Loading...
HomeMy WebLinkAboutProduct Approval; Fixed WindowsFlorida Building Code Online Page 1 of 2 BCIS Home Log In 1 User Registration i Hot Topics Submit Surcharge i Stats & Facts j Publications i Contact Us BCIS Site Map Links Search R l i Goa P � Product Approval - USER: Public User ;z �s i Product Aoproval Meru > Product or Application Search > Application List > Application Detail FL # FL17387-R2 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Custom Window Systems Inc. Address/Phone/Email 1900 SW 44th Avenue Ocala, FL 34474 (352) 368-6922 Ext291 jlathrop@cws.cc Authorized Signature Kevin Pine kpine@cws.cc Technical Representative Jay Lathrop Address/Phone/Email .1900 SW 44th Ave Ocala, FL 34474 (352) 368-6922 Ext 291 jlathrop@cws.cc Quality Assurance Representative Arturo Monteverde Address/Phone/Email 1900 SW 44th Ave Ocala, FL 34474 (352)368-6922 Ext221 amonteverde@cws.cc Category Windows Subcategory Fixed Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code File copy REVIEWED F0I4 CODE COMPLIANCE ST. LUCIE COUNTY ROCC Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer D Evaluation Report - Hardcopy Received Lucas A. Turner PE-58201 Keystone Certifications, Inc. 07/21/2030 Steven M. Urich, PE "mil Validation Checklist - Hardcopy Received FL17387 R2 COI EvalReoort10328.odf Standard AAMA/WDMA/CSA 101/I.S.2/A440-08 ASTM E1886-05 ASTM E1996-05/09 Year 2008 2005 2009 https://www.floridabuilding. org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsRyNwiNWDr... 11 /6/2020 Florida Building Code Online Page 2 of 2 Product Approval Method Method 1 Option D Date Submitted 09/28/2017 Date Validated 09/29/2017 Date Pending FBC Approval 10/04/2017 Date Approved 12/12/2017 Date Revised 08/10/2020 Summary of Products FL # Model, Number or Name Description 17387.11 PW-8150 Vinyl Fin/Flange Picture PW-8150 Vinyl Fin/Flange Picture Window, Impact, WZ3 Window Limits of Use Installation Instructions Approved for use in HVHZ: No FL17387 R2 II CWS-1032B.Ddf Approved for use outside HVHZ: Yes Verified By: Lucas A. Turner PE-58201 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: +60/-60 Evaluation Reports Other: PW-8150, Max, size 36" x 72", DP +/-60 PSF. Glass FL17387 R2 AE EvalReport1032B.odf conforms to ASTM E1300-04. Created by Independent Third Party: Yes 17387.2 PW-8300 Vinyl Fin/Flange Picture PW-8300 Vinyl Fin/Flange Picture Window, Impact, WZ3 Window Limits of Use Installation Instructions Approved for use in HVHZ: No FL17387 R2 ii CWS-1033B.Ddf Approved for use outside HVHZ: Yes Verified By: Lucas A. Turner PE-58201 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: PW 8300, See Installation Detail for Max. Sizes and FL2_7387 R2,,,AE EvaIR2D,grt103;jB pdf DP. Glass conforms to ASTM E1300-04. Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275 (1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: ME® 6L'is Credit Card Safe https://www.floridabuilding. org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsRyNwiNWDr... 11 /6/2020 . t ,1I UILt)/LULU w rlonaa tswlaing uoae unune 1 Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Date Revised Summary of Products Method 1 Option D 09/28/2017 09/29/2017 10/04/2017 12/12/2017 08/10/2020 RECEIVED C 2020 Permitting Department St. Lucie Cotanty FL # Model, Number or Name Description 17387.1 PW-8150 Vinyl Fin/Flange Picture PW-8150 Vinyl Fin/Flange Picture Window, Impact, WZ3 Window Limits of Use Installation Instructions Approved for use in HVHZ: No FL17387 R2 II CWS-1032B.pdf Approved for use outside HVHZ: Yes Verified By: Lucas A. Turner PE-58201 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: +60/-60 Evaluation Reports Other: PW-8150, Max, size 36" x 72", DP +/-60 PSF. Glass FL17387 R2 AE EvalReport1032B.pdf conforms to ASTM E1300-04. Created by Independent Third Party: Yes 17387.2 PW-8300 Vinyl Fin/Flange Picture PW-8300 Vinyl Fin/Flange Picture Window, Impact, WZ3 Window Limits of Use Installation Instructions Approved for use in HVHZ: No FL17387 R2 II CWS-1033B.pdf Approved for use outside HVHZ: Yes Verified By: Lucas A. Turner PE-58201 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: PW-8300, See Installation Detail for Max. Sizes and DR FL17387 R2 AE EvalReport1033B.pdf Glass conforms to ASTM E1300-04. Created by Independent Third Party: Yes Bacx Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: 12 El Wall eChec M Credit Card Safe \ .ennnei flnrirhhi i ilrlinn nrn/nr/nr nnn rltl acnv9nar .erIto/-9fR9r1PTlrlrll 7n0/'3rl0%'2rl 9/9 7: M O FI H PICTURE WINDOW - LARGE MISSILE IMPACT 37 1/4' MAX OVERALL FLANGE WIDTH 36' MAX. UNIT WIDTH 31 13116" GLASS DLO A I I „4" B I I I I I B O(. I ERALL I I ANGE IGHT I I 72' I I I I I MAX. I I I UNIT I I HEIGHT I I 67 13/16" GLASS I I I I � I B DLO 6 16 I I I D I I I TABLE OF CONTENTS GENERAL NOTES & ELEVATIONS.......1 ARCHITECTURAL SHAPES...................2 SECTION VIEWS & GLAZING................3 EXTRUSIONS & B.O.M...........................4 ANCHOR SCHEDULE & NOTES ............ 5 INSTALLATION DETAILS.......................6 A 6 GENERAL NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE FLORIDA BUILDING CODE (FBC), CURRENT EDITION AND IS RATED FOR WIND ZONE 3 MISSILE LEVEL D IMPACT USE AS DEFINED IN ASTM E 1996 PER THE FBC. THIS PRODUCT MAY NOT BE USED IN THE HIGH VELOCITY HURRICANE ZONE (HVHZ) OR IN ASTM E 1996 WIND ZONE 4 AREAS. 2. GLAZING OPTIONS: (SEE SHEET 3) 3. CONFIGURATIONS: "0". ARCHITECTURAL SHAPES INCLUDE, BUT ARE NOT LIMITED TO, THOSE SHOWN ON SHEET 2. 4. DESIGN PRESSURE RATING: -NEGATIVE DESIGN LOADS BASED ON, TESTED PRESSURE AND GLASS TABLES ASTM E-1300-04e01/09. -POSITIVE DESIGN LOADS BASED ON, TESTED PRESSURE, WATER INFILTRATION TEST PRESSURE AND GLASS TABLES ASTM E-1300-04e01/09. 5. ANCHORAGE: THE 331/3% STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT. SEE SHEET 6 FOR ANCHOR DETAILS. WINDLOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 6. PRODUCT APPROVED FOR IMPACT RESISTANCE. SHUTTERS ARE NOT REQUIRED. 7. ALL FRAMES ARE FULLY WELDED. 8. SERIES / MODEL DESIGNATION PW-8150. 9. THE DESIGNATION X AND 0 STAND FOR THE FOLLOWING: O = FIXED SASH. 10. SECTION CALLOUTS APPLY TO ALL ELEVATIONS IN A SIMILAR LOCATION. MAX. UNIT SIZE DESIGN PRESSURE RATING I IMPACT RATING 36" x 72" +/- 60 PSF LARGE MISSILE IMPACT Lucas Turner 2017-08-30 17:08+20:00 k ymmo Ul /11 1900 SW 44TH AVE. OCALA, FLORIDA 34474 W W W.CwS.Cc 8150 PVC PICTURE WINDOW IMPACT Q 3: ¢ZD 1- ow0 ¢wow Z Wes❑ w ZOZ 0'~-H o I-w zoi:2x Z Zx2¢wwoo O 0WW ILf-rnQ cn ? z Q 5 ZjU� UU(D Q-UWOo�z Z F- ,6 LU Oo�yoWOg W w d'tno WU1 W d �0-j/nI- 0 w�0 aUx�Y a a 5- X� 8/29/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 GENERAL NOTES AND ELEVATIONS EMK 1 10/06/14 CWS-1032 B CALE SHEET 1:15 1 OF 6 FULL CIRCLE ii!!: 11 1/2 CIRCLE 1/4 CIRCLE FULL ELLIPSE (OVAL) OCTAGON TRIANGLE TOMBSTONE TRAPEZOID NOTES: 1. SEE SHEET 5 FOR DETAILED ANCHOR INSTALLATION REQUIREMENTS. 2. THRU FRAME- MASONRY, WOOD OR METAL OPENING. THRU FIN - WOOD OPENING. 3. OVERALL SIZE MUST NOT EXCEED THE MAX. WIDTH AND HEIGHT OF RECTANGULAR WINDOW ON SHEET 1. 4. ANCHOR SPACING FOR ARCHITECTUAL FLANGE AND FIN WINDOWS MUST FOLLOW THE LAYOUTS SHOWN ON SHEET 5, WITH ANCHOR SPACING MEASURED ALONG THE LENGTH OF THE PRODUCT. WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA, FLORIDA 34474 W W W.CW S.CC 8150 PVC PICTURE WINDOW IMPACT a z � ¢Z� F OWO QwOW z WDO w zOz_ W—SF- 0 F-W�ZF-�22 Z Z=2<wwoo O owF-'mI.-wm Z ZO �ZjUN Q 1=�LLgOO-z < owp.=O— Fa 0o i LL 00J o> fA F- d 00 w1.-0 (L= fr _ af w�wrn a F- a Of a 8/29/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 ARCHITECTURAL SHAPES EMK 1 10/06/14 CWS-1032 B :ALE SHEET 1:1 2 OF 6 C509bm WINDOW SYSTEMSffl INTERIOR 1900 SW 44TH AVE. OCALA, FLORIDA 34474 www.cws.cc 7 - O 1 7 8150 PVC 10 10 PICTURE WINDOW QQ IMPACT lJ a z 3: ¢Z3 OLUO a~o w zOz w1=�W 7 0 zm§>-Ow�m 5 8 11 11 8 6 O ZM2<XWOO U 00, -Z O-H ti d C70 SECTION VIEW B-B z Z C71- Z~ m 1n OZOujZ�U- 3 C-LL2OOLLZ <QQyOwF.tzO- 7/8" OVERALL < Q F- y j 0 � a 3/16" ANNEALED 01 Z w m O � N H a co 11 3/8' AIR SPACE O w H it W S of a F- n of EL 5/16" LAMINATED 10 1 1!8' ANNEALED `�`1dOREW,to�i, .105 DUPONT PVB INTERLAYER �,PS✓'�GENy'rG•Q �i 118" ANNEALED -i No 58201 •: i1 INTERIOR * • * • 9 STATE OF 10 PURFECT GLAZE'H" OR SIKAFLEX 552 S�'L 10 1 '4ryStONA1 q&)- 1/2' GLASS BITE8 JI ��8/29/2017 2 OOO LUCAS A. TURNER, P.E. - - FL PE # 58201 0 _ 1239 JABARA AVE. NORTH PORT, FL 34288 7 OQO� PH. 941-380-1574 SECTION VIEW A -A O� SHEET DESCRIPTION: ALTERNATE FIN FRAME SECTION VIEWS AND 0 GLAZING DETAIL DRAWN BY: DATE* EMK 10/06/14 1:1 DWG REV, CWS-1032 B SCALE SHEET 1:2 3OF6 PARTS LIST DESCRIPTION SASH STOP SINGLE HUNG FIN FRAME SINGLE HUNG FLANGE FRAME HEAD LINE ITEMS NOT USED: 9 2 PVC FRAME, FLANGE - H-6049 3/16" 112"—i �r 3' -i p � 7 SCREW SUPPORT - P-3113 3 PVC FRAME, FIN - H-6048 A k-k-/tkk)X6( YY 6 WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA. FLORIDA 34474 www.CwS.CC 8150 PVC CORNER WELD (ALL SIDES) SCALE 1:6 PICTURE WINDOW IMPACT a ? ¢z0 Jm ¢F-ow z W W zOz 'f= z Zxnarrwoo Z zz �z�jU� ODU (Y F-U~Z W W lY LL 0wu)O u) a 0 wFF--� WOE(! 'L a X IL 16" 3/16" 1 5r16" _ 718" 1 1 7!8" 1 1/i6" tr16" PVC GLAZING BEAD - S-6064 PVC FILLER, SASH STOP - S-6025 zz 8/29/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 BOM AND EXTRUSIONS EMK 10/06/14 WG #: REV.: CWS-1032 B GALE: SHEET 1:1 4OF6 12' MAX OX 6- MAX (TYI 6- MAX (TYI 20' MAX O.C. (TYP.) ANCHORLAYOUT- (FLANGE) !2 INSTALLATION ANCHOR (TYP.) 4' MAX. 4" MAX. 6" MA (TY ANCHOR LAYOUT - (FIN) NOTES: 1. INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION. ANCHOR SPACING APPLIES TO ALL SHAPES (SEE SHEET 2) ALONG ALL FRAME EDGES. SILL ANCHOR SPACING SAME AS HEAD. 2. SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX. ALLOWABLE SHIM STACK TO BE 114". USE SHIMS WHERE SPACE GREATER THAN 1/16" IS PRESENT. LOAD BEARING SHIMS SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. WOOD SHIMS ARE NOT ALLOWED. 3. ANCHOR TYPE, SIZE, SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS, SEE TABLE 1, SHEET 6. 4. ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST BE PROTECTED TO PREVENT REACTION. 5. INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM SPECIFIED IN TABLE 1, SHEET 6. 6. ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS, EMBEDMENT SHALL BE BEYOND WOOD BUCKS, IF USED, INTO SUBSTRATE. INSTALLATIONS TO SOLID CONCRETE OR GROUT -FILLED CMU MAY INCLUDE BUT DO NOT REQUIRE 1X WOOD BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. 7. A MINIMUM CENTER -TO -CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS: 3" FOR MASONRY, 1" FOR WOOD AND METAL. B. WOOD OR MASONRY OPENINGS, BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET, SHEET 6. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. 9. SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: FMA/AAMA 100(FIN WINDOWS), FMA/AAMA 200(FLANGE WINDOWS), FMA/WDMA250(BOX WINDOWS), FMA/AAMA/WDMA300(EXTERIOR DOORS) cau wlNoow SYSTEMS ffl 1900 SW 44TH AVE. OCALA, FLORIDA 34474 W W W.CWS.CC 8150 PVC PICTURE WINDOW IMPACT Q �: QZowu D Lu W ZOZ_ of— F- LL :FcP W Z Q Z: O2_ 0 OHO¢¢ =�af 0 00I—ZQ-F-W CL oz��;ZsU(� I--'mo LLZ <QOw�FO_ Z(p W wowww 0 Jtnl- a O w�0 MX> a F= a ��wa zZ_ 8/29/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH.941-380-1574 ANCHOR SCHEDULE AND NOTES EMK 1 10/06/14 CWS-1032 B :ALE SHEET 1:1 5 OF 6 SUBSTRATE BY OTHER SEE TABLE 1 PERIMETER SEALANT - INSIDE AND OUTSIDE BYINSTALLER SEALANT BEHIND FLANGE BY INSTALLER INSTALLATION SEE TABLE 1 SEALANT BEHIND FLANGE BY INSTALLER PERIMETER SEALANT. - INSIDE AND OUTSIDE BYINSTALLER SUBSTRATE BY OTHER SEE TABLE 1 TYPICAL HEAD ANCHORAGE MIN. EDGE DIST. .. SEE TABLE 1 MIN. EMBEDMEI SEE TABLE 1 i 114" MAX SHIM MIN. EMBEDMENT SUBSTRATE BY OTHERS SEE TABLE 1 SEE TABLE 1 1/4' MAX. SHIM MIN. EDGE DIST. SUBSTRATE SEE TABLE 1 BY OTHERS 114" MAX. SHIM SEE TABLE 1 MIN. EDGE DIST. SEE TABLE 1 INSTALLATION ANCHOR - SEE TABLE 1 MIN. EMBEDMENT SEE TABLE 1 SEALANT UNDER SCREW HEAD BYINSTALLER 1/4" MAX SHIM MIN. EMBEDMENT SEE TABLE 1 MIN. EDGE DIST. SEE TABLE 1 CA� VERTICAL SECTION 6 TYPICAL SILL ANCHORAGE PERIMETER SEALANT INSIDE AND OUTSIDE BYNSTALLER SEALANT BEHIND FLANGE BYINSTALLER B HORIZONTAL SECTION 6 TYPICAL JAMB ANCHORAGE TABLE 1: APPROVED INSTALLATION FASTENERS FRAME TYPE SUBSTRATE TYPE ANCHOR TYPE MIN. EMBEDMENT MIN. EDGE DIST. FLANGE CONCRETE (2.0 KSI MIN.) 3116" ITW TAPCON 1-112" 1-1/8" FLANGE HOLLOW OR GROUT -FILLED CMU (117 PCF MIN.) 3/16" ITW TAPCON 1" 2" FLANGE CONCRETE (2.85 KSI MIN.) 3/16" ELCO ULTRACON 1" 1" FLANGE GROUT-FILLED"CMU (ASTM C-90) 3/16" ELCO ULTRACON 1-114" 2-1/2" FLANGE 2XMIN. SOUTHERN PINE (G=0.55) 3/16" ITW TAPCON OR ELCO ULTRACON 1-318" 718" FLANGE 2X MIN. SOUTHERN PINE (G=0.55) #10 WOOD SCREW 1-318" 718" FLANGE 16 GAUGE (0.060") MIN. STEEL STUD (33 KSI YIELD MIN) #10-16 HILTI KWIK-FLEXOR ITW TEKS SELF_ DRILLING SCREW FULL THREAD THRU 0.060" 7/16 FLANGE 1/8" ALUM. (6063-T5_ MIN.) OR 1/8" STEEL (33 KSI MIN.) - #10 GRADE 5 SELF -TAPPING J DRILLING SCREW FULL THREAD - THRU 0.125" - 7/16' . FIN 2XMIN. SOUTHERN PINE (G=0.55) #8 WOOD SCREW 1-1/2" 7/16" PERIMETER INSIDE AND BY INSTALLE PERIMETER SEALANT INSIDE AND OUTSIDE BYINSTALLER INSTALLATION ANCHOR SEE TABLE 1 SEALANT BEHIND FIN BY INSTALLER HORIZONTAL SECTION 6 TYPICAL FIN ANCHORAGE HEAD AND SILL SIMILAR FOR FIN INSTALLATION a0gogwim WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW.CWS.CC 8150 PVC PICTURE WINDOW IMPACT Q 3: ¢Z3r W O Z WZ H Qr ZZO Ho�>Om5m LL WZr�2= Z Z 2 2 a x W O O O Or0 IL Ir U —En Zf/Ja z Z 00 —Z? O— OO gQ rrrZ W l o w w o W o W 0JInr z— aof 0 o =rm Ill a r a � a El k 8/,2Z017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. HORIZONTAL SECTION NORTH PORT, FL 34288 6 BOX FRAME INSTALLATION PH. 941-380-1574 HEAD AND SILL SIMILAR FOR BOX INSTALLATION SHEET DESCRIPTION: INSTALLATION DETAILS FLANGE REMOVAL NOTE: PARTIALLY OR FULLY REMOVING THE FLANGE, DRAWN BY: DATE: UP TO AND INCLUDING A BOX -FRAME APPLICATION IS ACCEPTABLE PROVIDED: EMK 10/06/14 MIN. 1/4" FILLET OF CONSTRUCTION -GRADE ADHESIVE CAULK IS APPLIED DWGtt: REV.: INSIDE AND OUTSIDE. FULL PERIMETER, BY INSTALLER. CWS-1032 B PRODUCT ANCHORAGE IS IN ACCORDANCE WITH REQUIREMENTS AS SCALE SHOWN FOR FLANGE WINDOWS. SHEET 1:2 6 OF 6 Product Approval Method Method 1 Option A File COPY Date Submitted 01/28/2020 RECEIVED Date Validated 01/28/2020 Date Pending FBC Approval M NOV-0 6 2020 Date Approved 02/06/202R� dI IU Date Revised 07/3],, DE r OMPLIANG6it1a'mngDepaftm't 6�J�d.•j/ `\�C COUNTY St. LUcretounty Summary of Products ST.. LUCIE COUNTY FL # Model, Number or Name Descripti 13010.1 PW-8150 PVC Fixed Window PW-8150 PVC Fig/Fin Fixed Window Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL13010 RIO C CAC 138-1357 C1RO.pdf Approved for use outside HVHZ: Yes FL13010 R10 C CAC 138-1362 CIRO.pdf Impact Resistant: Yes FL13010 R1O C CAC 138-562 QRO.pdf Design Pressure: N/A Quality Assurance Contract Expiration Date Other: PW-8150, 36" x 72" and 72" x 76" see installation 09/14/2022 detail for DPs. Large Missile Impact. In HVHZ may only be used Installation Instructions up to 30ft above grade. Glass complies to ASTM E1300-04. FL13010 RIO II CWS-433D.pdf Verified By: Lucas A. Turner 58201 Created by Independent Third Party: No - Evaluation Reports FL13010 RIO AE EvalReport433D.pdf Created by Independent Third Party: Yes 13010.2 PW-8150 PVC Fixed Window PW-8150 PVC Flg/Fin Fixed Window, Continuous Head & Sill. Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL13010 R10 C CAC 138-261.pdf Approved for use outside HVHZ: Yes FL13010 RIO C CAC 138-705.pdf Impact Resistant: Yes FL13010 RIO C CAC 138-706.pdf Design Pressure: +67.5/-67.5 Quality Assurance Contract Expiration Date Other: Large Missile, Dp = +/- 67.5 psf, Max. size 74 1/8" x 08/12/2022 72". Outer, lite must be safety glass above 30 ft. in HVHZ. Glass Installation Instructions complies to ASTM E1300-04. FL13010 R10 II CWS-510C.pdf Verified By: Lucas A. Turner 58201 Created by Independent Third Party: No Evaluation Reports FL13010 R10 AE EvalReport510C.pdf Created by Independent Third Party: Yes 13010.3 ___ PW-8300 PVC Fixed Window PW-8300 PVC Fig/Fin Fixed Window, 120" x 48" Limits se Certification Agency Certificate roved for use in HVHZ: Yes FL13010 R10 C CAC CAR 138-258.pdf Approved for use outside HVHZ: Yes FL13010 R10 C CAC CAR 138-481.pdf Impact Resistant: Yes FL13010 R10 C CAC CAR 138-482.pdf Design Pressure: +70/-70 Quality Assurance Contract Expiration Date Other: PW-8300, 120" x 48", DP = +/ 70 psf. Large Missile 04/09/2022 Impact. Glass complies to ASTM E1300-04. Installation Instructions FL13010 R10 II CWS-373C.pdf Verified By: Lucas A. Turner, P.E. FL PE #58201 Created by Independent Third Party: No Evaluation Reports FL13010 RIO AE EvalReport373C.pdf Created by Independent Third Party: Yes 13010.4 PW-8300 PVC Fixed Window Series 8300 PVC Fixed Window, Large Missile Impact, 48" x 72" unit size - DP55, or 72" x 76" unit size - D067.5 (DP65 outside HVHZ) Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL13010 R10 C CAC 138-250 COR4.pdf Approved for use outside HVHZ: Yes FL13010 R10 C CAC 138-274 C1R0.pdf Impact Resistant: Yes FL13010 R10 C CAC 138-730 C1R0.pdf Design Pressure: N/A FL13010 R10 C CAC 138-739 C1RO.pdf Other: Sizes up to 48" x 72" unit size at design pressures of FL13010 R10 C CAC CAR 138-1093.pdf +/-55 psf, or in sizes up to 72" x 76" unit size at design FL13010 R10 C CAC CAR 138-1320 e2.pdf pressures of +/-67.5 psf in HVHZ or +/-65 psf outside the FL13010 R10 C CAC CAR 138-457.pdf HVHZ, with max. glass daylight sizes as shown in CWS-159E FL13010 R10 C CAC CAR 138-465.pdf Glass complies to ASTM E1300-04. FL13010 R10 C CAC CAR 138-534.pdf Quality Assurance Contract Expiration Date 04/29/2021 Installation Instructions FL13010 R10 II CWS-159E.pdf 1Anene1 flnrirlohi dirlinn nrn/nr/nr onn rift 14h=ro%9fZTn7n Fri9n%inQlRhnRPQ%Aio/ qr{o/ Z,{ 9/q I PICTURE WINDOW - LARGE MISSILE IMPACT 121 1/4" OVERALL FLANGE WIDTH 120" MAX UNIT WIDTH 117 1/8" GLASS DLO 49 114" OVERALL FLANGE 4MAX B UNIT I O HEIGHT 45 118' GLASS DLO 1 � I TABLE OF CONTENTS GENERAL NOTES & ELEVATIONS.......1 ARCHITECTURAL SHAPES...................2 SECTION VIEWS & GLAZING................3 EXTRUSIONS & B.O.M...........................4 ANCHOR SCHEDULE & NOTES ............ 5 INSTALLATION DETAILS.......................6 0 GENERAL NOTES: {ice 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED WINDOW SYSTEMS TO COMPLY WITH THE FLORIDA BUILDING CODE (FBC), CURRENT 1900 S44THFLORIDA E. 1900 SW 44TH AVE. EDITION INCLUDING THE HIGH VELOCITY HURRINCANE ZONE (HVHZ) OCAW 34474 AND IS RATED FOR WIND ZONE 4 MISSILE LEVEL D IMPACT USE AS W W.CW CC DEFINED IN ASTM E 1996 PER THE FBC. 2. GLAZING OPTIONS: (SEE SHEET 3) 8300 PVC 3. CONFIGURATIONS: "O". ARCHITECTURAL SHAPES INCLUDE, BUT ARE PICTURE WINDOW NOT LIMITED TO, THOSE SHOWN ON SHEET 2. IMPACT 4. DESIGN PRESSURE RATING: -NEGATIVE DESIGN LOADS BASED ON, TESTED PRESSURE AND GLASS TABLES ASTM E-1300-04e01/09. < Z 3' ¢ Z -POSITIVE DESIGN LOADS BASED ON, TESTED PRESSURE, WATER F O W O Q fw.. 0 w INFILTRATION TEST PRESSURE AND GLASS TABLES w Z O Z x~ F ASTM E-1300-04e01l09. 9 � 0 3� as5. LL w§i z ANCHORAGE: THE 33113 % STRESS INCREASE HAS NOT BEEN USED Z O Z x 2 ¢ w w 0 O OFO ¢ IN THE DESIGN OF THIS PRODUCT. SEE SHEET 6 FOR ANCHOR O O co 1--Z D- P U) as DETAILS. WINDLOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD 0 Z — U) Z O ANCHOR CALCULATIONS. ¢ O Z O U) Z z Q U I--W2p Z — ¢ O t 6. PRODUCT APPROVED FOR IMPACT RESISTANCE. SHUTTERS ARE NOT REQUIRED. Of � F 1"' Z ui x j3: w 0 > O 2 7. ALL FRAMES ARE FULLY WELDED. d LLmwNOw(nF Z = d 0 O — ( 8. SERIES / MODEL DESIGNATION PW-8300. O a wF0 IL 2: a LU i� w In 9 THE RAND O STAND FOR THE FOLLOWING: '10i��� O =FAXED SASH. P�jOREW 10. SECTION CALLOUTS APPLY TO ALL ELEVATIONS IN A SIMILAR 6 : y�0 ENgF:,�Qtiy� Zj " LOCATION. _ : No 58201 '�11 MAX. UNIT SIZE DESIGN PRESSURE RATING IMPACT RATING 120" X 48" +/- 70 PSF I LARGE MISSILE IMPACT LucasTurne r 2017-09-22 12:33-04:00 z� 9/22/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 GENERAL NOTES AND ELEVATIONS AWN BY: DATE: AIDE 05/05/07 /G#: REV.: CWS-373 C ALE: SHEET 1:20 1 OF 6 FULL CIRCLE in_ 112 CIRCLE 1/4 CIRCLE FULL ELLIPSE ("OVAL") OCTAGON TRIANGLE TOMBSTONE TRAPEZOID NOTES: 1. SEE SHEET 5 FOR DETAILED ANCHOR INSTALLATION REQUIREMENTS. 2. THRU FRAME - MASONRY, WOOD OR METAL OPENING. 3. OVERALL SIZE MUST NOT EXCEED THE MAX. WIDTH AND HEIGHT OF RECTANGULAR WINDOW ON SHEET 1. 4. ANCHOR SPACING FOR ARCHITECTUAL FLANGE WINDOWS MUST FOLLOW THE LAYOUT SHOWN ON SHEET 5, WITH ANCHOR SPACING MEASURED ALONG THE LENGTH OF THE PRODUCT. Gamsm 1900 SW 44TH AVE. OCALA, FLORIDA 34474 W W W.CWS.CC 8300 PVC PICTURE WINDOW IMPACT a z 3 "1zo i owO ¢waw Z W J ❑ W ZOZ W'�zF- u- I-w ZF-32x O OI=-O¢<¢w0W O OVj I- ZD-Hind Z p 5-�U(n - ¢�pwpre ?O? ui W LLU)wry OwlnW 2 Zia OJInF It wr0 (L= d F=- Iw 3 d No 58201 Z'P STATE OF c iI4Ss+ONA; 9/22/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 ARCHITECTURAL SHAPES AWN BY: DATE. ADE 05/05/07 JG 9: REV.: CWS-373 C ALE: SHEET 1:1 2 OF 6 INTERIOR SECTION VIEW A -A INTERIOR SECTION VIEW B-B QUANEX DURASEAL IG SPACER 1" OVERALL 1/4" TEMPERED 5116" AIRSPACE 7/16" LAM] GLASS 3116" HEAT STRENGTH .090 SENTRY GLASS IONOPLAST INTERLAYER 3/16' HEAT STRENGTH SIKAFLEX 552 OR PURFECT GLAZE'H" gal mmm Qm�mffl 1900 SW 44TH AVE. OCALA, FLORIDA 34474 W W W .0 W S.CC 8300 PVC PICTURE WINDOW IMPACT z 3 <ZO owo wwroo w zoz w=-L o FWZO3:�m 0 o�o¢aWpO O owI-ZaPwa z O o'-ZI-Uo Q 1 m0owZ > ¢Ow-=O_ w 2Q F- vt:Z wQ01 w w()0 w U) It z1O�nH QwO w aOw _ F- a �40 ,ti0RE4t, '10 �� P �cen�SFGpi �v No 56201 '�11 O: STATE 9/22/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 3428E PH. 941-380-1574 SHEET DESCRIPTION: SECTION VIEWS & GLAZING DETAIL ADE 05/05/07 JG #: REV.: CWS-373 C ALE: SHEET 1:1.33 3 OF 6 PARTS LIST ITEM PART # DESCRIPTION VENDOR MATERIAL 1 H-6006B Fr., PW, Main, Head Mikron PVC 2 H-6006B Fr., PW, Main, Sill Mikron PVC 