Loading...
HomeMy WebLinkAboutEnergy CodesI , 7 FORM 60OA-97 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: SAVANNA CLUB PLAN Al TOP Builder: Address: Permitting Office: City, State: PORT ST LUCIE, FL Permit Number: Owner: " RICH PROPERTIES Jurisdiction Number: Climate Zone: Central 1. New construction or existing 2. Single family or multi -family 3. Number of units, if multi -family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Glass area & type a. Clear - single pane b. Clear - double pane c. Tint/other SC/SHGC - single pane d. Tint/other SC/SHGC - double pane 8. Floor types a. Slab -On -Grade Edge Insulation b. N/A c. N/A 9. Wall types a. Concrete, hit Insul, Exterior b. Concrete, Int Insul, Adjacent c. N/A d. N/A e. N/A 10. Ceiling types a. Under Attic b. N/A c. N/A 11. Ducts a. Sup: Con. Ret: Con. AH: Interior b. N/A New _ 12. Cooling systems Multi -family _ a. Central Unit 1 . 1 _ b. N/A Yes _ 894 ft2 c. N/A Cap: 21.5 kBtu/hr SEER: 10.00 54.0 ft2 _ 13. Heating systems 0.0 ft2 _ a. Electric Strip Cap: 17.0 kBtu/hr _ 0.0 ft2 _ COP: 1.00 _ 0.0 ft2 b. N/A R=0.0, 98.0(p) ft _ c. N/A _ 14. Hot water systems _ a. Electric Resistance Cap: 30.0 gallons R=3.0, 450.0 ft2 _ EF: 0.89 R=3.0, 304.5 ft2 _ b. N/A _ c. Conservation credits _ (HR-Heat recovery, Solar _ DHP-Dedicated heat pump) R=19.0, 894.0 ft2 _ 15. HVAC credits _ (CF-Ceiling fan, CV -Cross ventilation, HF-Whole house fan, _ PT -Programmable Thermostat, Sup. R=4.2, 30.0 ft _ RB-Attic radiant barrier, MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.06 Total as -built points: 10811.00 PASS Total base points: 11611.00 I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code., PREPARED BYAliyel:44. F.ES A 'r.�r' DATE: �Z.. ' I hereby certify that this t uilding, as designed, Iis in compliance with the Florida E r G de. OWNER/AGENT: . DATE: ;712 19 _ Review of the plans and ST 9T�0. specifications covered by this indicates yob € calculation compliance ..��'°� with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 •CODS Florida Statutes. wE BUILDING OFFICIAL: DATE: FORM 60OA-97 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs s^ Residential Whole Building Performance Method A Project Name: SAVANNA CLUB PLAN Al TOP Builder: Address: Permitting Office: City, State: PORT ST LUCIE, FL Permit Number: Owner: RICH PROPERTIES Jurisdiction Number: Climate Zone: Central 1. New construction or existing New _ 12. Cooling systems 2. Single family or multi -family Multi -family _ a. Central Unit .3. Number of units, if multi -family 1 _ 4. Number of Bedrooms 1 _ b. N/A 5. Is this a worst case? Yes _ 6. Conditioned floor area (ft2) 894 ft2 c. N/A 7. Glass area & type _ a. Clear - single pane 54.0 ft2 _ 13. Heating systems b. Clear - double pane 0.0 ft2 _ a. Electric Strip C. Tint/other SC/SHGC - single pane 0.0 ft2 _ d. Tint/other SC/SHGC - double pane 0.0 ft2 b. N/A 8. Floor types ' _ a. Slab -On -Grade Edge Insulation R=0.0, 98.0(p) ft _ c. N/A b. N/A c. N/A 14. Hot water systems 9. Wall types _ a. Electric Resistance r a. Concrete, Int Insul, Exterior R=3.0, 450.0 W _ b. Concrete, Int Insul, Adjacent R=3.0, 304.5 ft2 _ b. N/A c. N/A _ d. N/A _ c. Conservation credits e. N/A (HR-Heat recovery, Solar 10. Ceiling types _ DHP-Dedicated heat pump) a. Under Attic R=19.0, 894.0 ft2 _ 15. HVAC credits b. N/A _ (CF-Ceiling fan, CV -Cross ventilation, c. N/A HF-Whole house fan, 11. Ducts _ PT -Programmable Thermostat, a. Sup: Con. Ret: Con. AH: Interior Sup. R=4.2, 30.0 ft _ RB-Attic radiant barrier, b. N/A MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.06 Total as -built points: 10811.00 PASS Total base points: 11611.00 I hereby certify that the plans and specifications covered bythis calculation are in compliance with the Florida Energy Code. PREPARED BYE ded- 4 F,-'S DATE: - I hereby certify that this building, as desigried,-is in compliance with the Florida`-C` r ' Cede. OWNER/AGENT: % DATE: S a� Cap: 21.5 kBtu/hr _ SEER 10.00 Cap: 17.0 kBtu/hr COP: 1.00 Cap: 30.0 gallons _ EF: 0.89 _ Review of the plans and 4zKE ST,9? specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: EnergyGauge® (Version: FLRCNA-200) FORM 60OA-97 - SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , PORT ST LUCIE, FL, PERMIT #: BASE AS -BUILT GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points .18 894.0 42.08 6771.1 Single, Clear E 1.0 5.5 27.0 59.31 0.96 1543.6 Single, Clear E 1.0 5.5 20.0 59.31 0.96 ' 1143.4 Single, Clear S 1.0 4.3 7.0 44.66 0.88 274.5 As -Built Total: 54.0 2961.4 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adajcent 304.5 0.7 213.1 Concrete, Int Insul, Exterior 3.0 450.0 1.40 630.0 Exterior 450.0 1.90 855.0 Concrete, Int Insul, Adjacent 3.0 304.5 0.70 213.1 Base Total: 754.5 1068.1 As -Built Total: 754.5 843.2 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 21.0 1.60 33.6 Adjacent Wood 21.0 2.40 50.4 Exterior 0.0 0.00 0.0 Base'Total: 21.0 33.6 As -Built Total: 21.0 50.4 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Under Attic 894.0 0.60 536.4 Under Attic 19.0 894.0 1.10 983.4 Base Total: 894.0 536.4 As -Built Total: 894.0 983.4 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 98.0(p) -31.8 -3116.4 Slab -On -Grade Edge Insulation 0.0 98.0(p) -31.90 -3126.2 Raised 0.0 .0.00 0.0 Base Total: -3116.4 As -Built Total: -3126.2 INFILTRATION Area X BSPM = Points Area X SPM = Points •, 894.0 14.31 12793.1 894.0 14.31 12793.1 Stammer Base Points: 18086.0 Summer As -Built Points: 14505.3 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points 14505.3 1.000 1 0.930 0.341 1.000 4600.1 18086.0 0.3577 6469.4 14505.3 1.00 0.930 0.341 1.000 4600.1 EnergyGaugeT" DCA Form 60OA-97 FORM 60OA-97 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , PORT ST LUCIE, FL, PERMIT #: BASE AS -BUILT GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Points .18 894.0 4.79 770.7 Single, Clear E 1.0 5.5 27.0 9.96 1.01 271.6 Single, Clear E 1.0 5.5 20.0 9.96 1.01 201.2 Single, Clear S 1.0 4.3 7.0 7.73 1.04 56.5 As -Built Total: 64.0 529.3 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adajcent 304.5 1.8 548.1 Concrete, Int Insul, Exterior 3.0 450.0 3.80 1710.0 Exterior 450.0 2.00 900.0 Concrete, Int Insul, Adjacent 3.0 304.5 2.30 700.3 Base Total: 754.5 1448.1 As -Built Total: 754.5 2410.4 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 21.0 4.00 84.0 Adjacent Wood 21.0 5.90 123.9 Exterior 0.0 0.00 0.0 Bas#Total: 21.0 84.0 As -Built Total: 21.0 123.9 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Under Attic 894.0 0.60 536.4 Under Attic 19.0 894.0 1.00 894.0 Base Total: 894.0 536.4 As -Built Total: 894.0 894.0 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 98.0(p) -1.9 -186.2 Slab -On -Grade Edge Insulation 0.0 98.0(p) 2.50 245.0 Raised 0.0 , 0.00 0.0 Base Total: -186.2 As -Built Total: 245.0 . INFILTRATION Area X BWPM = Points Area X WPM = Points 894.0 -0.28 -250.3 894.0 -0.28 -250.3 Winter Base Points: 2402.7 Winter As -Built Points: 3952.3 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points 3952.3 1.000 0.930 1.000 1.000 3675.6 2402.7 1.0730 2578.1 3952.3 1.00 0.930 1.000 1.000 3675.6 EnergyGaugeTM DCA Form 60OA-97 FORM 60OA-97 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS: , PORT ST LUCIE, FL, PERMIT #: BASE AS -BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 1 2564.00 2564.0 30.0 0.89 1 1.00 2535.19 1.00 2535.2 As -Built Total: 2536.2 CODE COMPLIANCE STATUS BASE AS -BUILT Cooling + Heating + Points Points Hot Water Points = Total Points Cooling Points + Heating + Hot Water = Total Points Points Points 6469.4 2578.1 2664.0 11611.5 FZ00.1 3675.6 2535.2 10810.9 PASS s EnergyGaugeTm DCA Form 60OA-97 FORM 60OA-97 0 Code Compliance Checklist Residential Whole Building Performance Method A - Details l I ADDRESS: , PORT ST LUCIE, FL, PERMIT #: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area. Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility penetrations; between'wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from and is sealed to the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from conditioned space, tested. Multi -story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity, between floors. Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, ., have combustion air. RA-22 nTI4FR PRFSCRIPTIVF MFARI IRFS lmm0 hp mpt nr pYcppriprl by all rpc11dpnr_Ps_1 CO IVIPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit breaker electric or cutoff as must be provided. External or built-in heat trap required. Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 aallons per minute at 80 PSIG. Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls 1607.1, Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1, 602.1 Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. V 0 EnergyGaugeTm DCA Form 60OA-97 EneigyGauge®/FlaRES'97 FLRCNA-200 - ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD a ESTIMATED ENERGY PERFORMANCE SCORE* = 84.1 �1 . The higher the score, the more efficient the home. RICH PROPERTIES,, PORT ST LUCIE, FL, 1. New construction or existing New _ 12. Cooling systems 2. Single family or multi -family Multi -family _ a. Central Unit Cap: 21.5 kBtu/hr 3. Number of units, if multi -family 1 _ SEER 10.00 _ 4. Number of Bedrooms I _ b. N/A _ 5. Is this a worst case? Yes 6. Conditioned floor area (W) 894 ftZ c. N/A 7. Glass area & type a. Clear - single pane 54.0 ftz _ 13. Heating systems b. Clear - double pane 0.0 ftz _ a. Electric Strip Cap: 17.0 kBtu/hr c. Tintlother SC/SHGC - single pane 0.0 ftz _ COP: 1.00 _ d. Tint/other SC/SHGC - double pane 0.0 ftz b. N/A 8. Floor types _ a. Slab -On -Grade Edge Insulation R=0.0, 98.0(p) ft _ c. N/A b. N/A c. N/A 14. Hot water systems 9. Wall types _ a. Electric Resistance Cap: 30.0 gallons _ a. Concrete, Int Insul, Exterior R=3.0, 450.0 ftz _ EF: 0.89 _ b. Concrete, Int Insul, Adjacent R=3.0, 304.5 ft2 _ b. N/A _ c. N/A d. N/A _ c. Conservation credits _ e. N/A (HR-Heat recovery, Solar 10. Ceiling types _ DIP -Dedicated heat pump) a. Under Attic R=19.0, 894.0 ftz _ 15. HVAC credits _ b. N/A _ (CF-Ceiling fan, CV -Cross ventilation, c. N/A HF-Whole house fan, 11. Ducts _ PT -Programmable Thermostat, a. Sup: Con. Ret: Con. AH: Interior Sup. R=4.2, 30.0 ft _ RB-Attic radiant barrier, b. N/A W-C-Multizone cooling, W-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: f Address of New Home: Date: City/FL Zip: *NOTE. The home's estimated energy performance score is only available through the FLARES computer program. This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPADOE EnergyStarTmdesignation), your home may qualms for energy efficiency mortgage (EE4 incentives ifyou obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 4071638-1492 or see the Energy Gauge web site at www.fsec. ucf edu for information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 8501487-1824. EnergyGauge® (Version: FLRCNA-200) } RIGHT-J LOAD AND EQUIPMENT SUMMARY Entire House FES, INC. Job: 01089 4121199 34 N.W. 168TH. STREET, NORTH MIAMI BEACH, FL 33169 Phone: 305-653-0212 Fax: 305-653-0232 For: SAVANNA CLUB PLAN Al TOP FL, FL Phone: WC=e • Notes: Weather: Fort Lauderdale, FL, US Winter. Design Conditions Outside db 46 OF Inside db 71 OF Design TD 25 OF Heating Summary Building heat loss 9451 Btuh ` Ventilation air 0 cfm Ventilation air loss 0 Btuh Design heat load 9451 Btuh r Infiltration Method Simplified Construction quality Average Fireplaces 0 Heating Cooling Area (ftZ) 894 894 Volume (ft3) 8046 8046 Air changes/hour 1.2 0.5 Equiv. AVF (cfm) 161 67 Heating Equipment Summary Make n/a Trade n/a Efficiency Heating input Heating output Heating temp rise Actual heating fan Heating air flow factor Space thermostat 100.0 EFF 0 Btuh 0 Btuh 0 OF 430 cfm 0.046 cfm/Btuh Summer Design Conditions Outside db 91 OF Inside db 75 OF Design TD 16 OF Daily range M Relative humidity 50 % Moisture difference 60 gr/lb Sensible Cooling Equipment Load Sizing Structure 9934 Btuh Ventilation 880 Btuh Design temperature swing 3.0 OF Use mfg. data n Rate/swing multiplier 0.96 Total sens. equip. load 10382 Btuh Latent Cooling Equipment Load Sizing Internal gains 460 Btuh Ventilation 2032 Btuh Infiltration 2730 Btuh Total latent equip. load 5223 Btuh Total equipment load 15604 Btuh Cooling Equipment Summary Make Trade Efficiency 0.0 EER Sensible cooling 0 Btuh Latent cooling 0 Btuh Total cooling 0 Btuh Actual cooling fan 430 cfm Cooling air flow factor 0.043 cfm/Btuh Load sensible heat ratio 67 % Printout certified by ACCA to meet all requirements of Manual J 7th Ed. Wr'tgll'7trC:) t Right -Suite Residentiallm 5.0.45 RSR23656 2001-Jul-05 09:11:50 • i9l+C.P� H:\Wrightson LOAD CALCS\SAVANNA CLUB\PLAN Al TOP.rsr Page 1 -6 RIGHT-J WORKSHEET Entire House FES, INC. Job:01089 4/21199 34 N.W. 168TH. STREET, NORTH MIAMI BEACH, FL 33169 Phone: 305-653.0212 Fax: 305-653-0232 MANUAL J: /III La. 1 Name of room Entire House PLAN Al TOP 2 Length of exposed wall 98.0 ft 98.0 ft 3 Room dimensions 10.0 x 89.4 ft 4 Ceiings Condit. Option 9.0 ft d 9.0 ft heat/cool TYPE OF CS HTM Area Load (Btuh) Area Load (Btuh) Area Area EXPOSURE NO. Htg Cig (fn Htg - Clg (ft� Htg Cig Htg Cig Htg Cig 5 Gross a 14B 3.6 1.8 477 - `"'* 477 Exposed b 12C 2.3 1.8 81 - - 81 walls and c 13N 1.4 0.6 326 - - 326 partitions d 13C 0.9 1.0 0 '*'" - 0 e 0.0 0.a 0 - - 0 f 0.0 0.0 01 - "" 0 6 Windows and a 1B 26.1 '" 54 1411 "" 54 1411 glass doors b 8B 26.1 - 0 0 ""' 0 0 - Heating c 0.0 " 0 0 0 0 - d 0.0 " 0 0 "" 0 0- e 0.0 - 0 0 "" 0 0- f 0.0 0 0 "" 0 0 7 Windows and North 27.8 15 "" 410 15 "**' 410 glass doors NE/NW 0.0 0 '*" 0 0 - 0 Cooling ENV 85.8 39 `"'* 3367 39 "" 3367 SE/SW 0.0 0 *"" 0 0 "" 0 South 0.0 0 '*'" 0 0 "" 0 Horz 0.0 0 ""' 0 0 "" 0 8 Other doors a 10D 11.5 9.0 21 242 189 21 242 189 b 10A 14.0 11.0 0 0 0 0 0 0 c 0.0 0.0 0 0 0 0 0 0 9 Net a 14B 3.6 1.8 450 1620 797 450 1620 797 exposed b 12C 2.3 1.8 54 122 95 54 122 95 walls and c 13N 1.4 0.6 305 438 197 305 438 197 partitions d 13C 0.9 1.0 0 0 0 0 0 0 e 0.0 0.0 0 0 0 0 0 0 f 0.0 0.0 0 0 0 0 0 0 10 Ceilings a 16D 1.3 2.1 894 1185 1895 894 1185 1895 b 0.0 0.0 0 0 0 0 0 0 c 0.0 0.0 0 0 0 0 0 0 d 0.0 0.0 0 0 0 0 0 0 e 0.0 0.0 0 0 0 0 0 0 f 0.0 0.0 0 0 0 0 0 0 11 Floors a 22A 20.3 0.0 0 0 0 0 0 0 (Note: room b 91A 4.8 2.2 0 0 0 0 0 0 perimeter c 0.0 0.0 0 0 0 0 0 0 is displ. d 0.0 0.0 0 0 0 0 0 0 for slab a 0.0 0.0 0 0 0 0 0 0 floors) f 1 0.0 .0.0 0 0 0 0 0 0 121 Infiltration a 59.1 • 15.8 75 4434 1182 751 4434 1182 13 Subtotal loss=6+8..+11+12 ""' 9451 - "" 9451 Less external heating '"" 0 - "*' 0 Less transfer ""' 0 "*' "" 0 14 Duct loss 0% 0 "" 0°/ 0 •++• °/ '•*+ °/ •+"• 15 Total loss = 13+14 '*" 9451 "" "" 9451 16 Int gains: People @ 300 2 - 600 2 "" 600 Appl. @ 1200 1 - 1200 1 "" 1200 17 Subtot RSH. gain=7+8. +12+16 `**' `"*' 9934 "" "" 9934 Less external cooling "" "" 0 "" "" 0 Less transfer "" "*' 0 " ' ""' 0 18 Duct gain 0% - 0 0°/ "*"' 0 °/ '*'* °/ 19 Total RSH gain=(17+18)*PLF 1.00 - 9934 1.00 - 9934 20 Air required (cfm) 4301 430 '**` 430 430 *`*' "" Printout certified by ACCA to meet all requirements of Manual J 7th Ed. wr�gF7tsOfiC Right -Suite Residential'rm 5.0.45 RSR23656 2001-Jul-0509:11:60 ACA HAWrightsoft LOAD CALCS\SAVANNA CLUBIPLAN Al TOP.rsr Page 1 RIGHT-J CALCULATION PROCEDURES A, B, C, D Entire House FES, INC. Job:01089 4121199 34 N.W. 168TH. STREET, NORTH MIAMI BEACH, FL 33169 Phone: 305-653-0212 Fax: 305-653-0232 Procedure A - Winter Infiltration HTM Calculation* 1. Winter infiltration AVF 1.2 ach x 8046 ft3 x 0.0167 = 161 cfm 2. Winter infiltration load 1.1 x 161 cfm x 25 OF Winter TD = 4434 Btuh 3. Winter infiltration HTM 4434 Btuh / 75 ftZ Total window = 59.1 Btuh/ft2 and door area Procedure B - Summer Infiltration HTM Calculation 1. Summer infiltration AVF 0.5 • ,ach x 8046 ft3 x 0.0167 = 67 cfm 2. Summer infiltration load 1.1 x67 cfm x 16 OF Summer TD = 1182 Btuh 3. Summer infiltration HTM 1182 Btuh / 75 ftZ Total window = 15.8 Btuh/ft2 and door area Procedure C - Latent Infiltration.Gain 0.68 x60 gr/lb moist.diff. x 67 cfm = 2730 Btuh Procedure u - tquipment Sizing Loaas 1. Sensible sizing load Sensible ventilation load 1.1 x 50 cfm vent. x 16 OF Summer TD = 880 Btuh Sensible load for structure (Line 19) + 9934 Btuh Sum of ventilation and structure loads = 10814 Btuh Rating and temperature swing multiplier x 0.96 Equipment sizing load - sensible = 10382 Btuh 2. Latent sizing load Latent ventilation load 0.68 x 50 cfm vent. x 60 gr/lb moist.diff. = 2032 Btuh Internal loads = 230 Btuh x 2 people + 460 Btuh Infiltration load from Procedure C + 2730 Btuh Equipment sizing load - latent = 5223 Btuh *Construction Quality is: a No. of Fireplaces is: 0 Bold/italic values have been manually overridden Printout certified by ACCA to meet all requirements of Manual J 7th Ed. k:. 