Loading...
HomeMy WebLinkAboutDesign Load Compliance_Lot 7 Planning&Development Services Department • Building&Code Regulations Division M ' 2300 Virginia Avenue, Fort Pierce, FL 34982—(772)462-1553 Certification for Design Load Compliance Project Name: TRM Construction -Avalon by the Beach Project Address: Lot 7 Avalon By The Beach St. Lucie County, FL Permit#: Occupancy Type:SFR Construction Type:V INSTRUCTIONS FOR USE: • This certification must be completed,signed,and sealed by the design professional of record. • Submit(2)copies for residential, (3)copies for commercial with all permit applications involving the following: o New Residences(single or multi-family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official.Contact the#above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code Sixth Edition with 20 17 Supplements using ASCE 7-10 2. Structure Designed as(check one): X Enclosed Partially Enclosed Open 3. Risk Category: I X II III IV Exposure Category: B C X D 4. Design Wind Velocity 170 mph X ASD LRFD End Zone Width:4 ft 5. Mean Roof Height 25,667 ft Roof Pitch:6 :12 Parapet:- ft 6. Components&Cladding Design Pressures Used: (PSF,based on 10sgft @ 15'MRH,clearly label on all plan openings): Zone 1:26.4/42.0 Zone 2:26.4/-73.1 Zone 3:26.4/-108.1 Zone 4:45.9/49.8 Zone 5:45.9/-61.4 Garage: 45.8/-51.8 7. Design Loads: Floor:40 PSF Roof/Dead:20 PSF Roof/Live:20 Balcony:40 PSF Dock: 100 PSF Deck:60 PSF Stairs:40 PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure:2000 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adeauate resistance to the design forces specified: This item has been digitally signed and sealed by Carl A.Brown, \\ \,A B/�0**-*4f,� P.E.On Signing Date:I1/II/2020 using a Digital Signature. P�••E NS'•(•L�1i��� G � Printed copiesofthis documentare notconsidered signed and ••�' �••• i sealed and the signature must be verified on any electronic No 56126 copies. Engineer's S&S is only for the structural portions of the drawings. -p Any non-structural details or drawings(Electrical,HVAC, — - STATE OF Waterproofing,Driveway layout,etc.)are for information only Q • 44/ and are not part of the FOR review. '���•�( O f3,Q \\� Signature, Date, and Seal f US ENUINEEKINU ASSLJUTA I ES.249 Maitland Ave,SU ,/�,SS/O••••' !�0 % NA Company Name&Address # 'W\\\ Revised 12/07/2018