HomeMy WebLinkAboutProduct Approval (2) SCIS Home [ Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff I BCIS Site Map Links Search
b
' afq:cCa w
2. Product Approval
�, - USER:Public User
L'ka ��f�a ffic>P
Product Acorcvzl Menu>Productor Aoolication Search>Application List>APP liration Detail M -
FL# FL7804-119
Application Type Revision FEB ? 7 2017
Code Version 2014
Application Status A rp I owed_ PERNIITTINIG
St. Lucie Count}, F=L
Comments
Archived 0I
Product Manufacturer Entegra Roof Tile,Inc.
Address/Phone/Email 1289 NE 9th Avenue
Okeechobee,FL 34972
(863)467-0042 Ext 1228
tjohnson@rooftile.com
Authorized Signature Terry Johnson
tjohnson@rooftile.com
Technical Representative Jim Deyarmond
Address/Phone/Email 1289 NE 9th Avenue
Okeechobee,FL 34972
(863)467-0042
JDeyarmond@rooftile.com
Quality Assurance Representative Terry Johnson
Address/Phone/Email 819 South Federal Hwy Suite 300
Stuart,FL 34994
(800)586-7663
tjohnson@rooftile.com
Category Roofing
Subcategory Roofing Tiles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity PRI Construction Materials Technologies,LLC
Quality Assurance Contract Expiration Date 11/04/2017
Validated By John W.Knezevich,PE
!:! Validation Checklist-Hardcopy Received
Certificate of Independence FL7804 R9 COI 2016 01 COI Nieminen.odf
Referenced Standard and Year(of Standard) Standard Year
ASTM C1492 2003
FRSA/TRI April 2012 2012
SSTD 11 1997
TAS 100 1995
TAS 101 1995
TAS 102 1995
TAS 102(A) 1995
TAS 112 1995
,.,,
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 04/19/2016
Date Validated 04/20/2016
Date Pending FBC Approval 04/24/2016
Date Approved 06/08/2016
Summary of Products
FL# Model,Number or Name Description
7804.1 Entegra Concrete Roof Tiles(HVHZ Concrete Roof Tile
jurisdictions)
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL7804 R9 II 2016 04 FINAL ER ENTEGRA FL7804-
Approved for use outside HVHZ:No R9 HVHZ.Ddf
Impact Resistant:N/A Verified By: Robert Nieminen PE-59166
Design Pressure:N/A Created by Independent Third Party:Yes
Other:Refer to ER Section 5 for Limits of Use. Refer to ER Evaluation Reports
Section 6 for Installation. FL7804 R9 AE 2016 04 FINAL ER ENTEGRA FL7804-
R9 HVHZ.odf
Created by Independent Third Party:Yes
7804.2 Entegra Concrete Roof Tiles(non- Concrete Roof Tile
HVHZ jurisdictions)
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL7804 R9 II 2016 04 FINAL ER ENTEGRA FL7804-
Approved for use outside HVHZ:Yes R9 NON-HVHZ.Ddf
Impact Resistant:N/A Verified By: Robert Nieminen PE-59166
Design Pressure:N/A Created by Independent Third Party:Yes
Other:Refer to ER Section 5 for Limits of Use.Refer to ER Evaluation Reports
Section 6 for Installation. FL7804 R9 AE 2016 04 FINAL ER ENTEGRA FL7804-
R9 NON-HVHZ.Ddf
Created by Independent Third Party:Yes
Back Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275
(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The
emaiis provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please
click here.
Product Approval Accepts:
e`Chie"t
Credit Card
Safe
EXTERIOR RESEARCH &DESIGN,I.I.C.
Certificate of Authorization#9503
\J p� 353 CHRISTIAN STREET,UNIT#13
TPJ I� ERD OXFORD,CT 06478
PHONE:(203)262-9245
FAX:(203)262-9243
EVALUATION REPORT
Entegra Roof Tile,LLC Evaluation Report E39310.11.11-2-R4
TC— 1289 NE 9th Avenue FL7804-119
R -0.0 F `i' I L E Okeechobee, FL 34972 Date of Issuance:11/02/2011
Revision 4:04/18/2016
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code (non-
HVHZ)sections noted herein.
DESCRIPTION: Entegra Concrete Roof Tiles(non-HVHZ jurisdictions)
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen,P.E. if the
product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by:
. The facsimile seal appearing was authorized by Robert Nieminen,
Robert J.M.Nieminen,P.E. .,.c•- „q:T::;•
• P.E.on 04/18/2016.This does not serve as an electronically signed
Florida ,Registration No.59166Florida DCA ANE1983 i�'%`rte ti'
(J � ;Q y;1-,ssss document.Signed,sealed hardcopies have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinitvl ERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
. ' .
TRINITY!ER~
.
0oonma6rs7cm EVALUATION:
l' Scopc:
Product Category: Roofing
Sub-Category: Roofing Tiles
Compliance Statement: Entegro Concrete Roof Tiles, as produced byEntegra Roof Tile, LLC, have demonstrated
compliance with the following sections of the Florida Building Code through testing in accordance with the following
Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth
herein.
