HomeMy WebLinkAboutGadway wellDETAIL ELECTRICIAN ES12001430
service@detailelectrician.com
Permit Address: Gadway - 102 Springhill Dr, Jensen Beach 34957
Existing well pump being relocated closer to well head.
WELL PUMP WIRING:
1) Add 30A DP breaker to meter main panel at rear of dwelling.
2) Run #10 THHN through ½” Sch 80 conduit from rear of dwelling to
front corner. Surface mounted.
3) Install 60A disconnect.
4) #10 THHN through underground Sch 80 PVC from disconnect to
pump area. Trenched to 18”.
60A
disconnect
(4) #10
THHN
through ½”
S80 PVC
conduit
30A
breaker
Meter Main
Panel
Stub out for
well pump
#10 THHN in
Sch 80 1/2”
PVC
underground