Loading...
HomeMy WebLinkAboutWind load calcsNewSouth WINDOW SOLUTIONS 2526 Okeechobee Blvd, West Palm Beach, FL 33409 • 561-712-9000 • CRC1330822 PrODertv Information IIII Building Information owner. Carlos, Isabel, & Yean Fernandez Wind Zone: 170 MPH. Address: 180 SE Bonita Ct Exposure Category: C Port St Lucie, FL 34983 Minimum Building Dimension: 25 fL -39.3 Mean Roof Height: 15 & Int Risk Category: 11 40.25 Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width (in) Height (in) Elevation (ft) Pressure (psf) Pressure (psf) I Int 72.75 40.25 7 36.1 -39.3 2 Int 72.75 40.25 7 36.1 -39.3 3 Int 71.50 79.50 7 34.4 -37.6 4 Int 35.75 37.25 7 37.8 -41.0 5 Int 35.75 25.75 7 37.8 41.0 6 Int - 35.75 49.25 - 7- 37.3 40.5 7 Int 35.75 49.25 7 37.3 -40.5 8 Int 35.75 49.25 7 37.3 -40.5 9 Int 35.75 49.25 7 37.3 40.5 10 _ Int 35.75 49.25 7 37.3 -40.5 11 Int _ 109.75 49.25 7 34.5 -37.7 Prepared in accordance wLh: ASCE 7-10, Chaper 30. Wind Loads - Componmu and Gadding. 61h Bdltion (2017) Fl UaBuilding Code. Page 1 of 1