Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED, Design Pressures
Property Information Owner:Stephen Kiss Address:13300 NW Maplewood Road Palm City, FL 34990 Building Information Wind Zone:160 MPH. Exposure Category:C Minimum Building Dimension:50 ft. Mean Roof Height:14 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 End 72 17 7 33.1 -44.0 2 End 37 63 7 32.4 -42.7 3 End 44 63 7 32.1 -42.0 4 End 44 22 7 33.5 -44.8 5 End 44 63 7 32.1 -42.0 6 End 44 22 7 33.5 -44.8 7 End 37 63 7 32.4 -42.7 8 End 37 63 7 32.4 -42.7 Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. 6th Edition (2017) Florida Building Code. Page 1 of 1