Loading...
HomeMy WebLinkAboutEnergy CodeFORM 60OA-97 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING. CONSTRUCTION Florida Department, of Community -Affairs Residential Whole Building Performance- Method A Project Name: MOD-062 Builder: JACOBSEN HOMES Address: 9801 S. OCEAN DRIVE, LOT 101-1 Permitting Office: ST. LUCIE COUNTY City, State: JENSEN BEACH, 'FL 34957- Permit Number: Owner: SAM & ROSE ADAMS Jurisdiction Number: 661000 Climate Zone: Central 1. New construction or existing New _ 12. Cooling systems 2. Single family or multi -family Single family ✓ a. PTAC and Room Unit Cap: 24.0 kBtu/hr 3. Number of units, if multi -family 1 _ EER: 10.00 4. Number of Bedrooms 2 _ b. N/A _ 5. Is this a worst case? No 6. Conditioned floor area (W) 880 fiz ✓ c. N/A _ 7. Glass area & type a. Clear - single pane 11.4 fi' 13. Heating systems b. Clear - double pane 0:0 ftZ _ _ a. Electric Heat Pump Cap: 10.0 kBtuthr '� c. Tint/other SC/SHGC -single pane 139.6 fig _ HSPF: 6.60 +� d. Tint/other SC/SHGC - double pane 0.0 fis b. N/A _ 8. Floor types a. Raised Wood, Post or Pier R=22.0, 880.02 _� c. N/A _ b. N/A c. N/A 14. Hot water systems 9. Wall types _ a. Electric Resistance Cap: 30.0 gallons a. Frame, Wood, Exterior R=19.0, 894.1 flz _ EF: 0.89 t/ b. N/A _ b. N/A _ c. N/A _ d. N/A _ c. Conservation credits _ e. N/A (HR Heat recovery, Solar 10. Ceiling types _ DHP-Dedicated heat pump) a. Under Attic R=26.0, 886.0 ft- _✓ 15. HVAC credits PT-C, PT-H Poo b. N/A _ (CF-Ceiling fan, CV -Cross ventilation, c. N/A HF-Whole house fan, 11. Ducts _ PT -Programmable Thermostat, APPROVED BY a. Sup: Unc. Ret Unc. AH: Outdoors Sup. R=6.0, 116A ft _ RB-Attic radiant barrier, b. N/A W-C-Multizone cooling, M&H-Multizone heating) In Glass/Floor Area: 0.17 Total as -built points: 14444.00 PASS Total base points: 14877.00 I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: .ram DATE: - Review of the plans and z"E sr specifications covered by this 1,04 aT�o calculation indicates compliance with the Florida Energy Code. Before construction is completed - this building will be inspected for rr compliance with Section 553.908 y� Florida Statutes. ° BUILDING OFFICIAL: DATE: OCT to 1n. .5Ni - - EnergyGauge® (Version: FLRCNA-200) 1 . % i -1 600 Packard Court Safety Harbor, Florida SUPPLY -AND PLUMBING WASTE LINES AXLES: 3 IDLERS & 1 BRAKE I -BEAM SIZE: 10 INCH 36" SWINGING DOOR 32" SWINGING DOOR = 30" SWINGING DOOR EXTT, STUDS: 2 X 6 SPF JJ @ .16" O.C. TOP PLATE: 2 X 6 SPF P