Type R122H First-Stage Regulator
Introduction
The Type R122H is an Underwriters Laboratories listed
regulator designed for Two-Stage LP-Gas systems.
The unit is designed to reduce the tank pressure to an
outlet pressure of 10 psig. The compact size makes it
ideal for small domestic applications and underground
tanks. The outlet pressure setting is nonadjustable
and is factory set at a nominal 10 psig. Screened drip-
lip vents are oriented over the outlet as standard.
Features 41
• 20 Year Recommended Replacement Life-The
R122H is designed using rugged time proven
design concepts and constructed of corrosion Figure 1. Type R122H First-Stage Regulator
resistant materials,both internally and externally.
With proper installation and periodic inspection and Superior Overpressure Protection-The
maintenance the R122H regulator will meet a 20 combination of a high capacity relief valve and large
Year Recommended Replacement Life. vent provide overpressure protection that exceeds
• Dual Gauge Taps-Built-in 118 inch NPT gauge UL standards. When used in conjunction vrith a
taps orificed to a number 54 drill size on both R622 or R652,the two-stage system will limit the
the inlet and outlet side of the regulator allow for downstream pressure from the second-stage to 2
easy testing. psig even in a double failure situation.
• Durability-A fluorocarbon valve disc is utilized Corrosion-Resistant-Added corrosion resistance
to improve lockup performance in systems,,vith from an internal and external coating process for all
contaminated gas. castings prior to painting, stainless steel relief valve
spring and retainer and a corrosion resistant relief
• Improved Regulation-A large fabric-reinforced valve seat.
diaphragm and stabilizer clip deliver accurate and
stable regulation. • Positive Draining Spring Case-When installed
property with the spring case vent pointed down,
• Easy Installation-The units compact size and the design allows moisture formed in the spring
easily accessible inlet and outlet wrench flats make case to drain out limiting the problems with
installation easy even in the tightest installations. corrosion and freezing water in the spring case.
s
a
FISHER EMERSON
Process Management
Bulletin LP-7: R122H
Table 1.Ordering lnibmialfan
TYPE NUMBER CAPACITY STUINR CONNECTIONS NOMINAL OUTLET SETTING
PROPANEIII INLET x OUTLET
R122KAAJ 1.100,000 114-uuh x W-Mch NPT 10 pscg(0.69 bm
1 Cawcdy is based an 30 PSIG(2.07 bar)tMe!prewiro and 20%droop
18-181iPT
SCREENED VENT
1fB.27 NPT
MLETiOUTtET
GAUGE TAPS
NQ"RE97RICTED
PRESSURE TAP
t
tt)
lf2.14 NPT
u4.se tYPT
� a7
n7.>7
o.s� 12
MOUNTING
s
SCREW HOLES
(1n►
Figure 2.Type R 122H Dimensrons UWXES
(nun)
LP-Gas EquIpment
Emerson Process Management
Regulator Technologies.Inc.
USA-HeadglrvWm
MdCirt M.Texas 75069.1872 USA
Telephone:1(800)55SZ853
Telephone:1(972)548-W4
For fut w mfom ation visit www fishetregulators.ctiomilp
The Emmson logo is a um antark and sm ace an d Emerson Efa=Co.Ae amw mum am am propmry d um wom mva owners.FWW is a mak owned tty FWw CaeM ts.Inc..a
busrais d Emerson Proems moupwal
The aartI I I o1 Mb Pkd*Cgn n am; for mk maboaal wapw=arty,and whoa ovary eflon Rae been made to waure mea acuwacy.that►am rat to to awwM ed m■arratoes or
Sttarffitb w expCsss or ft0ytlo4p Ote products or emvroes descrmd 10021 or UNW use or smkab4Rlr.Wa reserve the paM to mo ft or anpnati0 the 0054fts or speciftafto of such
pr00tltts al ally tClte wt3tat rtaCcB.
Emerson Pfooass TAirHpels7erA does rtat asuune eatpons�ly fbr the s eleebort.ease ar asa�esesctoa W any prodttd limpoeu�for pepper aettxvart use and enaaaersaftoe of al+y EmOrsan
Ptaoess marapemard aroold veer Islay V t ft mcnaeer
EM ERSON.
CEmeeeon Procebe ktrnap awd Regulator TecRnoto n,ft..2M.2010;AP RVO Reser td Process Management
Bulletin 71 . 1 -R622
Jane 2010
Type R622 Pressure Reducing Regulator
• Compact Design High Capacity
• Protective Inlet Internal Relief
Screen '
• Light Weight
}
>r
• Inlet and Outlet Pressure Gauge Taps
Figure 1. rype R622 FBiture Reducrny Reguiata
Introduction
Type R622 direct-operated. sprang-loaded regulators applications. These regulators can be used adh
provide economical pressure reducing control in natural.manufactured.or propane gases and have the
a variety of residential.commercial.and industrial same inlet and outlet pressure capabilities.
0
a
a
r
FISHER EMERSON.
Bulletin 71 .1 :R622
Specifications
Body Size and End Connection Style() Pressure Registration
1/2 NPT inlet and outlet Internal
Maximum Allowable Inlet Pressure() Relief Performance
Operating: 125 psig(8,6 bar) See Figure 4
Emergency: 125 psig(8.6 bar)
Except 1.8 to 2.2-inches w.c.(4 to 5 mbar)spring � Internal Relief Performance
range which has operating and emergency Start-to-Discharge is 8 to 22-inches w.c.
pressures of 60 psig{4,1 bar) (20 to 55 mbar)for setpoints from
1.8 to 20-inches w.c.(4 to 50 mbar)
Maximum Allowable Outlet(Casing)Pressure() Start-to-Discharge is 140 to 2000/6 over setpoint
Operating to Avoid Internal Part Damage: from 20-inches w.c.to 2.2 psig(50 to 152 mbar)
3 psid(0.21 bar d)above outlet pressure setting
E Spring Case Vent Connections
Emergency:20 psi(1.4 bar)
3/4 NPT with removable screen
Outlet Pressure Ranges
See Table 1 Temperature Capabilities(')
-20°to 160°F(-29°to 71°C)
Orifice Size Approximate Weight
1/84nch(3.2 mm)orifice2.35 pounds(1 kg)
Flow Coefficients Construction Materials
Wide-Open C.for Relief Sizing: 12.5 Body,Spring Case,Diaphragm Plate,and
Wide-Open C.for Relief Sizing:0.36 Orifice:Aluminum
Cl:35 Diaphragm,Disk,and O-ring:Nitrile(NBR)
IEC Sizing Coefficients Adjusting Screw and Pushpost:DelrirA
XT Q.78 Closing Cap:ASA Thermoplastic(UV-Ray Resistant)
Fo:0.82 Control Spring:Zinc-plated steel
FL:0.89 Machine Screw,Spring Seat.
Flow Capacities and Lever:Zinc-plated steel
p Valve Stem:Zinc
See Table 2 Relief Valve Spring,Relief Spring Retainer,
Lever Pin,and Vent Screen:Stainless steel
1.Ttie 0 n R gqwm I Gft in aft t tam at any awkiote sumeam mr="vow not no exceeded
D&n*is a=0 awned by E 1.du Pont de Ohmmm and Co
In addition.Type R622 regulators have internal relief Specifications
across the diaphragm to help minimize overpressure.
Any outlet pressure above the start-to-discharge point The SpedficaWns section lists specifications for Type R822
of the non-adjustable relief valve spring moves the Pressure Reducing Regulators. As it originally comes
diaphragm off of the relief valve seat,allowing excess from the factory,specifications for a given regulator
pressure to bleed out through the screened spring are stamped on the spring case nameplate.
case vent.
Table 1. Outlet Pressure Ranges
OUTLET PRESSURE RANGE CONTROL SPRING PART CONTROL SPRING SPRING WIRE DIAMETER. SPRING FREE LENGTH.
NUMBER COLOR CORE INCHES(MM) INCHES(t><M)
1.8 to 2.24mcbm W.C.(4 to 5 tabar) T 14453T0012 Putple 0.051(1.30) 3.40(86.4)
5 to 74=hm w t«(12 to 17 n9bar) T 14398T0012 Ordige 0.062(1.58) 3.40(86.4)
6.5 to 94mroes w.e.(16 to 22 mbar) T 14399T0012 Yenow 0.067(1.70) 3.61(91.7)
9 to 134ndws w.c.(22 to 32 n1w) T 14400T0012 silver 0.072(1.83) 4.10(104)
13 to 204nd1es W.C.(32 to 50 mbar) T 14401 T0012 Gray 0.080(2.03) 3.60(91.4)
16 to 35.mdtas w.C.(40 to 87 mbar) T 1440270012 Ptl* 0.093(2.36) 3.52(89.4)
1 to 2.2 psig(69 to 152 mbar) T1440370012 Light Blue 0 105(2.67) 3.66(93.0)