Permit Set_MEP Plans_Lot 7
ELECTRICAL NOTES: HVAC GENERAL NOTES: m ALL MATERIALS AND METHODS TO BE IN COMPLIANCE WITH THE 6TH EDITION (2017) FLORIDA BUILDING CODE: POWER PROVISIONS (PP) ALL MATERIALS AND METHODS TO BE IN COMPLIANCE WITH THE 6TH EDITION (2017) FLORIDA BUILDING CODE: MECHANICAL, 6TH EDITION (2017) FLORIDA �ZF . 1 . ELECTRICAL PROTECTION: _ ° ELECTRICAL, 6TH EDITION (2017) FLORIDA BUILDING CODE: RESIDENTIAL & 6TH EDITION (2017) FLORIDA BUILDING CODE: RESIDENTIAL & 6TH EDITION (2017) FLORIDA BUILDING CODE ENERGY CONSERVATION. W. cs � BUILDING CODE ENERGY CONSERVATION. A. GROUND FAULT PROTECTION SHOULD BE APPLIED TO ALL EXISTING & NEW AREAS PER NEC. 1 . BUILDER SHALL PROVIDE A HIGH EFFICIENCY CENTRAL HEAT PUMP AIR CONDITIONING SYSTEM WITH SUPPLEMENTAL ELECTRICAL HEAT TO MEET SITE AND GENERAL REQUIREMENTS (S) B. PROVIDE GROUND FAULT INTERRUPT BREAKERS FOR ALL BATHROOM, GARAGE AND EXTERIOR THE FOLLOWING REQUIREMENTS: � 1 . ALL OUTLETS AND LIGHTS ARE DESIGNED AS PART OF A BASIC ELECTRICAL PACKAGE AS REQUIRE BY OUTLETS AND AS SHOWN. A. SINGLE/MULTI-ZONE AS SHOWN ON PLANS WITH SEPARATE CONDENSER AND AIR HANDLING FOR EACH ZONE. > 3 C. ALL RECEPTACLES MUST HAVE ARC FAULT CURRENT INTERRUPTERS PER NEC. THE FLORIDA BUILDING CODE. COORD. LIGHTING PACKAGE WITH ID/ OWNER, FOR ADDITIONAL FIXTURES B. MINIMUM SEER OF 14.0, MINIMUM COP OF 3.3 @ 47°db. OR REVISED LOCATIONS. ANY CHANGE TO THIS PACKAGE HAS TO BE NOTIFIED TO THE ARCHITECT PRIOR 2. ALL RECEPTACLE OUTLETS TO BE IN PER FBCR E3901 . C. CALCULATE LOADS BASED ON: 72 DEGREES HEATING / 75 DEGREES COOLING. FBC 6TH EDITION (2017) ENERGY CONSERVATION R302 c U OU TO INSTALLATION. 3. SURGE PROTECTION: PROVIDE CUTLER-HAMMER VISOR SERIES SURGE PROTECTION DEVICE AT ALL D. WHERE A DAMPER SYSTEM IS EMPLOYED WITH MORE THAN ONE (1) THERMOSTAT ALLOWING FOR INDIVIDUAL CLIMATE CONTROL OF ¢ 0 2. CONTRACTOR SHALL VERIFY WITH POWER COMPANY THE LOCATION AND LIMITATIONS OF SERVICE. THE PANELS. SEPARATE SPACES WITHIN THE SAME ZONE OF CONDITIONING, A VARIABLE SPEED UNIT IS REQUIRED. SINGLE AND/OR 2 SPEED SYSTEMS N 4. LIGHTNING PROTECTION: PROVIDE AN ALT. BID FOR THE FOLLOWING: N E CONTRACTOR SHALL VERIFY POWER METER LOCATION REQUIREMENTS FROM THE SERVICE COMPANY. SHALL NOT BE USED. w UL LISTED, MASTER LABEL LIGHTNING PROTECTION SYSTEM - (CLASS 1 - COPPER). E. HVAC CALCULATIONS, MAX 15% SAFETY FACTOR. PROVIDE BALANCE MEANS WITHIN ACCESSIBLE LOCATIONS OR MANUAL DAMPERS.3. CONTRACTOR SHALL USE A LICENSED ELECTRICAL CONTRACTOR FOR THE MINOR ADDITION, w RELOCATION AND REMOVAL FOR ALL ASSOCIATED EQUIPMENT. HIGH VOLTAGE SURGE ARRESTOR AT METER - (CLASS 3 UNIT). o 2ND STAGE HIGH VOLTAGE SURGE ARRESTORS AT SUB-PANELS IN BASEMENT, GARAGE, MECH/ELEC. Q o o 4. GAS SERVICE: NOTICE TO CONTRACTOR/HOMEOWNERS ROOMS - CATEGORY 'B'. 0 SEE SITE PLAN FOR LOCATION OF UNDERGROUND LP GAS TANK ( ) THE FOLLOWING IS REQUIRED WHEN DESIGNING A PROJECT AS AN "� > OR 5. ALL WIRE SHALL BE THW COPPER, UNLESS NOTED OTHERWISE. 6. WHERE REQUIRED BY OTHER CODES, SERVICE AND FEEDER CONDUCTORS SHALL BE COPPER OF EQUAL UNVENTED ATTIC STRUCTURES FBC R806.5 SPRAY FOAM THERMAL ENVELOPE �> PROVIDE NATURAL GAS METER AND SERVICE AS REQUIRED FOR ALL NOTED APPLIANCES. COORDINATE ( ) LOCATION OF GAS METER W/ GAS COMPANY. AMPACITY. U > N C 8. ELECTRICAL SERVICE. PROVIDE UNDERGROUND SERVICE TO METER. PROVIDE REQUIRED CHASES TO 7. ALL BRANCH CIRCUITS IN RACEWAY OR NON METALLIC SHEATHED CABLE. 1 . ALL AHU'S (AIR HANDLERS) ARE TO BE LOCATED WITHIN THE THERMAL ENVELOP (CONDITIONED AREA) OF MECH/ELEC. ROOM TO HOUSE ALL MAIN C/O PANELS. SUB-PANELS LOCATED THROUGHOUT HOME - SEE 98.. NOTCOORDINATE RACEWAY INSTALLATIONS WITH OTHER TRADES PRIOR TO CONSTRUCTION. ELECTRICAL PLAN THE STRUCTURE. IF THE AHU IS LOCATED WITHIN THE ATTIC PORTION OF THE THERMAL ENVELOP, IT SHALL � o 9. POOL EQUIPMENT VERIFY W/ POOL CONTRACTOR POWER REQUIREMENTS FOR ALL POOL / WATERFALL / 10. VERIFY ALL CONDUCTORS AND BREAKERS WITH EQUIPMENT MANUFACTURER'S SPECIFICATIONS. BE WITHIN A ROOM SEPARATED FROM THE SPF BY DRYWALL OR A THERMAL BARRIER TO ALLOW FOR 0- SPA o N EQUIPMENT PRIOR TO CONSTRUCTION 11. PROVIDE DISCONNECT SWITCH OF SIZE AS REQUIRED BY LOAD AND UNITS. SUPPLY & RETURN AIR TO CONDITION THIS ROOM s 10. IRRIGATION CONTROLS: PROVIDE POWER & CONTROLS FOR PUMP OR RECYCLED WATER SUPPLY 12. PROVIDE NON-FUSIBLE GENERAL DUTY SAFETY SWITCHES AT A/C EQUIPMENT, AND AT PUMPS NOT CONTROL VALVE. VERIFY W/ OWNER/LANDSCAPE ARCHITECT VISIBLE FROM CIRCUIT. O 11. FIXTURE AND EQUIPMENT VERIFICATION: 13. BREAKER AND PANEL AS PER MANUFACTURER'S RECOMMENDATIONS. 2. MONITORING AND CONTROL OF HUMIDITY IN ATTIC SPACES : (j) o o r4 A. VERIFY FINAL EQUIPMENT SCHEDULE AND LOCATION WITH OWNER, INTERIOR DESIGNER REFLECTED 14. VERIFY HOOD ELEC. REQ. WITH MANUF. SPECS. BID ONE 110V GFI OUTLET INSIDE CABINETRY ABOVE a. IT IS REQUIRED THAT AN ERV SYSTEM BE APART OF EACH SYSTEM (ZONE), INSTALLED PER MANUF. 0 CEILING PLAN, & FURNITURE PLACEMENT LAYOUT. GRILL FOR HOOD. COORD. GRILL/RANGE HOOD WITH CABINETRY PACKAGE. WRITTEN INSTRUCTIONS �' x �` 15. PROVIDE 2" PVC ELEC. CHASE TO PROVIDE POWER TO KITCHEN ISLAND. It B. ELECTRICAL FIXTURES, TRIM AND APPLIANCES SHALL BE UL RATED AND APPROVED FOR THE FIXTURE USE AND LOCATION TYPE: INCLUDING BUT NOT LIMITED TO ICF FIXTURES, WET AND DAMP 16. COORD. ELECTRICAL REQUIREMENTS FOR WATER HEATER WITH PLUMBER , INSTALL PER MANUF. SPECS. b. IT IS RECOMMENDED TO THAT A DEHUMIDIFIER (DR 90) , 1 PER EVERY 4000 S.F. OF AREA, BE ADDED FOR LOCATIONS, ETC. 17. ELECTRICAL GENERATOR: PROVIDE AN ALTERNATE BID FOR A 60 KW SINGLE PHASE LP GAS POWERED ADDITIONAL HUMIDITY CONTROL TO COVER ALL AREAS WITHIN THE THERMAL ENVELOPE N C. ALL SW'S & RECEPTACLES TO BE 'DECOR ' GROUP - ROCKER PLATES VERIFY COLOR W/ GENERATOR AND ATS TO PROVIDE POWER FOR GENERAL LIGHTING, POWER, AND ALL REFRIGERATION ti OWNER/INTERIOR DESIGNER. PROVIDE 20A RECEPTACLES W/ 'T' SLOT WHERE NOTED APPLIANCES AS REQUESTED BY OWNER. 2. RETROFITTING AN EXISTING VENTED STRUCTURE TO AN UNVENTED SPRAY FOAM STRUCTURE IN NOT o D. AT LOCATIONS WITH 3 OR MORE SWITCHES COORD. PASS & SEYMOUR "DECORATOR COMBINATION RECOMMENDED UNLESS THE ENTIRE STRUCTURE IS EXPOSED AND ALL VENDORS & SUBCONTRACTORS 0 SWITCHES" W/ OWNER. LIGHTING PROVISIONS (LP) E. OUTDOOR LIGHTING - COORD. ADDITIONAL LIGHTS TO BE LOCATED PER THE LANDSCAPE PACKAGE 1 . ALL FLUORESCENT FIXTURES TO UTILIZE LOW-NOISE, ENERGY SAVING BALLAST AND BULBS. SEAL ALL PENETRATIONS TO THE EXTERIOR AS REQUIRED BY ALL JURISDICTIONAL AGENCIES. IMF o w/ ELECTRICAL CONTRACTOR. VERIFY OUTDOOR LIGHTING WITH OWNER/ LANDSCAPE ARCHITECT. 2. PROVIDE A LIGHTING CONTROL SYSTEM AS MANUF. BY LUTRON OR CRESTRON AS INDICATED WITHIN �--' THESE DOCUMENTS. UTILIZATION OF THESE SYSTEMS DOES NOT GUARANTEE THE PREVENTION OF THE GROWTH OF MOLD DUE TO CONSTRUCTION RELATED F. COORD. EXTERIOR WP ELECTRICAL OUTLET LOCATIONS FOR CHRISTMAS LIGHTS, AND CENTRAL •- c•+� LIGHT SWITCH FOR CHRISTMAS LIGHTS WITH OWNER. 3. PROVIDE A SURFACE MOUNTED LIGHT FIXTURE WITH A PULL CORD SWITCH AT ATTIC AREAS WHERE AHU DEFICIENCIES IN THE BUILDING ENVELOP THAT RESULTS IN MOISTURE AND VAPOR INTRUSION INTO THE STRUCTURE. G. COORD. FINAL LOCATION AND ADDITIONAL TV, TELEPHONE, DATA AND ELEC. OUTLETS, WITH IS MOUNTED IN ATTIC. SEE HVAC GENERAL NOTES. U OWNER TYP. 4. INTERIOR & EXTERIOR STAIR / STEPS LIGHTING SHALL COMPLY WITH FBC R303.7. ** .NOTE TO END USERS: FOR A CLOSED SPRAY FOAM STRUCTURE (RESIDENCE), ALL MECHANICAL DESIGNS ADHERE TO THE DESIGN SPECIFICATION AND GUIDELINES SET FORTH BY ASHRAE AND ASSUME MINIMAL INTRODUCTION OF OUTSIDE AIR AND THE DESIGN HEATING AND THE H. COORD. LOCATION OF FLOOR OUTLETS WITH ID/OWNER IN FIELD. SYSTEM(S) ARE DESIGNED TO MEET COOLING TEMP'S OF 72 d HEATING/ 75 d COOLING AT 55% HUMIDITY (+/-). OPERATING THESE SYSTEMS OUTSIDE OF Q I. ALL BASE FLOOR OUTLETS TO BE MOUNTED HORIZONTALLY IN BASE BOARD WHERE APPLICABLE. THESE DESIGN PARAMETERS COUPLED WITH THE INTRODUCTION OF UNCONDITIONED OUTSIDE UNCONDITIONED AIR ABOVE AND BEYOND THESE VERIFY W/ INTERIOR DESIGNER IN FIELD. DESIGN GUIDELINES ( i.e. leaving door & window units open for extended lengths of time MAY LEAD TO THE FORMATION OF CONDENSATION & MOLD GROWTH J. COORD. WITH INTERIOR DESIGNER AND OWNER FINAL REMOTE POWER LIGHTING DESIGN. SECURITY AND COMMUNICATIONS (SC) ( � 9 p 9 ) K. VERIFY LOCATION OF CHIME IN FIELD W/ OWNER PRIOR TO INSTALLATION 1 . SECURITY SYSTEM VERIFY W/ OWNER/SECURITY CONTRACTOR LOCATION OF SECURITY PANEL AND WITHOUT THE UTILIZATION OF MECHANICAL SYSTEMS THAT CONTROL BOTH TEMPERATURE AND HUMIDITY AND/OR MAINTAINING A CLOSED L. COORD. OCCUPANCY SENSOR LOCATIONS WITH ID/OWNER. POWER/TELECOMMUNICATION REQUIREMENTS. ENVIRONMENT WHICH MEET THE DESIGN STANDARDS WHICH THESE SYSTEMS FOLLOW ** M. COORD. LOCATION OF SWITCHES IN LIEU OF AUTOMATED LIGHTING CONTROL SYSTEM WITH 2. PRE-WIRE ALL OPENINGS FOR OWNER'S INSTALLED SECURITY SYSTEM ER. 3. PROVIDE POWER TO SECURITY SYSTEM, VERIFY LOCATION WITH OWNER/CONTRACTOR IN FIELD 3. ELECTRIC STRIP HEATERS SHALL BE MOUNTED IN AIR HANDLER UNITS AND SHALL BE UL APPROVED WITH HIGH LIMIT CUT-OFF. ID/OWN N. ID/OWNCOORD MOTORIZED SHADES/CURTAIN LOCATIONS & ELEC. REQUIREMENT W/ OWNER / INTERIOR 4. PROVIDE PRE-WIRED TELEPHONE OUTLETS AS SHOWN ON PLANS. VERIFY LOCATIONS IN FIELD W/ OWNER 4. WHERE SYSTEMS ARE POWERED BY NATURAL GAS (GAS HEAT), PROVIDE FRESH AIR SUPPLY & EXHAUST AS REQUIRED. ER VIF 5. PROVIDE PRE-WIRED TELEVISION OUTLETS (CABLE TV) AS SHOWN ON PLANS. VERIFY LOCATIONS IN FIELD 5. HVAC CONTRACTOR SHALL PROVIDE COMPLETED AIR CONDITIONING LOAD CALCULATIONS & FLORIDA MODEL ENERGY CODE FORMS SIGNED AND DESIGN O. DESIGNCOORD ADDITIONAL UNDER COUNTER APPLIANCES, NOT SHOWN, WITH OWNER, INTERIOR DESIGNER W/ OWNER. SEALED BY A FLORIDA REGISTERED ENGINEER OR LICENSED MECHANICAL CONTRACTOR TO BUILDER PRIOR TO FABRICATION AND INSTALLATION. CABINETRY PACKAGE . PROVIDED ELEC. OUTLETS AS REQUIRED PER MANUF. SPECS. 6. TELECOM OPTION: PROVIDE STRUCTURED CABLE FOR THE FOLLOWING: CALCULATE LOADS BASED IN ITEM 1 .C. ABOVE. AND P. AND CACOORD ADDITIONAL ELECTRICAL OUTLETS FOR OFFICE EQUIPMENT WITH OWNER/INTERIOR A. MIN. (2) - 24 AWG 4 PR CAT 6 CABLE HOME RUN TO CENTRAL LOCATION FOR ALL VOICE & DATA 6. PROVIDE SUPPLY DUCTS TO ALL MAJOR LIVING AREAS INCLUDING WALK IN CLOSETS & PANTRY'S. PROVIDE DUCTED RETURNS FROM ROOMS THAT DESIGNER AND CABINETRY CONSULTANT. APPLICATIONS ARE SEPARATED FROM OTHER ROOMS BY A DOOR, AS ALLOWED BY CODE. USE AIR TRANSFER GRILLS WHERE PHYSICAL LIMITATIONS PREVENT A Q. COORD. ELEC. WALL AND FLOOR OUTLET LOCATIONS W/ CABINETRY PACKAGE & OWNER / INTERIOR B. MIN. (2) - 18 AWG QUAD SHIELDED RG 6U COAX CABLE FOR ALL VIDEO DISTRIBUTION DUCTED RETURN. ER. 7. PROVIDE HEAD END PANEL FOR STRUCTURED TAI 570 COMPLIANT DATA NETWORK W/ 15 AMP DEDICATED 7. COORD. FINAL LOCATION AND STYLE OF DIFFUSERS AND THERMOSTAT WITH ID/ OWNER. DESIGN R. DESIGNCOORD LOCATION & TYPE OF FIXTURE ABOVE KITCHEN ISLAND WITH ISLAND DESIGN. CIRCUIT. 8. HVAC CONTRACTOR SHALL VERIFY ALL AHU/COMPRESSOR LOCATIONS W/ MANUF. RECOMMENDATIONS & LOCAL BUILDING CODES WITH REGARD S. COORD. LOW VOLTAGE LIGHTING REQUIREMENTS AT ALL CLOSETS WITH OWNER, INTERIOR TO SPACE REQUIREMENTS & ACCESS REQUIREMENTS FOR SERVICE AND OPERATION. NOTIFY BUILDER/ ARCHITECT WITH ANY REVISION TO DESIGNER PACKAGE AND CLOSET CONSULTANT. FACILITATE COORDINATION WITH STRUCTURAL REQUIREMENTS & LAYOUT. T. COORD. UNDER COUNTER LIGHTING REQUIREMENTS WITH OWNER/CABINETRY CONSULTANT. LIFE SAFETY (LS) 9. DUCT WORK TO BE 1 %2" R-6 FOIL FACED ANTI-MICROBIAL FIBERGLASS DUCT BOARD. SEAL CONNECTION AT TOP HAT WITH FIBERGLASS / MASTIC OR N U. COORD. DIMMERS AND TIMERS WITH OWNER/ ID. 1 . SMOKE ALARMS SHALL BE PROVIDED IN ACCORDANCE WITH FBC R314. UL LISTED DUCT TAPE. � 2. WHEN MORE THAN ONE SMOKE ALARM IS REQUIRED THE DEVICES SHALL BE WIRED IN SUCH A MANNER 10. ALL DUCT JOINTS TO BE SEALED WITH FIBERGLASS MESH AND DUCT MASTIC. DUCT TAPE IS NOT PERMITTED. o 15. ALL INTERIOR DESIGN SPECIFICATIONS MUST BE NOTIFIED TO ARCHITECT OF RECORD OR PROJECT 11 . DUCTS IN GARAGES PENETRATING WALLS OR CEILINGS SEPARATING THE DWELLING SHALL BE MIN. NO. 26 GA. SHEET STEEL OR CLASS 1 DUCT � ) MANAGER PRIOR TO CONSTRUCTION THAT THE ACTUATION OF ONE UNIT WILL ACTIVATE ALL UNITS PER FBC R314.5. a� H = � 3. ALL EXISTING & NEW BEDROOMS SHALL HAVE NEW SMOKE DETECTORS INSTALLED IN AREAS LOCATED BOARD PER FBC R302.5.2 c 3 16. ALL FIXTURES SHALL BE UL APPROVED. a� No U - C)ON PLAN(S). EACH FLOOR SHALL FAVE A MIN. OF (1) SMOKE ALARM. FBC R314.3 12. CAVITIES IN FRAMED SPACES, SHALL NOT BE USED TO DELIVER AIR TO OR FROM THE CONDITIONING SYSTEM. w 17. SEE THEATER DESIGNER SPECIFICATIONS FOR ALL THEATER EQUIPMENT AND PLACEMENT IF 13. INSULATE REFRIGERATION IN SUCTION LINE TO A MIN. OF R-3 WITH ARMAFLEX RUBBER INSULATION. = m J 4. SMOKE ALARMS SHALL RECEIVE THE PRIMARY POWER FROM DIRECT WIRE INTO THE BUILDING AND ALSO o w APPLICABLE. _ BE PROVIDED WITH A BATTERY BACKUP SYSTEM. WIRING SHALL BE PERMANENT AND WITHOUT A 14. PRIMARY CONDENSATE DRAIN LINES MUST BE INSULATED ON ALL RUNS. CONDENSATE LINES SHALL BE MIN. 3/4" DIAMETER PVC (SCHEDULE 40) 18. SEE ALLOWANCE SCHEDULE FOR ALL OWNER PROVIDED FIXTURES. ELECTRICAL SUBCONTRACTOR TO E cL DISCONNECT SWITCH OTHER THAN THOSE FOR OVERCURRENT PROTECTION. FBC R314.4 INSULATED WITH AMAFLEX INSULATION. o 0 Q INCLUDE ALL RECESSED CANS AND UTILITY FIXTURES IN BASE BID. E z3 a- 19. PROVIDE INSTERSYSTEM BONDING TERMINATION PER FBCR E3609.3. 5. CARBON MONOXIDE ALARMS SHALL BE PROVIDED IN ACCORDANCE WITH FBC R315. 15. HORIZONTAL UNITS: PROVIDE CONDENSATE DISPOSAL AT ALL COILS ON WHICH CONDENSATION WILL OCCUR, INCLUDING ALL AIR-HANDLING UNITS, O m J 6. PROVIDE A CARBON MONOXIDE ALARM WITHIN 10 FEET OF EACH ROOM USED FOR SLEEPING PURPOSES. PROVIDE DRAINS, AND 2" DEEP GALVANIZED METAL DRAIN PANS WITH A WATER LEVEL DETECTION DEVICE THAT WILL SHUT OFF THE EQUIPMENT Q v z0 U) FBC R315.1 . PRIOR TO OVERFLOW OF THE DRAIN PAN IN ACCORDANCE WITH FBCR M1411 .3, FBCR M1411 .4 AND ALL SUB-SECTIONS.. WHEN THE WATER LEVEL IN i THE CONDENSATE LINE FAILS TO PERFORM. j EXHAUST FANS (EF) 16. VERTICAL UNITS: PROVIDE A FLOAT SWITCH IN "P" TRAP TO SHUT THE UNIT DOWN Q 1 . ALL EXHAUST FANS SHALL BE PROVIDED WITH A TIMER / SWITCH. 17. ALL AIR-HANDLING UNITS SHALL HAVE A MINIMUM OF 4" CLEARANCE ALL AROUND THE AIR HANDLER AND 36" CLEARANCE AT THE SERVICE SIDE. FBCR M1305.1.1 . 18. SET CONDENSING UNITS ON A 4" CONCRETE SLAB WITH MINIMUM 18" CLEARANCE ON ALL SIDES AND MIN 36" CLEARANCE AT THE SERVICE SIDE. FBCR M1305.1.4.1 19. ATTICS CONTAINING APPLIANCES, INCLUDING AIR HANDLING EQUIPMENT, SHALL BE PROVIDED WITH AN OPENING AND A CLEAR AND UNOBSTRUCTED PASSAGEWAY LARGE ENOUGH TO ALLOW REMOVAL OF THE LARGEST APPLIANCE IN ACCORDANCE WITH FBCR M1305.1.3 . 20. ATTICS CONTAINING APPLIANCES, INCLUDING AIR HANDLING EQUIPMENT, SHALL BE PROVIDED WITH A LUMINAIRE, SWITCH, AND RECEPTACLE OUTLET IN ACCORDANCE WITH FBCR M1305.1 .3.1 21 . WHERE 'ICYNENE' AND/ OR OTHER SPRAY FOAM INSULATION IS USED TO CREATE A SEALED ENVELOPE: A. MECHANICAL DESIGNER TO REVIEW VENTILATION REQUIREMENTS. STALE AIR AND CONTAMINANTS CAN ACCUMULATE IN A HOME WITHOUT PROPER VENTILATION. MAKE-UP AIR OR AN AIR EXCHANGER IS REQUIRED TO INSURE THAT SUFFICIENT FRESH AIR IS INTRODUCED TO THE BUILDING FOR ACCEPTABLE INDOOR AIR QUALITY. B. MECHANICAL DESIGNER TO REVIEW HVAC EQUIPMENT SIZING. THE EFFICIENCY OF THIS TYPE OF INSULATION METHOD MAY REQUIRE LESS HVAC POWER RISER TONNAGE TO EFFECTIVELY CONDITION THE BUILDING. OVERSIZED UNITS LEAD TO COOL DAMP ENVIRONMENTS WITH POTENTIAL FOR CONDENSATION, MOLD, AND MILDEW PROBLEMS. OUTDOOR INDOOR DIAGRAM C. MECHANICAL DESIGNER TO REVIEW HUMIDITY CONTROL REQUIREMENTS. A DEHUMIDIFIER IS NECESSARY TO CONTROL HUMIDITY IN THE KEYNOTES: BUILDING. 4 00 A B 1> 400 AMP, 120/240 V, 10 PLUMBING NOTES: UNDERGROUND ELECTRICAL p ALL MATERIALS AND METHODS TO BE IN COMPLIANCE WITH THE 6TH EDITION 2017 FLORIDA BUILDING CODE: PLUMBING, 6TH EDITION O SERVICE BY GROUND PEDESTAL BY F.P.C. ( ) ( ) [RE].2017 FLORIDA BUILDING CODE: RESIDENTIAL & 6TH EDITION 2017 FLORIDA BUILDING CODE: ENERGY CONSERVATION 2� � 2 5 3� 3#500 MCM, THWN, CU-3 1/2" 1 . SANITARY LINES SHALL BE OF CAST IRON, OR PVC (SCHEDULE 40) AS SELECTED BY BUILDER. 5 CONDUIT. 2. WATER SUPPLY LINES SHALL BE COPPER, TYPE "L" , OR ' CPVC ' AS APPROVED BY FLORIDA BUILDING CODES �, ° Q O ED> ® 400 AMP METER BASE W/2- CAI 3. HOT WATER LINES MUST BE INSULATED,FULL LENGTH, THROUGH AND BELOW CONCRETE SLABS TO MIN R-2 WITH ARMAFLEX 200 AMP MAIN BREAKERS INSULATION �■i w "' ti o U. 5� 4/0 SERAL WIRE _ F- � p - 1 V © CO #4 BARE COPPER WIRE TO 4. PROVIDE AIR CHAMBER FOR ALL WATER SUPPLIES. ' o Q L c - - FOOTER STEEL 5. COPPER WATER LINES WHICH RUN UNDER SLABS SHALL BE PROTECTED BY MIN. 12" EARTH COVER, AND SLEEVED 12" BELOW AND . 0 200 AMP, MLO, 120/240V, 10, ABOVE THE SLAB. L POWER RISER DIAGRAM N-1, 42 SPACES PANEL BOARD. 6. PROVIDE EMERGENCY PAN UNDERNEATH ELECTRIC/ GAS TANK WATER HEATERS. METAL OR PVC PANS SHALL BE GALVANIZED AND E E: ( F.P.C. - 400A, 120/240, 1 O ) N.T.S. RUST PROOFED. PROVIDE DRAIN LINE FROM PAN TO EXTERIOR OF BUILDING, TO MEET THE REQUIREMENTS OF FBCR M1411 .3, M1411.4 a AND ALL SUB-SECTIONS. 7. FIXTURE WATER FLOW RATES TO COMPLY WITH FBC: PLUMBING TABLE 604.4. ° 3 O GERERAL CONTRACTOR/ELECTRICAL CONTRACTOR TO CONTACT ARCHITECT PRIOR TO INSTALLATION OF SERVICE IF 8. FIXTURE SUPPLY SIZES SHALL CONFORM TO FLORIDA BUILDING CODE. ALL -WATER CLOSETS SHALL BE WATER SAVING 1 .6 GALLON m SERVICE SIZE IS TO BE INCREASED/DECREASED, ANY REVISIONS TO POWER RISER DIAGRAM FLUSH TYPE L - U p 9. WATER HEATER. o A. ELECTRIC TO MEET MINIMUM EFFICIENCIES LISTED IN TABLE C404.2 FBC: ENERGY CONSERVATION [CE] . }� s GENERAL NOTES: B. GAS TO MEET THE CRITERIA IN THE FBC. L .3 1. GENERAL CONTRACTOR/ ELECTRICAL CONTRACTOR TO CONTACT ARCHITECT PRIOR TO INSTALLATION OF SERVICE IF SERVICE SIZE IS TO BE INCREASED/DECREASED, ANY REvlsloNs To POWER RISER DIAGRAM. 10. ALL CLEANOUTS FLUSH WITH GRADE. SIZE AND LOCATION OF CLEANOUTS SHALL CONFORM TO FLORIDA BUILDING CODE PLUMBING. 11 . NO VENT STACKS SHALL PASS THROUGH ROOF CRICKETS, VALLEYS, RIDGES, OR WITHIN 18" OF FASCIA OR PARAPETS. Q■ N 2. PROVIDE ALL SERVICE EQUIPMENT AND CIRCUIT BREAKER PANELS WITH AIC RATING, OR SERIES RATING NOT LESS THAN 12. PLUMBER TO DIVERT ALL VENTS TO REAR ELEVATION. 3 THE SHORT CIRCUIT AMPS AVAILABLE FROM THE POWER COMPANY TRANSFORMER. VERIFY WITH THE POWER COMPANY 13. GANG ALL STACKS TO FACILITATE THE MIN. NUMBER OF ROOF PENETRATIONS AS POSSIBLE " PRIOR TO ORDERING MATERIALS. Q o 14. HOSE BIBS TO BE PROVIDED WITH BACKFLOW PREVENTER. 3. PROVIDE A TRANSIENT VOLTAGE SURGE PROTECTOR AT EACH/EVERY PANEL. CONNECT VIA 30-AMP CB WITH SHORT 15. THE PLUMBING CONTRACTOR SHALL PROVIDE A HOSE BIB AT THE POOL EQUIPMENT LOCATION AND SHALL LOCATE A POOL-FILL LINE MEP L STRAIGHT LEADS. PROVIDE U.L. LISTED PROTETORS WITH NOT LESS THAN 80K AMPS PER PHASE RATINGS. WHEN A MAIN F/S WITH A VACUUM BREAKER. HOSE BIB TO BE LOCATED BEFORE WATER TREATMENT SYSTEM IF APPLICABLE. IS ALSO SHOWN, PROVIDE U.L. LISTED LIGHTNING ARRESTOR ON THE LOAD SIDE. 2 18. PLUMBING FIXTURES, TRIM, ACCESSORIES, COLORS, ETC. SHALL BE SELECTED BY OWNER FROM BUILDER'S OFFERINGS. 1� a 0 ■ 1 NL 19. COORD. FINAL PLUMBING FIXTURE SELECTION WITH INTERIOR DESIGNER/ OWNER 20. COORD. POT FILLER LOCATION WITH INTERIOR DESIGNER/ CABINETRY PACKAGE/OWNER o 21 . COORD. WATER SOFTENER W/ OWNER. 3 SHEET NO 2 POOL NOTES: m ALL MATERIALS AND METHODS TO BE IN COMPLIANCE WITH THE 6TH EDITION (2017) FLORIDA BUILDING CODE: PLUMBING, 6TH EDITION N ° N (2017) FLORIDA BUILDING CODE: RESIDENTIAL & 6TH EDITION (2017) FLORIDA BUILDING CODE: ENERGY CONSERVATION [RE]. E 1 . PROVIDE A LINE TIED DIRECTLY FROM THE "FILL" LOCATION, UNDER POOL DECK (SLEEVED IN PVC PIPE) INTO TILE BAND AREA OF THE N o POOL. COORDINATE ALL WORK WITH POOL CONTRACTOR TO VERIFY LOCATIONS. s 2. ALL POOL PLUMBING MATERIAL AND MECHANICAL REQUIREMENT MUST COMPLY WITH FBCR 4501 ~ not valid without z 3. ALL POOL PLUMBING AND RELATED EQUIPMENT SHALL BE PROVIDED BY POOL CONTRACTOR AND SHALL BE PERMITTED SEPARATELY. 0 original or electronic SEE POOL CONTRACTOR'S ENGINEERED SHOP DRAWINGS. PLUMBIN CONTRACTOR SHALL PROVIDE TWO (2) COPIES OF "AS-BUILT" O signature &seal N o RISER DIAGRAMS AND PLAN LOCATIONS TO OWNER ° N �� �L O L ; O O N 0 3 Accuracy Statement Mark P. Nasrallah This item has been digitally signed and sealed by Mark P Nasrallah on the date contained Fla. Reg. AR 0008136 within the digital signature above. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies LIGHTING LEGEND: o U N NOTE:VERIFY'ROUND'OR'SQUARE' FIXTURES E FOR ALL DOWNLIGHT APPLICATIONS y o y C N C ALL EXTERIOR LIGHTS TO BE UL EXTERIOR RATED FOR WET LOCATIONS. N m N L� NOTE: NOT ALL FIXTURES SHOWN IN THE ; 0 3 LEGEND ARE USED IN THE PROJECT. VERIFY ON C N PLAN � U O ®A INTERIOR RECESSED LED LIGHT- FIXTURE BY OWNER/DESIGNER d © EXTERIOR RATED RECESSED LED LIGHT. C C FIXTURE BY OWNER/DESIGNER. © LOW VOLTAGE RECESSED LIGHT- FIXTURE BY o OWNER/DESIGNER. 9 VAPOR PROOF RECESSED LED LIGHT- FIXTURE Q BY OWNER/DESIGNER. C C � c � E 6 m 0. o c > o PEE J INT.SURFACE MTD. - FIXTURE BY OWNER/ID U N K EXT. SURFACE MTD. - FIXTURE BY OWNER/ID — — — — — — — INDOOR SMALL PENDENT CHANDELIER- FIXTURE BY OWNER/DESIGNER I — INDOOR LARGE CHANDELIER- FIXTURE BY — — \ OWNER/DESIGNER N U OUTDOOR CHANDELIER- FIXTURE BY I \ OWNER/DESIGNER. SEE NOTE (9) UNDER O d LIGHTING PROVISIONS. i \ I EXTERIOR WALL BRACKET- FIXTURE BY (!) Q (Z OWNER/DESIGNER fn z i N 1 \ I I I P INTERIOR WALL BRACKET- FIXTURE V �S x I� I / \ I I \x BY OWNER/DESIGNER I n WALL MOUNTED ART LIGHT. - FIXTURE BY OO OWNER/DESIGNER � \ / / \ / S i 00 •. N I �i ISLAND PENDANT N �+ \ _ / / I / TRAC LIGHTING- FIXTURE BY OWNER/ }, OI — 1 — \ I T DESIGNER. VERIFY LOCATION PRIOR TO O N, \ I INSTALL V W \ \ / GROIN VAULT WALL SCONCE-COVE LIGHT FIXTURE BY OWNER/DESIGNER }, N — — — — — — — — — — I I ( VERIFY LOCATION PRIOR TO INSTALL _ �I — — — 3 q Cl) TRUSS LIGHTING 11 S —— UNDER COUNTER LIGHTING- FIXTURE ps �1J d^1� I 71 I I I BY ID/OWNER. VERIFY LOCATION / \ @ �C V / I PRIOR TO INSTALL i I I A A� I CLG. COVE LIGHTING FIXTURE BY Q ID/OWNER RECESSED FLOOR LIGHT 1. ALL SELECTIONS SHALL BE UL p RATED/APPROVED FOR TYPE AND LOCATION. — �� I 2. ALL LIGHTS SHALL BE RECESSED / GFI — — � J FLUSH WITH FINISH FLOOR A A A A MATERIAL. ® I TO KITCHEN, / WALL SCONCE- FIXTURE BY / I � I \ \ OV OWNER/DESIGNER LIGHTS (` I I \ p _ VERIFY LOCATION PRIOR TO INSTALL CHASE FOR \ I \ \ I RECESSED STEP LIGHTING- FIXTURE ISLAND ELEC. GFI BY OWNER/DESIGNER RD EX FAN EXT. SECURITY/MOTION LIGHTING - FIXTURE BY OWNER/DESIGNER-VERIFY FIELD LOC'T W/OWNER/LANDSCAPE \ XI/ LOCATION I Ot 42" 41 ARCHITECT. III �DP II I N GFI per/ �� WEDGE SCONE UP LIGHT / \ 0 \ AT PEDESTALS RECESSED WALL 1 MOUNTED LIGHT. LIGHTS IN WET A D i� \\ CONDITIONS SHALL BE WATER PROOF ELF /III\\ �lil�• AND UL RATED FOR THE TYPE / LOCATION OF USE. - FIXTURE BY N \ y \ \ / I ❑ I I (�EX F TO KIT I GFI OWNER/DESIGNER \ TO SWITCH \ � � \ � \ I\I I I � `� /�LIGHTS GFI FIUEMAX XTURE BY FULL SPECTRUMLIGHTING � ♦.r OJ BELOW \ TO SWITCH I I ° A A W A BELOW � A \ `j/— — _ TO FAMILY RM. / I JY W D I �jTO PENDANT I 0) H _ J q /WRAP AROUND,AS SELECTED BY / LIGHTS — 2Xa OWNER. TO SWITCH TO SWITCH \ �3 LIGHTS /- I \ / � = U � BELOW BELOW ELECTRICAL LEGEND LLI C a o ® FIELD VERIFY ! I I I LL M — SWITCH = m 0 J O WIC LOCATION _————, LL o \ TO IR _ I a2° �z W E I 42' GFI — — 3 ■ W U U _ __` o — I I I �IG T E — — w . - - 3-WAY SWITCH 2 EL W ice — _ � � I Pc ICL I I I I I = a o � 'v Q i @LT,——/ � / I I 3 __ GFI 4-WAY SWITCH O m J 11 ATTIC �� I F� I� �I D I �X� II 1i I I I � SWITCH - DIMMER U � z I I —— \ I LEVITON DECORA TRIPLE-ROCKER J EX'AN A-s— KIP\ 6/8/12 BUTTON KEYPAD 110V. DUPLEX CONVENIENCE OUTLET W/ARC E:3 I I \ FAULT INTERRUPTER 2 ARC FAULT CURRENT INTERRUPTER SWITCHED OUTLET X \ �J F' GFI DUPLEX OUTLET w/MOUNTING HEIGHT A.F.F. \ \ I/ I €X\ \ \ q / I IGAR OPNR A \ (II)@CLGR OPNR z p W P \/ / \ Tf Q w GFI DUPLEX OUTLET W/WATERPROOF HOUSING I \I II \� I ( CP LEVITON WALL SWITCH/RECEPTACLE#5626- GAR QDR GAR DR?q RECTRACTABLE SCREEN/SHADE POWER SUPPLY / / \ S (12V/110V)VERIFY \ — — A A I \\ N, \\ �oAA QUADPLEX OUTLET 20a DEDICATED \ 220V. OUTLET. 20A/30A VERIFY PLUG I I — TYPE/POWER REQ'T / / / —� ulNennA+a-NEMA 14-50 TESLA OUTLET(50 AMP-6 AWG) / I a UCA UNDER COUNTER APPLIANCE. VERIFY POWER / / I REQUIREMENTS I ®zoo 220V. HARDWIRE OUTLET 1 / I FLOOR OUTLET- PROVIDE CONDUIT CHASE AS REQUIRED VERIFY LOCATION W/ INTERIOR I I\ I IV r \ DESINGER/OWNER 1/2 SWITCHED FLOOR OUTLET- PROVIDE CONDUIT O — — — — — — — — — — — — — — — — — — — — — — — — — — — J II / II 1 — — — — — — — — ® CHASE AS REQUIRED VERIFY LOCATION W/ INTERIOR DESIGNER/OWNER Q z / I TELE-DATA FLOOR OUTLET- INCLUDE CAT 5 z A A ® OUTLET AS REQUIRED.V.I.F. PROVIDE CONDUIT Q CHASE AS REQUIRED VERIFY LOCATION W/ p — — — — INTERIOR DESIGNER/OWNER Z Lu \ SD SMOKE DETECTOR-SEE LIFE SAFETY NOTES 1-6 CD E-- U a CV p Cs COMBINATION CARBON MONOXIDE/SMOKE w ti zz U DETECTOR-SEE LIFE SAFETY NOTES 1-6 ■� ¢ o U) (D THERMOSTAT Q a Q PC PULL CORD 0 TE U C SECOND FLOOR FIRST FLOOR qPe PUSH BUTTON o N CABLE OUTLET ° 2 POWER & LIGHTING PLAN POWER & LIGHTING PLAN 110 CFM EXHAUST FAN -"NUTONE"QTXEN150 (140 0 3 SCALE 3/16" = 1'-0" SCALE 3/16" = 1'-0" EX.FAN S.F.) QTXEN110 (100 S.F.)QTXEN80 (75 S.F.) SPECIFIED MOTOR t DISPOSAL MOTOR W/ 110 V HARDWIRE OUTLET w �DISP 0 TELE-DATA OUTLET- INCLUDE CAT 5 OUTLET AS t a 3 REQUIRED.V.I.F. MOUNT @ 12"A.F.F. U.N.O. a TIA 570 COMPLIANT STRUCTURED CABLE OUTLET (2) CAT 5 OUTLETS , (2) RG 6U COAX OUTLETS OHGD I OVERHEAD GARAGE DOOR OPENER Q N 9 RPM REMOTE POWER MODULE y O @ T LIGHTING MAIN KEYPAD VIF FINAL LOCATION WITH LKP OWNER DISC DISCONNECT SWITCH ■� 2 CHIME DOOR BELL CHIME _ a) - 1 . 0 N LANDSCAPE JB- PROVIDE CONDUIT CHASE AS Im ° LDSCP REQUIRED VERIFY LOCATION W/LANDSCAPE SHEET NO o ARCH./OWNER 2 p_a c ELECTRICAL_CEAN MLO_LV LIGHTING_A/V PANEL o 0 PANEL y m E EW ELECTRIC METER N Q U X I 1 52" CEILING FAN W/LIGHT FIXTURE - FIXTURE BY not valid without / OWNER/DESIGNER 0 original or electronic m signature &seal '2 x 1000 CFM VARIABLE SPEED THRU WALL EXHAUST o FAN W. EXTERIOR WALL SHUTTER N 3 O L > N �N �3 Accuracy Statement Mark P. Nasrallah This item has been digitally signed and sealed by Mark P Nasrallah on the date contained Fla. Reg.AR 0008136 within the digital signature above. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies