HomeMy WebLinkAboutAnchors - Miami Dade EACH 2'-0" BLOCK MUST BE INSTALLED WITH (2) ROWS OF 10d NAILS @ 3" O.C. O z ATTACH BRACKET TO STUD o STUD THRU HOLE IN Lu ANCHOR PLATE WITH O 3/8"0 x 6" CARRIAGE to BOLT AND LOCKNUT CORNER STUD STUD SIDING END WALL TRIM ANCHOR BRACKET TO BE FLUSH WITH EDGE OF TRIM 0 Co BUILDING SIZE QTY OF ANCHORS UP TO 8X12 4 UP TO 10X15 4 N ANCHORS INSTALLED AT EACH CORNER OF THE BUILDING AUGER ANCHO Y OLIVER TECHNOLOGIES • PART NUMBERS: OT3644GPMP- 5/8" X 36" (36" IMBED) GALVANIZED AUGER OT17SWB - SIDEWALL BRACKET FOR USE WITH THRU BOLTS REPORT NO. LO-FJ90129-A ' -OR- OT24SWBSIDEWALL BRACKET FOR USE WITH THRU BOLTS REPORT NO. LO-FJ90129-B • WORKING LOAD FOR ANCHOR SYSTEM 1S 3,150 LBS WITH THE MAXIMUM LOAD OF 5,080 LBS • THE ANCHORS MUST BE INSTALLED AND TESTED IN ACCORDANCE TO THE MANUFACTURER'S SPECIFICATIONS. • W/�����i/ N 6835 2017 FLORIDA BUILDING CODE, 6TH EDITION, HVHZ ° '•• FcAr� xx F ,R,� SS�OlVA t �Nc� Scale: NTS CUSTOMERS NAME: Tuff Shed P.O.#: / 1;1lllflfll����� TUFF SHED' Title:AUGER ANCHOR DETAIL Drawn By:PK SWr"o Buk&W d A ee FOR WIND SPEEDS Date Drawn:3/13/19 Checked By: UP TO 175 MPH Date Revised: