Product Approval
USER,V�'Mc'.tw
Q"Om�
FL id FL14645-R2
ApphcaGan Type Re%4slon
Code Version 2014
Application Status Approved
Comments
Archived
Product Manufacturer Metal Sales Manufacturing Corporation
AddresslPhiane/Ernail 545 South 3rd Street,,Suite 200
Louisville,KV 40202
(812)218-7342
risteriner,;,Pmetalsales.us.com
Autharized Signature David Stermer
Technical Representative
Add ress/Ptione/Email
Quality Assurance Reoresentative
'Address/Phbnetern ail
category Rooling
Subcategory Metal Roaring
Compliance Method Evaluation Report ham a floricia(Registered Architect or a Licensed
Honda Professional Engineer
Evaluation Report-Hardcopy Received
Honda Engineer or Architect Name who developed Bela Sockalingam
the Evaluation Repo"
Florida License, PE-62240
Quality Assurance.Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiratfan Date 12/31/20110
Validated By yoosef Livi,P.E.
Validation Checklist-Hardcopy Received
Certificate of Independence
Referenced Standard and Year(of Standard)
fM 4470 1992
TAS 125 2003
UL 1897 1996
UL 1897 2004
UL 580 1.994
UL 580 2006
Equivalen cr of Product Standards
Certified By Florida Licensed professional Engineer or Architect
Sections from the Code
https:/,I%vww,floridabtiildln,g.orgipr/pr_,appjtl.a,-,px)param=NvGEVXQ%�,,tDqs,.%v,8ZVNI'eSA..- '3/22212016
EVALUATION REPORT OF
METAL SALES MANUFACTURING CORPORATION
126 GA. 5V-CRIMP PANEL,'
FLORIDA BUILDING CODE 5"1 EDITION(2014)
FLORIDA PRODUCT APPROVAL
FL 14645.3-112
ROOFING
METAL ROOFING
Prepared For:
Metal Sales Manufacturing Corporation
545 South 3"d Street,Suite 200
Louisville, KY 40202
Telephone: (502)8554300
Far:: (502)8554290
Prepared By:
Bala Sockalingam, Ph.D., P.E.
Florida Professional Engineer#62240
1216 N Lansing Ave.,Suite C
Tulsa,OK 74106
Telephone: (918)492-5992
FAX: (866)366-1543
This report consists of
Evaluation Report(3 Pages including cover)
Installation Details(I Page)
i�1#0 SOC1<qt�''�,�i
No 62240''
Report No. C2010-3
±0. STATE OF :��
Date: 3.27.15
r4 O R`� G`� �.
FL 14645.3-R2
C2010-3
3.27.15
Page 2 of 3
Manufacturer: Metal Sales Manufacturing Corporation
Product Name: 5V-Crimp
Panel Description: 24"wide coverage with 1/2"high ribs
Materials: Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or
Galvalume coated steel (ASTM A792)or painted steel (ASTM A755),
Deck Description: Min. 19/32" thick plywood for new and existing constructions.
Designed and installed as per FBC 2014.
Deck Attachment: 8d x 2.5" long ring shank nails or-48 x 2" long wood screws @ 6" o.c.
(Minimum) in the plywood field and @ 4" o.c. at edges
New Underlaynient: Minimum underlayment as per FBC 2014 Section 1507.4.5.1.
Required for new construction and optional for reroofing construction.
Existing Underlayment: One layer of asphalt shingles over one layer of 430 felt. For reroofing
(Optional) construction only.
Slope: 1/2:12 or greater in accordance with FBC 2014 Section 1507.4.2
Design Uplift Pressure: 41.6 psf @ fastener spacing of 36" o.c.
(Factor of Safety=2) 74.8 psf @ fastener spacing of 16" o.c.
196.75 psf @ fastener spacing of 8" o.c.
Fastener Pattern:
Type: 49-16 or 410-14 hex head wood screws with sealed washer. Fastener
shall be of sufficient length to penetrate through the deck a minimum
of 3/8".
At panel ends @ 6" o.c. across panel width
At intermediate @ 12" o.c. across panel width
Test Standards: Roof assembly tested in accordance with TAS 125-03 'Standard
Requirements for Metal Roofing Systems'.
Code Compliance: The product described herein has demonstrated compliance with FBC
2014 Section 1507.4
Product Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2014 Section 1609 or ASCE 7-10 using allowable stress
7
design. The maximum support spacing listed herein shall not be
exceeded. This evaluation report is not applicable in High Velocity
Hurricane Zone. Fire classification is not within scope of this
Evaluation Report. Refer to FBC 2014 Section 1505 and current
FL 14645.3-R12
C2010-3
3.27.15
Page 3 of 3
approved roofing materials directory or ASTM E108[UL790 report
q
from an accredited laboratory for fire ratings of this product.
ail
4
N "744
Supporting Documents: TAS .125 Test Reports jo,
Farabaugh Engineering and Testing Inc
Project No. T 181-05,Reporting Date 7/21/05(Tests#I & 2)
Project No. T240-09,Reporting Date.9/22/09
Architectural Testing,hie.—West Palm Beach,FL,
(Formerly Hurricane Test Laboratory,LLC)
Project No. 0103-0712-09,Reporting Date 9/1/09
6S OS
ons/?s
EXISTING SHINGLES SEE DETAIL 2 SEE DETAIL 1 NEW URED O YMENT FASTENER AT-PANEL FIAT 5V-CRIMP
(OPTIONAL) _ l {PANEL QiERLAP} NE1Y0 CIONSTRUCTfON)R ENDSREQUIRED
ONLY,FOR PANEL
i AK
n
EXISTING UNDERLAYMENiP� ANEL FASTENER PER ALLOWABLE
(OPTIONAL) MINIMUM ATTACHMENT: PRESSURE TABLE ON THIS SHEET. _
8d x 2.5° LONG RING SHANK NAIL $
OR 18 x 2" LONG WOOD.SCREWS �
SPACED 0 6" D.C. IN THE FIELD &
MIN, 2X_ WOOD RAFTER/JOIST) 3 4" D.C. AT PLYWOOD EDGES
7\s2
TRUSS AT MAX. 24" O.C. `
TYPICAL PANEL INSTALLATION X—SECTION aQo o
a Nq4
09-16 OR #10-14 WOODSCREWS F? v
WITH SELF SEALING WASHER AT ALLOWABLE UPLIFT PRESSURE g a c 1
D Ln
NEW UNDERLAYMENT MAXIMUM SPACING OF 36' O.C. C3 In
(REQUIRED ONLY FOR FASTENER PRESSURE M J m
NEW CONSTRUCTION) ACI(IN (PSF) o
Lo
EXISTING SHINGLES MIN 26 GA_ 36 41.6 �
(OPTIONAL)
16 74.8 'n
S
d 8
ul
EXISTING UNDERIAYMENT PLYWOaF " 'o
(OPTIONAL) DETAIL 9/32'.THICK (MIN.) GENERAL NOTE
t. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE
FLORIDA BUILDING CODE (FBC). I � a
2. ROOF PANELS SHALL BE MIN. 26 GA. (t - 0.0169"). EFFECTIVE COVERING u�i jl
#9-16 OR X10-14 WOODSCREWS WIDTH OF-PANEL = 24".
WITH SELF SEALING WASHER AT 3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS m c
NEW UNOERLAYMENT. �. SPECIFIED ON THIS DRAWING. -
MAXIMUM SPACING OF 36' O.C. u
(REQUIRED ONLY FOR 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS
NEW CONSTRUCTION) PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE'REQUIRED DESIGN WIND LOADS
ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING.
EXISTING SHINGLES 5V-CRIMP 5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS-DRAWING & THE FLORIDA
(OPTIONAL) FAIN 26 GA. BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM
REQUIREMENTS Of THIS DRAWING & THE CODE, THE CODE SHALL CONTROL.
6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS
REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS_
EXISTING UNDERLAYMENT PLYWOOD ,-„ EV
(oPnoNAI) 19/32THICK (MIN.) 2000=3`
DETAIL 2 Z"w i.