2' STAmnmmoa:
Section Property Standard Year
1507.3.5,R905.3.5 Physical Properties ASTM c14yz zooy
1507.3.7,R905.3.7 Attachment Requirements pns4/TmApril zo1z(m4-zz) 2012
1711.2.1 Overturning Moment ssTo1z 1997
3. @spcnsmceS:
EnKPIf Examination Reference Date
ATL(T3T3782) Physical Properties RT0615.01'11 06/28/2011
xTL(rn3782) Physical Properties nTuazs.oz'zz 06/28/2011
ATL(TsTa7oz) Physical Properties nToGzs.os-zz 06/28/2011
xrL(nST3782) Physical Properties nT0615.04-11 06/28/2011
ATL(TsT3782) Physical Properties nT0615.05'11 06/28/2011
ATL(TsT3782) Physical Properties nT0316.01,12 0$31/2012
ATL(TsT37O2) Physical Properties nT1103.01,15 11/07/2015
ATL(TSTs7uz) Physical Properties nTzzosoz'zs 11/07/2015
ATL(rsrsroa) Physical Properties nrzzoa.ns-zs 11/07/2015
ATL(TSTs7uz) Physical Properties nT1103.04-15 11/07/2015
ATL(oTs,o2) Physical Properties nT1103.05'15 11/07/2015
pm(TsTso7u) Physical Properties ss>'001.02'01 11/06/2006
pm(TsTso7o) Physical Properties ss/'002'02-01 11/06/2006
pm(nSTsa7u) Physical Properties ss/'ous'oz'oz 11/06/2006
pn|(TsTsu7u) Physical Properties cS}'un+oz'uz 11/06/2006
pm(TsTsa7o) Physical Properties cs|'uos'ozoz 12/12Y2006
pm(Ts7su7u) Physical Properties xnpoza'uz'oz 11/19/2007
pm(TsTso7o) Physical Properties *np026'02'01 01/08/2008
Tile Roof Institute ssTozz Membership Confirmation Current
pm(Qu*8zzU) Quality Assurance Inspection Report 11/04/2015
Exterior Research and Design,U.C. Evaluation Report csyszo11.11-2-R4
Certificate,/Authorization^95m3 po804-119
Revision 4:04/18/2016
Page uofa
F)o
`J TRINITY'ERD
4. PRODUCT DESCRIPTION:
4.1 BERMUDA FLAT,PLANTATION FLAT and HORIZON FLAT are ASTM C1492,Type III(low-profile)concrete roof tiles.
- 16'
1—lia•
2 K 10• /
------16'
i
30�
ermuda Flat
f 6Lr''
3�
Plantation Flat \
1.3"
' 17-1W
�
Horizon Flat
Exterior Research and Design,I.I.C. Evaluation Report E39310.11.11-2-R4
Certificate of Authorization#9503 FL7804-R9
Revision 4:04/18/2016
Page 3 of 6
iii kc,"?u .'<� ''•s..
TRINIW- j ERD
4.2 BELLA HIGH"S",ESTATE"S"and HACIENDA are ASTM D1492,Typ (medium-profile ncrete roof tiles.
1�" a
Bella High"S"
Naif Holes
•
J61/2,,
1'=
Estate"S"
- a
-3`
Hacienda
Exterior Research and Design,I.I.C. Evaluation Report E39310.11.11-2-R4
Certificate ofAuthorizatian#9503 FL7804-119
Revision 4:04/18/2016
Page 4 of 6
73ll
T'TRINITYIERD
4.3 GALENA SPANISH"S"and REGAL are ASTM C1492,Type I(high-profile)concrete roof tiles.
10"
Gale Spanish"S"
N
t311a"
Regal
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire classification is not part of this evaluation; refer to FBC Section 1505, Exception 2 or current Approved
Roofing Materials Directory for fire rating of this product.
5.4 Underlayment shall be that approved by Entegra Roof Tile, which holds Florida Local or Statewide Product
Approval for use with tile roofing systems. The underlayment Product Approval shall specify allowable
method(s) of tile installation (mechanical attachment, mortar-set and/or adhesive-set) for use with the
specific underlayment. For mortar-set or adhesive-set tile roofing applications, the underlayment Product
Approval shall specify attachment methods for the underlayment system to resist wind uplift design loads in
accordance with Table 1A of FRSA/TRI April 2012(04-12).
5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building
Code and F.A.C.Rule 61G20-3.
Exterior Research and Design,I.I.C. Evaluation Report E39310.11.11-2-R4
Certificate of Authorkadon 119503 FL7804-119
Revision 4:04/18/2016
Page 5 of 6
TRUNITy f ERD
6. INSTALLATION:
6.1 Entegra Concrete Roof Tiles may be mechanically fastened, mortar-set or adhesive-set. Installation shall
comply with manufacturer's current published instructions, but not less than the requirements of FBC
Section 1507.3, the FRSA/TRI Florida High Wind Concrete and Clay Tile Installation Manual, 5th Edition and,
for mortar-set or adhesive-set applications,the mortar or adhesive manufacturers Product Approval.
6.2 Attachment:
Mechanically Attached Tile:
Wind load resistance shall be in accordance with Table 3 of FRSA/TRI April 2012 (04-12) to resist the Uplift
Moment determined in Table 2A or 26 of FRSA/TRI April 2012(04-12).
Mortar-Set or Adhesive-Set Tile:
Wind load resistance shall be in accordance with FBC Section 1609.5.3 in conjunction with the mortar or
adhesive manufacturer's Product Approval.
Hip and Ridge Tile:
Tile shall be installed in accordance with FRSA/TRI April 2012(04-12). For hip and ridge tile installations atop
hip and ridge metal, refer to the hip and ridge metal manufacturer's Product Approval (e.g., FL5374) or test
report in accordance with SSTD 11 for allowable loads to resist those determined in accordance with Table
1A of FRSA/TRI April 2012(04-12).
7. LABELING:
7.1 Each unit shall bear the imprint and/or identifiable marking of the manufacturer's name or logo. Tile lots
shall be labeled in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C. Rule 61G20-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
PRI Construction Materials Technologies, LLC.—QUA9110;(813)621-5777
-END OF EVALUATION REPORT-
Exterior Research and Design,I.I.C. Evaluation Report E39310.11.11-2-R4
Certificate of Authorization 119503 FL7804-119
Revision 4:04/18/2016
Page 6 of 6