Loading...
HomeMy WebLinkAboutGadway wellDETAIL ELECTRICIAN ES12001430 service@detailelectrician.com Permit Address: Gadway - 102 Springhill Dr, Jensen Beach 34957 Existing well pump being relocated closer to well head. WELL PUMP WIRING: 1) Add 30A DP breaker to meter main panel at rear of dwelling. 2) Run #10 THHN through ½” Sch 80 conduit from rear of dwelling to front corner. Surface mounted. 3) Install 60A disconnect. 4) #10 THHN through underground Sch 80 PVC from disconnect to pump area. Trenched to 18”. 60A disconnect (4) #10 THHN through ½” S80 PVC conduit 30A breaker Meter Main Panel Stub out for well pump #10 THHN in Sch 80 1/2” PVC underground