Loading...
HomeMy WebLinkAboutwindow door openingA FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET Definition of Corner Zone - 10% of least horizontal dimension or 40% of the mean roof height, whichever is smaller, but not less than 4% of least horizontal dimension or 3 ft OPENING LOCATION NUMBER (Location) Corner Zone or Interior ISTHIS A WINDOW OR DOOR GLAZING TYPE PRODUCT ACCEPTANCE NUMBER PRODUCT APPROVAL APPROVED PRESSURE RATING REQUIRED OPENING DESIGN PRESSURE MAXIMU M TESTED SIZE ROUGH OPENING DIMENSIONS MULTIPLE WINDOW ARE SHUTTERS REQ Y/N (+) PSF (-) PSF (+) PSF (-) PSF MULLION REQY/N/NA I Int Window 77x,`° i16 FL23505.3 60 65 36.5 -39.7 54x'6.5 34x71 No No 2 End Window "x"'°'""° FL15768.9 60 65 37.8 -50.6 48x63 50x25 YES No 3 Int Window TH'"L°"'"° FL23505.3 60 65 35.9 -39.1 54x76.5 1 51x,60 YES No 4 End Window W.'I "'° FL23505.3 60 65 36.4 -47.9 54x76.5 51x49 No No 5 Int 1°indow TV `°""'° FL23505.3 60 65 36.9 -40.1 14 x 761 34x60 No No 6 Int Window "'"`,'i10 FL23505.3 60 65 36.9 -40.1 54x71.5 34x60 No No 7 Int Window 7,8" L^ i10 FL15768.9 60 65 37.8 -41.0 48x63 50x25 YES No 8 Int Window 7W,L"n10 FL23505.3 60 65 36.5 -39.7 54x71.5 50x48 YES No 9 End Window 7'""'°"'"" FL23505.3 60 65 35.9 -46.8 54x71.5 52x60 YES No 10 Int Window 7".' 1,'""° FL23505.3 60 65 35.9 -39.1 54x76.5 52x60 YES No 11 Int Door "'"n"" FL11103.1 60 60 33.0 -36.2 96x96 106x95 No No 12 Int Window 77x`1,'i10 FL23505.3 60 65 37.4 -40.6 54x761 24x71 No No 13 Int Window J78" `"""° FL23505.3 60 65 37.4 -40.6 54 x 76.5 24x71 No No