SIDING. VINYL LAP SIDIPIG BOTTOM TRIM: NONE TOP TRIM: NONE. INSTALLATION: BY OTHERS NUMBER OF BATHS 2 NUMBER HANDICAP: 0 NUMBER VANITY 2 0v s 34695 Phone (813) 726-1138 GENERAL NOTES, ITEMS INSTALLED BY OTHERS (SUBJECT TO LOCAL CODES) - FOUNDATION BLOCKING AND TIE --DOWNS FRONT & REAR STEPS AND/OR LANDINGS, ELECTRICAL. HOOK UP TO PANEL BOX FRAME AND FLOOR HITCH: REMOVABLE DECKING: 79/32" PLYWOOD OR O:SB. fNSULATION. R- 22 FLOOR JOISTS: 2 X 8 SPF ,f3 @ 16" O.0 FLOOR COVERING: VINYL -BATHS & KITCHEN - DOOR SCHEDULE = 28" SWINGING DOOR S36 = 36' SUDING DOOR 9 = DBL 3V SWING DOORS D18 = DBL 28" SWING DOORS sA = 24" BI-FOLD DOOR = 24" SWINGING DOOR S28 = 28' SLIDING DOOR (a = DEL 3Y SWING DOORS D24 = DBL 24" SWING DOORS sE = 30" BI-FOLD DOOR = 18" SWNGNG DOOR s24 = 24" SIDING DOOR (go = DBL 30" SWING DOORS ot8 = DBL 18' SWING DOORS sc = 36" BI-FOLD DOOR WALLS —WINDOWS -DOORS BOTTOM PLATE: 2 X 6 SPF - 3 INSULA T ION: R-19 INT. DOORS: HOLLOW CORE SHEA7HING: 3/8" PLYWOOD OR OSB EXT. DOORS.- STEEL/GLASS WINDOWS: SINGLE PANE ANTED EXTERIOR COVERING AND ROOF DECALS: NONE TRUSS: 16" O.C. MONO TRUSSES INSULATION: R- 26 SPECIAL METAL TRIM WINDOWS & DOORS ROOF DECKING: 7/16" O.S.B. AE DOWNS. 64" O.C. ROOFING: ASPHALT SHINGLES CEILING: 1/2" TEXTURED GYP. - A/C & HEAT TYPE A/C: PACKAGED TYPE HEAT ---LEE ENERGY CALC R.A. SYSTEM: DUCTED RESTROUS HANDICAP LAV.: 0 MEDICINE CABINETS: 2 HANDRAILS: 0 STANDARD COMMODE: 1 MED. CAB. W/LIGHT 0 WATER HEATER: 30 GA. W/PAN HANDICAP COMMODE: 1 MIRRORS: 2 48" SHOWERS: 1 MISCELLANEOUS ACCESS BELOW REMOVABLE SWIVEL P-TRAPS / OPTIONAL FACTORY BUILT FIREPLACES INSTALLED IN ACCORDANCE WITH SMC 306.17 CODES. SBC, NEC / SEALS: FLORIDA to / ,6y S 9 7a = 48" IO-FOLD DOORS �e = 60" M-FOLD DOORS �c = 72" BI-FOLD DOORS �� Z Z tri O Q m J O r Q J � J U z CL Qz U o� T1Z �w QD 'tea z zz L' w� z Q m o� c, Q LO to zz 8 z U O O 4 * ALL GLASS IN DOORS SAFETY GLAZED ¢ cp N ' O rl _ . o� a Z m Ef? 4 0 Q_ - W � co Fyl U - _ o N _ W O O 1� z a� �eM �o o=OO 54" TUB. OTHER; 1 CORNER SHOWER C2 a a o fM r) Q —APPROVED BY z q> q> o i inn Za o LL, 10 V • 1-1� 4 -CC 11* u ZO.J-3 S -AL-i I U r O Z Q coo �' O ELECTRICAL' NOTES AND SPECIFICATIONS o L q � z W � OPTIONAL FRESH FLUORESCENT LIGHT INCANDESCENT LIGHT FAN/LIGHT COMBO. AIR FAN RECEPTACLES NIP Q W o: z oo R r-----� _ MH 62O2 O. QL�, j � a — J 67 H.V. TYPICAL TYPICAL TYPICAL %� Q p W Q RECESS OR SURFACE MOUNT STANDARD POSITIONED RECESSED 2 SRITCHES (140 CFM) WHOLE HOUSE VENT FAN 120 VOLT 240 VOLT 120 VOLT U p Q JUNCTION BOXES SMOKE DETECTOR THERMOSTAT ELECTRICAL PANEL SWITCHES W Z 5 0: z w t�1 W 4 0 AT EDGE UNDER MIDDLE TELEPHONE PREP. TELEVISION PREP. OF FLOOR OF FLOOR ELECTRICAL SCHEDULE 0. cn BREAKER WIRE BREAKER WIRE J O Z W 4 o0 BREAKER. WIRE U CIRCUIT NOMENCLATURE CIRCUIT NOMENCLATURE CIRCUIT NOMENCLATURE (AMPS) (CU.) (AMPS) (CU.) (AMPS) (CU.) z z 1 - 6(A)* SMALL APPLIANCE 20 12-2 16 ELECTRIC RANGE 40 8-3 21 ELECT. COOK TOP 30 10-3 �-z W o n. r� U U 7 - 12 GENERAL LIGHTING 15 14-2 17 DISHWASHER 15 14-2 22 WALL OVEN 20 12-3 a Z Uo � p Q 13 GROUND FAULT 15 14-2 18 DISPOSAL 15 14-2 23 HVAC 50 6-3 tip p U Z ¢ U Q Q s Za 14 GROUND FAULT 20 12-2 19 LAUNDRY 20 12-2 24 - - - 15 - 15/2 WATER HEATER 20 1 12-2 20 DRYER 30 10-3 25 - - (a) = GROUND FAULT PROlECTFO ELECTRICAL PANEL SIZING a, a o DESCRIPTION KVA TOTAL KVA FROM LEFT = 28.64 ENTRANCE PANEL: 150 AMP MAIN BREAKER SINGLE PHASE GENERAL LIGHTING 880 SF AT .003 KVA = 2.64 N ¢ 3 20 AMP SM. APPLIANCE AT 1500 VA/1000 = 4.50 FIRST 10 KVA AT 100% = 10 ENTRANCE CONDUIT. 1 - 2 INCH p z O RANGE/COOK-TOP CAD 40 AMPS X 120/1DOD = 9.60 REMAINDER AT 40% = 18.64 X .4 = 7.46 _ z `' ADD177ONAL CONDUIT DROPS: I 1 INCH z W WALL OVEN @ 20 AMPS X 240/1000 = 0.00 TOTAL OTHER LOAD = 17.46 WATER HEATER 19.2 AMPS X 240/1000 = 4.60 A/C AT 100% = 50 AMPS X 240/1000 = 12.00 COMBINATION FAN/LIGHTS ON SEPERATE SWITCHES o o o DISHWASHER 0 11.5 AMPS X 120/1000 = 0.00 TOTAL KVA = OTHER LOAD + AIR CONDITIONER = 29.46 DRYER ® 24.17 AMPS X 240/1000 = 5.80 LAUNDRY - 20 AMPS AT 1500 VA/1000 = 1.50 TOTAL KVA X 1000 = 29,460 VOLT AMPS _ Mco OTHER DISPOSAL AT 9 AMPS X 120/1000 = 0.00. VOLT AMPS / 240 VOLTS = 122.75 AMPS U :2- TOTAL KVA FROM ABOVE = 28.64 USE 150 AMP MAIN BREAKER MIN. - o 5 ELECTRICAL .NOTES o CC -O N INCANDESCENT. AND FLUORESCENT LIGHTS LOCA TED IN CLOSETS MUST BE AT LEAST 18 INCHES AND 6 INCHES, RESPEC77VELY FROM COMBUSTIBLE MATERIALS IN AN AREA EXTENDING FROM THE CEILING TO THE FLOOR oo = �o"o_, ON ALL SIDES OF THE LIGHT. o ¢= r N QQ o0 o CCzto ALL CIRCU17S. CROSSING OVER MODULE MATING LINE(S) SHALL BE SITE CONNECTED 1N APPROVED ACCESSIBLE JUNCTION BOXES Lr, o zd OCTa La o� THE MAIN ELECTRICAL PANEL AND FEEDERS ARE S17E INSTALLED BY OTHERS AND ARE SUBJECT TO LOCAL CODE JURISDICTION. y Z c z (M62002) o LL- �d Q Q � O O U J d ma Q o --�LLJ o ti o oLL- x o U Lu IaJ W Q � ~ Z CZ LLJ J 8'-41 4' 4 /4' 2'-0' 41 4• 11'-10 41 it'-0' 18-91 4' 5 7 8" � Q O Z 3 O W Q a Q T-2 3/8' 21'-4 5/8' if cl ' jj---"�---- Q O OW25-4 3/432=8 71ir 3-0 3/4' � 2-5 7/39 1/2FROM F R zX5131x401/4- xS11 - -- --301 �p x Q ry o w LL� + 1 I I PHONE A4S cn a I I N BEDROOM 2 PHONE PREP. _r__ ---- 12Ox25 v 5- z o c>a 44. 1 109 I - (RA«x DI93NG I I� � a Q m 0 o i 48 x 3+ I I r -� Q >J OU � p O t.MRMH S 7 1 S14 FAN PREP. 1 t5 x S M Z Q O. I I 73' I o I I I M l � / 3ao1 62• � I o v~i o o_ Z �_ a j HMCI CAP I ! \ (�--------- S3 ~ �' Lu FU- 014P a'fJ i � ? I( = L -{I L J 2Sio' { Will ONE '6 N 41 O Z Z CO U Q Z I SIK I A2 I I REFER 1 I` tJ) cn rn t, �C Q tr1 8X24 I OF .- W/bEAD 1 SOLID I I � Q O O U J Z a 10 N PREP. PANTRY // � U o ¢ ZE 32' X 7 1/4' \ 1 STORM D �� TV W. ADD1�'PAH O /W1 s **R-22 FLOOR INSULATION** VpIm�\ / a,l 1 �MRRM ( \CONDO � s \ **R-26 ROOF INSULATION**WP s O ( 591/3 O T 33 3/4 — o 0 ICM \ o sr FAH PREP, f 19 to O �• aEAa ae FAN PREP. N cfl M MI II BEDROOM M1 / �^ NP'� LIVINGROOM I=4� w m 11RROi8•D- 135 li l MH **MULLLIONS ON ALL WINDOWS** I * � o Q 4 w L — — 301/2• X 54 � — — — — — 301/Y x 54 I B I— — 14 I/2 % ° 1/4' - — 30 I/2' x 541/8 - 54 — — — — 301/2• % 1 b — O .. t�j 1/2 OCT. NOW ABOVE • � 1/2 OCT. WNDOW ABOVE � OBS. 1/2 OCT. WHDOW ABOVE Y$ 11/2 OCT. WINDOW ABDWE x � 7-5 7/8' 1+'-a 3/4 1-71/8' 22'-a 3/4 2r-11 3/6' JACOBSEN HOMES 40'-0 31C —•il * o 24'--r 25-4 3) MCP-1153-062* HITCH o N ++'-o' MOD-062 �N CHANCELLOR a L 122-0' 15-9 9'-0' 41/4 ©fin 15-21 5 7 O= Q o 41 4 41/4 v a� 33�51/4 Q ,a? Q (3 b O START r WALL AT 3r-51/2' 44'-C I-11 5/8' C-7 1/8' 1E'-9 I/fl' 36-0 3/8' o Q - I BULB BOTH WALLS 103 3/4 HIM 9'-115 �. 1T-71/g 17-1 24� {34 3/4} 0-61/e') �' 3 4 38• % 80 3/4 (16 3/4} c� Q Z � tn 32' % (91 3/a} 21'-1 5/9• 44-0' -" I i .� L V 14'-8 3/4' -"} (53 SA) I U C BUILD THIS WAIL AS A 6• WALL START 4 WILL AT 17-0 3/4• - H 21-15/e '- � C \/6, y APPROVED BY o (a FLOOR PLAN_ a o z u lmn 9nn.3) 13x . ,say-o• 4p wP 13 444 JACOBSEN HOMES HITCH MCP-1153-062* MO _062 © 3=17-98 CHJ MCR / ,APPROVED BY ELECTRICAL LAY -OUT INs o N d U � °- U Z -9 O O W J Q J OLz) X O � - z ca L Q Q W � w J w U w¢ � C7 � Qo � z a o co o O � � zz .a z W a CJ V L, � � N Q Q � 1 o M z z m W z w b o `o W co x � n U O TTl�� co a ¢ o cn q�0tn _N o �ZW z b � M o z � o z � (M6?004) FRONT ELEVATION LEFT ELEVATION TYMCAL FTAINOAM H FOUNDATION SITE MSTALLEB BY OTHERS, SL®JECt TO LOCAL CODES ANo unmenm FRONT AND LEFT ELE ATION ELEVATION NOTES: SEE CROSS-•SECDCN ft 8 of 9) FOR ROOF 4E UEON AND (Pgs 8 & 9 of 9) FOR CRAWL SPACE MORYATiOIL (FUDAVON SITE INSM IED, BY OTHERS SUBJECT TO LOCAL JJft mnmL) r^ to Z� �r APPROVED BY am f r. Zm S INC. o �¢ C] a O � � � U tri p J Q �UQ- k ti C-] W W Op Q O U- z m �LU z o ac ¢ zz a U o¢ ti p S m C� w¢ W ``' V 6i W Ul 11 J o U LI: O F- O Z ti W � V tip j Q W� ¢ ~ L V3 O a U o •� U O ¢s Q ml• ' o 0 rn 11 1 Q N U-3 O r7 z a p O N CL W w � " o n °o a V � � (0 a Fes - a a� a0 N pF-.Q� ca (5 Qzwcvo) a o ° C "� c o q) z o . O z (M62005) REAR ELEVATION RIGHT ELEVATION TYPCCAL FBUNBATION FOUNDATION SITE NSTXLED BY OTIf n SUBJECT TO LOCAL CADES AM JUfdMCiDL REAR AND RIGHT ELEVATION C X Ir TYPICAL VENT FOUNDAION VEN11 TON ELEVATION NOTES: SEE CROSS-SECTION (Pg. 8 of 9) FOR ROOF VNIUUION AND (Pg& 8 It 9 of 9) FOR CRAWL SPACE BFOtgAAI M (FOMATION STE INSTALLED BY OTIM SUBJECT M LOCAL JURISCNnmL) xi�- 0 "I 4r ?PROVED BY " CT INS � N ti ¢ U CL O ¢ � cm 2 C-3 O U z o ma -.J Zi 0 3 Q �L k O Uw w W ¢U O a� z m w C Z�2 Q m Q ¢W LU Q 4 CL V p ¢ Lj.j L'i O ,� Z Q W. 4 Z 6 w co J � o > co �u I. Lu" aQc wrn c, ~o o z � N C, O O CL 'II Cfll m T z n 4 to o �M 00 0 Ub M I -C3 � h C"a co accA ¢ coo � oCM LC) Z O C d O o v o z w DISTANCE OF FIXTURE TRAP FROM VENT �+ SHUT-OFF SIZE RE DISTANCE FROM TEMPERATURE AND DRAIN VALVE SIZE OF TRAP FALL PER FOOT rn PRESSURE RELIEF VALVE 1 1/2" 1 1/4' 1/4' S-0� H 1 I/2" 1 1/2' 1/4' NOTE WATER HEATER 1' MINIMUM A E SHUT-OFF 2' 1 1/2" 1/4• 6-0' OUTLETS SHOWN ON OVERFLOW A VALVE TOP MAY BE LOCATED THRU FLOOR T T Y 2" 1/4' 6'-0' ON SIDE OF TANK E E HOT R P. 3' 3' 1/8' 1O'-0' TEMPERATURE AND PRESSURE COLD RELIEF VALVE DRAIN MAY 4" 12'-O" BE DISCHARGED INTO THE WATER HEATER SAFETY PAN WATER HEATER (PER SPC 1213.7) PAN WITH DRAIN ``-- WATER INLET WATER HEATER PAN SHALL BE 24 GA. GALV. STEEL (OR EQUAL) 1 1/2" DEEP MINIMUM, AND OF SUFFICIENT SIZE AND SHAPE TO WHEN THE DISCHARGE FROM THE RELIEF VALVE(S) IS T\BE RECEIVE ALL DRIPPINGS OR CONDENSATE FROM THE WATER HEATER DISCHARGED INTO THE WATER HEATER PAN IT SHALL BE AND THE DISCHARGE FROM THE RELIEF VALVE OR VALVES. PIPED FULL-SIZE OF THE VALVE OUTLET PIPE TO. A POINT THE PAN SHALL BE DRAINED BY AN INDIRECT WASTE PIPE NO LESS NOT MORE THAN TWO (2) INCHES OR NO LESS THAN ONE THAN ONE (1) INCH IN DIAMETER OR THE DIAMETER OF THE OUTLET (1) INCH ABOVE THE PAN FLOOD LEVEL RIM. OF THE REQUIRED RELIEF VALVE(S) WHICHEVER IS LARGER. WATER HEATER DETAIL 1 1/2' VENT THRU ROOF J1 1/2" VENT THRU ROOF 1 1/2"VENT THRU ROOF OR AUTO VENT V 3" VENT THRU ROOF I _ 1 1/2" VENT THRU ROOF J (SEE PLAN FOR LOCATION) I v OR AUTO VENT J ( OR AUTO VENT TUB J J 1 1/2' VENT THRU ROOF 1 1/2' VENT THRU ROOF L TUB OR AUTO VENT OR AUTO VENT OR JOIN W/ 3" VENT LAV, WASHER 1 1/2' W.C. 2' W.C. WET VENT KIT. SINK 1/2' SHOWER W.C. 2" 3" :� BATH �2 " BAD 3' 2 1 1/2" TYP. 3 PLACES L- OOM (BOTH BATHS) D WV RISERS 2' -NTS- KI TCHEN ALL WATER SUPPLY LINES TO BE 3/4- ALL WATER SUPPLY STUB UPS TO BE 1/2° • _ NOTE: CONNECT ALL DROPS TO SOUTHERN PLUMBING CODES AND INSPECTED ON SITE APPROVED BY PLUMBING Dl V RISER LAY -OUT o �Q ci CL. 2 U DO J � co O Q J Q O W ti X. O O ti O Lo Qx c� W `` o a- Wti z M W z W W O ¢ �Q � � 2 U o� cl S `a W 'co J O < z w � 4 OU o _ 02 Lo W O } W Z ¢ U O ¢ 3 - N � 1 � O M aq z k ¢ O O U Q 0. rn Q � � 73 ro o c b W W 4 U? a� M vy a� o o= ¢ a l coo cn N 4 ¢ 0 o z-to zra � o o w z v o 65 1AA62007) ■ awe. xrna.� 7/16" OSB ROOF SHEATHING TO BE FASTENED TO TRUSSES WITH 8d NAILS AT 6" O.C. AT EDGES AND 12" Q.C. IN FIELD. (OR PEP. CONSTRUCTION PACKAGE) ROOF SHEATHING DETAIL DESIGN LOADS FOR 16" O.C. LISTED TRUSSES: 20 PSF LIVE LOAD TOP CHORD 6 PSF DEAD LOAD .TOP CHORD 4 PSF DEAD LOAD BOTTOM CHORD SHINGLE ROOF WITH FIBERGLASS SHINGLES LISTED RAFTERS W/UNDERLAYMENT ON 16' 0.� TYPICAL INSULATED PLYWOOD OR WAFER A/C SUPPLY SYSTEM BOARD DECKING APPROVED SLOIAN INSULATION _ 1 1/2" X 26 GA GALV. STEEL UPLIFT STRAPPING 16' O.C. MAX FASIENED FROM WALL TO -ROOF AND FRIAR WALL TO FLOOR PER CONSTRUCTICN MANUAL 2 X 5 SPF #3 MIN. TOP PLATE INTERIOR FINISH - 2 X 6 SPF #3 MIN. WALL STUDS 16' O.C. BATT INSULATION—, EXTERIOR SHEATHING EXTERIOR FINISH - (MM LAP SIDING) 12 ROOF SLOPE VARIES X4SIFF131 WALL STUDS 16" O.C. 1/2' AIR SPACE MINIMUM BLOWN INSULATION 1 X INSULATION STOP. MIN. VENTED SOFFIT INSULATION AIR SPACE . DETAIL 2 X 4 SPF #3 MIN. PERIMETER RAIL �---- RIDGE BEAM (WHERE REQUIRED) `-2 X 4 SPF #3 MIN. PERIMETER RAIL — 2 X 4 SPF #3 MIN. MARRIAGE WALL TOP PLATE 5/16" MM.-GYPSUM BOARD, mASS V -TYPICAL MULTI - WIDE CENTER LINE ROOF VENTILLATTON PER SBCC1 SECTION AREA OF UNIT (54 FL) TOTAL S0 FT. OF 2309.7 (TYP. EACH UNIT) TOO W/ VAPOR BARRIER VENTILATION REWM 2-LAYERS 15A' FELT OR 45# BARRICADE SHINGLE UNDERLAYMENT MINIMUM 1/2' MINIMUM -J SINGLE 2 X 6 - _ GYPSUM CEILING TOP PLATE W/LISTED BOARD WITH TRUSSES DIRECTLY TEXTURED FINISH OVER WALL STUDS (1 1/2' MAX OFF -SET) TYP. HEADER PER - APPROVED STRUCT. PACKAGE SEE FLOOR PLAN - FOR WIN. SPECS 2X6SPF #3MIN - SIL PLATE ]-AMU CENTER SPACING VARIES (PER MODULE WIDTH) i X OR PLYWOOD LET -IN AT DECKING SEAM (TYP) � ,.. I-BEA BLANKET INSULATION BOTTOM BOARD CROSS -MEMBER 2 X 8 SPF �3 MIN. P.T. S41 PLATE PERIMETER FLOOR