Loading...
HomeMy WebLinkAboutEvaluation Report; Roof SystemONEMOjetc. APPENDIX TABLE 1: ATTACHMENT REQUIREMENTS DECK FOR WIND UPLIFT RESISTANCE APPLICATION TYPE DESCRIPTION PAGE 1A Wood New, Reroof (Tear -Off) or Recover C-1 Mech. Attached Insulation, Bonded Roof Cover 4 1B Wood New, Reroof (Tear -Off) or Recover C-2 Mechanically Attached Insulation, Plate -Bonded Roof Cover 5-6 iC Wood New, Reroof (Tear -Off) or Recover D-1 Prelim. Attached Insulation, Mech. Attached Roof Cover 6-7 2A Steel New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 8 2B Steel or Structural Concrete New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 9 2C Steel or Structural Concrete New, Reroof (Tear -Off) or Recover C-1 Mech. Attached Insulation, Bonded Roof Cover 10-12 2D Steel New, Reroof (Tear -Off) or Recover C-2 Mechanically Attached Insulation, Plate -Bonded Roof Cover 13-17 2E Steel New, Reroof (Tear -Off) or Recover D-1 Prelim. Attached Insulation, Mech. Attached Roof Cover 18-19 2F Steel New or Reroof (Tear -Off) D-2 Thermal Barrier, Vapor Barrier, Prelim. Attached Insulation, Mech. Attached Roof Cover 20 3A Structural Concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 21-24 3B Structural Concrete New, Reroof (Tear -Off) or Recover C-2 Mechanically Attached Insulation, Plate -Bonded Roof Cover 25-28 3C Structural Concrete New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Roof Cover 28 3D Structural Concrete New, Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 29 4A Lightweight concrete / steel New or Reroof (Tear -Off) A-1 LWC to Steel Deck, Bonded Insulation, Bonded Roof Cover 30 4B Lightweight concrete / New or Reroof (Tear -Off) A-1 LWC to Structural Concrete Deck, Bonded Insulation, Bonded Roof Cover 30-32 4C Lightweight concrete / steel New or Reroof (Tear -Off) E-2 LWC to Steel Deck, Mechanically Attached Base Sheet, Bonded Roof Cover 33 4D Lightweight concrete / steel New or Reroof (Tear -Off) F LWC to Steel Deck, Bonded Roof Cover 33 4E Lightweight concrete / New or Reroof (Tear -Off) F LWC to Structural Concrete Deck / Bonded Roof Cover 33 5A Cementitious wood fiber Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 34 5B Cementitious wood fiber New, Reroof (Tear -Off) or Recover D-1 Prelim. Attached Insulation, Mech. Attached Roof Cover 34 SC Cementitious wood fiber New, Reroof (Tear -Off) or Recover E-1 Non -insulated, Mech. Attached Roof Cover 34 6A Gypsum Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 35 6B Gypsum Reroof (Tear -Off) or Recover D-1 Prelim. Attached Insulation, Mech. Attached Roof Cover 35 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 36-39 7B Steel Recover C-2 Mechanically Attached Insulation, Plate -Bonded Roof Cover 40-42 7C Steel Recover D-1 Insulated, Mechanically Attached Roof Cover 43 7D Cementitious wood fiber Recover E-1 Non -insulated, Mech. Attached Roof Cover 44 7E Various Recover F Non -Insulated, Bonded Roof Cover 44 The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Unless otherwise noted, fasteners and stress plates for insulation attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements: ➢ Wood Deck: Duro-Last #14 HD Fasteners and Duro-Last 3-inch Metal Plates. Min. %-inch plywood penetration or minimum 1-inch wood plank embedment. ➢ Steel Deck: Duro-Last #14 HD or #15 Extra Heavy Duty Drill Point Fasteners and Duro-Last 3-inch Metal Plates. Minimum %-inch steel penetration, engage the top flute of the steel deck. ➢ Structural Concrete: Duro-Last #14 HD Fasteners, Duro-Last Concrete Screws or Duro-Last Fluted Concrete Nails and Duro-Last 3-inch Metal Plates. Minimum 1-inch embedment. Fasteners installed with a pilot hole in accordance with the fastener manufacturer's published installation instructions. 3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanu rate, polystyrene, fiberboard, perlite and/or gypsum -based insulation board that meets the QA requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. NEMO ETC, LLC Evaluation Report D9750.05.08-1110 for FL1559-1113 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 1 of 44 ONEMOletc. Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type C-2 (plate bonded roof cover) or Type D-1 (mechanically attached roof cover), whereby the membrane fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater type, thickness and strength to the steel and concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5. Preliminary insulation attachment for System Type D-1: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (January 2016) 6. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published instructions. ➢ Ashland Pliodeck: Continuous % to %-inch wide ribbons, 12-inch o.c. Ribbons for subsequent layer(s) shall be run perpendicular to those for the underlying layer. ➢ Duro-Grip Board -Max: Continuous 3-inch ribbons, 12-inch o.c. ➢ Duro-Grip CR-20: Continuous 2% to 3'/:-inch ribbons, 12-inch o.c. ➢ Duro-Grip Insta-Stik: Continuous Y. to 1-inch wide ribbons, 12-inch o.c. ➢ Duro-Grip OlyBond 500: Continuous Y. to 1-inch wide ribbons, 12-inch o.c. using PaceCart, SpotShot or Cansiter. ➢ Duro-Grip WeatherTite One Step Adhesive (WT OSA): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c. ➢ Hot asphalt: Full mopping, 25-30lbs/square. ➢ OMG OlyBond Classic: Continuous %-inch ribbons, 12-inch o.c. or full -coverage ➢ Trufast Roofing Adhesive: Continuous Y. to 1-inch wide ribbons, 12-inch o.c. ➢ Note: When multiple loyers(s) of insulation and/or coverboard are installed in ribbon -applied adhesive, boards shall be staggered from layer -to -layer. ➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 7. Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to 'increase' the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table: ➢ Duro-Grip CR-20: MDP = -117.5 psf (Min. 1.0-inch thick) ➢ Duro-Grip OlyBond 500: MDP = -315.0 psf (Min. 0.5-inch thick H-Shield, Duro-Guard ISO II-H, ENRGY 3 or Duro-Guard ISO II-G) ➢ Duro-Grip OlyBond 500: MDP = -487.5 psf (Min. 0.5-inch thick ACFoam II or Duro-Guard ISO II -A) ➢ Duro-Grip WeatherTite One Step Adhesive (WT OSA): MDP -157.5 psf (Min. 0.5-inch thick) 8. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft. 9. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 10. For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted. 11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 12. For existing substrates in a bonded recover or re -roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13. For System Type D-1, steel deck applications, the roof membrane shall be run with its length perpendicular to the steel deck flutes. 14. For Structural Concrete Deck or Recover Applications using System Type C-2 (Plate Bonded Roof Cover) or Type D-1 (Mechanically Attached Roof Cover), the insulation is optional. Alternatively, Dens Deck, Dens Deck Prime, SECUROCK Gypsum -Fiber Roof Board, SECUROCK Glass -Mat Roof Board, Duro-Blue'", Duro-Weave'"", Duro-Last Geotextile Slip Sheet, Duro-Fold" or Ultra-Fold®TPM may be used as a separation layer. Board NEMO ETC, LLC Evaluation Report D9750.05.08-1110 for F1.3559-1133 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 2 of 44 ONEMOjetc. products should be preliminarily attached prior to roof cover installation. The existing roof system shall be suitable for a recover application. The separator component shall be documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover in Recover applications. 15. Lightweight Insulating Concrete (LWC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced, refer to current LWC Product Approval for specific deck construction and limitations. Unless otherwise noted, for systems where specific LWC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top -coat thickness is 2-inches. For LWC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. For "pre-existent' LWC references, listings were established through testing over lightweight concrete cast using only foaming agent (ASTM C896), water and Portland cement (ASTM C150), with no proprietary additives, in accordance with procedures adopted by Miami -Dade BCCO (FBC CER1592). Unless otherwise noted, use of these listings in new construction or re -roof (tear -off) applications is at the discretion of the Designer of Record and Authority Having Jurisdiction. 16. For adhered membrane systems, side laps shall be minimum 3-inch wide sealed with min. 1.5-inch heat weld. Membrane adhesive application rates are as follows: MEMBRANE . •.ROOF ADHESIVE COVERJ ADHESIVE COMB.INATIONS APPLICATION RATE Duro-Last Duro-Last SB I Contact 1.5 gal/sq./surface Duro-Last, Duro-Last EV or Duro-Tuff Duro-Last SB IV Contact 1.67 gal/sq./surface Duro-Last Duro-Last WB I Contact 0.5 gal/sq./surface Duro-Last, Duro-Last EV or Duro-Tuff Duro-Last WB II Substrate only 0.7 gal/sq. Duro-Fleece or Duro-Fleece Plus Duro-Last WB 11 Substrate only 1.0 gal/sq. Duro-Fleece or Duro-Fleece Plus Duro-Fleece Adhesive Substrate only Continuous %-inch wide ribbons, 6-inch o.c. Duro-Fleece or Duro-Fleece Plus Duro-Fleece CR-20 Membrane Adhesive Substrate only Splatter -applied, full coverage per Duro-Last instructions Duro-Fleece or Duro-Fleece Plus Trufast Roofing Adhesive Substrate only Continuous % to 1-inch wide ribbons, 4-inch o.c., resulting in full -coverage 17. Vapor barrier options for use over structural concrete deck followed by adhesive -applied insulation carry the following Maximum Design Pressure (MDP) limitations. The lesser of the MOP listings below vs. those in Table 3A applies. Option # Primer VAPOR BARRIER OPTIONS; STRUCTURAL CONCRETE DECK; FOLLOWED By ADHESIVE -APPLIED INSULATION PER TABLE 3A: Vapor Barrier Insulation Adhesive Type Application MDP (psf) VB-1. ASTM D41 Duro-Last Torch Down Vapor Barrier torch -applied Board -Max, 12-inch o.c. -37.5 VB-2. ASTM D41 Duro-Last Torch Down Vapor Barrier torch -applied OlyBond 500, 12-inch o.c. -382.5 VB-3. ASTM D41 Duro-Last Torch Down Vapor Barrier torch -applied Trufast Roofing Adhesive, 12-inch o.c. -180.0 VB-4. ASTM D41 Duro-Last Torch Down Vapor Barrier torch -applied WeatherTite One Step Adhesive, 12-inch o.c. -270.0 V131-5. Duro-Last VB Primer Duro-Last Vapor Barrier self -adhering Board -Max, 12-inch o.c. -37.5 VB-6. Duro-Last VB Primer Duro-Last Vapor Barrier self -adhering OlyBond 500, 12-inch o.c. -187.5 VB-7. Duro-Last VB Primer Duro-Last Vapor Barrier self -adhering Trufast Roofing Adhesive, 12-inch o.c. -390.0 VB-8. Duro-Last VB Primer Duro-Last Vapor Barrier self -adhering WeatherTite One Step Adhesive, 12-inch o.c. -172.5 18. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind pressures. NEMO ETC, LLC Certificate of Authorization #32455 ©2019 NEMO ETC, LLC 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Duro-Last Single Ply Roof Systems; (800) 248-0280 Evaluation Report D9750.05.08-1310 for FL1559-1113 Revision 10: 10/17/2019 Appendix 1, Page 3 of 44 ONEMOIetc. 1A: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) oR RECOVER ATTACHEDTABLE SYSTEM TYPE C-1: MECHANICALLY INSULATION,BONDED ROOFCOVER System Top Insulation Layer No. Deck (Note 1) Base Insulation Layer Roof Cover (Note 16) MDP (psf) Type Fasteners Attach W 1 Min. 2-inch T&G lumber or min. % (Optional) One or more Min. 0.25-inch Dens Deck or Dens Deck Note 2 1 per 2.67 ft' Duro-Last / SB I or WB II -30.0* inch exterior grade plywood layers, any combination Prime W 2 Min. 2-inch T&G lumber or min. '/<- (Optional) One or more Min. Y2-inch Dens Deck or Dens Deck Note 2 1 per 3.2 ft' Duro-Last / SB I or WB II -30.0* inch exterior grade plywood layers, any combination Prime W 3 Min. 2-inch T&G lumber or min. %- (Optional) One or more Min. 5/8-inch Dens Deck or Dens Deck Note 2 1 per 4 ft' Duro-Last / SB 1 or WB II -30.0* inch exterior grade plywood layers, any combination Prime W 4 Min. 2-inch T&G lumber or min. %- (Optional) One or more Min. 1.5-inch ACFoam II, Duro-Guard Note 2 1 per 2 ft' Duro-Last / WB 1 -45.0* inch exterior grade plywood layers, any combination ISO II -A Min. 2-inch T&G lumber or min. %- (Optional) One or more Min. 1.5-inch ACFoam 11, Duro-Guard W 5. inch exterior grade plywood layers, any combination ISO II -A or ACFoam III, Duro-Guard ISO Note 2 1 per 4 ft2 Duro-Last / SB 1 -45.0* III -A W 6 Min. 2-inch T&G lumber or min. '/<- (Optional) One or more Min. 1.5-inch ACFoam III, Duro-Guard Note 2 1 per 4 ft' Duro-Last / WB 1 -45.0* inch exterior grade plywood layers, any combination ISO III -A W 7 Min. 2-inch T&G lumber or min. %- (Optional) One or more Min. 0.25-inch Dens Deck or Dens Deck Note 2 1 per 2 ftZ Duro-Last / SB I or WB II -45.0* inch exterior grade plywood layers, any combination Prime NEMO ETC, LLC Evaluation Report D9750.05.08-1110 for FL3559-1133 Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 4 of 44 ONEMOjetc. TABLE 113: .... .. .. RECOVER SYSTEM TYPE C-2: MECHANICALLY ATTACHED INSULATION, :... ROOF COVER System Deck Insulation Layer Attach MDP Roof Cover /Attach I (Note 1) (Note 14) Fasteners Density (psf) RHINOBOND INDuaION WELD: Duro-Last (min. 60 mil), Duro-Last EV Min. 19/32-inch (Optional) One or more Duro-Last #14 HD (min. 50 mil) or Duro-Tuff (min. 80-mil) W-8. plywood at max. layers, any combination; with Fasteners inch o.c. in rows spaced inch positioned atop wood induction welded to RHINOBOND -37.5 24-inch spans preliminarily attached Insulation Plate (PVC; tion Plate b nto.i trusses; minimum 0.9-inch fastener embedment into trusses minimum Insulation Plate (PVC) using RHINOBOND Installation Tool Duro-Last #14 HD Duro-Last (min. 60 mil), Duro-Last EV Min. 19/32-inch (Optional) One or more with RHINOBOND Fasteners 18-inch o.c. in rows spaced 48-inch o.c. positioned atop wood (min. 50 mil) or Duro-Tuff (min. 80-mil) W-9. plywood at max. layers, any combination; Insulation Plate trusses; minimum 0.9-inch fastener embedment into trusses induction welded to RHINOBOND -37.5 24-inch spans preliminarily attached (PVC) Insulation Plate (PVC) using RHINOBOND Installation Tool Duro-Last (min. 60 mil) , Duro-Last EV Min. 19/32-inch (Optional) One or more Duro-Last#14 HD (min. 50 mil) or Duro-Tuff (min. 80-mil) W-10. plywood at max. layers, any combination; with Fasteners inch o.c. in rows spaced inch positioned atop wood induction welded to RHINOBOND -52.5 24-inch spans preliminarily attached InsulationPlate `PVCj tion Plate minimum nto.i trusses; minimum 0.9 inch fastener embedment into trusses b Insulation Plate (PVC) using RHINOBOND Installation Tool Duro-Last (min. 60 mill, Duro-Last EV Min. 19/32-inch (Optional) One or more Duro-Last #14 HD (min. 50 mil) or Duro-Tuff (min. 80-mil) W-11. plywood at max. layers, any combination; with RHINOBOND Fasteners 6-inch o.c. in rows spaced 96-inch o.c. positioned atop wood trusses; induction welded to RHINOBOND -60.0 24-inch spans preliminarily attached Insulation Plate minimum 0.9-inch fastener embedment into trusses Insulation Plate (PVC) using (PVC) RHINOBOND Installation Tool 1 per 2.67 ftz z' z+• za• za' �z' (12 parts per 4 O O O OO Duro-Last #14 HD x 8 ft bird; Duro-Last (min. 40 mil), Duro-Tuff Min. 19/32-inch One or more layers, any with RHINOBOND Fasteners (min. 50 mil) or Duro-Last EV (min. 50- W-12. plywood at max. combination; min. 1.5- Insulation Plate engage wood O OO O O mil) induction welded to RHINOBOND -60.0 24-inch spans inch, min. 16 psi (PVC) trusses, Insulation Plate (PVC) using minimum 0.9- RHINOBOND Installation Tool inch O OO O O embedment) NEMO ETC, LLC Certificate of Authorization #32455 ©2019 NEMO ETC, LLC 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Duro-Last