HomeMy WebLinkAboutREVISION, revised architect plan 11.17.20 (2)GENERAL NOTES SITE WORK TIMBER 1. ALL WORK DONE UNDER THIS CONTRACT SHALL BE IN COMPLIANCE WITH THE FLORIDA BUILDING CODE RESIDENTIAL (FBCR) 1. REFER TO THE SOILS REPORT FOR SPECIFIC DESIGN REQUIREMENTS (IF REQUIRED BY BUILDING DEPARTMENT), 1, ALL WOODS AND WOOD CONSTRUCTION SHALL COMPLY WITH SPECIFICATIONS AND CODES MODIFICATIONS AS SPECIFIED 6th EDITION, (2017) . ALL REFERENCED CHAPTERS, CODE SECTIONS AND TABLES STATED IN THESE DOCUMENTS ARE UNDER HEREIN: FBCR 6TH EDITION (2017) LINO, 2. REFER TO THE CIVIL DRAWINGS FOR LOCATION OF BUILDING WORKING POINTS, ROUGH GRADING, ON -SITE UTILITIES, A. AMERICAN INSTITUTE OF TIMBER CONSTRUCTION (STANDARDS MANUAL) SITE IMPROVEMENTS, SITE RETAINING WALLS, AND SPECIFIC GENERAL NOTES. THE SOILS REPORT AND CIVIL B. NATIONAL FOREST PRODUCTS ASSOCIATION: 2. WHERE BUILDING LOCATIONS ARE DETERMINED TO BE IN WIND BORNE DEBRIS REGIONS, ALL EXTERIOR DRAWINGS SHALL OVERRIDE CONFLICTS WITH SITE WORK NOTED HEREIN.SEE LANDSCAPE DRAWINGS FOR FINAL I, NATIONAL DESIGN SPECIFICATIONS (NDS) FOR WOOD CONSTRUCTION BUILDING OPENINGS SUCH AS WINDOWS AND DOORS SHALL BE PROTECTED AGAINST WINDBORNE DEBRIS BY FINISH GRADES, PLANTING AND IRRIGATION. C. SOUTHERN PINE INSPECTION BUREAU: THE INSTALLATION OF STRUCTURAL PANELS OR IMPACT -RESISTANT GLASS. THESE OPENING PROTECTIONS SHALL BE I. STANDARD GRADING RULES FOR SOUTHERN PINE LUMBER DESIGNED AND INSTALLED IN ACCORDANCE WITH CHAPTER 3, SECTION R301.2.1.2. 3. ELEVATIONS SHOWN ON THE SITE DRAWINGS ARE MINIMUM REQUIRED DEPTHS, IF DIFFERENT CONTACT THE D. TRUSS PLATE INSTITUTE: ARCHITECT. I. NATIONAL DESIGN STANDARDS FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES (TPI 1-2014) 3. DO NOT SCALE DRAWINGS. THE CONTRACTOR AND SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO WORK E. APA -THE ENGINEERED WOOD ASSOCIATION: PERFORMED AND SHALL NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE FOUND, 4. NO EXCAVATION SHALL BE MADE WHOSE DEPTH BELOW THE FOOTING IS GREATER THAN 1/2 THE HORIZONTAL I. ENGINEERED WOOD CONSTRUCTION GUIDE DISTANCE FROM THE NEAREST EDGE OF THE FOOTING. F. AMERICAN WOOD PRESERVERS ASSOCIATION STANDARDS 4. THE CONTRACTOR SHALL BRING ERRORS AND OMISSIONS WHICH MAY OCCUR IN CONTRACT DOCUMENTS TO THE ATTENTION OF THE ARCHITECT IN WRITING AND WRITTEN INSTRUCTIONS SHALL BE OBTAINED BEFORE PROCEEDING WITH THE WORK. 5. ALL BACKFILL AT STRUCTURES, SLABS, STEPS, AND PAVEMENTS SHALL BE CLEAN GRANULAR FILL. PLACE IN 8" LAYERS 2. ALL LUMBER EXPOSED TO WEATHER, OR AGAINST SOIL, CONCRETE OR MASONRY MUST BE PRESSURE TREATED, THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY ERRORS, DISCREPANCIES OR OMISSIONS IN THE AND COMPACT TO 95% MAXIMUM DRY DENSITY DETERMINED IN ACCORDANCE WITH ASTM D1557. THE BUILDING SITE CONTRACT DOCUMENTS, OF WHICH THE CONTRACTOR FAILED TO NOTIFY THE ARCHITECT BEFORE CONSTRUCTION AND/OR SHALL BE KEPT DRY SO THAT EROSION WILL NOT OCCUR IN THE FOUNDATIONS, 3. MINIMUM NAILING PER CHAPTER 6- WALL CONSTRUCTION AND TYPICAL NAILING SCHEDULE ON PLANS. FABRICATION OF THE WORK, 4. NOTCHING OR CUTTING OF FRAMING MEMBERS SHALL COMPLY WITH CHAPTER 6- WALL CONSTRUCTION, 5. THE ARCHITECT/ENGINEER SHALL NOT BE RESPONSIBLE FOR THE SAFETY AND CONSTRUCTION PROCEDURES, TECHNIQUES, 6. COMPACTION BY FLOODING OR JETTING IS STRICTLY PROHIBITED. OR THE FAILURE OF THE BUILDER TO CARRY OUT THE WORK IN ACCORDANCE WITH THE DRAWINGS OR THE REQUIRED CODES. 5, VVALL. SHEATHING StIALL BE PER STRUCTURAL, SEE ROOF/WALL/FLOOR SHEATHING FASTENER SCHEDULE ON SHEET SN1. 7. DO NOT BACKFILL UNTIL SLABS HAVE CURED OR HAVE BEEN PROPERLY BRACED. (WHERE APPLICABLE) 6. THE STRUCTURAL DESIGN IS BASED ON THE INTERACTION OF ALL PARTS OF THE COMPLETED BUILDING, THE CONTRACTOR 16. MINIMUM DIMENSION OF ANY PLYWOOD SHEET SHALL BE 24" AND THE MINIMUM AREA SHALL BE 8 FT . SO. SHALL SOLELY BEAR THE RISK FOR PROVIDING ADEQUATE STABILITY AND SAFETY OF THE STRUCTURE DURING 8. EXCAVATIONS TO BE A MINIMUM OF 3'- 0" BEYOND NEW FOOTING LINE, CONSTRUCTION UNTIL PERMANENT MEMBERS ARE COMPLETELY INSTALLED. PLUMBING 9. THE GENERAL CONTRACTOR MUST TAKE MEASURES TO CONTROL SOIL EROSION AS PER ALL LOCAL AND STATE 1. SANITARY LINES SHALL BE OF CAST IRON OR PVC (SCHEDULE 40) AS APPROVED BY THE BUILDING OFFICIAL. 7. DETAILS SHOWN ON THE DRAWINGS ARE TO BE CONSIDERED TYPICAL FOR ALL SIMILAR CONDITIONS. REQUIREMENTS. 2. WATER SUPPLY LINES SHALL BE CPVC OR UPONOR PEX "A" (CROSS -LINKED POLYETHYLENE) WITH F1960 FITTINGS. 8. THE CONTRACTOR SHALL MAKE NO STRUCTURAL CHANGES WITHOUT WRITTEN APPROVAL FROM THE ARCHITECT/ENGINEER. 10. CONTRACTOR IS TO VERIFY THE ELEVATION OF THE FINISHED FLOOR SLAB WITH THE SIGNED AND SEALED SURVEY 3. 4. CONDENSATION LINES SHALL BE MINIMUM'/<° PVC (SCHEDULE 40), INSULATED WITH''I " AMAFLEX. SHOWER HEADS SHALL HAVE A FLOW CONTROL DEVICE TO GIVE A MAXIMUM FLOW OF 3 GPM EACH, WHICH COMPLIES WITH ALL LOCAL CODES HAVING JURISTICTION, INCLUDING ALL APPLICABLE STATE, CITY AND 9. NO STRUCTURAL MEMBERS ARE TO BE CUT FOR PIPES, DUCTS, ETC. UNLESS SPECIFICALLY DETAILED. COUNTY BUILDING AND ZONING CODES. IF CONSTRUCTED IN A FLOOD ZONE, SOIL CONDITIONS MUST BE MODIFIED 5. ALL CLEANOUTS SHALL BE FLUSH WITH GRADE. TO PLACE THE FINISHED FLOOR ELEVATION MIN V-0" ABOVE THE BFE, PER FLORIDA BUILDING CODE. 6. NO VENT STACKS SHALL PASS THROUGH ROOF CRICKETS, VALLEYS, OR RIDGES. GARAGES AND CARPORTS 0 7. SIZE AND LOCATION OF CLEANOUTS SHALL CONFORM TO SECTION P3005.2. 11. SWIMMING POOL, DECK, SPA, AND ASSOCIATED WORK IS TO BE PERMITTED SEPARATELY BY ENGINEERED SHOP 8. FIXTURE SUPPLY SIZES SHALL CONFORM TO SECTION P2903, 1. GARAGE DOOR A. ENGINEERED FOR MIN. WIND LOAD, LISTED ON COVER SHEET DRAWING. 9, THE PLUMBER IS TO DIVERT ALL VENTS TO REAR ELEVATION WHEN POSSIBLE. B. DETAIL TO BE SUPPLIED BY GARAGE DOOR SUPPLIER 12. TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING SOIL APPLIED PESTICIDES, 10. DRILLING &.NOTCHING OF WOOD FRAMED STRUCTURAL MEMBERS SHALL FOLLOW PROVISIONS OF SECTION P2603.2. C. DETAIL TO BE ATTACHED TO PERMIT PACKAGE BY BUILDER BAITING SYSTEMS AND PESTICIDES APPLIED TO WOOD, OR OTHER APPROVED METHODS OF TERMITE PROTECTION EXTERIOR WALL COVERINGS 2. AS PER SECTION R302.5.1: OPENINGS FROM A PRIVATE GARAGE DIRECTLY INTO A ROOM USED FOR SLEEPING LABELED FOR USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION, UPON COMPLETION OF THE 1. ALL EXTERIOR WALL COVERINGS AND SOFFITS SHALL BE CAPABLE OF RESISTING THE DESIGN PRESSURES SPECIFIED FOR PURPOSES SHALL NOT BE PERMITTED, OTHER OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE EQUIPPED WITH APPLICATION OF THE TERMITE PROTECTIVE TREATMENT, A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE THE WALLS FOR COMPONENTS AND CLADDING LOADS IN ACCORDANCE WITH TABLE R301,2(2) AS MODIFIED BY TABLE SOLID WOOD DOORS NOT LESS THAN 1 3/8 INCHES IN THICKNESS, SOLID OR HONEYCOMB CORE STEEL DOORS NOT LESS THAN BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: R301.2(3), MANUFACTURED SOFFITS SHALL BE TESTED AT 1.5 TIMES THE DESIGN PRESSURE 1-3/8 INCHES THICK, OR 20-MINUTE FIRE -RATED DOORS, THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. TREATMENT IS IN ACCORDANCE WITH RULES AND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF EXTERIOR FINISHES 3. AS PER SECTION R302.5.2: DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE AGRICULTURE AND CONSUMER SERVICES." 1. WHEN PLASTERING WITH CEMENT, PLASTER SHALL NOT BE LESS THAN THREE COATS, %" THICK, OVER FRAMED WALLS DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM NO.26 GAGE (0.48 MM) SHEET STEEL 1" MIN, RIGID APPLIED OVER PAPER BACKED METAL LATH OR WIRE FABRIC LATH AND WITH TWO LAYERS OF VAPOR BARRIER, NOT LESS ON -METALLIC CLASS OR CLASS 1 DUCT BOARD OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE THAN 2 COATS, 1/2" THICK, WHERE APPLIED OVER MASONRY OR CONCRETE, GARAGE. 2. STUCCO OR PORTLAND CEMENT PLASTER SHALL BE INSTALLED, PROPORTIONED AND MIXED IN ACCORDANCE WITH 4. PER SECTION R3G & TABLE RD THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND ITS ATTIC AREA BY NOT - ,, , 3. ASTM-C926 & ASTM-C1063-12a. LATH & ACCESORIES PER ASTM-C-1063-11 A & R703.7.1. ALL STUCCO APPLICATION DETAILS, INCLUDING BUT NOT LIMITED TO: LESS THAN %-INCH GYPSUM BOARD APPLIED TO THE GARAGE SIDE. GARAGES BENEATH HABITABLE ROOMS SHALL BE LE P AP - , n =: ALL STUCCO CONTROL JOINTS KICK -OUT DETAILS SEPARATED FROM ALL HABITABLE ROOMS ABOVE BY NOT LESS THAN 5 / 8 -INCH TYPE X GYPSUM BOARD OR EQUIVALENT, WHERE THE SEPARATION IS A FLOOR -CEILING ASSEMBLY, THE STRUCTURE SUPPORTING THE SEPARATION SHALL ALSO BE 1"FLASHING HORIZONTAL LATH AND PAPER DETAILS PROTECTED BY NOT LESS THAN'/ -INCH GYPSUM BOARD OR EQUIVALENT, PIPE PENETRATION DETAILS VENT PENETRATION DETAILS WEEP SCREED DETAILS CONDUIT PENETRATION DETAILS CASING BEAD DETAILS DRIP EDGE DETAILS CANTILEVER DRIP EDGE DETAILS CORNER BEAD DETAILS WINDOW CASING DETAILS STUCCO TO SIDING TRANSITION DETAILS WINDOW FLASHING DETAILS 4, SHALL BE INSTALLED PER ASTM-C1063 -15A AND R703.7, FIRE RESISTANT CONSTRUCTION UNDER STAIR PROTECTION: 1, ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS, UNDER STAIR SURFACE AND ANY SOFFITS PROTECTED ON THE ENCLOSED SIDE WITH 1/2" GYPSUM BOARD. R302.7, EXTERIOR CEILINGS 1. EXTERIOR CEILING TO BE 1/2" GOLD BOND BRAND EXTERIOR SOFFIT BOARD INSTALLED PERPENDICULAR TO THE FRAMING MEMBERS. THE 1/2" GOLD BOND BRAND EXTERIOR SOFFIT BOARD IS TO BE SECURED TO THE FRAMING MEMBERS WITH 1 1/4" TYPE "W" DRYWALL SCREWS AT 12" O.C. (PER MANUFACTURER'S SPECIFICATIONS) . CONSTRUCTION OBSERVATION CONSTRUCTION OBSERVATION SERVICES / CONSTRUCTION ADMINISTRATION SERVICES ARE NOT APART OF AB DESIGN GROUP'S SERVICES FOR THIS PROJECT. IT IS UNDERSTOOD AND AGREED THAT AB DESIGN GROUP'S SCOPE OF SERVICES DOES NOT INCLUDE PROJECT OBSERVATION OR REVIEW OF THE BUILDER'S/CONTRACTOR'S PERFORMANCE OR ANY OTHER CONSTRUCTION PHASE SERVICES, AND THAT SUCH SERVICES WILL BE PROVIDED BY THE BUILDER. THE BUILDER ASSUMES ALL RESPONSIBILITY FOR INTERPRETATION OF THE CONTRACT DOCUMENTS, AND FOR CONSTRUCTION OBSERVATION. REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCCE REVISION FILE COPY 551 S. APOLLO BLVD., SUITE �02 MELBOURNE, FLORIDA32901 PH: 321-802-3591 www. a b d es i g rigro u p. com AA #: 0003325 a w sumxV. 8e LOT: CREE IDE LOT 104 PROJECT 04321.200 104R1 MODEL: 4EHHB "2605-HAYDEN" GARAGE WING: LEFT PAGE: GENE AL NOTES V60 MPH EXP. OCT 2 3 2020 MICHAEL C. AINDERSON AR NO 17305 r s &&a + DATE: 10 14 19 ' SCALE:1/4"-1'-O"