIGHT, A.S.C.E. 7-10, PARTIALLY ENCLOSED BLDG. LOCATED ANYWHERE AT ROOF, EXPOSURE C, WIND D.L.= 5.0 P.S.F. (MIN.), KZT= 1.00. OR... 160 MPH WIND, 30.00 FT MEAN ROOF HEIGHT, A.S.C.E. 7-10, PARTIALLY ENCLOSED BLDG. LOCATED ANYWHERE AT ROOF, EXPOSURE D, WIND D.L.= 5.0 P.S.F. (MIN.), KZT= 1.00. IMPORTANT NOTE: TOP CHORDS OF TRUSSES SUPPORTING PIGGY -BACK CAP TRUSSES MUST BE ADEQUATELY BRACED BY SHEATHING AND/ OR PURLINS. THE BUILDING ENGINEER OF RECORD SHALL PROVIDE DIAGONAL BRACING OR OTHER SUITABLE ANCHORAGE TO PERMANENTLY RESTRAIN PURLINS AND LATERAL BRACING FOR OUT OF PLANE LOADS OVER GABLE ENDS. MAXIMUM TRUSS SPACING IS NOT TO EXCEED 24" O.C. DETAIL IS NOT APPLICABLE IF CAP SUPPORTS ADDITIONAL LOADS SUCH AS CUPOLA, STEEPLE, CHIMNEY OR DRAG STRUT LOADS. "REFER TO ENGINEER'S SEALED TRUSS DESIGN DRAWINGS FOR PIGGY -BACK AND BASE TRUSS SPECIFICATIONS." PIGGY -BACK TRUSS. (REFER TO ACTUAL TRUSS DESIGN DRAWINGS FOR ADDITIONAL INFORMATION.) 2'-0" MAX OPTION NO. 1 - TEE-LOK 3" x 8" TEE-LOK MULTI -USE CONNECTION PLATES SPACED AT 4'-0" O.C. MAX. PLATES SHALL BE PRESSED INTO PIGGY -BACK TRUSS AT 4'-0" O.C. STAGGERED FROM EACH FACE AND NAILED TO BASE TRUSS WITH 4 EACH 6d (1.5" X 0.099") NAILS IN EACH PLATE TO ACHEIVE MAXIMUM UPLIFT CAPACITY OF 377 LBS AT EACH 3" X 8" TEE-LOK MULTI -USE CONNECTION PLATE (MINIMUM OF 2 PLATES). OPTION NO.2 - APA RATED GUSSET: 8" x 8" x 0-7/16" (MIN.) APA RATED SHEATHING GUSSETS EACH FACE. ATTACH AT 8'-0" O.C. w/ 8 (EACH) 6d COMMON (0.1 13" x 2") NAILS PER GUSSET: 4 (EACH) AT CAP BOTTOM CHORD & 4 (EACH) AT BASE TRUSS TOP CHORD. GUSSETS MAY BE STAGGERED AT 4'-0" O.C. FRONT TO BACK FACES. MINIMUM TWO (2 EA.) CONNECTIONS AT EACH TRUSS. OPTION NO. 3 - 2X4 VERTICAL WOOD SCAB: 2X4 SPF 42, FULL CHORD DEPTH SCABS AT EACH FACE. ATTACH AT 8'-0" O.C. w/6 (EACH) 1 Od BOX NAILS (0.128" x 3") PER SCAB: 3 (EACH) AT CAP BOTTOM CHORD AND 3 (EACH) AT BASE TRUSS TOP CHORD. SCABS MAY BE STAGGERED 4'-0" O.C. FRONT TO BACK FACES. MINIMUM TWO (2 EA.) CONNECTIONS AT EACH TRUSS. OPTION #1: TEE-LOK MULTI -USE CONNECTION PLATE. OPTION #2: APA RATED GUSSET. OPTION #3: 2X4 VERT. SCAB. ATTACH EACH PURLIN TO TOP CHORD OF BASE TRUSS. PURLIN & CONNECTIONS BY OTHERS. BASE TRUSS. (REFER TO TRUSS DESIGN DRAWINGS FOR ADDITIONAL INFORMATION.) PURLINS SPACED ACCORDING TO MAX. SPACING OF TOP CHORD OF BASE TRUSS. SPACING IS NOT TO EXCEED 24" O.C. & PURLINS TO BE LOCATED AT JOINT OF EACH BASE TRUSS. ** IMPORTANT NOTE ** THIS DETAIL IS VALID ONLY FOR SINGLE PLY BASE TRUSSES SPACED AT 24" O.C. OR LESS. Rama Pranav Kristam, P.E. # 88906 4451 St. Lucie Blvd, Suite 201 JULY 17, 2017 I TRUSSED VALLEY SET DETAIL - SHEATHED I STDTL05 GENERAL SPECIFICATIONS: .W 1. NAIL SIZE = 3" X 0.131" = 10d 2. WOOD SCREW = 4.5" SDS25412 SIMPSON OR EQUIVALENT. 3. INSTALL SHEATHING TO TOP CHORD OF BASE TRUSSES. 4. INSTALL VALLEY TRUSSES (24" O.C. MAXIMUM) AND SECURE TO BASE TRUSSES AS PER DETAIL "A". rw 5. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIDUAL DESIGN DRAWINGS. A-1 ROOF TRUSSES 6. NAILING DONE PER NDS - 01. 4451 ST. LUCIE BLVD, GABLE END, COMMON 7. VALLEY STUD SPACING NOT TO EXCEED 48" O.C. FORT PIERCE, FL 34946 TRUSS, OR GIRDER 772-409-1010 TRUSS VALLEY T(TYPRCUS J/ AL) 11 II I ti () II II 'iASE TR; SSES -t tNU, I,VMMVr4 3S, OR GIRDER TRUSS TRUSS CRITERIA: SECURE VALLEY TRUSS WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH W/ ONE ROW OF 10d WIND DESIGN PER ASCE 7-10: 170 MPH NAILS 6" O.C. MAX MEAN ROOF HEIGHT = 30 FEET ROOF PITCH = MINIMUM 3112 MAXIMUM 6/12 CATERGORY 11 BUILDING EXPOSURE C WIND DURATION OF LOAD INCREASE: 1.60 MAX TOP CHORD TOTAL LOAD = 50 PSF ATTACH 2X4 CONTINUOUS #2 MAX SPACING = 24" O.C. (BASE AND VALLEY) SYP TO THE ROOF W/ TWO MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES. SIMPSON SDS25412 (1/4" X 4.5") OR EQUIVALENT WOOD SCREWS INTO EACH BASE TRUSS. »IMAM Rama Pranav Kristam, P.E. # 88906 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 FEBRUARY 5, 2018 1 TRUSSED VALLEY SET DETAIL a % A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772409-1010 SECURE W/( VALLEY TRUSS (TYPICAL) GABLE END, COMMON TRUSS, OR GIRDER TRUSS (NO SHEATHING) N.T.S. GENERAL SPECIFICATIONS: 1. NAIL SIZE = 3" X 0.131" = 10d 2. WOOD SCREW = 3" SDS25300 SIMPSON OR EQUIVALENT. 3. INSTALL VALLEY TRUSSES (24" O.C. MAXIMUM) AND SECURE PER DETAIL "A" 4. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIUAL DESIGN DRAWINGS. 5. BASE TRUSS SHALL BE DESIGNED WITH A PURLIN SPACING EQUIVALENT TO THE RAKE DIMENSION OF THE VALLEY TRUSS SPACING. 6. NAILING DONE PER NDS - 01. 7. VALLEY STUD SPACING NOT TO EXCEED 48" O.C. BASE TRUSSES WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH WIND DESIGN PER ASCE 7-10: 170 MPH MAX MEAN ROOF HEIGHT = 30 FEET ROOF PITCH = MINIMUM 3/12 MAXIMUM 6/12 CATERGORY II BUILDING EXPOSURE C WIND DURATION OF LOAD INCREASE: 1.60 ATTACH 2X4 CONTINUOUS #2 MAX TOP CHORD TOTAL LOAD = 50 PSF SYP TO THE ROOF W/ TWO MAX SPACING = 24" O.C. (BASE AND VALLEY) SIMPSON SDS25300 (1/4" X 3") MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES. OR EQUIVALENT WOOD SCREWS INTO EACH BASE TRUSS. Rama Pranav Kristam, P.E. # 88906 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 ULY 17, 2017 I (HIGH WIND VELOCITY) I STDTL07 A-1 ROOF TRUSSES 4451 ST, LUCIE BLVD. FORT PIERCE, FL 34946 772409-1010 ATTAC WIND DESIGN PER ASCE 7-98, ASCE 7-I WIND DESIGN PER ASCE 7-10: 170 MPF MAX MEAN ROOF HEIGHT = 30 FEET CATERGORY If BUILDING EXPOSURE B OR C WIND DURATION OF LOAD INCREASE:' MAX TOP CHORD TOTAL LOAD = 50 PSI MAX SPACING = 24" O.C. (BASE AND VA SUPPORTING TRUSSES DIRECTLY UNDER V/i i 1 R 0O IVIUO I oc DESIGNED WITH A MAXIMUM UNBRACED LENGTH OF 2' - 10" ON AFFECTED TOP CHORDS. NOTES: 1. SHEATHING APPLIED AFTER INSTALLATION OF VALLEY TRUSSES. 2. THIS DETAIL IS NOT APPLICABLE FOR SPF-S SPECIES LUMBER. FOR BEVELED BOTTOM CHORD, CLIP MAY BE APPLIED TO EITHER FACE. CLIP MAY BE APPLIED TO THIS FACE UP TO A NON -BEVELED MAXIMUM 6/12 PITCH BOTTOM CHORD H I NON -BEVELED BOTTOM CHORD CLIP MUST BE APPLIED TO THIS FACE WHEN PITCH EXCEEDS 6/12 (MAXIMUM 12/12 PITCH) Ooe Rama Pranav Kdstam, P.E. # 88906 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 FEBRUARY 17, 2017 STANDARD GABLE END DETAIL h. STDTL08 q A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 TYPICAL 2X4 L-BRACE NAILED TO 2X4 VERTICALS W/10d NAILS, 6' D.C. VERT STUD SECTION B-B TRUSS GEOMETRY AND CONDITIONS SHOWN ARE FOR ILLUSTRATION ONLY. VERTICAL 2X6 SP OR SPF STUDPEBRACE #2 DIAGONAL BRACE (4) - 16d NAILS16d NAILS SPACED 6' O.C. (2) 10d NAILS INTO 2X62X6 SP OR SPF #2 2X4 SP OR SPF #2L HORIZONTAL NAILED TO RTICALS SECTION A -A W/(4) - 10d NAILS DIAGONAL BRACE 4' - 0' O.C. MAX. SEE INDIVIDUAL ENGINEERING DRAWINGS FOR TRUSS DESIGN CRITERIA. 12 PROVIDE 2X4 BLOCKING BETWEEN Q VARIES TO COMMON TRUSS THE FIRST TWO TRUSSES AS NOTED. TOENAIL BLOCKING TO TRUSSES * WITH (2) - 10d NAILS AT EACH END. ATTACH DIAGONAL BRACE TO BLOCKING WITH (5) - lOd NAILS (4) Bd NAILS MINIMUM, ROOF B 3X4= PLYWOOD SHEATHING TO r SHEATHING 2X4 STD SPF BLOCK * DIAGONAL BRACING ** L - BRACING REFER REFER TO SECTION A -A TO SECTION B-B 24' MAX.--I-�—► ) NOTE:. / / / MINIMUM GRADE OF #2 MATERIAL IN THE TOP AND BOT HAND lOd RTOM USS CONNECTION BETWEEN BOTTOM CHORD OF GABLE END WALL TO 12, MAX. AILS BE PROVIDED BY PROJECT ENGINEER OR ARCHITECT. 3. BRACING SHOWN IS FOR INDIVIDUAL TRUSS ONLY. CONSULT BLDG. --, ARCHITECT OR ENGINEER FOR TEMPORARY AND PERMANENT BRACING OF ROOF SYSTEM. 4. 'L' BRACES SPECIFIED ARE TO BE FULL LENGTH, SPF OR SP #3 OR / BETTER WITH ONE ROW OF 10d NAILS SPACED 6' O.C. o/ TRUSSES @ 24' O.C. 5. DIAGONAL BRACE TO BE APPROXIMATELY 45 DEGREES TO ROOF DIAPHRAGM AT4'-0'D.C. 6. CONSTRUCT HORIZONTAL BRACE CONNECTING A 2X6 AND A 2X4 AS SHOWN 2X6 DIAGONAL BRACE WITH 16d NAILS SPACED 6' O.C. HORIZONTAL BRACE TO BE LOCATED AT SPACED 48' O.C. ATTACHED THE MIDSPAN OF THE LONGEST GABLE STUD. ATTACH TO VERTICAL GABLE TO VERTICAL WITH (4) - STUDS WITH (3) 10d NAILS THROUGH 2X4 (REFER TO SECTION A -A) - 16d NAILS, AND ATTACHED 7. GABLE STUD DEFLECTION MEETS OR EXCEEEDS L/240. TO BLOCKING WITH (5) - B. THIS DETAIL DOES NOT APPLY TO STRUCTURAL GABLES. DIAL. BRACE 10d NAILS. 9. DO NOT USE FLAT BOTTOM CHORD GABLES NEXT TO SCISSOR TYPE AT 1/3 POINTS TRUSSES. IF NEEDED 10. 10d AND 16d NAILS ARE 0.131'X3.0' AND 0.131'X3.5' COMMON WIRE NAILS N:7 HORIZONTAL BRACE RESPECTIVELY. (SEE SECTION A -A) 11. SOUTHERN PINE LUMBER DESIGN VALUES ARE THOSE EFFECTIVE 06-01-12 BY SPIB/ALSC. MINIMUM STUD SIZE SPECIES AND GRADE STUD SPACING WITHOUT BRACE 2X4 L - BRACE DIAGONAL BRACE (2) DIAGONAL BRACES AT 1/3 POINTS MAXIMUM STUD LENGTH 2X4 SP 43 / STUD 12" O.C. 3-8-10 5.6.11 6-6-11 11.1-13 2X4 SP #31 STUD 16" O.C. 3-3.10 4-9.12 6-6.11 9-10.15 2X4 SP 43 / STUD 24" O.C. 2.8-6 3.11-3 54-12 8-1.2 2X4 SP #2 12" O.C. 3-10.15 5.6.11 6-6.11 11-8.14 2X4 SP #2 16" O.C. 3-6.11 4-9-12 6-6.11 10.8-0 2X4 SP #2 24" O.C. 3.1-4 3.11-3 1 6-2-9 9-3.13 DIAGONAL BRACES OVER 6' - 3' REQUIRE A 2X4 T-BRACE ATTACHED TO ONE EDGE. DIAGONAL BRACES OVER 12' - 6' REQUIRE 2X4 I -BRACES ATTACHED TO BOTH EDGES. FASTEN T AND I BRACES TO NARROW EDGE OF DIAGONAL BRACE WITH 10d NAILS 6' O.C., WITH 3' MINIMUM END DISTANCE. BRACE MUST COVER 90% OF DIAGONAL LENGTH. T OR I BRACES MUST BE 2X4 SPF #2 OR SP #2. END WALL MAX MEAN ROOF HEIGHT = 30 FEET EXPOSURE B OR C — ASCE 7.10 190 MPH STUD DESIGN IS BASED ON COMPONENTS AND CLADDING, DURATION OF LOAD INCREASE :1.60 CONNECTION OF BRACING IS BASED ON MWFRS. Rama Pranav Kristam, P.E. # 66906 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 FEBRUARY 17, 2017 I T WITH 2XIBRACE ONLY -BRACE DETAIL N Y'L ( STDTL09 NOTES: T-BRACING / I -BRACING TO BE USED WHEN CONTINUOUS LATERAL BRACING IS IMPRACTICAL. T-BRACE / I -BRACE MUST COVER 90% OF WEB LENGTH. THIS DETAIL NOT TO BE USED TO CONVERT T-BRACE / I -BRACE WEBS TO CONTINUOUS LATERAL BRACED WEBS. A-1 ROOF TRUSSES 4451 ST, LUCIE BLVD, FORT PIERCE, FL 34946 772-409-1010 NAILING PATTERN T-BRACE SIZE NAIL SIZE NAIL SPACING 2X4 OR 2X6 OR 2X8 10d 6" O.C. NOTE: NAIL ALONG ENTIRE LENGTH OF T-BRACE / I -BRACE (ON TWO-PLY TRUSSES NAIL TO BOTH PLIES) NAILS BRACE SIZE FOR ONE -PLY TRUSS SPECIFIED CONTINUOUS ROWS OF LATERAL BRACING WEB SIZE 1 2 2X3 OR 2X4 2X4 T-BRACE 2X4 I -BRACE 2X6 2X6 T-BRACE 2X6 I -BRACE 2X8 2X8 T-BRACE 2X8 I -BRACE BRACE SIZE FOR TWO-PLY TRUSS SPECIFIED CONTINUOUS ROWS OF LATERAL BRACING WEB SIZE 1 2 2X3 OR 2X4 2X4 T-BRACE 20 I -BRACE 2X6 2X6 T-BRACE 2X6 I -BRACE 2X8 2X8 T-BRACE 2X8 I -BRACE T-BRACE / I -BRACE MUST BE SAME SPECIES AND GRADE (OR BETTER) AS WEB MEMBER. NAILS WEB NAILS NAILS WEB SECTION D E T A I L Sme Pranav Kdstam, P.E. #! 88906 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 FEBRUARY 17, 2017 LATERAL BRACING RECOMMENDATIONS I STDTL10 A_1 ROOF TRUSSES 4451 ST, LUCIE BLVD. FORT PIERCE, FL 34946 772 409-1010 TO MINIMIZE VIBRATION COMMON TO ALL SHALLOW FRAMING SYSTEMS, 2X6 'STRDNGBACK' IS RECOMMENDED, LOCATED EVERY B TO 10 FEET ALONG A FLOOR TRUSS. NOTE 1: 2X6 STRONGBACK ORIENTED VERTICALLY MAY BE POSITIONED DIRECTLY UNDER THE TOP CHORD OR DIRECTLY ABOVE THE BOTTOM CHORD, SECURELY FASTENED TO THE TRUSS USING ANY OF THE METHODS ILLUSTRATED BELOW. NOTE 2: STRONGBACK BRACING ALSO SATISFIES THE LATERAL BRACING REQUIREMENTS FOR THE BOTTOM CHORD OF THE TRUSS WHEN IT IS PLACED ON TOP OF THE BOTTOM CHORD, IS CONTINUOUS FROM END TO END, CONNECTED WITH A METHOD OTHER THAN METAL FRAMING ANCHOR, AND PROPERLY CONNECTED, BY OTHERS, AT THE ENDS. USE METAL FRAMING ANCHOR TO ATTACH TO TOP CHORD BLOCKING BEHIND THE VERTICAL WEB IS RECOMMENDED WHILE NAILING THE STRONGBACK INSERT WOOD SCREW THROUGH OUTSIDE FACE OF CHORD INTO EDGE OF STRONGBACK (DO NOT ATTACH TO VERTICAL ATTACH TO VERTICAL USE DRYWALL TYPE SCREWS) WEB WITH (3) - 10d SCAB WITH (3) - 10d NAILS (0.131' X 3') NAILS (0.131' X 3'). r ATTACH TO VERTICAL NIBS(0.131WITH (3)X3) ATTACH 2X4 VERTICAL TO FACE OF TRUSS. FASTEN TO TOP AND BOTTOM CHORD WITH (2) - 10d NAILS (0.131' X 3') IN EACH CHORD USE METAL FRAMING J ATTACH TO VERTICAL L ATTACH TO VERTICAL ANCHOR TO ATTACH WEB WITH (3) - 10d SCAB WITH (3) - 10d TO BOTTOM CHORD NAILS (0.131' X 3') NAILS (0.131' X 3') TRUSS 2X6 4' - 0' WALL STRONGBACK (TYPICAL SPLICE) (BY OTHERS) ATTACH TO CHORD WITH (2) #12 X 3' WOOD SCREWS (0.216' OIAJ INSERT SCREW THROUGH OUTSIDE FACE OF CHORD INTO EDGE OF STRONGBACK (DO NOT USE DRYWALL TYPE SCREWS) THE STRONGBACKS SHALL BE SECURED AT THEIR ENDS TO AN ADEQUATE SUPPORT, DESIGNED BY OTHERS. IF SPLICING IS NECESSARY, USE A 4' - 0' LONG SCAB CENTERED ON THE SPLICE AND JOINED WITH (12) - 10d NAILS (0.131' X 3') EQUALLY SPACED. ALTERNATE METHOD OF SPLICING: OVERLAP STRONGBACK MEMBERS A MINIMUM OF 4' - 0' AND FASTEN WITH (12) - 10d NAILS (0.131' X 3') STAGGERED AND EQUALLY SPACED (TO BE USED ONLY WHEN STRONGBACK IS NOT ALIGNED WITH A VERTICAL). BLOCKING (BY OTHERS) Rama Pranav Kristam, P.E. # 88906 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 FEBRUARY17,2017 1 LATERAL TOE -NAIL DETAIL I STDTLII A-1 ROOF TRUSSES 4451 ST, LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 NOTES: 1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 45° WITH THE MEMBER AND MUST HAVE FULL WOOD SUPPORT (NAIL MUST BE DRIVEN THROUGH AND EXIT AT THE BACK CORNER OF THE MEMBER END AS SHOWN). 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THE TWO SPECIES FOR MEMBERS OF DIFFERENT SPECIES. TOE -NAIL SINGLE SHEAR VALUES PER NOS 2001 (LB/NAIL) DIA SP OF HF SPF SPF-S .131 88.0 80.6 69.9 68.4 59.7 o .135 93.5 85.6 74.2 72.6 63.4 J ;n .162 108.8 99.6 86.4 84.5 73.8 .128 74.2 67.9 5B.9 57.6 50.3 c� .131 75.9 69.5 60.3 59.0 51.1 Z 0 J .148 81.4 74.5 64.6 63.2 52.5 in N M VALUES SHOWN ARE CAPACITY PER TOE -NAIL. APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED. EXAMPLE: (3) - 16d NAILS (0.162' DIA. X 3.5') WITH SPF SPECIES BOTTOM CHORD FOR LOAD DURATION INCREASE OF 1.15: 3 (NAILS) X 84.5 (LB/NAIL) X 1.15 (DOL) = 291.5 LB MAXIMUM CAPACITY ANGLE MAY VARY FROM 30' TO 60° 45.00' ANGLE MAY VARY FROM 30° TO 60° THIS DETAIL IS ONLY APPLICABLE TO THE THREE END DETAILS SHOWN BELOW. VIEWS SHOWN ARE FOR ILLUSTRATION PURPOSES ONLY. SIDE VIEW (2X3) 2 NAILS NEAR SIDE NEAR SIDE SIDE VIEW (2X4) 3 NAILS NEAR SIDE -°I NEAR SIDE NEAR SIDE 45.00' SIDE VIEW (20) 2 NAILS NEAR SIDE NEAR SIDE NEAR SIDE NEAR SIDE ANGLE MAY VARY FROM 30° TO 60° 45.000 P.E. # 88906 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 FEBRUARY 17, 2017 1 UPLIFT TOE -NAIL DETAIL ( STDTL12 V s. A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD, FORT PIERCE, FL 34946 772A09-1010 THIS DETAIL SHALL BE USED FOR A CONNECTION RESISITING UPLIFT FORCES ONLY. BUILDING DESIGNER IS RESPONSIBLE FOR LOADS IN OTHER DIRECTIONS. TOE —NAIL WITHDRAWAL VALUES PER NOS 2005 (LB/NAIL) DIA. SP OF HF SPF SPF—S L7 .131 59 46 32 30 20 z O J .135 60 48 33 30 20 Ln .162 72 58 39 37 25 J _ .128 54 42 28 27 19 F O LO Z OJ .131 55 43 29 28 19 LU .148 62 48 34 31 21 —I L0 J N Q � Z .120 51 39 27 26 17 CD Z .128 49 38 26 25 17 O .131 51 39 27 26 17 `j O .148 57 44 31 28 20 NOTES: 1. TOE —NAILS SHALL BE DRIVEN AT AN ANGLE OF 30° WITH THE MEMBER AND STARTED 1/3 THE LENGTH OF THE NAIL FROM THE MEMBER END AS SHOWN. 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. ALLOWABLE VALUE SHALL BE BASED ON THE SPECIE WITH LOWER NAIL CAPACITY BETWEEN THE TWO MEMBERS IN THE CONNECTION. VALUES SHOWN ARE CAPACITY PER TOE —NAIL. APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED. EXAMPLE: (3) — 16d NAILS (0162' DIA. X 3.5') WITH SPF SPECIES TOP PLATE FOR WIND DOL OF 1.33: 3 (NAILS) X 37 (LB/NAIL) X 1.33 (DOL FOR WIND) = 148 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WIND FOR WIND DOL OF 1.60: 3 (NAILS) X 37 (LB/NAIL) X 1.60 (DOL FOR WIND) = 177 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WIND IF THE UPLIFT REACTION SPECIFIED ON THE TRUSS DESIGN DRAWING EXCEEDS 147 LEIS (177 LBS) BUILDING DESIGNER IS RESPONSIBLE TO SPECIFY A DIFFERENT CONNECTION. rrr USE (3) TOE —NAILS ON 2X4 BEARING WALL rr+e USE (4) TOE —NAILS ON 2X6 BEARING WALL NEAR SIDE FAR S' )E TOP PLATE OF WALL VIEWS SHOWN ARE FOR ILLUSTRATION PURPOSES ONLY [L NAIL NAIL Rama Pranev Kristam, P.E. END VIEW #eB06 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 SIDE VIEW IWO-11-MWAMWOR TYP 2x2 NAILER ATTACHMENT I STDTLI3 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 1.0 x 4 2x2 NAILER ATTACHMENT GENERAL SPECIFICATIONS MAX LOAD: 55 psf Roof Load, 170 mph, ASCE 7-10, 29'-0" Mean Height, Exp. B, C or D. Rama Pranav Kristam, P.E. # 88906 4451 St. Lucie Blvd, Suite 201 April 11, 2016 I TYPICAL ALTERNATE BRACING DETAIL I STDTLI4 FO EXTERIOR FLAT GIRDER TRUSS A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 am TRUSS 2411 O.C. UPLIFT CONNECTION (SEE ROOF TRUSS) 12 VARIES MAX 3011(2'-611) 2x6 #2 SP (Both Faces) 2411 O.C. SIMPSON H5 Rama Pranav Kristam, P.E. # 88906 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 FEBRUARY 17, 2017 I STANDARD REPAIR DETAIL FOR BROKEN CHORDS, WEBS, AND I STDTL15 DAMAGED OR MISSING CHORD SPLICE PLATES A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34W 772-409-1010 TOTAL NUMBER OF NAILS EACH SIDE OF BREAK * X (INCHES) MAXIMUM FORCE (LBS) 15% LOAD DURATION SIP OF SPF HF 2X4 2X6 2X4 2X6 2X4 2X6 2X4 2X6 2X4 2X6 20 30 24" 1706 2559 1561 2342 1320 1980 1352 2028 26 39 30" 2194 3291 2007 3011 1697 2546 1738 2608 32 48 36" 2681 4022 2454 3681 2074 3111 2125 3187 38 57 42" 3169 4754 2900 4350 2451 3677 2511 3767 44 66 48" 3657 5485 3346 5019 2829 4243 2898 4347 +� DIVIDE EQUALLY FRONT AND BACK ATTACH 2X_ SCAB OF THE SAME SIZE AND GRADE AS THE BROKEN MEMBER TO EACH FACE OF THE TRUSS ( CENTER ON BREAK OR SPLICE) WITH 10d NAILS (TWO ROWS FOR 2X4, THREE ROWS FOR 2X6) SPACED 4' O.C. AS SHOWN (.131' DIA. X 3'). STAGGER NAIL SPACING FROM FRONT FACE AND BACK FACE FOR A NET 2' O.C. SPACING IN THE MAIN MEMBER. USE A MIN. 3' MEMBER ENO DISTANCE. THE LENGTH OF THE BREAK (C) SHALL NOT EXCEED 12'. (C=PLATE LENGTH FOR SPLICE REPAIRS) THE MINIMUM OVERALL SCAB LENGTH REQUIRED (L) IS CALCULATED AS FOLLOWS: L = (2) X + C " 10d NAILS NEAR SIDE + 10d NAILS FAR SIDE THE LOCATION OF THE BREAK MUST BE GREATER THE REQUIRED X DIMENSION FROM ANY PERIMETER AND A MINIMUM OF 5' FROM ANY INTERIOR JOINT DO NOT USE REPAIR FOR JOINT SPLICES NOTES: 1. THIS REPAIR DETAIL IS TO BE USED ONLY FOR THE APPLICATION SHOWN. THIS REPAIR DOES NOT IMPLY THAT THE REMAINING PORTION OF THE TRUSS IS UNDAMAGED. THE ENTIRE TRUSS SHALL BE INSPECTED TO VERIFY THAT NO FURTHER REPAIRS ARE REQUIRED. WHEN THE REQUIRED REPAIRS ARE PROPERLY APPLIED, THE TRUSS WILL BE CAPABLE OF SUPPORTING THE LOADS INDICATED. 2. ALL MEMBERS MUST BE RETURNED TO THEIR ORIGINAL POSITIONS BEFORE APPLYING REPAIR AND HELD IN PLACE DURING APPLICATION OF REPAIR. 3. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 4. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO AVOID LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES. S. THIS REPAIR IS TO BE USED FOR SINGLE PLY TRUSSES IN THE 2X_ ORIENTATION ONLY. G. THIS REPAIR IS LIMITED TO TRUSSES WITH NO MORE THAN THREE BROKEN MEMBERS. 81 TRUSS CONFIGURATION AND BREAK LOCATIONS FOR ILLUSTRATIONS ONLY THAN OR EQUAL TO BREAK OR HEEL JOINT (SEE SKETCH ABOVE). Rama Pranav Mstam, P.E. # 88906 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 FEBRUARY 17, 2017 1 SCAB APPLIED OVERHANGS ( STDTLI6 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 30M 772-409-1010 TRUSS CRITERIA: LOADING: 40-10-0-10 DURATION FACTDR: 1.15 SPACING: 24' O.C. TOP CHORD: 2X4 OR 2X6 PITCH: 4/12 - 12/12 HEEL HEIGHT: STANDARD HEEL UP TO 12' ENERGY HEEL END BEARING CONDITION MIMS 1. ATTACH 2X SCAB (MINIMUM #2 GRADE SPF, HF, SP, OF) TO ONE FACE OF TRUSS WITH TWO ROWS OF 10d COMMON WIRE NAILS (.148' OIA. X 3') SPACED 6' O.C. 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO AVOID LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES. 2X SC NOTE: TRUSS BUILT WITHOUT AN OVERHANG. THIS DETAIL IS NOT TO BE USED WHEN OVERHANG HAS BEEN BROKEN OFF. THIS DETAIL TO BE USED ONLY WITH TRUSSES (SPANS LESS THAN 409 SPACED 24' O.C. MAXIMUM AND HAVING PITCHES BETWEEN 4/12 AND 12/12 AND TOTAL TOP CHORD LOADS NOT EXCEEDING 50 PSF. TRUSSES NOT FITTING THESE CRITERIA SHOULD BE EXAMINED INDIVIDUALLY. REFER TO INDIVIDUAL TRUSS DESIGN FOR PLATE SIZES AND LUMBER GRADES Rama Pranav Kdstam, P.E. # 88906 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946