Loading...
HomeMy WebLinkAboutREVISION, 11.18.20 e1l'� C\ OFFICE USE ONLY: L DATE FILED: b PERMIT# REVISION FEE: RECEIPT# PLANNING &DEVELOPMENT SERVICES ILDING&CODE REGULATION DIVISION 14 , 2300 VIRGINIA AVENUE FORT PIERCE,FL 34982.5652 RECEIVED (772)462-1553 NOV I_ 3 2020 APPLICATION FOR BUILDING PERMIT REVISIONS Permitting Department PROJECT INFORMATION St. Luce County LOCATION/SITE ADDRESS: DETAILED DESCRIPTION OF PROJECT REVISIONS: CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: C,C 2 `i 5'`� ST. LUCIE CO CERT.#: BUSINESS NAME: /6,;-j ',o c� QUALIFIERS NAME:. ffe x e. -PA✓,-j- ADDRESS: CITY: STATE: ZIP: Z PHONE (DAYTIME): FAX: OWNER/BUILDER INFORMATION: NAME: V1 U)1 ADDRESS: ► j 'tip o I Gl-yaw•` IAV,6, _ CITY: I --E. STATE: _z- ZIP: 3 ' PHONE(DAYTIME: Z 1 ' U ` C - ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: L ` '" Gv` Nlrhd lblb Way CITY-' balYO 6"N. STATE: Lj ZIP: G�G ? PHONE( AYTIME): -77 _ ,7 �� 47 SLCCC: 9123109 Revised 06130117 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential PerformammNethod ProjectName: BRANSON TROSKA BuilderName: CAL BUILDERS Street: 7106 BANYAN ST. Permit Office: ST.LUCIE COUNTY Permitting Department City,State,Zip: FT.PIERCE,FL, PermitNumber: St, Lucie County Owner: BRANSON TROSKA Ju. diction: ST.LUCIE COUNTY DesignLocation: FL,Fort Pierce ty: St.Lucie(Florida Climate Zone 2) 1. New construction or existing New( gPla - 9. Wall Types(1240.0 sgft.) Insulation Area 2. Single family or multiple family Si ' I -a mi a.Concrete Block-Int Insul,Exterior R=4.0 1096.00 ftz b.Concrete Block-Int Insul,Adjacent R=11.0 144.00 ftz 3. Number of units,if multiple famil?4%e, 3 c.N/A R= fI2 4. Number of Bedrooms d.N/A R= ftz 5. Is this a worst case? No 10.Ceiling Types (1312.0 sgft.) Insulation Area a.UnderAttic(Vented) R=30.0 1312.00 ftz 6.Conditioned floor area above grade(ftz) 1312 b.N/A R= ftz Conditioned floor area below grade(ftz) 0 c.N/A R= ftz 11.Ducts R - ftz 7. Windows(116.8 sgft.) Description Area a.Sup:Attic,Ret:Attic,AH:Garage 6 325 a. U-Factor: Sgl,U=0.32 76.76 ft SHGC: SHGC=0.22 b. U-Factor: Sgl,U=0.30 40.00 ftz 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.28 a.Central Unit 24.0 SEER:16.00 c. U-Factor: N/A ftz SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftz a.Electric Strip Heat 27.0 COPA.00 SHGC: Area Weighted Average Overhang Depth: 2.560 ft. Area Weighted Average SHGC: 0.241 14.Hot water systems a.Electric j' t f• -_ �, Cap:40 gallons 8. Floor Types (1312.0 sgft.) Insulation Area Edge Insulation R=0.0 1312.00 ftz ` U ilL'' j'��J r'�j _"�,U� 'y��/ EF:0.950 a.Slab-On-Grade Ed 9 b.Conservation features�_ `� b.N/A R= ftz None c.N/A R= ftz 15.Credits CF,Pstat Glass/Floor Area: 0.089 Total Proposed Modified Loads: 45.17 PASS Total Baseline Loads: 45.99 I hereby certify that the plans and specifications covered by Review of the plans and O Zuz.sr this calculation are in compliance with the Florida Energy specifications covered by this Off, Code. calculation indicates compliance with the Florida Energy Code. F. uru;.1w -:;; ?°•.• ,� 0' PREPAR BY: Before construction is completed r , ' DATE: 2-20 this building will be inspected for ; compliance with Section 553.908 I herebycertify that this building,as designed, is in compliance Florida Statutes. fY 9� 9 P with the Florida Energy Code. GOD_'"z v OWNER/AGENT: eal-f -r BUILDING OFFICIAL: DATE: JT13- DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in actor c�ei _ . I�.�a� is project equIres an envelope leakage test report with envelope leakage no greater than 7.00 ACH (R402.4. i�BING BIVIBION FOR 7O�CR REVIEWED BY DATE PLANS AND PERMIT MUST BE KEPT ON JOB OR 11/12/2020 6.43 AM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2 17)(p=plimlt f Qftnal WILL BE MADE Pag 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: BRANSON TROSKA Bedrooms: 3 Address Type: StreetAddress Building Type: User ConditionedArea: 1312 Lot# OwnerName: BRANSON TROSKA Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: No PlatBook: BuilderName: CAL BUILDERS RotateAngle: 0 Street: 7106 BANYAN ST. Permit Office: ST.LUCIE COUNTY CrossVentilation: No County: St.Lucie Jurisdiction: ST.LUCIE COUNTY Whole House Fan: No City,State,Zip: FT.PIERCE, FamilyType: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design DailyTemp DesignLocation TMYSite 97.5% 2.5% Winter Summer DegreeDays Moisture Range FL,Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1312 10496 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 MASTER BEDROO 195 1560 No 2 1 1 Yes Yes Yes 2 WIC 42 336 No 0 1 Yes Yes Yes 3 BATH 1 66 528 No 0 1 Yes Yes Yes 4 LIVING ROOM 548 4384 Yes 0 1 Yes Yes Yes 5 BEDROOM#3 158 1264 No 1 1 1 Yes Yes Yes 6 BATH#2 54 432 No 0 1 Yes Yes Yes 7 BEDROOM#2 168 1344 No 1 1 1 Yes Yes Yes 8 HALL 28 224 No 0 1 No Yes Yes 9 LAUNDRY 53 424 No 0 0 1 Yes Yes Yes FLOORS # FloorType Space Perimeter PerimeterR-Value Area JoistR-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulation MASTER BEDRO 13 ft 0 195 ft2 ---- 0 1 0 2Slab-On-Grade Edge Insulation WIC 13ft 0 42ft2 ---_ 0 1 0 3 Slab-On-Grade Edgeinsulation BATH 1 lift 0 66ft2 ---- 0 1 0 4 Slab-On-Grade Edgelnsulation LIVING ROOM 37 ft 0 548 ft2 ---- 0 1 0 5 Slab-On-Grade Edge Insulation BEDROOM#3 26 ft 0 158 f12 ---- 0 1 0 6 Slab-On-Grade Edgelnsulation BATH#2 6 ft 0 54 ft2 ---- 0 1 0 7Slab-On-Grade Edge Insulation BEDROOM#2 31ft 0 168ft2 ---- 0 1 0 11/12/2020 6:43 AM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 2 of 5 J FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # FloorType Space Perimeter PerimeterR-Value Area JoistR-Value Tile Wood Carpet 8Slab-On-Grade Edge Insulation HALL 1 ft 0 28ft2 ---- 0 1 0 9 Slab-On-Grade Edgelnsulation LAUNDRY 14 ft 0 53 ft2 ---- 0 0 1 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1421 ft2 0 ft2 Unfinishe N 0.6 No 0.7 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio(1in) Area RBS IRCC 1 Full attic Vented 150 1312 ft2 N N CEILING # CeilingType Space R-Value Ins Type Area Framing Frac Truss Type 1 UnderAttic(Vented) MASTER BEDRO 30 Blown 195ft2 0.1 Wood 2 UnderAttic(Vented) WIC 30 Blown 42ft2 0.1 Wood 3 UnderAttic(Vented) BATH 1 30 Blown 66 ft2 0.1 Wood 4 Under Attic(Vented) LIVING ROOM 30 Blown 548ft2 0.1 Wood 5 Under Attic(Vented) BEDROOM#3 30 Blown 158W 0.1 Wood 6 Under Attic(Vented) BATH#2 30 Blown 54ft2 0.1 Wood 7 Under Attic(Vented) BEDROOM#2 30 Blown 168ft2 0.1 Wood 