HomeMy WebLinkAbout200098-4d Compaction signedHeadquarters
11345 U.S. Highway 1
Sebastian, FL. 32958
Orlando
723 Progress Way
Sanford, FL. 32771
Mailing
PO Box 78-1377
Sebastian, FL. 32978
Phone: 772-589-0712
C.A.# 5693
KSMengineering.net
November 13, 2020 KSM JOB # :200098-4d/CH/ct
CONTRACTOR:B & D Grading and Land Clearing
P. O. Box 13437
Fort Pierce, FL 34979
JOB LOCATION:8347 Calumet Court
Port St Lucie, Florida
PERMIT #:
To Whom it may concern,
Should you have any question, please feel free to contact our office.
Respectfully,
Julie E. Keller, P.E.
President
PE # 68366 11/13/20
Email to: bdgrading@att.net
Proudly Serving Florida since 1990
Enclosed, please find the nuclear density test results performed on the stemwall backfill at the above referenced
project.
Headquarters
11345 U.S. Highway 1
Sebastian, FL. 32958
Orlando
723 Progress Way
Sanford, FL. 32771
Mailing
PO Box 78-1377
Sebastian, FL. 32978
Phone: 772-589-0712
C.A.# 5693
KSMengineering.net
DATE TESTED:KSM JOB # :200098-4d/CH/ct
PERMIT #:NUC #417
CONTRACTOR:B & D Grading and Land Clearing Nuc Model:3500
JOB LOCATION:8347 Calumet Court Nuc Serial #:3417
Port St Lucie, Florida
ITEM TESTED:Stemwall Backfill
TEST LOCATION
OF SAMPLE DEPTH PEN
READ
DRY
DENSITY
MAX. DRY
PROCTOR VALUE (P.C.F.)
PERCENT
COMPACTION
1. S.E.0" - 12"45 110.7 111.2 99.6%
2. S.W."45 111.0 "99.8%
3. Center "40 109.0 "98.0%
4. N.E."45 110.2 "99.1%
5. N.W."45 110.8 "99.6%
Soil Description:
Brown Sand with
Some Clay
In Place Moisture:
12.4%
Proctor Optimum Moisture:
11.0%
Proctor Max. Dry Density: P.C.F.
111.2
@ Test Locations the Density &
Penetrometer reading indicate the
Degree of Compaction Meets
Minimum Requirement
for Staked Foundation
Julie E. Keller, P.E.
President
PE # 68366 11/13/2020
Proudly Serving Florida since 1990
Disclaimer:Contractor is responsible to maintain
the tested area in the condition that KSM
completed the indicated passed compaction test.
KSM is not responsible if the tested area has been
altered from the approved inspected condition.
SOIL COMPACTION REPORT
ASTM D 1557 and ASTM D 6938
November 12, 2020
Headquarters
11345 U.S. Highway 1
Sebastian, FL. 32958
Orlando
723 Progress Way
Sanford, FL. 32771
Mailing
PO Box 78-1377
Sebastian, FL. 32978
Phone: 772-589-0712
C.A.# 5693
KSMengineering.net
DATE TESTED:KSM JOB # :200098-4d/CH/ct
PERMIT #:
CONTRACTOR:B & D Grading and Land Clearing
JOB LOCATION:8347 Calumet Court
Port St Lucie, Florida
Soil Description:
Brown Sand with
Some Clay
Proctor Optimum Moisture:
11.0%
Proctor Max. Dry Density: P.C.F.
111.2
Julie E. Keller, P.E.
President
PE # 68366 11/13/2020
SOIL COMPACTION REPORT
ASTM D 1557
November 12, 2020
Proudly Serving Florida since 1990
106.0
107.0
108.0
109.0
110.0
111.0
112.0
6 7 8 9 10 11 12 13 14
W
E
I
G
H
T
P
.
C
.
F
.
D
R
Y
Moisture -% of Dry Weight