HomeMy WebLinkAboutCurries Installation Insteuctions; AnchoringCURRIES
Installation Instructions
Anchorinc
1) Rough opening material, by others, must be installed properly to transfer loads to the
building structure.
2) Anchoring or loading conditions not shown in these details are not part of this approval.
3) Building walls must be designed to support and sustain loads developed by the door and
frame assembly and transfer loads to the building structure.
4) Anchors shall be as listed and spaced as shown in the table below.
5) Anchor embedment to base material shall be beyond wall dressing or stucco.
6) Masonry "T", Pipe Spacer, wire, welded EWA, wood stud, or steel stud anchors required.
ANCHOR REQUIREMENT
TABLE
OPENING
ANCHORS W/ 3/8" LAG
ANCHORS W/
MAX.
MASONRY
"T", OR
MAX.
HEIGHT
SCREW, STEEL STUD,
3/8 EXPANSION
SPACING
WIRE
SPACING
OR WOOD STUD
SHELL
ANCHORS
80" - 88"
4
4
22
4
24
90"
5
4
22
4
24
92" - 96"
5
5
22
5
24
CMU BLOCK AND THROAT OF FRAME
FILLED WITH 2O00 PSI MORTAR
MASONRY WIRE ANCHOR
OPERATING RANGE 3" TO 12"
RD0446
10/29/2012
EXISTING MASONRY OR
POURED CONCRETE
3/8" FLAT HEAD EXPANSION
HEAD ANCHOR BOLT
2.50" MIN.
2.50' MIN
v
• v.
° a• v
p.
PIPE SPACER ANCHOR
O
TO SUIT
JAMB DEPTH
J
1 of 5
3/8" X 5" MIN.
WOOD SCREW / LAG BOLT
For use with FL8394
a
WOOD STUD ANCHOR
SLIP -IN STUD ANCHOP
#8 X 1" DRYWALL SCREW
v EXTERIOR SHEETING
WOOD STUD
INTERIOR DRYWALL
WOOD STUD ANCHOR
Hinges
1) Any Steel Door Institute (SDI) Member hinge spacing.
2) Minimum hinge size is 4-1/2" Std. Wt. unless otherwise noted.
Locks
1) Any SDI Member lock locations.
Glazing
1) Curries Vision Light Kit- Minimum 18 gauge (0.041") when required.
2) Surround Channel — Minimum 20 gauge (0.032") when required.
3) Approved Polycarbonate (1/4" minimum thickness), or GLASSLAM.
X 1" DRYWALL SCREW
STEEL
STUDS
#8 X 1" DRYWALL SCREW
EXTERIOR SHEETING
WOOD STUD
INTERIOR DRYWALL
Frame
1) Frame heads with faces greater than 2" must be grouted with 2000 psi concrete.
2) Install frames per ANSI A250.11.
RD0446 2 of 5 For use with FL8394
10/29/2012
Polycarbonate Glazing Instructions
0.375
1/4" THICK 0.2W
POLYCARBONATE SHEET
1/4" THICK
POLYCARBONATE SHEET
\ 1GL X IN CLOSED EFOAM
GLAZING SHIMS GLAZING G TAPE USEDD O ON FIXED
AS NEEDED AND REMOVABLE STOPS
N6 X 1-1X' OVAL HEAD TEK SCREW
Y - I�0II%III =I ' "
GLASS STOP
GLAZING SHIMS
AS NEEDED
/6" X 1/2" CLOSED CELL FOAM
GLAZING TAPE USED ON FIXED
AND REMOVABLE STOPS
_#6 X 1-1/4" OVAL HEAD TEK SCREW
Curries Type 1 Vision Light Kit Curries Type 3 Vision Light Kit
GLASS STOP
1) Before removing the removable stops, check to be. sure there are screws in every hole. Pre-
drill holes with a #36 bit where there are screw holes but no screws. Do not remove stops.
2) Using a pencil, mark alignment marks on the removable stops and the door.
3) Unscrew the #6 x 1-1/4" oval head TEK screws from the removable stops and remove the
removable stops. Keep the screws.
4) Apply 1/8" x 1/2" closed cell foam glazing tape to the fixed stop.
5) If there is plastic release on the foam glazing tape, pull the plastic release back about 2"
from each end of the foam tape. Pull the plastic release around the fixed stop so it can be
grasped after placing the polycarbonate on the unexposed foam tape.
6) If there is paper release on the foam glazing tape, remove the paper release before glazing.
Spray the exposed foam tape with a mild soap solution immediately before placing the
polycarbonate on the exposed foam tape.
7) Place glazing shims, as needed, then set the polycarbonate on the foam glazing tape.
8) Adjust the polycarbonate, as necessary, to center the polycarbonate in the cutout.
9) If the release is plastic, grasp the free end of the plastic release, while holding the
polycarbonate to keep it from moving. Then slowly pull the plastic release off the foam
tape that was applied to the fixed stop.
10) Apply 1/8" x 1/2" closed cell foam glazing tape to the removable stop.
11) If there is plastic release on the foam glazing tape, pull the plastic release back about 2"
from each end of the foam tape. Pull the plastic release around the removable stop so it can
be grasped after placing the removable stop on the polycarbonate.
12) If there is paper release on the foam glazing tape, remove the paper. Spray the exposed
foam tape with a mild soap solution immediately before placing the removable stops
against the polycarbonate.
13) Using the alignment marks, position the removable stops against the polycarbonate.