Single Ply Roof Systems; (800) 248-0280 Evaluation Report D9750.05.08-R10 for FI.1559-1133 Revision 10: 10/17/2019 Appendix 1, Page 5 of 44 ONEMOjetc. TABLE 1B: ••r rCONSTRUCTION,.. . OR RECOVER PLATE-BONDEDSYSTEM TYPE C-2: MECHANICALLY ATTACHED INSULATION, ROOF COVER System Deck Insulation Layer Attach MDP No. (Note 1) (Note 14) Roof Cover /Attach (psf) Fasteners Density 1 per 2 ft2 12' 24'- 24' 24• 12' (16 parts per 4 O O O O Duro-Last #14 HD x 8 ft brd; Duro-Last (min. 40 mil), Duro-Tuff Min. 19/32-inch One or more layers, any with RHINOBOND Fasteners O O O O (min. 50 mil) or Duro-Last EV (min. 50- W-13. plywood at max. combination; min. 1.5- engage wood mil) induction welded to RHINOBOND -90.0 24-inch spans inch, min. 16 psi Insulation Plate (PVC) trusses, O O O p Insulation Plate (PVC) using minimum 0.9- N RHINOBOND Installation Tool inch embedment) O O O O TABLE 1C: ••r rCONSTRUCTION,••• • OR RECOVER SYSTEMITYPED-1:r INSULATION,r ROOF COVER Insulation (Note 14) Roof Cover System Deck (Note 1) MDP Attach No. Type Membrane Fasteners Attach (psf) (Note 5) STANDAADLAP SysTEMS: Min. 0.5-inch Duro-Guard EPS Fan Fold and/or min. Duro-Last #15 Extra Heavy Duty W 14. rated CDX pinchlyw000dd at plywooda 1-inch Duro-Guard ISO II-H, Duro-Guard ISO II- Prelim. Duro-Last, Drill Point Fasteners and Duro- Standard Lap System fastened 12-inch o.c. 30.0 max. 32-i spans G, Duro-Guard ISO II -A, Duro-Guard ISO III-H or attached min. 40-mil Last Poly -Plates or Duro-Last within 6-inch wide tabs spaced 58-inch o.c. Duro-Guard 150 III -A Cleat Plates Min. 19/32-inch APA 0.5-inch Duro-Guard EPS Fan Fold and/or min. Duro-Last #15 Extra Heavy Duty Standard Lap System fastened 12-inch o.c. W-15. rated CDX plywood at 1-inch Duro-Guard ISO II-H, Duro-Guard 150 II- Prelim. Duro-Last EV, Drill Point Fasteners and Duro- within 6-inch wide laps spaced 54-inch o.c. -30.0 max. 32-inch spans G, Duro-Guard ISO II -A, Duro-Guard ISO III-H or attached min. 50-mil Last Poly -Plates or Duro-Last Lap sealed with 1.5-inch heat weld Duro-Guard ISO III -A Cleat Plates Min. 19/32-inch APA 0.5-inch Duro-Guard EPS Fan Fold and/or min. Duro-Last #15 Extra Heavy Duty Standard Lap System fastened 12-inch o.c. W-16. rated CDX plywood at 1-inch Duro-Guard ISO II-H, Duro-Guard ISO II- Prelim. Duro-Tuff, Drill Point Fasteners Duro-Last within 6-inch wide laps spaced 54-inch o.c. -30.0 max. 32-inch spans G, Duro-Guard I50 II -A, Duro-Guard I50 III-H or attached min. 50-mil Cleat Plates Lap sealed with 1.5-inch heat weld Duro-Guard ISO III -A Min. 19/32-inch APA 0.5-inch Duro-Guard EPS Fan Fold and/or min. Duro-Last #15 Extra Heavy Duty Standard Lap System fastened 6-inch o.c. W-17. rated CDX plywood at 1-inch Duro-Guard ISO II-H, Duro-Guard ISO II- Prelim. Duro-Last EV, Drill Point Fasteners and Duro- within 6-inch wide laps spaced inch 37.5 max. 32-inch spans G, Duro-Guard ISO II -A, Duro-Guard ISO III-H or attached min. 50-mil Last Poly -Plates or Duro-Last o.c. Lap sealed with 1.5-inch heaatt weld Duro-Guard ISO III -A Cleat Plates Min. 19/32-inch APA 0.5-inch Duro-Guard EPS Fan Fold and/or min. Duro-Last #15 Extra Heavy Duty Standard Lap System fastened 6-inch o.c. W-18. rated CDX plywood at 1-inch Duro-Guard ISO II-H, Duro-Guard ISO II- Prelim. Duro-Tuff, Drill Point Fasteners and Duro- within 6-inch wide laps spaced 114-inch -37.5 max. 32-inch spans G, Duro-Guard ISO II -A, Duro-Guard ISO III-H or attached min. 50-mil Last Cleat Plates o.c. Lap sealed with 1.5-inch heat weld Duro-Guard I50 III -A NEMO ETC, LLC Evaluation Report D9750.05.08-1110 for FL1559-R13 Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 6 of 44 ONEMOjetc. TABLE IC: ....REROOF (TEAR -OFF) OR RECOVER ATTACHEDSYSTEM TYPE D-1: PRELIMINARILY ATTACHED INSULATION, MECHANICALLY ROOF COVER Insulation (Note 14) Roof Cover System Deck (Note 1) Attach MDP No. Type Membrane Fasteners Attach (psf) (Note 5) Duro-Last #15 Extra Heavy Duty Standard Lao System fastened 6-inch o.c. W-19. Min. 19/32-inch plywood (Optional) One or more layers, any combination Prelim. Duro-Last, Drill Point Fasteners and Duro- within 6-inch wide tabs spaced 57-inch o.c. -52.5 at max. 24-inch spans attached min. 40 mil Last 2.4-inch Barbed Metal Plate Screws located 2.7-inches from tab edge 0.5-inch Duro-Guard EPS Fan Fold and/or min. Duro-Last #15 Extra Heavy Duty Min. 19/32-inch APA 1-inch Duro-Guard ISO II-H, Duro-Guard ISO II- Prelim. Duro-Last, Drill Point Fasteners and Duro- Standard Lao System fastened 6-inch o.c. W-Z0. rated plywood at G, Duro-Guard ISO II -A, Duro-Guard 150 III-H or attached min. 40-mil Last Poly -Plates or Duro-Last within 6-inch wide tabs spaced 58-inch o.c. 52.5 max. 32-i-inch spans Duro-Guard ISO III -A Cleat Plates Min. 19/32-inch APA 0.5-inch Duro-Guard EPS Fan Fold and/or min. Duro-Last #15 Extra Heavy Duty Standard Lap System fastened 6-inch o.c. W-21. rated CDX plywood at 1-inch Duro-Guard ISO 11-H, Duro-Guard ISO Ik Prelim. Duro-Last EV, Drill Point Fasteners and Duro- within inch wide laps spaced 54-inch o.c. 52.5 max. 32-inch spans G, Duro-Guard ISO II -A, Duro-Guard ISO III-H or attached min. 50-mil Last Poly -Plates or Duro-Last Lap sealed with 1.5-inch heat weld Duro-Guard I50 III -A Cleat Plates Min. 19/32-inch APA 0.5-inch Duro-Guard EPS Fan Fold and/or min. Duro-Last #15 Extra Heavy Duty Standard Lao System fastened 6-inch o.c. W-22. rated CDX plywood at 1-inch Duro-Guard ISO II-H, Duro-Guard ISO II- Prelim. Duro-Tuff, Drill Point Fasteners and Duro- within 6-inch wide laps spaced 54-inch o.c. -52.5 max. 32-inch spans G, Duro-Guard I50 II -A, Duro-Guard I50 III-H or attached min. 50-mil Last Cleat Plates Lap sealed with 1.5-inch heat weld Duro-Guard ISO III -A DURo-ROOF LAP SYSTEMS: - Min. 19/32-inch plywood Prelim. Duro-Last, Duro-Last #14 HD Fasteners with Duro-Roof Lap System fastened 6-inch o.c. W 23. at max. 24-inch spans (Optional) One or more layers, any combination attached min. 40 mil Duro-Last 3-inch Metal Plates within 6-inch wide tabs spaced 57-inch o.c. -52.5 Tab Sealer 4725 at max. 60 ft2/gal. Nominal 1 x 6 —inch T&G Duro-Last #15 Extra Heavy Duty Duro-Roof Lap System fastened 6-inch o.c. W-24. board decking attached One or more layers, any combination, min. 1.5- Prelim. Duro-Last, Drill Point Fasteners with OMG 2- within 6-inch wide tabs spaced 25-inch o.c. -97.5 per FBC Section 2322.2.2 inch 1 Attached min. 40 mil 1 1 3/8" Eyehook Plates Tab Sealer 4725 at max. 60 ft2/gal. NEMO ETC, LLC Certificate of Authorization #32455 02019 NEMO ETC, LLC 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Duro-Last Single Ply Roof Systems; (800) 248-0280 Evaluation Report D9750.05.08-1310 for F1.1559-1133 Revision 10: 10/17/2019 Appendix 1, Page 7 of 44 ONEMOletc. TABLE 2A: STEEL DECKS - NEW CONSTRUCTION .. REROOF SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System Deck Base Insulation Layer Top Insulation Layer MDP No. (Note 1) Attach (Notes 6 & 7) Type Type Attach (Notes 6 & 7) Roof Cover (Note 16) (psf) BAREBACK MEMBRANE APPLICATIONS: 5-1. 22 ga., Type B, Min. 1.5-inch Duro-Guard I50 II-H WT OSA, 12-inch o.c. (every- Min. 0.25-inch DEXcell FA Glass Mat WT OSA Duro-Last, Duro-Last EV 75.0 Grade 60 steel other deck flange) Roof Board or Duro-Tuff / 5B IV 5 2. 22 ga., Type B, Min. 1.5-inch Duro-Guard ISO II-H WT OSA, 12-inch o.c. (every- (Optional) Additional layer(s) base WT 05A Duro-Last, Duro-Last EV 82.5 Grade 60 steel other deck flange) insulation or Duro-Tuff / 5B IV S-3. 22 ga., Type B, Min. 1.5-inch Duro-Guard I50 II-H WT OSA, 12-inch o.c. (every- Min. 0.25-inch DEXcell FA Glass Mat WT OSA Duro-Last, Duro-Last EV 75.0 Grade 60 steel other deck flange) Roof Board or Duro-Tuff / WB II S-4. 22 ga., Type e, . . Min15-inch Duro-Guard ISO II-H WT OSA, 12-inch o.c. (every- (Optional) Additional layer(s) base WT OSA Duro-Last, Duro-Last EV 82.5 Grade 60 steel other deck flange) insulation or Duro-Tuff / WB II DURO-FLEECE OR DUROrFLEECEPLUS MEMBRANE APPLICATIONS: 5-5. 22 ga., Type B, . . Min15-inch Duro-Guard ISO II-H WT OSA, 12-inch o.c. (every- Min. 0.25-inch DEXcell FA Glass Mat WT OSA Duro-Fleece CR-20 75.0 Grade 60 steel other deck flange) Roof Board (splatter applied) S-6. 22 ga., Type B, Min. 1.5-inch Duro-Guard ISO II-H WT OSA, 12-inch o.c. (every- (Optional) Additional layer(s) base WT OSA Duro-Fleece CR-20 82.5 Grade 60 steel other deck flange) g) insulation (splatter applied) 5 7. 22 ga., Type B, . . Min15-inch Duro-Guard ISO II-H WT OSA, 12-inch o.c. (every- Min. 0.25-inch DEXcell FA Glass Mat WT OSA Duro-Fleece or Duro- 75.0 Grade 60 steel other deck flange) Roof Board Fleece Plus / WB II S 8. 22 ga., Type B, Min. 1.5-inch Duro-Guard ISO II-H WT OSA, 12-inch o.c. (every- (Optional) Additional layer(s) base WT OSA Duro-Fleece or Duro- 82.5 Grade 60 steel other deck flange) insulation Fleece Plus / WB II NEMO ETC, LLC Evaluation Report 139750.05.08-1110 for FL1559-R13 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEW ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 8 of 44 ONEMOjetc. TABLE 213: STEEL OR •.. .. RECOVER SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System Deck Base Insulation Layer Top Insulation Layer MDP No. (Note 1) Type Fasteners Attach Type Attach (Notes 6 & 7) Roof Cover (Note 16) (psf) BAREBACK MEMBRANE APPLICATIONS: Min. 22 ga., Type B, Min. 2-inch ACFoam II, Duro-Guard Min. 0.25-inch SECUROCK Hot asphalt or Board -Max, Duro-Last, Duro-Last S-9. Grade 33 steel or ISO II -A, H-Shield, Duro-Guard ISO II- Note 2 1 per 4 ft2 Gypsum -Fiber Roof Board CR-20, Insta-Stik or Trufast EV or Duro-Tuff / 5B IV -37.5* structural concrete H, ENRGY 3 or Duro-Guard ISO II-G Roofing Adhesive or WB II Min. 22 ga., Type B, Min. 2-inch ACFoam II, Duro-Guard Min. 0.25-inch SECUROCK Hot asphalt or Board -Max, Duro-Last, Duro-Last 5-10. Grade 33 steel or ISO II -A, H-Shield, Duro-Guard ISO ll- Note 2 1 per 2.67 ft2 Gypsum -Fiber Roof Board CR-20, Insta-Stik or Trufast EV or Duro-Tuff / 513 IV -45.0* structural concrete H, ENRGY 3 or Duro-Guard ISO II-G Roofing Adhesive or WB II Min. 22 ga., Type B, Min. 2-inch ACFoam II, Duro-Guard Min. Hot asphalt or Board -Max, Duro-Last, Duro-Last S-11. Grade 33 steel or ISO II -A, H-Shield, Duro-Guard ISO II- Note 2 1 per 1.33 ft2 um -Finch Roof BoardROCK Gypsum -Fiber Roof Board CR-20, Insta-Stik or Trufast EV or Duro-Tuff/ 5B IV -60.0 structural concrete H, ENRGY 3 or Duro-Guard ISO II-G Roofing Adhesive, 6-inch o.c. or WB II DURo-FLEECE OR DURO-FLEECE PLUS MEMBRANE APPLICATIONS: Min. 22 ga., Type B, Min. 2-inch ACFoam II, Duro-Guard Hot asphalt or Board -Max, Duro-Fleece or Duro- 5-12. Grade 33 steel or ISO II -A, H-Shield, Duro-Guard ISO II- Note 2 1 per 4 ft2 Min. 0.25-inch SECUROCK CR-20, Insta-Stik or Trufast Fleece Plus / Duro- 37 5* structural concrete H, ENRGY 3 or Duro-Guard ISO II-G Gypsum -Fiber Roof Board Roofing Adhesive, 6-inch o.c. Fleece CR-20 (splatter applied) or WB II Min. 22 ga., Type B, Min. 2-inch ACFoam II, Duro-Guard Hot asphalt or Board -Max, Duro-Fleece or Duro- 5-13. Grade 33 steel or ISO II -A, H-Shield, Duro-Guard ISO II- Note 2 1 per 2.67 ft2 Min. Min. 0.25-inch SECUROCK CR-20, Insta-Stik or Trufast Fleece Plus / Duro- -45.0* structural concrete H, ENRGY 3 or Duro-Guard ISO II-G Roof Board Roofing Adhesive, 6-inch o.c. Fleece CR-20 (splatter applied) or WB II Min. 22 ga., Type B, Min. 2-inch ACFoam II, Duro-Guard Min. 0.25-inch SECUROCK Hot asphalt or Board -Max, Duro-Fleece or Duro- Fleece Plus / Duro- S-14. Grade 33 steel or ISO II -A, H-Shield, Duro-Guard ISO ll- Note 2 1 per 1.33 ft2 Gypsum -Fiber Roof Board CR-20, Insta-Stik or Trufast Fleece CR-20 (splatter -60.0 structural concrete H, ENRGY 3 or Duro-Guard ISO II-G Roofing Adhesive, 6-inch o.c. applied) or WB II NEMO ETC, LLC Evaluation Report D9750.05.08-1110 for FL3559-R13 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 9 of 44 ONEMOletc. TABLE 2C: STEEL OR • .. .. RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED BONDED ROOF . INSULATION, System Top Insulation Layer MDP Deck (Note 1) Base Insulation Layer Roof Cover (Note 16) No Type Fasteners Attach (psf) DURO-LAST MEMBRANE APPLICATIONS: S-15. Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any Min. 0.25-inch Dens Deck or Dens Deck Prime Note 2 1 per 2.67 Duro-Last / SB I or WB II -30.0* steel or structural concrete combination ft2 Min. 22 a., Type B, Grade 33 g yp (Optional) One or more layers, any 1 per 2.67 Duro-Last, Duro-Last EV 5-16. steel or structural concrete combination Min. 0.25-inch Dens Deck Prime Note 2 ft2 or Duro-Tuff / 56 IV or -30.0* WB II S-17. Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any Min. Y22-inch Dens Deck or Dens Deck Prime Note 2 1 per 3.2 Duro-Last / SB I or WB II -30.0* steel or structural concrete combination ft2 Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any 1 per 3.2 Duro-Last, Duro-Last EV S-18. steel or structural concrete combination Min. %=-inch Dens Deck or Dens Deck Prime Note 2 ft2 or Duro-Tuff / SB IV or -30.0* yyg II S-19. Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any Min. 5/8-inch Dens Deck or Dens Deck Prime Note 2 1 per 4 ft2 Duro-Last / 513 1 or WB II -30.0* steel or structural concrete combination Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any Duro-Last, Duro-Last EV 5-20. steel or structural concrete combination Min. 5/8-inch Dens Deck or Dens Deck Prime Note 2 1 per 4 ft2 or Duro-Tuff / 5B IV or -30.0* WB 11 5-21. Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any Min. 1.0-inch ACFoam II, Duro-Guard 150 II -A Note 2 1 per 2 ft2 Duro-Last / WB II -37.S* steel or structural concrete combination or ACFoam Recover Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any Duro-Last, Duro-Last EV S 22. steel or structural concrete combination Min. 1.0-inch ACFoam 11, Duro-Guard ISO II -A Note 2 1 per 2 ft2 or Duro-Tuff / 5B IV or -37.5* WB II Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any Min. 0.25-inch SECUROCK Gypsum -Fiber Roof 1 per 2.67 Duro-Last, Duro-Last EV S 23 steel or structural concrete combination Board Note 2 ft2 or or Duro-Tuff / SB IV or -37.5* II S 24 Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any steel or structural concrete combination Min. 1.5-inch ACFoam 11, Duro-Guard 150 II -A Note 2 1 per 2 ft2 Duro-Last / WB 1 -45.0* S-25. Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any Min. 1.5-inch ACFoam 11, Duro-Guard ISO II -A Note 2 1 per 2 ft2 Duro-Last, Duro-Last EV -45.0* steel or structural concrete combination or Duro-Tuff / SB IV 5-26. Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any Min. 2-inch ACFoam II, Duro-Guard 150 II -A or Note 2 1 per 4 ft2 Duro-Last / SB 1 -45.0* steel or structural concrete combination ACFoam III, Duro-Guard ISO III -A Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any 5 27 steel or structural concrete combination Min. 2-inch ACFoam III, Duro-Guard 150 III -A Note 2 1 per 4 ft2 Duro-Last / WB 1 -45.0* S 28 Min. 22 ga., Type B, Grade 33 One or more layers, any Min. 0.25-inch Invinsa Roof Board Note 2 1 per 2 ft2 Duro-Last / SB IV 45.0* steel or structural concrete combination, min. 1.5-inch thick 5 29. Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any steel or structural concrete combination Min. 0.25-inch Dens Deck or Dens Deck Prime Note 2 1 per 2 ft2 Duro-Last / SB I or WB II 45.0* NEMO ETC, LLC Evaluation Report D9750.05.08-R10 for FL1559-R13 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 02019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 10 of 44 ONEMOletc. TABLE 2C: STEEL OR •.. .. RECOVER TYPE C-1: MECHANICALLY BONDEDSYSTEM ATTACHED INSULATION, ROOF COVER System Top Insulation Layer MDP Deck (Note 1) Base Insulation Layer Roof Cover (Note 16) Type Fasteners Attach No. (psf) Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any Duro-Last, Duro-Last EV 5-30. Min. 0.25-inch Dens Deck or Dens Deck Prime Note 2 1 per 2 ft z or Duro-Tuff / 5B IV or -45.0 steel or structural concrete combination WB II Min. 22 a., Type B, Grade 33 g yp (Optional) One or more layers, an ( p ) y y Min. 0.25-inch SECUROCK Gypsum -Fiber Roof yp Duro-Last, Duro-Last EV 5-31. steel or structural concrete combination Board Note 2 1 per 2 ft2 or Duro-Tuff / SB IV or -45.0* WB II Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any Min. 5/8-inch SECUROCK Gypsum -Fiber Roof Duro-Last, Duro-Last EV S-32. steel or structural concrete combination Board Note 2 1 per 4 ft2 or Duro-Tuff / 513 IV or -45.0* WB II 5-33. Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any Min. 2-inch ACFoam 11, Duro-Guard ISO II -A Dekfast #15 with Dekfast 1 per 2 ft2 Duro-Last / SB 1 -60.0 steel or structural concrete combination Hex Min. 22 ga., Type B, Grade 33 One or more layers, any Min. 0.25-inch SECUROCK Gypsum -Fiber Roof 1 per 1.33 Duro-Last, Duro-Last EV S-34. steel or structural concrete combination, min. 1.5-inch thick Board Note 2 ft2 or Duro-Tuff / SB IV or -67.5 WB II 5-35. Min. 22 ga., Type B, Grade 33 One or more layers, any Min. 0.25-inch Dens Deck Prime Note 2 (#15 Extra Heavy 1 per 1.67 Duro-Last, Duro-Last EV -67.5 steel or structural concrete combination, min. 1.5-inch thick Duty only) ftZ or Duro-Tuff / 5B IV 5-36. Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any Min. 0.25-inch Dens Deck Dekfast #15 with Dekfast 1 per 2 ft2 Duro-Last / SB I or WB 11 -75.0 steel or structural concrete combination Hex Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any Min. 15/32-inch APA Rated, Grade B-C OMG XHD with OMG 5-37. steel or structural concrete combination plywood Flat Bottom Plates (3- 1 per 2 ft' Duro-Last / SB I or WB II -90.0 inch square metal) Min. 22 ga., Type B, Grade 33 One or more layers, any Min. 0.5-inch SECUROCK Gypsum Fiber Roof Trufast #12 DP with Duro-Last, Duro-Last EV _ 5-38. steel combination, min. 1.5-inch total Board Trufast 3" Metal 1 per 1 ftZ or Duro-Tuff / SB IV or -97.5 thickness Insulation Plate WB 11 DURO-FLEECE OR DURO-FLEECE PLUS MEMBRANE APPLICATIONS: Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any 1 per 2.67 Duro-Fleece or Duro- S-39. steel or structural concrete combination Min. 0.25-inch Dens Deck Prime Note 2 W Fleece Plus / Duro-Fleece -30.0* CR-20 (splatter) or WB II Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any 1 per 3.2 Duro-Fleece or Duro- 5-40. steel or structural concrete combination Min. Y.-inch Dens Deck or Dens Deck Prime Note 2 ft2Fleece Plus / Duro-Fleece -30.0* CR-20 (splatter) or WB II Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any Duro-Fleece or Duro- S-41. Min. 5/8-inch Dens Deck or Dens Deck Prime Note 2 1 per 4 ftZ Fleece Plus / Duro-Fleece -30.0* steel or structural concrete combination CR-20 (splatter) or WB II Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any Min. 0.25-inch SECUROCK Gypsum -Fiber Roof 1 per 2.67 Duro-Fleece or Duro- 5-42. steel or structural concrete combination Board Note 2 ft2Fleece Plus / Duro-Fleece -37.5* CR-20 (splatter) or WB II NEMO ETC, LLC Certificate of Authorization #32455 ©2019 NEMO ETC, LLC 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Duro-Last Single Ply Roof Systems; (800) 248-0280 Evaluation Report D9750.05.08-R10 for FL1559-R13 Revision 10: 10/17/2019 Appendix 1, Page 11 of 44 OMEMO I etc. TABLE 2C: STEEL OR •.. .. RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF System Top Insulation Layer MDP Deck (Note i) Base Insulation Layer Roof Cover (Note 16) Type Fasteners Attach No. (Psf) 5-43. Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any Min. 1.0-inch ACFoam II, Duro-Guard ISO II -A Note 2 1 per 2 ft2 Duro-Fleece or Duro- -37.5* steel or structural concrete combination Fleece Plus / WB II Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A, 5-44. Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any ACFoam III, Duro-Guard ISO III -A, H-Shield, Note 2 1 per 2 ft2 Duro-Fleece or Duro- -45.0* steel or structural concrete combination Duro-Guard ISO II-H, ENRGY 3, Duro-Guard Fleece Plus / WB II ISO II-G or ISO 95+ GLISO 5-45. Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any Min. 0.25-inch SECUROCK Gypsum -Fiber Roof Note 2 1 per 2 ft2 Duro-Fleece or Duro- Fleece Plus / Duro-Fleece -45.0* steel or structural concrete combination Board CR-20 (splatter) or WB II Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any Min. 5/8-inch SECUROCK Gypsum -Fiber Roof Duro-Fleece or Duro- 5-46. Note 2 1 per 4 ft2 Fleece Plus /Duro-Fleece -45.0* steel or structural concrete combination Board CR-20 (splatter) or WB II 5-47. Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any Min. 0.5-inch Dens Deck Note 2 1 per 2 ft2 Duro-Fleece or Duro- q5.0* steel or structural concrete combination Fleece Plus / WB II Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A, Duro-Fleece or Duro- 5-48. steel or structural concrete combination ACFoam III or 150 95+ GL Note 2 1 per 2 ft2 Fleece Plus / Duro-Fleece -45.0 Adhesive Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any Duro-Fleece or Duro- 5-49. steel or structural concrete combination Min. 0.5-inch Dens Deck Note 2 1 per 2 ft2 Fleece Plus / Duro-Fleece -45.0 Adhesive Min. 22 ga., Type B, Grade 33 One or more layers, any Min. 0.25-inch SECUROCK Gypsum -Fiber Roof 1 per 1.33 Duro-Fleece or Duro- 5-50. steel or structural concrete combination, min. 1.5-inch thick Board Note 2 ft2 Fleece Plus / Duro-Fleece -67.5 CR-20 (splatter) or WB II Min. 22 ga., Type B, Grade 33 One or more layers, any Note 2 (#15 Extra Heavy 1 per 1.67 Duro-Fleece or Duro- 5-51. steel or structural concrete combination, min. 1.5-inch thick Min. 0.25-inch Dens Deck Prime Duty only) ft2 Fleece Plus / Duro-Fleece -67.5 CR-20 (splatter) 5-52. Min. 22 ga., Type B, Grade 33 (Optional) One or more layers, any Min. 0.25-inch Dens Deck Prime Note 2 1 per 1.33 Duro-Fleece or Duro- -67.5 steel or structural concrete combination, min. 1.5-inch thick ft2 Fleece Plus / WB II Min. 22 ga., Type B, Grade 33 One or more layers, any Min. 0.5-inch SECUROCK Gypsum Fiber Roof Trufast #12 DP with Duro-Fleece or Duro- 5-53. combination, min. 1.5-inch total Trufast 3" Metal 1 per 1 ft 2 Fleece Plus / Duro-Fleece -97.5 steel thickness Board Insulation Plate CR-20 (splatter) or WB II NEMO ETC, LLC Evaluation Report D9750.05.08-1310 for FL1559-R33 Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 12 of 44 ONEMOletc. TABLE 2D: STEEL DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER PLATE-BONDEDSYSTEM TYPE C-2: MECHANICALLY ATTACHED INSULATION, ROOF COVER System Deck Insulation Layer Attach MDP Roof Cover /Attach No. (Note 1) (Note 14) Fasteners Density (psf) RHINOBOND INDUCTION WELD: Min. 22 ga., type One or more layers, any Duro-Last #15 Extra Heavy Duty Drill Point Z 1 per 4 ft Duro-Last (min. 40-mil), Duro-Tuff (min. 50-mil) or Duro- S-54. 8, Grade 33 steel combination Fasteners with RHINOBOND Insulation Plate (2 x 2-ft grid) Last EV (min. 50-mil) induction welded to RHINOBOND -37.5 (PVC) Insulation Plate (PVC) using RHINOBOND Installation Tool Min. 22 ga., type One or more layers, any Duro-Last #15 Extra Heavy Duty Drill Point 1 per bz Duro-Last (min. 40-mil), Duro-Tuff (min. 50-mil) or Duro- 5-55. B, Grade 33 steel combination Fasteners with RHINOBOND Insulation Plate (24 x 36 inch grid d pattern) Last EV (min. 50-mil) induction welded to RHINOBOND -45.0' (PVC) Insulation Plate (PVC) using RHINOBOND Installation Tool Min. 22 ga., type One or more layers, any Duro-Last #15 Extra Heavy Duty Drill Point 1 per 2.29 ftz Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro- 5-56. B Grade 33 steel combination Fasteners with RHINOBOND Insulation Plate (14 parts per 4 x 8 ft board Tuff (min. 80-mil) induction welded to RHINOBOND -45.0 (PVC) in 18 x 18 inch grid pattern) Insulation Plate (PVC) using RHINOBOND Installation Tool One or more layers DURO- 1 per 4 ft' GUARD ISO II -A, DURO-GUARD (8 parts per 4 x 8 ft board) Min. 20 ga., Type ISO II-G, DURO-GUARD 150 II-H, OMG XHD with RHINOBOND Insulation Plate parts spaced 24" o.c. in rows spaced Duro-Last (min.40-mil), Duro-Tuff (min. 50-mil) or Duro- S-57. N, Grade 40 steel DURO-GUARD 150 III -A or (PVC) 24"o.c., while mointainingfastener engagement with the topflange of Last EV (min. 50-mil) induction welded to RHINOBOND -52.5 DURO-GUARD ISO III-H;top the Type N deck profile. Every -other Insulation Plate (PVC) using RHINOBOND Installation Tool layer min. 1-inch set of two (2) rows is staggered 8- inchesfrom the previous set. Min. 18 ga., type One or more layers, any Duro-Last #15 Extra Heavy Duty Drill Point 12-inch o.c. in rows spaced Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro- S-58. B Grade 33 steel combination, preliminarily Fasteners with RHINOBOND Insulation Plate 60-inch o.c. Tuff (min. 80-mil) induction welded to RHINOBOND -30.0 attached (Note 5) (PVC) Insulation Plate (PVC) using RHINOBOND Installation Tool Min. 18 ga., type One or more layers, any Duro-Last #15 Extra Heavy Duty Drill Point 6-inch o.c. in rows spaced Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro- S-59. B Grade 33 steel combination, preliminarily Fasteners with RHINOBOND Insulation Plate 120-inch o.c. Tuff (min. 80-mil) induction welded to RHINOBOND -45.0 attached (Note 5) (PVC) Insulation Plate (PVC) using RHINOBOND Installation Tool Min. 18 ga., type One or more layers, any Duro-Last #15 Extra Heavy Duty Drill Point 12-inch o.-in rows spaced Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro- 5-60. B, Grade 33 steel combination, preliminarily Fasteners with RHINOBOND Insulation Plate 48inch o.c. Tuff (min. 80-mil) induction welded to RHINOBOND -45.0 attached (Note 5) (PVC) Insulation Plate (PVC) using RHINOBOND Installation Tool Min. 18 ga., type One or more layers, any Duro-Last #15 Extra Heavy Duty Drill Point 6-inch o.c. in rows spaced Duro-Last (min. 40-mil), Duro-Tuff (min. 50-mil) or Duro- 5-61. B Grade 33 steel combination, preliminarily Fasteners with RHINOBOND Insulation Plate 72-inch o.c. Last EV (min. 50-mil) induction welded to RHINOBOND -52.5 attached (Note 5) (PVC) Insulation Plate (PVC) using RHINOBOND Installation Tool Min. 18 ga., type One or more layers, any Duro-Last #15 Extra Heavy Duty Drill Point 6-inch o.c. in rows spaced Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro- S-62. B Grade 33 steel combination, preliminarily Fasteners with RHINOBOND Insulation Plate 96-inch o.c. Tuff (min. 80-mil) induction welded to RHINOBOND -52.5 attached (Note 5) (PVC) Insulation Plate (PVC) using RHINOBOND Installation Tool Min. 18 ga., type One or more layers, any Duro-Last #15 Extra Heavy Duty Drill Point 6-inch o.c. in rows spaced Duro-Last (min. 40-mil), Duro-Tuff (min. 50-mil) or Duro- S-63. B Grade 33 steel combination, preliminarily Fasteners with RHINOBOND Insulation Plate 48-inch D.C.Last EV (min. 50-mil) induction welded to RHINOBOND -82.5 attached (Note 5) (PVC) Insulation Plate (PVC) using RHINOBOND Installation Tool Min. 18 ga., type One or more layers, any Duro-Last #15 Extra Heavy Duty Drill Point 6-inch o.c. in rows spaced Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro- S-64. B, Grade 33 steel combination, preliminarily Fasteners with RHINOBOND Insulation Plate 60-inch o.c. Tuff (min. 80-mil) induction welded to RHINOBOND -82.5 attached (Note 5) (PVC) Insulation Plate (PVC) using RHINOBOND Installation Tool NEMO ETC, LLC Certificate of Authorization #32455 ©2019 NEMO ETC, LLC 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Duro-Last Single Ply Roof Systems; (800) 248-0280 Evaluation Report D9750.05.08-R10 for FL3559-R13 Revision 10: 10/17/2019 Appendix 1, Page 13 of 44 ONEMOjetc. TABLE 21): STEEL DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER PLATE-BONDEDSYSTEM TYPE C-2: MECHANICALLY ATTACHED INSULATION, ROOF COVER System Deck Insulation Layer Attach MDP Roof Cover / Attach No. (Note 1) (Note 14) Fasteners Density (psf) One or more layers, any Min. 18 ga., type Duro-Last #15 Extra Heavy Duty Drill Point 6-inch o.c. in rows spaced Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro- S-65. combination, preliminarily B, Grade 33 steel Fasteners with RHINOBOND Insulation Plate 48-inch o.c. Tuff (min. 80-mil) induction welded to RHINOBOND -90.0 attached (Note 5) (PVC) Insulation Plate (PVC) using RHINOBOND Installation Tool MOWELD INDUCTION WELD: Min. 22 ga., type One or more layers, any SFS Intec Dekfast DF-#15-PH3 with isoweld® 6 ft' per fastener Duro-Last (min. 40 mil), Duro-Last EV (min. 50 mil) or Duro- S-66. B Grade 40 steel combination, min. 1.5-inch Fl-P-6.8-PVC Plates 2 x 3-ft grid, staggered Tuff (min. 50 mil) induction welded to SFS isoweld® Fl-P- -37.5 6.8-PVC Plates with SFS isoweld 3000 stand-up tool Min. 22 ga., type One or more layers, any SFS Intec Dekfast DF-#12-PH3 or DF-#15-PH3 6 ft' per fastener Duro-Last (min. 40 mil), Duro-Last EV (min. 50 mil) or Duro- S-67. B Grade 80 steel combination, min. 1.5-inch Fastener with isoweld® F1-P-6.8-PVC Plates 2 x 3-ft grid, staggered Tuff (min. 50 mil) induction welded to SFS isoweld® F1-P- -37.5 6.8-PVC Plates with SFS isoweld 3000 stand-up tool Min. 22 ga., type One or more layers, any SFS Intec Dekfast DF-#15-PH3 with isoweld® 4 ft' per fastener Duro-Last (min. 40 mil), Duro-Last EV (min. 50 mil) or Duro- 5-68. B Grade 40 steel combination, min. 1.5-inch Fl-P-6.8-PVC Plates 2 x 2-ft grid, staggered Tuff (min. 50 mil) induction welded to SFS isoweld® F1-P- -52.5 6.8-PVC Plates with SFS isoweld 3000 stand-up tool Min. 22 ga., type One or more layers, any SFS Intec Dekfast DF-#12-PH3 or DF-#15-PH3 4 ft' per fastener Duro-Last (min. 40 mil), Duro-Last EV (min. 50 mil) or Duro- 5-69. B Grade 80 steel combination, min. 1.5-inch Fastener with isoweld® Fl-P-6.8-PVC Plates 2 x 2-ft grid, staggered Tuff (min. 50 mil) induction welded to SFS isoweld° Fl-P- -52.5 6.8-PVC Plates with SF5 isoweld 3000 stand-up tool Min. 22 ga., type One or more layers, any SFS Intec Dekfast DF-#15-PH3 with isoweld° 3 ft' per fastener Duro-Last (min. 40 mill, Duro-Last EV (min. 50 mil) or Duro- 5-70. B Grade 40 steel combination, min. 1.5-inch Fl-P-6.8-PVC Plates 1.5 x 2-ft grid, staggered Tuff (min. 50 mil) induction welded to 5F5 isoweld® F1-P- -82.5 6.8-PVC Plates with SFS isoweld 3000 stand-up tool Min. 22 ga., type One or more layers, any SFS Intec Dekfast DF-#12-PH3 or DF-#15-PH3 3 ft2 per fastener Duro-Last (min. 40 mil), Duro-Last EV (min. 50 mil) or Duro- S-71. B Grade 80 steel combination, min. 1.5-inch Fastener with isoweld® Fl-P-6.8-PVC Plates 1.5 x 2-ft grid, staggered Tuff (min. 50 mil) induction welded to SFS isoweld° F1-P- -82.5 6.8-PVC Plates with SFS isoweld 3000 stand-up tool Min. 22 ga., type One or more layers, any SFS Intec Dekfast DF-#15-PH3 with isoweld° 12-inch o.c. in rows spaced Duro-Last (min. 40 mil), Duro-Last EV (min. 50 mil) or Duro- S 72. B, Grade 40 steel combination, min. 1.5-inch, Fl-P-6.8-PVC Plates 60-inch o.c. Tuff (min. 50 mil) induction welded to SFS isoweld® Fl-P- -45.0 preliminarily attached (Note 5) 6.8-PVC Plates with SFS isoweld® 3000 stand-up tool Min. 22 ga., type One or more layers, any SFS Inter Dekfast DF-#12l-P- DF-#15tes 12-inch o.-ic. in rows spaced Duro-Last (min. 40 mil), Duro-Last EV (min. 50 mil) or Duro- S-73. B, Grade 80 steel combination, min. 1.5-inch, .8 Fastener with isoweld®Fl-P-6.8-PVC Plates 50-inch o.c. Tuff (min. 50 mil) induction welded to SFS isoweld® Fl-P- -45.0 preliminarily attached (Note 5) 6.8-PVC Plates with SFS isoweld® 3000 stand-up tool Min. ga., type One or more layers, any SFS Dekfast DF-#15-PH3 with isoweld° 6-inch o.c. in rows spaced Duro-Last (min. 40 mil), Duro-Last EV (min. 50 mil) or Duro- 5-74. B, Grade 40 steel combination, min. 1.5-inch, - Fl-P6.8-6.8-PVC Plates 60-inch o.c. Tuff (min. 50 mil) induction welded to SFS isoweld® Fl-P- -90.0 preliminarily attached (Note 5) 6.8-PVC Plates with SFS isoweld® 3000 stand-up tool Min. ga., type One or more layers, any SFS Inter Dekfast DF-#12-PH3DF-#15-P-PVC 6-inch o.c. in rows spaced Duro-Last (min. 40 mil), Duro-Last EV (min. 50 mil) or Duro- 5-75. B, Grade 80 steel combination, min. 1.5-inch, Fastener with isoweld®F1-P 68.Plates s 60-inch o.c. Tuff (min. 50 mil) induction welded to SFS isoweld® Fl-P- -90.0 preliminarily attached (Note 5) 6.8-PVC Plates with SFS isoweld° 3000 stand-up tool TRUFAST INDUCTION WELD:. ' NEMO ETC, LLC Evaluation Report D9750.05.08-1110 for FL1559-1113 Certificate of Authorization #32455 61H EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 14 of 44 NNEMOjetc. TABLE 2D: STEEL DECKS - NEW CONSTRUCTION, .. OR RECOVER SYSTEM TYPE C-2: MECHANICALLY ATTACHED INSULATION, PLATE -BONDED ROOF COVER System Deck Insulation Layer Attach Roof Cover /Attach MDP No. (Note 1) (Note 14) Fasteners Density (psf) 1 per 5.33 ft' Duro-Last (min. 40 mil), Duro-Last EV (min. 50 mil) or Duro- S-76. Min. ga., type One or more layers, anye Trufast #15 EHD with Trufast PVC IW Plate (6 parts per 4x8 ft board on Tuff (min. 50 mil) induction welded to Trufast PVC IW Plates -45.0' B, Grade 33 steel combination, min. 2-inch a 24x36-inch pattern) with Trufast Induction Welding Too] and Magnets 1 per 4 ftZ Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction S 77 Min. 22 ga., type One or more layers, any Trufast #15 EHD with Trufast PVC IW Plate (8 parts per 4x8 ft board on welded to Trufast PVC IW Plates with Trufast Induction -52.5 B, Grade 33 steel combination, min. 2-inch a 24x24-inch pattern) Welding Tool and Magnets 1 per 4 ftZ Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro- S-78. Min. 22 ga., type One or more layers, any Trufast #15 EHD with Trufast PVC IW Plate (8 parts per 4x8 ft board on Tuff (min. 60 mil) induction welded to Trufast PVC IW Plates -60.0 B, Grade 33 steel combination, min. 2-inch a 2424-inch pattern) with Trufast Induction Welding Tool and Magnets Min. 22 ga., type One or more layers, any 1 per 3.2 ft' Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction S 79 B, Grade 33 steel combination, min. 2-inch Trufast #15 EHD with Trufast PVC IW Plate (10 parts per 4x8 ft board welded to Trufast PVC IW Plates with Trufast Induction -60.0 on a 24x20-inch pattern) Welding Tool and Magnets 1 per 3.2 ftZ Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro- 5-80. Min. 22 ga., type B, Grade 33 steel One or more layers, any combination, min. 2-inch Trufast #15 EHD with Trufast PVC IW Plate (10 parts per 4x8 ft board Tuff (min. 60 mil) induction welded to Trufast PVC IW Plates -67.5 on a 24x20-inch pattern) with Trufast Induction Welding Tool and Magnets 1 per 2.7 ftz Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction S-81. Min. 22 ga., type One or more layers, any Trufast #15 EHD with Trufast PVC IW Plate (12 parts per 4x8 ft board welded to Trufast PVC IW Plates with Trufast Induction -67.5 B, Grade 33 steel combination, min. 2-inch per FM LPDS 1-29) Welding Tool and Magnets 1 per 2.7 ftZ Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro- S 82 Min. 22 ga., type One or more layers, any Trufast #15 EHD with Trufast PVC IW Plate (12 parts per 4x8 ft board Tuff (min. 60 mil) induction welded to Trufast PVC IW Plates -82.5 B, Grade 33 steel combination, min. 2-inch per FM LPDS 1-29) with Trufast Induction Welding Tool and Magnets 1 per 2 ftz Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction 5-83. Min. 22 ga., type One or more layers, any Trufast #15 EHD with Trufast PVC IW Plate (16 parts per 4x8 ft board welded to Trufast PVC IW Plates with Trufast Induction -90.0 B, Grade 33 steel combination, min. 2-inch on a 12x24-inch pattern) Welding Tool and Magnets Min. Z2 ga., type One or more layers, any 1 per 2 ftZ Duro -Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro- 5-84. B, Grade 33 steel combination, min. 2-inch Trufast #15 EHD with Trufast PVC IW Plate (16 parts per 4x8 ft board Tuff (min. 60 mil) induction welded to Trufast PVC IW Plates -112.5 on a 12x24-inch pattern) with Trufast Induction Welding Tool and Magnets Min. 22 ga., type One or more layers, any 1 per 1.8 ftZ Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction 5-85. B, Grade 33 steel combination, min. 2-inch Trufast #15 EHD with Trufast PVC IW Plate (18 parts per 4x8 ft board welded to Trufast PVC IW Plates with Trufast Induction -105.0 on an 18x16-inch pattern) Welding Tool and Magnets Min. 22 ga., type One or more layers, any 1 per 1.8 ft' Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro- S-86. B, Grade 33 steel combination, min. 2-inch Trufast #15 EHD with Trufast PVC IW Plate (18 parts per 4x8 ft board Tuff (min. 60 mil) induction welded to Trufast PVC IW Plates -120.0 on an 18x16-inch pattern) with Trufast Induction Welding Tool and Magnets 1 per 1.3 ftZ Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction S 87 Min. 22 ga., type One or more layers, any Trufast #15 EHD with Trufast PVC IW Plate (24 parts per 4x8 ft board welded to Trufast PVC IW Plates with Trufast Induction -135.0 B, Grade 33 steel combination, min. 2-inch on a 12x16-inch pattern) Welding Tool and Magnets NEMO ETC, LLC Certificate of Authorization #32455 02019 NEMO ETC, LLC 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Duro-Last Single Ply Roof Systems; (800) 248-0280 Evaluation Report D9750.05.08-1110 for FL3559-R13 Revision 10: 10/17/2019 Appendix 1, Page 15 of 44 ONEMOletc. TABLE 2D: STEEL DECKS - NEW CONSTRUCTION, •.. .. RECOVER PLATE-BONDEDSYSTEM TYPE C-2: MECHANICALLY ATTACHED INSULATION, ROOF COVER System Deck Insulation Layer Attach MDP No. (Note 1) Roof Cover /Attach (Note 14) Fasteners Density (psf) Min. 22 ga., type One or more layers, any 1 per 1.3 ft' Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro- 5-88. B, Grade 33 steel combination, min. 2-inch Trufast #15 EHD with Trufast PVC IW Plate (24 parts per 4x8 ft board Tuff (min. 60 mil) induction welded to Trufast PVC IW Plates -172.5 on a 12x16-inch pattern) with Trufast Induction Welding Tool and Magnets Min. 22 ga., type One or more layers, any 1 per 1 ft' Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction 5 89 B, Grade 33 steel combination, min. 2-inch Trufast #15 EHD with Trufast PVC IW Plate (32 parts per 4x8 ft board welded to Trufast PVC IW Plates with Trufast Induction -142.5 per FM LPDS 1-29) Welding Tool and Magnets Min. 22 ga., type One or more layers, any 1 per 1 ft' Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro- S-90. B, Grade 33 steel combination, min. 2-inch Trufast #15 EHD with Trufast PVC IW Plate (32 parts per 4x8 ft board Tuff (min. 60 mil) induction welded to Trufast PVC IW Plates -217.5 per FM LPD51-29) with Trufast Induction Welding Tool and Magnets Min. 22 ga., type One or more layers, any 12-inch o.c. in rows spaced Duro-Last (min. 40 mil), Duro-Last EV (min. 50 mil) or Duro- 5-91. B, Grade 33 steel combination, min. 2-inch, Trufast #15 EHD with Trufast PVC IW Plate 60-inch o.c. Tuff (min. 50 mil) induction welded to Trufast PVC IW Plates -45.0 preliminarily attached with Trufast Induction Welding Tool and Magnets Min. 22 ga., type One or more layers, any 12-inch o.c. in rows spaced Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction S-92. B, Grade 33 steel combination, min. 2-inch, Trufast #15 EHD with Trufast PVC IW Plate 48-inch o.c. welded to Trufast PVC IW Plates with Trufast Induction -52.5 preliminarily attached Welding Tool and Magnets Min. 22 ga., type One or more layers, any 12-inch o.c. in rows spaced Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro- S-93. B, Grade 33 steel combination, min. 2-inch, Trufast #15 EHD with Trufast PVC IW Plate 48-inch o.c. Tuff (min. 60 mil) induction welded to Trufast PVC IW Plates -60.0 preliminarily attached with Trufast Induction Welding Tool and Magnets Min. 22 ga., type One or more layers, any 12-inch o.c. in rows spaced Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction 5-94. B Grade 33 steel combination, min. 2-inch Trufast #15 EHD with Trufast PVC IW Plate 36-inch o.c. welded to Trufast PVC IW Plates with Trufast Induction -60.0 Welding Tool and Magnets Min. 22 ga., type One or more layers, any 12-inch o.c. in rows spaced Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro- S-95. B Grade 33 steel combination, min. 2-inch Trufast #15 EHD with Trufast PVC IW Plate 36-inch o.c. Tuff (min. 60 mil) induction welded to Trufast PVC IW Plates -82.5 with Trufast Induction Welding Tool and Magnets Min. 22 a., type g YP One or more layers, any 6-inch o.c. in rows spaced Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction 5-96. B, Grade 33 steel combination, min. 2-inch, Trufast #15 EHD with Trufast PVC IW Plate 72-inch o.c. welded to Trufast PVC IW Plates with Trufast Induction -67.5 preliminarily attached Welding Tool and Magnets Min. ga., typee One or more layers, any 6-inch o.c. in rows spaced Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro- S 97 B, Grade 33 steel combination, min. 2-inch, Trufast #15 EHD with Trufast PVC IW Plate 72-inch o.c. Tuff (min. 60 mil) induction welded to Trufast PVC IW Plates -75.0 preliminarily attached with Trufast Induction Welding Tool and Magnets Min. 22 a., type g YP One or more layers, any 6-inch o.c. in rows spaced Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction 5-98. B, Grade 33 steel combination, min. 2-inch, Trufast #15 EHD with Trufast PVC IW Plate 60-inch o.c. welded to Trufast PVC IW Plates with Trufast Induction -75.0 preliminarily attached Welding Tool and Magnets Min. 22 ga., type One or more layers, any 6-inch o.c. in rows spaced Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro- S-99. B, Grade 33 steel combination, min. 2-inch, Trufast #15 EHD with Trufast PVC IW Plate 60-inch o.c. Tuff (min. 60 mil) induction welded to Trufast PVC IW Plates -90.0 preliminarily attached with Trufast Induction Welding Tool and Magnets NEMO ETC, LLC Evaluation Report D9750.05.08-R1D for FL3559-1113 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 16 of 44 ONEMOjetc. TABLE 21): STEEL DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER PLATE-BONDEDSYSTEM TYPE C-2: MECHANICALLY ATTACHED INSULATION, ROOF COVER System Deck Insulation Layer Attach Roof Cover /Attach MDP No. (Note 1) (Note 14) Fasteners Density (psf) Min. ga., type One or more layers, any 6-inch o.c. in rows spaced Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction 5-100. B, Grade 33 steel combination, min. 2-inch, Trufast #15 EHD with Trufast PVC IW Plate 48-inch o.c. welded to Trufast PVC IW Plates with Trufast Induction -90.0 preliminarily attached Welding Tool and Magnets Min. ga., type One or more layers, any 6-inch o.c. in rows spaced Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro- S-101. B, Grade 33 steel combination, min. 2-inch, Trufast #15 EHD with Trufast PVC IW Plate 48-inch o.c. Tuff (min. 60 mil) induction welded to Trufast PVC IW Plates -112.5 preliminarily attached with Trufast Induction Welding Tool and Magnets Min. 22 ga., type One or more layers, any 6-inch o.c. in rows spaced Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction 5-102. B Grade 33 steel combination, min. 2-inch Trufast #15 EHD with Trufast PVC IW Plate 36-inch o.c. welded to Trufast PVC IW Plates with Trufast Induction -112.5 Welding Tool and Magnets Min. 22 ga., type One or more layers, any 6-inch o.c. in rows spaced Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro- 5-103. B Grade 33 steel combination, min. 2-inch Trufast #15 EHD with Trufast PVC IW Plate 36-inch o.c. Tuff (min. 60 mil) induction welded to Trufast PVC IW Plates -150.0 with Trufast Induction Welding Tool and Magnets NEMO ETC, LLC Certificate of Authorization #32455 02019 NEMO ETC, LLC 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Duro-Last Single Ply Roof Systems; (800) 248-0280 Evaluation Report D9750.05.08-1110 for F1.3559-1113 Revision 10: 10/17/2019 Appendix 1, Page 17 of 44 ONEMOjetc. TABLE 2E: STEEL DECKS - NEW CONSTRUCTION, .. OR RECOVER SYSTEM TYPE D-1: PRELIMINARILY ATTACHED INSULATION, MECHANICALLY ATTACHED ROOF COVER Insulation (Note 14) Roof Cover System Deck (Note 1) Attach MDP No. Type Membrane Fasteners F Attach (psf) (Note 5) STANDARD LAP SYSTEMS: _ Min. 22 ga., Type B, 50 One or more layers, any Prelim. Duro-Last EV, Duro-Last #15 Extra Heavy Duty Standard Lao System fastened 18-inch o.c. within 6-inch wide 5-104. ksi steel combination, min. 1-inch attach min. 50-mil Drill Point Fastener with Duro- laps spaced 54-inch o.c. Laps sealed with 1.5-inch heat weld. -30.0 Last Poly -Plate Min. 22 ga., Type B, 50 One or more layers, any Prelim. Duro-Last EV, Duro-Last #15 Extra Heavy Duty Standard Lao System fastened 12-inch o.c. within 6-inch wide 5-105. ksi steel combination, min. 1-inch attach min. 50-mil Drill Point Fastener with Duro- laps spaced 54-inch o.c. Laps sealed with 1.5-inch heat weld. 37.5 Last Cleat Plate Min. 22 ga., Type B, One or more layers, any Prelim. Duro-Last, Duro-Last #15 Extra Heavy Duty Standard Lao System fastened iZ-inch o.c. within 5.75-inch wide 5-106. Grade 33 steel combination, min. 1.5-inch attach min. 40 mil Drill Point Fastener with Duro- tabs spaced 120-inch o.c. -37.5 Last Cleat Plate Min. 18 ga., Type B, One or more layers, any Prelim. Duro-Last, Duro-Last #15 Extra Heavy DutyStandard Lao System fastened 9-inch o.c. within 3-inch wide 5-107. Grade 33 steel combination, min. 1.5-inch attach min. 40 mil Drill Point Fastener with Duro- tabs spaced 60-inch o.c. -45.0 Last Poly -Plate Min. 22 ga., Type B, 50 One or more layers, any Prelim. Duro-Last EV, Duro-Last #15 Extra Heavy Duty Standard Lao System fastened 12-inch o.c. within 6-inch wide 5-108. ksi steel combination, min. 1-inch attach min. 50-mil Drill Point Fastener with Duro- laps spaced 54-inch o.c. Laps sealed with 1.5-inch heat weld. -45.0 Last Poly -Plate Min. 22 ga., Type B, One or more layers, any Prelim. Duro-Last EV, Duro-Last #15 Extra Heavy Duty Standard Lao System fastened 6-inch o.c. within 6-inch wide 5-109. Grade 40 steel combination, min. 1-inch attach min. 50-mil Drill Point Fastener with Duro laps spaced 114-inch o.c. Laps sealed with 1.5-inch heat weld. 45.0 Last Poly -Plate Min. 22 ga., Type B, One or more layers, any Prelim. Duro-Tuff, Duro-Last #15 Extra Heavy Duty Standard Lap System fastened 12-inch o.c. within 4-inch wide 5-110. Grade 33 steel combination, min. 1.5-inch total attach min. 50 mil Drill Point Fasteners with Duro- laps spaced 116-inch o.c. Laps sealed with 1.5-inch heat weld. -45.0 thickness, min. 16-psi top layer Last Cleat Plates Duro-Last #15 Extra Heavy Duty 5-111. Min. 22 ga., type B, One or more layers, any Prelim. Duro-Last, Drill Point Fasteners with Duro- Standard Lap Svstem fastened 6-inch o.c. within 3-inch wide Grade 80 steel combination, min. 1.5-inch attach min. 40 mil Last 2.4-inch Barbed Metal tabs spaced 84-inch o.c. -60.0 Plates 5-112. Min. 22 ga., Type B, 50 One or more layers, any Prelim. Duro-LaEV, Duro-Last #15 Extra Heavy Dutyst Standard Lap System fastened 6-inch o.c. within 6-inch wide ksi steel combination, min. 1-inch attach min. 50-mil Drill Point Fastener with Duro- laps spaced 54-inch o.c. Laps sealed with 1.5-inch heat weld. -75.0 Last Cleat Plate DURO-RDOFLAP SYSTEMS: Min. 22 ga., Type B, One or more layers, any Prelim. Duro-Last, Duro-Last #15 Extra Heavy Duty Duro-Roof Lap Svstem fastened 12-inch o.c. within 5.75-inch 5-113. Grade 33 steel combination, min. 1.5-inch attach min. 40 mil Drill Point Fastener with Duro- wide tabs spaced 120-inch o.c. Tab Sealer 4725 at max. 60 -45.0 Last Cleat Plate ft2/gal. 5-114. Min. 22 ga., type B, One or more layers, any Prelim. Duro-Last, Duro-Last #15 Extra Heavy Duty Duro-Roof Lap System fastened 12-inch o.c. within 6-inch wide Grade 80 steel combination, min. 1.5-inch attach min. 40 mil Drill Point Fasteners with Duro- tabs spaced 57-inch o.c. Tab Sealer 4725 at max. 60 ft2/gal. -52.5 Last 3-inch Metal Plates NEMO ETC, LLC Evaluation Report 09750.05.08-1110 for F1.1559-1133 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 18 of 44 ONEMOjetc. TABLE 2E: STEEL DECKS - NEW CONSTRUCTION, R.. .. RECOVER ATTACHEDSYSTEMTYPED-1: PRELIMINARILY INSULATION, MECHANICALLY ATTACHED ROOF Insulation (Note 14) Roof Cover System Deck (Note 1) Attach MDP No. Type Membrane Fasteners Attach (psf) (Note 5) Min. 22 ga., type B, One or more layers, any Prelim. Duro-Last, Duro-Last #15 Extra Heavy Duty Duro-Roof Lao System fastened 12-inch o.c. within 5.75-inch S-115. Grade 80 steel combination, min. 1.5-inch attach min. 40 mil Drill Point Fastener with Duro- wide tabs spaced 84-inch o.c. Tab Sealer 4725 at max. 60 -52.5 Last Cleat Plate ft2/gal. Min. 22 ga., type B, One or more layers, any Prelim. Duro-Last, Duro-Last #15 Extra Heavy Duty Duro-Roof Lao System fastened 12-inch o.c. within 5.75-inch S-116. Grade 80 steel combination, min. 1.5-inch attach min. 40 mil Drill Point Fastener with Duro- wide tabs spaced 57-inch o.c. Tab Sealer 4725 at max. 60 -67.5 Last Cleat Plate ft2/gal. Min. 22 ga., type B, One or more layers, any Prelim. Duro-Last, Duro-Last #15 Extra Heavy Duty Duro-RoofLao System fastened 6-inch o.c. within 3-inch wide 5-117. Grade 80 steel combination, min. 1.5-inch attach min. 40 mil Drill Point Fastener with Duro- tabs spaced 60-inch o.c. Tab Sealer 4725 at max. 60 ft2/gal. -67.5 Last Batten Bar Min. 22 ga., type B, One or more layers, any Prelim. Duro-Last, Duro-Last #15 Extra Heavy Duty Duro-Roof Lao System fastened 6-inch o.c. within 6-inch wide S-11S. Grade 80 steel combination, min. 1.5-inch attach min. 40 mil Drill Point Fasteners with Duro- tabs spaced 120-inch o.c. Tab Sealer 4725 at max. 60 ft2/gal. 82 5 Last 3-inch Metal Plates Min. 22 ga., type B. One or more layers, any Prelim. Duro-Last, Duro-Last #15 Extra Heavy Duty Duro-Roof Lap System fastened 6-inch o.c. within 5.75-inch 5-119. Grade 80 steel combination, min. 1.5-inch attach min. 40 mil Drill Point Fastener with Duro- wide tabs spaced 120-inch o.c. Tab Sealer 4725 at max. 60 -82.5 Last Cleat Plate ft2/gal. Min. 22 ga., type B, One or more layers, any Prelim. Duro-Last, Duro-Last #15 Extra Heavy Duty Duro-Roof Lao System fastened 6-inch o.c. within 5.75-inch 5-120. Grade 80 steel combination, min. 1.5-inch attach min. 40 mil Drill Point Fastener with Duro- wide tabs spaced 84-inch o.c. Tab Sealer 4725 at max. 60 -97.5 Last Cleat Plate ft2/gal. Min. 22 ga., type B, One or more layersany ,any , Prelim. -L Duro-Last, Duro-Last #15 Extra Heavy Duty Duro-Roof Lap System fastened 6-inch o.c. within 5.75-inch 5-121. Grade SO steel combination, min. attach min. mil Drill Point Fastener with Duro- wide tabs spaced 57-inch o.c. Tab Sealer 4725 at max. 60 -135.0 Last Cleat Plate ft2/ga1. Min. 22 ga., type B, One or more layers, any Prelim. Duro-Last, Duro-Last #15 Extra Heavy Duty Duro-Roof Lap System fastened 6-inch o.c. within 6-inch wide 5-122. Grade 80 steel combination, min. 1.5-inch attach min. 40 mil t Fasteners Drill Point Fasteners with OMG Drill P tabs spaced 25-inch o.c. Tab Sealer 4725 at max. 60 ft2/gal. -142.5 E hook Plates NEMO ETC, LLC Certificate of Authorization #32455 ©2019 NEMO ETC, LLC 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Duro-Last Single Ply Roof Systems; (800) 248-0290 Evaluation Report D9750.05.08-1110 for FL3559-1113 Revision 10: 10/17/2019 Appendix 1, Page 19 of 44 ONEMOIetc. TABLE 2F: STEEL DECKS - NEW CONSTRUCTION REROOF (TEAR -OFF) TYPE VAPORSYSTEM D-2: THERMAL BARRIER WITH BARRIER PRELIMINARILY ATTACHED INSULATION, MECHANICALLY ATTACHED ROOF COVER System Deck Thermal Vapor Insulation Roof Cover MDP No. (Note 1) Barrier Barrier Base Top Attach Slip Sheet Membrane Fasteners Attach (psf) (Optional) One or more (Optional if Min. 0.25- layers DURO-GUARD ISO using base Duro-Last #14 Min. 22 ga., inch Dens Duro-Last II -A, DURO-GUARD ISO II- layer(s) Heavy Duty with Duro-Last Duro-Last #15 Extra Standard Lao Type B, Deck Prime, Vapor G, DURO-GUARD ISO II-H, insulation) Min. 3-inch Metal Geotextile Duro-Last, Heavy Duty Drill Point System fastened 5-123. Grade 40 loose -laid, Barrier, self- DURO-GUARD ISO III -A or 0.5-inch DURO- Plates; 1 per slip sheet, min. 40 mil Fastener with Duro- 12-inch o.c. within -52.5 steel adhered or adhering DURO-GUARD ISO III-H, GUARD EPS 5.3 ftz; 6 parts loose -laid Last Poly -Plate or 3-inch wide tabs mech. DURO-GUARD EPS Type Type II-C or Duro-Last Cleat Plate spaced 60-inch o.c.. attached II-C or DURO-GUARD EPS DURO-GUARD per 48 ft FGF loose -laid EPS FGF board (Optional) One or more (Optional if Min. 0.25- layers DURO-GUARD ISO using base Duro-Last #14 Standard Lao inch Dens II -A, DURO-GUARD 150 II- layer(s) Heavy Duty Duro-Last #15 Extra System fastened Min. 22 ga., Deck Prime, Duro-Last G, DURO-GUARD ISO II-H, insulation) Min. with Duro-Last Geotextile Heavy Duty Drill Point 12-inch o.c. within S-124. Type B, Grade 40 loose -laid, Vapor Barrier, DURO-GUARD ISO III -A or 0.5-inch DURO- 3-inch Metal slip sheet, Duro-Tuff, Fastener with Duro- 6-inch wide laps -52.5 steel adhered or self- adhering DURO-GUARD ISO III-H, GUARD EPS Plates; 1 per 5.3 6 loose -laid min. 50 mil Last Poly -Plate or spaced 54-inch o.c. Side laps mech. DURO-GUARD EPS Type Type II-C or partsx8 Duro-Last Cleat Plate sealed attached II-C or DURO-GUARD EPS DURO-GUARD per 4a; per ft with 1.5-inch heat- FGF loose -laid EPS FGF board weld NEMO ETC, LLC Evaluation Report D9750.05.08-1110 for FL1559-R13 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 20 of 44 ONEMO I etc. TABLE 3A: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER REFER To NOTE 17 .. O.BARRIER OPTIONS System Deck Base Insulation Layer Top Insulation Layer MDP No. (Note 1) Type Attach (Notes 6 & 7) Roof Cover (Note 16) (psf) Type Attach (Notes 6 & 7) DURO-LAST MEMBRANE APPLICATIONS: Min. 2,500 psi (Optional) Min. 1.5-inch ACFoam II, Duro- C-1. structural concrete Guard 150 II -A Ashland Pliodeck Min. 0.25-inch Dens Deck Ashland Pliodeck Duro-Last / WB 1 -37.5 C 2 Min. 2,500 psi Min. 1.5-inch ACFoam 11, Duro-Guard ISO II -A Ashland Pliodeck (Optional) Additional layers of base Ashland Pliodeck Duro-Last / SB I or WB II -45.0 structural concrete insulation C 3 Min. 2,500 psi Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A Ashland Pliodeck (Optional) Additional layers of base Ashland Pliodeck Duro-Last, Duro-Last EV or -45.0 structural concrete insulation Duro-Tuff/5B IV or WB II C 4 Min. 2,500 psi Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A Ashland Pliodeck (Optional) Additional layers of base Ashland Pliodeck Duro-Last / WB 1 -82.5 structural concrete insulation C-5. Min. 2,500 psi Min. 2-inch 150 95+ GL Ashland Pliodeck Min. 0.25-inch SECUROCK Gypsum- Ashland Pliodeck Duro-Last / WB II -217.5 structural concrete Fiber Roof Board C-6. Min. 2,500 psi Min. 2-inch 150 95+ GL Ashland Pliodeck Min. 0.25-inch SECUROCK Gypsum- Ashland Pliodeck Duro-Last, Duro-Last EV or -217.5 structural concrete Fiber Roof Board Duro-Tuff / SB IV or WB 11 Min. 1.5-inch ACFoam II, Duro-Guard 150 II -A, C 7. Min. 2,500 psi H-Shield, Duro-Guard ISO II-H, ENRGY 3 or Board -Max Min. 0.25-inch SECUROCK Gypsum- Board -Max Duro-Last, Duro-Last EV or -247.5 structural concrete Duro-Guard 150 II-G Fiber Roof Board Duro-Tuff / 513 IV or WB 11 C 8 Min. 2,500 psi Min. 0.75-inch Duro-Guard EPS Type IX Board -Max Min. 0.25-inch SECUROCK Gypsum- Board -Max Duro-Last, Duro-Last EV or -247.5 structural concrete Fiber Roof Board Duro-Tuff/ 513 IV or WB 11 C 9 Min. 2,500 psi Min. 0.75-inch Duro-Guard EPS Type IX Board -Max Min. 0.25-inch SECUROCK Gypsum- Board -Max Duro-Last, Duro-Last EV or -255.0 structural concrete Fiber Roof Board Duro-Tuff / SB IV or WB II Min. 1.5-inch ACFoam 11, Duro-Guard ISO II -A, C-10. Min. 2,500 psi H-Shield, Duro-Guard 150 II-H, ENRGY 3 or CR-20 Min. 0.25-inch SECUROCK Gypsum- CR-20 Duro-Last, Duro-Last EV or -247.5 structural concrete Duro-Guard 150 II-G Fiber Roof Board Duro-Tuff / SB IV or WB 11 C-11. Min. 2,500 psi Min. 0.75-inch Duro-Guard EPS Type 11, VIII or CR-20 Min. 0.25-inch SECUROCK Gypsum- CR-20 Duro-Last, Duro-Last EV or structural concrete IX Fiber Roof Board Duro-Tuff / SB IV or WB II -247.5 C-12. Min. 2,500 psi Min. 0.75-inch Duro-Guard EPS Type 11, VIII or CR-20 Min. 0.25-inch SECUROCK Gypsum- Duro-Last, Duro-Last EV or structural concrete IX Fiber Roof Board CR-20 Duro-Tuff / 5B IV or WB 11 255.0 Min. 2,500 psi (Optional) Min. 1.5-inch ACFoam 11, Duro- C-13. structural concrete Guard 150 II -A Insta-Stik Min. 0.25-inch Dens Deck Insta-Stik Duro-Last / WB I 37.5 C-14. Min. 2,500 psi Min. 1.5-inch ACFoam 11, Duro-Guard ISO II -A Insta-Stik (Optional) Additional layers of base Insta-Stik Duro-Last / SB I or WB II -45.0 structural concrete insulation C-15. Min. 2,500 psi Min. 1.5-inch ACFoam 11, Duro-Guard 150 II -A Insta-Stik (Optional) Additional layers of base Insta-Stik Duro-Last, Duro-Last EV or -45.0 structural concrete insulation Duro-Tuff / SB IV or WB II C-16. Min. 2,500 psi Min. 1.5-inch ACFoam 11, Duro-Guard ISO II -A Insta-Stik (Optional) Additional layers of base Insta-Stik Duro-Last / WB 1 -82.5 structural concrete insulation NEMO ETC, LLC Certificate of Authorization #32455 ©2019 NEMO ETC, LLC 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Duro-Last Single Ply Roof Systems; (800) 248-0280 Evaluation Report D9750.05.08-R10 for FL3559-R33 Revision 10: 10/17/2019 Appendix 1, Page 21 of 44 ONEMOletc. TABLE 3A: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER REFER To NOTE 17 FOR VAPOR BARRIER OPTIONS System Deck Base Insulation Layer Top Insulation Layer MDP No. (Note 1) Roof Cover (Note 16) (psf) Type Attach (Notes 6 & 7) Type Attach (Notes 6 & 7) Min. 2,500 si p Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A, Min. 0.25-inch SECUROCK Gypsum Duro-Last, Duro-Last EV or C-17. structural concrete H-Shield, Duro-Guard ISO II-H, ENRGY 3 or Insta-Stik Fiber Roof Board Insta-Stik Duro-Tuff / SB IV or WB II -247.5 Duro-Guard ISO II-G C-18. Min. psi Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A Hot asphalt (Optional) Additional layers of base Hot asphalt Duro-Last / SB I or WB II -45.0 structuralUral concrete insulation C 19 Min. 2,500 psi Min. 1.5-inch ACFoam 11, Duro-Guard ISO II -A Hot asphalt (Optional) Additional layers of base Hot asphalt Duro-Last, Duro-Last EV or -45.0 structural concrete insulation Duro-Tuff / SB IV or WB II C-20. Min. 2,500 psi Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A Hot asphalt (Optional) Additional layers of base Hot asphalt Duro-Last / WB I -75.0 structural concrete insulation Min. 2,500 psi Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A, Min. 0.25-inch SECUROCK Gypsum- Duro-Last, Duro-Last EV or C-21. structural concrete H-Shield, Duro-Guard 150 II-H, ENRGY 3 or Hot asphalt Fiber Roof Board Hot asphalt Duro-Tuff / SB IV or WB II 247.5 Duro-Guard ISO II-G C 22 Min. 2,500 psi (Optional) Min. 1.5-inch ACFoam II, Duro- OlyBond 500 Min. 0.25-inch Dens Deck OlyBond 500 Duro-Last / WB 1 -37.5 structural concrete Guard ISO II -A C-23. Min. 2,500 psi Min. 1.5-inch ACFoam II, Duro-Guard ISO 11-A OlyBond 500 (Optional) Additional layers of base OlyBond 500 Duro-Last / SB I or WB II -45.0 structural concrete insulation C 24 Min. 2,500 psi Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A OlyBond 500 (Optional) Additional layers of base OlyBond 500 Duro-Last, Duro-Last EV or -45.0 structural concrete insulation Duro-Tuff /58IV or WB 11 C-25. Min. 2,500 psi Min. 1.5-inch ACFoam 11, Duro-Guard ISO II -A OlyBond 500 (Optional) Additional layers of base OlyBond 500 Duro-Last / WB 1 -82.5 structural concrete insulation Min. 2,500 si P Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A, Min. 0.25-inch SECUROCK Gypsum- Duro-Last, Duro-Last EV or C-26. structural concrete H-Shield, Duro-Guard ISO II-H, ENRGY 3 or OlyBond 500 Fiber Roof Board OlyBond 500 Duro-Tuff / SB IV or WB II -247.5 Duro-Guard ISO II-G C 27. Min. 2,500 psi Min. 1.5-inch ACFoam 11, Duro-Guard ISO II -A, OlyBond Classic, full Min. 0.25-inch SECUROCK Gypsum- OlyBond Classic, full Duro-Last, Duro-Last EV or structural concrete H-Shield, Duro-Guard ISO II-H coverage Fiber Roof Board coverage Duro-Tuff / SB IV or WB II 457.5 C 28 Min. 2,500 psi (Optional) Min. 1.5-inch ACFoam 11, Duro- Trufast Roofing Min. 0.25-inch Dens Deck Trufast Roofing Duro-Last / WB 1 -37.5 structural concrete Guard ISO II -A Adhesive Adhesive C 29 Min. 2,500 psi Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A Trufast Roofing (Optional) Additional layers of base Trufast Roofing Duro-Last / SB 1 or WB II -45.0 structural concrete Adhesive insulation Adhesive C-30. Min. 2,500 psi Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A Trufast Roofing (Optional) Additional layers of base Trufast Roofing Duro-Last / WB 1 -82.5 structural concrete Adhesive insulation Adhesive DURO-FLEECE OR DURO-..FLEECE PLUS MEMBRANE APPLICATIONS: _ C-31. Min. 2,500 psi Min. 1.5-inch ACFoam 11, Duro-Guard 150 II -A Ashland Pliodeck (Optional) Additional layers of base Ashland Pliodeck Duro-Fleece or Duro-Fleece -45.0 structural concrete insulation Plus / WB II rC3. Min. 2,500 psi Min. 2-inch ISO 95+ GL Ashland Pliodeck Min. 0.25-inch SECUROCK Gypsum- Ashland Pliodeck Duro-Fleece or Duro-Fleece -217.5 structural concrete Fiber Roof Board Plus / WB II NEMO ETC, LLC Evaluation Report D9750.05.08-R10 for FL3559-1113 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 22 of 44 ONEMOjetc. TABLE3A: STRUCTURAL CONCRETE DECKS -NEW CONSTRUCTION .. REROOF SYSTEM TYPE A-1: BONDED BONDED ROOF COVER REFER . ..VAPOR OPTIONS System Deck Base Insulation Layer Top Insulation Layer MDP Roof Cover (Note 16) Type Attach (Notes 6 & 7) Type Attach (Notes 6 & 7) No. (Note 1) (psf) Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A, Duro-Fleece or Duro-Fleece C-33. Min. 2,500 psi H-Shield, Duro-Guard ISO II-H, ENRGY 3 or Board -Max Min. 0.25-inch SECUROCK Gypsum- Board -Max Plus / Duro-Fleece CR-20 -247.5 structural concrete Duro-Guard ISO II-G Fiber Roof Board (splatter) or WB II Duro-Fleece or Duro-Fleece C-34. Min. 2,500 psi Min. 0.75-inch Duro-Guard EPS Type IX Board -Max Min. 0.25-inch SECUROCK Gypsum- Board -Max Plus / Duro-Fleece CR-20 -247.5 structural concrete Fiber Roof Board (splatter) or WB II Min. 2,500 psi Min. 0.25-inch SECUROCK Gypsum- Duro-Fleece or Duro-Fleece C-35. Min. 0.75-inch Duro-Guard EPS Type IX Board -Max Board -Max Plus / Duro-Fleece CR-20 -255.0 structural concrete Fiber Roof Board (splatter) or WB II Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A, Duro-Fleece or Duro-Fleece C-36. Min. 2,500 psi H-Shield, Duro-Guard ISO II-H, ENRGY 3 or CR-20 Min. 0.25-inch SECUROCK Gypsum- CR-20 Plus / Duro-Fleece CR-20 -247.5 structural concrete Duro-Guard ISO II-G Fiber Roof Board (splatter) or WB II Duro-Fleece or Duro-Fleece C-37. Min. 2,500 psi Min. 0.75-inch Duro-Guard EPS Type II, VIII or CR-20 Min. 0.25-inch SECUROCK Gypsum- CR-20 Plus / Duro-Fleece CR-20 -247.5 structural concrete IX Fiber Roof Board (splatter) or WB II Min. 2,500 psi Min. 0.75-inch Duro-Guard EPS Type II, VIII or Min. 0.25-inch SECUROCK Gypsum- Duro-Fleece or Duro-Fleece C-38. CR-20 CR-20 Plus / Duro-Fleece CR-20 -255.0 structural concrete IX Fiber Roof Board (splatter) or WB II C-39. Min. 2,500 psi Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A Insta-Stik (Optional) Additional layers of base Insta-Stik Duro-Fleece or Duro-Fleece -45.0 structural concrete insulation Plus / WB II Min. 2,500 psi Min. 1.5-inch ACFoam 11, Duro-Guard ISO II -A, Min. 0.25-inch SECUROCK Gypsum- Duro-Fleece or Duro-Fleece C-40. H-Shield, Duro-Guard ISO II-H, ENRGY 3 or Insta-Stik Insta-Stik Plus / Duro-Fleece CR-20 -247.5 structural concrete Duro-Guard ISO II-G Fiber Roof Board (splatter) or WB II C-41. Min. 2,500 psi Min. 1.5-inch ACFoam 11, Duro-Guard ISO II -A Hot asphalt (Optional) Additional layers of base Hot asphalt Duro-Fleece or Duro-Fleece -45.0 structural concrete insulation Plus / WB II Min. 1.5-inch ACFoam II, Duro-Guard I5O II -A, Duro-Fleece or Duro-Fleece C-42. Min. 2,500 psi H-Shield, Duro-Guard ISO II-H, ENRGY 3 or Hot asphalt Min. 0.25-inch SECUROCK Gypsum - Hot asphalt Plus / Duro-Fleece CR-20 -247.5 structural concrete Duro-Guard 150 II-G Fiber Roof Board (splatter) or WB II C-43. Min. 2,500 psi Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A OlyBond 500 (Optional) Additional layers of base OlyBond 500 Duro-Fleece or Duro-Fleece -45.0 structural concrete insulation Plus / WB II Min. 2,500 psi Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A, Min. 0.25-inch SECUROCK Gypsum- Duro-Fleece or Duro-Fleece C-44. structural concrete H-Shield, Duro-Guard ISO II-H, ENRGY 3 or OlyBond 500 Fiber Roof Board OlyBond 500 Plus / Duro-Fleece CR-20 -247.5 Duro-Guard ISO 11-G (splatter) or WB II Min. 2,500 psi Min. 1.5-inch ACFoam 11, Duro-Guard ISO II -A, OlyBond Classic, full Min. 0.25-inch SECUROCK Gypsum- OlyBond Classic, full Duro-Fleece or Duro-Fleece C 45. structural concrete H-Shield, Duro-Guard ISO II-H coverage Fiber Roof Board coverage Plus / Duro-Fleece CR-20 457.5 (splatter) or WB II NEMO ETC, LLC Certificate of Authorization #32455 ©2019 NEMO ETC, LLC CH EDITION (2017) FBC NON-HVHZ EVALUATION Duro-Last Single Ply Roof Systems; (800) 248-0280 Evaluation Report D9750.05.08-R10 for FL3559-1113 Revision 10: 10/17/2019 Appendix 1, Page 23 of 44 ONEMOletc. TABLE 3A: STRUCTURAL CONCRETE DECKS - NEW ... REROOF SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER REFER To NOTE 17 FOR VAPOR BARRIER OPTIONS System Deck Base Insulation Layer Top Insulation Layer MDP No. (Note 1) Roof Cover (Note 16) (psf) Type Attach (Notes 6 & 7) Type Attach (Notes 6 & 7) Min. 2,500 psi Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A, Trufast Roofing Min. 0.5-inch Duro-Guard ISO HD -A or Trufast Roofing Duro-Fleece or Duro-Fleece C-46. structural concrete ENRGY 3 CGF, Duro-Guard ISO III-G, H-Shield Adhesive Duro-Guard 150 HD-H Adhesive Plus /Trufast Roofing -165.0 CG, Duro-Guard ISO III-H Adhesive, ribbons 4" o.c. Min. 0.25-inch Dens Deck, Dens Deck Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A, Prime, DEXcell FA Glass Mat Roof Duro-Fleece or Duro-Fleece C-47. Min. 2,500 psi 3 CGF, Duro-Guard ISO III-G, H-Shield Trufast Roofing Board, SECUROCK Gypsum -Fiber Roof Trufast Roofing Plus /Trufast Roofing 195.0 structural concrete CG, CG, CDu ro-Guard ISO III-H Adhesive Board or SECUROCK Glass -Mat Roof Adhesive Adhesive, ribbons 4" o.c. Board or min. 7/16" DEXcell Cement Roof Board Min. 2,500 psi Min. 1.5-inch ACFoam II, Duro-Guard I5O II -A, Trufast Roofing (Optional) Additional layers of base Trufast Roofing Duro-Fleece or Duro-Fleece C-48. structural concrete ENRGY 3 CGF, Duro-Guard ISO III-G, H-Shield Adhesive insulation Adhesive Plus / Trufast Roofing -345.0 CG, Duro-Guard ISO III-H Adhesive, ribbons 4" o.c. NEMO ETC, LLC Evaluation Report D9750.05.08-1110 for F13559-R13 Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 02019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 24 of 44 ONEMOletc. TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, •.. OR RECOVER PLATE-BONDEDSYSTEM TYPE C-2: MECHANICALLY ATTACHED INSULATION, ROOF COVER System Deck Insulation Layer Attach Roof Cover / Attach MDP No. (Note 1) (Note 14) Fasteners Density (Psf) RHINOBOND INDUCTION WELD: Min. 2,500 psi One or more layers, any Duro-Last #14 HD with RHINOBOND 1 per 2.67 ft' Duro-Last (min. 40-mil), Duro-Tuff (min. 50-mil) or Duro-Last EV C-49. structural concrete combination Insulation Plate (PVC) (12 parts per 4 x 8 ft board) (min. 50-mil) induction welded to RHINOBOND Insulation Plate -52.5 (PVC) using RHINOBOND Installation Tool Min. 2,500 psi One or more layers, any Duro-Last #14 HD with RHINOBOND 12-inch o.c. in rows spaced Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro-Tuff C-50. structural concrete combination, preliminarily Insulation Plate (PVC) 60-inch o.c. (min. 80-mil) induction welded to RHINOBOND Insulation Plate -37.5 attached (Note 5) (PVC) using RHINOBOND Installation Tool Min. 2,500 psi One or more layers, any Duro-Last #14 HD with RHINOBOND 12-inch o.c. in rows spaced Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro-Tuff C-51. structural concrete combination, preliminarily Insulation Plate (PVC) 48-inch o.c. (min. 80-mil) induction welded to RHINOBOND Insulation Plate -37.5 attached (Note 5) (PVC) using RHINOBOND Installation Tool Min. psi One or more layers, any Duro-Last HD with RHINOBOND 6-inch o.c. in rows spaced Duro-Last (min. 40-mil), Duro-Tuff (min. 50-mil) or Duro-Last EV C-52. structural concrete structural U combination, preliminarily Insulation Plate late (PVC) 60 inch o.c. (min. 50-mil) induction welded to RHINOBOND Insulation Plate -45.0 attached (Note 5) (PVC) using RHINOBOND Installation Tool Min. psi One or more layers, any Duro-Last HD with RHINOBOND 6-inch o.c. in rows spaced Duro-Last (min. 40-mil), Duro-Tuff (min. 50-mil) or Duro-Last EV C-53. U structural structural concrete combination, preliminarily late (PVC) Insulation Plate 48-inch o.c. (min. 50-mil) induction welded to RHINOBOND Insulation Plate -52.5 attached (Note 5) (PVC) using RHINOBOND Installation Tool ISOWELD INDUCTION WELD: Min. 2,500 psi One or more layers, , any ,any SFS Intec Dekfast DF-#14-PH3 or DF- 6 ft' per fastener Duro-Last (min. 40 mil), Duro-Last EV (min. 50 mil) or Duro-Tuff C-54. structural concrete combination, min. #15-PH3 with isoweld® F1-P-6.8-PVC 2 x grid, staggered (min. 50 mil) induction welded to SFS isoweld° F1-P-6.8-PVC -37.5 Plates Plates with SFS isoweld 3000 stand-up tool Min. 2,500 psi ' One or more layers, any SFS Intec Dekfast DF-#14-PH3 or DF- 4 ft' per fastener Duro-Last (min. 40 mil), Duro-Last EV (min. 50 mil) or Duro-Tuff C-55. structural concrete combination, min. 1.5-inch #15-PH3 with isoweld® F1-P-6.8-PVC 2 x 2-ft grid, staggered (min. 50 mil) induction welded to SFS isoweld® F1-P-6.8-PVC -52.5 Plates Plates with SFS isoweld 3000 stand-up tool Min. 2,500 psi One or more layers, any SFS Intec Dekfast DF-#14-PH3 or DF- 3 ft' per fastener Duro-Last (min. 40 mil), Duro-Last EV (min. 50 mil) or Duro-Tuff C-56. #15-PH3 with isoweld° F1-P-6.8-PVC (min. 50 mil) induction to SFS isoweld° F1-P-6.8-PVC -82.5 structural concrete combination, min. 1.5-inch Plates 1.5 x 2-ft grid, staggered welded Plates with SFS isoweld 3000 stand-up tool Min. 2,500 psi One or more layers, any SFS Intec Dekfast DF-#14-PH3 or DF 12-inch o.c. in rows spaced Duro-Last (min. 40 mil), Duro-Last EV (min. 50 mil) or Duro-Tuff C-57. structural concrete combination, min. 1.5-inch, #15-PH3 with isoweld® F1-P-6.8-PVC 60-inch o.c. (min. 50 mil) induction welded to SFS isoweld F1-P-6.8-PVC -45.0 preliminarily attached (Note 5) Plates Plates with SFS isoweld® 3000 stand-up tool Min. 2,500 psi One or more layers, any SFS Intec Dekfast DF-#14-PH3 or DF 6-inch o.c. in rows spaced Duro-Last (min. 40 mil) induction welded to SFS isoweldo Fl-P- C-58. structural concrete combination, min. 1.5-inch, #15-PH3 with isoweldm Fl-P-6.8-PVC 60-inch o.c. 6.8-PVC Plates with SFS isoweld® 3000 stand-up tool -90.0 preliminarily attached (Note 5) Plates TRUFAST INDUCTION WELD: Min. 2,500 psi One or more layers, any Trufast #14 HD or Trufast Fluted 1 per 5.33 ft' Duro-Last (min. 40 mil), Duro-Last EV (min. 50 mil) or Duro-Tuff C-59. structural concrete combination, min. 2-inch Concrete Nail with Trufast PVC IW (6 parts per 48 ft board on (min. 50 mil) induction welded to Trufast PVC IW Plates with -45.0 Plate a 2436-inch pattern) Trufast Induction Welding Tool and Magnets NEMO ETC, LLC Certificate of Authorization #32455 ©2019 NEMO ETC, LLC 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Duro-Last Single Ply Roof Systems; (800) 248-0280 Evaluation Report D9750.05.08-R10 for FL3559-R13 Revision 10: 10/17/2019 Appendix 1, Page 25 of 44 ONEMOjetc- F TABLE 313i STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, • .. .. RECOVER PLATE-BONDEDSYSTEM TYPE C-2: MECHANICALLY ATTACHED INSULATION, ROOF System Deck Insulation Layer Attach MDP No. (Note 1) (Note 14) Fasteners Density Roof Cover /Attach (psf) Min. 2,500 psi One or more layers, any Trufast #14 HD or Trufast Fluted 1 per 4 ft2 Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction C-60. structural concrete combination, min. 2-inch Concrete Nail with Trufast PVC IW (8 parts per 48 ft board on welded to Trufast PVC IW Plates with Trufast Induction Welding -52.5 Plate a 2424-inch pattern) Tool and Magnets Min. 2,500 psi One or more layers, any Trufast #14 HD or Trufast Fluted 1 per 4 ft' Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro-Tuff C-61. structural concrete combination, min. 2-inch Concrete Nail with Trufast PVC IW (8 parts per 4x8 ft board on (min. 60 mil) induction welded to Trufast PVC IW Plates with -60.0 Plate a 2424-inch pattern) Trufast Induction Welding Tool and Magnets Min. 2,500 psi One or more layers, any Trufast #14 HD or Trufast Fluted 1 per 3.2 ft' Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction C-62. structural concrete combination, min. 2-inch Concrete Nail with Trufast PVC IW (10 parts per 48 ft board welded to Trufast PVC IW Plates with Trufast Induction Welding -60.0 Plate on a 2420-inch pattern) Tool and Magnets Min. 2,500 psi One or more layers, any Trufast #14 HD or Trufast Fluted 1 per 3.2 ft2 Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro-Tuff C-63. structural concrete combination, min. 2-inch Concrete Nail with Trufast PVC IW (10 parts per 4x8 ft board (min. 60 mil) induction welded to Trufast PVC IW Plates with -67.5 Plate on a 24x20-inch pattern) Trufast Induction Welding Tool and Magnets Min. 2,500 psi One or more layers, any Trufast #14 HD or Trufast Fluted 1 per 2.7 ft2 Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction C-64. structural concrete combination, min. 2-inch Concrete Nail with Trufast PVC IW (12 parts per 48 ft board welded to Trufast PVC IW Plates with Trufast Induction Welding -67.5 Plate per FM LPDS 1-29) Tool and Magnets Min. 2,500 psi One or more layers, any Trufast #14 HD or Trufast Fluted 1 per 2.7 ft' Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro-Tuff C-65. structural concrete combination, min. 2-inch Concrete Nail with Trufast PVC IW (12 parts per 48 ft board (min. 60 mil) induction welded to Trufast PVC IW Plates with -82.5 Plate per FM LPDS 1-29) Trufast Induction Welding Tool and Magnets Min. 2,500 psi One or more layers, any Trufast #14 HD or Trufast Fluted 1 per 2 ft2 Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction C-66. structural concrete combination, min. 2-inch Concrete Nail with Trufast PVC IW (16 parts per 4x8 ft board welded to Trufast PVC IW Plates with Trufast Induction Welding -90.0 Plate on a 12x24-inch pattern) Tool and Magnets Min. 2,500 psi One or more layers, any Trufast #14 HD or Trufast Fluted 1 per 2 ft2 Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro-Tuff C-67. structural concrete combination, min. 2-inch Concrete Nail with Trufast PVC IW (16 parts per 48 ft board (min. 60 mil) induction welded to Trufast PVC IW Plates with -112.5 Plate on a 12x24-inch pattern) Trufast Induction Welding Tool and Magnets Min. 2,500 psi One or more layers, any Trufast #14 HD or Trufast Fluted 1 per 1.8 ft2 Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction C-68. Concrete Nail with Trufast PVC IW (18 parts per 4x8 ft board welded to Trufast PVC IW Plates with Trufast Induction Welding -105.0 structural concrete combination, min. 2-inch Plate on an 18x16-inch pattern) Tool and Magnets Min. 2,500 psi One or more layers, any Trufast #14 HD or Trufast Fluted 1 per 1.8 ft2 Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro-Tuff C-69. structural concrete combination, min. 2-inch Concrete Nail with Trufast PVC IW (18 parts per 4x8 ft board (min. 60 mil) induction welded to Trufast PVC IW Plates with -120.0 Plate on an 18x15-inch pattern) Trufast Induction Welding Tool and Magnets Min. 2,500 psi One or more layers, any Trufast #14 HD or Trufast Fluted 1 per 1.3 ft2 Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction C-70. Concrete Nail with Trufast PVC IW (24 parts per 4x8 ft board welded to Trufast PVC IW Plates with Trufast Induction Welding -135.0 structural concrete combination, min. 2-inch Plate on a 12x16-inch pattern) Tool and Magnets Min. 2,500 psi One or more layers, any Trufast #14 HD or Trufast Fluted 1 per 1.3 ft2 Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro-Tuff C-71. Concrete Nail with Trufast PVC IW (24 parts per 4x8 ft board (min. 60 mil) induction welded to Trufast PVC IW Plates with -172.5 structural concrete combination, min. 2-inch Plate on a 12x16-inch pattern) Trufast Induction Welding Tool and Magnets NEMO ETC, LLC - Evaluation Report D9750.05.08-1110 for FL3559-1133 Certificate of Authorization #32455 6- EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 26 of 44 NEMO ETC, LLC - Evaluation Report D9750.05.08-1110 for FL3559-1133 Certificate of Authorization #32455 6- EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 26 of 44 ONEMOletc. TABLE 313: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, .. OR RECOVER PLATE-BONDEDSYSTEM TYPE C-2: MECHANICALLY ATTACHED INSULATION, ROOF COVER System Deck Insulation Layer Attach Roof Cover /Attach MDP Fasteners Density No. (Note 1) (Note 14) (psf) Trufast #14 HD or Trufast Fluted 1 per 1 ftz Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction C 72. Min. 2,500 psi One or more layers, any Concrete Nail with Trufast PVC IW (32 parts per 4x8 ft board welded to Trufast PVC IW Plates with Trufast Induction Welding -142.5 structural concrete combination, min. 2-inch Plate per FM LPDS 1-29) Tool and Magnets Trufast #14 HD or Trufast Fluted 1 per 1 ft' Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro-Tuff C-73. Min. 2,500 psi One or more layers, any Concrete Nail with Trufast PVC IW (32 parts per 4x8 ft board (min. 60 mil) induction welded to Trufast PVC IW Plates with -217.5 structural concrete combination, min. 2-inch Plate per FM LPDS 1-29) Trufast Induction Welding Tool and Magnets Min. psi One or more layers, any Trufast #14 HD or Trufast Fluted 12-inch o. in rows spaced Duro-Last (min. 40 mil), Duro-Last EV (min. 50 mil) or Duro-Tuff C 74 u structural ral concrete combination, min. 2-inch, Concrete Nail with Trufast PVC IW - 60-inch o.c. (min. 50 mil) induction welded to Trufast PVC IW Plates with -45.0 preliminarily attached Plate Trufast Induction Welding Tool and Magnets Min. 2,500 psi One or more layers, any Trufast #14 HD or Trufast Fluted 12-inch o.c. in rows spaced Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction C-75. structural concrete combination, min. 2-inch, Concrete Nail with Trufast PVC IW 48-inch o.c. welded to Trufast PVC IW Plates with Trufast Induction Welding -52.5 preliminarily attached Plate Tool and Magnets Min. 2,500 psi One or more layers, any Trufast #14 HD or Trufast Fluted 12-inch o.c. in rows spaced Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro-Tuff C-76. structural concrete combination, min. 2-inch, Concrete Nail with Trufast PVC IW 48-inch o.c. (min. 60 mil) induction welded to Trufast PVC IW Plates with -60.0 preliminarily attached Plate Trufast Induction Welding Tool and Magnets Min. psi One or more layers, any Trufast #14 HD or Trufast Fluted 12-inch o.