Loading...
HomeMy WebLinkAboutO'Quinn signed print A-6Smoke detectors wired to 120V Bathroom lights Non Switchable, Non GFI Electrical contractor to verify all equipment loads prior to start of construction. Electrical contractor to recalculate electrical schedule if loads are to be modified Electrical Notes 1. All loads to be checked by a Florida Licensed Electrician 2. All work to meet the National Electrical Code 3. Calculations and panels below are for sizing conduit and overall building load requirements only 4. All conductors to be copper; all insulation to be THHN. Conduit as follows: PVC below ground, Rigid from underground to service box for exterior lights on building; AC, MC, or EMT conduit elsewhere. 5. Ensure min. 36" clear between equipment and disconnects, Typical. Electrical Load Calculations 1941 Living S.F. at 3 VA 5823 watts One 20 Amp Appliance Ckts. 1500 watts Two Laundry Cir. @ 1500 watts 3000 watts One Dishwasher & One Disposal @ 1500 watts each 3000 watts One Microwave @ 2000 watts 2000 watts One Wall Oven 6000 watts One Dryer @ 5 kw 5000 watts One Ref. @ 1500 watts 1500 watts Three Baths @ 1500 watts each 4500 watts One Exhaust Hood 1000 watts Water Heater 8500 watts Septic Hook Up 1200 watts Well Pump 1400 watts Total 5/8" dia. x 10'-0" long ground rod " 44,423 watts First 10 KVA at 100% 10,000 watts Remainder at 40% 13,769 watts Total 23,769 watts One AC Heat at 100% 10,000 watts Total 33,769 watts 33,769 W / 240 V = 140.7 Amps Use 200A Service (3) #2/0 (THW) copper and (1) #4 ground (THW) copper in 2" gals. conduit Panel: 200 A.M.C.B. ( 200 Amp 1,6, 3W 40 Circuit Panel 120/240 Volt a.c. disc. 3/4" copper water pipe -i n (3) (3) #2/0 (THW) copper and (1) #4 ground (THW) copper in 2 gals. conduit Wall F.P.L. service `(if overhead / service) (3) #2/0 (THW) copper and (1) #4 ground (THW) copper in 2 galy. conduit F.P.L. service (if underground service) tie ground wire to footing rebars Electrical Riser Diagram wp Meter 0 F3, Electrical Plan scale: 1/4 = I -u "b w I=1 l=r'_TDTr'_el l r:nnl~nin RECESSED LIGHT WITH LENS @ EXTERIOR & WET LOCATIONS SURFACE MOUNTED LIGHT FIXTURE SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE UNDER CABINET FLUORESCENT FIXTURE RECESSED INCANDESCENT LIGHT FIXTURE WITH EXHAUST FAN CEILING FAN EXHAUST FAN OUTLET THERMOSTAT DUPLEX OUTLET - SWITCHED DUPLEX OUTLET 220 V OUTLET SWITCH THREE WAY SWITCH DOOR CHIMES SD COMBO SMOKE & CARBON MONOXIDE DETECTOR -f+ TELEVISION -Q TELEPHONE I] PUSH BUTTON -rfr DIMMER SWITCH D NOTE: RECEPTACLES IN KITCHEN & BATH AREAS TO BE 46"" A.F.F. ALL 120V SINGLE PHASE 15 & 20 AMP BRANCH CIRCUITS SUPPLYING OUTLETS THAT ARE NOT GFCI MUST BE AFCI. TAMPER PROOF RECEPTICALES MUST BE INSTALLED IN 120 VOLT, SINGLE PHASE 15 & 20 AMP BRANCH CIRCUITS COORDINATE THE TV AND PHONE LOCATIONS WITH CONTRACTOR V Q C: ~ > �_ Q. UJ Q r— v � CV -t CV O L 0� W 00 oro R �.J z M C%J C' "' LL L0 c0 b.0 ' UJ U i. Ctt noo 0 U 0- LA J 0000 ® --1 L1 N Q® I— � ~11 WL- U U > U r ® _ (� Lf LU M 4-J VJ CU Q ~ > �_ CU UJ Q r— v i --Ln rn - . � -t CV . LL = U o ® z oro C%J va (,� W r cu N 00 noo CY)T1— J +z Q LL �_ � aL tl! �� O v LL Z w >� LI1 O O va (,� U W N �_ J I— U) Z) U drawn s.l. checked $1 date 11/7/2020 scale as rioted job number 20011 sheet A-6