Evaluation Report; Duro-Last Single Ply Roof Systems
NEMO I etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY REPORT Duro-Last Roofing, Inc. Evaluation Report D9750.05.08-1110 525 Morley Drive Saginaw, MI 48601 (800) 248-0280 FL1559-R13 Date of Issuance: 05/22/2008 Revision 10: 10/17/2018 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 6eh Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Duro-Last Single Ply Roof Systems LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). MEMO ETC, LLC requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO ETC, LLC Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 5, plus a 44-page Appendix. Prepared by: jJJTEn", --- Robert J.M. Nieminen, P.E. '-;F.^.;_�•��= The facsimile seal appearing was authorized by Robert Florida Registration No. 59166, Florida DCA ANE1983 'w� �4" ''����` �i' Nieminen, P.E. on 10/17/2019. This does not serve as an � .;u,,,,,,;,;�.� electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2019 NEMO ETC, LLC ONEMO I etc. ROOFING SYSTEMS EVALUATION: Product Category: Roofing Sub -Category: Single Ply Roof Systems Compliance Statement: Duro-Last Single Ply Roof Systems, as produced by the Duro-Last Roofing, Inc., have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Section 1504.3.1 1504.3.1 1504.7 1507.13.2 1523.6.2 Entity ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST11294) ERD (TST6049) ERD (TST6049) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) NEMO ETC, LLC Certificate of Authorization #32455 Property Wind Wind Impact Physical Properties Wind Examination FM 4474 FM 4474 FM 4474 FM 4474 FM 4474 Physical Properties F M 4474 FM 4474 FM 4474 FM 4474 Physical Properties FM 4474 FM 4474 FM 4474 FM 4474 FM 4474 FM 4474 Physical Properties FM 4474 Tensile Adhesion Tensile Adhesion FM 4470 FM 4470 FM 4470 F M 4470 FM 4470 FM 4470 Standard FM 4474 UL 1897 FM 4470 ASTM D4434 TAS 114 Reference 02733.01.05-1 02737.03.05-1 02743.04.06-R1 02744.05.06 D6760.08.07 02750.02.08 P12200.10.08 02762.03.05-R2 D35320 D42320.08.12 D35210.08.11-R1 D41660SC D43030SC D42390.10.12 D42320.11.12 D41660.11.12-R1 SFS-SC10010.02.16-R1 DL-SC13445.02.17 14325.07.17-3 ICP-SC15630.09.17 ICP-SC16225.09.17 2M4A8.AM 3Y5A6.AM 4D6A4.AM 1X2A7.AM 3005604 3008342 FM 4470 3009502 FM 4470/4474 3012321 FM 4470 30IS444 FM 4470/4474 3014692 FM 4470/4474 3023458 FM 4470/4474 3026128 FM 4470/4474 3026508 FM 4470/4474 3030225 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Duro-Last Single Ply Roof Systems Year 2011 2012 2012 2012 2011 Date 01/21/2005 03/21/2005 06/13/2006 05/17/2006 08/01/2007 02/04/2008 10/14/2008 04/01/2010 04/20/2011 08/31/2012 09/17/2012 09/27/2012 09/28/2012 10/03/2012 11/30/2012 12/12/2012 07/06/2016 02/17/2017 07/20/2017 09/06/2017 09/06/2017 03/05/1987 03/10/1995 08/09/1999 08/09/1999 03/13/2000 10/19/2000 12/21/2000 07/29/2002 07/11/2003 08/05/2003 07/18/2006 08/04/2006 05/03/2007 06/18/2007 Evaluation Report D9750.05.08-1110 FL1559-R13 Revision 10: 10/17/2019 Page 2 of 5 ONEMOjetc. Knfty Examination Reference Date FM Approvals (TST1867) FM 4470/4474 3033314 08/26/2008 FM Approvals (TST1867) FM 4470/4474 3032172 06/12/2009 FM Approvals (TST1867) FM 4470/4474 3041535 06/08/2011 FM Approvals (TST1867) FM 4470/4474 3040346 07/06/2011 FM Approvals (TST1867) FM 4470/4474 3040741 10/17/2011 FM Approvals (TST1867) FM 4470/4474 3047477 10/03/2012 FM Approvals (TST1867) FM 4470/4474 3044466 11/07/2012 FM Approvals (TST1867) FM 4470/4474 3056207 02/09/2016 FM Approvals (TST1867) FM 4470/4474 3059661 09/21/2018 FM Approvals (TST1867) FM 4470/4474 PR451159 05/09/2019 NEMO (TST11294) FM 4474 2a-DL-19-LSWUS-01.A 06/27/2019 PRI(TST5878) FM 4474 DLRI-013-02-01 08/28/2012 PRI(TST5878) FM 4474 DLRI-014-02-01 08/28/2012 PRI(TST5878) FM 4474 DLRI-029-02-01 10/25/2012 PRI(TST5878) FM 4474 DLRI-070-02-01 07/30/2014 PRI(TST5878) FM 4474 DLRI-073-02-02 11/18/2014 PRI(TST5878) ASTM D4434 DLRI-080-02-01 08/03/2016 PRI (TST5878) Small -Scale Criticality DLRI-021-02-01.15 05/09/2019 PRI(TST5878) FM 4474 DLRI-133-02-01 05/09/2019 PRI(TST5878) FM 4474 DLRI-133-02-02 09/06/2019 UL(TST1740) UL1897 TGIK.R10128 03/25/2002 UL, LLC. (QUA9625) Quality Control Service Confirmation 04/12/2019 4. '•••DESCRIPTION: This Evaluation Report covers Duro-Last Single Ply Roof Systems installed in accordance with Duro-Last published installation instructions and the Limitations / Conditions of Use herein. 4.1 Duro-Last roof cover is a nominal 40-mil (1.0 mm), 50-mil (1.3 mm) or 60-mil (1.5-mm) thick thermoplastic (PVC) roof covering having an 18 x 14 polyester fabric reinforcement composed of 840 x 1000 denier threads. 4.2 Duro-Last EV roof cover is a nominal 50-mil (1.3 mm) or 60-mil (1.5-mm) thick thermoplastic (PVC/KEE) roof covering having an 18 x 9 polyester fabric reinforcement with weft insertion, composed of 840 x 1000 denier threads. 4.3 Duro-Tuff roof cover is a nominal 50-mil (1.3 mm) or 60-mil (1.5-mm) thick thermoplastic (PVC) roof covering having an 18 x 9 polyester fabric reinforcement composed of 840 x 1000 denier threads. 4.4 Duro-Fleece roof cover is a nominal 50-mil (1.3 mm) or 60-mil (1.5-mm) thick thermoplastic (PVC) roof covering having an 18 x 9 polyester fabric reinforcement composed of 840 x 1000 denier threads and a polyester fleece backing. 4.5 Duro-Fleece Plus roof cover is a nominal 50-mil (1.3 mm) or 60-mil (1.5-mm) thick thermoplastic (PVC) roof covering having an 18 x 14 polyester fabric reinforcement composed of 840 x 1000 denier threads and a polyester fleece backing. NEMO ETC, LLC Evaluation Report 139750.05.08-1110 Certificate of Authorization #32455 6i" EDITION (2017) FBC NON-HVHZ EVALUATION FL1559-1113 Duro-Last Single Ply Roof Systems Revision 10: 10/17/2019 Page 3 of 5 01 MEMO I etc. 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Refer to a current Approved Roofing Materials Directory for fire ratings of this product. 5.4 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance with FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply. 5.5 The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5.6 For recover installations, the existing roof shall be examined in accordance with FBC 1511. 5.7 For mechanically attached insulation or membrane or strip -bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.8 For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 5.9 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 5.10 For bonded insulation or membrane over existing substrates in a re -roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. 5.11 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 5.12 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with FBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or Roofing Application Standard RAS 111, except the basic wind speed shall be determined from FBC Figure 1609.3(1), 1609.3(2) or 1609.3(3). 5.13 All products in the roof assembly shall have quality assurance in accordance with FAC Rule 61G20-3. For non- Duro-Last components listed within wind uplift rated assemblies in Appendix 1, refer to the Product Approval of the component manufacturer. NEMO ETC, LLC Evaluation Report D9750.05.08-R10 Certificate of Authorization #32455 GTH EDITION (2017) FBC NON-HVHZ EVALUATION FL1559-1113 Duro-Last Single Ply Roof Systems Revision 10: 10/17/2019 Page 4 of 5 ONEMOIetc. 6.1 Duro-Last Single Ply Roof Systems shall be installed in accordance with Duro-Last Roofing, Inc. published installation instructions, subject to the Limitations / Conditions of Use noted herein. 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. 6.2 For mechanically fastened membrane systems (Type D) over profiled steel deck, membrane shall be installed running perpendicular to steel deck flutes. As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. UL, LLC. — QUA9625; (414) 248-6409; karen.buchmann@us.ul.com - THE 44-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT - NEMO ETC, LLC Evaluation Report 139750.05.08-1110 Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION F1.1559-1113 Duro-Last Single Ply Roof Systems Revision 10: 10/17/2019 Page 5 of 5 ONEMOjetc. APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE TABLE DECK APPLICATION TYPE DESCRIPTION PAGE 1A Wood New, Reroof (Tear -Off) or Recover C-1 Mech. Attached Insulation, Bonded Roof Cover 4 1B Wood New, Reroof (Tear -Off) or Recover C-2 Mechanically Attached Insulation, Plate -Bonded Roof Cover 5-6 1C Wood New, Reroof (Tear -Off) or Recover D-1 Prelim. Attached Insulation, Mech. Attached Roof Cover 6-7 2A Steel New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 8 2B Steel or Structural Concrete New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 9 2C Steel or Structural Concrete New, Reroof (Tear -Off) or Recover C-1 Mech. Attached Insulation, Bonded Roof Cover 10-12 2D Steel New, Reroof (Tear -Off) or Recover C-2 Mechanically Attached Insulation, Plate -Bonded Roof Cover 13-17 2E Steel New, Reroof (Tear -Off) or Recover D-1 Prelim. Attached Insulation, Mech. Attached Roof Cover 18-19 2F Steel New or Reroof (Tear -Off) D-2 Thermal Barrier, Vapor Barrier, Prelim. Attached Insulation, Mech. Attached Roof Cover 20 3A Structural Concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 21-24 3B Structural Concrete New, Reroof (Tear -Off) or Recover C-2 Mechanically Attached Insulation, Plate -Bonded Roof Cover 25-28 3C Structural Concrete New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech, Attached Roof Cover 28 3D Structural Concrete New, Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 29 4A Lightweight concrete / steel New or Reroof (Tear -Off) A-1 LWC to Steel Deck, Bonded Insulation, Bonded Roof Cover 30 4B Lightweight concrete / New or Reroof (Tear -Off) A-1 LWC to Structural Concrete Deck, Bonded Insulation, Bonded Roof Cover 30-32 4C Lightweight concrete / steel New or Reroof (Tear -Off) E-2 LWC to Steel Deck, Mechanically Attached Base Sheet, Bonded Roof Cover 33 4D Lightweight concrete / steel New or Reroof (Tear -Off) F LWC to Steel Deck, Bonded Roof Cover 33 4E Lightweight concrete / New or Reroof (Tear -Off) F LWC to Structural Concrete Deck / Bonded Roof Cover 33 5A Cementitious wood fiber Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 34 5B Cementitious wood fiber New, Reroof (Tear -Off) or Recover D-1 Prelim. Attached Insulation, Mech. Attached Roof Cover 34 5C Cementitious wood fiber New, Reroof (Tear -Off) or Recover E-1 Non -insulated, Mech. Attached Roof Cover 34 6A Gypsum Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 35 6B Gypsum Reroof (Tear -Off) or Recover D-1 Prelim. Attached Insulation, Mech. Attached Roof Cover 35 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 36-39 7B Steel Recover C-2 Mechanically Attached Insulation, Plate -Bonded Roof Cover 40-42 7C Steel Recover D-1 Insulated. Mechanicallv Attached Roof Cover 43 7D Cementitious wood fiber Recover E-1 Non -insulated, Mech. Attached Roof Cover 44 7E Various Recover F Non -Insulated, Bonded Roof Cover 44 The following notes apply to the systems outlined herein: The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. Unless otherwise noted, fasteners and stress plates for insulation attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements: ➢ Wood Deck: Duro-Last #14 HD Fasteners and Duro-Last 3-inch Metal Plates. Min. Y.-inch plywood penetration or minimum 1-inch wood plank embedment. ➢ Steel Deck: Duro-Last #14 HD or #15 Extra Heavy Duty Drill Point Fasteners and Duro-Last 3-inch Metal Plates. Minimum %-inch steel penetration, engage the top flute of the steel deck. ➢ Structural Concrete: Duro-Last #14 HD Fasteners, Duro-Last Concrete Screws or Duro-Last Fluted Concrete Nails and Duro-Last 3-inch Metal Plates. Minimum 1-inch embedment. Fasteners installed with a pilot hole in accordance with the fastener manufacturer's published installation instructions. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, fiberboard, perlite and/or gypsum -based insulation board that meets the CIA requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. NEMO ETC, LLC Certificate of Authorization #32455 ©2019 NEMO ETC, LLC 6- EDITION (2017) FBC NON-HVHZ EVALUATION Duro-Last Single Ply Roof Systems; (800) 248-0280 Evaluation Report D9750.05.08-1110 for FL3559-1313 Revision 10: 10/17/2019 Appendix 1, Page 1 of 44 OMEMO I etc. 4. Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type C-2 (plate bonded roof cover) or Type D-1 (mechanically attached roof cover), whereby the membrane fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater type, thickness and strength to the steel and concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5. Preliminary insulation attachment for System Type D-1: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (January 2016) 6. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published instructions. ➢ Ashland Pliodeck: Continuous''/: to Y.-inch wide ribbons, 12-inch o.c. Ribbons for subsequent layer(s) shall be run perpendicular to those for the underlying layer. ➢ Duro-Grip Board -Max: Continuous 3-inch ribbons, 12-inch o.c. ➢ Duro-Grip CR-20: Continuous 2%to 3%:-inch ribbons, 12-inch o.c. ➢ Duro-Grip Insta-Stik: Continuous Y. to 1-inch wide ribbons, 12-inch o.c. ➢ Duro-Grip OlyBond 500: Continuous Y. to 1-inch wide ribbons, 12-inch o.c. using PaceCart, SpotShot or Cansiter. ➢ Duro-Grip WeatherTite One Step Adhesive (WT OSA): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c. ➢ Hot asphalt: Full mopping, 25-30 Ibs/square. ➢ OMG OlyBond Classic: Continuous %-inch ribbons, 12-inch o.c. or full -coverage ➢ Trufast Roofing Adhesive: Continuous % to 1-inch wide ribbons, 12-inch o.c. ➢ Note: When multiple loyers(s) of insulation and/or coverboard are installed in ribbon -applied adhesive, boards shall be staggered from layer -to -foyer. ➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 7. Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations maybe substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to 'increase' the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed fora particular system in the tables, then the thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table: ➢ Duro-Grip CR-20: MDP = -117.5 psf (Min. 1.0-inch thick) ➢ Duro-Grip OlyBond 500: MDP = -315.0 psf (Min. 0.5-inch thick H-Shield, Duro-Guard ISO II-H, ENRGY 3 or Duro-Guard ISO II-G) ➢ Duro-Grip OlyBond 500: MDP = -487.5 psf (Min. 0.5-inch thick ACFoam II or Duro-Guard ISO II -A) ➢ Duro-Grip WeatherTite One Step Adhesive (WT OSA): MDP -157.5 psf (Min. 0.5-inch thick) 8. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft. 9. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 10. For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted. 11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 12. For existing substrates in a bonded recover or re -roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13. For System Type D-1, steel deck applications, the roof membrane shall be run with its length perpendicular to the steel deck flutes. 14. For Structural Concrete Deck or Recover Applications using System Type C-2 (Plate Bonded Roof Cover) or Type D-1 (Mechanically Attached Roof Cover), the insulation is optional. Alternatively, Dens Deck, Dens Deck Prime, SECUROCK Gypsum -Fiber Roof Board, SECUROCK Glass -Mat Roof Board, Duro-Bluer", Duro-Weave'", Duro-Last Geotextile Slip Sheet, Duro-Fold'" or Ultra -Fold" TPM may be used as a separation layer. Board NEMO ETC, LLC Evaluation Report D9750.05.08-1110 for FL1559-R13 . Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 02019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 2 of 44 ONEMOjetc. products should be preliminarily attached prior to roof cover installation. The existing roof system shall be suitable for a recover application. The separator component shall be documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover in Recover applications. 15. Lightweight Insulating Concrete (LWC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced, refer to current LWC Product Approval for specific deck construction and limitations. Unless otherwise noted, for systems where specific LWC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top -coat thickness is 2-inches. For LWC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. For "pre-existent" LWC references, listings were established through testing over lightweight concrete cast using only foaming agent (ASTM C896), water and Portland cement (ASTM C150), with no proprietary additives, in accordance with procedures adopted by Miami -Dade BCCO (FBC CER1592). Unless otherwise noted, use of these listings in new construction or re -roof (tear -off) applications is at the discretion of the Designer of Record and Authority Having Jurisdiction. 16. For adhered membrane systems, side laps shall be minimum 3-inch wide sealed with min.1.5-inch heat weld. Membrane adhesive application rates are as follows: MEMBRANE •.ROOF ADHESIVE COVER I ADHESIVE COMBINATIONS APPLICATION RATE Duro-Last Duro-Last SB I Contact 1.5 gal/sq./surface Duro-Last, Duro-Last EV or Duro-Tuff Duro-Last SB IV Contact 1.67 gal/sq./surface Duro-Last Duro-Last WB I Contact 0.5 gal/sq./surface Duro-Last, Duro-Last EV or Duro-Tuff Duro-Last WB II Substrate only 0.7 gal/sq. Duro-Fleece or Duro-Fleece Plus Duro-Last WB 11 Substrate only 1.0 gal/sq. Duro-Fleece or Duro-Fleece Plus Duro-Fleece Adhesive Substrate only Continuous''/< -inch wide ribbons, 6-inch o.c. Duro-Fleece or Duro-Fleece Plus Duro-Fleece CR-20 Membrane Adhesive Substrate only Splatter -applied, full coverage per Duro-Last instructions Duro-Fleece or Duro-Fleece Plus Trufast Roofing Adhesive Substrate only Continuous'/< to 1-inch wide ribbons, 4-inch o.c., resulting in full -coverage 17. Vapor barrier options for use over structural concrete deck followed by adhesive -applied insulation carry the following Maximum Design Pressure (MDP) limitations. The lesser of the MOP listings below vs. those in Table 3A applies. Option # Primer VAPOR 13ARRIER •• .NCRETE DEcK; FOLLOWED B MDR (psf) Vapor Barrier Insulation Adhesive Type Application VB-1. ASTM D41 Duro-Last Torch Down Vapor Barrier torch -applied Board -Max, 12-inch o.c. -37.5 VB-2. ASTM D41 Duro-Last Torch Down Vapor Barrier torch -applied OlyBond 500, 12-inch o.c. -382.5 VB-3. ASTM D41 Duro-Last Torch Down Vapor Barrier torch -applied Trufast Roofing Adhesive, 12-inch o.c. -180.0 VB-4. ASTM D41 Duro-Last Torch Down Vapor Barrier torch -applied WeatherTite One Step Adhesive, 12-inch o.c. -270.0 VB-5. Duro-Last VB Primer Duro-Last Vapor Barrier self -adhering Board -Max, 12-inch o.c. -37.5 VB-6. Duro-Last VB Primer Duro-Last Vapor Barrier self -adhering OlyBond 500, 12-inch o.c. -187.5 VB-7. Duro-Last VB Primer Duro-Last Vapor Barrier self -adhering Trufast Roofing Adhesive, 12-inch o.c. -390.0 VB-8. Duro-Last VB Primer Duro-Last Vapor Barrier self -adhering WeatherTite One Step Adhesive, 12-inch o.c. -172.5 18. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind pressures. NEMO ETC, LLC Evaluation Report D9750.05.08-R10 for FL3559-R33 Certificate of Authorization #32455 6-EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 3 of 44 NNEMOjetc. TABLE 1A: ....REROOF (TEAR -OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System Top Insulation Layer No Deck (Note 1) Base Insulation Layer Roof Cover (Note 16) MDP (psf) Type Fasteners Attach W 1 Min. 2-inch T&G lumber or min. '/<- (Optional) One or more Min. 0.25-inch Dens Deck or Dens Deck Note 2 1 per 2.67 ft2 Duro-Last / SB 1 or WB II -30.0* inch exterior grade plywood layers, any combination Prime W 2 Min. 2-inch T&G lumber or min. ''/e- (Optional) One or more Min. Yz-inch Dens Deck or Dens Deck Note 2 1 per 3.2 ft2 Duro-Last / SB I or WB II -30.0* inch exterior grade plywood layers, any combination Prime W 3 Min. 2-inch T&G lumber or min. '/<- (Optional) One or more Min. 5/8-inch Dens Deck or Dens Deck Note 2 1 per 4 ft2 Duro-Last / SB I or WB II 30.0* inch exterior grade plywood layers, any combination Prime W 4 Min. 2-inch T&G lumber or min. '/<- (Optional) One or more Min. 1.5-inch ACFoam 11, Duro-Guard Note 2 1 per 2 ft2 Duro-Last / WB 1 -45.0* inch exterior grade plywood layers, any combination ISO II -A Min. 2-inch T&G lumber or min. '/<- (Optional) One or more Min. 1.5-inch ACFoam 11, Duro-Guard W 5. inch exterior grade plywood layers, any combination ISO II -A or ACFoam 111, Duro-Guard 150 Note 2 1 per 4 ft2 Duro-Last / SB 1 -45.0* III -A W 6 Min. 2-inch T&G lumber or min. '/<- (Optional) One or more Min. 1.5-inch ACFoam III, Duro-Guard Note 2 1 per 4 ft2 Duro-Last / WB 1 -45.0* inch exterior grade plywood layers, any combination ISO III -A W 7 Min. 2-inch T&G lumber or min. Y4- (Optional) One or more Min. 0.25-inch Dens Deck or Dens Deck Note 2 1 per 2 ft2 Duro-Last / 513 1 or WB II -45.0* inch exterior grade plywood layers, any combination Prime NEMO ETC, LLC . Certificate of Authorization #32455 ©2019 NEMO ETC, LLC 6- EDITION (2017) FBC NON-HVHZ EVALUATION Duro-Last Single Ply Roof Systems; (800) 248-0280 Evaluation Report D9750.05.08-1110 for FL1559-1113 Revision 10: 10/17/2019 Appendix 1, Page 4 of 44 ONEMOjetc. TABLE 1B: ....REROOF (TEAR -OFF) OR RECOVER PLATE-BONDEDSYSTEM TYPE C-2: MECHANICALLY ATTACHED INSULATION, ROOF COVER System Deck Insulation Layer Attach MDP Roof Cover / Attach No. (Note 1) (Note 14) Fasteners Density (Psf) RHINOBOND INDUCTION WELD: Duro-Last #14 HD Duro-Last (min. 60 mil), Duro-Last EV Min. 19/32-inch (Optional) One or more with RHINOBOND Fasteners 12-inch o.c. in rows spaced 72-inch o.c. positioned atop wood (min. 50 mil) or Duro-Tuff (min. 80-mil) W-8. plywood at max. layers, any combination; Insulation Plate trusses; minimum 0.9-inch fastener embedment into trusses induction welded to RHINOBOND -37.5 24-inch spans preliminarily attached (PVC) Insulation Plate (PVC) using RHINOBOND Installation Tool Duro-Last #14 HD Duro-Last (min. 60 mil), Duro-Last EV Min. 19/32-inch (Optional) One or more with RHINOBOND Fasteners 18-inch o.c. in rows spaced 48-inch o.c. positioned atop wood (min. 50 mil) or Duro-Tuff (min. 80-mil) W-9. plywood at max. layers, any combination; Insulation Plate trusses; minimum 0.9-inch fastener embedment into trusses induction welded to RHINOBOND -37.5 24-inch spans preliminarily attached (PVC; Insulation Plate (PVC) using RHINOBOND Installation Tool Duro-Last #14 HD Duro-Last (min. 60 mil) , Duro-Last EV Min. 19/32-inch (Optional) One or more with RHINOBOND Fasteners 12-inch o.c. in rows spaced 48-inch o.c. positioned atop wood (min. 50 mil) or Duro-Tuff (min. 80-mil) W-10. plywood at max. P Y layers, an combination; Y Y Insulation Plate trusses; minimum 0.9-inch fastener embedment into trusses induction welded to RHINOBOND -52.5 24-inch spans preliminarily attached Insulation Plate (PVC) using RHINOBOND Installation Tool Duro-Last #14 HD Duro-Last (min. 60 mill, Duro-Last EV Min. 19/32-inch (Optional) One or more with RHINOBOND Fasteners 6-inch o.c. in rows spaced 96-inch o.c. positioned atop wood trusses; (min. 50 mil) or Duro-Tuff (min. 80-mil) W-11. plywood at max. layers, any combination; Insulation Plate minimum 0.9-inch fastener embedment into trusses induction welded to RHINOBOND -60.0 24-inch spans preliminarily attached Insulation Plate (PVC) using RHINOBOND Installation Tool 1 per 2.67 ftz �z' zs• za•--za- i,- (12 parts per 4Dur O O OO #14 HD x 8 ft bird; m Duro-Last (min. 40 mil), Duro-Tuff Min. 19/32-inch One or more layers, any with with RHINOBOND Fasteners (min. 50 mil) or Duro-Last EV (min. 50- W-12. plywood at max. combination; min. 1.5- InsulationPlate Insulation Plate engage wood OO o0 OO pop mil) induction welded to RHINOBOND -60.0 24-inch spans inch, min. 16 psi (PVC) trusses, Insulation Plate (PVC) using minimum 0.9- RHINOBOND Installation Tool inch O O O O embedment) NEMO ETC, LLC Evaluation Report D9750.05.08-R10 for FL3559-1113 Certificate of Authorization #32455 6-EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 02019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 5 of 44 ONEMOjetc. System No. Deck (Note 1) TABLE 1B: .. •.. .. RECOVER PLATE-BONDEDSYSTEM TYPE C-2: MECHANICALLY ATTACHED INSULATION, ROOF Insulation Layer Attach (Note 14) Fasteners Density Roof Cover /Attach MDP (psf) 1per2ft2 12•-- 24- 24• 24• 12• (16 parts per 4 O O O O Duro-Last #14 HD x 8 ft brd; Duro-Last (min. 40 mil), Duro-Tuff Min. 19/32-inch One or more layers, any with RHINOBOND Fasteners O O O O (min. 50 mil) or Duro-Last EV (min. 50- W-13. plywood at max. combination; min. 1.5- Insulation Plate engage wood ti mil) induction welded to RHINOBOND -90.0 24-inch spans inch, min. 16 psi (PVC) trusses, O O 0 O Insulation Plate (PVC) using minimum 0.9- N RHINOBOND Installation Tool inch embedment) O O O a 1C: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER INSULATION,TABLE SYSTEM TYPE D-1: PRELIMINARILY ATTACHED ROOF COVER Insulation (Note 14) Roof Cover System Deck (Note 1) Attach MDP No. Type Membrane Fasteners Attach (psf) (Note 5) STANDARD LAP SYSTEMS: Min. 19/32-inch APA 0.5-inch Duro-Guard EPS Fan Fold and/or min. Duro-Last #15 Extra Heavy Duty W-14. rated CDX plywood at 1-inch Duro-Guard 150 II-H, Duro-Guard ISO II- Prelim. Duro-Last, Drill Point Fasteners and Duro- Standard Lao System fastened 12-inch o.c. -30.0 max. 32-inch spans G, Duro-Guard ISO II -A, Duro-Guard ISO III-H or attached min. 40-mil Last Poly -Plates or Duro-Last within 6-inch wide tabs spaced 58-inch o.c. Duro-Guard ISO III -A Cleat Plates Min. 19/32-inch APA 0.5-inch Duro-Guard EPS Fan Fold and/or min. Duro-Last #15 Extra Heavy Duty Standard Lao System fastened 12-inch o.c. W-15. rated CDX plywood at 1-inch Duro-Guard ISO II-H, Duro-Guard ISO II- Prelim. Duro-Last EV, Drill Point Fasteners and Duro- within inch wide laps spaced 54-inch o.c. 30.0 G, Duro-Guard 150 II -A, Duro-Guard ISO III-H or attached min. 50-mil Last Poly -Plates or Duro-Last max. 32-inch spans Duro-Guard I5O III -A Cleat Plates Lap sealed with 1.5-inch heat weld Min. 19/32-inch APA 0.5-inch Duro-Guard EPS Fan Fold and/or min. Duro-Last #15 Extra Heavy Duty Standard Lao System fastened 12-inch o.c. W-16. rated CDX plywood at 1-inch Duro-Guard ISO II-H, Duro-Guard ISO II- Prelim. Duro-Tuff, Drill Point Fasteners Duro-Last within 6-inch wide laps spaced 54-inch o.c. -30.0 max. 32-inch spans G, Duro-Guard ISO II -A, Duro-Guard ISO III-H or attached min. 50-mil Cleat Plates Lap sealed with 1.5-inch heat weld Duro-Guard ISO 111-A Min. 19/32-inch APA 0.5-inch Duro-Guard EPS Fan Fold and/or min. Duro-Last #15 Extra Heavy Duty Standard Lao System fastened 6-inch o.c. W-17. rated CDX plywood at 1-inch Duro-Guard ISO II-H, Duro-Guard ISO 11- Prelim. Duro-Last EV, Drill Point Fasteners and Duro- within 6-inch wide laps spaced inch 37.5 max. 32-inch spans G, Duro-Guard ISO II -A, Duro-Guard ISO III-H or attached min. 50-mil Last Poly -Plates or Duro-Last o.c. Lap sealed with 1.5-inch heaatt weld Duro-Guard ISO III -A Cleat Plates Min. 19/32-inch APA 0.5-inch Duro-Guard EPS Fan Fold and/or min. Duro-Last #15 Extra Heavy Duty Standard Lap System fastened 6-inch o.c. W-18. rated CDX plywood at 1-inch Duro-Guard ISO II-H, Duro-Guard 150 II- Prelim. Duro-Tuff, Drill Point Fasteners and Duro- within 6-inch wide laps spaced 114-inch -37.5 max. 32-inch spans G, Duro-Guard ISO II -A, Duro-Guard ISO III-H or attached min. 50-mil Last Cleat Plates o.c. Lap sealed with 1.5-inch heat weld Duro-Guard ISO III -A NEMO ETC, LLC Evaluation Report D9750.05.08-1110 for FL1559-1113 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 MEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 6 of 44 ONEMOjetc. 1C: WOOD DECKS - NEW CONSTRUCTION, REROOF [TEAR�OFF) OR RECOVER I ATTACHEDTABLE SYSTEM TYPE D-1: PRELIMINARILY ATTACHED INSULATION, MECHANICALLY ROOF COVER Insulation (Note 14) Roof Cover System Deck (Note 1) Attach MDP No. Type Membrane Fasteners Attach (psf) (Note 5) Min. 19/32-inch plywood Prelim. Duro-Last, Duro-Last #15 Extra Heavy Duty Standard Lap System fastened 6-inch o.c. W 19. at max. 24-inch spans (Optional) One or more layers, any combination attached min. 40 mil Drill Point Fasteners and Duro- within 6-inch wide tabs spaced 57-inch o.c. -52.5 Last 2.4-inch Barbed Metal Plate Screws located 2.7-inches from tab edge Min. 19/32-inch APA 0.5-inch Duro-Guard EPS Fan Fold and/or min. Duro-Last #15 Extra Heavy Duty W-20. rated CDX plywood at 1-inch Duro-Guard 150 II-H, Duro-Guard 150 II- Prelim. Duro-Last, Drill Point Fasteners and Duro- Standard Lap System fastened 6-inch o.c. -52.5 max. 32-inch spans G, Duro-Guard ISO II -A, Duro-Guard ISO III-H or attached min. 40-mil Last Poly -Plates or Duro-Last within 6-inch wide tabs spaced 58-inch o.c. Duro-Guard ISO III -A Cleat Plates Min. 19/32-inch APA 0.5-inch Duro-Guard EPS Fan Fold and/or min. Duro-Last #15 Extra Heavy Duty Standard Lap System fastened 6-inch o.c. W-21. rated CDX plywood at 1-inch Duro-Guard ISO II-H, Duro-Guard ISO II- Prelim. Duro-Last EV, Drill Point Fasteners and Duro- within inch wide laps spaced 54 inch o.c. 52.5 max. 32-inch spans G, Duro-Guard ISO II -A, Duro-Guard ISO III-H or attached min. 50-mil Last Poly -Plates or Duro-Last Lap sealed with 1.5-inch heat weld Duro-Guard ISO III -A Cleat Plates Min. 19/32-inch APA 0.5-inch Duro-Guard EP5 Fan Fold and/or min. Duro-Last #15 Extra Heavy Duty Standard Lao System fastened 6-inch o.c. W-22. rated CDX plywood at 1-inch Duro-Guard ISO II-H, Duro-Guard ISO II- Prelim. Duro-Tuff, Drill Point Fasteners and Duro- within 6-inch wide laps spaced 54-inch o.c. -52.5 max. 32-inch spans G, Duro-Guard ISO II -A, Duro-Guard I50 III-H or , attached . min50-mil Last Cleat Plates Lap sealed with 1.5-inch heat weld Duro-Guard ISO III -A DURO-ROOF LAP SYSTEMS: - Min. 19/32-inch plywood Prelim. Duro-Last, Duro-Last #14 HD Fasteners with Duro-Roof Lap System fastened 6-inch o.c. W 23. at max. 24-inch spans (Optional) One or more layers, any combination attached min. 40 mil Duro-Last 3-inch Metal Plates within 6-inch wide tabs spaced 57-inch o.c. -52.5 Tab Sealer 4725 at max. 60 ft2/gal. Nominal 1 x 6 —inch T&G One or more layers, any combination, min. 1.5- Prelim. Duro-Last Duro-Last #15 Extra Heavy Duty Duro-Roof Lao System fastened 6-inch o.c. W-24. board decking attached inch Attached min. 40 mil, Drill Point Fasteners with OMG 2- within 6-inch wide tabs spaced 25-inch o.c. -97.5 per FBC Section 2322.2.2 3/8" Eyehook Plates Tab Sealer 4725 at max. 60 ft2/gal. NEMO ETC, LLC Evaluation Report D9750.05.08-1110 for FL1559-1133 Certificate of Authorization #32455 6- EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 02019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 7 of 44 NNEMOjetc. TABLE 2A: STEEL DECKS - NEW CONSTRUCTION OR REROOF SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System Deck Base Insulation Layer 77 Top Insulation Layer MDP I (Note 1) Type Attach (Notes 6 & 7) Type Attach (Notes 6 & 7) Roof Cover (Note 16) (Psf) BAREBACK MEMBRANE APPLICATIONS: 22 ga., Type B, Min. 1.5-inch Duro-Guard ISO II-H WT OSA, 12-inch o.c. (every- Min. 0.25-inch DEXcell FA Glass Mat WT OSA Duro-Last, Duro-Last EV -75.0 Grade 60 steel other deck flange) Roof Board or Duro-Tuff / SB IV S-2. 22 ga., Type B, Min. 1.5-inch Duro-Guard ISO II-H WT OSA, 12-inch o.c. (every- (Optional) Additional layers) base WT OSA Duro-Last, Duro-Last EV -82.5 Grade 60 steel other deck flange) insulation or Duro-Tuff / SB IV S-3. 22 ga., Type B, Min. 1.5-inch Duro-Guard ISO II-H WT OSA, 12-inch o.c. (every- Min. 0.25-inch DEXcell FA Glass Mat WT OSA Duro-Last, Duro-Last EV -75.0 Grade 60 steel other deck flange) Roof Board or Duro-Tuff/ WB II S-4. 22 ga., Type B, Min. 1.5-inch Duro-Guard I50 II-H WT OSA, 12-inch o.c. (every- (Optional) Additional layer(s) base WT OSA Duro-Last, Duro-Last EV 82.5 Grade 60 steel other deck flange) insulation or Duro-Tuff / WB II DURO-FLEECE OR DURO-FLEECE PLUS MEMBRANE APPLICATIONS: 5-5. 22 ga., Type B, Min. 1.5-inch Duro-Guard 150 II-H WT OSA, 12-inch o.c. (every- Min. 0.25-inch DEXcell FA Glass Mat WT OSA Duro-Fleece CR-20 -75.0 Grade 60 steel other deck flange) Roof Board (splatter applied) S-6. 22 ga., Type B, Min. 1.5-inch Duro-Guard ISO II-H WT OSA, 12-inch o.c. (every- (Optional) Additional layer(s) base WT OSA Duro-Fleece CR-20 82.5 Grade 60 steel other deck flange) g) insulation (splatter applied) S 7' 22 ga., Type B, Min. 1.5-inch Duro-Guard I50 II-H WT OSA, 12-inch o.c. (every- Min. 0.25-inch DEXcell FA Glass Mat WT OSA Duro-Fleece or Duro- 75.0 Grade 60 steel other deck flange) Roof Board Fleece Plus / WB II S 8. 22 ga., Type B, Min. 1.5-inch Duro-Guard ISO II-H WT OSA, 12-inch o.c. (every- (Optional) Additional layer(s) base WT OSA Duro-Fleece or Duro- 82.5 Grade 60 steel other deck flange) insulation Fleece Plus / WB II NEMO ETC, LLC Certificate of Authorization #32455 • ©2019 NEMO ETC, LLC 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Duro-Last Single Ply Roof Systems; (800) 248-0280 Evaluation Report D9750.05.08-R10 for FL1559-R13 Revision 10: 10/17/2019 Appendix 1, Page 8 of 44 ONEMOjetc. TABLE 2B: STEEL OR •.. OR RECOVER SYSTEIVITYPEB: MECHANICALLY ATTACHED.BASE INSULATION, BONDED TOP INSPLATION, BON DED ROOF -COVER System Deck Base Insulation Layer Top Insulation Layer MDP No. (Note 1) Type Fasteners Attach Type Attach (Notes 6 & 7) Roof Cover (Note 16) (psf) BAREBACK MEMBRANE APPLICATIONS: - Min. 22 ga., Type B, Min. 2-inch ACFoam II, Duro-Guard Min. 0.25-inch SECUROCK Hot asphalt or Board -Max, Duro-Last, Duro-Last S-9. Grade 33 steel or 150 II -A, H-Shield, Duro-Guard 150 II- Note 2 1 per 4 ft2 CR-20, Insta-Stik or Trufast EV or Duro-Tuff / SB IV -37.5* structural concrete H, ENRGY 3 or Duro-Guard 150 II-G Gypsum -Fiber Roof Board Roofing Adhesive or WB II Min. 22 ga., Type B, Min. 2-inch ACFoam II, Duro-Guard Min. 0.25-inch SECUROCK Hot asphalt or Board -Max, Duro-Last, Duro-Last S-10. Grade 33 steel or ISO II -A, H-Shield, Duro-Guard ISO II- Note 2 1 per 2.67 ft2 CR-20, Insta-Stik or Trufast EV or Duro-Tuff / 5B IV -45.0* structural concrete H, ENRGY 3 or Duro-Guard ISO II-G Gypsum -Fiber Roof Board Roofing Adhesive or WB II Min. 22 ga., Type B, Min. 2-inch ACFoam 11, Duro-Guard Min. 0.25-inch SECUROCK Hot asphalt or Board -Max, Duro-Last, Duro-Last S-11. Grade 33 steel or 150 II -A, H-Shield, Duro-Guard 150 II- Note 2 1 per 1.33 ft2 CR-20, Insta-Stik or Trufast EV or Duro-Tuff / SB IV -60.0 structural concrete H, ENRGY 3 or Duro-Guard ISO II-G Gypsum -Fiber Roof Board Roofing Adhesive, 6-inch o.c. or WB 11 DURO-FLEECE OR DURO-FLEECE PLUS MEMBRANE APPLICATIONS: - Min. 22 ga., Type B, Min. 2-inch ACFoam II, Duro-Guard Hot asphalt or Board -Max, Duro-Fleece or Duro- 5-12. Grade 33 steel or ISO II -A, H-Shield, Duro-Guard 150 II- Note 2 1 per 4 ft2 Min. 0.25-inch SECUROCK CR-20, Insta-Stik or Trufast Fleece Plus / Duro- -37.5* structural concrete H, ENRGY 3 or Duro-Guard ISO II-G Gypsum -Fiber Roof Board Roofing Adhesive, 6-inch o.c. Fleece CR-20 (splatter applied) or WB II Min. 22 ga., Type B, Min. 2-inch ACFoam II, Duro-Guard Hot asphalt or Board -Max, Duro-Fleece or Duro- S-13. Grade 33 steel or ISO II -A, H-Shield, Duro-Guard ISO 11- Note 2 1 per 2.67 ft2 Min. 0.25-inch SECUROCK CR-20, Insta-Stik or Trufast Fleece Plus / Duro- -45.0* structural concrete H, ENRGY 3 or Duro-Guard ISO II-G Gypsum -Fiber Roof Board Roofing Adhesive, 6-inch o.c. Fleece CR-20 (splatter applied) or WB 11 Min. 22 ga., Type B, Min. 2-inch ACFoam II, Duro-Guard Hot asphalt or Board -Max, Duro-Fleece or Duro- 5-14. Grade 33 steel or ISO II -A, H-Shield, Duro-Guard ISO II- Note 2 1 per 1.33 ft2 Min. 0.25-inch SECUROCK CR-20, Insta-Stik or Trufast Fleece Plus / Duro- -60.0 structural concrete H, ENRGY 3 or Duro-Guard ISO II-G Gypsum -Fiber Roof Board Roofing Adhesive, 6-inch o.c. Fleece CR-20 (splatter applied) or WB II MEMO ETC, LLC Evaluation Report D9750.05.08-1110 for FL1559-R33 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 9 of 44 OMEMO I etc. TABLE 2C: STEEL . • • .. .. RECOVER BONDED ---SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, ROOF COVER System Deck (Note 1) Base Insulation Layer F Top Insulation Layer Roof Cover (Note 16) MDP I Type Fasteners Attach No.I (psf) DURO-LAST MEMBRANE APPLICATIONS: 5-15. Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any Min. 0.25-inch Dens Deck or Dens Deck Prime Note 2 1 pert .67 Duro-Last / SB I or WB II 30.0* steel or structural concrete combination ft Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any 1 per 2.67 Duro-Last, Duro-Last EV S-16. steel or structural concrete combination Min. 0.25-inch Dens Deck Prime Note 2 ft2 or Duro-Tuff / SB IV or -30.0* WB II S-17. Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any Min. A -inch Dens Deck or Dens Deck Prime Note 2 1 per 3.2 Duro-Last / SB I or WB II -30.0* steel or structural concrete combination ft2 Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any 1 per 3.2 Duro-Last, Duro-Last EV 5-18. steel or structural concrete combination Min. %-inch Dens Deck or Dens Deck Prime Note 2 ft2 or Duro-Tuff / SB IV or -30.0* WB II Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any 5-19. steel or structural concrete combination Min. 5/8-inch Dens Deck or Dens Deck Prime Note 2 1 per 4 ft2 Duro-Last / SB I or WB 11 -30.0* Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any Duro-Last, Duro-Last EV 5-20. steel or structural concrete combination Min. 5/8-inch Dens Deck or Dens Deck Prime Note 2 1 per 4 ft 2 or Duro-Tuff / SB IV or -30.0* WB II S-21. Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any Min. 1.0-inch ACFoam 11, Duro-Guard ISO II -A Note 2 steel or structural concrete combination or ACFoam Recover 1 per 2 ft2 Duro-Last / WB II -37.5* Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any Duro-Last, Duro-Last EV S 22 steel or structural concrete combination Min. 1.0-inch ACFoam 11, Duro-Guard ISO 11-A Note 2 1 per 2 ft2 or Duro-Tuff / SB IV or -37.5* WB II Min. 22 a., Type B, Grade 33 g yp (Optional) One or more layers, an ( p ) y y Min. 0.25-inch SECUROCK Gypsum -Fiber Roof yp 1 per 2.67 p Duro-Last, Duro-Last EV 5-23. steel or structural concrete combination Board Note 2 ft2 or Duro-Tuff / SB IV or -37.5* yyg II Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any S 24 steel or structural concrete combination Min. 1.5-inch ACFoam 11, Duro-Guard ISO II -A Note 2 1 per 2 ft2 Duro-Last / WB 1 -45.0* - 5-25. Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any Min. 1.5-inch ACFoam II, Duro-Guard ISO 11-A Note 2 1 per 2 ft2 Duro-Last, Duro-Last EV 45.0* steel or structural concrete combination or Duro-Tuff / SB IV S-26. Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any Min. 2-inch ACFoam II, Duro-Guard ISO II -A or Note 2 ft2 steel or structural concrete combination ACFoam III, Duro-Guard 150 III -A 1 per 4 Duro-Last / SB I 45.0* Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any 5 27 steel or structural concrete combination Min. 2-inch ACFoam III, Duro-Guard 150 III -A Note 2 1 per 4 ft2 Duro-Last / WB 1 -45.0* Min. 22 ga., Type B, Grade 33 One or more layers, any 5 28 steel or structural concrete combination, min. 1.5-inch thick Min. 0.25-inch Invinsa Roof Board Note 2 1 per 2 ft2 Duro-Last / SB IV -45.0* Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any S 29 steel or structural concrete combination Min. 0.25-inch Dens Deck or Dens Deck Prime Note 2 1 per 2 ft2 Duro-Last / SB I or WB II -45.0* NEMO ETC, LLC Evaluation Report D9750.05.08-1110 for F1.3559-1133 Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 10 of 44 ONEMOletc. TABLE 2C: STEEL . • .. .. RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF System Top Insulation Layer MDP Deck (Note 1) Base Insulation Layer Roof Cover (Note 16) No. Type Fasteners Attach (psf) Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any Duro-Last, Duro-Last EV 5-30. Min. 0.25-inch Dens Deck or Dens Deck Prime Note 2 Z 1 per 2 ft or Duro-Tuff / SB IV or -45.0 steel or structural concrete combination WB II 5-31. Min. 22 a., Type B, Grade 33 g yp (Optional) One or more layers, an ( p ) y y Min. 0.25-inch SECUROCK Gypsum -Fiber Roof yp Note 2 1 per 2 ftZ Duro-Last, Duro-Last EV or Duro-Tuff / SB IV or -45.0` steel or structural concrete combination Board WB II 5-32. Min. 22 a., Type B, Grade 33 g yp (Optional) One or more layers, an ( p ) y y Min. 5/8-inch SECUROCK Gypsum -Fiber Roof / yp Note 2 1 per 4 ftZ Duro-Last, Duro-Last EV or Duro-Tuff / SB IV or -45.0• steel or structural concrete combination Board WB II 5-33. Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any Min. 2-inch ACFoam 11, Duro-Guard ISO II -A Dekfast #15 with Dekfast 1 per 2 ftz Duro-Last / 5B 1 -60.0 steel or structural concrete combination Hex Min. 22 ga., Type B, Grade 33 One or more layers, any Min. 0.25-inch SECUROCK Gypsum -Fiber Roof 1 per 1.33 Duro-Last, Duro-Last EV S-34. steel or structural concrete combination, min. 1.5-inch thick Board Note 2 ftZ or Duro-Tuff / SB IV or -67.5 WB II Min. 22 ga., Type B, Grade 33 One or more layers, any Note 2 (#15 Extra Heavy 1 per 1.67 Duro-Last, Duro-Last EV S-35. steel or structural concrete combination, min. 1.5-inch thick Min. 0.25-inch Dens Deck Prime Duty only) ftZ or Duro-Tuff / SB IV -67.5 5-36. Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any Min. 0.25-inch Dens Deck Dekfast #15 with Dekfast 1 per 2 ftZ Duro-Last / SB I or WB II -75.0 steel or structural concrete combination Hex Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any Min. 15/32-inch APA Rated, Grade B-C OMG XHD with OMG 5-37. steel or structural concrete combination plywood Flat Bottom Plates (3- 1 per 2 ftZ Duro-Last / SB I or WB II -90.0 inch square metal) Min. 22 ga., Type B, Grade 33 One or more layers, any Min. 0.5-inch SECUROCK Gypsum Fiber Roof Trufast #12 DP with Duro-Last, Duro-Last EV 5-38. combination, min. 1.5-inch total Trufast 3" Metal Z 1 per 1 ft or Duro-Tuff / SB IV or -97.5 steel thickness Board Insulation Plate WB II DURO-FLEECE OR DURo-FLEECE PLUS MEMBRANE APPLICATIONS: Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any 1 per 2.67 Duro-Fleece or Duro- S-39. steel or structural concrete combination Min. 0.25-inch Dens Deck Prime Note 2 ftZ Fleece Plus / Duro-Fleece -30.0' CR-20 (splatter) or WB II Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any 1 per 3.2 Duro-Fleece or Duro- 5-40. steel or structural concrete combination Min. Y2-inch Dens Deck or Dens Deck Prime Note 2 ftZ Fleece Plus / Duro-Fleece -30.0• CR-20 (splatter) or WB II Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any Duro-Fleece or Duro- 5-41. Min. 5/8-inch Dens Deck or Dens Deck Prime Note 2 Z 1 per 4 ft Fleece Plus / Duro-Fleece R -30.0 steel or structural concrete combination CR-20 (splatter) or WB II Min. 22 a., Type B, Grade 33 g yp (Optional) One or more layers, an ( p ) y y Min. 0.25-inch SECUROCK Gypsum -Fiber Roof yp 1 per 2.67 p Duro-Fleece or Duro- S-42. steel or structural concrete combination Board Note 2 ftZ Fleece Plus / Duro-Fleece -37.5" CR-20 (splatter) or WB II NEMO ETC, LLC Evaluation Report D9750.05.08-R10 for FL3559-R33 Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 11 of 44 ONEMOletc. TABLE 2C: STEEL . • .. .. RECOVER TYPE C-1: MECHANICALLY BONDEDSYSTEM ATTACHED INSULATION, ROOF COVER System Top Insulation Layer MDP Deck (Note 1) Base Insulation Layer Roof Cover (Note 16) No. Type Fasteners Attach (psf) 5-43. Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any Min. 1.0-inch ACFoam II, Duro-Guard 150 II -A Note 2 1 per 2 ftz Duro-Fleece or Duro- -37.5* steel or structural concrete combination Fleece Plus / WB II Min. 1.5-inch ACFoam 11, Duro-Guard 150 II -A, Min. 22 ga., Type B. Grade 33 (Optional) One or more layers, any ACFoam III, Duro-Guard 150 III -A, H-Shield, Duro-Fleece or Duro- 5-44. steel or structural concrete combination Duro-Guard ISO II-H, ENRGY 3, Duro-Guard Note 2 1 per 2 ftz Fleece Plus / WB II -45.0* 150 II-G or 150 95+ GLISO 5-45. Min. 22 a., Type B, Grade 33 g YP (Optional) One or more layers, an ( p ) y y Min. 0.25-inch SECUROCK Gypsum -Fiber Roof Yp Note 2 1 per 2 ftz Duro-Fleece or Duro- Fleece Plus / Duro-Fleece -45.0* steel or structural concrete combination Board CR-20 (splatter) or WB II Min. 22 a., Type B, Grade 33 g Yp (Optional) One or more layers, an ( p ) y y Min. 5/8-inch SECUROCK Gypsum -Fiber Roof / Yp Duro-Fleece or Duro- 5-46. Note 2 1 per 4 ftz Fleece Plus / Duro-Fleece -45.0* steel or structural concrete combination Board CR-20 (splatter) or WB 11 5-47. Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any Min. 0.5-inch Dens Deck Note 2 1 per 2 ftz Duro-Fleece or Duro- -45.0* steel or structural concrete combination Fleece Plus / WB II Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A, z Duro-Fleece or Duro- 5-48. steel or structural concrete combination ACFoam III or 150 95+ GL Note 2 1 per 2 ft Fleece Plus / Duro-Fleece -45.0 Adhesive Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any Duro-Fleece or Duro- 5-49. steel or structural concrete combination Min. 0.5-inch Dens Deck Note 2 1 per 2 ft z Fleece Plus / Duro-Fleece -45.0 Adhesive Min. 22 ga., Type B, Grade 33 One or more layers, any Min. 0.25-inch SECUROCK Gypsum -Fiber Roof 1 per 1.33 Duro-Fleece or Duro- 5-50. steel or structural concrete combination, min. 1.5-inch thick Board Note 2 ftz Fleece Plus / Duro-Fleece -67.5 CR-20 (splatter) or WB 11 Min. 22 ga., Type B, Grade 33 One or more layers, any Note 2 (#15 Extra Heavy 1 per 1.67 Duro-Fleece or Duro- 5-51. steel or structural concrete combination, min. 1.5-inch thick Min. 0.25-inch Dens Deck Prime Duty only) ftz Fleece Plus / Duro-Fleece -67.5 CR-20 (splatter) Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any 1 per 1.33 Duro-Fleece or Duro- S 52. steel or structural concrete combination, min. 1.5-inch thick Min. 0.25-inch Dens Deck Prime Note 2 ftz Fleece Plus / WB 11 67.5 Min. 22 ga., Type B, Grade 33 One or more layers, any Min. 0.5-inch SECUROCK Gypsum Fiber Roof Trufast #12 DP with Duro-Fleece or Duro- 5-53. combination, min. 1.5-inch total Trufast 3" Metal 1 per 1 ftz Fleece Plus / Duro-Fleece -97.5 steel thickness Board I I Insulation Plate CR-20 (splatter) or WB II NEMO ETC, LLC Certificate of Authorization #32455 02019 NEMO ETC, LLC 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Duro-Last Single Ply Roof Systems; (800) 248-0280 Evaluation Report 139750.05.08-1110 for FL1559-1133 Revision 10: 10/17/2019 Appendix 1, Page 12 of 44 ONEMOjetc. TABLE 21): STEEL DECKS - NEW CONSTRUCTION, .. .. RECOVER PLATE-BONDEDSYSTEM TYPE C-2: MECHANICALLY ATTACHED INSULATION, ROOF COVER System Deck Insulation Layer Attach MDP Roof Cover /Attach No. (Note i) (Note 14) Fasteners Density (psf) RHINOBOND INDUCTION WELD: Min. 22 ga., type One or more layers, any Duro-Last #15 Extra Heavy Duty Drill Point 1 per 4 ft z Duro-Last (min. 40-mil), Duro-Tuff (min. 50-mil) or Duro- S-54. B, Grade 33 steel combination Fasteners with RHINOBOND Insulation Plate (2 x 2-ft grid) Last EV (min. 50-mil) induction welded to RHINOBOND -37.5 (PVC) Insulation Plate (PVC) using RHINOBOND Installation Tool Min. 22 ga., type One or more layers, any Duro-Last #15 Extra Heavy Duty Drill Point 1 per 6 ft a Duro-Last (min. 40-mil), Duro-Tuff (min. 50-mil) or Duro- 5-55. B, Grade 33 steel combination Fasteners with RHINOBOND Insulation Plate (24 x 36 inch grid pattern) Last EV (min. 50-mil) induction welded to RHINOBOND -45.0' (PVC) Insulation Plate (PVC) using RHINOBOND Installation Tool Min. 22 ga., type One or more layers, any Duro-Last #15 Extra Heavy Duty Drill Point 1 per 2.29 ftz Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro- 5-56. B Grade 33 steel combination Fasteners with RHINOBOND Insulation Plate (14 parts per 4 x 8 ft board Tuff (min. 80-mil) induction welded to RHINOBOND -45.0 (PVC) in 18 x 18 inch grid pattern) Insulation Plate (PVC) using RHINOBOND Installation Tool One or more layers DURO- 1 per 4 ftz GUARD ISO II -A, DURO-GUARD (8 parts per 4 x 8 ft board) Min. 20 ga., Type ISO II-G, DURO-GUARD ISO II-H, OMG XHD with RHINOBOND Insulation Plate parts spaced 24" o.c. in rows spaced Duro-Last (min. 40-mil), Duro-Tuff (min. 50-mil) or Duro- 5-57. N, Grade 40 steel DURO-GUARD ISO III -A or (PVC) 24"o.c., while maintainingfostener engagement with the topflange of Last EV (min. 50-mil) induction welded to RHINOBOND -52.5 DURO-GUARD ISO III-H• top the Type Ndeck profile. Every -other Insulation Plate (PVC) using RHINOBOND Installation Tool layer min. 1-inch set of two (2) rows is staggered 8- inchesfrom the previous set. Min. 18 ga., type One or more layers, any Duro-Last #15 Extra Heavy Duty Drill Point 12-inch o.-in rows spaced Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro- S-58. B, Grade 33 steel combination, preliminarily Fasteners with RHINOBOND Insulation Plate 60-inch o.c. Tuff (min. 80-mil) induction welded to RHINOBOND -30.0 attached (Note 5) (PVC) Insulation Plate (PVC) using RHINOBOND Installation Tool Min. 18 ga., type One or more layers, any Duro-Last #15 Extra Heavy Duty Drill Point 6-inch o.c. in rows spaced Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro- S-59. B, Grade 33 steel combination, preliminarily Fasteners with RHINOBOND Insulation Plate 120-inch o.c. Tuff (min. 80-mil) induction welded to RHINOBOND -45.0 attached (Note 5) (PVC) Insulation Plate (PVC) using RHINOBOND Installation Tool Min. 18 ga., type One or more layers, any Duro-Last #15 Extra Heavy Duty Drill Point 12-inch o.-in rows spaced Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro- S-60. B, Grade 33 steel combination, preliminarily Fasteners with RHINOBOND Insulation Plate 48inch o.c. Tuff (min. 80-mil) induction welded to RHINOBOND -45.0 attached (Note 5) (PVC) Insulation Plate (PVC) using RHINOBOND Installation Tool Min. ga., type One or more layers, any Duro-Last #15 Extra Heavy Duty Drill Point 6-inch o.c. in rows spaced Duro-Last (min. 40-mil), Duro-Tuff (min. 50-mil) or Duro- S-61. B, Grade 33 steel combination, preliminarily Fasteners with RHINOBOND Insulation Plate 72-inch o.c. Last EV (min. 50-mil) induction welded to RHINOBOND -52.5 attached Note 5 ( ) (PVC) Insulation Plate (PVC) using RHINOBOND Installation Tool Min. ga., type One or more layers, any Duro-Last #15 Extra Heavy Duty Drill Point 6-inch o.c. in rows spaced Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro- S-62. B, Grade 33 steel combination, preliminarily Fasteners with RHINOBOND Insulation Plate 96-inch o.c. Tuff (min. 80-mil) induction welded to RHINOBOND -52.5 attached (Note 5) (PVC) Insulation Plate (PVC) using RHINOBOND Installation Tool Min. ga., type One or more layers, any Duro-Last #15 Extra Heavy Duty Drill Point 6-inch o.c. in rows spaced Duro-Last (min. 40-mil), Duro-Tuff (min. 50-mil) or Duro- S-63. B, Grade 33 steel combination, preliminarily Fasteners with RHINOBOND Insulation Plate 48-inch o.c. Last EV (min. 50-mil) induction welded to RHINOBOND -82.5 attached (Note 5) (PVC) Insulation Plate (PVC) using RHINOBOND Installation Tool Min. ga., type One or more layers, any Duro-Last #15 Extra Heavy Duty Drill Point 6-inch o.c. in rows spaced Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro- S-64. B, Grade 33 steel combination, preliminarily Fasteners with RHINOBOND Insulation Plate 60-inch o.c. Tuff (min. 80-mil) induction welded to RHINOBOND -82.5 attached (Note 5) (PVC) Insulation Plate (PVC) using RHINOBOND Installation Tool NEMO ETC, LLC Evaluation Report D9750.05.08-R10 for FL1559-R33 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 13 of 44 OMEMO I etc. TABLE 2D: STEEL DECKS - NEW CONSTRUCTION, .. OR RECOVER PLATE-BONDEDSYSTEM TYPE C-2: MECHANICALLY ATTACHED INSULATION, ROOF COVER System Deck Insulation Layer Attach Roof Cover Attach MDP Fasteners Density No. (Note 1) (Note 14) (psf) Min. 18 ga., type One or more layers, any Duro-Last #15 Extra Heavy Duty Drill Point 6-inch o.c, in rows spaced Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro- 5-65. B Grade 33 steel combination, preliminarily Fasteners with RHINOBOND Insulation Plate 48-inch o.c. Tuff (min. 80-mil) induction welded to RHINOBOND -90.0 attached (Note 5) (PVC) Insulation Plate (PVC) using RHINOBOND Installation Tool ISOWELD INDUCTION WELD: Min. 22 ga., type One or more layers, any SFS Intec Dekfast DF-#15-PH3 with isoweld° 6 ft2 per fastener Duro-Last (min. 40 mil), Duro-Last EV (min. 50 mil) or Duro- 5-66. B Grade 40 steel combination, min. 1.5-inch Fl-P-6.8-13VC Plates 2 x 3-ft grid, staggered Tuff (min. 50 mil) induction welded to SFS isoweld° Fl-P- -37.5 6.8-PVC Plates with SFS isoweld 3000 stand-up tool Min. 22 ga., type One or more layers, any SFS Intec Dekfast DF-#12-PH3 or DF-#15-PH3 6 ft2 per fastener Duro-Last (min. 40 mil), Duro-Last EV (min. 50 mil) or Duro- S-67. B Grade 80 steel combination, min. 1.5-inch Fastener with isoweld° Fl-P-6.8-PVC Plates 2 x 3-ft grid, staggered Tuff (min. 50 mil) induction welded to SFS isoweld° Fl-P- -37.5 6.8-PVC Plates with 5FS isoweld 3000 stand-up tool Min. 22 ga., type One or more layers, any 5FS Intec Dekfast DF-#15-PH3 with isoweld° 4 ftz per fastener Duro-Last (min. 40 mil), Duro-Last EV (min. 50 mil) or Duro- S-68. B Grade 40 steel combination, min. 1.5-inch F1-P-6.8-PVC Plates 2 x 2-ft grid, staggered Tuff (min. 50 mil) induction welded to SF5 isoweld° F1-P- -52.5 6.8-PVC Plates with SFS isoweld 3000 stand-up tool Min. 22 ga., type One or more layers, any SFS Intec Dekfast DF-#12-PH3 or DF-#15-PH3 4 ft' per fastener Duro-Last (min. 40 mil), Duro-Last EV (min. 50 mil) or Duro- S-69. B, Grade 80 steel combination, min. 1.5-inch Fastener with isoweld° Fl-P-6.8-PVC Plates 2 x 2-ft grid, staggered Tuff (min. 50 mil) induction welded to SFS isoweld° F1-P- -52.5 6.8-PVC Plates with SFS isoweld 3000 stand-up tool Min. 22 ga., type One or more layers, any SFS Intec Dekfast DF-#15-PH3 with isoweld° 3 ft2 per fastener Duro-Last (min. 40 mil), Duro-Last EV (min. 50 mil) or Duro- S-70. B Grade 40 steel combination, min. 1.5-inch F1-P-6.8-PVC Plates 1.5 x 2-ft grid, staggered Tuff (min. 50 mil) induction welded to SFS isoweld°F1-P- -82.5 6.8-PVC Plates with SFS isoweld 3000 stand-up tool Min. 22 ga., type One or more layers, any SF5 Intec Dekfast DF-#12-PH3 or DF-#15-PH3 3 ft2 per fastener Duro-Last (min. 40 mil), Duro-Last EV (min. 50 mil) or Duro- 5-71. B Grade 80 steel combination, min. 1.5-inch Fastener with isoweld° F1-P-6.8-PVC Plates 1.5 x 2-ft grid, staggered Tuff (min. 50 mil) induction welded to SFS isoweld°F1-P- -82.5 6.8-PVC Plates with SF5 isoweld 3000 stand-up tool Min. 22 ga., type One or more layers, any SFS Intec Dekfast DF-#15-PH3 with isoweld° 12-inch o.c. in rows spaced Duro-Last (min. 40 mil), Duro-Last EV (min. 50 mil) or Duro- 5-72. B, Grade 40 steel combination, min. 1.5-inch, Fl-P-6.8-PVC Plates 60-inch o.c. Tuff (min. 50 mil) induction welded to SFS isoweld° F1-P- -45.0 preliminarily attached (Note 5) 6.8-PVC Plates with SFS isoweld° 3000 stand-up tool Min. 22 ga., type One or more layers, any SF5 Inter Dekfast DF-#12l-P- DF-#15tes 12-inch o.-ic. in rows spaced Duro-Last (min. 40 mil), Duro-Last EV (min. 50 mil) or Duro- 5-73. B, Grade 80 steel combination, min. 1.5-inch, Fastener with isoweld® Fl-P-6.8-PVC Plates .8 60-inch o.c. Tuff (min. 50 mil) induction welded to SFS isoweld° F1-P- -45.0 preliminarily attached (Note 5) 6.8-PVC Plates with SF5 isoweld° 3000 stand-up tool Min. 22 ga., type One or more layers, any SFS Intec Dekfast DF-#15-PH3 with isoweld° 6-inch o.c. in rows spaced Duro-Last (min. 40 mil), Duro-Last EV (min. 50 mil) or Duro- S-74. B, Grade 40 steel combination, min. 1.5-inch, Fl-P-6.8-PVC Plates 60-inch o.c. Tuff (min. 50 mil) induction welded to SFS isoweld® Fl-P- -90.0 preliminarily attached (Note 5) 6.8-PVC Plates with SFS isoweld° 3000 stand-up tool Min. 22 ga., type One or more layers, any 5FS Inter Dekfast DF-#12l-P- DF-#15tes 6-inch o.c. in rows spaced Duro-Last (min. 40 mil), Duro-Last EV (min. 50 mil) or Duro- S-75. B, Grade 80 steel combination, min. 1.5-inch, Fastener with isoweld° Fi-P-6.8-PVC Plates .8 60-inch D.C. Tuff (min. 50 mil) induction welded to SFS isoweld® Fl-P- -90.0 preliminarily attached (Note 5) 6.8-PVC Plates with SFS isoweld° 3000 stand-up tool TRUFAST INDUCTION WELD: NEMO ETC, LLC Evaluation Report D9750.05.08-R10 for FL3559-1133 _Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 14 of 44 ONEMOletc. TABLE 21): STEEL DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEM TYPE C-2: MECHANICALLY ATTACHED INSULATION, PLATE -BONDED ROOF COVER System Deck Insulation Layer Attach Roof Cover /Attach MDP No. (Note 1) (Note 14) Fasteners Density (psf) Min. 22 ga., type One or more layers, any 1 per 5.33 ft2 Duro-Last (min. 40 mil), Duro-Last EV (min. 50 mil) or Duro- 5-76. B, Grade 33 steel combination, min. 2-inch Trufast #15 EHD with Trufast PVC IW Plate (6 parts per 4x8 ft board on Tuff (min. 50 mil) induction welded to Trufast PVC IW Plates -45.0' a 24x36-inch pattern) with Trufast Induction Welding Tool and Magnets Min. 2ga., type One or more layers, anye 1 per 4 ft2 Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction S 77 B, Gradd 33 steel combination, min. 2-inch Trufast #15 EHD with Trufast PVC IW Plate (8 parts per 4x8 ft board on welded to Trufast PVC IW Plates with Trufast Induction -52.5 a 24x24-inch pattern) Welding Tool and Magnets Min. 22 ga., type One or more layers, any 1 per 4 ft2 Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro- S 78 B, Grade 33 steel combination, min. 2-inch Trufast #15 EHD with Trufast PVC IW Plate (8 parts per 4x8 ft board on Tuff (min. 60 mil) induction welded to Trufast PVC IW Plates -60.0 a 2424-inch pattern) with Trufast Induction Welding Tool and Magnets Min. 22 ga., type One or more layers, any 1 per 3.2 ft2 Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction 5 79 B, Grade 33 steel combination, min. 2-inch Trufast #15 EHD with Trufast PVC IW Plate (10 parts per 4x8 ft board welded to Trufast PVC IW Plates with Trufast Induction -60.0 on a 24x20-inch pattern) Welding Tool and Magnets Min. 22 ga., type One or more layers, any 1 per 3.2 ft2 Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro- 5-80. B, Grade 33 steel combination, min. 2-inch Trufast #15 EHD with Trufast PVC IW Plate (10 parts per 4x8 ft board Tuff (min. 60 mil) induction welded to Trufast PVC IW Plates -67.5 on a 24x20-inch pattern) with Trufast Induction Welding Tool and Magnets Min. 22 ga., type One or more layers, any 1 per 2.7 ft2 Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction S-81. B, Grade 33 steel combination, min. 2-inch Trufast #15 EHD with Trufast PVC IW Plate (12 parts per 4x8 ft board welded to Trufast PVC IW Plates with Trufast Induction -67.5 per FM LPDS 1-29) Welding Tool and Magnets Min. 22 ga., type One or more layers, any 1 per 2.7 ft2 Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro- S-82. B, Grade 33 steel combination, min. 2-inch Trufast #15 EHD with Trufast PVC IW Plate (12 parts per 4x8 ft board Tuff (min. 60 mil) induction welded to Trufast PVC IW Plates -82.5 per FM LPDS 1-29) with Trufast Induction Welding Tool and Magnets Min. 22 ga., type One or more layers, any 1 per 2 ft2 Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction 5-83. B Grade 33 steel combination, min. 2-inch Trufast #15 EHD with Trufast PVC IW Plate (16 parts per 4x8 ft board welded to Trufast PVC IW Plates with Trufast Induction -90.0 on a 12x24-inch pattern) Welding Tool and Magnets Min. 22 ga., type One or more layers, any 1 per 2 ft2 Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro- S-84. B, Grade 33 steel combination, min. 2-inch Trufast #15 EHD with Trufast PVC IW Plate (16 parts per 4x8 ft board Tuff (min. 60 mil) induction welded to Trufast PVC IW Plates -112.5 on a 12x24-inch pattern) with Trufast Induction Welding Tool and Magnets Min. 22 ga., type One or more layers, any 1 per 1.8 ft2 Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction 5-85. B, Grade 33 steel combination, min. 2-inch Trufast #15 EHD with Trufast PVC IW Plate (18 parts per 4x8 ft board welded to Trufast PVC IW Plates with Trufast Induction -105.0 on an 18x16-inch pattern) Welding Tool and Magnets Min. 22 ga., type One or more layers, any 1 per 1.8 ft2 Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro- S-86. B, Grade 33 steel combination, min. 2-inch Trufast #15 EHD with Trufast PVC IW Plate (18 parts per 4x8 ft board Tuff (min. 60 mil) induction welded to Trufast PVC IW Plates -120.0 on an 18x16-inch pattern) with Trufast Induction Welding Tool and Magnets Min. 22 ga., type One or more layers, any 1 per 1.3 ft2 Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction S-87. B, Grade 33 steel combination, min. 2-inch Trufast #15 EHD with Trufast PVC IW Plate (24 parts per 4x8 ft board welded to Trufast PVC IW Plates with Trufast Induction -135.0 on a 12x16-inch pattern) Welding Tool and Magnets NEMO ETC, LLC Evaluation Report D9750.05.08-R10 for FL1559-R13 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 15 of 44 NNEMOjetc. TABLE 21): STEEL DECKS - NEW CONSTRUCTION, .. on RECOVER PLATE-BONDEDSYSTEM TYPE C-2: MECHANICALLY ATTACHED INSULATION, ROOF System Deck Insulation Layer Attach Roof Cover/ Attach MDP No. (Note 1) (Note 14) Fasteners Density (psf) Min. ga., type One or more layers, anye 1 per 1.3 ft2 Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro- S 88 B, Grade 33 steel combination, min. 2-inch Trufast #15 EHD with Trufast PVC IW Plate (24 parts per 48 ft board Tuff (min. 60 mil) induction welded to Trufast PVC IW Plates -172.5 on a 12x16-inch pattern) with Trufast Induction Welding Tool and Magnets Min. ga., type One or more layers, anye 1 per 1 ft' Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction 5 89 B, Grade 33 steel combination, min. 2-inch Trufast #15 EHD with Trufast PVC IW Plate (32 parts per 4x8 ft board welded to Trufast PVC IW Plates with Trufast Induction -142.5 per FM LPDS 1-29) Welding Tool and Magnets Min. ga., type One or more layers, anye 1 per 1 ft2 Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro- 5-90. B, Grade 33 steel combination, min. 2-inch Trufast #15 EHD with Trufast PVC IW Plate (32 parts per 48 ft board Tuff (min. 60 mil) induction welded to Trufast PVC IW Plates -217.5 per FM LPDS 1-29) with Trufast Induction Welding Tool and Magnets Min. 22 ga., type One or more layers, any 12-inch o.c. in rows spaced Duro-Last (min. 40 mil), Duro-Last EV (min. 50 mil) or Duro- S-91. B Grade 33 steel combination, min. 2-inch, Trufast #15 EHD with Trufast PVC IW Plate 60-inch o.c. Tuff (min. 50 mil) induction welded to Trufast PVC IW Plates -45.0 preliminarily attached with Trufast Induction Welding Tool and Magnets Min. ga., type One or more layers, any 12-inch o.in rows spaced Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction 5 92 B, Grade 33 steel combination, min. 2-inch, Trufast #15 EHD with Trufast PVC IW Plate - 48inch o.c. welded to Trufast PVC IW Plates with Trufast Induction -52.5 preliminarily attached Welding Tool and Magnets Min. 22 ga., type One or more layers, any 12-inch o.c. in rows spaced Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro- 5-93. B Grade 33 steel combination, min. 2-inch, Trufast #15 EHD with Trufast PVC IW Plate 48-inch o.c. Tuff (min. 60 mil) induction welded to Trufast PVC IW Plates -60.0 preliminarily attached with Trufast Induction Welding Tool and Magnets Min. 22 ga., type One or more layers, any 12-inch o.c. in rows spaced Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction 5-94. g Grade 33 steel combination, min. 2-inch Trufast #15 EHD with Trufast PVC IW Plate 36-inch o.c. welded to Trufast PVC IW Plates with Trufast Induction -60.0 Welding Tool and Magnets Min. 22 ga., type One or more layers, any 12-inch o.c. in rows spaced Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro- S-95. B Grade 33 steel combination, min. 2-inch Trufast #15 EHD with Trufast PVC IW Plate 36-inch o.c. Tuff (min. 60 mil) induction welded to Trufast PVC IW Plates -82.5 with Trufast Induction Welding Tool and Magnets Min. 22 ga., type One or more layers, any 6-inch o.c. in rows spaced Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction 5-96. B, Grade 33 steel combination, min. 2-inch, Trufast #15 EHD with Trufast PVC IW Plate 72-inch o.c. welded to Trufast PVC IW Plates with Trufast Induction -67.5 preliminarily attached Welding Tool and Magnets Min. 22 ga., type One or more layers, any 6-inch o.c. in rows spaced Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro- S 97 B, Grade 33 steel combination, min. 2-inch, Trufast #15 EHD with Trufast PVC IW Plate 72-inch o.c. Tuff (min. 60 mil) induction welded to Trufast PVC IW Plates -75.0 preliminarily attached with Trufast Induction Welding Tool and Magnets Min. 22 ga., type One or more layers, any 6-inch o.c. in rows spaced Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction S 98 B, Grade 33 steel combination, min. 2-inch, Trufast #15 EHD with Trufast PVC IW Plate 60-inch o.c. welded to Trufast PVC IW Plates with Trufast Induction -75.0 preliminarily attached Welding Tool and Magnets Min. 22 ga., type One or more layers, any 6-inch o.c. in rows spaced Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro- 5 99 B, Grade 33 steel combination, min. 2-inch, Trufast #15 EHD with Trufast PVC IW Plate 60-inch o.c. Tuff (min. 60 mil) induction welded to Trufast PVC IW Plates -90.0 preliminarily attached with Trufast Induction Welding Tool and Magnets NEMO ETC, LLC Evaluation Report D9750.05.08-1110 for FL1559-1113 Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 16 of 44 ONEMOletc. TABLE 21): STEEL DECKS - NEW CONSTRUCTION, •.. .. RECOVER PLATE-BONDEDSYSTEM TYPE C-2: MECHANICALLY ATTACHED INSULATION, ROOF COVER System Deck Insulation Layer Attach MDP Roof Cover /Attach No. (Note 1) (Note 14) Fasteners' Density (psf) Min. 22 ga., type One or more layers, any 6-inch o.c. in rows spaced Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction S-300. 8, Grade 33 steel combination, min. 2-inch, Trufast #15 EHD with Trufast PVC IW Plate 48-inch o.c. welded to Trufast PVC IW Plates with Trufast Induction -90.0 preliminarily attached Welding Tool and Magnets Min. 22 ga., type One or more layers, any 6-inch o.c. in rows spaced Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro- S-101. B, Grade 33 steel combination, min. 2-inch, Trufast #15 EHD with Trufast PVC IW Plate 48-inch o.c. Tuff (min. 60 mil) induction welded to Trufast PVC IW Plates -112.5 preliminarily attached with Trufast Induction Welding Tool and Magnets Min. 22 ga., type One or more layers, any 6-inch o.c. in rows spaced Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction 5-102. 8 Grade 33 steel combination, min. 2-inch Trufast #15 EHD with Trufast PVC IW Plate 36-inch o.c. welded to Trufast PVC IW Plates with Trufast Induction -112.5 Welding Tool and Magnets Min. 22 ga., type One or more layers, any 6-inch o.c. in rows spaced Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro- 5-103. B, Grade 33 steel combination, min. 2-inch Trufast #15 EHD with Trufast PVC IW Plate 36-inch o.c. Tuff (min. 60 mil) induction welded to Trufast PVC IW Plates -150.0 with Trufast Induction Welding Tool and Magnets NEMO ETC, LLC Evaluation Report D9750.05.08-1110 for FL3559-R13 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 17 of 44 NNEMOjetc. TABLE 2E: STEEL DECKS - NEW CONSTRUCTION, •.. .. RECOVER ATTACHEDSYSTEM TYPE D-1: PRELIMINARILY INSULATION, MECHANICALLY ATTACHED ROOF Insulation (Note 14) Roof Cover System Deck (Note 1) Attach MDP NO. Type Membrane Fasteners Attach (psf) (Note 5) STANDARD LAP SYSTEMS: Min. 22 ga., Type B, 50 One or more layers, any Prelim. Duro-Last EV, Duro-Last #15 Extra Heavy Duty Standard Lao System fastened 18-inch o.c. within 6-inch wide S-104. ksi steel combination, min. 1-inch attach min. 50-mil Drill Point Fastener with Duro- laps spaced 54-inch o.c. Laps sealed with 1.5-inch heat weld. -30.0 Last Poly -Plate Min. 22 ga., Type B, 50 One or more layers, any Prelim. Duro-Last EV, Duro-Last #15 Extra Heavy DutyStandard Lao System fastened 12-inch o.c. within 6-inch wide 5-105. ksi steel combination, min. 1-inch attach min. 50-mil Drill Point Fastener with Duro- laps spaced 54-inch o.c. Laps sealed with 1.5-inch heat weld. -37.5 Last Cleat Plate Min. 22 ga., Type B, One or more layers, any Prelim. Duro-Last, Duro-Last #15 Extra Heavy DutyStandard Lao System fastened 12-inch o.c. within 5.75-inch wide S-106. Grade 33 steel combination, min. 1.5-inch attach min. 40 mil Drill Point Fastener with Duro- tabs spaced 120-inch o.c. -37.5 Last Cleat Plate Min. 18 ga., Type B, One or more layers, any Prelim. Duro-Last, Duro-Last #15 Extra Heavy DutyStandard Lao System fastened 9-inch o.c. within 3-inch wide 5-107. Grade 33 steel combination, min. 1.5-inch attach min. 40 mil Drill Point Fastener with Duro- tabs spaced 60-inch O.C. -45.0 Last Poly -Plate Min. 22 ga., Type B, 50 One or more layers, any Prelim. Duro-Last EV, Duro-Last #15 Extra Heavy DutyStandard Lao System fastened 12-inch o.c. within 6-inch wide 5-108. ksi steel combination, min. 1-inch attach min. 50-mil Drill Point Fastener with Duro- laps spaced 54-inch o.c. Laps sealed with 1.5-inch heat weld. -45.0 Last Poly -Plate Min. 22 ga., Type B, One or more layers, any Prelim. Duro-Last EV, Duro-Last #15 Extra Heavy Duty Standard Lao System fastened 6-inch o.c. within 6-inch wide 5-109. Grade 40 steel combination, min. 1-inch attach min. 50-mil Drill Point Fastener with Duro- laps spaced 114-inch o.c. Laps sealed with 1.5-inch heat weld. 45.0 Last Poly -Plate Min. 22 ga., Type B, One or more layers, any Prelim. Duro-Tuff, Duro-Last #15 Extra Heavy Duty Standard Lao System fastened 12-inch o.c. within 4-inch wide S-110. Grade 33 steel combination, min. 1.5-inch total attach min. 50 mil Drill Point Fasteners with Duro- laps spaced 116-inch o.c. Laps sealed with 1.5-inch heat weld. 45.0 thickness, min. 16-psi top layer Last Cleat Plates Duro-Last #15 Extra Heavy Duty S-111. Min. 22 ga., type B, One or more layers, any Prelim. Duro-Last, Drill Point Fasteners with Duro- Standard Lap System fastened 6-inch o.c. within 3-inch wide Grade 80 steel combination, min. 1.5-inch attach min. 40 mil Last 2.4-inch Barbed Metal tabs spaced 84-inch o.c. 60.0 Plates Min. 22 ga., Type B, 50 One or more layers, any Prelim. Duro-Last EV, Duro-Last #15 Extra Heavy Duty Standard Lao System fastened 6-inch o.c. within 6-inch wide S-112. ksi steel combination, min. 1-inch attach min. 50-mil Drill Point Fastener with Duro- laps spaced 54-inch o.c. Laps sealed with 1.5-inch heat weld. -75.0 Last Cleat Plate DURO-ROOF LAP SYSTEMS: Min. 22 ga., Type B, One or more layers, any Prelim. Duro-Last, Duro-Last #15 Extra Heavy Duty Duro-Roof Lap System fastened 12-inch o.c. within 5.75-inch S-113. Grade 33 steel combination, min. 1.5-inch attach min. 40 mil Drill Point Fastener with Duro- wide tabs spaced 120-inch o.c. Tab Sealer 4725 at max. 60 -45.0 Last Cleat Plate ft2/gal. Min. 22 ga., type B, One or more layers, any Prelim. Duro-Last, Duro-Last #15 Extra Heavy Duty Duro-Roof Lao System fastened 12-inch o.c. within 6-inch wide 5-114. Grade 80 steel combination, min. 1.5-inch attach min. 40 mil Drill Point Fasteners with Duro- tabs spaced 57-inch o.c. Tab Sealer 4725 at max. 60 ft2/gal. -SZ.S Last 3-inch Metal Plates NEMO ETC, LLC Certificate of Authorization #32455 ©2019 NEMO ETC, LLC 6-EDITION (2017) FBC NON-HVHZ EVALUATION Duro-Last Single Ply Roof Systems; (800) 248-0280 Evaluation Report D9750.05.08-R10 for FL1559-R13 Revision 10: 10/17/2019 Appendix 1, Page 18 of 44 ONEMOjetc. TABLE 2E: STEEL DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEMTYPED-1: PRELIMINARILY ATTACHED INSULATION, MECHANICALLY ATTACHED ROOF COVER Insulation (Note 14) Roof Cover System Deck (Note 1) MDP Attach No. Type Membrane Fasteners Attach (psf) (Note 5) Min. 22 ga., type B, One or more layers, any Prelim. Duro-Last, Duro-Last #15 Extra Heavy Duty Duro-Roof Lao System fastened 12-inch o.c. within 5.75-inch 5-115. Drill Point Fastener with Duro- wide tabs spaced 84-inch o.c. Tab Sealer 4725 at max. 60 -52.5 Grade 80 steel combination, min. 1.5-inch attach min. 40 mil Last Cleat Plate ft2/gal. Min. 22 ga., type B, One or more layers, any Prelim. Duro-Last, Duro-Last #15 Extra Heavy Duty Duro-Roof Lao System fastened 12-inch o.c. within 5.75-inch S-116. Drill Point Fastener with Duro- wide tabs spaced 57-inch o.c. Tab Sealer 4725 at max. 60 -67.5 Grade 80 steel combination, min. 1.5-inch attach min. 40 mil Last Cleat Plate ft2/gal. Min. 22 ga., type B, One or more layers, any Prelim. Duro-Last, Duro-Last #15 Extra Heavy Duty Duro-RoofLap System fastened 6-inch o.c. within 3-inch wide S-117. Grade 80 steel combination, min. 1.5-inch attach min. 40 mil Drill Point Fastener with Duro- tabs spaced 60-inch o.c. Tab Sealer 4725 at max. 60 ft2/gal. -67.5 Last Batten Bar Min. 22 ga., type B, One or more layers, any Prelim. Duro-Last, Duro-Last #15 Extra Heavy Duty Duro-RoofLao System fastened 6-inch o.c. within 6-inch wide S-118. Grade 80 steel combination, min. 1.5-inch attach min. 40 mil Drill Point Fasteners with Duro- tabs spaced 120-inch o.c. Tab Sealer 4725 at max. 60 ft2/gal. 82.5 Last 3-inch Metal Plates Min. 22 ga., type B, One or more layers, any Prelim. Duro-Last, Duro-Last #15 Extra Heavy Duty Duro-Roof Lao Svstem fastened 6-inch o.c. within 5.75-inch S-119. Grade 80 steel combination, min. 1.5-inch attach min. 40 mil Drill Point Fastener with Duro- wide tabs spaced 120-inch o.c. Tab Sealer 4725 at max. 60 -82.5 Last Cleat Plate ft2/gal. Min. 22 ga., type B, One or more layers, any Prelim. Duro-Last, Duro-Last #15 Extra Heavy Duty Duro-Roof Lao System fastened 6-inch o.c. within 5.75-inch 5-120. Grade 80 steel combination, min. 1.5-inch attach min. 40 mil Drill Point Fastener with Duro- wide tabs spaced 84-inch o.c. Tab Sealer 4725 at max. 60 -97.5 Last Cleat Plate ft2/gal. Min. 22 ga., type B, One or more layers, any Prelim. Duro-Last, Duro-Last #15 Extra Heavy Duty Duro-Roof Lao System fastened 6-inch o.c. within 5.75-inch S-121. Grade 80 steel combination, min. 1.5-inch attach min. 40 mil Drill Point Fastener with Duro- wide tabs spaced 57-inch o.c. Tab Sealer 4725 at max. 60 -135.0 Last Cleat Plate ft2/gal. Min. 22 ga., type B, One or more layers, any Prelim. Duro-Last, Duro-Last #15 Extra Heavy Duty Duro-Roof Lao System fastened 6-inch o.c. within 6-inch wide S-122. Grade 80 steel combination, min. 1.5-inch attach min. 40 mil Drill Point Fasteners with OMG tabs spaced 25-inch o.c. Tab Sealer 4725 at max. 60 ft2/gal. -142.5 2-3/8" Eyehook Plates NEMO ETC, LLC Evaluation Report D9750.05.08-1110 for F1.3559-1113 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 19 of 44 OMEMO I etc. TABLE 2F: STEEL DECKS - NEW CONSTRUCTION .. REROOF VAPORSYSTEM TYPE D-2: THERMAL BARRIER WITH BARRIER, PRELIMINARILY ATTACHED INSULATION, MECHANICALLY ATTACHED ROOF COVER System Deck Thermal Vapor Insulation Roof Cover MDP No. Note 1 ( ) Barrier Barrier Slip Sheet sf (p ) Base Top Attach Membrane Fasteners Attach (Optional) One or more (Optional if Min. 0.25- layers DURO-GUARD ISO using base Duro-Last #14 Min. 22 ga., inch Dens Duro-Last II -A, DURO-GUARD 150 ll- layer(s) Heavy Duty with Duro-Last Duro-Last #15 Extra Standard Lap Type B, Deck Prime, Vapor G, DURO-GUARD ISO II-H, insulation) Min. 3-inch Metal Geotextile Duro-Last, Heavy Duty Drill Point System fastened 5-123. Grade 40 loose -laid, Barrier, self- DURO-GUARD 150 111-A or 0.5-inch DURO- Platen; 1 per slip sheet, min. 40 mil Fastener with Duro- 12-inch o.c. within -52.5 steel adhered or adhering DURO-GUARD 150 III-H, GUARD EPS 5.3 ft ; 6 parts loose -laid Last Poly -Plate or 3-inch wide tabs mech. DURO-GUARD EPS Type Type II-C or Duro-Last Cleat Plate spaced 60-inch o.c. attached II-C or DURO-GUARD EPS DURO-GUARD per 4x8 ft FGF loose -laid EPS FGF board (Optional) One or more (Optional if Min. 0.25- layers DURO-GUARD ISO using base Duro-Last #14 Standard Lao inch Dens II -A, DURO-GUARD 150 Ik layer(s) Heavy Duty Duro-Last #15 Extra System fastened Min. 22 ga., Deck Prime, Duro-Last G, DURO-GUARD ISO II-H, insulation) Min. with Duro-Last Geotextile Heavy Duty Drill Point 12-inch o.c. within 5-124. Type B, loose -laid, Vapor DURO-GUARD ISO III -A or 0.5-inch DURO- 3-inch Metal slip sheet, Duro-Tuff, Fastener with Duro- 6-inch wide laps -52.5 Grade 40 adhered or Barrier, self- DURO-GUARD ISO III-H, GUARD EPS Plate n; 1 per loose -laid min. 50 mil Last Poly -Plate or spaced h o.c. steel mech. adhering DURO-GUARD EPS Type Type II-C or 5.3 ft ; 6 parts Duro-Last Cleat Plate Side lapss ssealed sealed attached II-C or DURO-GUARD EPS DURO-GUARD per 48 ft with 1.5-inch heat - FGF loose -laid EPS FGF board weld NEMO ETC, LLC Evaluation Report D9750.05.08-1110 for FL1559-1113 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 20 of 44 ONEMOletc. TABLE 3A: STRUCTURAL CONCRETE DECKS � NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER REFER . NOTE 17 FORVAPORBARRIER OPTIONS System Deck Base Insulation Layer Top Insulation Layer MDP No. (Note 1) Type Attach (Notes 6 & 7) Roof Cover (Note 16) (psf) Type Attach (Notes 6 & 7) DURO-LAST MEMBRANE APPLICATIONS: C-1. Min. 2,500 psi (Optional) Min. 1.5-inch ACFoam 11, Duro- Ashland Pliodeck Min. 0.25-inch Dens Deck Ashland Pliodeck Duro-Last / WB I 37.5 structural concrete Guard ISO II -A C 2 Min. 2,500 psi Min. 1.5-inch ACFoam 11, Duro-Guard ISO II -A Ashland Pliodeck (Optional) Additional layers of base Ashland Pliodeck Duro-Last / SB I or WB II-45.0 structural concrete insulation C-3. Min. 2,500 psi Min. 1.5-inch ACFoam 11, Duro-Guard ISO 11-A Ashland Pliodeck (Optional) Additional layers of base Ashland Pliodeck Duro-Last, Duro-Last EV or -45.0 structural concrete insulation Duro-Tuff/ SB IV or WB II C 4 Min. 2,500 psi Min. 1.5-inch ACFoam 11, Duro-Guard ISO II -A Ashland Pliodeck (Optional) Additional layers of base Ashland Pliodeck Duro-Last / WB 1 -82.5 structural concrete insulation C 5 Min. 2,500 psi Min. 2-inch ISO 95+ GL Ashland Pliodeck Min. 0.25-inch SECUROCK Gypsum- Ashland Pliodeck Duro-Last/ WB II -217.5 structural concrete Fiber Roof Board C-6. Min. 2,500 psi Min. 2-inch ISO 95+ GL Ashland Pliodeck Min. 0.25-inch SECUROCK Gypsum- Ashland Pliodeck Duro-Last, Duro-Last EV or -217.5 structural concrete Fiber Roof Board Duro-Tuff / SB IV or WB II Min. Z,500 psi Min. 1.5-inch ACFoam 11, Duro-Guard ISO II -A, Min. 0.25-inch SECUROCK Gypsum- Duro-Last, Duro-Last EV or C 7. structural concrete H-Shield, Duro-Guard 150 11-H, ENRGY 3 or Board -Max Fiber Roof Board Board -Max Duro-Tuff / SB IV or WB 11 -247.5 Duro-Guard ISO II-G C 8 Min. 2,500 psi Min. 0.75-inch Duro-Guard EPS Type IX Board -Max Min. 0.25-inch SECUROCK Gypsum- Board -Max Duro-Last, Duro-Last EV or -247.5 structural concrete Fiber Roof Board Duro-Tuff / SB IV or WB 11 C 9 Min. 2,500 psi Min. 0.75-inch Duro-Guard EPS Type IX Board -Max Min. 0.25-inch SECUROCK Gypsum- Board -Max Duro-Last, Duro-Last EV or -255.0 structural concrete Fiber Roof Board Duro-Tuff / SB IV or WB II Min. 2,500 psi Min. 1.5-inch ACFoam 11, Duro-Guard ISO II -A, Min. 0.25-inch SECUROCK Gypsum- Duro-Last, Duro-Last EV or C-10. structural concrete H-Shield, Duro-Guard ISO 11-H, ENRGY 3 or CR-20 Fiber Roof Board CR-20 Duro-Tuff / SB IV or WB 11 -247.5 Duro-Guard ISO II-G C-11. Min. 2,500 psi Min. 0.75-inch Duro-Guard EPS Type 11, VIII or CR-20 Min. 0.25-inch SECUROCK Gypsum- CR-20 Duro-Last, Duro-Last EV or -247.5 structural concrete IX Fiber Roof Board Duro-Tuff / SB IV or WB II C-12. Min. 2,500 psi Min. 0.75-inch Duro-Guard EPS Type 11, VIII or Min. 0.25-inch SECUROCK Gypsum Duro-Last, Duro-Last EV or structural concrete IX CR-20 Fiber Roof Board CR-20 Duro-Tuff / SB IV or WB II 255.0 Min. 2,500 psi (Optional) Min. 1.5-inch ACFoam 11, Duro- C-13. structural concrete Guard ISO II -A Insta-Stik Min. 0.25-inch Dens Deck Insta-Stik Duro-Last / WB 1 -37.5 C-14. Min. 2,500 psi Min. 1.5-inch ACFoam 11, Duro-Guard ISO 11-A Insta-Stik (Optional) Additional layers of base Insta-Stik Duro-Last / SB I or WB II-45.0 structural concrete insulation C-15. Min. 2,500 psi Min. 1.5-inch ACFoam 11, Duro-Guard ISO II -A Insta-Stik (Optional) Additional layers of base Insta-Stik Duro-Last, Duro-Last EV or -45.0 structural concrete insulation Duro-Tuff/SB IV or WB 11 C-16. Min. 2,500 psi Min. 1.5-inch ACFoam 11, Duro-Guard ISO 11-A Insta-Stik (Optional) Additional layers of base Insta-Stik Duro-Last / WB 1 -82.5 structural concrete insulation NEMO ETC, LLC Evaluation Report D9750.05.08-R10 for FI.1559-1113 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 21 of 44 ONEMOletc. CONCRETETABLE 3A: STRUCTURAL . CONSTRUCTION ...... . SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF REFER . NOTE 17 FOR VAPOR BARRIER OPTIONS System Deck Base Insulation Layer Top Insulation Layer MDP No. (Note 1) Roof Cover (Note 16) (psf) Type Attach (Notes 6 & 7) Type Attach (Notes 6 & 7) Min. 2,500 psi Min. 1.5-inch ACFoam II, Duro-Guard 150 II -A, Min. 0.25-inch SECUROCK Gypsum- Duro-Last, Duro-Last EV or C-17. structural concrete H-Shield, Duro-Guard ISO II-H, ENRGY 3 or Insta-Stik Fiber Roof Board Insta-Stik Duro-Tuff/ SB IV or WB II -247.5 Duro-Guard ISO II-G C 18 Min. 2,500 psi Min. 1.5-inch ACFoam 11, Duro-Guard ISO II -A Hot asphalt (Optional) Additional layers of base Hot asphalt Duro-Last / SB I or WB II -45.0 structural concrete insulation C-19. Min. 2,500 psi Min. 1.5-inch ACFoam 11, Duro-Guard ISO II -A Hot asphalt (Optional) Additional layers of base Hot asphalt Duro-Last, Duro-Last EV or -45.0 structural concrete insulation Duro-Tuff/SB IV or WB II C-20. Min. 2,500 psi Min. 1.5-inch ACFoam II, Duro-Guard ISO 11-A Hot asphalt (Optional) Additional layers of base Hot asphalt