Loading...
HomeMy WebLinkAboutChain Link Fencing Detail11f ) 1 CHIN LINK F NCIN G DETAIL ALL PROPOSED THESE PLANS AND ARE SUBJEC TO ANY CORRECTIONSOR . UIRED BY FIELD INSPECTORS THAT 1 REQ MAYBE WI H ALL APPLICABLE CO COMPL I i �f- w BUILDING DIV g ON MUS --... HI'D ps1rR v NO lN3pg� , gpr Ohf jog OR ON WILL 6g MgpE 9 ;E POST CAP CORNO f ENO POST TENSION SANG, TENSION BAR U ANSYNSPI-5 1995 protection to limit or delay access to the pool, spa or hot tub through doors or windows in the building/dwelling wall which provisions may, at the option of the local authority, be limited to dwellings where children less than five (5) years of age are permanent residents in the home. SECTION II - ADULT SUPERVISION Adult supervision of children at a residential swimming pool, spa or hot tub, or on said land where a residential swimming pool, spa or hot tub is installed shall be in accordance with all of the following provisions: 1. A person of reasonable intelligence and ability, at least eighteen (18) years of age, or, if less than eighteen (18) years old, with training in supervision such as Red Cross Life Guard certification. 2. A person supervising children at a swimming pool that is deeper than four feet (4') (1.2m) shall be proficient in swimming. 3. A person who shall be in the immediate vicinity of the pool, so that at all times the person shall have visual contact with the pool and/or the child/children he/she supervises and whose sole purpose at the pool, spa or hot tub is supervision and who shall not engage in physical activities not related to supervision. SECTION III - SUPPLEMENTAL LAYERS OF PROTECTION - OUTDOOR SWIMMING POOLS, SPAS, HOT TUBS Supplemental layers of protection for children at a residential swimming pool, spa or hot tub, or on said land where a residential swimming pool, spa or hot tub is installed shall be in accordance with the following provisions: 1. Walls, Fences and Structures as Barriers. Barrier walls and fences may be stand alone walls and fences or may be in combination with a structural pool, spa or hot tub walls, or a budding/dwelling wall to form the barrier around the swimming pool, spa or hot tub. 1.1. Dimensions. The top of the wall/fence shall be at least forty-eight inches (48") 1.2m) above grade measured on the side of the wall/fence which faces away from the swimming pool, spa or hot tub. The maximum vertical clearance between grade and the bottom of the wall/fence shall be four inches (4") (102mm). (See SECTION III, Paragraphs 2. through 2.3. for aboveground/nnground pool application). 1.2. Chain -link fence. Where a chain -link fence is provided as the barrier, the perpendicular distance between parallel sides of the link shall not exceed two and one -quarter inches (2-1/4") (57mm) which corresponds to a two and one -quarter inches (2 1/4") (57mm) mesh size for chain -link fencing as contained in specifications'for residential fencing of the Chain Link Fence Manufacturers Institute (CLFMI). (See Figure C). 13. Picket/ornamental fence. Where a picket/ornamental fence is provided as the barrier, the horizontal open-air spacing between pickets shall be a maximum of four inches (4") (102mm) between all vertical pickets and support posts. Where a picket/ornamental type fence is .provided, the maximum vertical opening between grade and the lowest part of the horizontal bottom rail of the fence shall not exceed a maximum of four inches (4") (102mm). Decorative detail shall not provide climbability. Minimum opening between decorative details shall be one and three quarter inches (1-3/4") (44mm) or greater. 1.3.1. Where the barrier is composed of horizontal and vertical members and the distance between the tops of the horizontal members is less than forty-five inches (45") (1.1 m), the horizontal members shall be located on the swimming pool side of the fence. Spacing between vertical members shall not exceed one and three-quarter inches (1-3/4") (44mm) in width. Decorative cutouts shall not exceed one and three-quarter inches (1-3/4") (44mm) in width. (See Figure A.) 1.3.2. Where the barrier is composed of horizontal and vertical members and the distance between the tops of the horizontal members is forty-five inches (45") (I.Im) or more, spacing between vertical members shall not exceed four inches (4") (102mm). (See Figure B). decorative cutouts shall not exceed one and three-quarter inches (1 3/4") (44mm) in width. 1.4. Pedestrian access grates. Access gates in the barrier shall comply with the requirements of SECTION III, Paragraphs 1.1. through 1.5., be self -closing, self -latching, accommodate a locking device and shall open outward away from the pool, spa or hot tub except when natural topography or other conditions dictate that it open inward. Release of the latch on the self -latching device for the gate shall be activated either: (a) at a height no less than fifty-four inches (54') (1372mm) above grade for chain -link access gates and at a height no less than fifty-four inches (54") (1372mm) above the horizontal bottom rail of a picket/omamental access gate, or, (b) on the pool, spa or hot tub side of the gate at a distance no less than three inches (Y) (76mm) below the top of the gate. (See Figure D). Where a self -latching device is also self- locking and is opened by means of a key, electronic opener, or integral combination lock, it maybe located at any height on the gate, so long as it does not negate the function of the gate; and said gate need not comply with 1.4.1. and 1.4.2. below. 38 ,ILE C,,,, OPY ANSIINSPI-5 1995 1.4.1 Chain -link access gate. Where the gate is a chain link -type, and where the release of the self -latching device is activated in accordance with Paragraph 1.4., alternative (b), there shall be no opening greater than one-half inch (1/2") (13mm) in diameter within eighteen inches (18") (457mm) of where the latch release is activated when the gate is closed. 1.4.2. Picket/ornamental access gate. Where the gate is a picket/ ornamental -type, such that the distance between vertical members is greater than one and three quarter inches (1-3/4') (44mm), and where the release of the self -latching device is activated in accordance with Paragraph 1.4. alternative (b), there shall be no opening in the gate/fence greater than one-half inch (1/2") (13mm) in diameter within'eighteen inches (18") (457mm) of where the latch release is activated when the gate is closed. (See Figure D). 1.5. Other access gates. Gates other than pedestrian access gates need not have a self - closing, self -latching feature but shall be provided with a means to secure the gate when it is not in use. 2. Pool Wall as Barrier for Aboveground/ Onground Pools. 2.1. Pool wall. An aboveground/onground pool wall, itself, may be the barrier if the pool structure is on grade and the wall is at least forty-eight inches (48") (1.2m) in height. Other types of barriers can be mounted on the pool structure or can be a barrier that surrounds the pool at ground level. Where the barrier is mounted on the pool structure, the maximum vertical clearance between the top of the pool structure and the bottom of the barrier shall be four inches (4") (102mm). Where an aboveground/ onground pool wall is less than forty-eight inches (48") (1.2m) above the ground, it is not considered a barrier and therefore, a barrier, in accordance with SECTION 111, Paragraph 1.1. through 1.5. shall be provided. 2.2. Ladders or stems. Where an aboveground/onground pool. structure is used as a barrier or where the barrier is mounted on the pool structure, and the means of access to the pool is a ladder or steps, then 2.2.1. the ladder or steps shall be capable of being secured, locked or removed to prevent access, or 2.2.2. the ladder or steps shall be surrounded by a barrier which meets the requirements of SECTION III, Paragraph 1.1. through 1.5., or 2.2.3. a lockable self -closing and self -latching gate at deck level shall be provided. 2.3. Fence rail mounted on top of forty-eight inch (48") (1.2m) aboveground/ onground pool wall structure. Where provided, the top rail of a pool fence, deck fence, patio fence, walk -around fence and gate, mounted on top of pool structure or deck of an aboveground/ onground pool which is in conformance with Paragraph 2.1., shall be a minimum of thirty-six inches (36") (914mm) above the deck surface. 23.1. Picket/ornamental-type fence. Where a picket/omamental-type fence is provided, maximum open air spacing between all vertical pickets and support posts (vertical) and between the top rail of the pool and the lower horizontal bottom rail of the fence shall not exceed four inches (4") (102mm). A sphere greater than four inches (4") (102mm) shall not pass through openings in the fence. 2.3.1.1. Visibilily. Where fencing is required and/or provided with the pool or deck, the fencing shall have at least 65% open area to allow visibility from outside to inside the pool area. 2.4. Deck. Where an aboveground/onground pool has a deck which abuts or is adjacent to a dwelling and direct access to the deck is through the exterior wall of the dwelling, such access shall be in accordance with Paragraph 3. 3. Wall of Building -with 3-sided Fencing as a Barrier. A wall of a building/dwelling may be used to form the barrier, or part of the barrier, as provided in SECTION III, Paragraphs 1. through 1.5. Paragraphs 3.1. through 3.2.3. shall apply to all residences with a swimming pool, spa or hot tub when a wall of a building/dwelling serves as a barrier to said swimming pool, spa or hot tub. The local authority shall have the option to restrict these requirements to only those residences where children less than five (5) years of age are permanent residents in the home. 3.1. Doors. Doors in the wall of a building/dwelling which allow direct access through the wall to the pool, spa or hot tub area shall be provided with one of the following: 39 1 L E C. 0 P'V'7 G (44mm) E E C m (102r J4 M " Max (102mm) FIG. A IF HORIZONTAL MEMBERS ARE LESS THAN 45" APART, THE SPACE BETWEEN VERTICAL MEMBERS SHALL NOT EXCEED 1-3/4". Self Latching Release mechanism E E E cE 1O Gate RELEASE MECHANISM LOCATED AT 54" OR HIGHER FROM THE BOTTOM OF THE GATE. (102mm) i /� 4" max I I � iP1 O Q o c e A W i E im) 3x I FIG. B IF HORIZONTAL MEMBERS ARE EQUAL TO OR MORE THAN 45" APART, THE SPACE BETWEEN VERTICAL MEMBERS SHALL NOT EXCEED 4': i7mm) 1/4" SQUARE CHAIN LINK MESH. IOMINAL) (13mm) Qpening (457mm) V2 max (76mm) Anti -Access .a- _._ 3" min Shield RELEASE MECHANISM LOCATED LESS THAN 54" FROM THE BOTTOM OF THE GATE. E i E f FIG. D LATCH RELEASE MECHANISM. 41 FILE COP-Y