3 H-6006B Fr., PW, Main, L. Jb. Mikron PVC 4 H-6006B Fr., PW, Main, R. Jb. Mikron PVC 5 S-6064 Glazing Bead (1" O.A. I.G.) Mikron PVC 6 P-3752 Cap Plug, 1/2" Hole M$M Nylon 7 Purfect Glaze "H", SikaFlex 552 Henkel / Sika Silicone 8 P-3352 Set. Blk., 85 Dur., 1/8" x 5/8".x 2" Lg. Frank Lowe Rubber 9 P-3684 PW-8300 Gold Cert. Label, NFRC Tab 10 P-3881 Temporary Lbl. (NFRC/DP) 11 P-3613 CWS Lbl. (logo) 12 GLASS SEE SHEET 3 Cardinal Glass 13 P-3113 IScrew Support for PVC Team Plastic I Rubber 2 1/16- N 3 118" �U 1/16" 1 7E!i—rililr PVC FRAME FLANGE - 6006B PVC GLAZING BEAD - 6064 i r 1/2" 1 3" 13 3/,6.r SCREW SUPPORT - 3113 FRAME CORNER CONSTRUCTION /LU1R®U WINDOWSYSTEMSB 1900 SW 44TH AVE. OCALA, FLORIDA 34474 W W W.CW S.CC CORNER WELD (ALL SIDES) 8300 PVC PICTURE WINDOW IMPACT t Z Zt ¢zo Ow0 ¢'ow Z wd Z o OZ>OwZm o-w�ZF-fig= U- z Zx2aww00 O 0 owoo-zm�-wm Z— w —ZF-Dy Z OOUcn �U— F?w20OLLZ w <QOwpFO— w Oww�owww Wa. Z=U-Wa w0wu~i O wl-w w=�� a a a3a dos"" tioREK,����i. r S,,VPS N. 58201 ••:�'A �70t STATE OF • 44;= i�T� •'P< O FI 1 O P,' ��a� i 9/22/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 BOM AND EXTRUSIONS ADE 05/05/07 JG #: REV.: CWS-373 C ALE: SHEET 1:1 4 OF 6 6" MAX (TYP.; 6• MAX. (TYP.] 9• MAX O.C. (TYP.) 9" MAX. O.C. (TYP.) SE r— — — — — — — — — — — — — — — — — — — — — — — — — — — — I I I I I I I I I I I O I I I I I I I L— — — — — — — — — — — — — — — — — — — — — — — — — — — — J ANCHORLAYOUT-(FLANGE) E NOTE 2 INSTALLATION ANCHOR (TYP.) NOTES: 1. INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION. ANCHOR SPACING APPLIES TO ALL SHAPES (SEE SHEET 2) ALONG ALL FRAME EDGES. SILL ANCHOR SPACING SAME AS HEAD. 2. SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX. ALLOWABLE SHIM STACK TO BE 114". USE SHIMS WHERE SPACE GREATER THAN 1/16" IS PRESENT. LOAD BEARING SHIMS SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. WOOD SHIMS ARE NOT ALLOWED. 3. ANCHOR TYPE, SIZE, SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS. SEE TABLE 1, SHEET 6. 4. ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST BE PROTECTED TO PREVENT REACTION. 5. INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM SPECIFIED IN TABLE 1, SHEET 6. 6. ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS, EMBEDMENT SHALL BE BEYOND WOOD BUCKS, IF USED, INTO SUBSTRATE. INSTALLATIONS TO SOLID CONCRETE OR GROUT -FILLED CMU MAY INCLUDE BUT DO NOT REQURE 1X WOOD BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. 7. A MINIMUM CENTER -TO -CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS: 3" FOR MASONRY. 1" FOR WOOD AND METAL. 8. WOOD OR MASONRY OPENINGS, BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET, SHEET 6. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. 9. SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: FMA/AAMA 100(FIN WINDOWS), FMA/AAMA 200(FLANGE WINDOWS), FMA/WDMA 250(BOX WINDOWS), FMA/AAMA/WDMA 300(EXTERIOR DOORS) 99mg 1900 SW 44TH AVE. OCALA, FLORIDA 34474 wwW.CWS.CC 8300 PVC PICTURE WINDOW IMPACT a z az37 I- OwO wwom Z W J 0 ZwOZ�}Ow3:m_ U. 1--WZF-3g= Z zx2¢�wp0 O 0U) za-I-cco5. Z ZO O7K Fs 0 C F-?LL200LLZ > QOf 2QOw_x0— I- O O I— >_ 2 w a of U)0 W mW ZW OJtnF o wF0 ILM as F a wed No 5S201 may: :x 59% STATE OF tW+ i�,n�'•'c� O R 1 p P; G�c��• SS+ONA������ z� 9/22/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 ANCHOR SCHEDULE & NOTES ADE ' 1 05/05/07 CWS-373 C ALE SHEET 1:20 5 OF 6 TYPICAL HEAD ANCHORAGE MIN. EMBEDMENT SEE TABLET SUBSTRATE BY OTHERS MIN. EDGE DIST. 1/4' MAX. SHIM SEE TABLE 1 SUBSTRATE BY OTHERS SEE TABLE 1 SEE TABLE 1 MIN. EDGE DIST. MIN. EMBEDMENT SEE TABLE 1 PERIMETER SEALANT SEE TABLE 1 BY INSTALLER INSTALLATION ANCHOR INSIDE AND