14) Install and tighten the #6 x 1-1/4" oval head TEK screws in the removable stops. Be careful
not to over tighten.
15) If the release is plastic, grasp the free end of the plastic release, and slowly pull the plastic
release off the foam tape that was applied to the removable stop.
16) Using the Dow Corning 995 silicone or other high quality silicone, apply a cap bead over
the closed cell foam tape on the exterior side of the door vision light kit.
RD0446 3 of 5 For use with FL8394
10/29/2012
Glasslam Glazing Instructions
0.625"
0.472"
0.625"
GLAZING BY OTHERS 0.472"
1/8" X 1/2" CLOSED CELL FOAM 0.1875"
1
1/8" X 112" CLOSED CELL FOAM
0.1875"
LAZING TAPE USED ON FIXED
GLAZING TAPE USED ON FIXED
0.097"ND
REMOVABLE STOPS 0.097"
AND REMOVABLE STOPS
LASSLAM (NEBULA GLASS)
GLASSLAM (NEBULA GLASS)
AMINATED GLASS ASSEMBLY
&,,,—
LAMINATED GLASS ASSEMBLY
#6 X 1-1/4" OVAL HEAD TEK SCREW
#6 X 1-1/4" OVAL HEAD TEK SCREW
nPET
FLAP .500" n
PET FLAP
LIr Z Ijl GLAZING SHIMS GLASS STOP
U GLAZING SHIMS GLASS STOP AS NEEDED
AS NEEDED
DOW CORNING 995 DOW CORNING 995
STRUCTURAL SILICONE STRUCTURAL SILICONE
Curries Type 1 Light Kit Curries Type 3 Vision Light Kit
1) Before removing the removable stops, check to be sure there are screws in every hole. Pre-
drill holes with a #36 bit where there are screw holes but no screws. Do not remove stops.
2) Using a pencil, mark alignment marks on the removable stops and the door.
3) Unscrew the #6 x 1-1/4" oval head TEK screws from the removable stops and remove the
removable stops. Keep the screws.
4) Apply 1/8" x 1/2" closed cell foam glazing tape to the fixed stop.
5) If there is plastic release on the foam glazing tape, pull the plastic release back about 2"
from each end of the foam tape. Pull the plastic release around the fixed stop so it can be
grasped after placing the Glasslam on the unexposed foam tape.
6) If there is paper release on the foam glazing tape, remove the paper release before glazing.
Spray the exposed foam tape with a mild soap solution immediately before placing the
Glasslam on the exposed foam tape.
7) Place glazing shims, as needed, then set the Glasslam on the foam glazing tape.
8) Adjust the Glasslam assembly, as necessary, to center the assembly in the cutout.
9) If the release is plastic, grasp the free end of the plastic release, while holding the Glasslam
to keep it from moving. Then slowly pull the plastic release off the foam tape that was
applied to the fixed stop.
10) Trim the PET flap so it is flush with the door face.
11) Take a putty knife and insert it between the PET flap and the edge of the cutout in the door.
Using the putty knife pull the PET flap away from the cutout in the door.
12) While holding the PET flap back away from the cutout with the putty knife, use a caulking
gun to apply Dow Corning 995 silicone between the PET flap and the steel in the cutout of
the door.
IMPORTANT: Ensure that the Dow Corning 995 silicone fully wets out or covers the
PET flap and comes in contact with the steel around the cutout in the
door.
13) Slowly move the putty knife around the door ahead of the caulking gun and apply the 995
silicone around the entire cutout in the door.
14) Apply 1/8" x 1/2" closed cell foam glazing tape to the removable stop.
RD0446 4 of 5 For use with FL8394
10/29/2012
15) If there is plastic release on the foam glazing tape, pull the plastic release back about 2"
from each end of the foam tape. Pull the plastic release around the removable stop so it can
be grasped after placing the removable stop on the polycarbonate.
16) If there is paper release on the foam glazing tape, remove the paper. Spray the exposed
foam tape with a mild soap solution immediately before placing the removable stops
against the Glasslam.
17) Using the alignment marks, position the removable stops against the Glasslam.
18) Install and tighten the #6 x 1-1/4" oval head TEK screws in the removable stops. Be careful
not to over tighten.
19) If the release is plastic, grasp the free end of the plastic release, and slowly pull the plastic
release off the foam tape that was applied to the removable stop.
20) Using the Dow Corning 995 silicone or other high quality silicone, apply a cap bead over
the closed cell foam tape on the exterior side of the door vision light kit.
Thresholds and Weather-strip
1.) Thresholds
McKinney Products Part Nos. MCK177, MCK181, MCK2005
National Guard PartNos. 803, 804, 896, 8315
Pemko Part Nos. 177, 181, 2005
2.) Weather -Strips
McKinney Products Part Nos. MCKS88, MCK303 (Use MCK303 with continuous hinges)
National Guard Part Nos. 160, 5050 (Use 160 with continuous hinges)
Pemko Part Nos. S88, 303 (Use 303 with continuous hinges)
Threshold Installation
12" OC TYP
5.25"
TYPICAL THRESHOLD
MOUNTING DETAIL
NOTE: 1/8" CLEARANCE BETWEEN
THE BOTTOM OF THE DOOR
AND THE THRESHOLD IS
TYPICAL
#10 x 1-1/2" WOOD SCREW
OR
3/16" X1-1/4" TAP CON
lrla�C9LU
RD0446 5 of 5 For use with FL8394
10/29/2012