HomeMy WebLinkAbout9616 CROOKED STICK LANE, PSL, FL 34986 PERMIT APPLICATIONAll APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED
Date: 11 /11 /2020
Permit Number:
9v" LUME
U ° n Building Permit Application
Planning and Development Services
Building and Code Regulation Division Commercial Residential X
2300 Virginia Avenue, fort Pierce Ft 34982
Phone. (772) 462-1553 Fax: (772) 462-1578
PERMIT APPLICATION FOR:TANKLESS GAS WATER NEATER INSTAL
PROPOSED IMPROVEMENT LOCATION:
Address: 9616 CROOKED STICK LANE, PORT SAINT LUCIE, FL 34986
Property Tax ID #: 3327-711-0015-000-4 Lot No. 8
Site Plan Name: POD 18 AT THE RESERVE PUD Il (PB 40-16) LOT 8 (OR 4108-2664) Block No.
Project Name: Sec/Town/Range: 27/36S/39E
DETAILED DESCRIPTION OF WORK:
NAVIAN 240-A PROPANE GAS TANKLESS WA I EK HLA i LK INN i Hi_i-H i 1UN
New Electrical Meter N/A Second Electrical MeterN/A
CONSTRUCTION INFORMATION:
Additional work to be performed under this permit— check all that apply:
Mechanical ^ Gas Tank —Gas Piping _ Shutters Windows/Doors Pond
Electric Plumbing , Sprinklers — Generator Roof Pitch
Total Sq. Ft of Construction: Sq. Ft. of First Floor:
Cost of Construction: $ 4976.75 Utilities: —Sewer __ Septic Building Height:
OWNER/LESSEE:
Name DAN FINLEY
Address:9616 CROOKED STICK LANE
City. PORT SAINT LUCIE State:
Zip Code: 34986 Fax:772-871-9069
Phnna Nn_ 772-871-9494
E-Mail: PERMITS u@BENFRANKLINPLUMBER.COM
Fill in fee simple Title Holder on next page ( if different
from the Owner listed above)
CONTRACTOR:
Name: MATT BLACK
Company:BENJAMIN FRANKLIN PLUMBING
Address:6945 NW LTC PARKWAY
City: PORT SAINT LUCIE State: FL
Zip Code: 34986 Fax: 772-871-9069
Phone No772-871-9494
E-Mail PERMITS@BEN FRANKLINPLUMBER.COM
State or County License CFC-1 430437
If value of construction is 2500 or more$ a RECORDED Notice of Commencement is required.
If value of HAVC Is $7,500 or more, a RECORDED Notice of Commencement Is required.
SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION:
DESIGNER/ENGINEER: x Not Applicable
Name:_
Address:
City:
Zip:
Phone
State
FEE SIMPLE TITLE HOLDER: x Not Applicable
Name:_
Address:
City:_
Zi p:
Phone:
MORTGAGE COMPANY: x Not Applicable
Name:_
Address:
City: State:
Zip: Phone:
BONDING COMPANY: X Not Applicable
Name:
Address:
City:
Zip: Phone:
OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated.
I certify that no work or installation has commenced prior to the issuance of a permit.
St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure
which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such
structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply.
In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work
in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review: room additions,
accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use
WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in paying twice for
improvements to your property. A Notice of Commencement must be recorded in the public records of St.
Lucie County and posted on the jobsite before the first inspection. If you intend to obtain financing, consult
with lender or an attorney before commencingwork or recording our Notice of Commencement.
Signature of Ownel Lessee/Contractor as Agent for Owner Signature of Contractor/License Holder
STATE OF FLORIDA STATE OF FLORIDA
COUNTY OF S� L[ICJ_C COUNTY OF
Swgrn to (or affirmed) and subscribed before me of Swofn to (or affirmed) and subscribed before me of
Physical Presence or Online Notarization / Physical Presence or Online Notarization
this < < day of AlaL%MhW , 2020 by this _ . day of 1V19V'Gir} 2020 by
Name of person making statement. Name of person making statement.
Personally Known %/ OR Produced Identification Personally Known _�/ OR Produced Identification
Type of Identification Type of Identification
Produced Produced
(S natur o ry u !E uL (Sign6ftur PNu i f44Mda )
o ry pu is - ate of Florida
• Notary public - State of Flo da Commission ! HH 49824
M Comm. Ex Tres Oct 1 20 I)
Commissi Commission p HH 49824Se Commissi t
^•�` omm.pires Oct 1, 2424 on ed through National Notary Assn.
Bonded through National Notary Assn, -
REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE
COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW
DATE
RECEIVED
DATE
COMPLETED
NavieNb
N PE Series
Condensing
Tan kless
Water Heaters
Navien make
it easy to
go tankless in
residential anc
commercial
applications
N PE -Advanced
.�. .�. High -efficiency Button.
_ condensing Optional on -demand NPE-A
_ tankless recirculation accessory
water heaters At the push of a 'i-
,'� y button, the Navien wr f
with built-in HotButton hot water
recirculation system activates the internal
Srecirculation pump and gas
system t�
th
fired burner to heat up e E ,
1
UP TO LIP TO water in the supply lines.
®0.971 Q.96i This gives your customers
hot water when they need
BE$IOElfRCIAL �w we CUMMECIAL It, saving water and money.
f � • California Title 24 compliant.
•Endless hot water with our dual stainless steel
heat exchangers
• Up to 80% smaller than tank water heaters
•Simpler retrofit with 2" PVC venting
*Simpler retrofit with 1/2" gas lines (subject to local code)
-one of the industry's strongest warranties
-Cascading up to 16 units and common venting
up to 8 units
-NaviLink'" compatible
floW
NPE-A internal
recirculation system*
Navien ComfortFlow is the first system that
incorporates a built-in insulated buffer tank and
recirculation pump. The buffer tank eliminates the
"cold water sandwich" effect commonly found
in other tankless water heaters. The
+� - recirculation pump saves on your water
IS bills by reducing time to get hot water.
*When activated, the ComfortFlow modo results in higher energy usage.
H2
For combination space heating
and domestic hot water
An innovative use for the NPE-A's integrated circulator,
designed for both retrofit and new construction
residontial applications. Navien's HAW' Kit*
consists of an add -on controller that allows for space
heating and DHW system integration between
NPE-A Series tankless water heater models and
a hydronic air handler.
*Compatible with NPE-A series units produced on or after
May 31. 2014.
Haviem,
NPE-Standard
When it
comes to
water heater
performance,
it's all about
the output
The NPE-S condensing
tankless water heaters
are so efficient that they
outperform much larger
capacity non -condensing
competitors. More output
for the money, lower
installation costs and
lower operating costs
for customers makes It
a smart choice.
Ultra
condensing
tankless
technology with
the industry's
top energy
efficiency rating
OOPS
"�PF-g
RESIOfMTfAL&
wwww e"
COMMERCIAL
*High -efficiency, up to 0.99 EF/0.97 UEF
*Endless hot water with our dual stainless steel
hea' exchangers
• Up to 80% smaller than tank water heaters
•Simpler retrofit with 2" PVC venting
-Simpler retrofit with 1/2" gas lines (subject to local
code)
-One of the industry's strongest warranties
-Cascading up to 16 units and common venting
up to 8 units
-NaviLink compatible
Navien NPE-5 condensing tankless water heaters
outperformed non -condensing comparably priced units
OUTPUT.-1131000 BTU/N�
-- Non-Contisnsing I
Tankless Condensing Tankless
Input 199,000 BTU/H
} Uniform Energy Factor (UEF) —0.81 0.97
ZIM 1 Output —163,000 -
Max GPM 9.8
0 List Price - $$
i=F 1 Installation Time —4-8 Hours 4 Hours
j —
J p Venting Other type (not PVC)VC
- .
w v Gas Pipe Typically 3/4' pipe
- ...
Overall Your Choice?
for
Ready- U W'
Commercial DHW wall
or rack modular manifold
mounting systems
30 possible configurations
Simply build
your manifold
installation from
our easy to
install modular
kits. Designed
to simply save
contractors time.
-Simply no waiting
for factory racks
-Simply easy to
install ... same day
*Simply more profitable
Simply visit your local Navien wholesaler and
pick up everything you need
As simple as 1-2-3-4
1 Pick your Navien Unit, Pick your location,
NPE-A or NPE-S wall or rack
�- Pick your matching Pick your venting
manifold kit(s) configuration
tj- U L • L.
wall
Side -by -side
in2,3or4
unit modules
Rack
Side -by -side j
in 2, 3 or 4 ,
unit modules t
Rack
Back-to-back
in2or4
unit modules
4rt
W
�k
�411
NaV1eN-
Innovation makes Navien
the professional's choice
for residential and
commercial applications
-Building owners and managers appreciate the
efficiency, reliability and durability of Navien condensing
tankless water heaters over outdated tank systems
*Architects and designers appreciate the space saving
design and the flexibility in configurations
l
t
F7
A
jr
• Commercial and residential builders add customer
pleasing technology that sets them apart from older,
more traditional water heating systems
-Contractors can save hours of installation by using
economical PVC venting and Navien's Ready -Link
commercial domestic hot water manifold system for
wall or free standing rack mounted units
• Having one of the industry's strongest commercial
warranties and customer support gives everyone
more peace of mind
NaV142N`
NPE Series
Cascade up to 16 units and
common vent up to 8 units
With Navien cascading technology, when a unit gets
up to 75% capacity the next unit will turn on to help
meet requirements and continue until all 16 units
are activated. Navien cascading system also
balances the
workflow of each
unit for long life. -
Wall penetrations
are reduced with
Navien's common
venting feature. I? UP I116 C'
Link.
Optional Wi-Fi
remote control system
NaviL.ink makes it easy to communicate with
bnk your Navien systems anywhere internet service
is accessible. The Navil_ink module attaches
easily to any new or existing* Navien NPE Series tankless
water heaters. Once installed, simply download the
free app on your smartphone or tablet. Then you
will be able to turn your unit on or off, change the
water temperature, monitor system status
and even activate the recirculation
system on your NPE-A tankless water
heater with an installed HotButtonr" kit.
*Existing installations may require the purchase of a new main PCB
and front control panel.
Temperature rise
;oM rh
M
- -
am
_ Igo mug
GPM
iiia""s
GPM
GPM
85
6.8
8.4
10.1
11.2
-
40
5-9
7.4
8.8
9.8
46
6.3
6.5
7.8
8.7
50
4-8
5.9
7.1
7.8
55
4.3
5.3
6.4
7.1
00
4.0
4.9
5.9
6.5
65
3.7
4.5
5.4
6.0 _
70
3.4
4.2
5.0
5.6
75
3.2
3.9
1 4.7
5.2
8o
3,0
3.7
4.4
4.9
8S
2.8
2.6
-- 2.4
2.2
3.5
3.3
2.9
2.7
4.2
3.9
3.5
3.2
4.6
4.4
3.9 -
3.6 -
gp
- 100 -
110�
120
2.0
2.5
2.9
1 3.3�
130
1,8
2.3
2.7
3.0
140
1.7
1 2.1
1 2.5
1 2.8
DHW capacity
Modals Natural gas (STU/M) Propans Oaa (BTU/H) t
NPE-150S
18,000-120,000
18,000-120,000
NPE-1B0 ASS
15,000-1507000
15,00D-150,000
NPE- 110A/S
19900-180,DD0
19,9w-180,000
NPE -240A/S
19,900-199,900
19,900-199,900
Warranty
Appiiostion Recirculation Labor Parts Haut
- - Staridard or controlled 1 yew 5 years 15 years
FlesidentA
- Uncontrolled 1 year 9 years 5 years
Y Standard or controled** 1 year % 5 years 8 years
aCornmer; Standard al or co *cMed*** 1 Year 3 years 10 years
or -- - -
Uncontrolled 1 year 3 years 3 }_rears
*Combi refers to a combination potable water and space heating application.
Water heaters cannot be used h space heating only applications.
**For units produced on or after Jan. 1, 2016.
***For units produced before Jan. 1.2016-
For complete details please refer to the full warranty at Navieninc.com- -
Operating cost
Navien tankkma
Other tankless 209 Omni $228*
50 gallon tank s�o Mraerns _ $293`
*Based an Energy Guide cost estimates using $1.09 per fhenn of natural gas.
Cost is m US dollars.
Lower HERS home index score
U.S. Green Building Council LEE Points
Water heater L1)catton Recirculation
1 Poml 2 Points 3 Points
m avi l N,
Dimensions Specifications