HomeMy WebLinkAboutEnergy CodesFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential PeII&Iialr e`�/letho
Project Name: Lot 33 Block 1 Waterstone 2000 AGL
Builder Name: ADAMS HOME 3
-
Street: 8700 Marano Avenue
Permit Office: ST. Lucie County, Permltting
City, State, Zip: Fort Pierce , FL , 34951
Permit Number:
Owner: -
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1941.1 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1428.20 ft2
b. Frame - Wood, Adjacent
R=13.0 288.56 ft2
3. Number of units, if multiple family 1
c. Frame - Wood, Exterior
R=13.0 224.40 ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (2004.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 2004.00 ft2
6. Conditioned floor area above grade (ft2) 2004
b. NIA
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(193.0 sqft.) Description Area
a. Sup: Attic, Ret: Main, AH: Main
6 400.8
a. U-Factor: Dbl, U=0.33 142.83 ft2
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 32.38 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
35.0 SEER:16.00
c. U-Factor: Dbl, U=0.55 17.78 ft2
SHGC: SHGC=0.70
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
34.6 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 4.940 ft.
Area Weighted Average SHGC: 0.270
14. Hot water systems
8. Floor Types (2004.0 sqft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 2004.00 ft2
b. Conservation features
EF: 0.940
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Total Proposed Modified Loads: 60.96
Glass/Floor Area: 0.096
PASS
Total Baseline
Loads: 65.08
I hereby certify that the plans s cations covered b
IZ9714.v of the plans and
1UE S74Z, '
this calculation are in compl' the Florid gy
specifications covered by this
O_
O
Code.
calculation indicates compliance
��
with the Florida Energy Code.
rr�n .'��:, ,','•�:•� °;ti O
PREPARED BY:
Before construction is completed
r
DATE: - -
this building will be inspected for
compliance with Section 553.908
t, y
*,-tv
' o
I hereby certify that this building, as desi ned, is in compliance
Florida Statutes.
with the Florida Et3er o
COD'S
OWNER/AGEN
BUILDING OFFICIAL:
DATE:
DATE:
r - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
t certified factory -sealed in accordance with R403.3.2.1.
...JJJI - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
9/17/2020 11:56 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4
FORM R405-2017 INPUT SUMMARY CHFCKI IST RFPnRT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 33 Block 1 Waterstone 20 Bedrooms: 4
User Conditioned Area: 2004
Total Stories: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Single-family
New (From Plans)
Address Type: . Lot Information
Lot # 33
Block/Subdivision: Waterstone
PlatBook:
Street: 8700 Merano Avenue
County: St. Lucie
City, State, Zip: Fort Pierce ,
FL, 34951
CLIMATE
/
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Blockl
2004 18837.6
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
2004 18837.6 Yes 5
4 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 181.9 ft 0
2004 ft2 ---- 0.35 0 0.65
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Rad Solar SA Emitt Emitt Deck Pitch
Barr Absor. Tested Tested Insul. (deg)
1
Gable or Shed Composition shingles 2241 ft2 502 ft2 Medium
N 0.85 N 0.85 No 0 26.6
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 2004 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
2004 ft2 0.11 Wood
9/17/2020 11:56 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Space Cavity Width
To Wall TvpeR-11alue Et In Ft
Height
In
Are:;
Sheathing Framing Solar Below
R-Vahe Fraction AhSnr Grade%
1 W
Exterior Concrete Block - Int Insul Main
4.1 53 7 9
7
513.5 ft2
0
0 0.6
0
2 S
Exterior Concrete Block - Int Insul Main
4.1 20 0 9
4
186.7 ft2
0
0 0.6
0
3 E
Exterior Frame - Wood Main
13 25 2 8
11
224.4 ft2
0
0.23 0.6
0
4 E
Exterior Concrete Block - Int Insul Main
4.1 39 0 9
4
364.0 ft2
0
0 0.6
0
5 N
Exterior Concrete Block - Int Insul Main
4.1 37 4 9
9
364.0 ft2
0 0.6
0
6 -
Garage Frame - Wood Main
13 30 11 9
4