8 UnderAttic(Vented) HALL 30 Blown 28ft2 0.1 Wood 9 Under Attic(Vented) LAUNDRY 30 Blown 53ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N Exterior Concrete Block-Int InsuMASTER BE 4 13 0 8 0 104.0 ft? 0 0 0.4 0 2 W Exterior Concrete Block-Int Insul WIC 4 7 0 8 0 56.0 ft2 0 0 OA 0 3 N Exterior Concrete Block-Int Insul WIC 4 6 0 8 0 48.0 ft2 0 0 OA 0 4 W Exterior Concrete Block-Int Insul BATH 1 4 11 0 8 0 88.0 ft2 0 0 0.4 0 5 S Exterior Concrete Block-Int InsuLIVING ROO 4 1 0 8 0 8.0 ft2 0 0 0.4 0 6 S Exterior Concrete Block-Int InsuLIVING ROO 4 18 0 8 0 144.0 ft2 0 0 OA 0 _ 7 S Exterior Concrete Block-Int InsuLIVING ROO 4 18 0 8 0 144.0 ft2 0 0 0.4 0 8 E Exterior Concrete Block-Int InsuBEDROOM# 4 14 0 8 0 112.0 ft2 0 0 0.4 0 _ 9 N Exterior Concrete Block-Int InsuBEDROOM# 4 12 0 8 0 96.0 ft2 0 0 0.4 0 10 E Exterior Concrete Block-Int Insul BATH#2 4 6 0 8 0 48.0 ft2 0 0 OA 0 _11 E Exterior Concrete Block-Int InsuBEDROOM# 4 14 0 8 0 112.0 ft2 0 0 0.4 0 12 S Exterior Concrete Block-Int InsuBEDROOM# 4 12 0 8 0 96.0 ft2 0 0 0.4 0 _13 W Exterior Concrete Block-Int InsuBEDROOM# 4 5 0 8 0 40.0 ft2 0 0 OA 0 _14 NW Garage Concrete Block-Int InsuLIVING ROO 11 18 8 144.0 ft2 0 0 0.4 0 11/12/2020 6:43 AM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DOORS # Omt DoorType Space Storms U-Value Width Height Area Ft In Ft In 1 E Insulated LIVING ROO None .39 3 6 8 20 ftz 2 NW Insulated LIVING ROO None .39 2 8 6 8 17.8 ftz WINDOWS Orientation shown isthe entered,Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation IntShade Screening 1 N 1 Vinyl Low-ESingle Yes 0.32 0.22 Y 11.0 ft' 2 ft,0 in 1 ft 3.5 in None None 2 S 6 Vinyl Low-ESingle Yes 0.32 0.22 Y 21.8 ftz 5 ft 0 in 1 ft 3.5 in INone None 3 S 7 Vinyl Low-ESingle Yes 0.3 0.28 Y 40.0 ftz 2 ft 0 in 1 ft 3.5 in None None 4 S 7 Vinyl Low-E Single Yes 0.32 0.22 Y 11.0 ftz 2 ft 0 in 1 ft 3.5 in None None 5 N 9 Vinyl Low-ESingle Yes 0.32 0.22 Y 16.4 ft' 2 ft 0 in 1 ft 3.5 in None None 6 S 12 Vinyl Low-ESingle Yes 0.32 0.22 Y 16.4 ft' 2 ft 0 in 1 ft 3.5 in None None GARAGE # FloorArea CeilingArea Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 378 ftz 378 ftz 18 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000356 1224.5 67.23 126.43 .1233 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER:16 24 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert# CompanyName System Model# CollectorModel# Area Volume FEF None None ftz 11/12/2020 6:43 AM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DUCTS —Supply— —Return— Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area LeakageType Handler TOT OUT QN RLF Heat Cool 1 Attic 6 325 ft2 Attic 65 ft2 DefaultLeakage Garage (Default)c(Default)c 1 1 TEMPERATURES ProgramableThermostat: Y Ceiling Fans: CoolingJan Feb Mar Apr [ ]may [X]Jun [X]Jul [X]Au n S Oct Nov Dec Heatin HJan H Feb N Mar Apr [ ]May ( ]Jun E )Jul E ]Aug Sep Oct NNov Nov H Dec Ventin Jan Feb Mar [X]A r [ ]Ma [ l Jun ]Jul ]Au Se [X]Oct Dec ThermostatSchedule: HERS 2006 Reference Hours ScheduleType 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 .68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area - Thickness Fumitu re,Fraction Space Default(8lbs/sq.ft. 0 ft2 Oft 0.3 MASTER BEDROO Default(8lbs/sq.ft. ft2 ft 0.3 WIC Default(8lbs/sq.ft. ft2 ft 0.3 BATH 1 Default(8lbs/sq.ft. ft2 ft 0.3 LIVING ROOM Default(8lbs/sq.ft. ft2 ft 0.3 BEDROOM#3 Default(8lbs/sq.ft. ft2 ft 0.3 BATH#2 Default(8lbs/sq.ft. ftz ft 0.3 BEDROOM#2 Default(8lbs/sq.ft. ft2 ft 0.3 HALL Default 8lbs/s .ft. 0 ft2 Oft 0.3 LAUNDRY 11/12/2020 6:43 AM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 5 of 5 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX*=98 The lower the Energy Performance Index, the more efficient the home. 1. New home or,addition 1. New(From Plans) 12. Ducts, location&insulation level a)Supply ducts R 6.0 2. Single-family or multiple-family 2. Single-family b)Return ducts R 6.0 c)AHU location Garage 3. No.of units(if multiple-family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 24.0 a)Split system SEER 16.0 5. Is this a worst case?(yes/no) 5. No b)Single package SEER c)Ground/water source SEER/COP 6.Conditioned floor area(sq.ft.) 6. 1312 d)Room unit/PTAC EER e)Other 7.Windows,type and area a) U-factor:(weighted average) 7a. 0.313 b)Solar Heat Gain Coefficient(SHGC) 7b. 0.241 14. Heating system: Capacity 27.0 c)Area 7c. 116.8 a)Split system heat pump HSPF b)Single package heat pump HSPF 8.Skylights c) Electric resistance COP 1.0 a)U-factor:(weighted average) 8a. NA d)Gas furnace, natural gas AFUE b)Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace, LPG AFUE f)Other 9. Floor type,insulation level: a)Slab-on-grade(R-value) 9a. 0.0 b)Wood, raised(R-value) 9b. 15.Water heating system c)Concrete, raised(R-value) 9c. a)Electric resistance EF 0.95 b)Gas fired, natural gas EF 10.Wall type and insulation: c)Gas fired, LPG EF A. Exterior: d)Solar system with tank EF 1.Wood frame (insulation R-value) 10A1. e)Dedicated heat pump with tank EF 2.Masonry(Insulation R-value) 10A2. 4.0 f)Heat recovery unit HeatRec% B.Adjacent: g)Other 1.Wood frame (Insulation R-value) 10B1. 2. Masonry(Insulation R-value) 10132. 11.0 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a)Ceiling fans Yes a)Under attic 11a. 30.0 b)Cross ventilation No b)Single assembly 11b. c)Whole house fan No c)Knee walls/skylight walls 11c. d)Multizone cooling credit d)Radiant barrier installed 11d. No e)Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features which will be installed(or exceeded)in this home before final inspection. Otherwise,a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New Home: 7106 BANYAN ST. City/FL Zip: FT.PIERCE,FL 11/12/2020 6:43:36 AM EnergyGauge®USA 6.0.04(Rev.1)-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 Project Summary u te: -�- wrightsoft® Entire House By. QUICK CALLS,INC. 317 ST.LUCIE LANE,FORT PIERCE,FL34946 Phone:772-466-�5799 Email:QUICKCALCS AOL.COM Project Information For. BRANSON TROSKA 7106 BANYAN ST.,FT.PIERCE,FL Notes: Design Information Weather: Fort Pierce,FL,US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 15617 Btuh Structure 11399 Btuh Ducts 3030 Btuh Duds 3556 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 18647 Btuh Use manufacturer's data n Rate/swin multiplier 0.95 Infiltration Equipmen�sensible load 14207 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2691 Btuh Duds 1185 Btuh Central vent(0 cfm) 0 Btuh Heatingg Coolingg (none) Area(fF) 1312 1312 Equipment latent load 3876 Btuh Volume(ff3) 11808 11808 Air changesthour OA5 0.23 Equipment Total Load(Sen+Lat) 18083 Btuh Equiv AVF(cfm) 89 45 Req.total capacity at 0.70 SHR 1.7 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTR40251-1 AHRI ref Coil TEM6AOB24H21++TDR AHRI ref 7567540 Efficiency 100 EFF Efficiency 13.0 EER,16 SEER Heating Input 5.0 kW Sensible cooling 16800 Btuh Heating output 17137 Btuh Latentcooling 7200 Btuh Temperature rise 50 OF Total cooling 24000 Btuh Actual airflow 312 cfin Actual airflow 800 cfm Airflowfactor 0.017 cfm/Btuh Airflowfactor 0.053 c n/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.79 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -rW wr toft ighs ® 2020-Nov-1 2 06:42:51 ACC11 ^� Right Sute®Uriversa1201919.021 RSU08101 Page 1 KoonmertslWrighboft WACITROSKA,BRANSON.n{r Carc=W8 Front Door faces:NW +wrightsoft Right-J®Worksheet Job: Entire House Date: By. QUICK CALCS, INC. 317 ST.LUCIE LANE,FORT PIERCE,FL34946 Phone:772-466-6799 Email:QUICKCALCS@,AOL.COM 1 Room name Entire House MASTER BEDROOM 2 E)posed viell 166.0 It 13.0 It 3 Room height 9.0 It 9.0 It heaU000l 4 Room dimensions 13.0 x 15.0 It 5 Room area 1312.0 ft2 195.0 fF Ty Construction U-value Or HTM Area (fl) Load Area (ft2) Load number (Btuh#F2F) (Btu or perimeter (ft) (BWh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W= 13A ._.__�M 0.,143. D___ _4.00..,___2.19_,-,__.306� _.__3W _.�.1225---. 669-_...__ ;0 _..._.0 m_�._._.�0.__ 13A4om 0.143 a 4.00 2.19 270 212 847 463 0 0 0 0 4A5-20b 0.560 a 15.68 42.07 16 1 256 687 0 0 0 0 4A5-20b 0.560 a 15.68 29.01 22 12 339 628 0 0 0 0 11 11DO 0.390 a 10.92 10.34 20 20 223 211 0 0 0 0 W_. 13Aocs�- _-----,_0.143. s -4.00 _2.19 _.189_..__.-189--_._-_757 ots _ 414 -...- O e'_ 0._ _ 0 0 W 13A.4 0.143 w 4,01 2,11 441 362 14411 791 117 106 424 232 106-v 0.600 w 16.80 31.45 41 2 685 1283 0 0 0 0 4A5-2ob 0.560 w 15.68 41.17 22 2 348 914 11 1 174 457 4A5.2ob 0.560 w 15.68 42.07 16 1 256 687 -_ 0 _ 0 0 0 __--_.._....2.55�_1.06._- _ 288288 734 '1 0 0 _0 _.___o C 16C30ml 0.032 - 0.90 128 1312 1312 1176 1679 _195_ 195 175 250 _,989 .27,69 -:0.00 1312 �4597 --__ 0_ .`195 _�13 a-_360--- .___0 71 6 c)AED excursion 1001 197 Envelopeloss(gain 12892 97331 1133 1136 12 a) Infiltration 2725 -746 264 72 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 4 920 2 460 Appliancaslother 0 0 Subtotal(lines 6 to 13) 15617 11399 1397 1668 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 15617 11399 1397 1668 15 Duct loads 1 19% 31% 3030 3556 19% 31% 271 520 Total room load 18647 14955 1668 2188 Air required(clm) 312 8W 28 117 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. f}iF 2020-Nov-1206.42:51 RghtSute®Universal 201919.021RSU08101 Page K1DoamertslWrighfsoftWACITROSKA,BRANSON.np Calc=MJ8 Front Door faces:NW - wrightsoft® Right-M Worksheet Job: Entire House Date: By. QUICK CALCS, INC. 317 ST.LUCIE LANE,FORT PIERCE,FL34946 Phore:772-466.6799 Email:QUICKCALCS ,AOL.COM 1 Room name WIC BATH 1 2 Exposed wall 13.0 it 16.0 It 3 Room height 9.0 ft heatlmol 9.0 ft heaVcool 4 Room dimensions 6D x 7.0 it 6.0 x 10.0 ft 5 Room area 42.0 fE 60.0 f2 Ty Construction U-value Or HTM Area (fF) Load Area Load number (Btuh/It`F) (Btuh/@l or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) H;;7 Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 .W 13A _0.143 n.___.___4.00,_2_19_ _,.E_0 ___0_____o__A._0_____0_0__ 0. -,_. -_ A. 13AAocs 0.143 a 4.00 2-19 0 0 0 0 0 0 0 0 4A5-2ob 0.560 a 15.68 42.07 0 0 0 0 0 0 0 0 4A5-2ob 0.560 a 15.68 29.01 0 0 0 0 0 0 0 0 11 11DO 0.390_e 10.92 10.34 0 0 0 0 0 0 0 0 TE� _ 13A-4as :_ -- --0.. �s-_----4-00 - 219 63 63 _ 252 138 :90 ___90 360 __- 197 � 13AAo s 0.143 w 4.00 2.19 54 54 216 118 0 0 0 0 -G 106-v 0.600 w 16.80 31.45 0 0 0 0 0 0 0 0 4A5.2ob 0.560 w 15.68 41.17 0 0 0 0 0 0 0 0 4A5-2ob 0.560 w 15.68 42-07 F— 0 0 _ 0 —_ 0 _ 0 _ 0 0 — 0 P.. 12C-0sy✓- __.___ 0.091 _ _----2.55 1.06._� 0 _0_......_ .0_._._ s4� 54 —__13$— C 16CS0ml 0.032 - 0.90 128 42 42 38 54 60 60 54 77 7- 6 c)AED excursion -13 -13 Envelope loss/gain 866 297 995 317 12 a) Infiltration 264 72 203 56 b) Room ventilation 0 01 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1130 369 1198 373 Less extemalload 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1130 369 1198 373 15 Ductloads 19% 31% 219 115 19% 31% 232 116 Total room load 1350 484 1431 490 Air required(cfm) 23 26 24 26 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. f� wrigF�tsoR� 2020-Nov-1206:42:51 AftA RightSute®Universal 201919.021RSU08101 Paget K1DoamertslWrightsoftWAC1TROSKA,BRANSON.np Calc=MJ8 Front Door faces:NW -r ►-wrightsoftm Right-M Worksheet Job: Entire House Date: BY QUICK CALCS, INC. 317 ST.LUCIE LANE,FORT PIERCE,FL34946 Phone:772-466-6799 Email:QUICKCALCS u,\OL.COM 1 Room name LMNGROOM BEDROOM#3 2 Exposedvmll 52.0 ft 26.0 ft 3 Room height 9D ft heat/cool 9.0 ft heat/000l 4 Room dimensions I D x 567.0 ft 1 D x 158.0 ft 5 Room area 567.0 iF 158.0 ft Ty Construction U-value Or HTM Area (fl Load Area (i12) Load number (BtuhM2 T) (BWh11lo) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 0 r_._.-,126 e. D26 A5-2ob 0.560 a 4.68 2.07 162 120 480 262 0 0 0 0 4A5-lob 0.560 e. 15.68 42.07 0 0 0 0 0 0 0 0 4A5-2ob 0.560 a 15.68 29.01 22 12 339 628 0 0 0 0 11 11DO 0.390 e: 10.92 10.34 20 20 223 211 0 0 0 0 13kloc 13AAocs 0.143 w 4.00 2-19 162 110 441 241 108 92 367 201 G 10B-v 0.600 w 16.80 31.45 41 2 685 1283 0 0 0 0 II—GO 4A5-20b 0.560 w 15.68 41.17 11 1 174 457 0 0 0 0 4A5-2ob 0.560 w 15.68 42.07 0 0 0 0 16 1 256 687 -0.091 .N -- 2.55 1:06 - 135--___.m_135__. _:344_� 143 C, 16C-30ml 0A32 T^_ 0.90 128 567_ -_567 508 726, 158 158 142 202 -2Z,69.._ ,0.00 __ �._567 52 - r - - -- - - — -- - - ,.71 - - - _ _ 7. -..717 6 c)AED excursion 555 296 Envelope loselgain 4671 4525 1989 1662 12 a) Infiltration 752 206 529 145 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 1 230 Appliances(other 0 0 Subtotal(lines 6 to 13) 5423 4731 2518 2036 Less e)temalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 5423 4731 2518 2036 15 Ductloads 1 19% 31% 1052 1476 19% 31% 489 635 Total room load 6475 6206 3007 2672 Air required(dm) 1 1 108 332 50 143 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. f� wrigtitsoft� 2020-Nov-12 06:42:51 """" "'"- •" Right Sdte®Universal 201919.021 RSUB8101 Page 3 K1DoamertslWrigdsoftWAC1TROSKA,BRANSON.np Calc=MJ8 Front Door faces:NW - -wrightsoft® Right-M Worksheet Job: Entire House Date: By. QUICK CALCS, INC. 317 ST.LUCIE LANE,FORT PIERCE,FL34946 Phone:772-466-6799 Email:QUICKCALCS@AOL.COM 1 Room name BATH#2 BEDROOM#2 2 Bposed wall 6.0 ft 29.0 ft 3 Room height 9.0 It heat/cool 9.0 ft heat/cool 4 Room dimensions 9.0 x 6.0 ft 12.0 x 14.0 it 5 Room area 54.0 ftZ 168.0 fP Ty Construction U-value Or HTM Area (W) Load Area (fl Load number or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gros N/P/S Heat Cool Gross N/P/S Heat Cool - 6 .W_ 1-3A�ocs4.00. _ 219__: _ 54.w_ _W 54__ ._216--�__118--___126._____.__126- ____505 _ a, 276. 13A-4ocs 0.143 a 4.00 2.19 0 0 0 0 108 92 367 201 4A5-2ob 0.560 a 15.68 42.07 0 0 0 0 16 1 256 687 4A5-2ob 0.560 a 15.68 29.01 0 0 0 0 0 0 0 0 11 11DO 0.390 a 10.92 10.34 0 0 0 0 0 0 0 0 W.._.- 13A-0ocs_» _ 0.143:s 4.00.- 219._ ; -0 - -0 _ 0 _ -0- -- 27 - _27 _. - 108 1013-v 0.600 w 4.80 1.19 0 0 0 0 0 0 0 0 10B.v 0.600 w 16.80 31.45 0 0 0 0 0 0 0 0 4A5-2ob 0.560 w 15.68 41.17 0 0 0 0 0 0 0 0 4A5-2ob 0.660 w 15.68 42.07 0 0 0 0 0 0 0 0 -_1.06,- -.---,0 C 16C-30ml 0.032= 0.90 1,28! 54 54_-_48 69-- 1613 168 151 21.5 0.00 _ 51_._.. __6 6 c)AED exarrsion -8 -6 Envelope loss/gain 431 180 2189 1432 12 a) Infiltration 122 33 590 161 b) Room ventilation 0 0 0 0 13 Intemalgains: Occupants@ 230 0 0 1 230 Applianoestother 0 0 Subtotal(lines 6to13) 553 213 2779 1823 Less external load 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 553 213 2779 1823 15 Dudloads 19% 31%1 107 66 19% 31% 539 569 TTotal room load 660 280 3318 2392 Air required(dm) I 11 15 55 128 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -�- wrYgF�tsoft� 2020-Nov-12 06.42:51 Right-Sute®Urtversal 201919.0.21 RSU08101 Page 4 KlDoamertslWrightsoftWAC1TROSKA,BRANSON.np Calc=MJ8 Frort Door faces:NW - -wrightsoft Right-J®Worksheet Job: Entire House Date: By, QUICK CALLS, INC. 317 ST.LUCIE LANE,FORT PIERCE,FL34946 Phone:772.466-6799 Email:QUICKCALCS a@AOL.COM 1 Room name HALL LAUNDRY 2 Bposed wall 0 it 11.0 It 3 Room height 9.0 it heat/cool 9.0 It heat/ood 4 Room dimensions 1.0 x 28.0 ft 8.0 x 5.0 ft 5 Room area 28.0 W 40.0 IF Ty Construction U-value Or HTM Area (fF) Load Area (T) Load number (Btuttr.9 (BWhA') or perimeter (it) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cool 6 .W 13A�o�s_._.� _0:143_._n_-,4.00_.__>.2.19 V�__ 0 __0'M�:_.0 ____0 _0- 13A4ocs 0.143 a 4.06 2.19 0 0 0 0 0 0 0 0 4A5-2ob 0.560 a 15.68 42.07 0 0 0 0 0 0 0 0 4A5-2ob 0.560 a 15.68 29.01 0 0 0 0 0 0 0 0 11 11DO 0.390 a 10.92 10.34 0 0 0 0 0 0 0 0 13A7_41ocs . __ _ 4143 _s--___ADO:_.ry 219, _.-0 W 13A4ocs 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 1013-v 0.600 w 16.80 31.45 0 0 0 0 0 0 0 0 4A5-2ob 0.560 w 15.68 41.17 0 0 0 0 0 0 0 0 4A5-2ob 0.560 w 15.68 42.07 0 0 0 0 0 0 0 0 12C-0sw_u _ 0.091 _�- _2.55 r 1,06----0 ._r Q_._ate_A ._ _.__99--- 99 y _252 C 16C-30ml 0.032 - 0.60 128 28 28 25 36 40 40 36 51 ._27,69.�0,00 28._. __._. p 0------0_ _._..4 6 c)AED excursion -1 -5 Envelope loss(gain 25 35 593 150 12 a) Infiltration 0 0 0 0 b) Roomventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Applianoestother 0 0 subtotal(lines 6 to 13) 25 35 593 150 Less ekemalload 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 25 35 593 150 151 DUdloads 1 19% 31% 5 11 19% 31% 115 47 Total room load 30 45 708 197 Air required(dm) 1 1 2 1 12 11 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. f}t- � 2020-Nov-12 06:42:51 Aft ^ " -'�'-� Pight-SLite@Uriversal20l9l9.021 RSU08101 Page KVoamertMWrighlsoftWAC\TROSKA,BRANSON.np Calc=MJ8 Front Door faces:NW -�- wrightsoft e Duct System Summary o : Entire House By. QUICK CALCS, INC. 317 ST.LUCIE LANE,FORT PIERCE,FL34946 Phorn:772-466-6799 Email:QUICKCALCS@AOL.COM Project • • For. BRANSON TROSKA 7106 BANYAN ST.,FT.PIERCE,FL Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.28 in H2O 0.28 in H2O Available static pressure 0.22 in H2O 0.22 in H2O Supply/return available pressure 0.110/0.110 in H2O 0.110/0.110 in H2O Lowest friction rate 0.080 in/100ft 0.080 in/100ft Actual airflow 312 cfm 800 cfm Total effective length(TEL) 145 ft SupplyDetail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cf n) (dm) FR (in) (in) Mat Ln(ft) Ln(ft) Trunk 13ATE+#2 C 280 11 15 0.080 4.0 Ox0 MFx 30.3 110.0 st2 BATH 1 c 490 24 26 0.080 4.0 Ox 0 MFx 11.4 70.0 BEDROOM#2 c 2392 55 128 0.080 7.0 Ox0 VIFx 35.1 110.0 st2 BEDROOM#3 c 2672 50 143 0.080 7.0 Ox 0 VIFx 31.4 110.0 s12 HALL C 45 1 2 0.080 4.0 Ox0 MFx 0 0 LAUNDRY h 708 12 11 0.080 4.0 Ox0 MFx 3.9 70.0 LIVING ROOM c 2069 36 111 0.080 7.0 Ox 0 VI Fx 23.7 90.0 st1 LIVING ROOM-A c 2069 36 111 0.080 7.0 Ox 0 MFx 26.1 90.0 st1 LIVING ROOM-B c 2069 36 111 0.080 7.0 Ox 0 MFx 24.3 90.0 st1 MASTER BEDROOM c 2188 28 117 0.080 7.0 Ox 0 VIFx 6.6 70.0 WIC c 484 23 26 0.080 4.0 Ox 0 VI Fx 15.9 70.0 Supply Trunk DetailTable Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (dm) (cfm) FR (fpm) (in) (in) Material Trunk st2 PeakAVF 117 286 0.080 524 10.0 0 x 0 VinIFIX st1 st1 PeakAVF 225 618 0.080 787 12.0 0 x 0 VinIFIX Bolddalio values have been manuany ovenidden wrightsof - 2020-Nov-1206:42:51 /9liliP� .w*..v--� RighFSLite@Uriversal20l9l9.021 RSL]08101 Page 1 K\DoamertslwrightsoftwAC\TROSKA,BRANSON.rW Calc=MJ8 Frort Door laces:NW DetailReturn Branch Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (dm) (ft) FR (fpm) (in) (in) Opening(in) Mat Trunk rti1 Ox 0 312 800 0 0 0 0 Ox 0 VIFx Wrightsoft, 2020-Nov-1206:42:51 ^'� .�*•r a .ww—,moo-, RightSute®Uriversa1201919.021 RSLI08101 Paget ACCK ...K1DoamerislWrigHsoftWACITROSKA,BRANSONAp Calc=MJ8 Frort Door faces:NW 2017 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: BRANSON TROSKA Builder Name: CAL BUILDERS Street: 7106 BANYAN ST. Permit Office: ST.LUCIE COUNTY City,State,Zip: FT.PIERCE,FL, Permit Number. Y U Owner: BRANSON TROSKA Jurisdiction: ST.LUCIE COUNTY W Design Location: FL,Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/doorjambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl-space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Concealed When required to be sealed,concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between cover plates and wa,I' a.In addition,inspection of log walls shall be in accordance with the provisions of ICC-400. 11/12/2020 6:43 AM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 1