OUT SEE TABLE 1 SEALANT BEHIND ❑� FLANGE BY INSTALLER �l 1l4' MAX SHIM INSTALLATION ANCHOR SEE TABLE 1 SEALANT FLANGE BY INSTALLER—\ fG7 �j���lJ Al = 1/4' MAX. SHIM IN9 DEEAND R I /A / I V/� MIN. E DME BYINSTALLESEE TABLE I SUBSTRATE BY OTHERS ' SEE TABLE 1 N. EDGE DIST. SEE TABLE 1 SEALANT UNDER SCREW— A VERTICAL SECTION HEAD BY INSTALLER 6 TYPICAL SILL ANCHORAGE TABLE 1: APPROVED INSTALLATION FASTENERS SUBSTRATE TYPE ANCHOR TYPE MIN. EMBEDMENT MIN. EDGE DIST. CONCRETE (2.0 KSI MIN.) 3/16" ITW TAPCON 1-1/2" 1-1/8" HOLLOW OR GROUT -FILLED CMU (117 PCF MIN.) 3/16" ITW TAPCON 1" 2" CONCRETE (2.85 KSI MIN.) 3116" ELCO ULTRACON - 1" 1" GROUT -FILLED CMU (ASTM C-90) 3116" ELCO ULTRACON 1-114" 2-112" 2XMIN. SOUTHERN PINE (G=0.55) 3/16" ITW TAPCON OR ELCO ULTRACON 1 3/8" 7/8" 2XMIN. SOUTHERN PINE (G=0.55) #10 WOOD SCREW 1-3/8" 7/8" 16 GAUGE (0.060") MIN. STEEL STUD (33 KSI YIELD MIN) #10-16 HILTI KW IK-FLEX OR ITW TEKS SELF -DRILLING SCREW FULL THREAD THRU 0.060" 7116" 1/8' ALUM. (6063-T5 MIN.) OR 1/8" STEEL (33:KSI MIN.)_ _ ` #10 GRADE 5 SELF -TAPPING ! DRILLING -SCREW - FULL THREAD - THRU 0.125' : - -- 7/t �— PERIMETER SEALANT BYINSTALLER INS DE AND OUT SEALANT BEHIND FLANGE BY INSTALLER B HORIZONTAL SECTION 6 TYPICAL JAMB ANCHORAGE PERIMETER SEALANT ll / / . BYINSTALLER INSIDE AND OUT C HORIZONTAL SECTION 6 BOX FRAME INSTALLATION HEAD AND SILL SIMILAR FOR BOX INSTALLATION FLANGE REMOVAL NOTE: PARTIALLY OR FULLY REMOVING THE FLANGE, UP TO AND INCLUDING A BOX -FRAME APPLICATION IS ACCEPTABLE PROVIDED: MIN. 1/4" FILLET OF CONSTRUCTION -GRADE ADHESIVE CAULK IS APPLIED INSIDE AND OUT, FULL PERIMETER, BY INSTALLER. PRODUCT ANCHORAGE IS IN ACCORDANCE WITH REQUIREMENTS AS SHOWN FOR FLANGE WINDOWS. 2000 1900 SW 44TH AVE. OCALA, FLORIDA 34474 www.cwS.CC 8300 PVC PICTURE WINDOW IMPACT Q 3�. ¢Z3: F- aw0 uu�o ¢w00 W Z O Z W_ z t O aU�}Ow�m U- F-w ZF-3:2T O OF-0¢¢woo U Uv1 �—zQ- tea V) Z ZQ j U - ¢ ZUUZOLL0 } 2 0 W0 2 0? ~U Zvi I~LI o(0 u)0wiow u_ w O�m!- a 0 w�0 woc� a a aka 10��`�Pp1ORE4V Op`?.��GENSFG-Pti No 58201 :*; } :*= ZO: STATE OF •4i: % z� 9/22/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH.941-380-1574 INSTALLATION DETAILS RAWN BY. DATE AIDE 05/05/07 WG k REV., CWS-373 C GALE` SHEET 1:2 6OF6 David Ward To: Richard Subject: BUILDERS If you can call them and tell them I will still be handling there account but because of all the Jobs that he cant set up the installs which will be your job and any service work that they need. Before you send it may I look at it. CAPP CONST -MICKEY OWNER-772-473-9710 MATT ROTH CONST 772-473-5656 RIC CAPP-772-473-1783 RANDY READ-772-473-5447 BILL JENITY-/IRPM 772-480-2332- DREW /IRPM RANDY HINES CONST-772-473-6076 Darwyn Jones <Darwyn@jonesandjonesinc.com 772-778-4152 RYAN JONES-772-766-4757 STEVE SUPPLE CONST-772-538-9486 JIM FORTIER /SEA OAKS-772-473-2043 BANOV CONSTRUCTION-772-299-6565 TRENDSETTERS/PAT772-633-6914 ALPHA CONST CJ772-913-3242 KB CONST KEITH-772-473-0865 KB CONST MARK BAKER-772-453-5970 WESTMARK-MIKE BAUER(FATHER OWNS COMPANY)-772- WESTMARK MIKE HUNLEY(RUNS THE SHOW)772-633-2900 MATHERNE CONST-DENNIS (OWNER)-772-473-0827 MATHERNE CONST (RUNS COMPANY) LARRY-772-569-4510 PATTON CONST-ANTHONY-772-473-1786 RIVERVIEW CONST-RONNIE-772-360-8678 CEMCO-ALI772-713-8499 DIRRICO CONST-FRED-772-473-0651 ED-EAS-772-559-2679 JC WELTON-CHRIS-772-473-3319 HCH CONST -CHRIS HARRINGTON-772-473-o690 I HAVE OTHERS BUT THIS IS A START DA-VIDOCENTRA L-WitDOW. COM CENTzAL WINDOW OF VERO gE,4Cff Ft- *3g8 NO1zTff WghwarJ, f vero beach fl 32�67 DA-VlD W�1ZD SALE.S JF-' DE<SI�N SINCE19j`�� j`z2--��2-�0800 Df12FCT LINF �j`z2--¢�3.335-¢ CALL JF.' TEXT WWW. CENT"L WINDO W. COM