Loading...
HomeMy WebLinkAbout9616 CROOKED STICK LANE, PSL, FL 34986 PERMIT APPLICATIONAll APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: 11 /11 /2020 Permit Number: 9v" LUME U ° n Building Permit Application Planning and Development Services Building and Code Regulation Division Commercial Residential X 2300 Virginia Avenue, fort Pierce Ft 34982 Phone. (772) 462-1553 Fax: (772) 462-1578 PERMIT APPLICATION FOR:TANKLESS GAS WATER NEATER INSTAL PROPOSED IMPROVEMENT LOCATION: Address: 9616 CROOKED STICK LANE, PORT SAINT LUCIE, FL 34986 Property Tax ID #: 3327-711-0015-000-4 Lot No. 8 Site Plan Name: POD 18 AT THE RESERVE PUD Il (PB 40-16) LOT 8 (OR 4108-2664) Block No. Project Name: Sec/Town/Range: 27/36S/39E DETAILED DESCRIPTION OF WORK: NAVIAN 240-A PROPANE GAS TANKLESS WA I EK HLA i LK INN i Hi_i-H i 1UN New Electrical Meter N/A Second Electrical MeterN/A CONSTRUCTION INFORMATION: Additional work to be performed under this permit— check all that apply: Mechanical ^ Gas Tank —Gas Piping _ Shutters Windows/Doors Pond Electric Plumbing , Sprinklers — Generator Roof Pitch Total Sq. Ft of Construction: Sq. Ft. of First Floor: Cost of Construction: $ 4976.75 Utilities: —Sewer __ Septic Building Height: OWNER/LESSEE: Name DAN FINLEY Address:9616 CROOKED STICK LANE City. PORT SAINT LUCIE State: Zip Code: 34986 Fax:772-871-9069 Phnna Nn_ 772-871-9494 E-Mail: PERMITS u@BENFRANKLINPLUMBER.COM Fill in fee simple Title Holder on next page ( if different from the Owner listed above) CONTRACTOR: Name: MATT BLACK Company:BENJAMIN FRANKLIN PLUMBING Address:6945 NW LTC PARKWAY City: PORT SAINT LUCIE State: FL Zip Code: 34986 Fax: 772-871-9069 Phone No772-871-9494 E-Mail PERMITS@BEN FRANKLINPLUMBER.COM State or County License CFC-1 430437 If value of construction is 2500 or more$ a RECORDED Notice of Commencement is required. If value of HAVC Is $7,500 or more, a RECORDED Notice of Commencement Is required. SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION: DESIGNER/ENGINEER: x Not Applicable Name:_ Address: City: Zip: Phone State FEE SIMPLE TITLE HOLDER: x Not Applicable Name:_ Address: City:_ Zi p: Phone: MORTGAGE COMPANY: x Not Applicable Name:_ Address: City: State: Zip: Phone: BONDING COMPANY: X Not Applicable Name: Address: City: Zip: Phone: OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated. I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in paying twice for improvements to your property. A Notice of Commencement must be recorded in the public records of St. Lucie County and posted on the jobsite before the first inspection. If you intend to obtain financing, consult with lender or an attorney before commencingwork or recording our Notice of Commencement. Signature of Ownel Lessee/Contractor as Agent for Owner Signature of Contractor/License Holder STATE OF FLORIDA STATE OF FLORIDA COUNTY OF S� L[ICJ_C COUNTY OF Swgrn to (or affirmed) and subscribed before me of Swofn to (or affirmed) and subscribed before me of Physical Presence or Online Notarization / Physical Presence or Online Notarization this < < day of AlaL%MhW , 2020 by this _ . day of 1V19V'Gir} 2020 by Name of person making statement. Name of person making statement. Personally Known %/ OR Produced Identification Personally Known _�/ OR Produced Identification Type of Identification Type of Identification Produced Produced (S natur o ry u !E uL (Sign6ftur PNu i f44Mda ) o ry pu is - ate of Florida • Notary public - State of Flo da Commission ! HH 49824 M Comm. Ex Tres Oct 1 20 I) Commissi Commission p HH 49824Se Commissi t ^•�` omm.pires Oct 1, 2424 on ed through National Notary Assn. Bonded through National Notary Assn, - REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE RECEIVED DATE COMPLETED NavieNb N PE Series Condensing Tan kless Water Heaters Navien make it easy to go tankless in residential anc commercial applications N PE -Advanced .�. .�. High -efficiency Button. _ condensing Optional on -demand NPE-A _ tankless recirculation accessory water heaters At the push of a 'i- ,'� y button, the Navien wr f with built-in HotButton hot water recirculation system activates the internal Srecirculation pump and gas system t� th fired burner to heat up e E , 1 UP TO LIP TO water in the supply lines. ®0.971 Q.96i This gives your customers hot water when they need BE$IOElfRCIAL �w we CUMMECIAL It, saving water and money. f � • California Title 24 compliant. •Endless hot water with our dual stainless steel heat exchangers • Up to 80% smaller than tank water heaters •Simpler retrofit with 2" PVC venting *Simpler retrofit with 1/2" gas lines (subject to local code) -one of the industry's strongest warranties -Cascading up to 16 units and common venting up to 8 units -NaviLink'" compatible floW NPE-A internal recirculation system* Navien ComfortFlow is the first system that incorporates a built-in insulated buffer tank and recirculation pump. The buffer tank eliminates the "cold water sandwich" effect commonly found in other tankless water heaters. The +� - recirculation pump saves on your water IS bills by reducing time to get hot water. *When activated, the ComfortFlow modo results in higher energy usage. H2 For combination space heating and domestic hot water An innovative use for the NPE-A's integrated circulator, designed for both retrofit and new construction residontial applications. Navien's HAW' Kit* consists of an add -on controller that allows for space heating and DHW system integration between NPE-A Series tankless water heater models and a hydronic air handler. *Compatible with NPE-A series units produced on or after May 31. 2014. Haviem, NPE-Standard When it comes to water heater performance, it's all about the output The NPE-S condensing tankless water heaters are so efficient that they outperform much larger capacity non -condensing competitors. More output for the money, lower installation costs and lower operating costs for customers makes It a smart choice. Ultra condensing tankless technology with the industry's top energy efficiency rating OOPS "�PF-g RESIOfMTfAL& wwww e" COMMERCIAL *High -efficiency, up to 0.99 EF/0.97 UEF *Endless hot water with our dual stainless steel hea' exchangers • Up to 80% smaller than tank water heaters •Simpler retrofit with 2" PVC venting -Simpler retrofit with 1/2" gas lines (subject to local code) -One of the industry's strongest warranties -Cascading up to 16 units and common venting up to 8 units -NaviLink compatible Navien NPE-5 condensing tankless water heaters outperformed non -condensing comparably priced units OUTPUT.-1131000 BTU/N� -- Non-Contisnsing I Tankless Condensing Tankless Input 199,000 BTU/H } Uniform Energy Factor (UEF) —0.81 0.97 ZIM 1 Output —163,000 - Max GPM 9.8 0 List Price - $$ i=F 1 Installation Time —4-8 Hours 4 Hours j — J p Venting Other type (not PVC)VC - . w v Gas Pipe Typically 3/4' pipe - ... Overall Your Choice? for Ready- U W' Commercial DHW wall or rack modular manifold mounting systems 30 possible configurations Simply build your manifold installation from our easy to install modular kits. Designed to simply save contractors time. -Simply no waiting for factory racks -Simply easy to install ... same day *Simply more profitable Simply visit your local Navien wholesaler and pick up everything you need As simple as 1-2-3-4 1 Pick your Navien Unit, Pick your location, NPE-A or NPE-S wall or rack �- Pick your matching Pick your venting manifold kit(s) configuration tj- U L • L. wall Side -by -side in2,3or4 unit modules Rack Side -by -side j in 2, 3 or 4 , unit modules t Rack Back-to-back in2or4 unit modules 4rt W �k �411 NaV1eN- Innovation makes Navien the professional's choice for residential and commercial applications -Building owners and managers appreciate the efficiency, reliability and durability of Navien condensing tankless water heaters over outdated tank systems *Architects and designers appreciate the space saving design and the flexibility in configurations l t F7 A jr • Commercial and residential builders add customer pleasing technology that sets them apart from older, more traditional water heating systems -Contractors can save hours of installation by using economical PVC venting and Navien's Ready -Link commercial domestic hot water manifold system for wall or free standing rack mounted units • Having one of the industry's strongest commercial warranties and customer support gives everyone more peace of mind NaV142N` NPE Series Cascade up to 16 units and common vent up to 8 units With Navien cascading technology, when a unit gets up to 75% capacity the next unit will turn on to help meet requirements and continue until all 16 units are activated. Navien cascading system also balances the workflow of each unit for long life. - Wall penetrations are reduced with Navien's common venting feature. I? UP I116 C' Link. Optional Wi-Fi remote control system NaviL.ink makes it easy to communicate with bnk your Navien systems anywhere internet service is accessible. The Navil_ink module attaches easily to any new or existing* Navien NPE Series tankless water heaters. Once installed, simply download the free app on your smartphone or tablet. Then you will be able to turn your unit on or off, change the water temperature, monitor system status and even activate the recirculation system on your NPE-A tankless water heater with an installed HotButtonr" kit. *Existing installations may require the purchase of a new main PCB and front control panel. Temperature rise ;oM rh M - - am _ Igo mug GPM iiia""s GPM GPM 85 6.8 8.4 10.1 11.2 - 40 5-9 7.4 8.8 9.8 46 6.3 6.5 7.8 8.7 50 4-8 5.9 7.1 7.8 55 4.3 5.3 6.4 7.1 00 4.0 4.9 5.9 6.5 65 3.7 4.5 5.4 6.0 _ 70 3.4 4.2 5.0 5.6 75 3.2 3.9 1 4.7 5.2 8o 3,0 3.7 4.4 4.9 8S 2.8 2.6 -- 2.4 2.2 3.5 3.3 2.9 2.7 4.2 3.9 3.5 3.2 4.6 4.4 3.9 - 3.6 - gp - 100 - 110� 120 2.0 2.5 2.9 1 3.3� 130 1,8 2.3 2.7 3.0 140 1.7 1 2.1 1 2.5 1 2.8 DHW capacity Modals Natural gas (STU/M) Propans Oaa (BTU/H) t NPE-150S 18,000-120,000 18,000-120,000 NPE-1B0 ASS 15,000-1507000 15,00D-150,000 NPE- 110A/S 19900-180,DD0 19,9w-180,000 NPE -240A/S 19,900-199,900 19,900-199,900 Warranty Appiiostion Recirculation Labor Parts Haut - - Staridard or controlled 1 yew 5 years 15 years FlesidentA - Uncontrolled 1 year 9 years 5 years Y Standard or controled** 1 year % 5 years 8 years aCornmer; Standard al or co *cMed*** 1 Year 3 years 10 years or -- - - Uncontrolled 1 year 3 years 3 }_rears *Combi refers to a combination potable water and space heating application. Water heaters cannot be used h space heating only applications. **For units produced on or after Jan. 1, 2016. ***For units produced before Jan. 1.2016- For complete details please refer to the full warranty at Navieninc.com- - Operating cost Navien tankkma Other tankless 209 Omni $228* 50 gallon tank s�o Mraerns _ $293` *Based an Energy Guide cost estimates using $1.09 per fhenn of natural gas. Cost is m US dollars. Lower HERS home index score U.S. Green Building Council LEE Points Water heater L1)catton Recirculation 1 Poml 2 Points 3 Points m avi l N, Dimensions Specifications