JOIST SEE STRUCTURAL PACKAGE �' STRAPS :::A FOR CHASSIS SPECIFICATIONS AT COLUMNS TYPICAL hBEAM TIER NOTES: PERIMETER FOUNDATION PER LOCAL CODES SEE SET-UP M7__(� 1. ' ALL STEEL MUST COMPLY WITH ASTM A-36 (36 KSI MIN.). TYPICAL CROSS— SECTION 2. ALL LAG SCREWS MOST COMPLY WITH ASTM A-307. SHOWN AS TYPICAL DOUBLE WIDE 20'-0" INCLUDED 3. SEE SET-UP MAN. & ADDENDUM FOR PIER AND TIE -DOWN STRAPPING Ip Z6 Q i (LOCATIONS, ORIENTATIONS, AND SPECIFICATIONS). 2 X 6 SPF 0 MIN OSB FLOOR 2 X 4 SPF $3 MIN BOTTOM PLATE DECKING MARRIAGE WALL 2 X 8 MINIMUM_L__JBOTTOM PLATE FLOOR JOIST ♦ . . v . FRESH WATER SUPPLY SPF J3. 16"'O.0 ♦ ♦ ♦ ♦ . ♦ ♦ ♦ ♦ ♦ ♦ ♦ i. i i i i CZw OUTRIGGER M . - SEE DETAIL ABOW SIDEWALL AND ENDWALL EXTERIOR WALL STRUCTURAL CORNER BRACING INSTALLATION: STRUCTURAL SHEATHING SHALL CONSIST OF 48' MINIMUM WIDTH SHEET FASTENED CONTINUOUS FROM WALL TOP PLATE'TO WALL BOTTOM PLATE (SHEATHING TO EXTEND 3/4" MINIMUM ONTO TOP AND BOTTOM PLATES) ALL JOINTS SHALL BE LOCATED AT FULL DEPTH 2 X FRAMING MEMBER MINIMUM. BRACING INSTALLED AT EACH EXTERIOR CORNER BRACING MATERIAL, 1/8" STRUCTURAL RED THERMO-PLY FASTENED WITH 1 1/4" GALVANIZED ROCHNG NAILS OR 7/16' MIN. CROWN 16 GA. STAPLES 3" O.C. MAX. AT ALL PANEL EDGES AND 6. O.C. MAX. AT INTERMEDIATE SUPPORTS OPTIONAL BRACING MATERIAL 3/8" APA RATED SHEATHING EXPOSURE - 1 OR 3/8' APA RATED EXTERIOR SIDING FASTENED WITH 10d COMMON OR BOX NAILS 6' O.C. MAX. AT PANEL EDGES AND 12" O.C. MAX. IN FIELD. OR PER CONST. PKG. ACCESS FOR SHOM AND/011 TUB MU ac'T REMOVABLE P-TRAP THRU BOTTOM BOARD APPROVED BY ti Q U CL � t1 Z U = m�E 0 3 o _, � 4 ao � o c O � Q CL Q ¢w z o � U o- Lai Ln W s U 6i W � ati U W o o s Da F-- zz cz: F=- W j Q Li -~ On O V' Q Z U O d 3 4 n n rn (M62048) e � i Fm 2 � LVFIIT a �Z 12 ij, 1% ro Q .o r6'-olt -OFFSET' 1 12 614 I 11-6' 1 R �� �►-o �-�22W� c-43 © V II II jj 10X6 10X6 10X6 IQX6 10 W iQ X 6 10 BED LIVING ROOM II II 1356 152 � II I I 23'-4 N r: or- m -, 4» DUCT: 0 6" DUCT: 1397 OVERHEAD DUCT LAYOUT JACOBSEN HOMES HITCH 8" DUCT: 0 THIS DRAWING IS NOT PLOTTED TO SCALE MCP 1153 062 MOD-062 ** -22 FLOOR INSULATION** ©a-17-es lil1B **R-26 ROOF I SULA ION** ALL DUCTS TO HAVE R-6 MIN. RATING HVAC PLAIN vLW VBT. 44'-4 ^, ROVE-D BY / � Y w qq_" N � d Qw Q o z� o� Q � J Q J Q k w U w m m w Q Q) Q CL Z O �. Qo a Q CJ o W ¢ s � w � Q w a o ti O Z Cl) o w I-- a o m w U w z �. O N � rn II o I N I r I m cn U 4 �000 _o N W o o ? o -cC d- a� zli,o w�-D o _ z: "00 z� `o a a- o v "� c 4 ^^) Y Q g z rAI,Ar O 9)