Duro-Last / WB 1 -75.0 structural concrete insulation Min. 1.5-inch ACFoam 11, Duro-Guard ISO 11-A, C-21. Min. 2,500 psi H-Shield, Duro-Guard ISO II-H, ENRGY 3 or Hot asphalt Min. 0.25-inch SECUROCK Gypsum- Hot asphalt Duro-Last, Duro-Last EV or 247.5 structural concrete Duro-Guard 150 II-G Fiber Roof Board Duro-Tuff / SB IV or WB 11 C 22 Min. 2,500 psi (Optional) Min. 1.5-inch ACFoam 11, Duro- OlyBond 500 Min. 0.25-inch Dens Deck OlyBond 500 Duro-Last/ WB 1 -37.5 structural concrete Guard ISO II -A C-23. Min. 2,500 psi Min. 1.5-inch ACFoam 11, Duro-Guard ISO 11-A OlyBond 500 (Optional) Additional layers of base OlyBond 500 Duro-Last / SB I or WB II -45.0 structural concrete insulation C-24. Min. 2,500 psi Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A OlyBond 500 (Optional) Additional layers of base OlyBond 500 Duro-Last, Duro-Last EV or 45.0 structural concrete insulation Duro-Tuff/ SB IV or WB 11 C-25. Min. 2,500 psi Min. 1.5-inch ACFoam 11, Duro-Guard 150 11-A OlyBond 500 (Optional) Additional layers of base OlyBond 500 Duro-Last / WB 1 -82.5 structural concrete insulation Min. 2,500 p si Min. 1.5-inch ACFoam 11, Duro-Guard ISO 11-A, Min. 0.25-inch SECUROCK Gypsum- Duro-Last, Duro-Last EV or C-26. structural concrete H-Shield, Duro-Guard ISO 11-H, ENRGY 3 or OlyBond 500 Fiber Roof Board OlyBond 500 Duro-Tuff / SB IV or WB II -247.5 Duro-Guard ISO II-G C 27 Min. 2,500 psi Min. 1.5-inch ACFoam 11, Duro-Guard ISO 11-A, OlyElond Classic, full Min. 0.25-inch SECUROCK Gypsum- OlyBond Classic, full Duro-Last, Duro-Last EV or structural concrete H-Shield, Duro-Guard ISO 11-H coverage Fiber Roof Board coverage Duro-Tuff/ SB IV or WB II 457.5 Min. 2,500 psi (Optional) Min. 1.5-inch ACFoam 11, Duro- Trufast Roofing Trufast Roofing C-28. structural concrete Guard ISO II -A Adhesive Min. 0.25-inch Dens Deck Adhesive Duro-Last / WB 1 -37.5 C 29 Min. 2,500 psi Min. 1.5-inch ACFoam 11, Duro-Guard ISO 11-A Trufast Roofing (Optional) Additional layers of base Trufast Roofing Duro-Last / SB I or WB 11 -45.0 structural concrete Adhesive insulation Adhesive C-30. Min. 2,500 psi Min. 1.5-inch ACFoam 11, Duro-Guard ISO II -A Trufast Roofing (Optional) Additional layers of base Trufast Roofing Duro-Last / WB I 82.5 structural concrete Adhesive insulation Adhesive DURO-FLEECE OR DURO-FLEECE PLUS MEMBRANE APPLICATIONS: C-31. Min. 2,500 psi Min. 1.5-inch ACFoam I1, Duro-Guard 150 II -A Ashland Pliodeck (Optional) Additional layers of base Ashland Pliodeck Duro-Fleece or Duro-Fleece 45.0 structural concrete insulation Plus / WB II C-32. Min. 2,500 psi Min. 2-inch ISO 95+ GL Ashland Pliodeck Min. 0.25-inch SECUROCK Gypsum- Ashland Pliodeck Duro-Fleece or Duro-Fleece -217.5 structural concrete Fiber Roof Board Plus / WB 11 NEMO ETC, LLC Certificate of Authorization #32455 ©2019 NEMO ETC, LLC 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Duro-Last Single Ply Roof Systems; (800) 248-0280 Evaluation Report D9750.05.08-1310 for FL1559-R13 Revision 10: 10/17/2019 Appendix 1, Page 22 of 44 ONEMOjetc. TABLE 3A: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION REROOF (TEAR -OFF) SYSTEM TYPE A-1: BONDED BONDED ROOF COVER REFER . ..VAPOR OPTIONS System Deck Base Insulation Layer Top Insulation Layer MDP Roof Cover (Note 16) Type Attach (Notes 6 & 7) Type Attach (Notes 6 & 7) No. (Note 1) (psf) Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A, Duro-Fleece or Duro-Fleece C-33. Min. 2,500 psi H-Shield, Duro-Guard 150 II-H, ENRGY 3 or Board -Max Min. 0.25-inch SECUROCK Gypsum- Board -Max Plus / Duro-Fleece CR-20 -247.5 structural concrete Fiber Roof Board Duro-Guard ISO II-G (splatter) or WB II Duro-Fleece or Duro-Fleece C-34. Min. 2,500 psi Min. 0.75-inch Duro-Guard EPS Type IX Board -Max Min. 0.25-inch SECUROCK Gypsum- Board -Max Plus / Duro-Fleece CR-20 -247.5 structural concrete Fiber Roof Board (splatter) or WB II Min. 2,500 psi Min. 0.25-inch SECUROCK Gypsum- Duro-Fleece or Duro-Fleece C-35. Min. 0.75-inch Duro-Guard EPS Type IX Board -Max Board -Max Plus / Duro-Fleece CR-20 -255.0 structural concrete Fiber Roof Board (splatter) or WB II Min. 1.5-inch ACFoam 11, Duro-Guard ISO II -A, Duro-Fleece or Duro-Fleece C-36. Min. 2,500 psi H-Shield, Duro-Guard ISO II-H, ENRGY 3 or CR-20 Min. 0.25-inch SECUROCK Gypsum- CR-20 Plus / Duro-Fleece CR-20 -247.5 structural concrete Fiber Roof Board Duro-Guard ISO II-G (splatter) or WB II Min. 2,500 psi Min. 0.75-inch Duro-Guard EPS Type II, VIII or Min. 0.25-inch SECUROCK Gypsum- Duro-Fleece or Duro-Fleece C-37. structural concrete IX CR-20 Fiber Roof Board CR-20 Plus / Duro-Fleece CR-20 -247.5 (splatter) or WB II Min. 2,500 psi Min. 0.75-inch Duro-Guard EPS Type 11, VIII or Min. 0.25-inch SECUROCK Gypsum- Duro-Fleece or Duro-Fleece C-38. structural concrete IX CR-20 Fiber Roof Board CR-20 Plus / Duro-Fleece CR-20 -255.0 (splatter) or WB II C-39. Min. 2,500 psi Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A Insta-Stik (Optional) Additional layers of base Insta-Stik Duro-Fleece or Duro-Fleece -45.0 structural concrete insulation Plus / WB 11 Min. 1.5-inch ACFoam 11, Duro-Guard ISO II -A, Duro-Fleece or Duro-Fleece C-40. Min. 2,500 psi H-Shield, Duro-Guard ISO II-H, ENRGY 3 or Insta-Stik Min. 0.25-inch SECUROCK Gypsum- Insta-Stik Plus / Duro-Fleece CR-20 -247.5 structural concrete Duro-Guard ISO 11-G Fiber Roof Board (splatter) or WB 11 C-41. Min. 2,500 psi Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A Hot asphalt (Optional) Additional layers of base Hot asphalt Duro-Fleece or Duro-Fleece -45.0 structural concrete insulation Plus / WB II Min. 1.5-inch ACFoam 11, Duro-Guard ISO 11-A, Duro-Fleece or Duro-Fleece C 42. Min. 2,500 psi H-Shield, Duro-Guard ISO II-H, ENRGY 3 or Hot asphalt Min. 0.25-inch SECUROCK Gypsum- Hot asphalt Plus / Duro-Fleece CR-20 -247.5 structural concrete Duro-Guard ISO 11-G Fiber Roof Board (splatter) or WB II C-43. Min. 2,500 psi Min. 1.5-inch ACFoam 11, Duro-Guard ISO II -A OlyBond 500 (Optional) Additional layers of base OlyBond 500 Duro-Fleece or Duro-Fleece -45.0 structural concrete insulation Plus / WB II Min. 1.5-inch ACFoam 11, Duro-Guard ISO II -A, Duro-Fleece or Duro-Fleece C-44, Min. 2,500 psi H-Shield, Duro-Guard ISO 11-H, ENRGY 3 or OlyBond 500 Min, 0.25-inch SECUROCK Gypsum- OlyBond 500 Plus / Duro-Fleece CR-20 -247.5 structural concrete Fiber Roof Board Duro-Guard ISO II-G (splatter) or WB II Min. 2,psi 500 p Min. 1.5-inch ACFoam 11, Duro-Guard ISO 11-A, OlyBond Classic, full Y Min. 0.25-inch SECUROCK G ypsum- OlyBond Classic, full Duro-Fleece or Duro-Fleece C-45. structural concrete H-Shield, Duro-Guard ISO II-H coverage Fiber Roof Board coverage plus /Duro-Fleece CR-20 -457.5 (splatter) or WB II NEMO ETC, LLC Evaluation Report D9750.05.O8-R10 for F1.3559-1133 Certificate of Authorization N32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 23 of 44 ONEMOjetc. TABLE 3A: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER REFER To NOTE 17 ..VAPORBARRIER OPTIONS System Deck Base Insulation Layer Top Insulation Layer MDP No. (Note 1) Roof Cover (Note 16) (psf) Type Attach (Notes 6 & 7) Type Attach (Notes 6 & 7) Min. 2,500 psi Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A, Trufast Roofing Min. 0.5-inch Duro-Guard I50 HD -A or Trufast Roofing Duro-Fleece or Duro-Fleece C-46. structural concrete ENRGY 3 CGF, Duro-Guard 150 III-G, H-Shield Adhesive Duro-Guard ISO HD-H Adhesive Plus /Trufast Roofing -165.0 CG, Duro-Guard ISO III-H Adhesive, ribbons 4" o.c. Min. 0.25-inch Dens Deck, Dens Deck Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A, Prime, DEXcell FA Glass Mat Roof Duro-Fleece or Duro-Fleece C 47. Min. 2,500 psi ENRGY 3 CGF, Duro-Guard ISO III-G, H-Shield Trufast Roofing Board, SECUROCK Gypsum -Fiber Roof Trufast Roofing Plus / Trufast Roofing 195.0 structural concrete CG, Duro-Guard ISO III-H Adhesive Board or SECUROCK Glass -Mat Roof Adhesive Adhesive, ribbons 4" o.c. Board or min. 7/16" DEXcell Cement Roof Board Min. 2,500 psi Min. 1.5-inch ACFoam 11, Duro-Guard ISO II -A, Trufast Roofing (Optional) Additional layers of base Trufast Roofing Duro-Fleece or Duro-Fleece C-48. structural concrete ENRGY 3 CGF, Duro-Guard 150 III-G, H-Shield Adhesive insulation Adhesive Plus /Trufast Roofing -345.0 CG, Duro-Guard ISO 111-H IAdhesive, ribbons 4" o.c. NEMO ETC, LLC Certificate of Authorization #32455 ©2019 NEMO ETC, LLC 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Duro-Last Single Ply Roof Systems; (800) 248-0280 Evaluation Report D9750.05.08-R10 for FL1559-1113 Revision 10: 10/17/2019 Appendix 1, Page 24 of 44 ONEM01letc. TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, • .. .. RECOVER PLATE-BONDEDSYSTEM TYPE C-2: MECHANICALLY ATTACHED INSULATION, ROOF COVER System Deck Insulation Layer Attach MDP Roof Cover /Attach No. (Note 1) (Note 14) Fasteners Density (psf) RHINOBOND INDUCTION WELD: Min. 2,500 psi One or more layers, any Duro-Last #14 HD with RHINOBOND 1 per 2.67 ft' Duro-Last (min. 40-mil), Duro-Tuff (min. 50-mil) or Duro-Last EV C-49. structural concrete combination Insulation Plate (PVC) (12 parts per 4 x 8 ft board) (min. 50-mil) induction welded to RHINOBOND Insulation Plate -52.5 (PVC) using RHINOBOND Installation Tool Min. 2,500 psi One or more layers, any Duro-Last #14 HD with RHINOBOND 12-inch o.c. in rows spaced Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro-Tuff C-50. structural concrete combination, preliminarily Insulation Plate (PVC) 60-inch o.c. (min. 80-mil) induction welded to RHINOBOND Insulation Plate -37.5 attached (Note 5) (PVC) using RHINOBOND Installation Tool Min. 2,500 psi One or more layers, any Duro-Last #14 HD with RHINOBOND 12-inch o.c. in rows spaced Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro-Tuff C-51. structural concrete combination, preliminarily Insulation Plate (PVC) 48-inch o.c. (min. 80-mil) induction welded to RHINOBOND Insulation Plate -37.5 attached (Nate 5) (PVC) using RHINOBOND Installation Tool Min. , 500 psi 2 One or more layers, any Duro-Last #14 HD with RHINOBOND 6-inch o.. in rows spaced c Duro-Last (min. 40-mil), Duro-Tuff (min. 50-mil) or Duro-Last EV C-52. structural concrete combination, preliminarilyNote Insulation Plate (PVC) .. 60-inch oc (min. 50-mil) induction welded to RHINOBOND Insulation Plate -45.0 attached 5 ( ) (PVC) using RHINOBOND Installation Tool Min. 2,500 psi One or more layers, any Duro-Last #14 HD with RHINOBOND 6-inch o.c. in rows spaced Duro-Last (min. 40-mil), Duro-Tuff (min. 50-mil) or Duro-Last EV C-53. structural concrete combination, preliminarily Insulation Plate (PVC) 48-inch o.c. (min. 50-mil) induction welded to RHINOBOND Insulation Plate -52.5 attached (Note 5) (PVC) using RHINOBOND Installation Tool ISOWELD INDUCTION WELD: Min. psi One or more layers, any SFS Intec Dekfast DF-#14-PH3 or DF- z 6 ft per fastener Duro-Last (min. 40 mil), Duro-Last EV (min. 50 mil) or Duro-Tuff C-54. U structural concrete structural combination, min. 1.5-inch #15-PH3 with isoweld° Fl-P-6.8-PVC 2 x 3-ft grid, staggered (min. 50 mil) induction welded to SFS isoweld° F3-P-6.8-PVC -37.5 Plates Plates with SFS isoweld® 3000 stand-up tool Min. psi One or more layers, any SFS Intec Dekfast DF-#14-PH3 or DF- z 4 ft per fastener Duro-Last (min. 40 mil), Duro-Last EV (min. 50 mil) or Duro-Tuff C-55. structural structural concrete u combination, min. 1.5-inch #15-PH3 with isoweld° F1-P-6.8-PVC 2 x 2-ft grid, staggered (min. 50 mil) induction welded to SFS isoweld° Fl-P-6.8-PVC -52.5 Plates Plates with SFS isoweld° 3000 stand-up tool Min. psi One or more layers, any SFS Intec Dekfast DF-#14-PH3 or DF- 3 per fastener Duro-Last (min. 40 mil), Duro-Last EV (min. 50 mil) or Duro-Tuff C-56. u structural concrete structural combination, min. 1.5-inch #15-PH3 with isoweld° Fl-P-6.8-PVC - 1.5 x 22-ft grid, staggered (min. 50 mil) induction welded to SFS isoweld° F1-P-6.8-PVC -82.5 Plates Plates with SFS isoweld° 3000 stand-up tool Min. 2,500 psi One or more layers, any SFS Intec Dekfast DF-#14-PH3 or DF 12-inch o.c. in rows spaced p Duro-Last (min. 40 mil), Duro-Last EV (min. 50 mil) or Duro-Tuff C-57. structural concrete combination, min. 1.5-inch, #15-PH3 with isoweld° Fl-P-6.8-PVC 60-inch o.c. (min. 50 mil) induction welded to SFS isoweld° F1-P-6.8-PVC -45.0 preliminarily attached (Note 5) Plates Plates with SFS isoweld® 3000 stand-up tool Min. 2,500 psi One or more layers, any SF5 Intec Dekfast DF-#14-PH3 or DF 6-inch o.c. in rows spaced Duro-Last (min. 40 mil) induction welded to SFS isoweld° F1-P- C-58. structural concrete combination, min. 1.5-inch, #15-PH3 with isoweld° F1-P-6.8-PVC 60-inch o.c. 6.8-PVC Plates with SFS isoweld° 3000 stand-up tool _g0.0 preliminarily attached (Note 5) Plates TRUFAST INDUCTION WELD:_ - Min. 2,500 psi One or more layers, any Trufast #14 HD or Trufast Fluted 1 per 5.33 ft' Duro-Last (min. 40 mil), Duro-Last EV (min. 50 mil) or Duro-Tuff C-59. structural concrete combination, min. 2-inch Concrete Nail with Trufast PVC IW (6 parts per 4x8 ft board on (min. 50 mil) induction welded to Trufast PVC IW Plates with -45.0* Plate a 2436-inch pattern) Trufast Induction Welding Tool and Magnets NEMO ETC, LLC Evaluation Report D9750.05.08-R10 for FL3559-Ri3 Certificate of Authorization #32455 6" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 25 of 44 NNEMO I etc. TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, .. .. RECOVER SYSTEM TYPE C-2: MECHANICALLY ATTACHED INSULATION, PLATE -BONDED ROOF COVER System Deck Insulation Layer Attach Roof Cover /Attach MDP No. (Note 1) (Note 14) Fasteners Density (psf) Trufast #14 HD or Trufast Fluted 1 per 4 ft' Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction C-60. Min. 2,500 psi One or more layers, any Concrete Nail with Trufast PVC IW (8 parts per 4x8 ft board on welded to Trufast PVC IW Plates with Trufast Induction Welding -52.5 structural concrete combination, min. 2-inch Plate a 24x24-inch pattern) Tool and Magnets Trufast #14 HD or Trufast Fluted 1 per 4 ftZ Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro-Tuff C-61. Min. 2,500 psi One or more layers, any Concrete Nail with Trufast PVC IW (8 parts per 4x8 ft board on (min. 60 mil) induction welded to Trufast PVC IW Plates with -60.0 structural concrete combination, min. 2-inch Plate a 24x24-inch pattern) Trufast Induction Welding Tool and Magnets Trufast #14 HD or Trufast Fluted 1 per 3.2 ft' Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction C-62. Min. 2,500 psi One or more layers, any Concrete Nail with Trufast PVC IW (10 parts per 48 ft board welded to Trufast PVC IW Plates with Trufast Induction Welding -60.0 structural concrete combination, min. 2-inch Plate on a 2420-inch pattern) Tool and Magnets Trufast #14 HD or Trufast Fluted 1 per 3.2 ft' Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro-Tuff C-63. Min. 2,500 psi One or more layers, any Concrete Nail with Trufast PVC IW (10 parts per 48 ft board (min. 60 mil) induction welded to Trufast PVC IW Plates with -67.5 structural concrete combination, min. 2-inch Plate on a 24x20-inch pattern) Trufast Induction Welding Tool and Magnets Trufast #14 HD or Trufast Fluted 1 per 2.7 ftZ Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction C-64. Min. 2,500 psi One or more layers, any Concrete Nail with Trufast PVC IW (12 parts per 4x8 ft board welded to Trufast PVC IW Plates with Trufast Induction Welding -67.5 structural concrete combination, min. 2-inch Plate per FM LPDS 1-29) Tool and Magnets Trufast #14 HD or Trufast Fluted 1 per 2.7 ftZ Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro-Tuff C-65. Min. 2,500 psi One or more layers, any Concrete Nail with Trufast PVC IW (12 parts per 4x8 ft board (min. 60 mil) induction welded to Trufast PVC IW Plates with -82.5 structural concrete combination, min. 2-inch Plate per FM LPDS 1-29) Trufast Induction Welding Tool and Magnets Trufast #14 HD or Trufast Fluted 1 per 2 ft' Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction C-66. Min. 2,500 psi One or more layers, any Concrete Nail with Trufast PVC IW (16 parts per 4x8 ft board welded to Trufast PVC IW Plates with Trufast Induction Welding -90.0 structural concrete combination, min. 2-inch Plate on a 12x24-inch pattern) Tool and Magnets Trufast #14 HD or Trufast Fluted 1 per 2 ftZ Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro-Tuff C-67. Min. 2,500 psi One or more layers, any Concrete Nail with Trufast PVC IW (16 parts per 48 ft board (min. 60 mil) induction welded to Trufast PVC IW Plates with -112.5 structural concrete combination, min. 2-inch Plate on a 12x24-inch pattern) Trufast Induction Welding Tool and Magnets Min. 2,500 psi One or more layers, any Trufast #14 HD or Trufast Fluted 1 per 1.8 ftZ Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction C-68. structural concrete combination, min. 2-inch Concrete Nail with Trufast PVC IW (18 parts per 48 ft board welded to Trufast PVC IW Plates with Trufast Induction Welding -105.0 Plate on an 18x16-inch pattern) Tool and Magnets Trufast #14 HD or Trufast Fluted 1 per 1.8 ft' Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro-Tuff C-69. Min. 2,500 psi One or more layers, any Concrete Nail with Trufast PVC IW (18 parts per 4x8 ft board (min. 60 mil) induction welded to Trufast PVC IW Plates with -120.0 structural concrete combination, min. 2-inch Plate on an 18x16-inch pattern) Trufast Induction Welding Tool and Magnets Min. 2,500 psi One or more layers, any Trufast #14 HD or Trufast Fluted 1 per 1.3 ftZ Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction C-70. structural concrete combination, min. 2-inch Concrete Nail with Trufast PVC IW (24 parts per 4x8 ft board welded to Trufast PVC IW Plates with Trufast Induction Welding -135.0 Plate on a 12x16-inch pattern) Tool and Magnets Min. 2,500 psi One or more layers, any Trufast #14 HD or Trufast Fluted 1 per 1.3 ftZ Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro-Tuff C-71. structural concrete combination, min. 2-inch Concrete Nail with Trufast PVC IW (24 parts per 48 ft board (min. 60 mil) induction welded to Trufast PVC IW Plates with -172.5 Plate on a 12x16-inch pattern) I Trufast Induction Welding Tool and Magnets NEMO ETC, LLC Evaluation Report D9750.05.08-R10 for FL3559-1113 _Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 26 of 44 ONEMOjetc. TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, • .. .. RECOVER PLATE-BONDEDSYSTEM TYPE C-2: MECHANICALLY ATTACHED INSULATION, ROOF COVER System Deck Insulation Layer Attach Roof Cover /Attach MDP Fasteners Density No. (Note 1) (Note 14) (Psf) Trufast #14 HD or Trufast Fluted 1 per 1 ft2 Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction C 72. Min. 2,500 psi One or more layers, any Concrete Nail with Trufast PVC IW (32 parts per 4x8 ft board welded to Trufast PVC IW Plates with Trufast Induction Welding -142.5 structural concrete combination, min. 2-inch Plate per FM LPDS 1-29) Tool and Magnets Trufast #14 HD or Trufast Fluted 1 per 1 ft' Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro-Tuff C-73. Min. psi One or more layers, any Concrete Nail with Trufast PVC IW (32 parts per 4x8 ft board (min. 60 mil) induction welded to Trufast PVC IW Plates with -217.5 u structural ral concrete combination, min. 2-inch Plate per FM LPDS 1-29) Trufast Induction Welding Tool and Magnets Min. 2,500 psi One or more layers, any Trufast #14 HD or Trufast Fluted 12-inch o.c. in rows spaced Duro-Last (min. 40 mil), Duro-Last EV (min. 50 mil) or Duro-Tuff C-74. structural concrete combination, min. 2-inch, Concrete Nail with Trufast PVC IW 60-inch o.c. (min. 50 mil) induction welded to Trufast PVC IW Plates with -45.0 preliminarily attached Plate Trufast Induction Welding Tool and Magnets Min. 2,500 psi One or more layers, any Trufast #14 HD or Trufast Fluted 12-inch o.c. in rows spaced Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction C-75. structural concrete combination, min. 2-inch, Concrete Nail with Trufast PVC IW 48-inch o.c. welded to Trufast PVC IW Plates with Trufast Induction Welding -52.5 preliminarily attached Plate Tool and Magnets Min. , 500 psi 2 One or more layers, any Trufast #14 HD or Trufast Fluted 12-inch o.. in rows spaced c Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro-Tuff C-76. structural concrete combination, min. 2-inch, Concrete Nail with Trufast PVC IW 48-inch o.c. (min. 60 mil) induction welded to Trufast PVC IW Plates with -60.0 preliminarily attached Plate Trufast Induction Welding Tool and Magnets Min. 2,500 psi One or more layers, any Trufast #14 HD or Trufast Fluted 12-inch o.c. in rows spaced Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction C 77 structural concrete combination, min. 2-inch Concrete Nail with Trufast PVC IW 36-inch o.c. welded to Trufast PVC IW Plates with Trufast Induction Welding 60.0 Plate Tool and Magnets Min. 2,500 psi One or more layers, any Trufast #14 HD or Trufast Fluted 12-inch o.c. in rows spaced Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro-Tuff C 78. structural concrete combination, min. 2-inch Concrete Nail with Trufast PVC IW 36-inch o.c. (min. 60 mil) induction welded to Trufast PVC IW Plates with -82.5 Plate Trufast Induction Welding Tool and Magnets Min. 2,500 psi One or more layers, any Trufast #14 HD or Trufast Fluted 6-inch o.c. in rows spaced Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction C-79. structural concrete combination, min. 2-inch, Concrete Nail with Trufast PVC IW 72-inch o.c. welded to Trufast PVC IW Plates with Trufast Induction Welding -67.5 preliminarily attached Plate Tool and Magnets Min. 2,500 psi One or more layers, any Trufast #14 HD or Trufast Fluted 6-inch o.. in rows spaced c Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro-Tuff C-80. structural concrete combination, min. 2-inch, Concrete Nail with Trufast PVC IW 72-inch o.c. (min. 60 mil) induction welded to Trufast PVC IW Plates with -75.0 preliminarily attached Plate Trufast Induction Welding Tool and Magnets Min. 2,500 psi One or more layers, any Trufast #14 HD or Trufast Fluted 6-inch o.. in rows spaced c Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction C-81. structural concrete combination, min. 2-inch, Concrete Nail with Trufast PVC IW 60-inch o.c. welded to Trufast PVC IW Plates with Trufast Induction Welding -75.0 preliminarily attached Plate Tool and Magnets One or more layers, any Trufast #14 HD or Trufast Fluted Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro-Tuff C-82. Min. 2,500 psi combination, min. 2-inch, Concrete Nail with Trufast PVC IW 6-inch o.. in rows spaced c (min. 60 mil) induction welded to Trufast PVC IW Plates with -90.0 structural concrete preliminarily attached Plate 60-inch o.c. Trufast Induction Welding Tool and Magnets Min. 2,500 psi One or more layers, any Trufast #14 HD or Trufast Fluted 6-inch o.c. in rows spaced Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction C-83. structural concrete combination, min. 2-inch, Concrete Nail with Trufast PVC IW 48-inch o.c. welded to Trufast PVC IW Plates with Trufast Induction Welding -90.0 preliminarily attached Plate Tool and Magnets NEMO ETC, LLC Evaluation Report D9750.05.08-1310 for FL1559-R13 Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 27 of 44 NNEMOjetc. TABLE 313: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, .. OR • PLATE-BONDEDSYSTEM TYPE C-2: MECHANICALLY ATTACHED INSULATION, ROOF COVER System Deck Insulation Layer Attach Roof Cover /Attach MDP No. (Note 1) (Note 14) Fasteners Density (psf) Min. 2,500 psi One or more layers, any Trufast #14 HD or Trufast Fluted 6-inch o.c. in rows spaced Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro-Tuff C-84. structural concrete combination, min. 2-inch, Concrete Nail with Trufast PVC IW 48-inch o.c. (min. 60 mil) induction welded to Trufast PVC IW Plates with -112.5 preliminarily attached Plate Trufast Induction Welding Tool and Magnets Min. 2,500 psi One or more layers, any Trufast #14 HD or Trufast Fluted 6-inch o.c. in rows spaced Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction C-85. structural concrete combination, min. 2-inch Concrete Nail with Trufast PVC IW 36-inch o.c. welded to Trufast PVC IW Plates with Trufast Induction Welding -112.5 Plate Tool and Magnets Min. 2,500 psi One or more layers, any Trufast #14 HD or Trufast Fluted 6-inch o.c. in rows spaced Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro-Tuff C 86. structural concrete combination, min. 2-inch Concrete Nail with Trufast PVC IW 36-inch o.c. (min. 60 mil) induction welded to Trufast PVC IW Plates with -150.0 Plate Trufast Induction Welding Tool and Magnets TABLE 3C: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEM TYPE • • INSULATION,i ROOF COVER Insulation (Note 14) Roof Cover System Deck Membrane Fasteners MDP Attach (psf) Attach No. (Note 1) Type (Note 5) STANDARD LAP SYSTEMS: Min. 2,500 psi (Optional) One or more Prelim. Duro-Last, min. 40 Duro-Last #14 HD Fasteners with Standard Lap System fastened 9-inch o.c. within 3-inch wide C 87. structural concrete layers, any combination attached mil Duro-Last Cleat Plates tabs spaced 60-inch o.c. -37.5 Min. 2,500 psi (Optional) One or more Prelim. Duro-Last, min. 40 Duro-Last Concrete Screws #14 or Standard Lap System fastened 6-inch o.c. within 3-inch wide C 88 Duro-Last Concrete Nails with Duro- -60.0 structural concrete layers, any combination attached mil tabs spaced 84-inch o.c. Last 2.4-inch Barbed Metal Plates DURO-ROOF LAP SYSTEMS: Min. 2,500 psi (Optional) One or more Prelim. Duro-Last, min. 60 Duro-Last #14 HD Fasteners with Duro-Roof Lap System fastened 6-inch o.c. within 6-inch wide C 89. structural concrete layers, any combination attached mil Duro-Last Cleat Plates tabs spaced 120-inch o.c. Tab Sealer 4725 at max. 60 ft2/gal. 37.5 Min. 2,500 psi (Optional) One or more Prelim. Duro-Last, min. 40 Duro-Last Concrete Screws #14 or Duro-Roof Lap System fastened 12-inch o.c. within 6-inch wide C-90. Duro-Last Concrete Nails with Duro- -52.5 structural concrete layers, any combination attached mil tabs spaced 57-inch o.c. Tab Sealer 4725 at max. 60 ft2/gal. Last --inch Metal Plates Min. 2,500 psi (Optional) One or more Prelim. Duro-Last, min. 40 Duro-Last Concrete Screws #14 or Duro-Roof Lap System fastened 6-inch o.c. within 3-inch wide C-91. Duro-Last Concrete Nails with Duro- -67.5 structural concrete layers, any combination attached mil tabs spaced 60-inch o.c. Tab Sealer 4725 at max. 60 ft2/gal. Last Batten Bar Min. 2,500 psi (Optional) One or more Prelim. Duro-Last, min. 40 Duro-Last Concrete Screws #14 or Duro-Roof Lap System fastened 6-inch o.c. within 6-inch wide C 92 Duro-Last Concrete Nails with Duro- 82 5 structural concrete layers, any combination attached mil, tabs spaced 120-inch o.c. Tab Sealer 4725 at max. 60 ft2/gal. Last --inch Metal Plates Min. 2,500 psi (Optional) One or more Prelim. Duro-Last, min. 40 Duro-Last Concrete Screws #14 or Duro-Roof Lap System fastened 6-inch o.c. within 6-inch-wide C 93 structural concrete layers, any combination attached mil Duro-Last Concrete Nails with OMG 2- tabs spaced 25-inch o.c. Tab Sealer 4725 at max. 60 ft2/gal. -142.5 3/8" Eyehook Plates NEMO ETC, LLC Certificate of Authorization #32455 ©2019 NEMO ETC, LLC 6TM EDITION (2017) FBC NON-HVHZ EVALUATION Duro-Last Single Ply Roof Systems; (800) 248-0280 Evaluation Report D9750.05.08-1110 for FL1559-1113 Revision 10: 10/17/2019 Appendix 1, Page 28 of 44 ONEMOjetc. System No. Deck (Note 1) Primer TABLE 3D: STRUCTURAL CONCRETE DECKS - SYSTEM TYPE F: Vapor Barrier NEW CONSTRUCTION .. REROOF .:... ROOF COVER Roof Cover (Note 16) MDP (psf) C-94. Structural concrete None Duro-Last Vapor Barrier, self -adhering Duro-Fleece or Duro-Fleece Plus / Duro-Fleece CR-20 (splatter applied) -502.5 C-95. Structural concrete ASTM D41 Duro-Last Torch Down Vapor Barrier, torch -applied Duro-Fleece or Duro-Fleece Plus / Duro-Fleece CR-20 (splatter applied) -502.5 C-96. Structural concrete None None Duro-Fleece or Duro-Fleece Plus / Duro-Fleece WB II Adhesive -673.0 C-97. Structural concrete None None Duro-Fleece or Duro-Fleece Plus / Duro-Fleece CR-20 (splatter applied) -1,025.0 NEMO ETC, LLC Evaluation Report D9750.05.08-R10 for FL3559-1113 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 29 of 44 OMEMO I etc. TABLE 4A: LIGHTWEIGHT CONCRETE OVER STEEL DECKS - NEW CONSTRUCTION OR REROOF SYSTEM TYPE A- BONDED INSULATION, BONDED ROOF COVER Base Insulation Layer Coverboard System Deck (Note 1) LWC (Note 15) Attach Attach Roof Cover �PD Type Type (Notes 6 & 7) (Notes 6 & 7) PRE-EXISTENT CELLULAR LWC: BAREBACK MEMBRANE APPLICATIONS: Min. 22 ga., type Min. 200 psi, min. 2-inch thick cellular (Optional) Min. 1.5-inch ACFoam Ashland Min. 0.25-inch Dens Ashland LWC-1. BV steel lightweight insulating concrete 11, Duro-Guard ISO 11-A Pliodeck Deck Pliodeck Duro-Last / WB 1 -37.5 Min. 22 ga., type Min. 200 psi, min. 2-inch thick cellular Min. 1.5-inch ACFoam 11, Duro- Ashland (Optional) Additional Ashland LWC-2. BV steel lightweight insulating concrete Guard ISO II -A Pliodeck layers of base insulation Pliodeck Duro-Last / SB I or WB II -45.0 LWC-3. Min. 22 ga., type Min. 200 psi, min. 2-inch thick cellular Min. 1.5-inch ACFoam 11, Duro- Ashland (Optional) Additional Ashland Duro-Last, Duro-Last EV or BV steel lightweight insulating concrete Guard ISO 11-A Pliodeck layers of base insulation Pliodeck Duro-Tuff/ 5B IV or WB II 45.0 Min. 22 ga., type Min. 200 psi, min. 2-inch thick cellular (Optional) Min. 1.5-inch ACFoam Min. 0.25-inch Dens LWC-4. BV steel lightweight insulating concrete 11, Duro-Guard ISO II -A CR-20 Deck CR-20 Duro-Last / WB 1 -37.5 Min. 22 ga., type Min. 200 psi, min. 2-inch thick cellular Min. 1.5-inch ACFoam 11, Duro- (Optional) Additional LWC-5. BV steel lightweight insulating concrete Guard ISO II -A CR-20 layers of base insulation CR-20 Duro-Last / SB I or WB 11 -45.0 LWC-6. Min. 22 ga., type Min. 200 psi, min. 2-inch thick cellular Min. 1.5-inch ACFoam II, Duro- (Optional) Additional Duro-Last, Duro-Last EV or BV steel lightweight insulating concrete Guard 150 II -A CR-20 layers of base insulation CR-20 Duro-Tuff/ SB IV or WB II 45.0 DURo-FLEECE AND DURO-FLEECE PLUS MEMBRANE APPLICATIONS: LWC-7. Min. 22 ga., type Min. 200 psi, min. 2-inch thick cellular Min. 1.5-inch ACFoam 11, Duro- Ashland (Optional) Additional Ashland Duro-Fleece or Duro- BV steel lightweight insulating concrete Guard ISO II -A Pliodeck layers of base insulation Pliodeck Fleece Plus / WB II 45.0 Min. 22 ga., type Min. 200 psi, min. 2-inch thick cellular Min. 1.5-inch ACFoam 11, Duro- (Optional) Additional Duro-Fleece or Duro- LWC-8. BV steel lightweight insulating concrete Guard ISO II -A CR-20 layers of base insulation CR-20 Fleece Plus / WB II -45.0 TABLE 4B: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE A: BONDED INSULATION, BONDED ROOF COVER Base Insulation layer Coverboard System Deck LWC (Note 15) Attach Attach Roof Cover MDP No. (Note 1) Type Type (psf) (Notes 6 & 7) (Notes 6 & 7) PRE-EXISTENT CELLULAR LWC: BAREBACK MEMBRANE APPLICATIONS: Min. 200 psi, min. 2-inch thick Structural (Optional) Min. 1.5-inch ACFoam 11, Duro- Ashland Ashland LWC-9. concrete cellular lightweight insulating Guard ISO II -A Pliodeck Min. 0.25-inch Dens Deck Pliodeck Duro-Last / WB 1 -37.5 concrete Min. 200 psi, min. 2-inch thick Structural Ashland (Optional) Additional Ashland LWC-10. cellular lightweight insulating Min. 1.5-inch ACFoam 11, Duro-Guard ISO II -A Duro-Last / SB I or WB-11 -45.0 concrete Pliodeck layers of base insulation Pliodeck concrete NEMO ETC, LLC Certificate of Authorization #32455 ©2019 NEMO ETC, LLC 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Duro-Last Single Ply Roof Systems; (800) I48-0280 Evaluation Report D9750.05.08-1110 for FL3559-R13 Revision 10: 10/17/2019 Appendix 1, Page 30 of 44 System Deck LWC (Note 15) No. (Note 1) Min. 200 psi, min. 2-inch thick Structural LWC-11. cellular lightweight insulating concrete concrete Min. 200 psi, min. 2-inch thick Structural LWC-12. cellular lightweight insulating concrete concrete Structural Min. 200 psi, min. 2-inch thick LWC-13. cellular lightweight insulating concrete concrete Min. 200 psi, min. 2-inch thick Structural LWC-14. cellular lightweight insulating concrete concrete DURO-FLEECE AND DURO-FLEECE PLUS MEMBRANE APPLICATIONS: Min. 200 psi, min. 2-inch thick Structural LWC-15. cellular lightweight insulating concrete concrete Structural Min. 200 psi, min. 2-inch thick LWC-16. cellular lightweight insulating concrete concrete CELCORE(FL2D37): BAREBACK MEMBRANE APPLICATIONS: Structural Min. 200 psi, min. 2-inch thick LWC-17. concrete Celcore Cellular Concrete Structural Min. 200 psi, min. 2-inch thick LWC-18. concrete Celcore Cellular Concrete DURO-FLEECE AND DURO-FLEECE PLUS MEMBRANE APPLICATIONS: Structural Min. 200 psi, min. 2-inch thick LWC-19. concrete Celcore Cellular Concrete ELASTIZELL (FL4994): BAREBACK MEMBRANE APPLICATIONS: Structural Min. 200 psi, min. 2-inch thick LWC-20. I concrete Elastizell. Base Insulation Layer Coverboard Attach Attach Type (Notes 6 & 7) Type (Notes 6 & Min. 1.5-inch ACFoam II, Duro-Guard 150 II -A Ashland (Optional) Additional Ashland Pliodeck layers of base insulation Pliodeck (Optional) Min. 1.5-inch ACFoam II, Duro- Guard ISO II -A CR-20 Min. 0.25-inch Dens Deck CR-20 (Optional) Additional Min. 1.5-inch ACFoam II, Duro-Guard 150 II -A CR-20 CR-20 layers of base insulation (Optional) Additional Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A CR-20 CR-20 layers of base insulation Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A Ashland Pliodeck Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A I CR-20 Min. 1.5-inch ACFoam II, Duro-Guard 150 II -A I CR-20 Min. 1.5-inch ACFoam II, Duro-Guard 150 II -A, H-Shield, Duro-Guard ISO II-H, ENRGY 3 or CR-20 Duro-Guard ISO II-G Min. 1.5-inch ACFoam 11, Duro-Guard 150 II -A, H-Shield, Duro-Guard ISO 11-H, ENRGY 3 or CR-20 Duro-Guard ISO II-G (Optional) Additional Ashland layers of base insulation I Pliodeck (Optional) Additional layers of base insulation CR-20 (Optional) Additional CR-20 layers of base insulation Min. 0.25-inch SECUROCK Gypsum -Fiber CR-20 Roof Board Min. 0.25-inch SECUROCK Gypsum -Fiber CR-20 Roof Board Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A I Ashland I (Optional) Additional Ashland Pliodeck layers of base insulation I Pliodeck ONEMOletc, Roof Cover I MDP (psf) Duro-Last, Duro-Last EV or Duro-Tuff / 5B IV or WB II 45.0 Duro-Last / WB 1 1 -37.5 Duro-Last / SB I or WB II 1 -45.0 Duro-Last, Duro-Last EV or 45.0 Duro-Tuff / SB IV or WB II Duro-Fleece or Duro- Fleece Plus / WB II 45.0 Duro-Fleece or Duro- Fleece Plus / Duro-Fleece -45.0 CR-20 (splatter) or WB II Duro-Last / WB 1 -82.5 Duro-Last, Duro-Last EV or -222 5 Duro-Tuff / SB IV or WB II Duro-Fleece or Duro- Fleece Plus / Duro-Fleece 222.5 CR-20 (splatter) or WB II Duro-Last / WB 1 I -82.5 NEMO ETC, LLC Evaluation Report D9750.05.08-R10 for FL3559-1113 Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 31 of 44 NNEMOjetc. 4B: LIGHTWEIGHT CONCRETETABLE OVER • rECKS - NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE A: BONDED INSULATION,BONDED ROOF COVER Base Insulation layer Coverboard System Deck LWC (Note 15) Roof Cover MDP Attach Attach No. (Note 1) Type Type (psf) (Notes 6 & 7) (Notes 6 & 7) Structural Min. 200 psi, min. 2-inch thick Ashland Min. 0.25-inch Ashland Duro-Last, Duro-Last EV or LWC-21. Min. 2-inch ISO 95+ GL SECUROCK Gypsum -Fiber -105.0 concrete Elastizell. Pliodeck Pliodeck Duro-Tuff / SB IV or WB II Roof Board Ashland Min. 0.25-inch Ashland Structural Min. 200 psi, min. 2-inch thick Duro-Last, Duro-Last EV or LWC-22. Min. 2-inch ISO 95+ GL Pliodeck, 6- SECUROCK Gypsum -Fiber Pliodeck, 6-inch -187.5 concrete Elastizell. Duro-Tuff / SB IV or WB II inch o.c. Roof Board O.C. Structural Min. 200 psi, min. 2-inch thick (Optional) Additional LWC-23. Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A CR-20 CR-20 Duro-Last / WB 1 -82.5 concrete Elastizell layers of base insulation Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A, Min. 0.25-inch LWC-24. Structural Min. 200 psi, min. 2-inch thick H-Shield, Duro-Guard ISO II-H, ENRGY 3 or CR-20 SECUROCK Gypsum -Fiber CR-20 Duro-Last, Duro-Last EV or -180.0 concrete Elastizell Duro-Tuff/ SB IV or WB II Duro-Guard ISO II-G Roof Board DURO-FLEECE AND DURo-FLEECE PLUS MEMBRANE APPLICATIONS: Structural Min. 200 psi, min. 2-inch thick Ashland Min. 0.25-inch Ashland Duro-Fleece or Duro- LWC-25. Min. 2-inch ISO 95+ GL SECUROCK Gypsum -Fiber Fleece Plus / Duro-Fleece -105.0 concrete Elastizell. Pliodeck Roof Board Pliodeck CR-20 (splatter) or WB II Structural Min. 200 psi, min. 2-inch thick Ashland Min. 0.25-inch Ashland Duro-Fleece or Duro- LWC-26. Min. 2-inch ISO 95+ GL Pliodeck, 6- SECUROCK Gypsum -Fiber Pliodeck, 6-inch Fleece Plus / Duro-Fleece -187.5 concrete Elastizell. inch o.c. Roof Board O.C. CR-20 (splatter) or WB II Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A, Min. 0.25-inch Duro-Fleece or Duro- Structural Min. 200 psi, min. 2-inch thick LWC-27. H-Shield, Duro-Guard ISO II-H, ENRGY 3 or CR-20 SECUROCK Gypsum -Fiber CR-20 Fleece Plus / Duro-Fleece 180.0 concrete Elastizell Duro-Guard ISO 11-G Roof Board CR-20 (splatter) or WB II MEARLCRETE(FL13492): BAREBACK MEMBRANE APPLICATIONS: Structural Min. 200 psi, min. 2-inch thick (Optional) Additional LWC-28. concrete Mearlcrete Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A CR-20 layers of base insulation CR-20 Duro-Last / WB 1 -82.5 Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A, Min. 0.25-inch LWC-29. Structural Min. 200 psi, min. 2-inch thick H-Shield, Duro-Guard ISO II-H, ENRGY 3 or CR-20 SECUROCK Gypsum -Fiber CR-20 Duro-Last, Duro-Last EV or -240.0 concrete Mearlcrete Duro-Guard ISO II-G Roof Board Duro-Tuff / SB IV or WB II DURo-FLEECE AND DURO-FLEECE PLUS MEMBRANE APPLICATIONS: StructuralEMea psi, min. 2-inch thick Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A, Min. 0.25-inch Duro-Fleece or Duro- LWC-30. H-Shield, Duro-Guard ISO II-H, ENRGY 3 or CR-20 SECUROCK Gypsum -Fiber CR-20 Fleece Plus / Duro-Fleece -240.0 concretete Duro-Guard ISO II-G Roof Board CR-20 (splatter) or WB II NEMO ETC, LLC Evaluation Report D9750.05.08-1110 for FL1559-R13 Certificate of Authorization #32455 CH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 32 of 44 OMEMO I etc. TABLE 4C: LIGHTWEIGHT CONCRETE OVER STEEL DECKS - NEW CONSTRUCTION ...... SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE BONDEDROOF COVER System1 7- L_ Deck (Note 1) LWC (Note 15) Base Sheet Roof Cover (Note 16) MDP (psf) No. Type Fasteners Attach ELASTIZELL (FL4994): Min. 22 ga., type BV, Grade Min. 320 psi, min. 2-inch thick CertainTeed Flexiglas 7.5-inch o.c. at the 3-inch laps and 7.5- Duro-Fleece or Duro- Fleece Plus / Duro- LWC-31. 33 steel at max. 7 ft spans Elastizell cellular lightweight concrete Base Sheet, GAFGLAS Trufast FM-90 inch o.c. in one staggered row in the Fleece CR-20 (splatter 22.5 cast with Zell Fibers in the mix. #75 center of the sheet applied) Min. 22 ga., type BV, Grade Min. 380 psi, min. 2-inch thick CertainTeed Flexiglas Trufast Twin- 7.5-inch o.c. at the 3-inch laps and 7.5- Duro-Fleece or Duro- Fleece Plus / Duro- LWC-32. 33 steel at max. 7 ft spans Elastizell cellular lightweight concrete Base Sheet, GAFGLAS Loc Nails (min. inch o.c. in one staggered row in the Fleece CR-20 (splatter -37.5 cast with Zell Fibers in the mix. #75, JM PermaPly 28 1.8-in) center of the sheet applied) Min. 350 psi, min. 2-inch thick CertainTeed Plexiglas Trufast Twin- 7.5-inch o.c. at the 3-inch laps and 7.5- Duro-Fleece or Duro- LWC-33. Min. ga., type BV, Grade Elastizell cellular lightweight concrete Base SheetGAFGLAS Loc Nails (min, inch o.c. in two, equally spaced, Fleece Plus /Duro -67.5 33 steelel at max. 7 ftt spans cast with Zell Fibers in the mix. , #75, JM PermaPly 28 1.8-in) staggered row in the center of the Fleece CR-20 (splatter sheet applied) TABLE 41): LIGHTWEIGHT CONCRETE OVER STEEL DECKS - NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEMTYPEF: NON -INSULATED, BONDED ROOF COVER System Deck (Note 1) No. LWC (Note 15) Roof Cover (Note 16) _FM DP (psf) CELCORE(FL2037): LWC-34. Min. 22 ga., type BV, Grade 33 Min. 350 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture, Duro-Fleece or Duro-Fleece Plus / steel deck at max. 4 ft spans with optional 1-inch thick, 1.0 pcf EPS holey board and surfacing of Celcore PVA Curing Compound. Duro-Fleece Adhesive 37.5 LWC-35. Min. 22 ga., type BV, Grade 33 Min. 350 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture, Duro-Fleece or Duro-Fleece Plus / WB II -60.0 steel deck at max. 6 ft spans with optional 1-inch thick, 1.0 pcf EPS holey board and surfacing of Celcore PVA Curing Compound. ELASTIZELL (FL4994): LWC-36. Min. 22 ga., type BV, Grade 33 Min. 350 psi, min. 2-inch thick Elastizell cellular lightweight concrete cast with Zell Fibers in the mix. Duro-Fleece or Duro-Fleece Plus / -52.5 steel at max. 7 ft spans Duro-Fleece CR-20 (splatter applied) TABLE 4E: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE F: NON -INSULATED, BONDED ROOF COVER System Deck (Note 1) No. LWC (Note 15) Roof Cover (Note i6) TMDP (psf) CELCORE (FL2037): LWC-37. Min. 2,500 psi structural concrete Min. 350 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture, Duro-Fleece or Duro-Fleece Plus / 82.5 with optional 1-inch thick, 1.0 pcf EPS holey board and surfacing of Celcore PVA Curing Compound. WB II LWC-38. Min. 2,500 psi structural concrete Min. 350 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture, Duro-Fleece or Duro-Fleece Plus / -232.5 with optional 1-inch thick, 1.0 pcf EPS holey board and surfacing of Celcore PVA Curing Compound. Duro-Fleece Adhesive at 4-inch o.c. NEMO ETC, LLC Evaluation Report D9750.05.08-R10 for FL1559-1113 Certificate of Authorization #32455 6-EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEW ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 33 of 44 OMEMO I etc, System Deck Base Insulation Layer Top Insulation Layer No. ) (Notes 1 & 12) Type Attach Type Attach (Notes 6 & 7) Roof Cover (Note 16) MDP (psf) CWF-1. Existing min. 2.5-inch Tectum Min. 0.25-inch SECUROCK Insta-Stik, 6- None N/A Duro-Last, Duro-Last EV or Duro-Tuff / SB Plank or Tectum LS Plank Gypsum -Fiber Roof Board inch o.c. -150.0 IV or WB II CWF-2. Existing min. 2.5-inch Tectum Min. 0.25-inch SECUROCK Insta-Stik, 6- None N/A Duro-Fleece or Duro-Fleece Plus / Duro- Plank or Tectum LS Plank Gypsum -Fiber Roof Board inch o.c. I I -150.0 I Fleece CR-20 (splatter) or WB II TABLE 5B: CEMENTITIOUS WOOD FIBER rCONSTRUCTION,••• • OR RECOVER SYSTEM TYPE r r INSULATION,r ROOF COVER Insulation (Note 14) Roof Cover System Deck (Note 1) Attach M DP No. Type Membrane Fasteners Attach (psf) (Note 5) Min. 3-inch One or more layers, any Prelim. Duro-Last, min. Duro-Last Auger Fastener (min. 2-inch Standard Lao System fastened 6-inch o.c. within 6-inch wide CWF-3. Tectum I combination, min. 1.5-inch attach 40-mil embedment) with 2" Auger Plate tabs spaced 57-inch o.c. 45.0 Min. 3-inch One or more layers, any Prelim. Duro-Last, min. Duro-Last Auger Fastener (min. 2-inch Duro-Roof Lao System fastened 6-inch o.c. within 6-inch wide CWF-4. Tectum I combination, min. 1.5-inch attach 40-mil embedment) with 2" Auger Plate tabs spaced 57-inch o.c. Tab Sealer 4725 at max. 60 ft2/gal 52.5 TABLE 5C: CEMENTITIOUS WOOD FIBER rCONSTRUCTION,••• • OR RECOVER SYSTEM TYPE E-1: • r MECHANICALLY ATTACHED ROOF COVER Roof Cover System Deck (Note 1) MDP Fasteners No. Membrane Attach (psf) Type ENERFOAM Installation CWF-5. Min. 2-inch Duro-Last, Duro-Last Auger Fastener (min. 2- N/ A Standard Lao System fastened 6-inch o.c. at 3-inch wide Tectum I min. 40-mil inch embedment) tabs spaced 60-inch o.c. 30.0 Duro-Last Auger Fastener (min. 2- 7/16-inch diameter x 2.5-inch deep pilot holt filled with CWF-6. Min. 3-inch Duro-Last, inch embedment) with 2" Auger Dupont ENERFOAM followed by fastener installation within Standard Lao System fastened 6-inch o.c. at 3-inch wide -37.5 Tectum I min. 40-mil Plate and Dupont ENERFOAMT1 20-40 seconds after dispensing the foam tabs spaced 60-inch o.c. NEMO ETC, LLC Evaluation Report D9750.05.08-R10 for FL3559-Ri3 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 34 of 44 NNEMOjetc. TABLE 6A: GYPSUM DECKS - REROOF (TEAR -OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF Base Insulation Layer Top Insulation Layer System Deck (Notes 1 & 12) Attach Attach Roof Cover (Note 16) � PD Type Type (Notes 6 & 7) (Notes 6 & 7) BAREBACK MEMBRANE APPLICATIONS: - G-1. Existing poured gypsum (Optional) Min. 1.5-inch ACFoam II, CR-20 Min. 0.25-inch Dens Deck CR-20 Duro-Last / WB 1 -37.5 or gypsum plank Duro-Guard ISO II -A G 2 Existing poured gypsum Min. 1.5-inch ACFoam 11, Duro-Guard CR-20 (Optional) Additional layers of base insulation CR-20 Duro-Last / SB I or WB II -45.0 or gypsum plank 15011-A G-3. Existing poured gypsum Min. 1.5-inch ACFoam 11, Duro-Guard CR-20 (Optional) Additional layers of base insulation CR-20 Duro-Last, Duro-Last EV or -45.0 or gypsum plank ISO II -A Duro-Tuff / SB IV or WB II G-4. Existing poured gypsum Min. 1.5-inch ACFoam 11, Duro-Guard CR-20 (Optional) Additional layers of base insulation CR-20 Duro-Last / WB 1 -82.5 or gypsum plank 150 II -A Existing poured gypsum Min. 1.5-inch ACFoam 11, Duro-Guard Duro-Last, Duro-Last EV or G-5. or gypsum plank ISO II -A, H-Shield, Duro-Guard ISO 11-H, CR-20 Min. 0.25-inch SECUROCK Gypsum -Fiber Roof Board CR-20 Duro-Tuff / SB IV or WB II -247.5 ENRGY 3 or Duro-Guard ISO II-G DURO-FLEECE OR DURO-FLEECE PLUS MEMBRANE APPLICATIONS: G-6. Existing poured gypsum Min. 1.5-inch ACFoam II, Duro-Guard CR-20 (Optional) Additional layers of base insulation CR-20 Duro-Fleece or Duro-Fleece -45.0 or gypsum plank ISO II -A Plus / WB II Existing poured gypsum Min. 1.5-inch ACFoam 11, Duro-Guard Duro-Fleece or Duro-Fleece G 7. or gypsum plank 150 II -A, H-Shield, Duro-Guard ISO II-H, CR-20 Min. 0.25-inch SECUROCK Gypsum -Fiber Roof Board CR-20 Plus / Duro-Fleece CR-20 -247.5 ENRGY 3 or Duro-Guard ISO II-G (splatter) or WB 11 Existing poured gypsum Min. 1.5-inch ACFoam II, Duro-Guard Trufast Min. 0.5-inch Duro-Guard ISO HD -A or Duro-Guard ISO Trufast Duro-Fleece or Duro-Fleece G-8. or gypsum plank ISO II -A, ENRGY 3 CGF, Duro-Guard ISO Roofing HD-H Roofing Plus / Trufast Roofing -165.0 III-G, H-Shield CG, Duro-Guard ISO III-H Adhesive Adhesive Adhesive, ribbons 4" o.c. Min. 1.5-inch ACFoam II, Duro-Guard Trufast Min. 0.25-inch Dens Deck, Dens Deck Prime, DEXcell FA Trufast Duro-Fleece or Duro-Fleece G 9 Existing g poured gypsum ISO II -A, ENRGY 3 CGF, Duro-Guard ISO Roofing Glass Mat Roof Board, SECUROCK Gypsum -Fiber Roof Roofing Plus /Trufast Roofing -195.0 or gypsum plank III-G, H-Shield CIS, Duro-Guard ISO III-H Adhesive Board or SECUROCK Glass -Mat Roof Board or min. Adhesive Adhesive, ribbons 4" o.c. 7/16" DEXcell Cement Roof Board Existing poured gypsum Min. 1.5-inch ACFoam II, Duro-Guard Trufast Trufast Duro-Fleece or Duro-Fleece G-10. or gypsum plank ISO II -A, ENRGY 3 CGF, Duro-Guard ISO Roofing (Optional) Additional layers of base insulation Roofing Plus / Trufast Roofing -217.5 III-G, H-Shield CIS, Duro-Guard ISO III-H Adhesive Adhesive Adhesive, ribbons 4" o.c. TABLE 6B: GYPSUM DECKS - •• • OR RECOVER SYSTEM TYPE • • INSULATION,• ROOF COVER System Deck Insulation Roof Cover No. (Note 1) Type Attach Membrane Fasteners (Note 11) MDP (psf) Attach G-11. Existing poured gypsum One or more layers, Prelim. Duro-Last, min. 40 mil, Duro-Last Auger Fastener Standard Lao System fastened 6-inch o.c. within 6-inch wide -45.0 or gypsum plank any combination Attached with 2" Auger Plate tabs spaced 57-inch o.c. G-12. Existing poured gypsum One or more layers, Prelim. Duro-Last, min. 40 mil, Duro-Last Auger Fastener Duro-Roof Lao System fastened 6-inch o.c. within 6-inch wide -60.0 or gypsum plank any combination attached with 2" Auger Plate tabs spaced 57-inch o.c. Tab Sealer 4725 at max. 60 ft2/gal NEMO ETC, LLC Evaluation Report D9750.05.08-R10 for FL1559-R33 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 35 of 44 ONEMOjetc. TABLEM RECOVER APPLICATIONS SYSTEM TYPE A: BONDED INSULATION, BONDED ROOF Base Insulation Layer Top Insulation Layer System Substrate MDP Type Attach No. (Notes 1 & 12) Attach Roof Cover (Note 16) Type (psf) (Notes 6 & 7) (Notes 6 & 7) BAREBACK MEMBRANE APPLICATIONS: R-1. Existing asphaltic BUR or mineral (Optional) Min. 1.5-inch ACFoam II, Duro- Ashland Pliodeck, Ashland Pliodeck, surface cap sheet Guard ISO II -A 6-inch o.c Min. 0.25-inch Dens Deck 6-inch o.c Duro-Last / WB I 37.5 R 2 Existing asphaltic BUR or mineral Min. 1.5-inch ACFoam 11, Duro-Guard 150 II -A Ashland Pliodeck, (Optional) Additional layers Ashland Pliodeck, Duro-Last / SB I or WB II -45.0 surface cap sheet 6-inch o.c of base insulation 6-inch o.c R-3. Existing asphaltic BUR or mineral Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A Ashland Pliodeck, (Optional) Additional layers Ashland Pliodeck, Duro-Last, Duro-Last EV or 45.0 surface cap sheet 6-inch o.c of base insulation 6-inch o.c Duro-Tuff / 5B IV or WB II R 4 Existing asphaltic BUR or mineral Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A Ashland Pliodeck, (Optional) Additional layers Ashland Pliodeck, Duro-Last / WB 1 -82.5 surface cap sheet 6-inch o.c of base insulation 6-inch o.c R-5. Existing asphaltic BUR or mineral Min. 2-inch ISO 95+ GL Ashland Pliodeck, Min. 0.25-inch SECUROCK Ashland Pliodeck, Duro-Last, Duro-Last EV or surface cap sheet 6-inch o.c. Gypsum -Fiber Roof Board 6-inch o.c. Duro-Tuff / SB IV or WB II 172.5 Existing asphaltic BUR or mineral (Optional) Min. 1.5-inch ACFoam II, Duro- R-6. surface cap sheet Guard ISO II -A Board -Max Min. 0.25-inch Dens Deck Board -Max Duro-Last / WB I -37.5 R 7 Existing asphaltic BUR or mineral Min. 1.5-inch ACFoam I1, Duro-Guard ISO II -A Board -Max (Optional) Additional layers Board -Max Duro-Last/SB I or WB II -45.0 surface cap sheet of base insulation R 8. Existing asphaltic BUR or mineral Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A Board -Max (Optional) Additional layers Board -Max Duro-Last, Duro-Last EV or 45.0 surface cap sheet of base insulation Duro-Tuff / 5B IV or WB II R 9 Existing asphaltic BUR or mineral Min. 1.5-inch ACFoam 11, Duro-Guard 150 11-A Board -Max (Optional) Additional layers Board -Max Duro-Last / WB 1 -82.5 surface cap sheet of base insulation R-10. Existing smooth surface BUR or Min. 0.25-inch SECUROCK Gypsum -Fiber Board -Max None N/A Duro-Last, Duro-Last EV or -245.0 granule surface modified bitumen Roof Board Duro-Tuff / SB IV or WB II R-11. Existing smooth surface BUR or Min. 1.5-inch ACFoam II, Duro-Guard ISO II- A, H-Shield, Duro-Guard ISO 11-H, ENRGY 3 or Board -Max Min. 0.25-inch SECUROCK Board -Max Duro-Last, Duro-Last EV or -247.5 granule surface modified bitumen g Duro-Guard ISO 11-G G Gypsum -Fiber Roof Board Duro-Tuff / SB IV or WB II Existing smooth -surface asphalt R-12. BUR or granule -surface modified Min. 0.75-inch Duro-Guard EPS Type IX Board -Max Min. 0.25-inch SECUROCK Board -Max Duro-Last, Duro-Last EV or -247.5 bitumen Gypsum -Fiber Roof Board Duro-Tuff / 5B IV or WB II Existing smooth -surface asphalt R-13. BUR or granule -surface modified Min. 0.75-inch Duro-Guard EPS Type IX Board -Max Min. 0.25-inch SECUROCK Board -Max Duro-Last, Duro-Last EV or -255.0 bitumen Gypsum -Fiber Roof Board Duro-Tuff / SB IV or WB II R-14. Existing asphaltic BUR or mineral (Optional) Min. 1.5-inch ACFoam II, Duro- CR-20 Min. 0.25-inch Dens Deck CR-20 Duro-Last / WB 1 -37.5 surface cap sheet Guard ISO II -A R 15. Existing asphaltic BUR or mineral Min. 1.5-inch ACFoam II, Duro-Guard I50 II -A CR 20 (Optional) Additional layers CR 20 Duro Last / SB I or WB II 45.0 surface cap sheet of base insulation R 16. Existing asphaltic BUR or mineral Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A CR-20 (Optional) Additional layers CR-20 Duro-Last, Duro-Last EV or 45.0 surface cap sheet of base insulation Duro-Tuff / SB IV or WB II NEMO ETC, LLC Certificate of Authorization #32455 ©2019 NEMO ETC, LLC 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Duro-Last Single Ply Roof Systems; (800) 248-0280 Evaluation Report D9750.05.08-1110 for FL1559-1113 Revision 10: 10/17/2019 Appendix 1, Page 36 of 44 ONEMOletc. TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A: BONDED INSULATION, BONDEDROOF COVER Base Insulation Layer Top Insulation Layer System Substrate MDP Type Attach Type Attach No. (Notes 1 & 12) Roof Cover (Note 16) (psf) (Notes 6 & 7) (Notes 6 & 7) R-17. Existing asphaltic BUR or mineral Min. 1.5-inch ACFoam 11, Duro-Guard 150 II -A CR-20 (Optional) Additional layers CR-20 Duro-Last / WB 1 -82.5 surface cap sheet of base insulation Existing smooth surface modified (Optional) Min. 1.5-inch ACFoam 11, Duro- Min. 0.25-inch SECUROCK Duro-Last, Duro-Last EV or R-18. bitumen Guard ISO II -A, H-Shield, Duro-Guard ISO II- CR-20 Gypsum -Fiber Roof Board CR-20 Duro-Tuff / SB IV or WB II 222 5 H, ENRGY 3 or Duro-Guard ISO II-G R-19. Existing smooth -surface 5135 Min. 0.75-inch Duro-Guard EPS Type 11, VIII Min. 0.25-inch SECUROCK Duro-Last, Duro-Last EV or modified bitumen or IX CR-20 Gypsum -Fiber Roof Board CR-20 Duro-Tuff / SB IV or WB II 222 5 R-20. Existing smooth surface BUR or Min. 0.25-inch SECUROCK Gypsum -Fiber CR-20 None N/A Duro-Last, Duro-Last EV or -245.0 granule surface modified bitumen Roof Board Duro-Tuff / SB IV or WB II Existing smooth surface BUR or Min. 1.5-inch ACFoam 11, Duro-Guard ISO II- Min. 0.25-inch SECUROCK Duro-Last, Duro-Last EV or R-21. granule surface modified bitumen A, H-Shield, Duro-Guard ISO II-H, ENRGY 3 or CR-20 Gypsum -Fiber Roof Board CR-20 Duro-Tuff / SB IV or WB II -247.5 Duro-Guard I5O II-G Existing smooth -surface asphalt R-22. BUR or granule -surface modified Min. 0.75-inch Duro-Guard EPS Type II, VIII CR-20 Min. 0.25-inch SECUROCK CR-20 Duro-Last, Duro-Last EV or 247 5 bitumen or IX Gypsum -Fiber Roof Board Duro-Tuff / SB IV or W8 II Existing smooth -surface asphalt R-23. BUR or granule -surface modified Min. 0.75-inch Duro-Guard EPS Type II, VIII CR-20 Min. 0.25-inch SECUROCK CR-20 Duro-Last, Duro-Last EV or -255.0 bitumen or IX Gypsum -Fiber Roof Board Duro-Tuff /SB IV or WB II R-24. Existing asphaltic BUR or mineral Min. 1.5-inch ACFoam II, Duro-Guard 150 II -A Hot asphalt (Optional) Additional layers Hot asphalt Duro-Last / SB I or WB II -45.0 surface cap sheet of base insulation R-25. Existing asphaltic BUR or mineral Min. 1.5-inch ACFoam 11, Duro-Guard I5O II -A Hot asphalt (Optional) Additional layers Hot asphalt Duro-Last, Duro-Last EV or -45.0 surface cap sheet of base insulation Duro-Tuff / 513 IV or WB II Existing asphaltic BUR or mineral (Optional) Additional layers R-26. surface cap sheet Min. 1.5-inch ACFoam 11, Duro-Guard ISO II -A Hot asphalt of base insulation Hot asphalt Duro-Last / WB 1 -75.0 Existing asphaltic BUR or mineral (Optional) Min. 1.5-inch ACFoam 11, Duro- R 27 surface cap sheet Guard ISO II -A Insta-Stik Min. 0.25-inch Dens Deck Insta-Stik Duro-Last / WB I -37.5 R 28 Existing asphaltic BUR or mineral Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A Insta-Stik (Optional) Additional layers Insta-Stik Duro-Last / SB 1 or WB II -45.0 surface cap sheet of base insulation R 29 Existing asphaltic BUR or mineral Min. 1.5-inch ACFoam 11, Duro-Guard ISO II -A Insta-Stik (Optional) Additional layers Insta-Stik Duro-Last, Duro-Last EV or -45.0 surface cap sheet of base insulation Duro-Tuff / 5B IV or WB II R-30. Existing asphaltic BUR or mineral Min. 1.5-inch ACFoam 11, Duro-Guard 150 II -A Insta-Stik (Optional) Additional layers Insta-Stik Duro-Last / WB 1 -82.5 surface cap sheet of base insulation Existing asphaltic BUR or mineral Min. 1.5-inch ACFoam 11, Duro-Guard 150 II- Min. 0.25-inch SECUROCK Duro-Last, Duro-Last EV or R-31. surface cap sheet A, H-Shield, Duro-Guard ISO II-H, ENRGY 3 or Insta-Stik Gypsum -Fiber Roof Board Insta-Stik Duro-Tuff / 513 IV or WB If -127.5 Duro-Guard ISO II-G NEMO ETC, LLC Evaluation Report D9750.05.08-1310 for FL3559-R33 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 37 of 44 ONEMO I etc. TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A: BONDED INSULATION, BONDED ROOF COVER Base Insulation Layer Top Insulation Layer System Substrate Roof Cover (Note 16) MDP Attach Attach No. (Notes 1 & 12) Type Type APO)(Notes 6 & 7) (Notes 6 & 7) R-32. Existing asphalt built-up roof (Optional) Min. 1.5-inch ACFoam 11, Duro- OlyBond 500 Min. 0.25-inch Dens Deck OlyBond 500 Duro-Last / WB 1 -37.5 Guard ISO II -A R-33. Existing asphalt built-up roof (Optional) Min. 1.5-inch ACFoam 11, Duro- OlyBond 500 (Optional) Additional layers OlyBond 500 Duro-Last / SB I or WB II 45.0 Guard ISO II -A of base insulation R-34. Existing asphalt built-up roof (Optional) Min. 1.5-inch ACFoam 11, Duro- OlyBond 500 (Optional) Additional layers OlyBond 500 Duro-Last, Duro-Last EV or -45.0 Guard ISO 11-A of base insulation Duro-Tuff / SB IV or WB II R-35. Existing asphalt built-up roof Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A OlyBond 500 (Optional) Additional layers OlyBond 500 Duro-Last / WB 1 -82.5 of base insulation (Optional) Min. 1.5-inch ACFoam II, Duro- Min. 0.25-inch SECUROCK Duro-Last, Duro-Last EV or R-36. Existing asphalt built-up roof Guard ISO II -A, H-Shield, Duro-Guard ISO 11- OlyBond 500 Gypsum -Fiber Roof Board OlyBond 500 Duro-Tuff / SB IV or WB II -120.0 H, ENRGY 3 or Duro-Guard ISO II-G DURO-FLEECE OR DURO-FLEECE PLUS MEMBRANE APPLICATIONS: R-37. Existing asphaltic BUR or mineral Min. 1.5-inch ACFoam 11, Duro-Guard ISO 11-A Ashland Pliodeck, (Optional) Additional layers Ashland Pliodeck, Duro-Fleece or Duro-Fleece -45.0 surface cap sheet 6-inch o.c of base insulation 6-inch o.c Plus / WB 11 Existing asphaltic BUR or mineral Ashland Pliodeck, Min. 0.25-inch SECUROCK Ashland Pliodeck, Duro-Fleece or Duro-Fleece R-38. surface cap sheet Min. 2-inch ISO 95+ GL 6-inch o.c. Gypsum -Fiber Roof Board 6-inch o.c. Plus / Duro-Fleece CR-20 -172.5 (splatter) or WB II R-39. Existing asphaltic BUR or mineral Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A Board -Max (Optional) Additional layers Board -Max Duro-Fleece or Duro-Fleece -45.0 surface cap sheet of base insulation Plus / WB II Existing smooth surface BUR or Min. 0.25-inch SECUROCK Gypsum -Fiber Duro-Fleece or Duro-Fleece R-40. granule surface modified bitumen Roof Board Board -Max None N/A Plus / Duro-Fleece CR-20 -245.0 (splatter) or WB 11 Existing smooth surface BUR or Min. 1.5-inch ACFoam 11, Duro-Guard ISO 11- Min. 0.25-inch SECUROCK Duro-Fleece or Duro-Fleece R-41. granule surface modified bitumen A, H-Shield, Duro-Guard ISO II-H, ENRGY 3 or Board -Max Gypsum -Fiber Roof Board Board -Max Plus / Duro-Fleece CR-20 -247.5 Duro-Guard ISO 11-G (splatter) or WB II Existing smooth -surface asphalt Min. 0.25-inch SECUROCK Duro-Fleece or Duro-Fleece R-42. BUR or granule -surface modified Min. 0.75-inch Duro-Guard EPS Type IX Board -Max Board -Max Plus / Duro-Fleece CR-20 -247.5 bitumen Gypsum -Fiber Roof Board (splatter) or WB II Existing smooth -surface asphalt Min. 0.25-inch SECUROCK Duro-Fleece or Duro-Fleece R-43. BUR or granule -surface modified Min. 0.75-inch Duro-Guard EPS Type IX Board -Max Board -Max Plus / Duro-Fleece CR-20 -255.0 bitumen Gypsum -Fiber Roof Board (splatter) or WB II R-44. Existing asphaltic BUR or mineral Min. 1.5-inch ACFoam 11, Duro-Guard ISO II -A CR-20 (Optional) Additional layers CR-20 Duro-Fleece or Duro-Fleece -45.0 surface cap sheet of base insulation Plus / WB II Existing smooth surface modified (Optional) Min. 1.5-inch ACFoam 11, Duro- Min. 0.25-inch SECUROCK Duro-Fleece or Duro-Fleece R-45. bitumen Guard ISO II -A, H-Shield, Duro-Guard 150 11- CR-20 Gypsum -Fiber Roof Board CR-20 Plus / Duro-Fleece CR-20 -222.5 H, ENRGY 3 or Duro-Guard ISO 11-G (splatter) or WB 11 NEMO ETC, LLC - Certificate of Authorization H32455 ©2019 NEMO ETC, LLC 6TM EDITION (2017) FBC NON-HVHZ EVALUATION Duro-Last Single Ply Roof Systems; (800) 248-0280 Evaluation Report D9750.05.08-1110 for FL1559-Ri3 Revision 10: 10/17/2019 Appendix 1, Page 38 of 44 ONEMOletc. TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A: BONDED INSULATION, BONDEDROOF COVER Base Insulation Layer Top Insulation Layer System Substrate MDP Type Attach Type Attach No. (Notes 1 & 12) Roof Cover (Note 16) (psf) (Notes 6 & 7) (Notes 6 & 7) Duro-Fleece or Duro-Fleece R-46. Existing smooth -surface SBS Min. 0.75-inch Duro-Guard EPS Type II, VIII CR-20 Min. 0.25-inch SECUROCK CR-20 Plus /Duro-Fleece CR-20 -222.5 modified bitumen or IX Gypsum -Fiber Roof Board (splatter) or WB II Existing smooth surface BUR or Min. 0.25-inch SECUROCK Gypsum -Fiber Duro-Fleece or Duro-Fleece R-47. CR-20 None N/A Plus / Duro-Fleece CR-20 -245.0 granule surface modified bitumen Roof Board (splatter) or WB II Existing smooth surface BUR or Min. 1.5-inch ACFoam II, Duro-Guard ISO II- Min. 0.25-inch SECUROCK Duro-Fleece or Duro-Fleece R-48. granule surface modified bitumen A, H-Shield, Duro-Guard ISO II-H, ENRGY 3 or CR-20 Gypsum -Fiber Roof Board CR-20 Plus / Duro-Fleece CR-20 -247.5 Duro-Guard ISO II-G (splatter) or WB II Existing smooth -surface asphalt Duro-Fleece or Duro-Fleece R-49. BUR or granule -surface modified Min. 0.75-inch Duro-Guard EPS Type II, VIII CR 20 Min. 0.25-inch SECUROCK CR-20 Plus / Duro-Fleece CR-20 -247.5 bitumen or IX Gypsum -Fiber Roof Board (splatter) or WB II Existing smooth -surface asphalt Duro-Fleece or Duro-Fleece R-50. BUR or granule -surface modified Min. 0.75-inch Duro-Guard EPS Type II, VIII CR 20 Min. 0.25-inch SECUROCK CR-20 Plus / Duro-Fleece CR-20 -255.0 bitumen or IX Gypsum -Fiber Roof Board (splatter) or WB II Existing asphaltic BUR or mineral (Optional) Additional layers Duro-Fleece or Duro-Fleece R-51. surface cap sheet Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A Hot asphalt of base insulation Hot asphalt Plus / WB II -45.0 R-52. Existing asphaltic BUR or mineral Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A Insta-Stik (Optional) Additional layers Insta-Stik Duro-Fleece or Duro-Fleece -45.0 surface cap sheet of base insulation Plus / WB II Existing asphaltic BUR or mineral Min. 1.5-inch ACFoam II, Duro-Guard ISO II- Min. 0.25-inch SECUROCK Duro-Fleece or Duro-Fleece R-53. surface cap sheet A, H-Shield, Duro-Guard ISO II-H, ENRGY 3 or Insta-Stik Gypsum -Fiber Roof Board Insta-Stik Plus / Duro-Fleece CR-20 -127.5 Duro-Guard ISO II-G (splatter) or WB II R-54. Existing asphalt built-up roof (Optional) Min. 1.5-inch ACFoam II, Duro- OlyBond 500 (Optional) Additional layers OlyBond 500 Duro-Fleece or Duro-Fleece -45.0 Guard ISO II -A of base insulation Plus / WB II (Optional) Min. 1.5-inch ACFoam II, Duro- Duro-Fleece or Duro-Fleece R-55. Existing asphalt built-up roof Guard ISO II -A, H-Shield, Duro-Guard ISO II- OlyBond 500 Min. 0.25-inch SECUROCK OlyBond 500 Plus / Duro-Fleece CR-20 -120.0 H, ENRGY 3 or Duro-Guard ISO II-G Gypsum -Fiber Roof Board (splatter) or WB II NEMO ETC, LLC Evaluation Report D9750.05.08-1110 for FL3559-1113 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 39 of 44 ONEMOletc. RECOVER OVER STEEL SUBSTRATE PLATE-BONDEDTABLE713: SYSTEM TYPE C-2- ROOF COVER (All areas where the existing metal panels do not lay flush on the underlying purlin shall have a 0.25-inch diameter pilot hole pre -drilled into the panel priorto driving the Purlin Fastener into the purlin.) System Substrate Attachment MDP Insulation Layer Roof Cover No. (Note 1) Fasteners (Note 11) Spacing (Psf) RHINOBOND INDUCTION WELD: Existing standing seam or lap seam metal roof covers One or more layers, any Trufast #12 Purlin Fasteners Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) R-56. having min. 16 gauge (0.0598 inch), 50 ksi or min. 12 gauge combination, with RHINOBOND Insulation 12-inch o.c. along or Duro-Tuff (min. 80-mil) induction welded to -30.0 (0.105 in.), 36 ksi steel purlins spaced max. 60-inch o.c. preliminarily fastened Plate (PVC) purlins 60-inch o.c. RHINOBOND Insulation Plate (PVC) using RHINOBOND Installation Tool Existing standing seam or lap seam metal roof covers One or more layers, any Trufast #12 Purlin Fasteners Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) R-57. having min. 16 gauge (0.0598 inch), 50 ksi or min. 12 gauge combination, with RHINOBOND Insulation 6-inch o.along . or Duro-Tuff (min.80-mil) induction welded to -45.0 (0.105 in.), 36 ksi steel purlins spaced max. 120-inch o.c. preliminarily fastened Plate (PVC) purlins 120-inch o.c. RHINOBOND Insulation Plate (PVC) using RHINOBOND Installation Tool Existing standing seam or lap seam metal roof covers One or more layers, any Trufast #12 Purlin Fasteners Duro-Last (min., 60 mil), Duro-Last EV (min. 50 mil) R-58. having min. 16 gauge (0.0598 inch), 50 ksi or min. 12 gauge combination, with RHINOBOND Insulation 12-inch o.c. along or Duro-Tuff (min. 80-mil) induction welded to -45.0 (0.105 in.), 36 ksi steel purlins spaced max. 48-inch o.c. preliminarily fastened Plate (PVC) purlins 48-inch D.C. RHINOBOND Insulation Plate (PVC) using RHINOBOND Installation Tool Existing standing seam or lap seam metal roof covers . One or more layers, any Trufast #12 Purlin Fasteners Duro-Last (min. 40-mil), Duro-Tuff (min. 50-mil) or R-59. having min. 16 gauge (0.0595 inch), 50 ksi or min. 12 gauge combination, with RHINOBOND Insulation 6-inch o.c. along Duro-Last EV (min. 50-mil) induction welded to -52.5 (0.105 in.), 36 ksi steel purlins spaced max. 72-inch o.c. preliminarily fastened Plate (PVC) purlins 72-inch o. RHINOBOND Insulation Plate (PVC) usingc. RHINOBOND Installation Tool Existing standing seam or lap seam metal roof covers One or more layers, any Trufast #12 Purlin Fasteners Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) R-60. having min. 16 gauge (0.0598 inch), 50 ksi or min. iZ gauge combination, with RHINOBOND Insulation 6-inch o.c. along or Duro-Tuff (min. 80-mil) induction welded to -52.5 (0.105 in.), 36 ksi steel purlins spaced max. 96-inch o.c. preliminarily fastened Plate (PVC) purlins 96-inch o. RHINOBOND Insulation Plate (PVC) usingc. RHINOBOND Installation Tool Existing standing seam or lap seam metal roof covers One or more layers, any Trufast #12 Purlin Fasteners Duro-Last (min. 40-mil), Duro-Tuff (min. 50-mil) or R-61. having min. 16 gauge (0.0598 inch), 50 ksi or min. 12 gauge combination, with RHINOBOND Insulation 6-inch D.C. along Duro-Last EV (min. 50-mil) induction welded to -82.5 0.105 in. , 36 ksi steel purlins spaced max. 48-inch o.c. ( ) p p preliminarily fastened Plate (PVC) purlins 48-inch o.c. RHINOBOND Insulation Plate (PVC) using RHINOBOND Installation Tool Existing standing seam or lap seam metal roof covers One or more layers, any Trufast #12 Purlin Fasteners Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) R-62. having min. 16 gauge (0.0598 inch), 50 ksi or min. 12 gauge combination, with RHINOBOND Insulation 6-inch o.c. along or Duro-Tuff (min. 80-mil) induction welded to -82.5 (0.105 in.), 36 ksi steel purlins spaced max. 60-inch o.c. preliminarily fastened Plate (PVC) purlins 60-inch o.c. RHINOBOND Insulation Plate (PVC) using RHINOBOND Installation Tool Existing standing seam or lap seam metal roof covers One or more layers, any Trufast #12 Purlin Fasteners Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) R-63. having min. 16 gauge (0.0598 inch), 50 ksi or min. 12 gauge combination, with RHINOBOND Insulation 6-inch o.c. along or Duro-Tuff (min. 80-mil) induction welded to -90.0 (0.105 in.), 36 ksi steel purlins spaced max.48-inch o.c. preliminarily fastened Plate (PVC) purlins 48-inch D.C. RHINOBOND Insulation Plate (PVC) using RHINOBOND Installation Tool ISOWELD INDUCTION WELD: Existing standing seam or lap seam metal roof covers One or more layers, any SFS Purlin Fastener with Duro-Last (min. 40 mil), Duro-Last EV (min. 50 mil) R-64. having min. 16 gauge (0.0598 inch), 50 ksi steel purlins combination, isoweld® Fl-P-6.8-PVC 12-inch D.C. along or Duro-Tuff (min. 50 mil) induction welded to SFS -45.0 spaced max. 60-inch o.c. preliminarily fastened Plates purlins 60-inch o.c. isoweld® Fi-P-6.8-PVC Plates with SFS isoweld® 3000 stand-up tool NEMO ETC, LLC Certificate of Authorization #32455 ©2019 NEMO ETC, LLC 6- EDITION (2017) FBC NON-HVHZ EVALUATION Duro-Last Single Ply Roof Systems; (800) 248-0280 Evaluation Report D9750.05.08-R10 for F1.3559-1313 Revision 10: 10/17/2019 Appendix 1, Page 40 of 44 ONEMOjetc. RECOVER OVER STEEL SUBSTRATE PLATE-BONDEDTABLE7B: SYSTEM TYPE C-2: ROOF COVER (All areas where the existing metal panels do not lay flush on the underlying purlin shall have a 015-inch diameter pilot hole pre -drilled into the panel prior to driving the Purlin Fastener into the purlin. System Substrate Attachment MDP Insulation Layer Roof Cover No. (Note 1) Fasteners (Note 11) Spacing (psf) Existing standing seam or lap seam metal roof covers One or more layers, any 5FS Purlin Fastener with Duro-Last (min. 40 mil), Duro-Last EV (min. 50 mil) R-65. having min. 16 gauge (0.0598 inch), 50 ksi steel purlins combination, isoweld® Fl-P-6.8-PVC 6-inch_o.c. along or Duro-Tuff (min. 50 mil) induction welded to SFS -90.0 spaced max. 60-inch o.c. preliminarily fastened Plates purlins 60-inch o.c. isoweld® Fl-P-6.8-PVC Plates with SFS isoweld® 3000 stand-up tool TRUFAST INDUCTION WELD: Existing standing seam or lap seam metal roof covers One or more layers, any Duro-Last (min. 40 mil), Duro-Last EV (min. 50 mil) R-66. having min. 16 gauge (0.0598 inch), 50 ksi or min. 12 gauge combination, Trufast #12 Purlin Fastener 12-inch o.c. along or Duro-Tuff (min. 50 mil) induction welded to -45.0 (0.105 in.), 36 ksi steel purlins spaced max. 60-inch o.c. preliminarily fastened with Trufast PVC IW Plate purlins 60-inch o.c. Trufast PVC IW Plates with Trufast Induction Welding Tool and Magnets Existing standing seam or lap seam metal roof covers One or more layers, any Trufast #12 Purlin Fastener 12-inch o.c. along Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) R-67. having min. 16 gauge (0.0598 inch), 50 ksi or min. 12 gauge combination, with Trufast PVC IW Plate purlins 48-inch o.c. induction welded to Trufast PVC IW Plates with -52.5 (0.105 in.), 36 ksi steel purlins spaced max. 48-inch o.c. preliminarily fastened Trufast Induction Welding Tool and Magnets Existing standing seam or lap seam metal roof covers One or more layers, any Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) R-68. having min. 16 gauge (0.0595 inch), 50 ksi or min. 12 gauge combination, Trufast #12 Purlin Fastener 12-inch o.c. along or Duro-Tuff (min. 60 mil) induction welded to -60.0 0.105 in. 36 ksi steel purlins spaced max. 48-inch o.c. ( ), p p preliminarily fastened with Trufast PVC IW Plate purlins 48-inch o.c. Trufast PVC IW Plates with Trufast Induction Welding Tool and Magnets Existing standing seam or lap seam metal roof covers One or more layers, any Trufast #12 Purlin Fastener 12-inch o.c. along Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) R-69. having min. 16 gauge (0.0598 inch), 50 ksi or min. 12 gauge combination, with Trufast PVC IW Plate purlins 36-inch o.c. induction welded to Trufast PVC IW Plates with -60.0 (0.105 in.), 36 ksi steel purlins spaced max. 36-inch o.c. preliminarily fastened Trufast Induction Welding Tool and Magnets Existing standing seam or lap seam metal roof covers One or more layers, any Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) R-70. having min. 16 gauge (0.0598 inch), 50 ksi or min. 12 gauge combination, Trufast #12 Purlin Fastener 12-inch o.c. along or Duro-Tuff (min. 60 mil) induction welded to -82.5 (0.105 in.), 36 ksi steel purlins spaced max. 36-inch o.c. preliminarily fastened with Trufast PVC IW Plate purlins 36-inch o.c. Trufast PVC IW Plates with Trufast Induction Welding Tool and Magnets Existing standing seam or lap seam metal roof covers One or more layers, any Trufast #12 Purlin Fastener 6-inch o.c. along Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) R-71. having min. 16 gauge (0.0598 inch), 50 ksi or min. 12 gauge combination, with Trufast PVC IW Plate purlins 72-inch o.c. induction welded to Trufast PVC IW Plates with -67.5 (0.105 in.), 36 ksi steel purlins spaced max. 72-inch o.c. preliminarily fastened Trufast Induction Welding Tool and Magnets Existing standing seam or lap seam metal roof covers One or more layers, any Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) R-72. having min. 16 gauge (0.0598 inch), 50 ksi or min. 12 gauge combination, Trufast #12 Purlin Fastener 6-inch o.c. along or Duro-Tuff (min. 60 mil) induction welded to -75.0 (0.105 in.), 36 ksi steel purlins spaced max. 72-inch o.c. preliminarily fastened with Trufast PVC IW Plate purlins 72-inch o.c. Trufast PVC IW Plates with Trufast Induction Welding Tool and Magnets Existing standing seam or lap seam metal roof covers One or more layers, any Trufast #12 Purlin Fastener 6-inch o.c. along Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) R-73. having min. 16 gauge (0.0598 inch), 50 ksi or min. 12 gauge combination, with Trufast PVC IW Plate purlins 60-inch o.c. induction welded to Trufast PVC IW Plates with -75.0 (0.105 in.), 36 ksi steel purlins spaced max. 60-inch o.c. preliminarily fastened Trufast Induction Welding Tool and Magnets Existing standing seam or lap seam metal roof covers One or more layers, any Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) R-74. having min. 16 gauge (0.0598 inch), 50 ksi or min. 12 gauge combination, Trufast #12 Purlin Fastener 6-inch o.c. along or Duro-Tuff (min. 60 mil) induction welded to -90.0 (0.105 in.), 36 ksi steel purlins spaced max. 60-inch o.c. preliminarily fastened with Trufast PVC IW Plate purlins 60-inch o.c. Trufast PVC IW Plates with Trufast Induction Welding Tool and Magnets NEMO ETC, LLC Evaluation Report D9750.05.08-1110 for FL1559-1113 Certificate of Authorization #32455 CH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 41 of 44 OMEMO I etc. RECOVER OVER STEEL SUBSTRATE PLATE-BONDEDTABLE713: SYSTEM TYPE C-2: ROOF COVER (All areas where the existing metal panels do not lay flush on the underlying purlin shall have a 0.25-inch diameter pilot hole pre -drilled into the panel priorto drivingthe Purlin Fastener into the purlin.) System Substrate Attachment Insulation Layer MDP Roof Cover No. (Note 1) Fasteners (Note 11) Spacing (psf) Existing standing seam or lap seam metal roof covers One or more layers, any Trufast #12 Purlin Fastener 6-inch o.c. along Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) R-75. having min. 16 gauge (0.0598 inch), 50 ksi or min. 12 gauge combination, with Trufast PVC IW Plate purlins 48-inch o.c. induction welded to Trufast PVC IW Plates with -90.0 (0.105 in.), 36 ksi steel purlins spaced max. 48-inch o.c. preliminarily fastened Trufast Induction Welding Tool and Magnets Existing standing seam or lap seam metal roof covers One or more layers, any Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) R-76. having min. 16 gauge (0.0598 inch), 50 ksi or min. 12 gauge combination, Trufast #12 Purlin Fastener 6-inch o.c. along or Duro-Tuff (min. 60 mil) induction welded to -112.5 (0.105 in.), 36 ksi steel purlins spaced max. 48-inch o.c. preliminarily fastened with Trufast PVC IW Plate purlins 48-inch o.c. Trufast PVC IW Plates with Trufast Induction Welding Tool and Magnets Existing standing seam or lap seam metal roof covers One or more layers, any Trufast #12 Purlin Fastener 6-inch o.c. along Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) R-77. having min. 16 gauge (0.0598 inch), 50 ksi or min. 12 gauge combination, with Trufast PVC IW Plate purlins 36-inch o.c. induction welded to Trufast PVC IW Plates with -112.5 (0.105 in.), 36 ksi steel purlins spaced max. 36-inch o.c. preliminarily fastened Trufast Induction Welding Tool and Magnets Existing standing seam or lap seam metal roof covers One or more layers, any Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) R-78. having min. 16 gauge (0.0598 inch), 50 ksi or min. 12 gauge combination, Trufast #12 Purlin Fastener 6-inch o.c. along or Duro-Tuff (min. 60 mil) induction welded to -150.0 (0.105 in.), 36 ksi steel purlins spaced max. 36-inch o.c. preliminarily fastened with Trufast PVC IW Plate purlins 36-inch o.c. Trufast PVC IW Plates with Trufast Induction Welding Tool and Magnets NEMO ETC, LLC Certificate of Authorization #32455 ©2019 NEMO ETC, LLC 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Duro-Last Single Ply Roof Systems; (800) 249-0280 Evaluation Report D9750.05.08-R10 for FL1559-1113 Revision 10: 10/17/2019 Appendix 1, Page 42 of 44 ONEMOletc. RECOVER OVER STEEL SUBSTRATE ATTACHEDTABLEX: SYSTEM TYPE D-1: PRELIMINARILY INSULATION, MECHANICALLY ATTACHED ROOF COVER (All areas where the existing metal panels do not lay flush on the underlying purlin shall have a 0.25-inch diameter pilot hole pre -drilled into the panel priorto driving the Purlin Fastener intothe purlin.) Insulation (Note 14) Roof Cover System Substrate MDP No. (Note 1) Type Attach Membrane Fasteners (Note 11) Attachment (psf) (Note 5) Standard Lao System fastened 12-inch Min. 22 ga., Type B, Grade 60 steel with One or more layers, any Duro-Tuff, Duro-Last #15 Extra Heavy Duty o.c. within 6-inch wide laps spaced R 79. existing single ply roof cover combination Prelim. attached min. 50 mil Drill Point Fastener with Duro-Last 114-inch o.c. Laps sealed with 1.5-inch -22.5 Poly -Plate heat weld. Min. 22 ga., Type B, Grade 60 steel with One or more layers, any Duro-Last, Duro-Last #15 Extra Heavy Duty Standard Lao System fastened 12-inch R-80. existing single ply roof cover combination Prelim. attached min. 40 mil Drill Point Fastener with Duro-Last o.c. within 3-inch wide tabs spaced 60- -30.0 Cleat Plates inch o.c. Min. 22 ga., Type B, Grade 60 steel with One or more layers, any Duro-Last, Duro-Last #15 Extra Heavy Duty Standard Lao System fastened 12-inch R-81. existing single ply roof cover combination Prelim. attached min. 40 mil Drill Point Fastener with Duro-Last o.c. within 6-inch wide tabs spaced -30.0 Cleat Plates 120-inch o.c. Existing standing seam or lap seam metal roof covers having min. 16 gauge (0.0598 One or more layers, any Duro-Last, Trufast #12 Purlin Fasteners with Standard Lao System fastened 9-inch R 82 inch), 50 ksi or min. 12 gauge (0.105 in.), 36 combination Prelim. attached min. 40 mil Duro-Last Poly -Plate o.c. within 3-inch wide tabs spaced 60- -45.0 ksi steel purlins spaced max. 120-inch o.c. inch o.c. along purlins Min. 0.5-inch DURO- Duro-Last #14 Heavy Type B Min. 22 ga., , Grade 40 steel with GUARD EPS FAN FOLD- Duty with Duro-Last 3- Duro-Last, Duro-Last #15 Extra Heavy Duty Standard Lao System fastened 12-inch R-83. existing asphalt built-up roof (BUR) inch inch Metal Plates; 1 per min. 40 mil Drill Point Fastener with Duro-Last c.c. within 3-inch wide tabs spaced 60- -52.5 5.3 ft'; 6 parts per 4x8 ft Poly -Plate or Duro-Last Cleat Plate inch o.c. GUARD XPS FAN GAN FOLD F section Min. 0.5-inch DURO- Duro-Last #14 Heavy Standard Lao System fastened 12-inch Min. 22 ga., Type B, Grade 40 steel with GUARD EPS FAN FOLD Duty with Duro-Last 3- Duro-Tuff, Duro-Last #15 Extra Heavy Duty o.c. within 6-inch wide laps spaced 54- R-84. existing asphalt built-up roof (BUR) or 3/8-inch DURO- inch Metal Plates; 1 per min. 50 mil Drill Point Fastener with Duro-Last inch o.c. Side laps sealed with 1.5-inch -52.5 5.3 ft ; 6 parts per 4x8 ft Poly -Plate or Duro-Last Cleat Plate GUARD XPS FAN FOLD heat -weld section NEMO ETC, LLC Evaluation Report D9750.05.08-1110 for F1.1559-1113 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 43 of 44 ONEMOjetc. RECOVERTABLE 7D: OVER CEIVIENTITIOUS WOOD FIBER SUBSTRATE SYSTEM TYPE E-1: NON -INSULATED, MECHANICALLY ATTACHED ROOF Roof Cover System Substrate (Note 1) Fasteners (Note 11) MDP No. Membrane Attach (psf) Type ENERFOAM Installation Min. 2-inch Tectum I Through-fastened 6-inch o.c. in rows 48-inch o.c. R-85. with existing single Duro-Last, Duro-Last Auger Fastener (min. 2- N/A -30.0 Fastener rows sealed with 10-inch wide strip of Duro- ply roof cover min. 40-mil inch embedment) Last, with a 1.5-inch heat weld on all sides Min. 3-inch Tectum I Auger Fastener (min. 2- 7/16-inch diameter x 2.5-inch deep pilot holt filled with Through -fastened 6-inch o.c. in rows 96-inch o.c. R-86. with existing single DurDuro-Last inch embedment) with 2" Auger Dupont ENERFOAM followed by fastener installation Fastener rows sealed with 10-inch wide strip of Duro- -67.5 ply roof cover _ mino-Last, min. 40-mil Plate and Dupont ENERFOAMT1 within 20-40 seconds after dispensing the foam Last, with a 1.5-inch heat weld on all sides RECOVERTABLE 7E: • System No. Substrate (Notes 1 & 12) Primer / Treatment Roof Cover (Note 16) MDP (psf) Existing asphaltic roof system with mechanically fastened and/or adhered Duro-Fleece or Duro-Fleece Plus / Duro-Fleece CR-20 (splatter R-87. underlying components (insulation, coverboard or base sheet) and with existing None applied) -150.0 granule -surface BUR or granule -surface SBS or APP modified bitumen cap sheet Existing asphaltic roof system with adhered underlying components (insulation, Duro-Fleece or Duro-Fleece Plus / Duro-Fleece CR-20 (splatter R-88. coverboard or base sheet) over monolithic deck and with existing smooth- or None applied) -370.0 granule -surface BUR or granule -surface SBS or APP modified bitumen cap sheet NEMO ETC, LLC Evaluation Report D9750.05.08-1110 for FL1559-R13 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION - Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 44 of 44