HomeMy WebLinkAboutAnchors - Miami Dade EACH 2'-0" BLOCK MUST BE
INSTALLED WITH (2) ROWS
OF 10d NAILS @ 3" O.C.
O
z ATTACH BRACKET TO STUD
o STUD THRU HOLE IN
Lu
ANCHOR PLATE WITH
O 3/8"0 x 6" CARRIAGE to
BOLT AND LOCKNUT
CORNER STUD STUD
SIDING
END WALL TRIM
ANCHOR BRACKET
TO BE FLUSH WITH
EDGE OF TRIM
0
Co BUILDING SIZE QTY OF ANCHORS
UP TO 8X12 4
UP TO 10X15 4
N ANCHORS INSTALLED AT EACH
CORNER OF THE BUILDING
AUGER ANCHO Y OLIVER TECHNOLOGIES
• PART NUMBERS:
OT3644GPMP- 5/8" X 36" (36" IMBED) GALVANIZED AUGER
OT17SWB - SIDEWALL BRACKET FOR USE WITH THRU BOLTS
REPORT NO. LO-FJ90129-A '
-OR-
OT24SWBSIDEWALL BRACKET FOR USE WITH THRU BOLTS
REPORT NO. LO-FJ90129-B
• WORKING LOAD FOR ANCHOR SYSTEM 1S 3,150 LBS
WITH THE MAXIMUM LOAD OF 5,080 LBS
• THE ANCHORS MUST BE INSTALLED AND TESTED IN
ACCORDANCE TO THE MANUFACTURER'S SPECIFICATIONS. • W/�����i/
N 6835
2017 FLORIDA BUILDING CODE, 6TH EDITION, HVHZ ° '•• FcAr�
xx F ,R,�
SS�OlVA t �Nc�
Scale: NTS CUSTOMERS NAME: Tuff Shed P.O.#: / 1;1lllflfll�����
TUFF SHED' Title:AUGER ANCHOR DETAIL Drawn By:PK
SWr"o Buk&W d A ee FOR WIND SPEEDS Date Drawn:3/13/19
Checked By:
UP TO 175 MPH Date Revised: