HomeMy WebLinkAboutBlower Door Test---------------
Planning a Development Services
Building & Code Regulation Division
tj `f a .3 ��._ 2300 Virginia Ave, testa 281
i -ort Pierce, FL 34982
Phone. 772-462-2165 Fax: 772-462-6443
SLOWER DOOR TEST FORM
Mouse 9nfiRrWorn Test CCer dfleation
Prescriptive and Perfoirmmice Me had
Contractor: �A
Job Address: (P� e. c�T2
CMS•_LrUCV0no New Construction — Complete Existing a After Addition
House rrfih-ration'7T `Res h -s SLC Clirnvi*e Zone 2
CFM (50) _ ( Test- Dat -e: it I f 3 2- o
Volume = l Z 00
ACI: (30) = CFM (50) 1160 1 Volur e = �- Mec�'zartical Ventilation regc�%rec! IeSS char, 3 nCh'
Passing results must be & ACH (50) or less (11� Pass ( ) Fail
Me building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through S. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be perormed at any time after creation oil all penetrations ofthe building
thermal envelope. r
F13c, Residendal
Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
Testina Cornoanv
Company Name: Pro -Duct Services
Address: "1915 Rio Vista Drive, Ft. Pierce, FL 3^949
I hereby certirythatthe above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accordance with Section R402.4.1.2 Climate Zone 2.
Signature:
Printed Name: Mein Klein
License/Certification #: 5061633