Loading...
HomeMy WebLinkAboutCurries Installation Insteuctions; AnchoringCURRIES Installation Instructions Anchorinc 1) Rough opening material, by others, must be installed properly to transfer loads to the building structure. 2) Anchoring or loading conditions not shown in these details are not part of this approval. 3) Building walls must be designed to support and sustain loads developed by the door and frame assembly and transfer loads to the building structure. 4) Anchors shall be as listed and spaced as shown in the table below. 5) Anchor embedment to base material shall be beyond wall dressing or stucco. 6) Masonry "T", Pipe Spacer, wire, welded EWA, wood stud, or steel stud anchors required. ANCHOR REQUIREMENT TABLE OPENING ANCHORS W/ 3/8" LAG ANCHORS W/ MAX. MASONRY "T", OR MAX. HEIGHT SCREW, STEEL STUD, 3/8 EXPANSION SPACING WIRE SPACING OR WOOD STUD SHELL ANCHORS 80" - 88" 4 4 22 4 24 90" 5 4 22 4 24 92" - 96" 5 5 22 5 24 CMU BLOCK AND THROAT OF FRAME FILLED WITH 2O00 PSI MORTAR MASONRY WIRE ANCHOR OPERATING RANGE 3" TO 12" RD0446 10/29/2012 EXISTING MASONRY OR POURED CONCRETE 3/8" FLAT HEAD EXPANSION HEAD ANCHOR BOLT 2.50" MIN. 2.50' MIN v • v. ° a• v p. PIPE SPACER ANCHOR O TO SUIT JAMB DEPTH J 1 of 5 3/8" X 5" MIN. WOOD SCREW / LAG BOLT For use with FL8394 a WOOD STUD ANCHOR SLIP -IN STUD ANCHOP #8 X 1" DRYWALL SCREW v EXTERIOR SHEETING WOOD STUD INTERIOR DRYWALL WOOD STUD ANCHOR Hinges 1) Any Steel Door Institute (SDI) Member hinge spacing. 2) Minimum hinge size is 4-1/2" Std. Wt. unless otherwise noted. Locks 1) Any SDI Member lock locations. Glazing 1) Curries Vision Light Kit- Minimum 18 gauge (0.041") when required. 2) Surround Channel — Minimum 20 gauge (0.032") when required. 3) Approved Polycarbonate (1/4" minimum thickness), or GLASSLAM. X 1" DRYWALL SCREW STEEL STUDS #8 X 1" DRYWALL SCREW EXTERIOR SHEETING WOOD STUD INTERIOR DRYWALL Frame 1) Frame heads with faces greater than 2" must be grouted with 2000 psi concrete. 2) Install frames per ANSI A250.11. RD0446 2 of 5 For use with FL8394 10/29/2012 Polycarbonate Glazing Instructions 0.375 1/4" THICK 0.2W POLYCARBONATE SHEET 1/4" THICK POLYCARBONATE SHEET \ 1GL X IN CLOSED EFOAM GLAZING SHIMS GLAZING G TAPE USEDD O ON FIXED AS NEEDED AND REMOVABLE STOPS N6 X 1-1X' OVAL HEAD TEK SCREW Y - I�0II%III =I ' " GLASS STOP GLAZING SHIMS AS NEEDED /6" X 1/2" CLOSED CELL FOAM GLAZING TAPE USED ON FIXED AND REMOVABLE STOPS _#6 X 1-1/4" OVAL HEAD TEK SCREW Curries Type 1 Vision Light Kit Curries Type 3 Vision Light Kit GLASS STOP 1) Before removing the removable stops, check to be. sure there are screws in every hole. Pre- drill holes with a #36 bit where there are screw holes but no screws. Do not remove stops. 2) Using a pencil, mark alignment marks on the removable stops and the door. 3) Unscrew the #6 x 1-1/4" oval head TEK screws from the removable stops and remove the removable stops. Keep the screws. 4) Apply 1/8" x 1/2" closed cell foam glazing tape to the fixed stop. 5) If there is plastic release on the foam glazing tape, pull the plastic release back about 2" from each end of the foam tape. Pull the plastic release around the fixed stop so it can be grasped after placing the polycarbonate on the unexposed foam tape. 6) If there is paper release on the foam glazing tape, remove the paper release before glazing. Spray the exposed foam tape with a mild soap solution immediately before placing the polycarbonate on the exposed foam tape. 7) Place glazing shims, as needed, then set the polycarbonate on the foam glazing tape. 8) Adjust the polycarbonate, as necessary, to center the polycarbonate in the cutout. 9) If the release is plastic, grasp the free end of the plastic release, while holding the polycarbonate to keep it from moving. Then slowly pull the plastic release off the foam tape that was applied to the fixed stop. 10) Apply 1/8" x 1/2" closed cell foam glazing tape to the removable stop. 11) If there is plastic release on the foam glazing tape, pull the plastic release back about 2" from each end of the foam tape. Pull the plastic release around the removable stop so it can be grasped after placing the removable stop on the polycarbonate. 12) If there is paper release on the foam glazing tape, remove the paper. Spray the exposed foam tape with a mild soap solution immediately before placing the removable stops against the polycarbonate. 13) Using the alignment marks, position the removable stops against the polycarbonate. 14) Install and tighten the #6 x 1-1/4" oval head TEK screws in the removable stops. Be careful not to over tighten. 