Loading...
HomeMy WebLinkAbout205767-1d Compaction - signedHeadquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net DATE TESTED:KSM JOB #: 205767-1d/CH/jo PERMIT #:NUC #417 CONTRACTOR:Jerry Horton Nuc Model:3500 JOB LOCATION:5000 Southwind Trail Nuc Serial #:3417 Fort Pierce, Florida ITEM TESTED:Metal Building Pad TEST LOCATION OF SAMPLE DEPTH PEN READ DRY DENSITY MAX. DRY PROCTOR VALUE (P.C.F) PERCENT COMPACTION 1. N.W.0" - 12"35+106.4 109.1 97.5% 2. Center "35+106.1 "97.3% 3. S.E."35+105.9 "97.1% Soil Description: Brown Sand with some Shell In Place Moisture: 11.8% Proctor Optimum Moisture: 13.0% Proctor Max. Dry Density: P.C.F. 109.1 @ Test Locations the Density & Penetrometer readings indicate the Degree of Compaction Meets Minimum Requirement for Unstaked Foundation Respectfully Submitted: Bryan E. Dahlke, P.E. V.P. of Engineering PE # 81439 11/16/2020 Email to: St Lucie Building Department; jmhconstruction@me.com Disclaimer:Contractor is responsible to maintain the tested area in the condition that KSM completed the indicated passed compaction test. KSM is not responsible if the tested area has been altered from the approved inspected condition. SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 6938 November 13, 2020 20110063 106.0 107.0 108.0 109.0 110.0 111.0 10 11 12 13 14 15 16 W E I G H T P . C . F . D R Y Moisture -% of Dry Weight Headquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net Proudly Serving Florida since 1990