'VVrj9 l'-1it50 FC Right -Suite ResidentialTm 5.0.45 RSR23656 2001-Jul-05 09:11:50 ,C,A H:%Wrightsoft LOAD CALCSISAVANNA CLUBIPLAN Al TOP.rsr Page 1 FORM 60OA-97 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole lu!!q ng Performance Method A Project Name: SAVANNA CLUB PLAN BOTTOM Builder: Address: Permitting Office: City, State: PORT ST LUCIE, FL Permit Number: Owner: RICH PROPERTIES Jurisdiction Number: Climate Zone: Central 1. New construction or existing 2. Single family or multi -family 3. Number of units, if multi -family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Glass area & type a. Clear - single pane b. Clear - double pane c. Tint/other SC/SHGC - single pane d. Tint/other SC/SHGC - double pane 8. Floor types a. Slab -On -Grade Edge Insulation b. N/A c. N/A 9. Wall types a. 'Concrete, Int Insul, Exterior b. Concrete, Int Insul, Adjacent c. N/A d. NUA e. N/A 10. Ceiling types a. N/A b. N/A . c. N/A 11. Ducts a. Sup: Con. Ret: Con. AH: Interior b. N/A New _ 12. Cooling systems Multi -family _ a. Central Unit 1 _ 1 _ b. N/A Yes _ 894 ft2 c. N/A Cap: 21.5 kBtu/hr _ SEER:10.00 54.0 ft2 _ 13. Heating systems 0.0 ft2 _ a. Electric Strip Cap: 17.0 kBtu/hr 0.0 ft2 _ COP: 1.00 0.0 ft2 b. N/A _ R=0.0, 98.0(p) ft _ c. N/A _ 14. Hot water systems _ a. Electric Resistance Cap: 30.0 gallons R=3.0, 450.0 ft2 _ EF: 0.89 _ R=3.0, 304.5 ft2 _ b. N/A _ c. Conservation credits _ (HR-Heat recovery, Solar _ DHP-Dedicated heat pump) _ 15. HVAC credits _ (CF-Ceiling fan, CV -Cross ventilation, HF-Whole house fan, _ PT -Programmable Thermostat, Sup. R=4.2, 30.0 ft _ RB-Attic radiant barrier, MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.06 Total as -built points: 9667.60 PASS Total base points: 10844.00 I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BYA14Wi ai CE'S Tivc. DATE... I hereby certify that this, tilsiidirig, as c43ighed, is in compliance with the Flo7rida,E erg Cody. OWNER/AGENT: DATE: Review of the plans and 4THE S7r4 specifications covered by thisFo calculation indicates compliance�� with the Florida Energy Code. Before construction is completed this building will be.inspected for compliance with Section 553.908 cOD� Florida Statutes. BUILDING OFFICIAL: DATE: FORM 60OA-97 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: SAVANNA CLUB PLAN Al BOTTOM Builder: Address: Permitting Office: City, State: PORT ST LUCIE, FL Permit Number: Owner: RICH PROPERTIES Jurisdiction Number: Climate Zone: Central 1. New construction or existing 2. Single family or multi -family 3. Number of units, if multi -family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ftz) 7. Glass area & type a. Clear - single pane b. Clear - double pane c. Tint/other SC/SHGC - single pane d. Tintlother SC/SHGC - double pane 8. Floor types a. Slab -On -Grade Edge Insulation b. N/A c. N/A 9. Wall types a.'Concrete, Int Insul, Exterior b. Concrete, Int Insul, Adjacent c. N/A d.'N/A e. N/A 10. Ceiling types a. N/A b. N/A c. N/A 11. Ducts a. Sup: Con. Ret: Con. AH: Interior b. N/A New _ Multi -family _ 1 1 _ Yes _ 894 ftz 54.0 ftz _ 0.0 ftz _ 0.0 ftz _ 0.0 ftz R=0.0, 98.0(p) ft _ R=3.0, 450.0 ftz _ R=3.0, 304.5 ftz 12. Cooling systems a. Central Unit b. N/A c. N/A 13. Heating systems a. Electric Strip b. N/A c. N/A 14. Hot water systems a. Electric Resistance b. N/A _ c. Conservation credits (HR Heat recovery, Solar DHP-Dedicated heat pump) _ 15. HVAC credits (CF-Ceiling fan, CV -Cross ventilation, HF-Whole house fan, PT -Programmable Thermostat, Sup. R=4.2, 30.0 ft _ RB-Attic radiant barrier, MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.06 Total as -built points: 9667.60 PASS Total base points: 10844.00 I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: A/`srl adi DATE: hereby certify that this building, -as designed, is in compliance with the Florida, E er_o Code. OWNER/AGENT: DATE: Cap: 21.5 kBtu/hr _ SEER:10.00 _ Cap: 17.0 kBtu/hr COP: 1.00 _ Cap: 30.0 gallons _ EF: 0.89 _ Review of the plans and �Tla STgT specifications covered by this indicates do = _ �10 'P calculation compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 coDyvs' 1 Florida Statutes. BUILDING OFFICIAL: DATE: FORM 60OA-97 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS:, PORT ST LUCIE, FL, PERMIT #: BASE AS -BUILT GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points .18 894.0 42.08 6771.1 Single, Clear E 1.0 5.5 27.0 59.31 0.96 1543.6 Single, Clear E 1.0 5.5 20.0 59.31 0.96 1143.4 Single, Clear S 1.0 4.3 7.0 44.66 0.88 274.5 As -Built Total: 54.0 2961.4 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adajcent 304.5 0.7 213.1 Concrete, Int Insul, Exterior 3.0 450.0 1.40 630.0 Exterior 450.0 1.90 855.0 Concrete, Int Insul, Adjacent 3.0 304.5 0.70 213.1 Base Total: 764.6 1068.1 As -Built Total: 764.5 843.2 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 21.0 1.60 33.6 Adjacent Wood 21.0 2.40 50.4 Exterior 0.0 0.00 0.0 Base.+Total: 21.0 33.6 As -Built Total: 21.0 50.4 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Under Attic 0.0 0.00 0.0 Base Total: 0.0 0.0 As -Built Total: 0.0 0.0 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 98.0(p) -31.8 -3116.4 Slab -On -Grade Edge Insulation 0.0 98.0(p) -31.90 -3126.2 Raised 0.0 0.00 0.0 Base Total: -3116.4 As -Built Total: -3126.2 INFILTRATION Area X BSPM = Points Area X SPM = Points 894.0 14.31 12793.1 894.0 14.31 12793.1 Summer Base Points: 17549.6 Summer As -Built Points: 13521.9 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points 13521.9 1.000 1 0.930 0.341 1.000 4288.2 17549.6 0.3577 6277.5 13521.9 1.00 0.930 0.341 1.000 4288.2 EnergyGaugeTm DCA Form 60OA-97 FORM 60OA-97 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS:, PORT ST LUCIE, FL, PERMIT #: BASE AS -BUILT GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Points .18 894.0 4.79 770.7 Single, Clear E 1.0 5.5 27.0 9.96 1.01 271.6 Single, Clear E 1.0 5.5 20.0 9.96 1.01 201.2 Single, Clear S 1.0 4.3 7.0 7.73 1.04 56.5 As -Built Total: 54.0 529.3 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adajcent 304.5 1.8 548.1 Concrete, Int Insul, Exterior 3.0 450.0 3.80 1710.0 Exterior 450.0 2.00 900.0 Concrete, Int Insul, Adjacent 3.0 304.5 2.30 700.3 Base Total: 764.5 1448.1 As -Built Total: 764.5 2410.4 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 21.0 4.00 84.0 Adjacent Wood 21.0 5.90 123.9 Exterior 0.0 0.00 0.0 Basil Total: 21.0 84.0 As -Built Total: 21.0 123.9 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Under Attic 0.0 0.00 0.0 Base Total: 0.0 0.0 As -Built Total: 0.0 0.0 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 98.0(p) -1.9 -186.2 Slab -On -Grade Edge Insulation 0.0 98.0(p) 2.50 245.0 Raised 0.0 .0.00 0.0 Base Total: -186.2 As -Built Total: 245.0 INFILTRATION Area X BWPM = Points Area X WPM = Points 894.0 -0.28 -250.3 894.0 -0.28 -250.3 Winter Base Points: 1866.3 Winter As -Built Points: 3058.3 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points 3058.3 1.000 0.930 1.000 1.000 2844.2 1866.3 1.0730 2002.6 3058.3 1.00 0.930 1.000 1.000 2844.2 EnergyGaugeTM DCA Form 60OA-97 FORM 60OA-97 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole .Building Performance Method A - Details ADDRESS: , PORT ST LUCIE, FL, PERMIT #: BASE AS -BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 1 2564.00 2564.0 30.0 0.89 1 1.00 2535.19 1.00 2535.2 As -Built Total: 2535.2 CODE COMPLIANCE STATUS BASE AS -BUILT Cooling + Heating + Points Points Hot Water Points = Total Points Cooling Points + Heating + Hot Water = Total Points Points Points 6277.5 2002.6 2564.0 10844.0 4288.2 2844.2 2535.2 9667.6 PASS EnergyGaugeTm DCA Form 60OA-97 FORM 60OA-97 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: , PORT ST LUCIE, FL, PERMIT #: v 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area. Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from and is sealed to the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from conditioned space, tested. Multi -story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, a .I I have combustion air. RA-99 I7Tl4FR PRFSCRIPTIVF MFOSI IRFA /mnsf hp mpf nr aYr_pprlarf by all rpcirlpnr_pc_1 COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit breaker electric or cutoff as must be provided. External or built-in heat trap re wired. Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficient of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1, 602.1 Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. 01 EnergyGaugeTm DCA Form 60OA-97 EnergyGauge®/FlaRES'97 FLRCNA-200 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 84.1 The higher the score, the more efficient the home. 1. New construction or existing 2. Single family or multi -family 3. Number of units, if multi -family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (W) 7. Glass area & type a. Clear - single pane b. Clear - double pane c. Tint/other SC/SHGC - single pane d. Tintlother SC/SHGC - double pane 8. Floor types a. Slab -On -Grade Edge Insulation b. N/A c. N/A 9. Wall types a. Concrete, Int Insul, Exterior b. Concrete, Int. Insul, Adjacent c. N/A d. N/A e. N/A 10. Ceiling types a. N/A b. N/A c. N/A 11. Ducts a. Sup: Con. Ret: Con. AH: Interior b. N/A RICH PROPERTIES,, PORT ST LUCIE, FL, New _ 12. Cooling systems Multi -family _ a. Central Unit 1 _ 1 _ b. N/A Yes _ 894 ft2 c. N/A 54.0 ft2 _ 13. Heating systems 0.0 ft2 _ a. Electric Strip 0.0 ft2 0.0 ft2 b. N/A R=0.0, 98.0(p) ft _ c. N/A 14. Hot water systems _ a. Electric Resistance R=3.0, 450.0 ft2 R=3.0, 304.5 ft2 _ b. N/A _ c. Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pump) _ 15. HVAC credits _ (CF-Ceiling fan, CV -Cross ventilation, HF-Whole house fan, _ PT -Programmable Thermostat, Sup. R=4.2, 30.0 ft _ RB-Attic radiant barrier, MZ-C-Multizone cooling, MZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed basest on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: Cap: 21.5 kBtu/hr SEER: 10.00 Cap: 17.0 kBtu/hr COP: 1.00 Cap: 30.0 gallons _ EF: 0.89 *NOTE. The home's estimated energy performance score is only available through the FLARES computer program. This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPADOE EnergyStar designation), _ your home may qualify for energy eff ciency mortgage (EEM incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 4071638-1492 or see the Energy Gauge web site at www.fsec. ucf edu for information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 8501487-1824. EnergyGauge® (Version: FLRCNA-200) RIGHT-J LOAD AND EQUIPMENT SUMMARY Entire House FES, INC. Job:01089 4121199 34 N.W. 168TH. STREET, NORTH MIAMI BEACH, FL 33169 Phone: 305-653-0212 Fax: 305-653-0232 Project• • For: SAVANNA CLUB PLAN Al TYP., FL Phone: WC=e Notes: Design Information Weather: Fort Lauderdale, FL, US Winter Design Conditions Outside db 46 OF Inside db 71 OF Design TD 25 OF Heating Summary Building heat loss 10251 Btuh Ventilation air 0 cfm Ventilation air loss 0 Btuh Design heat load 10251 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 Heating Cooling Area (ft2) 894 894 Volume (ft3) 8046 8046 Air changes/hour 1.2 0.5 Equiv. AVF (cfm) 161 67 Heating Equipment Summary Make n/a Trade n/a Efficiency Heating input Heating output Heating temp rise Actual heating fan Heating air flow factor Space thermostat 100.0 EFF 0 Btuh 0 Btuh 0 OF 367 cfm 0.036 cfm/Btuh Summer Design Conditions Outside db 91 OF Inside db 75 OF Design TD 16 OF Daily range M Relative humidity 50 % Moisture difference 60 gr/lb Sensible Cooling Equipment Load Sizing Structure 8489 Btuh Ventilation 1320 Btuh Design temperature swing 3.0 OF Use mfg. data n Rate/swing multiplier 0.96 Total sens. equip. load 9416 Btuh Latent Cooling Equipment Load Sizing Internal gains 460 Btuh Ventilation 3048 Btuh Infiltration 2730 Btuh Total latent equip. load 6239 Btuh Total equipment load 15655 Btuh Cooling Equipment Summary Make Trade Efficiency 0.0 EER Sensible cooling 0 Btuh Latent cooling 0 Btuh Total cooling 0 Btuh Actual cooling fan 367 cfm Cooling air flow factor 0.043 cfm/Btuh Load sensible heat ratio 61 % Printout certified by ACCA to meet all requirements of Manual J 7th Ed. wrjghtsoft Right -Suite Residentialn 5.0.45 RSR23656 2001-Jul-0509:06:44 ACCK H:\Wrightsoft LOAD CALCS\SAVANNA CLUB\PLAN Al BOT.rsr Page 1 RIGHT-J CALCULATION PROCEDURES A, B, C, D Entire House FES, INC. Job: 01089 4/21/99 34 N.W. 168TH. STREET, NORTH MIAMI BEACH, FL 33169 Phone: 305-653-0212 Fax: 305-653-0232 Procedure A - Winter Infiltration HTM Calculation* 1. Winter infiltration AVF 1.2 ach x .8046 ft3 x 0.0167 = 161 cfm 2. Winter infiltration load 1.1 x 161 cfm x 25 OF Winter TD = 4434 Btuh 3. Winter infiltration HTM 4434 Btuh / 75 ft2 Total window = 59.1 Btuh/ft2 and door area Procedure B - Summer Infiltration HTM Calculation 1. Summer infiltration AVF 0.5 . ,ach x 8046 ft3 x 0.0167 = 67 cfm 2. Summer infiltration load 1.1 x67 cfm x 16 OF SummerTD = 1182 Btuh 3. Summer infiltration HTM 1182 Btuh / 75 ft2 Total window = 15.8 Btuh/ft2 and door area Procedure C - Latent Infiltration Gain 0.68 x60 gr/lb moist.diff. x 67 cfm = 2730 Btuh Procedure D - Equipment sizing toads 1. Sensible sizing load Sensible ventilation load 1.1 x 75 cfm vent. x 16 OF Summer TD = 1320 Btuh Sensible load for structure (Line 19) + 8489 Btuh Sum of ventilation and structure loads = 9809 Btuh Rating and temperature swing multiplier x 0.96 Equipment sizing load - sensible = 9416 Btuh 2. Latent sizing load Latent ventilation load 0.68 x 75 cfm vent. x 60 gr/lb moist.diff. = 3048 Btuh Internal loads = 230 Btuh x 2 people + 460 Btuh Infiltration load from Procedure C + 2730 Btuh Equipment sizing load - latent = 6239 Btuh *Construction Quality is: a No. of Fireplaces is: 0 Bol0talic values have been manually overridden Printout certified by ACCA to meet all requirements of Manual J 7th Ed. wng htsoft Right -Suite ResidentialTm 5.0.45 RSR23656 2001-Jul-05 09:06:44 AC >, HAWrightsoft LOAD CALCSISAVANNA CLUB\PLAN Al BOT.rsr Page 1 RIGHT-J WORKSHEET Entire House FES, INC. ` Job:01089 4121199 34 N.W.168TH. STREET, NORTH MIAMI BEACH, FL 33169 Phone: 305-653-0212 Fax: 305-653-0232 MANUAL X tm to. 1 Name of room Entire House PALN Al BOT 2 Length of exposed wall 98.0 ft 98.0 ft 3 Room dimensions 10.0 x 89.4 ft 4 Ceiings Condit. Option 9.0 ftl d 9.0 ft heat/cool TYPE OF CST HTM Area Load (Btuh) Area Load (Btuh) Area Area EXPOSURE NO. Htg Clg (ftj Htg Clg (ft� Htg I Clg Htg Clg Htg Clg 5 Gross a 14B 3.6 1.8 477 - "" 477 '"' •"' "" "" "*• '*" Exposed b 12C 2.3 1.8 81 "" "" 81 "'• "" "" "" '•• •"' walls and c 13N 1.4 0.6 326 "•' "'• 326 •`•' •"' '•*' ••'• "" "" partitions d 13C 0.9 1.0 0 "" "" 0 "" "•* "" "" •••' "" e 0.0 0.0 0 - - 0 - 6 Windows and a 16 26.1 " 64 1411 "" 54 1411 "•" "" "" glass doors b 813 26.1 " 0 0 "" 0 0 "" *"• "'• Heating c 0.0 " 0 0 - 0 0 "" •"' "" d 0.0 " 0 0 "" 0 0 "" e 0.0 0 0 "" 0 0 f 0.0 " 0 0 "" 0 0 '"' '"' "'• 7 Windows and North. 27.8 7 "" 195 7 "" 195 glass doors NE/NW 0.0 0 "" 0 0 "" 0 "" •"' Cooling E/W 85.8 47 •'" 4033 47 "" 4033 SE/SW 0.0 0 "" 0 0 "•' 0 South 0.0 0 "" 0 0 "" 0 Horz 0.0 0 "" 0 0 - 0 8 Other doors a 10D 11.5 9.0 21 242 189 21 242 189 b 10A 14.0 11.0 0 0 0 0 0 0 c 0.0 0.0 0 0 0 0 0 0 9 Net a 14B 3.6 1.8 450 1620 797 450 1620 797 exposed b 12C 2.3 1.8 54 122 95 54 122 95 walls and c 13N 1.4 0.6 305 438 197 305 438 197 partitions d 13C 0.9 1.0 0 0 0 0 0 0 e 0.0 0.0 0 0 0 0 0 0 f 0.0 0.0 0 0 0 0 0 0 10 Ceilings a 16D 1.3 2.1 0 0 0 0 0 0 b 0.0 0.0 0 0 0 0 0 0 c 0.0 0.0 0 0 0 0 0 0 d 0.0 0.0 0 0 0 0 0 0 e 0.0 0.0 0 0 0 0 0 0 f 0.0 0.0 0 0 0 0 0 0 11 Floors a 22A 20.3 0.0 98 1985 0 98 1985 0 (Note: room b 91A 4.8 2.2 0 0 0 0 0 0 perimeter c 0.0 0.0 0 0 0 0 0 0 is displ. d 0.0 0.0 0 0 0 0 0 0 for slab a 0.0 0.0 0 0 0 0 0 0 floors) f 0.0 0.0 0 0 0 0 0 0 12 Infiltration a 59.1 15.8 75 4434 11821 75 44341 1182 13 Subtotal loss=6+8„+11+12 "" 10251 "" "" 10251 •`•• '"` "" •'" "" Less external heating •"• 0 "" "" 0 `"' "" "*' •"• "" Less transfer "" 0 "" "" 0 14 Duct loss 0% 0 "" 0°/ 0 ..+. o/ 15 Total loss = 13+14 "" 10251 "" "" 10251 "" "" "" •"" "" 16 Int gains: People @ 300 2 "" 600 2 "•' 600 Appl. @ 1200 1 "" 1200 1 "" 1200 17 Subtot RSH gain=7+8. +12+16 "'• "" 8489 "" '"' 8489 Less external cooling •"' "" 0 "" "" 0 ••" "" "" "" " Less transfer •"' "" 0 "" "" 0 18 Duct gain 0% "" 0 0°/ "" 0 °/ - "" Printout certified by ACCA to meet all requirements of Manual J 7th Ed. wr�g hltsofit Right -Suite Residential"" 5.0.45 RSR23656 2001-Jul-05 09:06:44 55, H:1Wrightsoft LOAD CALCSISAVANNA CLUB%PLAN Al BOT.rsr Page 1