15) If the release is plastic, grasp the free end of the plastic release, and slowly pull the plastic release off the foam tape that was applied to the removable stop. 16) Using the Dow Corning 995 silicone or other high quality silicone, apply a cap bead over the closed cell foam tape on the exterior side of the door vision light kit. RD0446 3 of 5 For use with FL8394 10/29/2012 Glasslam Glazing Instructions 0.625" 0.472" 0.625" GLAZING BY OTHERS 0.472" 1/8" X 1/2" CLOSED CELL FOAM 0.1875" 1 1/8" X 112" CLOSED CELL FOAM 0.1875" LAZING TAPE USED ON FIXED GLAZING TAPE USED ON FIXED 0.097"ND REMOVABLE STOPS 0.097" AND REMOVABLE STOPS LASSLAM (NEBULA GLASS) GLASSLAM (NEBULA GLASS) AMINATED GLASS ASSEMBLY &,,,— LAMINATED GLASS ASSEMBLY #6 X 1-1/4" OVAL HEAD TEK SCREW #6 X 1-1/4" OVAL HEAD TEK SCREW nPET FLAP .500" n PET FLAP LIr Z Ijl GLAZING SHIMS GLASS STOP U GLAZING SHIMS GLASS STOP AS NEEDED AS NEEDED DOW CORNING 995 DOW CORNING 995 STRUCTURAL SILICONE STRUCTURAL SILICONE Curries Type 1 Light Kit Curries Type 3 Vision Light Kit 1) Before removing the removable stops, check to be sure there are screws in every hole. Pre- drill holes with a #36 bit where there are screw holes but no screws. Do not remove stops. 2) Using a pencil, mark alignment marks on the removable stops and the door. 3) Unscrew the #6 x 1-1/4" oval head TEK screws from the removable stops and remove the removable stops. Keep the screws. 4) Apply 1/8" x 1/2" closed cell foam glazing tape to the fixed stop. 5) If there is plastic release on the foam glazing tape, pull the plastic release back about 2" from each end of the foam tape. Pull the plastic release around the fixed stop so it can be grasped after placing the Glasslam on the unexposed foam tape. 6) If there is paper release on the foam glazing tape, remove the paper release before glazing. Spray the exposed foam tape with a mild soap solution immediately before placing the Glasslam on the exposed foam tape. 7) Place glazing shims, as needed, then set the Glasslam on the foam glazing tape. 8) Adjust the Glasslam assembly, as necessary, to center the assembly in the cutout. 9) If the release is plastic, grasp the free end of the plastic release, while holding the Glasslam to keep it from moving. Then slowly pull the plastic release off the foam tape that was applied to the fixed stop. 10) Trim the PET flap so it is flush with the door face. 11) Take a putty knife and insert it between the PET flap and the edge of the cutout in the door. Using the putty knife pull the PET flap away from the cutout in the door. 12) While holding the PET flap back away from the cutout with the putty knife, use a caulking gun to apply Dow Corning 995 silicone between the PET flap and the steel in the cutout of the door. IMPORTANT: Ensure that the Dow Corning 995 silicone fully wets out or covers the PET flap and comes in contact with the steel around the cutout in the door. 13) Slowly move the putty knife around the door ahead of the caulking gun and apply the 995 silicone around the entire cutout in the door. 14) Apply 1/8" x 1/2" closed cell foam glazing tape to the removable stop. RD0446 4 of 5 For use with FL8394 10/29/2012 15) If there is plastic release on the foam glazing tape, pull the plastic release back about 2" from each end of the foam tape. Pull the plastic release around the removable stop so it can be grasped after placing the removable stop on the polycarbonate. 16) If there is paper release on the foam glazing tape, remove the paper. Spray the exposed foam tape with a mild soap solution immediately before placing the removable stops against the Glasslam. 17) Using the alignment marks, position the removable stops against the Glasslam. 18) Install and tighten the #6 x 1-1/4" oval head TEK screws in the removable stops. Be careful not to over tighten. 19) If the release is plastic, grasp the free end of the plastic release, and slowly pull the plastic release off the foam tape that was applied to the removable stop. 20) Using the Dow Corning 995 silicone or other high quality silicone, apply a cap bead over the closed cell foam tape on the exterior side of the door vision light kit. Thresholds and Weather-strip 1.) Thresholds McKinney Products Part Nos. MCK177, MCK181, MCK2005 National Guard PartNos. 803, 804, 896, 8315 Pemko Part Nos. 177, 181, 2005 2.) Weather -Strips McKinney Products Part Nos. MCKS88, MCK303 (Use MCK303 with continuous hinges) National Guard Part Nos. 160, 5050 (Use 160 with continuous hinges) Pemko Part Nos. S88, 303 (Use 303 with continuous hinges) Threshold Installation 12" OC TYP 5.25" TYPICAL THRESHOLD MOUNTING DETAIL NOTE: 1/8" CLEARANCE BETWEEN THE BOTTOM OF THE DOOR AND THE THRESHOLD IS TYPICAL #10 x 1-1/2" WOOD SCREW OR 3/16" X1-1/4" TAP CON lrla�C9LU RD0446 5 of 5 For use with FL8394 10/29/2012