Loading...
HomeMy WebLinkAboutcompaction Test A R � __� _ Ardaman&Associates.Inc. �� 460 NW Concourse Place,Unit 1 Port St.Lucie,FL 34986 ® Inc. Associates, Poona(772)876-0672 Florida Certificate of Authorization No.00005950 FAX(772)878-0097 MODIFIED PROCTOR (ASTM D-1557) Project Name: Bruce/Mason Date Sampled: 11/12/2020 Project Location: 10301 S.Indian River Dr,Fort Pierce,FL Sampled By: OR File Number: 00-5500 Date Tested: 11/13/2020 Client Name: Mason Construction&Development Tested By: RT 1000.0 Z O Q W a 100.0 .. _ LBR VALUE(%) U. +4 MATERIAL(%) c -4 MATERIAL(%) 10.0 m 1.0 0 1 2 3 4 5 6 7 8 9 10 it 12 13 14 15 16 17 1tt 19 20 MOISTURE CONTENT(%) 120 ®® MAX.DRY "® � DENSITY(pcf) ®e108.0 ®o MOISTURE13.0 (%) f 3 105 PERCENT FINES(%) N/A >-100 _. Curves of 100%Saturation for Specific Gravity Equal t 95 2.60 2.65 90 2.70 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 MOISTURE CONTENT(°k) SAMPLE NUMBER: 20-290 11 1 1 f SAMPLE DESCRIPTION: Gray Fine Sand with Trace Organics ��� 2¢�LL SAMPLE LOCATION: Stockpile � �r1SE PROPOSED USE: Pad Our letters and reports are for th exclusive use of the client to whom they are addressed and stall not be _ 1 LU_ reproduced except in lua without the approval of the testing laboratory.The use of our name must receive our y = written approval.Our letters and reports apply 0*to the sample tested and.or inspected,and are not l` indicative of the quantities of apparently indentical or similar products. Oftr^ Trallll /fltll111�� E- K:] In-Place Density Report Client: Project: *.) UNA3 &ZsoClateS, Inc. Permit#SLC-2009-0417 Mason Construction &Development 113-00-00-5500 Report Date: 11/13/2020 880 Jupiter Park Drive,Suite 10 Bruce/Mason Port St.Lucie Branch Test Method:ASTM D6938 Jupiter, FL 33458 10301 S. Indian River Dr. Florida Registration No.5950 460 NW Concourse Place,unit, Fort Pierce, FL Port St.Lucie,FL 34986 Phone:772-878-0072 In Place In Place Optimum Maximum In Place Dry Wet Probe Retest Test Soil Moisture Dry Density Moisture Density Density Depth Percent Min Comp. Test# Of Date Proctor ID Method Classification N (pcf) (%) (pcf) (pcf) (in) Compaction (°/a) Remark 1 11/12/20 20-290 A - 13.0 108.0 6.9 106.0 113.3 12 98 95 Pass (Modified) 2 11/12/20 20-290 A -- 13.0 108.0 8.4 107.0 116.0 12 99 95 Pass (Modified) 3 11/12/20 20-290 A -- 13.0 108.0 8.1 106.6 115.2 12 99 95 Pass (Modified) 4 11/12/20 20-290 A -- 13.0 108.0 9.2 106.7 116.5 12 99 95 Pass (Modified) 5 11/12/20 20-290 A - 13.0 108.0 8.6 107.2 116.4 12 99 95 Pass Modified 6 11/12/20 20-290 A -- 13.0 108.0 9.8 106.3 116.7 12 98 95 Pass Modified Test Information . Gauge Test# Test Location Elevation Reference Make/Model/SN/Calibrated Field Technician 1 Footings:For Shed Building Pad located at:10301 S Indian River Drive, Fort Pierce. -1.0 Bottom of footings CPN/MC-3/M340507395/ Tech, Port St.Lucie NW End of Footings 2 Footings:For Shed Building Pad located at:10301 S Indian River Drive, Fort Pierce. -1.0 Bottom of footings CPN/MC-3/M340507395/ Tech, Port St.Lucie SW End of Footings 3 Footings:For Shed Building Pad located at:10301 S Indian River Drive, Fort Pierce. -1.0 Bottom of footings CPN/MC-3/M340507395/ Tech, Port St. Lucie NE End of Footings 4 Building Pad Fill:For Shed Building Pad located at:10301 S Indian River Drive, Fort -1.0 Top of pad CPN/MC-3/M340507395/ Tech, Port St.Lucie Pierce. NW End of Pad 5 Building Pad Fill:For Shed Building Pad located at:10301 S Indian River Drive, Fort -1.0 Top of pad CPN/MC-3/M340507395/ Tech, Port St. Lucie Pierce.SW End of Pad 6 Building Pad Fill:For Shed Building Pad located at:10301 S Indian River Drive, Fort -1.0 Top of pad CPN/MC-3/M340507395/ Tech, Port St. Lucie Pierce.SE End of Pad Remarks Comments`, Pass:Density Pass "Gauge calibration (Met Tests are"Diect hod A)unless probe depth is noted as "Backscatter. lion data on file with the testing agency. AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES,ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 1 of 2 THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL. In-Place Density Report Client: Project: 4a &Associates, Inc. Permit#SLC-2009-0417 Mason Construction &Development 113-00-00-5500 Report Date: 11/13/2020 880 Jupiter Park Drive, Suite 10 Bruce/Mason Port St Lucie Branch Test Method:ASTM D6938 Jupiter, FL 33458 10301 S. Indian River Dr. Florida Registration No.5950 460 NW Concourse Place,Unit Fort Pierce, FL Port St.Lucie,FL 34986 Phone:772-878-0072 ��� ` �- J Zi _srAdF This item has been digitally signed and sealed by Branch Manager Dan J.Zrallack, P.E.on Nov 13,2020 using a Digital Signature. Printed copies of this document are not considered signed and sealed and the SHA authentication code must be verified on any electronic copies. AS A MUTUAL PROTECTION TO OUR CLIENT,THE PUBLIC AND OURSELVES,ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 2 of 2 THE CLIENT,AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL.