Loading...
HomeMy WebLinkAboutInspection Card0 Ste% . aec� �e%c�a1 V Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1148 http://stlucleco.gov/ce INSPECTION CARD Permit M SLC- 0709-0074 Conf M 640 Type: Building Residential (SFR) Issued 11/30/2007 Status: FIN Double Fee: No Job Location 5212 MANCIANO ST City: FORT PIERCE Jurisdiction: St. Lucie County Lot: 4 Block: 4 Parcel: 1311-700-0207-000/8 Subdiv: Waterstone Phase One Flood: X Elev: Flood Map: 70F Job Description: NEW CONSTRUCTION OF SINGLE FAMILY TOWNHOUSE 3 BEDROOM 2.5 BATHROOMS Setbacks Left: 0.00 Right 4.00 Front 25.00 Rear, 28.00 Inspection Notes: 4114/08 co pending solid waste and fire dept final. (vw) bac Contractor ROBERT G. INTILLE MARONDA HOMES INC OF FLORIDA (321) 725-5645 4610 LIPSCOMB ST NE STE # 1 PALM BAY, FL 32905 Property Owner MARONDA HOMES, INC OF FLORID, (321) 725-5645 202 PARK WEST DRIVE PITTSBURGH, PA 15275 SUB -PERMITS Permit # Status PT Cert # DBA Owner / Builder Job Description 0709-0074-01 FIN EP 24777 MARONDA HOMES INC OF FI 0709-0074-02 FIN PP 24778 MARONDA HOMES INC OF FI 0709-0074-03 FIN ME 24779 MARONDA HOMES INC OF FI 0709-0074-04 FIN RP 10170 WILCO CONSTRUCTION INC INSPECTIONS - For Requests, Call: (772) 462-1261 Permit # Code Description Priority Date Sched. Res Description 0709-0074 425 Sewer Connect 0 03/18/2008 90 Approved null Scheduled: Mon Mar 17 11:22:56 EDT 2008 with value: Tue Mar 18 00:00:00 EDT 2008 Resulted: Tue Mar 18 13:50:57 EDT 2008 0709-0074 900 Plan Revision 0 12/28/2007 90 Approved - contractor provided window attachment details. 0709-0074 104 Compaction Test 1 92 Accepted As Noted 0709-0074 105 Form Board Survey 1 12/17/2007 92 Accepted As Noted 0709-0074 420 Plumbing Rough 1 12/21/2007 90 Approved null - Scheduled: Thu Dec 20 12:27:13 EST 2007 with value: Fri Dec 21 00:00:00 EST 2007 Resulted: Fri Dec 21 14:15:39 EST 2007 0709-0074 427 Temp.Toilet/Temp Culvert 1 12/21/2007 90 Approved null Scheduled: Thu Dec 20 12:27:46 EST 2007 with value: Fri Dec 21 00:00:00 EST 2007 Resulted: Fri Dec 21 14:16:01 EST 2007 0709-0074 103 Eufer Ground 2 12/26/2007 90 Approved null Scheduled: Mon Dec 24 10:34:11 EST 2007 with value: Wed Dec 26 00:00:00 EST 2007 0709-0074 115 Slab 2 12/26/2007 90 Approved null Scheduled: Mon Dec 24 10:35:22 EST 2007 with value: Wed Dec 26 00:00:00 EST 2007 Inspector Date Insp. Greg Smyth 03/18/2008 John Moriarty 12/28/2007 Irvie Saunders 12/17/2007 Ivey Laurie 12/17/2007 Van Whitaker 12/21/2007 Van Whitaker 12/21/2007 Jim Beams Jim Beams 12/26/2007 12/26/2007 Permit Nun 0709-0074 4 0709-0074 121 Termite Spray 2 12/26/2007 90 Approved ~ ' Jim Beams 12/26/2007 null Scheduled: Mon Dec 24 10:34:50 EST 2007 with value: Wed Dec 26 00:00:00 EST 2007 0709-0074 118 Column 3 01/04/2008 81 Disapproved Jim Beams 01/04/2008 0709-0074 118 Column 3 01/08/2008 90 Approved Jim Beams 01/08/2008 Re -inspection 1 0709-0074 128 Bond Beam 3 01/08/2008 90 Approved Jim Beams 01/08/2008 Re -inspection 1 Scheduled: Mon Jan 7 11:46:56 EST 2008 with value: Tue Jan 8 00:00:00 EST 2008 0709-0074 128 Bond Beam 3 01/04/2008 81 Disapproved Jim Beams 01/04/2008 Min. lap on steel is 25" Scheduled: Thu Jan 3 15:43:17 EST 2008 with value: Fri Jan 4 00:00:00 EST 2008 0709-0074 133 Window/Door Bucks 4 02/07/2008 90 Approved Jim Beams 02/07/2008 0709-0074 134 Roof Sheathing 4 02/01/2008 91 Partial Approval Jim Beams 02/01/2008 Need engineers approvel for ripps less than 2 foot wide, Change or block. OK to dry -in will check roof on next trip. Scheduled: Thu Jan 31 13:11:12 EST 2008 with value: Fri Feb 1 00:00:00 EST 2008 0709-0074 134 Roof Sheathing 4 02/07/2008 90 Approved Jim Beams 02/07/2008 Re -inspection 1 0709-0074 137 Strapping 4 02/07/2008 90 Approved Jim Beams 02/07/2008 Re -inspection 1 0709-0074 137 Strapping 4 02/06/2008 75 Cancelled by Custome Jim Beams 02/06/2008 null Scheduled: Tue Feb 5 14:55:11 EST 2008 with value: Wed Feb 6 00:00:00 EST 2008 0709-0074 145 Truss Drwg 4 02/06/2008 75 Cancelled by Custome Jim Beams 02/06/2008 null Scheduled: Tue Feb 5 14:55:49 EST 2008 with value: Wed Feb 6 00:00:00 EST 2008 0709-0074 145 Truss Drwg 4 02/07/2008 90 Approved Jim Beams 02/07/2008 Re -inspection 1 0709-0074 127 Mullion 5 02/12/2008 93 Not Required Jim Beams 02/12/2008 null Scheduled: Mon Feb 11 13:14:54 EST 2008 with value: Tue Feb 12 00:00:00 EST 2008 0709-0074 132 Floor Strapping/Joists 5 02/08/2008 81 Disapproved Jim Beams 02/08/2008 Missing straps on outside walls. Scheduled: Thu Feb 7 16:18:34 EST 2008 with value: Fri Feb 8 00:00:00 EST 2008 0709-0074 132 Floor Strapping/Joists 5 02/12/2008 90 Approved Jim Beams 02/12/2008 Re -inspection 1 Scheduled: Mon Feb 11 13:15:24 EST 2008 with value: Tue Feb 12 00:00:00 EST 2008 0709-0074 135 Wall Sheathing 5 02/12/2008 90 Approved Jim Beams 02/12/2008 Re -inspection 1 Scheduled: Mon Feb 11 13:15:55 EST 2008 with value: Tue Feb 12 00:00:00 EST 2008 0709-0074 135 Wall Sheathing 5 02/08/2008 81 Disapproved Jim Beams 02/08/2008 Nailing not per plans. Scheduled: Thu Feb 7 16:19:10 EST 2008 with value: Fri Feb 8 00:00:00 EST 2008 0709-0074 136 Roof Dry-in/Tin Tab 5 02/08/2008 81 Disapproved Jim Beams 02/08/2008 Missing valey metal and drip edge. Scheduled: Thu Feb 7 16:19:42 EST 2008 with value: Fri Feb 8 00:00:00 EST 2008 0709-0074 136 Roof Dry-in/Tin Tab 5 02/12/2008 90 Approved Jim Beams 02/12/2008 Re -inspection 1 Scheduled: Mon Feb 11 13:16:29 EST 2008 with value: Tue Feb 12 00:00:00 EST 2008 0709-0074 140 Construction Rough Frami 5 02/19/2008 90 Approved Dave Johnson 02/19/2008 0709-0074 148 Window/Door Attachment 5 02/12/2008 91 Partial Approval Jim Beams 02/12/2008 Windows and SGD only, no front doors installed. One window left out in each unit upstairs for drywall Scheduled: Mon Feb 11 13:17:03 EST 2008 with value: Tue Feb 12 00:00:00 EST 2008 0709-0074 167 Roof Final 5 02/21/2008 90 Approved Jim Beams 02/21/2008 0709-0074 238 Electric Rough 5 02/19/2008 90 Approved Dave Johnson 02/19/2008 0709-0074 351 Mechanical Rough-In(ducl 5 02/19/2008 90 Approved Dave Johnson 0211912008 Re -inspection 1 0709-0074 423 Plumbing Top Out 5 02/19/2008 81 Disapproved Dave Johnson 02/19/2008 NO TEST ON DWV 0709-0074 423 Plumbing Top Out 5 02/20/2008 90 Approved Dave Johnson 02/20/2008 Re -inspection 1 Scheduled: Tue Feb 19 18:31:45 EST 2008 with value: Wed Feb 20 00:00:00 EST 2008 Permit Nun 0709-0074 0709-0074 600 Product Certification ti_, 5 02/12/2008 91 Partial Approval -' Jim Beams 02/12/2008 For windows only. Scheduled: Mon Feb 11 13:17:35 EST 2008 with value: Tue Feb 12 00:00:00 EST 2008 0709-0074 650 Frame -all 5 02/19/2008 74 Cancelled by Building I Barbara Counsello 02/19/2008 null Scheduled: Mon Feb 18 11:06:38 EST 2008 with value: Tue Feb 19 00:00:00 EST 2008 0709-0074 141 Insulation 6 02/25/2008 90 Approved Scott Attey 02/25/2008 null Resulted: Mon Feb 25 12:49:54 EST 2008 0709-0074 148 Window/Door Attachment 6 03/24/2008 90 Approved Jim Beams 02/12/2008 Re -inspection 1 0709-0074 259 Power Release Form 6 - 92 Accepted As Noted Barbara Counsello 02/21/2008 0709-0074 600 Product Certification 6 03/24/2008 90 Approved Jim Beams 03/24/2008 Re -inspection 1 0709-0074 705 Fire Department Firewall 6 02/21/2008 81 Disapproved Mike Matthy 02/21/2008 2/25/08 RECVD email from linda- mike on 2/21/08 failed inspection. bac 0709-0074 705 Fire Department Firewall 6 02/28/2008 90 Approved Brian Putnam 03/24/2008 Re -inspection 1 0709-0074 153 Insulation Certification 7 92 Accepted As Noted Barbara Counsello 03/26/2008 0709-0074 260 30 Day for Testing 7 03/26/2008 90 Approved Van Whitaker 03/26/2008 email fpl 3/26/08 bac 0709-0074 800 Address Final 7 03/26/2008 90 Approved Van Whitaker 03/26/2008 0709-0074 172 Hurricane Panels (shutter; 8 04/14/2008 90 Approved Van Whitaker 04/14/2008 0709-0074 261 30 Day Expired 8 05/27/2008 92 Accepted As Noted Barbara Counsello 04/17/2008 0709-0074 700 Fire Department Final 8 04/14/2008 90 Approved Brian Putnam 04/14/2008 4/14/08 incall spoke to linda fire dept final approved. bacounsellor 0709-0074 804 Driveway Bldg 8 04/14/2008 90 Approved Van Whitaker 04/14/2008 0709-0074 808 Landscaping/Trees 8 04/14/2008 90 Approved Van Whitaker 04/14/2008 0709-0074 821 Solid Waste 8 92 Accepted As Noted Barbara Counsello 04/17/2008 0709-0074 996 Final Termite Treatment 8 04/14/2008 90 Approved Van Whitaker 04/14/2008 0709-0074 999 Final Inspection 8 99 Final Approval Van Whitaker 04/14/2008 Re -inspection 1 0709-0074 999 Final Inspection 8 04/14/2008 91 Partial Approval Van Whitaker 04/14/2008 Permit Nun 0709-0074