HomeMy WebLinkAboutEnergy CodeFORM 60OA-2004R EnergyGaug*4.5-
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
Residential Whole Building Performance Method A
Project Name: ST. JOHNS INTERIOR UNIT Builder:
Address: Sa 14 ►rYto Permitting Office:
City, State: , 4 . rL, 344 51 Permit Number:
Owner: ELECTRIC Jurisdiction Number:
Climate Zone: Central
1. New construction or existing
New
2. Single family or multi -family
_
Single family
3. Number of units, if multi -family
I _
4. Number of Bedrooms
3
5. Is this a worst case?
_
Yes _
6. Conditioned floor area (ftz)
1912 ft2
7. Glass type I and area: (Label regd.
_
by 13-104.4.5 if not default)
a. U-factor:
Description Area
(or Single or Double DEFAULT) 7a(Sngle Default) 14LOW _
b. SHGC:
(or Clear or Tint DEFAULT)
7b. (Clear) 141.0 ftz
8. Floor types
a. Slab -On -Grade Edge Insulation
R=0.0, 153.0(p) ft
b. Raised Wood, Adjacent
R=19.0, 217.0ft2 _
c. N/A
9. Wall types
a. Frame, Wood, Exterior
R=11.0, 1702.0 ftz _
b. Concrete, Ext Insul, Exterior
R=4.1, 314.0 ftz _
c. Frame, Wood, Adjacent
R=11.0, 270.0 ftz _
d. N/A
e. N/A
10. Ceiling types
_
a. Under Attic
R=19.0, 1300.0 ftz
b. N/A
c. N/A
11. Ducts
_
a. Sup: Unc. Ret: Con. AH(Sealed):Interior
Sup. R=6.0, 175.0 ft
b. N/A
12. Cooling systems
a. Central Unit Cap: 42.5 kBtu/hr
SEER:13.00 _
b. N/A
c. N/A FILL� CO'rohY
13. Heating systems
a. Electric Heat Pump Cap: 42.5 kBtu/hr _
HSPF:7.90 _
b. N/A
c. N/A
14. Hot water systems
a. Electric Resistance
b. N/A
c. Conservation credits
(HR-Heat recovery, Solar
DHP-Dedicated heat pump)
15. HVAC credits
(CF-Ceiling fan, CV -Cross ventilation,
HF-Whole house fan,
PT -Programmable Thermostat,
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
Glass/Floor Area: 0.07 Total as -built points: 21133 PASS
Total base points: 23735
I hereby certify that the plans and specifications covered by
this calculation are in c mpliance with the Florida Energy
Code.
PREPARED
DATE: j
I hereby certify that this building, as des' ned, is in compliai
with the Florida Energy Code.
OWNER/AGENT:
DATE: 9 1 sl a
Cap: 50.0 gallons _
EF: 0.90
PT,
Review of the plans and
TflE S7,
specifications covered by this
calculation indicates compliance
o�
with the Florida Energy Code.
Before construction is completed
d
this building will be inspected for
a
compliance with Section 553.908
Florida Statutes.
wE
BUILDING OFFICIAL:
DATE:
1 Predominant glass type. For actual glass type and areas, see Summer & Winter Glass output on pages 2&4.
EnergyGauge® (Version: FLRCSB v4.5)
FORM 60OA-2004R EnergyGaugp,,r 4.5
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
I ADDRESS: , , , PERMIT #: I
BASE
AS -BUILT
GLASS TYPES
.18 X Conditioned X BSPM = Points
Overhang
Floor Area
Type/SC
Ornt
Len Hgt
Area X
SPM X SOF
= Points
.18 1912.0 24.35
8380.0
1.Single, Clear
E
1.0 8.0
48.0
63.97 0.99
3041.0
2.Single, Clear
E
1.0 6.0
40.0
63.97 0.97
2479.0
3.Single, Clear
W
1.0 6.0
16.0
57.68 0.97
893.0
4.Single, Clear
W
6.0 6.0
5.0
57.68 0.54
157.0
5.Single, Clear
W
1.0 6.0
32.0
57.68 0.97
1787.0
As -Built Total:
141.0
8357.0
WALL TYPES
Area X BSPM =
Points
Type
R-Value Area
X SPM =
Points
Adjacent
270.0 0.70
189.0
1. Frame, Wood, Exterior
11.0
1702.0
1.90
3233.8
Exterior
2016.0 1.90
3830.4
2. Concrete, Ext Insul, Exterior
4.1
314.0
0.48
150.7
3. Frame, Wood, Adjacent
11.0
270.0
0.70
189.0
Base Total:
2286.0
4019.4
As -Built Total:
2286.0
3573.5
DOOR TYPES
Area X BSPM =
Points
Type
Area
X SPM =
Points
Adjacent
18.0 1.60
28.8
1.Exterior Wood
20.0
7.20
144.0
Exterior
20.0 4.80
96.0
2.Adjacent Wood
18.0
2.40
43.2
Base Total:
38.0
124.8
As -Built Total:
38.0
187.2
CEILING TYPES
Area X BSPM =
Points
Type
R-Value
Area X SPM X SCM =
Points
Under Attic
1300.0 2.13
2769.0
1. Under Attic
19.0
1300.0 2.82 X 1.00
3666.0
Base Total:
1300.0
2769.0
As -Built Total:
1300.0
3666.0
FLOOR TYPES
Area X BSPM =
Points
Type
R-Value Area
X SPM =
Points
Slab 153.0(p) -31.8
-4865.4
1. Slab -On -Grade Edge Insulation
0.0
153.0(p
-31.90
-4880.7
Raised
217.0 -3.43
-744.3
2. Raised Wood, Adjacent
19.0
217.0
1.00
217.0
Base Total:
-5609.7
As -Built Total:
370.0
-4663.7
INFILTRATION
Area X BSPM =
Points
Area X SPM =
Points
1912.0 14.31
27360.7
1912.0
14.31
27360.7
EnergyGauge® DCA Form 60OA-2004R EnergyGauge®/FIaRES'2004 FLRCSB v4.5
FORM 60OA-2004R EnergyGauge�_�R 4.5
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
I ADDRESS:. , , PERMIT #: I
BASE
AS -BUILT
Summer Base Points: 37044.2
Summer As -Built Points:
38480.7
Total Summer X System = Cooling
Total X Cap
X Duct X System X
Credit =
Cooling
Points Multiplier Points
Component Ratio
Multiplier Multiplier
Multiplier
Points
(System - Points)
(DM x DSM x AHU)
(sys 1: Central Unit 42500btuh ,SEER/EFF(13.0) Ducts:Unc(S),Con(R),Int(AH),R6.0(INS)
38481 1.00
(1.08 x 1.150 x 0.85) 0.260
0.950
10083.8
37044.2 0.3250 12039.4
38480.7 1.00
1.061 0.260
0.950
10083.8
EnergyGauge"m DCA Form 60OA-2004R EnergyGauge®/FIaRES'2004 FLRCSB v4.5
FORM 60OA-2004R I EnergyGaug&:-) 4.5
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
I ADDRESS: , , , PERMIT #:
BASE
AS -BUILT
GLASS TYPES
.18 X Conditioned
X BWPM =
Points
Overhang
Floor Area
Type/SC
Ornt Len Hgt
Area X WPM X WOF = Point
.18 1912.0
9.11
3135.0
1.Single, Clear
E 1.0 8.0
48.0 12.37 1.01
596.0
2.Single, Clear
E 1.0 6.0
40.0 12.37 1.01
499.0
3.Single, Clear
W 1.0 6.0
16.0 13.25 1.00
212.0
4.Single, Clear
W 6.0 6.0
5.0 13.25 1.08
71.0
5.Single, Clear
W 1.0 6.0
32.0 13.25 1.00
425.0
As -Built Total:
141.0
1803.0
WALL TYPES
Area X
BWPM
= Points
Type
R-Value
Area X WPM =
Points
Adjacent
270.0
1.80
486.0
1. Frame, Wood, Exterior
11.0
1702.0 2.00
3404.0
Exterior
2016.0
2.00
4032.0
2. Concrete, Ext Insul, Exterior 4.1
314.0 2.36
741.0
3. Frame, Wood, Adjacent
11.0
270.0 1.80
486.0
Base Total:
2286.0
4518.0
As -Built Total:
2286.0
4631.0
DOOR TYPES
Area X
BWPM
= Points
Type
Area X WPM =
Points
Adjacent
18.0
4.00
72.0
1.Exterior Wood
20.0 7.60
152.0
Exterior
20.0
5.10
102.0
2.Adjacent Wood
18.0 5.90
106.2
Base Total:
38.0
174.0
As -Built Total:
38.0
258.2
CEILING TYPES Area X
BWPM
= Points
Type
R-Value Area X WPM X WCM =
Points
Under Attic
1300.0
0.64
832.0
1. Under Attic
19.0
1300.0 0.87 X 1.00
1131.0
Base Total:
1300.0
832.0
As -Built Total:
1300.0
1131.0
FLOOR TYPES
Area X
BWPM
= Points
Type
R-Value
Area X WPM =
Points
Slab 153.0(p)
-1.9
-290.7
1. Slab -On -Grade Edge Insulation 0.0 153.0(p 2.50
382.5
Raised
217.0
-0.20
-43.4
2. Raised Wood, Adjacent
19.0
217.0 1.00
217.0
Base Total:
.334.1
As -Built Total:
370.0
599.5
INFILTRATION
Area X
BWPM
= Points
Area X WPM =
Points
1912.0
-0.28
-535.4
1912.0 -0.28
-535.4
EnergyGauge® DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5
FORM 60OA-2004R EnergyGaur ..® 4.6
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT #:
BASE
AS -BUILT
Winter Base Points:
7789.5
Winter As -Built Points:
7887.4
Total Winter X System =
Heating
Total X Cap
X Duct X System X
Credit
= Heating
Points Multiplier
Points
Component Ratio
Multiplier Multiplier
Multiplier
Points
(System - Points)
(DM x DSM x AHU)
(sys 1: Electric Heat Pump 42500 btuh ,EFF(7.9) Ducts: Unc(S),Con(R),Int(AH),R6.0
7887.4 1.000
(1.068 x 1.160 x 0.87) 0.432
0.950
3505.1
7789.5 0.5540
4315.4
7887.4 1.00
1.083 0.432
0.950
3505.1
EnergyGaugeT" DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5
J
FORM 60OA-2004R EnergyGauge,p 4.5..
Code Compliance Checklist
Residential Whole Building Performance Method A - Details
I ADDRESS: , , , PERMIT #:
6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST
COMPONENTS
SECTION
REQUIREMENTS FOR EACH PRACTICE
CHECK
Exterior Windows & Doors
606.1.ABC.1.1
Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area.
Exterior & Adjacent Walls
606.1.ABC.1.2.1
Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall;
foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility
penetrations; between wall panels & top/bottom plates; between walls and floor.
EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends
from, and is sealed to, the foundation to the top plate.
Floors
606.1.ABC.1.2.2
Penetrations/openings >1/8" sealed unless backed by truss or joint members.
EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed
to the perimeter, penetrations and seams.
Ceilings
606.1.ABC.1.2.3
Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases,
soffits, chimneys, cabinets sealed to continuous air barrier, gaps in gyp board & top plate;
attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is
installed that is sealed at the perimeter, at penetrations and seams.
Recessed Lighting Fixtures
606.1.ABC.1.2.4
Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a
sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from
conditioned space, tested.
Multi-storyHouses
606.1.ABC.1.2.5
Air barrier on perimeter of floor cavity between floors.
Additional Infiltration reqts
606.1.ABC.1.3
Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA,
have combustion air.
6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.)
COMPONENTS
SECTION
REQUIREMENTS
CHECK
Water Heaters
612.1
Comply with efficiency requirements in Table 612.1.ABC.3.2. Switch or clearly marked cir
breaker electric or cutoff as must be provided. External or built-in heat trap required.
Swimming Pools & Spas
612.1
Spas & heated pools must have covers (except solar heated). Non-commercial pools
must have a pump timer. Gas spa & pool heaters must have a minimum thermal
efficient of 78%.
Shower heads
612.1
Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG.
Air Distribution Systems
610.1
All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically
attached, sealed, insulated, and installed in accordance with the criteria of Section 610.
Ducts in unconditioned attics: R-6 min. insulation.
