HomeMy WebLinkAboutProduct Review; Kohler Multi-Fuel LPG or Natural Gas Generatorr� KOHLER, I�:~t"A 4%46 )rn� 20RESD Models: Multi -Fuel ST.'Lude County, Permittino LPG/Natural Gas 09001 ��� �� I .°' InnvP.. Standard Features KOHLER. _ AWARD • RDC2 Controller NATIONALLY REGISTEREDoDyR�'° .50 o One digital controller manages both the generator set and ARCHITECTURAL RECORD transfer switch functions (with optional Model RXT transfer switch) o Designed for today's most sophisticated electronics o Electronic speed control responds quickly to varying household demand o Digital voltage regulation protects our sensitive electronics from hharmonic distortion and unstable power ST.LUCIE COUNTY quality PLAN REVIEW o Two-line, backlit LCD display with adjustable contrast is easy to read even in direct sunlight or low light BLDG: • Kohler Command PRO Engine Features r, DATE: o Kohler Command PROD OHV engine with hydraulic valve L lifters for reliable performance without routine valve adjustment or lengthy break-in requirements DATF, 2-Z7 9.m Powerful, reliable air-cooled performance PLUMB: o Simple field conversion between natural gas and LPG fuels while maintaining emission certification The Kohler® Advantage DATE: 9 Aluminum Sound Enclosure and Skid MECH: • High Quality Power o Wind rated up m to 181 h p Kohler home generators provide advanced vo ft'&%Rd o Weather -resistant cashmere textured finish 0 frequency regulation along with ultra -low levels of • Designed for Easy Installation 0 5 harmonic distortion for excellent generator power quality to o Hinged, locking roof 10 a -*,protect your valuable electronics. o Fuel and electrical connections through the enclosure wo • Extraordinary Reliability eliminate the need for stub -ups through the bottom 94, Kohler is known for extraordinary reliability and o Load connection terminal block allows easy field wiring 10 performance and backs that up with a premium 5-year or o Designed for outdoor installation only 2000 hour limited warranty. • Perfect for Tight Lot Lines Can be placed as close as 18' inches from your home or small business, providing installation flexibility even on smaller lots. * • Powerful Performance Exclusive PowerBoost— technology provides excellent starting power.* • Fast Response Kohler generators restore power to your home quickly and reliably. • Quiet Operation Kohler home generators provide quiet, neighborhood - friendly performance. Generator Ratings • Certifications o Meets emission regulations for U.S. Environmental Protection Agency (EPA) with both natural gas and LPG Note: CARB does not regulate emergency standby generators with outputs less than 50 HP. Only the EPA standards apply. o UL 2200/cUL listed (60 Hz model) o GSA certification available (60 Hz model) o Accepted by the Massachusetts Board of Registration of Plumbers and Gas Fitters • Approved for stationary standby applications in locations served by a reliable utility source. • Warranty o 5-year/2000 hour warranty for on -grid (standby) applications in locations served by a reliable utility source Standby Ratings Natural Gas LPG Model Voltage Phase Hz Alternator kW/kVA Amps kW/kVA Amps 20RESD 120/240 1 60 2F7 18/18 75.0 20/20 83.3 116/230 1 50 2F7 14/14 60.8 15/15 65.2 RATINGS: Standby ratings pplyto installations served by a reliable utilftysource. All single-phase units are rated at 1.0 powerfactor. The standby rating is applicable tovariable loadswith an average load factor of 80%for the duration of the power outage. No overload capacity is specified at this rating. Ratings are in accordance with ISO-3N46/1, BS5514, AS2789, and DIN 6271. GENERAL GUIDELINES FOR DERATING: ALTITUDE: Derate 4% per 305 m (1000 ft.) elevation above 153 m (500ft.). TEMPERATURE: Derate 2%per 5.5°C (101F) temperature increase above 16°C (601F). Availability issubjecttochangewithoutnotice. The generatorset manufacturer reserves the rightto change the design or specifications without notice andwithout any obligation or flabilitywhatsoever. Contact your local Kohler Co. generator distributor for availability. * The required distance from a structure is dependent on state and local codes. Generator must be located away from doors,.windows, and fresh air intakes. See the Installation manual for guidelines. G4-247 (20RESD) 10/15b e. -t Alternator Specifications Alternator Specifications PowerSoost' Generator Specifications 1-Phase Manufacturer Kohler Output reconnectable 120/240 Type 2-Pole, Rotating Field Leads, quantity 4 Voltage regulator Digital Insulation: NEMA MG1-1.66 Material Class H Temperature rise Class H Bearing: quantity, type 1, Sealed Ball Coupling Direct Amortisseur windings Full Voltage regulation, no-load to full -load RMS ±1.0% One-step load acceptance 100% of Rating Peak motor starting WA: (350% dip for voltages below) 240 V, 1 ph 2F7 (4 lead) 41 (60 Hz) 230 V, 1 ph 2F7 (4 lead) 28 (50 Hz) Engine Engine Specifications Manufacturer Koh Engine: model, type CH1000 Cylinder arrangement V- Displacement, cm3 (cu. in.) 999 (61) Bore and stroke, mm (in.) 90 x 78.5 (3.54 x 3.1) Compression ratio 8.8:1 Main bearings: quantity, type 2, Parent Material Rated RPM 60 Hz 3600 50 Hz 3000 Max. engine power at rated rpm; kW (HP) LPG, 60 Hz 23.0 (30.9) LPG, 50 Hz 20.0 (26.8) Natural gas, 60 Hz 20.2 (27.1) Natural gas, 50•Hz 1&8 (22.5) Cylinder head material Aluminum Valve material Steel/Stellite® Piston type and material Aluminum, Alloy Crankshaft material Heat Treated, Ductile Iron Governor: type Electronic Frequency regulation, no load to full load Isochronous Frequency regulation, steady state to.5% Air cleaner type Dry Kohl 'Exhaust Exhaust System Exhaust temperature exiting the enclosure at rated kW, dry, I (IF) 260 (500) Alternator Features • Compliance with NEMA, IEEE, and ANSI standards for temperature rise . Self -ventilated and drip -proof construction • Windings are vacuum -impregnated -with epoxy varnish for dependability and long life. • Superior voltage waveform and minimum harmonic distortion from skewed alternator construction • Digital voltage regulator with +1.0% no-load to full -load RMS regulation • Rotating -field alternator with static exciter for excellent load response • Total harmonic distortion (THD) from no load to full load with a linear load is less than 5% Application Data Engine Electrical �— Engine Electrical System Ignition system Electronic, 4-Cycle Capacitive Discharge 2 Starter motor rated voltage (DC) 12 Battery (purchased separately): Ground Negative Volts (DC) 12 Battery quantity 1 Recommended cold cranking. amps: (CCA) rating for -18°C (0°F) 500 Group size 26 Lubrication Lubricating System Type Full Pressure Oil capacity (with filter), L (qt.) 1.9 (2.0) Oil filtec quantity, type 1, Cartridge Oil cooler Integral Fuel Pipe Size Minimum Gas Pipe Size Recommendation, in. NPT Natural Gas LPG Pipe Length, 281,000 340,000 m (ft.) Btu/hr. Btu/hr. 1 8 (25) 1 3/4 15 (50) 1 1 30 (100) 1 1/4 1 46 (150) 1 1/4 1 1/4 61 (200) 1 1/4 1 1/4 G4-247 (20RESD) 10115b Fuel Requirements RDC2 Controller Fuel System 20RESO Fuel types Natural Gas or LPG Fuel supply inlet 112 NPT Fuel supply pressure, kPa (in. H20): Natural gas 0.9-2.7 (3.5-11) LP 1.7-2.7 (7-11) Fuel Composition Limits * Nat. Gas LPG Methane, % by volume (minimum) 90 min. - Ethane, % by volume (maximum) 4.0 max. - Propane, % by volume 1.0 max. 85 min. Propene, % by volume (maximum) 0.1 max. 5.0 max. C4 and higher, % by volume 0.3 max. 2.5 max. Sulfur, ppm mass (maximum) 25 max. Lower heating value, MJ/m3 (Btu/fM, (minimum) 33.2 (890) 84.2 (2260) * Contact your local distributor for suitability and rating derates based on fuel compositions outside these limits. Operation Requirements Fuel Consumption Fuel Fuel Consumption, m3/hr. (cfh) Model Type % Load 60 Hz 50 Hz 100 8.0 (281) 6.4 (225) 75 6.9 (243) 5.4 (189) Natural 50 4.6 (161) 3.9 (139) Gas 25 3.6 (127) 2.9 (103) Exercise 2.0 (71) 2.0 (71) 20RESD 100 3.9 (136) 2.9 (102) 75 3.1 (109) 2.4 (85) LPG 50 2.3 (82) 1.8 (63) 25 1.7 (59) 1.3 (47) Exercise 1.0 (35) 1.0 (35) Nominal fuel rating: Natural gas: 37 MJ/m3 (1000 Btu/ft.3) LPG: 93 MJ/m3 (2500 Btu/it.3) LPG conversion factors: 8.58 ft.3 = 1 lb. 0.535 m3 = 1 kg 36.39 ft.3 = 1 gal. Sound Data Model 20RESD 8 point logarithmic average sound levels are 64 dB(A) during weekly engine exercise and 69 dB(A) during full -speed generator diagnostics and normal operation. For comparison to competitor ratings, the lowest sound levels are 62 dB(A) and 67 dB(A) respectively.