288.6 ft2
0
0.23 0.01
0
DOORS
#
Ornt Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
- Wood Main
None
.25
2
8
6 8
17.8 ft2
2
S Insulated Main
None
.25
3
6 8
20 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
#
Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screening
1
W 1 Vinyl Low-E Double Yes
0.33 0.23 N
13.3 ft2
1 ft 5 in
0 ft 9 in
None
None
2
W 1 Vinyl Low-E Double Yes
0.33 0.23 N
16.2 ft2
1 ft 5 in
0 ft 9 in
None
None
3
S 2 Vinyl Low-E Double Yes
0.33 0.21 N
32.4 ft2
1 ft 5 in
4 ft 0 in
None
None
4
E 3 Vinyl Low-E Double Yes
0.33 0.23 N
32.4 ft2
1 ft 5 in
0 ft 9 in
None
None
5
N 5 Vinyl Low-E Double Yes
0.55 0.7 N
17.8 ft2
11 ft 8 in
1 ft 0 in
None
None
6
N 5 Vinyl Low-E Double Yes
0.33 0.23 N
32.4 ft2
1 ft 5 in
0 ft 9 in
None
None
7
N 5 Vinyl Low-E Double Yes
0.33 0.23 N
48.6 ft2
11 ft 8 in
0 ft 9 in
Drapes/blinds
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
754 ft2 754 ft2
64 ft
8 ft
1
INFILTRATION
# Scope
Method SLA
CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000418
2197.7 120.65 226.9
.1545
7
HEATING SYSTEM
#
System Type Subtype
Speed Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump/ Split
Singl HSPF:8.5
34.6 kBtu/hr
1
sys#1
9/17/2020 11:56 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
Singl SEER: 16
35 kBtu/hr
1167 cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.94 40 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cart # Company Name
System Model # Collector
Model
# Area
Volume
FEF
None None
ftz
DUCTS
---- Supply ----
---- Return ----
Air
CFM 25 CFM25
HVAC #
# Location R-Value Area
Location
Area Leakage Type
Handler
TOT OUT
QN
RLF
Heat Cool
1 Attic
6 400.8 ft
Main
100.2 ft Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan Feb
HeatinHJan HFeb
Mar
Mar
f
A r
Apr f
Jul
May JunJul
Ma rj Jun rl
Au
AuSep
ri
Se
ri
Oct
Oct
Nov
Nov
HX
Dec
Dec
H
Ventin Jan Feb
X Mar
[
A r [
Ma Jun Jul
Aug
Se [X]
Oct
Nov
Dec
Thermostat Schedule: HERS 2006
Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8 9
10
11
12
Cooling (WD) AM
78
78
78
78 78 78
78
78 80
80
80
80
PM
80
80
78
78 78 78
78
78 78
78
78
78
Cooling (WEH) AM
78
78
78
78 78 78
78
78 78
78
78
78
PM
78
78
78
78 78 78
78
78 78
78
78
78
Heating (WD) AM
66
66
66
66 66 68
68
68 68
68
68
68
PM
68
68
68
68 68 68
68
68 68
68
66
66
Heating (WEH) AM
66
66
66
66 66 68
68
68 68
68
68
68
PM
68
68
68
68 68 68
68
68 68
68
66
66
MASS
Mass Type
Area
Thickness Furniture Fraction Space
Default 8 Ibs/s .ft.
0 ftZ
0 ft
0.3
Main
9/17/2020 11:56 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 94
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Main
3. No. of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 4
13. Cooling. system: Capacity
35.0
a) Split system SEER
16.0
5. Is this a worst case? (yes/no)
5. No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6. 2004
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor: (weighted average)
7a. 0.350
b) Solar Heat Gain Coefficient (SHGC)
7b. 0.270
14. Heating system: Capacity
34.6
c) Area
7c. 193.0
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a. NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b. NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a. 0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.94
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1. 13.0
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2. 4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131. 13.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11 a. 30.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11 c.
d) Multizone cooling credit
d) Radiant barrier installed
11 d. No
e) Multizone heating credit
f) Programmable thermostat
Yes
'Label required by Section R303.1.3 of the Florida
Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the
Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Flo
Builder Signature:
-
Date:
Address of New Home: 8700 Merano Avenue City/FL Zip: Fort Pierce, FL 34951
9/17/2020 11:56:15 AM EnergyGaugeO USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1