Loading...
HomeMy WebLinkAboutO'QUINN- ENERGY CALC signedEnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 710/15/2020 10:09 AM Project Name: Owner: Builder Name: Permit Office: Jurisdiction: ST LUCIE COUNTY ST LUCIE COUNTY TREFELNER CONSTRUCTION LINDA O'QUINN O'QUINN RESIDENCE Street: City, State, Zip: FORT PIERCE , FL , 34951 SOUTHWIND TRAIL Permit Number: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft²) New (From Plans) Single-family 1 No 1941 7. Windows a. U-Factor: S H G C : b. U-Factor: S H G C : c. U-Factor: S H G C : d. U-Factor: S H G C : Sgl, U=0.32 344.00 ft² SHGC=0.22 Sgl, U=0.29 24.00 ft² SHGC=0.23 N/A f t ² N/A f t ² 8. Floor Types a. Slab-On-Grade Edge Insulation b. N/A c. N/A R=0.0 1941.00 ft² R=f t ² R=f t ² 9. Wall Types a. Concrete Block - Int Insul, Exterior R=4.1 1728.00 ft² b. Frame - Wood, Adjacent R=11.0 470.00 ft² c. N/A R=f t ² 10. Ceiling Types a. Roof Deck (Unvented)R=20.0 1941.00 ft² f t ² R=b. N/A c. N/A R = f t ² 11. Ducts a. Sup: Attic, Ret: Attic, AH: Garage 12. Cooling systems 13. Heating systems 14. Hot water systems a. Electric Cap: 50 gallons b. Conservation features None d. N/A R=f t ² Area Weighted Average Overhang Depth:9.326 ft. Area Weighted Average SHGC:0.221 Description Area Insulation Area Insulation Area Insulation Area 15. Credits None 2 (368.0 sqft.) (2198.0 sqft.) (1941.0 sqft.) (1941.0 sqft.) Conditioned floor area below grade (ft²) 0 a. Central Unit a. Electric Strip Heat k B t u / h r 35.2 SEER:16.00 Efficiency k B t u / h r Efficiency 27.0 COP:1.00 f t ² R 6 150 EF: 0.980 Glass/Floor Area: 0.190 Total Proposed Modified Loads: Total Baseline Loads: 66.55 67.17 PASS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: BUILDING OFFICIAL: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method FORM R405-2017 10-15-2020 PROJECT Title: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: ST LUCIE COUNTY ST LUCIE COUNTY TREFELNER CONSTRUCTI 1 LINDA O'QUINN O'QUINN RESIDENCE Family Type: New/Existing: Bedrooms: Conditioned Area: Total Stories: Worst Case: Rotate Angle:0 No 1 1941 2 New (From Plans) Single-family Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: FL , 34951 FORT PIERCE , St. Lucie SOUTHWIND TRAIL Street Address Comment: Building Type: User Cross Ventilation:No Whole House Fan:No TMY Site Design Temp Int Design Temp Heating Design Daily Temp Design Location 2.5 %97.5 %Degree Days Moisture RangeWinter Summer CLIMATE 90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______ Number Name Area Volume BLOCKS 1 Entire House 1941 20146 Number Name Area Volume SPACES Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished 1 TOILET RM 34 340 No 0 Yes Yes1 Yes 2 LAUNDRY RM 102 1020 No 0 Yes Yes1 Yes 3 PANTRY 30 300 No 0 Yes Yes1 No 4 ENTRY WAY 28 280 No 0 Yes Yes1 No 5 KITCHEN/DINING 273 2730 Yes 0 Yes Yes1 Yes 6 BATH 2 60 600 No 0 Yes Yes1 No 7 LINEN 6 60 No 0 Yes Yes1 No 8 HALL 12 120 No 0 Yes Yes1 No 9 BEDROOM 2 156 1560 No 0 1 Yes Yes1 Yes 10 CLST 2 14 140 No 0 Yes Yes1 Yes 11 FOYER 66 660 No 0 Yes Yes1 Yes 12 STUDY CLST 14 140 No 0 Yes Yes1 Yes 13 STUDY 156 1560 No 0 Yes Yes1 Yes 14 GREAT RM 450 4950 No 0 Yes Yes1 Yes 15 M BATH 143 1430 No 0 Yes Yes1 Yes 16 M TOILET 28 280 No 0 Yes Yes1 Yes 17 M WIC 83 830 No 0 Yes Yes1 No 18 MASTER BEDROO 286 3146 No 0 1 Yes Yes1 Yes 10/15/2020 10:09 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpace Perimeter 1 34 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -013 ft TOILET RM 2 102 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -010 ft LAUNDRY RM 3 30 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft PANTRY 4 28 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft ENTRY WAY 5 273 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -010 ft KITCHEN/DININ 6 60 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft BATH 2 7 6 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft LINEN 8 12 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft HALL 9 156 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -019 ft BEDROOM 2 10 14 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -07 ft CLST 2 11 66 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -09 ft FOYER 12 14 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -07 ft STUDY CLST 13 156 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -025 ft STUDY 14 450 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -015 ft GREAT RM 15 143 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -016 ft M BATH 16 28 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -04 ft M TOILET 17 83 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft M WIC 18 286 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -033 ft MASTER BEDRO # Type Materials Color Absor. Roof Solar Deck Insul. Pitch ROOF Tested Roof Area Gable Area Emitt Tested EmittSA (deg) Rad Barr 1 Hip Metal 2102 ft² Light 0.3 20 22.6______No0 ft² 0.9 NoN ATTIC # Type Ventilation Area RBS IRCCVent Ratio (1 in) ______ 1 Full attic Unvented 1941 ft² N N0 10/15/2020 10:09 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # Ceiling Type R-Value Area Framing Frac Truss Type CEILING Space Ins Type 1 Under Attic (Unvented)0 34 ft² 0.1 Wood______TOILET RM Blown 2 Under Attic (Unvented)0 102 ft² 0.1 Wood______LAUNDRY RM Blown 3 Under Attic (Unvented)0 30 ft² 0.1 Wood______PANTRY Blown 4 Under Attic (Unvented)0 28 ft² 0.1 Wood______ENTRY WAY Blown 5 Under Attic (Unvented)0 273 ft² 0.1 Wood______KITCHEN/DININ Blown 6 Under Attic (Unvented)0 60 ft² 0.1 Wood______BATH 2 Blown 7 Under Attic (Unvented)0 6 ft² 0.1 Wood______LINEN Blown 8 Under Attic (Unvented)0 12 ft² 0.1 Wood______HALL Blown 9 Under Attic (Unvented)0 156 ft² 0.1 Wood______BEDROOM 2 Blown 10 Under Attic (Unvented)0 14 ft² 0.1 Wood______CLST 2 Blown 11 Under Attic (Unvented)0 66 ft² 0.1 Wood______FOYER Blown 12 Under Attic (Unvented)0 14 ft² 0.1 Wood______STUDY CLST Blown 13 Under Attic (Unvented)0 156 ft² 0.1 Wood______STUDY Blown 14 Under Attic (Unvented)0 450 ft² 0.1 Wood______GREAT RM Blown 15 Under Attic (Unvented)0 143 ft² 0.1 Wood______M BATH Blown 16 Under Attic (Unvented)0 28 ft² 0.1 Wood______M TOILET Blown 17 Under Attic (Unvented)0 83 ft² 0.1 Wood______M WIC Blown 18 Under Attic (Unvented)0 286 ft² 0.1 Wood______MASTER BEDRO Blown WALLS #Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 1 4.1 0TOILET RM 0007 10N Concrete Block - Int Insul 0.30Exterior70.0 ft² ____ 2 4.1 0TOILET RM 0006 10E Concrete Block - Int Insul 0.30Exterior60.0 ft² ____ 3 11 0TOILET RM 0004 10W Frame - Wood 0.30.1Garage40.0 ft² ____ 4 4.1 0LAUNDRY R 00010 10E Concrete Block - Int Insul 0.30Exterior100.0 ft² ____ 5 11 0LAUNDRY R 0002 10N Frame - Wood 0.30.1Garage20.0 ft² ____ 6 11 0PANTRY0005 10W Frame - Wood 0.30.1Garage50.0 ft² ____ 7 11 0PANTRY0002 10S Frame - Wood 0.30.1Garage20.0 ft² ____ 8 11 0PANTRY0006 10N Frame - Wood 0.30.1Garage60.0 ft² ____ 9 11 0ENTRY WAY 0004 10W Frame - Wood 0.30.1Garage40.0 ft² ____ 10 4.1 0KITCHEN/DI 00010 10E Concrete Block - Int Insul 0.30Exterior100.0 ft² ____ 11 11 0KITCHEN/DI 00011 10N Frame - Wood 0.30.1Garage110.0 ft² ____ 12 11 0BATH 2 0006 10N Frame - Wood 0.30.1Garage60.0 ft² ____ 13 4.1 0BEDROOM 2 0005 10N Concrete Block - Int Insul 0.30Exterior50.0 ft² ____ 14 4.1 0BEDROOM 2 00014 10W Concrete Block - Int Insul 0.30Exterior140.0 ft² ____ 15 11 0BEDROOM 2 0007 10N Frame - Wood 0.30.1Garage70.0 ft² ____ 16 4.1 0CLST 2 0005 10S Concrete Block - Int Insul 0.30Exterior50.0 ft² ____ 17 4.1 0CLST 2 0002 10W Concrete Block - Int Insul 0.30Exterior20.0 ft² ____ 18 4.1 0FOYER0009 10W Concrete Block - Int Insul 0.30Exterior90.0 ft² ____ 19 4.1 0STUDY CLST 0005 10N Concrete Block - Int Insul 0.30Exterior50.0 ft² ____ 20 4.1 0STUDY CLST 0002 10W Concrete Block - Int Insul 0.30Exterior20.0 ft² ____ 21 4.1 0STUDY00011 10S Concrete Block - Int Insul 0.30Exterior110.0 ft² ____ 22 4.1 0STUDY00014 10W Concrete Block - Int Insul 0.30Exterior140.0 ft² ____ 10/15/2020 10:09 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS #Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 23 4.1 0GREAT RM 00015 11E Concrete Block - Int Insul 0.30Exterior165.0 ft² ____ 24 4.1 0M BATH 00011 10S Concrete Block - Int Insul 0.30Exterior110.0 ft² ____ 25 4.1 0M BATH 0005 10W Concrete Block - Int Insul 0.30Exterior50.0 ft² ____ 26 4.1 0M TOILET 0004 10S Concrete Block - Int Insul 0.30Exterior40.0 ft² ____ 27 4.1 0MASTER BE 00018 11E Concrete Block - Int Insul 0.30Exterior198.0 ft² ____ 28 4.1 0MASTER BE 00015 11S Concrete Block - Int Insul 0.30Exterior165.0 ft² ____ #Door Type U-Value AreaStorms DOORS Ornt Space Width Ft In Ft In Height 1 Insulated .23 21.3 ft² None______W ENTRY WAY 882 # Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening WINDOWS Overhang Orientation shown is the entered, Proposed orientation. Wall ID Imp 1 E Low-E Single 0.32 0.22 20.0 ft² 1 ft 6 in 1 ft 4 in NoneVinyl None______Yes2 Y 2 E Low-E Single 0.29 0.23 12.0 ft² 1 ft 6 in 1 ft 4 in NoneVinyl None______Yes4 Y 3 E Low-E Single 0.32 0.22 48.0 ft² 11 ft 6 in 1 ft 4 in NoneVinyl None______Yes10 Y 4 W Low-E Single 0.32 0.22 36.0 ft² 7 ft 6 in 1 ft 4 in NoneVinyl None______Yes14 Y 5 W Low-E Single 0.32 0.22 48.0 ft² 12 ft 6 in 1 ft 4 in NoneVinyl None______Yes18 Y 6 W Low-E Single 0.32 0.22 36.0 ft² 7 ft 6 in 1 ft 4 in NoneVinyl None______Yes22 Y 7 E Low-E Single 0.32 0.22 48.0 ft² 11 ft 6 in 1 ft 4 in NoneVinyl None______Yes23 Y 8 E Low-E Single 0.32 0.22 48.0 ft² 11 ft 6 in 1 ft 4 in NoneVinyl None______Yes23 Y 9 S Low-E Single 0.29 0.23 8.0 ft² 1 ft 6 in 1 ft 4 in NoneVinyl None______Yes24 Y 10 E Low-E Single 0.32 0.22 48.0 ft² 11 ft 6 in 1 f t 4 in NoneVinyl None______Yes27 Y 11 S Low-E Single 0.32 0.22 12.0 ft² 1 ft 6 in 1 ft 4 in NoneVinyl None______Yes28 Y 12 W Low-E Single 0.29 0.23 4.0 ft² 1 ft 6 in 1 ft 4 in NoneVinyl None______Yes25 Y # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation GARAGE 1 660 ft² 660 ft² 47 ft 10 ft 11______ Method CFM 50 ACH 50ELASLAScope INFILTRATION ACHEqLA# 2350.4 7129.03.000462Wholehouse .1775242.66Proposed ACH(50)1 10/15/2020 10:09 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Efficiency Capacity DuctsSubtypeBlockSpeed 1 Electric Strip Heat/COP:1 27 kBtu/hr ______sys#1None1 # System Type Efficiency Capacity Air Flow SHR COOLING SYSTEM DuctsSubtypeBlockSubtype 1 Central Unit/SEER: 16 35.2 kBtu/hr 1056 cfm 0.8______sys#1Split1 Single # System Type EF Cap Use SetPnt Conservation HOT WATER SYSTEM SubType Location 1 Electric 0.98 50 gal 62.3 gal 120 deg None______None Garage FSEC Company Name System Model #Collector Model # Collector SOLAR HOT WATER SYSTEM Storage FEFCert #Area Volume None None f t ² ______ # Location R-Value Area Location Area ---- Supply -------- Return ---- Leakage Type Handler CFM 25Air QN RLF DUCTS Heat Cool HVAC # TOT OUT CFM25 1 Attic 6 150 ft² Attic 15 ft² Default Leakage Garage (Default) c______1 1 (Default) c TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec [ ] Dec [X] Dec[X] Nov [X] Nov [ ] Oct [X] Oct [ ] Sep [ ] Sep [ ] Aug [ ] Aug [ ] Jul [ ] Jul[ ] Jun [ ] Jun [X] Jun [ ] May [ ] May [ ] Apr [X] Apr [X] Mar [X] Mar [X] Feb [ ] Feb [X] Jan [ ] Jan Heating Venting Thermostat Schedule:HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD)AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Cooling (WEH)AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Heating (WD)AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH)AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 TOILET RM Default(8 lbs/sq.ft.f t ² f t 0.3 LAUNDRY RM Default(8 lbs/sq.ft.f t ² f t 0.3 PANTRY Default(8 lbs/sq.ft.f t ² f t 0.3 ENTRY WAY Default(8 lbs/sq.ft.f t ² f t 0.3 KITCHEN/DINING Default(8 lbs/sq.ft.f t ² f t 0.3 BATH 2 Default(8 lbs/sq.ft.f t ² f t 0.3 LINEN Default(8 lbs/sq.ft.f t ² f t 0.3 HALL 10/15/2020 10:09 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 2 Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 2 Default(8 lbs/sq.ft.f t ² f t 0.3 FOYER Default(8 lbs/sq.ft.f t ² f t 0.3 STUDY CLST Default(8 lbs/sq.ft.f t ² f t 0.3 STUDY Default(8 lbs/sq.ft.f t ² f t 0.3 GREAT RM Default(8 lbs/sq.ft.f t ² f t 0.3 M BATH Default(8 lbs/sq.ft.f t ² f t 0.3 M TOILET Default(8 lbs/sq.ft.f t ² f t 0.3 M WIC Default(8 lbs/sq.ft.f t ² f t 0.3 MASTER BEDROO 10/15/2020 10:09 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT ��������������������������������������������������������������������������� ��������������������������������������������������������������������������������� �����������������������������������������������������