HVAC Controls
607.1
Separate readily accessible manual or automatic thermostat for each system.
Insulation
604.1, 602.1
Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides.
Common ceiling & floors R-11.
EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE SCORE* = 87.8
The higher the score, the more efficient the home.
ELECTRIC, , , ,
1. New construction or existing
New
2. Single family or multi -family
_
Single family _
3. Number of units, if multi -family
I
4. Number of Bedrooms
3
5. Is this a worst case?
_
Yes
6. Conditioned floor area (ftz)
_
1912 ftz
7. Glass type and area: (Label reqd. by 13-104.4.5
_
if not default)
a. U-factor: Description Area
(or Single or Double DEFAULT) 7a(Sngle Default) 141.0 ftz _
b. SHGC:
(or Clear or Tint DEFAULT) 7b.
(Clear) 141.0 ft' _
8. Floor types
a. Slab -On -Grade Edge Insulation
R=0.0, 153.0(p) ft
b. Raised Wood, Adjacent
R=19.0, 217.0ft2 _
c. N/A
9. Wall types
a. Frame, Wood, Exterior
R=11.0, 1702.0 ft' _
b. Concrete, Ext Insul, Exterior
R=4.1, 314.0 ft2 _
c. Frame, Wood, Adjacent
R=11.0, 270.0 ft' _
d. N/A
e. N/A
10. Ceiling types
a. Under Attic
R=19.0, 1300.0 ftz _
b. N/A
c. N/A
11. Ducts
a. Sup: Unc. Ret: Con. AH(Sealed):Interior
Sup. R=6.0, 175.0 ft
b. N/A
12. Cooling systems
a. Central Unit
b. N/A
c. N/A
13. Heating systems
a. Electric Heat Pump
b. N/A
c. N/A
14. Hot water systems
a. Electric Resistance
b. N/A
c. Conservation credits
(HR-Heat recovery, Solar
DHP-Dedicated heat pump)
15. HVAC credits
(CF-Ceiling fan, CV -Cross ventilation,
HF-Whole house fan,
PT -Programmable Thermostat,
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
I certify that this home has complied with the Florida Energy Efficiency Code For Building
Construction through the above energy saving features which will.be installed (or exceeded)
in this home before final inspection. therwise, a new EPL isplay Card will be completed
based on installed Code compli features.
Builder Signature: Date:
Address of New Home: _�53k 14 t �.,� _ City/FL Zip: • P p , FL
Cap: 42.5 kBtu/hr
SEER: 13.00
Cap: 42.5 kBtu/hr _
HSPF: 7.90
Cap: 50.0 gallons
EF: 0.90
PT,
y�y01 TiiB ST,gyAo�.t
a
• c
*NOTE. The home's estimated energy performance score is only available through the FLARES computer program.
This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPA/DOE EnergyStarTmdesignation),
your home may qualms for energy efficiency mortgage (EEM) incentives ifyou obtain a Florida Energy Gauge Rating.
Contact the Energy Gauge Hotline at 3211638-1492 or see the Energy Gauge web site at www.fsec. ucf edu for
information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building
Construction, contact the Department of Community Affairs at 8501487--1824.
1 Predominant glass type. For actual glass type and areas see Summer & Winter Glass output on ages 2&4.
KnergyGauge® (Version: F It 89 v4.5)
+wrigh oft- Project Summary
04,,ght"tt Entire House
Proi ��.. _ect.Information
For: ST. JOHN'S INTERIOR
saI(+ s
Notes:
Job:
Date: Mar 24, 2007
By: G.CARMACK
Design Information a -
Weather: Fort Pierce, FL, US
Winter Design Conditions
Outside db
42 OF
Inside db
70 OF
Design TD
28 OF
Heating Summary
Structure
23376 Btuh
Ducts
2338 Btuh
Central vent (100 cfm)
3077 Btuh
Humidification
0 Btuh
Piping
0 Btuh
Equipment load
28791 Btuh
Infiltration
Method Simplified
Construction quality Average
Fireplaces 0
Area (ft2)
Heatingg
1912
Coolingg
1912
Volume (ft3)
16598
16598
Air changes/hour
0.38
0.20
Equiv. AVF (cfm)
105
55
Heating Equipment Summary
Make TEMPSTAR
Trade HEAT PUMP
Model N2H342AKD
Efficiency
Heating input
Heating output
Temperature rise
Actual air flow
Air flow factor
Static pressure
Space thermostat
7.9 HSPF
0
Btuh @ 47°F
0
OF
1353
cfm
0.053
cfm/Btuh
0.60
in H2O
Summer Design Conditions
Outside db
Inside db
Design TD
Daily range
Relative humidity
Moisture difference
90 OF
75 OF
15 OF
L
50 %
61 gr/lb
Sensible Cooling Equipment Load Sizing
Structure
25285
Btuh
Ducts
2529
Btuh
Central vent (100 cfm)
1649
Btuh
Blower
0
Btuh
Use manufacturer's data
n
Rate/swing multiplier
0.95
Equipment sensible load
27989
Btuh
Latent Cooling Equipment Load Sizing
Structure
3511
Btuh
Ducts
2544
Btuh
Central vent (100 cfm)
4177
Btuh
Equipment latent load
10233
Btuh
Equipment total load
38222
Btuh
Req. total capacity at 0.77 SHR
3.0
ton
Cooling Equipment Summary
Make TEMPSTAR
Trade HEAT PUMP
Cond N2H342AKD
Coil FEM2X4200
Efficiency
13 SEER
Sensible cooling
32725
Btuh
Latent cooling
9775
Btuh
Total cooling
42500
Btuh
Actual air flow
1353
cfm
Air flow factor
0.049
cfm/Btuh
Static pressure
0.60
in H2O
Load sensible heat ratio
0.74
Boldrfalic values have been manually overridden
Printout certified by ACCA to meet all requirements of Manual J 8th Ed.
wr10Ntsoft Right -Suite Residential 6.0.90 RSR21115 2007Sep-05 13:15:38
ACCA C:1Documents and SettingslgcarmacklMy DocumentslMan J Calcs 2007\FT.PIERCE\ST. JOHN'S INTERIOR.rrp Page 1
P4
,t
wrightsoft, Building Analysis
,.„. Entire House
Job:
Date: Mar 24, 2007
By: G.CARMACK
9
. 4Pro'ecf nforrnati on,
s.
-.-
Location:
Fort Pierce, FL, US
Indoor:
Indoor temperature (OF)
Heating
70
Cooling
75
Elevation: 25 ft
Latitude: 27°N
Design TD (°F)
Relafive humidity (%)
28
30
15
50
Outdoor: Heating
Cooling
Moisture difference (gr/lb)
1.1
61.5
Dry bulb (OFF 42
Daily range OF) -
90
15 ( L
Infiltration:
) Method
Simplified
Wet bulb (° -
78
Construction quality
Average
Wind speed ()mph) 15.0
7.5
Fireplaces
0
•
Component
Btuh/ft2
Btuh
% of load
Walls
2.8
6455
22.4
Glazing
35.6
5014
17.4
Doors
10.9
415
1.4
Ceilings
1.4
2125
7.4
Floors
10.6
6132
21.3
Infiltration
1.3
3235
11.2
Ducts
2338
8.1
Piping
0
0.0
Humidification
0
0.0
Ventilation
3077
10.7
Adjustments
0
Total
28791
100.0
UlErio
r° , . COO1i'n4j` ..
Component
Btuh/ft2
Btuh
% of load
Walls
2.5
5787
19.6
Glazing
89.5
12624
42.8
Doors
11.3
430
1.5
Ceilings
2.6
3985
13.5
Floors
0.3
168
0.6
Infiltration
0.4
912
3.1
Ducts
2529
8.6
Ventilation
1649
5.6
Internal gains
1380
4.7
Blower
0
0.0
Adjustments
0
Total
29462
100.0
Overall U-value = 0.158 13tuh/ft22F
WARNING: suspicious slab -on -grade floor perimeter in BDR #3.
;.� WI-10ht:S0'Ft Right -Suite Residential 6.0.90 RSR21115 2007Sep-05 13:15:38
ACCA C:IDocuments and SettingslgcannacklMy DocumentslMan J Calcs 20071FT.PIERCEIST. JOHN'S INTERIOR.rrp Page 1
•