* All sound levels are measured at 7 meters with no load. * Lowest of 8 points measured around the generator. Sound levels at other points around generator may vary depending on installation parameters. v.MW: 240v A Fe¢ WA HZ The RDC2 controller provides integrated control for the generator set, Kohler® Model RXT transfer switch, programmable interface module (PIM), and load shed kit. The RDC2 controller's 2-line LCD screen displays status messages and system settings that are clear and easy to read, even in direct sunlight or low light. RDC2 Controller Features • Membrane keypad o OFF, AUTO, and RUN push buttons o Select and arrow buttons for access to system configuration and adjustment menus • LED indicators for OFF, AUTO, and RUN modes • LED indicators for utility power and generator set source availability and ATS position (Model RXT transfer switch required) • LCD display o Two lines x 16 characters per line o Backlit display with adjustable contrast for excellent Visibility in all lighting conditions • Scrolling system status display o Generator set status o Voltage and frequency o Engine temperature o Oil pressure o Battery voltage o Engine runtime hours • Date and time displays • Smart engine cooldown senses engine temperature • Digital isochronous governor to maintain steady-state speed at all loads • Digital voltage regulation: -- -1.0% RMS no-load to full -load • Automatic start with programmed cranking cycle • Programmable exerciser can be set to start automatically on any future day and time, and run every week or every two weeks • Exercise modes o Unloaded weekly exercise with complete system diagnostics o Unloaded full -speed exercise o Loaded full -speed exercise (Model RXT ATS required) • Front -access mini USB connector for SiteTech- or USB Utility connection • Integral Ethernet connector for Kohler® OnCue(D Plus • Built-in 2.5 amp battery charger • Remote two -wire start/stop capability for optional connection of a Model RDT transfer switch See additional controller features on the next page. G4-247 (20RESD) 10/15b i K�HLER® KOHLER 001, Kohler, Wisconsin 920-4 9-164 USA Phone 920-457-4441, Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada, phone 1-800-544-2444 . KOHLERPower.com Additional RDC2 Controller Features • Diagnostic messages o Displays diagnostic messages for the engine, generator, Model RXT transfer switch, programmable interface module (PIM), and load shed kit o Over 70 diagnostic messages can be displayed • Maintenance reminders • System settings o System voltage, frequency, and phase o Voltage adjustment o Measurement system, English or metric • ATS status (Model RXT ATS required) o Source availability o ATS position (normal/utility or emergency/generator) o Source voltage and frequency • ATS control (Model RXT ATS required) o Source voltage and frequency settings o Engine start time delay o Transfer time delays o Voltage calibration o Fixed pickup and dropout settings • Programmable Interface Module (PIM) status displays o Input status (active/inactive) o Output status (active/inactive) Load control menus o Load status o Test function Generator Set Standard Features • Battery cables • EPA certified fuel system • Aluminum sound enclosure • Critical silencer • Field -connection terminal block • Fuel solenoid ,valve and secondary regulator • Line circuit breaker, 100 amps • Multi -fuel system, LPG/natural gas, field -convertible • Oil drain extension with shutoff valve • Premium 5-year/2000 hour limited warranty • RDC2 generator set/ATS controller • Rodent -resistant construction • Sound -deadening, flame-retardant foam per UL 94, class HF-1 Available Options Approvals and Listings ❑ CSA Approval Communication Accessories ❑ OnCue® Plus Generator Management System ❑ OnCue• Plus Wireless Generator Management System Electrical System ❑ Battery ❑ Battery heater ❑ Emergency stop kit Available Options, Continued Controller Accessories ❑ Programmable interface Module (PIM) (provides 2 digital inputs and 6 relay outputs) ❑ PowerSync•+Automatic Paralleling Module (APM) , (single phase only) Fuel System LJ Flexible fuel -line Literature ❑- General maintenance literature kit ❑ Overhaul literature kit ❑ Production literature kit Starting Aids ❑ Carburetor heater (recommended for reliable starting at temperatures below, O'C [32�F1) 0 Fuel regulator heater pad (recommended for reliable starting at temperatures below -180C [0°F]) Automatic Transfer Switches and Accessories ❑ Model RDT ATS ❑ Model RXT ATS' ❑ Model RXT ATS with combined interface/load management board ❑ Load shed kit for RXT or RDT ❑ Power relay modules (use up to 4 relay modules for each load management device) ❑ Other KohlerO ATS Generator Set Dimensions and Weights Overall Size, L x W x H: 1215 x 733 x 802 mm (47.9 x 28.8 x 31.6 in.) Shipping Weight (with aluminum enclosure) 240 kg (530 lb.) H 0 0 j� LW NOTE Dimensions are provided for reference only and should not be used for planning installation. Contact your local distributor for more detailed information. DISTRIBUTED BY: All rights reserved CA-247 CWF EW) 10119t