-in rows spaced Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction C 77 U structural ral concrete combination, min. 2-inch Concrete Nail with Trufast PVC IW 36inch o.c. welded to Trufast PVC IW Plates with Trufast Induction Welding -60.0 Plate Tool and Magnets Min. psi One or more layers, any Trufast #14 HD or Trufast Fluted 12-inch o.-in rows spaced Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro-Tuff C 78 structural ral concrete u combination, min. 2-inch Concrete Nail with Trufast PVC IW 36inch o.c. (min. 60 mil) induction welded to Trufast PVC IW Plates with 82.5 Plate Trufast Induction Welding Tool and Magnets Min. 2,500 psi One or more layers, any Trufast #14 HD or Trufast Fluted 6-inch o.c. in rows spaced Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction C-79. structural concrete combination, min. 2-inch, Concrete Nail with Trufast PVC IW 72-inch o.c. welded to Trufast PVC IW Plates with Trufast Induction Welding -67.5 preliminarily attached Plate Tool and Magnets Min. 2,500 psi One or more layers, any Trufast #14 HD or Trufast Fluted 6-inch o.c. in rows spaced Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro-Tuff C-80. structural concrete combination, min. 2-inch, Concrete Nail with Trufast PVC IW 72-inch o.c. (min. 60 mil) induction welded to Trufast PVC IW Plates with -75.0 preliminarily attached Plate Trufast Induction Welding Tool and Magnets Min. 2,500 psi One or more layers, any Trufast #14 HD or Trufast Fluted 6-inch o.c. in rows spaced Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction C-81. structural concrete combination, min. 2-inch, Concrete Nail with Trufast PVC IW 60-inch o.c. welded to Trufast PVC IW Plates with Trufast Induction Welding -75.0 preliminarily attached Plate Tool and Magnets Min. psi One or more layers, any Trufast #14 HD or Trufast Fluted 6-inch oin rows spaced Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro-Tuff C 82 u structural ral concrete combination, min. 2-inch, Concrete Nail with Trufast PVC IW 600-- inch o.c. (min. 60 mil) induction welded to Trufast PVC IW Plates with -90.0 preliminarily attached Plate Trufast Induction Welding Tool and Magnets Min. 2,500 psi One or more layers, any Trufast #14 HD or Trufast Fluted 6-inch o.c. in rows spaced Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction C 83. structural concrete combination, min. 2-inch, Concrete Nail with Trufast PVC IW 48-inch o.c. welded to Trufast PVC IW Plates with Trufast Induction Welding -90.0 preliminarily attached Plate Tool and Magnets NEMO ETC, LLC Evaluation Report D9750.05.08-R10 for FL3559-1113 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 02019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 27 of 44 ONEMOjetc. TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, • .. .. RECOVER PLATE-BONDEDSYSTEM TYPE C-2: MECHANICALLY ATTACHED INSULATION, ROOF COVER System Deck Insulation Layer Attach MDP No. (Note 1) (Note 14) Roof Cover / Attach Fasteners Density (psf) Min. 2,500 psi One or more layers, any Trufast #14 HD or Trufast Fluted 6-inch o.c. in rows spaced Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro-Tuff C-84, structural concrete combination, min. 2-inch, Concrete Nail with Trufast PVC IW 48-inch o.c. (min. 60 mil) induction welded to Trufast PVC IW Plates with -112.5 preliminarily attached Plate Trufast Induction Welding Tool and Magnets Min. 2,500 psi One or more layers, any Trufast #14 HD or Trufast Fluted 6-inch o.c. in rows spaced Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) induction C-85. structural concrete combination, min. 2-inch Concrete Nail with Trufast PVC IW 36-inch o.c. welded to Trufast PVC IW Plates with Trufast Induction Welding -112.5 Plate Tool and Magnets Min. 2,500 psi One or more layers , any Trufast #14 HD or Trufast Fluted 6-inch o.. in rows spaced c Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) or Duro-Tuff C-86. structural concrete combination, min. 2-inch Concrete Nail with Trufast PVC IW 36-inch o.c. (min. 60 mil) induction welded to Trufast PVC IW Plates with -150.0 Plate Trufast Induction Welding Tool and Magnets 3C: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER INSULATION,TABLE _SYSTEM TYPE D-1: PRELIMINARILY ATTACHED ROOF COVER Insulation (Note 14) Roof Cover System Deck MDP Attach No. (Note 1) Type Membrane Fasteners Attach (psf) (Note 5) STANDARD LAP SYSTEMS:- C 87 Min. 2,500 psi (Optional) One or more Prelim. Duro-Last, min. 40 Duro-Last #14 HD Fasteners with Standard Lap System fastened 9-inch o.c. within 3-inch wide structural concrete layers, any combination attached mil Duro-Last Cleat Plates tabs spaced 60-inch o.c. 37.5 Min. 2,500 psi (Optional) One or more Prelim. Duro-Last, min. 40 Duro-Last Concrete Screws #14 orDuro-Last Standard Lap System fastened 6-inch o.c. within 3-inch wide C 88 structural concrete layers, any combination attached mil Concrete Nails with Duro- tabs spaced 84-inch o.c. -60.0 Last 2.4-inch Barbed Metal Plates DURO-ROOF LAP SYSTEMS: ' C 89 Min. 2,500 psi (Optional) One or more Prelim. Duro-Last, min. 60 Duro-Last #14 HD Fasteners with Duro-Roof Lap System fastened 6-inch o.c. within 6-inch wide structural concrete layers, any combination attached mil Duro-Last Cleat Plates tabs spaced 120-inch o.c. Tab Sealer 4725 at max. 60 ft2/gal. -37.5 C-90. Min. 2,500 psi (Optional) One or more Prelim. Duro-Last, min. 40 Duro-Last Concrete Screws #14 or Duro-Roof Lao System fastened 12-inch o.c. within 6-inch wide structural concrete layers, any combination attached mil Duro-Last Concrete Nails with Duro- tabs spaced 57-inch o.c. Tab Sealer 4725 at max. 60 ft2/gal. -52.5 Last 3-inch Metal Plates C-91. Min. 2,500 psi (Optional) One or more Prelim. Duro-Last, min. 40 Duro-Last Concrete Screws #14 or Duro-Roof Lao System fastened 6-inch o.c. within 3-inch wide structural concrete layers, any combination attached mil Duro-Last Concrete Nails with Duro- tabs spaced 60-inch o.c. Tab Sealer 4725 at max. 60 ft2/gal. -67.5 Last Batten Bar C-92• Min. 2,500 psi (Optional) One or more Prelim. Duro-Last, min. 40 Duro-Last Concrete Screws #14 or Duro-Roof Lao System fastened 6-inch o.c. within 6-inch wide structural concrete layers, any combination attached mil, Duro-Last Concrete Nails with Duro- tabs spaced 120-inch o.c. Tab Sealer 4725 at max. 60 ft2/gal. -82.5 Last 3-inch Metal Plates C-93. Min. 2,500 psi (Optional) One or more Prelim. Duro-Last, min. 40 Duro-Last Concrete Screws #14 or Duro-Roof Lao System fastened 6-inch o.c. within 6-inch wide structural concrete layers, any combination attached mil Duro-Last Concrete Nails with OMG 2- tabs spaced 25-inch o.c. Tab Sealer 4725 at max. 60 ft2/gal. -142.5 3/8" Eyehook Plates NEMO ETC, LLC Evaluation Report D9750.05.08-R10 for FL3559-R33 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 28 of 44 ONEMID I etc. System No. Deck (Note 1) Primer TABLE 3D: STRUCTURAL CONCRETE DECKS - SYSTEM TYPE F: Vapor Barrier NEW CONSTRUCTION OR REROOF (TEAR -OFF) .BONDED ROOF Roof Cover (Note 16) MDP (psf) C-94. Structural concrete None Duro-Last Vapor Barrier, self -adhering Duro-Fleece or Duro-Fleece Plus / Duro-Fleece CR-20 (splatter applied) -502.5 C-95. Structural concrete ASTM D41 Duro-Last Torch Down Vapor Barrier, torch -applied Duro-Fleece or Duro-Fleece Plus / Duro-Fleece CR-20 (splatter applied) -502.5 C-96. Structural concrete None None Duro-Fleece or Duro-Fleece Plus / Duro-Fleece WB II Adhesive -673.0 C-97. Structural concrete None None Duro-Fleece or Duro-Fleece Plus / Duro-Fleece CR-20 (splatter applied) -1,025.0 NEMO ETC, LLC Certificate of Authorization #32455 ©2019 NEMO ETC, LLC 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Duro-Last Single Ply Roof Systems; (800) 248-0280 Evaluation Report D9750.05.08-1110 for FL1559-R13 Revision 10: 10/17/2019 Appendix 1, Page 29 of 44 ONE-MOletc. TABLE 4A: LIGHTWEIGHT CONCRETE OVER STEEL DECKS - NEW CONSTRUCTION . • REROOF SYSTEM TYPE A: BONDED INSULATION, BONDED ROOF COVER Base Insulation Layer Coverboard System Deck (Note 1) LWC (Note 15) Attach Roof Cover MDP Attach No. Type Type Ps (Notes 6 & 7) (Notes 6 & 7) PRE-EXISTENT CELLULAR LWC: BAREBACK MEMBRANE APPLICATIONS: Min. 22 ga., type Min. 200 psi, min. 2-inch thick cellular (Optional) Min. 1.5-inch ACFoam Ashland Min. 0.25-inch Dens Ashland LWC-1. BV steel lightweight insulating concrete 11, Duro-Guard ISO II -A Pliodeck Deck Pliodeck Duro-Last / WB I 37.5 Min. 22 ga., type Min. 200 psi, min. 2-inch thick cellular Min. 1.5-inch ACFoam II, Duro- Ashland (Optional) Additional Ashland LWC-2. BV steel lightweight insulating concrete Guard ISO II -A Pliodeck layers of base insulation Pliodeck Duro-Last / SB I or WB II 45.0 Min. 22 ga., type Min. 200 psi, min. 2-inch thick cellular Min. 1.5-inch ACFoam II, Duro- Ashland (Optional) Additional Ashland Duro-Last, Duro-Last EV or LWC-3. BV steel lightweight, insulating concrete Guard ISO II -A Pliodeck layers of base insulation Pliodeck Duro-Tuff/SB IV or WB II 45.0 Min. 22 ga., type Min. 200 psi, min. 2-inch thick cellular (Optional) Min. 1.5-inch ACFoam Min. 0.25-inch Dens LWC-4. BV steel lightweight insulating concrete II, Duro-Guard ISO II -A CR-20 Deck CR-20 Duro-Last / WB 1 -37.5 Min. 22 ga., type Min. 200 psi, min. 2-inch thick cellular Min. 1.5-inch ACFoam 11, Duro- (Optional) Additional LWC-5. BV steel lightweight insulating concrete Guard 150 II -A CR-20 layers of base insulation CR-20 Duro-Last / SB I Or WB II 45.0 Min. 22 ga., type Min. 200 psi, min. 2-inch thick cellular Min. 1.5-inch ACFoam II, Duro- (Optional) Additional Duro-Last, Duro-Last EV or LWC-6. BV steel I lightweight insulating concrete Guard ISO II -A CR-20 Ilayers of base insulation CR-20 I Duro-Tuff / SB IV or WB II -45.0 DURO-FLEECE AND DURO-FLEECE PLUS MEMBRANE APPLICATIONS: _ Min. 22 ga., type Min. 200 psi, min. 2-inch thick cellular Min. 1.5-inch ACFoam II, Duro- Ashland (Optional) Additional Ashland Duro-Fleece or Duro- LWC-7. BV steel lightweight insulating concrete Guard ISO II -A Pliodeck layers of base insulation Pliodeck Fleece Plus / WB II 45.0 Min. 22 ga., type Min. 200 psi, min. 2-inch thick cellular Min. 1.5-inch ACFoam II, Duro- (Optional) Additional Duro-Fleece or Duro- LWC-8. BV steel lightweight insulating concrete Guard ISO II -A CR-20 layers of base insulation CR-20 Fleece Plus / WB II -45.0 TABLE 413: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE A: BONDED INSULATION, BONDED ROOF COVER Base Insulation Layer Coverboard System No. Deck (Note 1) LWC (Note 15) Attach Attach Roof Cover MDP (psf) Type Type (Notes 6 & 7) (Notes 6 & 7) PRE-EXISTENTCELLULAR LWC: BAREBACK MEMBRANE APPLICATIONS:. Structural Min. 200 psi, min. 2-inch thick (Optional) Min. 1.5-inch ACFoam II, Duro- Ashland Ashland LWC-9. cellular lightweight insulating Min. 0.25-inch Dens Deck Duro-Last / WB 1 -37.5 concrete Guard ISO II -A Pliodeck Pliodeck concrete Structural Min. 200 psi, min. 2-inch thick Ashland (Optional) Additional Ashland LWC-30. cellular lightweight insulating Min. 1.5-inch ACFoam 11, Duro-Guard 150 II -A Duro-Last / SB I or WB II -45.0 concrete Pliodeck layers of base insulation Pliodeck concrete NEMO ETC, LLC Evaluation Report D9750.05.08-R10 for FL1559-1113 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 30 of 44 ONEMOletc.. TABLE 4B: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS - NEW .. CONSTRUCTION REROOF (TEAR -OFF) SYSTEM TYPE A: BONDED INSULATION, BONDED ROOF COVER Base Insulation Layer Coverboard System Deck LWC (Note 15) Roof Cover MDP Attach Attach No. (Note 1) Type Type (psf) (Notes 6 & 7) (Notes 6 & 7) Structural Min. 200 psi, min. 2-inch thick Ashland (Optional) Additional Ashland Duro-Last, Duro-Last EV or LWC-11. cellular lightweight insulating Min. 1.5-inch ACFoam 11, Duro-Guard ISO II -A -45.0 concrete Pliodeck layers of base insulation Pliodeck Duro-Tuff / 513 IV or WB II concrete Structural Min. 200 psi, min. 2-inch thick (Optional) Min. 1.5-inch ACFoam II, Duro- LWC-12. concrete cellular lightweight insulating Guard ISO II -A CR-20 Min. 0.25-inch Dens Deck CR-20 Duro-Last / WB 1 -37.5 concrete Min. 200 psi, min. 2-inch thick LWC-13. Structural cellular lightweight insulating Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A CR-20 (Optional) Additional CR-20 Duro-Last / SB I or WB II -45.0 concrete layers of base insulation concrete Structural Min. 200 psi, min. 2-inch thick (Optional) Additional Duro-Last, Duro-Last EV or LWC-14. cellular lightweight insulating Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A CR-20 CR 20 -45.0 concrete layers of base insulation Duro-Tuff / SB IV or WB 11 concrete DURO-FLEECE AND DURo-FLEECE PLUS MEMBRANE APPLICATIONS: - - Structural Min. 200 psi, min. 2-inch thick Ashland (Optional) Additional Ashland Duro-Fleece or Duro- LWC-15. cellular lightweight insulating Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A -45.0 concrete Pliodeck layers of base insulation Pliodeck Fleece Plus / WB II concrete Structural Min. 200 psi, min. 2-inch thick (Optional) Additional Duro-Fleece or Duro- LWC-16. cellular lightweight insulating Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A CR-20 CR-20 Fleece Plus / Duro-Fleece -45.0 concrete layers of base insulation concrete CR-20 (splatter) or WB II CELCORE(FL2037): BAREBACK MEMBRANE APPLICATIONS: LWC-17. Structural Min. 200 psi, min. 2-inch thick Min. 1.5-inch ACFoam II,'Duro-Guard ISO 11-A CR-20 (Optional) Additional CR-20 Duro-Last / WB 1 -82.5 concrete Celcore Cellular Concrete layers of base insulation Structural Min. 200 psi, min. 2-inch thick Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A, Min. 0.25-inch Duro-Last, Duro-Last EV or LWC-18. concrete Celcore Cellular Concrete H-Shield, Duro-Guard ISO 11-H, ENRGY 3 or CR-20 SECUROCK Gypsum -Fiber CR-20 Duro-Tuff / SB IV or WB II 222.5 Duro-Guard ISO II-G Roof Board .DURo-FLEECE AND DURo-FLEECE PLUS MEMBRANE APPLICATIONS: ' Structural Min. 200 psi, min. 2-inch thick Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A, Min. 0.25-inch Duro-Fleece or Duro- LWC-19. concrete Celcore Cellular Concrete H-Shield, Duro-Guard ISO II-H, ENRGY 3 or CR-20 SECUROCK Gypsum -Fiber CR-20 Fleece Plus / Duro-Fleece -222.5 Duro-Guard ISO II-G Roof Board CR-20 (splatter) or WB II ELASTIZELL (FL4994): BAREBACK MEMBRANE APPLICATIONS: Structural Min. 200 psi, min. 2-inch thick Ashland (Optional) Additional Ashland LWC-20. concrete ElRstizell. Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A Pliodeck layers of base insulation Pliodeck Duro-Last/ WB I 82.5 NEMO ETC, LLC Certificate of Authorization #32455 9)2019 NEMO ETC, LLC 6- EDITION (2017) FBC NON-HVHZ EVALUATION Duro-Last Single Ply Roof Systems; (800) 248-0280 Evaluation Report D9750.05.08-R10 for FL1559-R13 Revision 10: 10/17/2019 Appendix 1, Page 31 of 44 ONEMOjetc. TABLE 413: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION REROOF (TEAR -OFF) SYSTEM TYPE A: BONDED INSULATION, BONDED ROOF COVER Base Insulation Layer 'overboard System Deck MDP Type Attach Type Attach No. (Note 1) LWC (Note 15) Roof Cover (psf) (Notes 6 & 7) (Notes 6 & 7) Structural Min. 200 psi, min. 2-inch thick Ashland Min. 0.25-inch Ashland Duro-Last, Duro-Last EV or LWC-21. concrete Elastizell. Min. 2-inch ISO 95+ GL Pliodeck SECUROCK Gypsum -Fiber Pliodeck Duro-Tuff / SB IV or WB II _105.0 Roof Board Ashland Min. 0.25-inch Ashland Structural Min. 200 psi, min. 2-inch thick Duro-Last, Duro-Last EV or LWC-22. Min. 2-inch ISO 95+ GL Pliodeck, 6- SECUROCK Gypsum -Fiber Pliodeck, 6-inch -187.5 concrete Elastizell. Duro-Tuff /SB IV or WB II inch o.c. Roof Board D.C. Structural Min. 200 psi, min. 2-inch thick (Optional) Additional LWC-23. Min. 1.5-inch ACFoam 11, Duro-Guard ISO II -A CR-20 CR-20 Duro-Last / WB 1 -82.5 concrete Elastizell layers of base insulation Structural Min. 200 psi, min. 2-inch thick Min. 1.5-inch ACFoam 11, Duro-Guard ISO 11-A, Min. 0.25-inch Duro-Last, Duro-Last EV or LWC-24. H-Shield, Duro-Guard ISO II-H, ENRGY 3 or CR-20 SECUROCK Gypsum -Fiber CR-20 -180.0 concrete Elastizell Duro-Tuff / SB IV or WB 11 Duro-Guard ISO II-G Roof Board DURO-FLEECE AND DURO-FLEECE PLUS MEMBRANE APPLICATIONS: Min. 0.25-inch Duro-Fleece or Duro- Structural Min. 200 psi, min. 2-inch thick Ashland Ashland LWC-25. Min. 2-inch ISO 95+ GL SECUROCK Gypsum -Fiber Fleece Plus / Duro-Fleece -105.0 concrete Elastizell. Pliodeck Roof Board Pliodeck CR-20 (splatter) or WB 11 Ashland Min. 0.25-inch Ashland Duro-Fleece or Duro- LWC-26. Structural Min. 200 psi, min. 2-inch thick Min. 2-inch ISO 95+ GL Pliodeck, 6- SECUROCK Gypsum -Fiber Pliodeck, 6-inch Fleece Plus / Duro-Fleece -187.5 concrete Elastizell. inch o.c. Roof Board O.C. CR-20 (splatter) or WB 11 Structural Min. 200 psi, min. 2-inch thick Min. 1.5-inch ACFoam 11, Duro-Guard ISO 11-A, Min. 0.25-inch Duro-Fleece or Duro- LWC-27. Elastizell H-Shield, Duro-Guard ISO II-H, ENRGY 3 or CR-20 SECUROCK Gypsum -Fiber CR-20 Fleece Plus / Duro-Fleece 180.0 concrete Duro-Guard ISO 11-G Roof Board CR-20 (splatter) or WB 11 MEARLCRETE (FL13492): BAREBACK MEMBRANE APPLICATIONS' Structural Min. 200 psi, min. 2-inch thick (Optional) Additional LWC-28. concrete Mearlcrete Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A CR-20 layers of base insulation CR-20 Duro-Last / WB 1 -82.5 Structural Min. 200 psi, min. 2-inch thick Min. 1.5-inch ACFoam II, Duro-Guard 150 11-A, Min. 0.25-inch Duro-Last, Duro-Last EV or LWC-29. concrete Mearlcrete H-Shield, Duro-Guard ISO II-H, ENRGY 3 or CR-20 SECUROCK Gypsum -Fiber CR-20 Duro-Tuff / SB IV or WB II -240.0 Duro-Guard ISO 11-G Roof Board DURO-FLEECE AND DURo-FLEECE PLUS MEMBRANE APPLICATIONS: - - Structural Min. 200 psi, min. 2-inch thick Min. 1.5-inch ACFoam 11, Duro-Guard 150 II -A, Min. 0.25-inch Duro-Fleece or Duro- LWC-30. H-Shield, Duro-Guard ISO 11-H, ENRGY 3 or CR-20 SECUROCK Gypsum -Fiber CR-20 Fleece Plus / Duro-Fleece -240.0 concrete Mearlcrete Duro-Guard ISO II-G Roof Board CR-20 (splatter) or WB II NEMO ETC, LLC Evaluation Report D9750.05.08-1110 for FL1559-1113 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 32 of 44 ONEMOletc. CONCRETETABLE 4C: LIGHTWEIGHT OVER STEEL . CONSTRUCTION ...... . SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System Deck (Note 1)7- LWC (Note 15) Base Sheet Roof Cover (Note 16) MDP (psf) No. Type Fasteners Attach ELASTIZELL (FL4994): Min. 22 ga., type BV, Grade Min. 320 psi, min. 2-inch thick CertainTeed Flexiglas 7.5-inch o.c. at the 3-inch laps and 7.5- Duro-Fleece or Duro- Fleece Plus / Duro- LWC-31. 33 steel at max. 7 ft spans Elastizell cellular lightweight concrete Base Sheet, GAFGLAS Trufast FM-90 inch o.c. in one staggered row in the Fleece CR-20 (splatter 22.5 cast with Zell Fibers in the mix. #75 center of the sheet applied) Min. 22 ga., type BV, Grade Min. 380 psi, min. 2-inch thick CertainTeed Plexiglas Trufast Twin- 7.5-inch o.c. at the 3-inch laps and 7.5- Duro-Fleece or Duro- Fleece Plus / Duro- LWC-32. 33 steel at max. 7 ft spans Elastizell cellular lightweight concrete Base Sheet, GAFGLAS Loc Nails (min. inch o.c. in one staggered row in the Fleece CR-20 (splatter -37.5 cast with Zell Fibers in the mix. #75, JM PermaPly 28 1.8-in) center of the sheet applied) Min. 350 psi, min. 2-inch thick CertainTeed Plexiglas Trufast Twin- 7.5-inch o.c. at the 3-inch laps and 7.5- Duro-Fleece or Duro- LWC-33. Min. 22 ga., type BV, Grade Elastizell cellular lightweight concrete Base Sheet, GAFGLAS Loc Nails (min. inch o.c. in two, equally spaced, Fleece Plus / Duro- 67.5 33 steel at max. 7 ft spans cast with Zell Fibers in the mix. #75, JM PermaPly 28 1.8-in) staggered row in the center of the Fleece CR-20 (splatter sheet I applied) TABLE 4D: LIGHTWEIGHT CONCRETE OVER STEEL DECKS - NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE F: NON -INSULATED, BONDED ROOF COVER System Deck (Note 1) No. LWC (Note 15) Roof Cover (Note 16) MDP (psf) CELCORE(FL2037): LWC-34. Min. 22 ga., type BV, Grade 33 Min. 350 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture, Duro-Fleece or Duro-Fleece Plus / steel deck at max. 4 ft spans with optional 1-inch thick, 1.0 pcf EPS holey board and surfacing of Celcore PVA Curing Compound. Duro-Fleece Adhesive 37.5 LWC-35. Min. 22 ga., type BV, Grade 33 Min. 350 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture, Duro-Fleece or Duro-Fleece Plus / WB II -60.0 steel deck at max. 6 ft spans with optional 1-inch thick, 1.0 pcf EPS holey board and surfacing of Celcore PVA Curing Compound. ELASTIZELL (FL4994): LWC-36. Min. 22 ga., type BV, Grade 33 Min. 350 psi, min. 2-inch thick Elastizell cellular lightweight concrete cast with Zell Fibers in the mix. Duro-Fleece or Duro-Fleece Plus / -52.5 steel at max. 7 ft spans Duro-Fleece CR-20 (splatter applied) TABLE 4E: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE F: NON -INSULATED, BONDED ROOF COVER System Deck (Note 1) No. LWC (Note 15) 7 Roof Cover (Note 16) MDP (psf) CELCORE(FL2037): LWC-37. Min. 2,500 psi structural concrete Min. 350 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture, Duro-Fleece or Duro-Fleece Plus / 82.5 with optional 1-inch thick, 1.0 pcf EPS holey board and surfacing of Celcore PVA Curing Compound. WB II LWC-38. Min. 2,500 psi structural concrete Min. 350 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture, Duro-Fleece or Duro-Fleece Plus / 232.5 with optional 1-inch thick, 1.0 pcf EPS holey board and surfacing of Celcore PVA Curing Compound. Duro-Fleece Adhesive at 4-inch o.c. NEMO ETC, LLC Certificate of Authorization #32455 02019 NEMO ETC, LLC 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Duro-Last Single Ply Roof Systems; (800) 248-0280 Evaluation Report D9750.05.08-R10 for FL1559-R13 Revision 10: 10/17/2019 Appendix 1, Page 33 of 44 ONEMOjetc System Deck Base Insulation Layer Top Insulation Layer No. (Notes 1 & 12) Type Attach Type Attach (Notes 6 & 7) Roof Cover (Note 16) MDP (psf) CWF-1. Existing min. 2.5-inch Tectum Min. 0.25-inch SECUROCK Insta-Stik, 6- None N/A Duro-Last, Duro-Last EV or Duro-Tuff / SB -150.0 Plank or Tectum LS Plank Gypsum -Fiber Roof Board inch o.c. IV or WB II CWF-2. Existing min. 2.5-inch Tectum Min. 0.25-inch SECUROCK Insta-Stik, 6- None N/A Dura-Fleece or Duro-Fleece Plus / Duro- 150.0 Plank or Tectum LS Plank Gypsum -Fiber Roof Board inch o.c. Fleece CR-20 (splatter) or WB II TABLE 59: • ••r FIBER •CONSTRUCTION,••• • OR RECOVER SYSTEM TYPE • r INSULATION,ROOF COVER Insulation (Note 14) Roof Cover System Deck (Note 1) Attach MDP No. Type Membrane Fasteners Attach (psf) (Note 5) CWF-3. Min. 3-inch One or more layers, any Prelim. Duro-Last, min. Duro-Last Auger Fastener (min. 2-inch Standard Lao System fastened 6-inch o.c. within 6-inch wide Tectum I combination, min. 1.5-inch attach 40-mil embedment) with 2" Auger Plate tabs spaced 57-inch o.c. 45.0 CWF-4. Min. 3-inch One or more layers, any Prelim. Duro-Last, min. Duro-Last Auger Fastener (min. 2-inch Duro-Roof Lao System fastened 6-inch o.c. within 6-inch wide Tectum I combination, min. 1.5-inch attach 40-mil embedment) with 2" Auger Plate tabs spaced 57-inch o.c. Tab Sealer 4725 at max. 60 ft2/gal -52.5 TABLE SC: CEIVIENTITIOUS WOOD FIBER •CONSTRUCTION,••• • • OR RECOVER SYSTEM TYPE E-1: • • MECHANICALLY ATTACHED ROOF COVER Roof Cover System Deck (Note 1) MDP Fasteners No. Membrane Attach (psf) Type ENERFOAM Installation CWF-5. Min. 2-inch Duro-Last, Duro-Last Auger Fastener (min. 2- N/A Standard Lai) System fastened 6-inch o.c. at 3-inch wide Tectum I min. 40-mil inch embedment) tabs spaced 60-inch o.c. -30.0 Min. inch Duro-Last, Duro-Last Auger Fastener (min. 2- 7/16-inch diameter x 2.5-inch deep pilot halt filled with Standard Lai) System fastened 6-inch o.c. at 3-inch wide CWF-6. inch embedment) with 2" Auger Dupont ENERFOAM followed by fastener installation within -37.5 Tectum I min. 40-mil Plate and Dupont ENERFOAMTM 20-40 seconds after dispensing the foam tabs spaced 60-inch o.c. NEMO ETC, LLC Evaluation Report D9750.05.08-R10 for F1.3559-1133 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 34 of 44 ONEMOletc. TABLE 6A: GYPSUM DECKS - REROOF (TEAR -OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Base Insulation Layer Top Insulation Layer System Deck (Notes 1 & 12) Attach Attach Roof Cover (Note 16) � No. Type Type Ps (Notes 6 & 7) (Notes 6 & 7) BAREBACK MEMBRANE APPLICATIONS: G-1. Existing poured gypsum (Optional) Min. 1.5-inch ACFoam II, CR-20 Min. 0.25-inch Dens Deck CR-20 Duro-Last / WB 1 -37.5 or gypsum plank Duro-Guard ISO II -A G 2 Existing poured gypsum Min. 1.5-inch ACFoam II, Duro-Guard CR-20 (Optional) Additional layers of base insulation CR-20 Duro-Last / SB I or WB II -45.0 or gypsum plank ISO II -A G-3. Existing poured gypsum Min. 1.5-inch ACFoam II, Duro-Guard CR-20 (Optional) Additional layers of base insulation CR-20 Duro-Last, Duro-Last EV or -45.0 or gypsum plank ISO II -A Duro-Tuff / SB IV or WB II G-4. Existing poured gypsum Min. 1.5-inch ACFoam 11, Duro-Guard CR-20 (Optional) Additional layers of base insulation CR-20 Duro-Last / WB 1 -82.5 or gypsum plank ISO II -A Existing poured gypsum Min. 1.5-inch ACFoam II, Duro-Guard Duro-Last, Duro-Last EV or G-5. or gypsum plank ISO II -A, H-Shield, Duro-Guard ISO II-H, CR-20 Min. 0.25-inch SECUROCK Gypsum -Fiber Roof Board CR-20 Duro-Tuff / SB IV or WB II -247.5 ENRGY 3 or Duro-Guard ISO II-G DURO-FLEECE OR DURO-FLEECE PLUS MEMBRANE APPLICATIONS: G-6. Existing poured gypsum Min. 1.5-inch ACFoam 11, Duro-Guard CR-20 (Optional) Additional layers of base insulation CR-20 Duro-Fleece or Duro-Fleece -45.0 or gypsum plank ISO II -A Plus / WB II Existing poured gypsum Min. 1.5-inch ACFoam II, Duro-Guard Duro-Fleece or Duro-Fleece G 7. or gypsum plank ISO II -A, H-Shield, Duro-Guard ISO II-H, CR-20 Min. 0.25-inch SECUROCK Gypsum -Fiber Roof Board CR-20 Plus / Duro-Fleece CR-20 -247.5 ENRGY 3 or Duro-Guard ISO II-G (splatter) or WB II Existing poured gypsum Min. 1.5-inch ACFoam II, Duro-Guard Trufast Min. 0.5-inch Duro-Guard ISO HD -A or Duro-Guard ISO Trufast Duro-Fleece or Duro-Fleece G 8 or gypsum plank 150 II -A, ENRGY 3 CGF, Duro-Guard ISO Roofing HD-H Roofing Plus / Trufast Roofing -165.0 III-G, H-Shield CG, Duro-Guard ISO III-H Adhesive Adhesive Adhesive, ribbons 4" o.c. Min. 1.5-inch ACFoam II, Duro-Guard Trufast Min. 0.25-inch Dens Deck, Dens Deck Prime, DEXcell FA Trufast Duro-Fleece or Duro-Fleece G 9 Existing poured gypsum ISO II -A, ENRGY 3 CGF,-Duro-Guard ISO Roofing Glass Mat Roof Board, SECUROCK Gypsum -Fiber Roof Roofing Plus / Trufast Roofing -195.0 or gypsum plank III-G, H-Shield CG, Duro-Guard ISO III-H Adhesive Board or SECUROCK Glass -Mat Roof Board or min. Adhesive Adhesive, ribbons 4" o.c. 7/16" DEXcell Cement Roof Board Existing poured gypsum Min. 1.5-inch ACFoam II, Duro-Guard Trufast Trufast Duro-Fleece or Duro-Fleece G-10. or gypsum plank ISO II -A, ENRGY 3 CGF, Duro-Guard ISO Roofing (Optional) Additional layers of base insulation Roofing Plus /Trufast Roofing -217.5 III-G, H-Shield CG, Duro-Guard ISO III-H Adhesive I Adhesive Adhesive, ribbons 4" o.c. System Deck Insulation Roof Cover No. (Note 1) Type Attach Membrane Fasteners (Note 11) MDP (psf) Attach . Existing poured gypsum One or more layers, G-11. Prelim. Duro-Last, min. 40 mil, Duro-Last Auger Fastener Standard Lao Svstem fastened 6-inch o.c. within 6-inch wide 45.0 or gypsum plank any combination Attached with 2" Auger Plate tabs spaced 57-inch o.c. G-12. Existing poured gypsum One or more layers, Prelim. Duro-Last, min. 40 mil, Duro-Last Auger Fastener Duro-Roof Lao System fastened 6-inch o.c. within 6-inch wide -60.0 or gypsum plank any combination attached with 2" Auger Plate tabs spaced 57-inch o.c. Tab Sealer 4725 at max. 60 ft2/gal NEMO ETC, LLC Evaluation Report D9750.05.08-1110 for FL3559-1113 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 35 of 44 ONEMOjetc. TABLE SYSTEM TYPE A: BONDED INSULATION, BONDED ROOF COVER Base Insulation Layer Top Insulation Layer System Substrate MDP Attach Attach Roof Cover (Note 16) No. (Notes 1 & 12) Type Type (psf) (Notes 6 & 7) (Notes 6 & 7) BAREBACK MEMBRANE. APPLICATIONS: - R-1. Existing asphaltic BUR or mineral (Optional) Min. 1.5-inch ACFoam II, Duro- Ashland Pliodeck, Min. 0.25-inch Dens Deck Ashland Pliodeck, Duro-Last / WB 1 -37.5 surface cap sheet Guard 150 II -A 6-inch o.c 6-inch o.c R 2 Existing asphaltic BUR or mineral Min. 1.5-inch ACFoam 11, Duro-Guard ISO 11-A Ashland Pliodeck, (Optional) Additional layers Ashland Pliodeck, Duro-Last / SB I or WB 11 -45.0 surface cap sheet 6-inch o.c of base insulation 6-inch o.c R-3. Existing asphaltic BUR or mineral Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A Ashland Pliodeck, (Optional) Additional layers Ashland Pliodeck, Duro-Last, Duro-Last EV or -45.0 surface cap sheet 6-inch o.c of base insulation 6-inch o.c Duro-Tuff / SB IV or WB 11 R-4. Existing asphaltic BUR or mineral Min. 1.5-inch ACFoam II, Duro-Guard I50 II -A Ashland Pliodeck, (Optional) Additional layers Ashland Pliodeck, Duro-Last / WB I 82.5 surface cap sheet 6-inch o.c of base insulation 6-inch o.c R-5. Existing asphaltic BUR or mineral Min. 2-inch ISO 95+ GL Ashland Pliodeck, Min. 0.25-inch SECUROCK Ashland Pliodeck, Duro-Last, Duro-Last EV or 172.5 surface cap sheet 6-inch o.c. Gypsum -Fiber Roof Board 6-inch o.c. Duro-Tuff / 5B IV or WB II Existing asphaltic BUR or mineral (Optional) Min. 1.5-inch ACFoam 11, Duro- R-6. surface cap sheet Guard 150 II -A Board -Max Min. 0.25-inch Dens Deck Board -Max Duro-Last / WB 1 -37.5 R 7 Existing asphaltic BUR or mineral Min. 1.5-inch ACFoam 11, Duro-Guard ISO II -A Board -Max (Optional) Additional layers Board -Max Duro-Last / SB I or WB II-45.0 surface cap sheet of base insulation R-8. Existing asphaltic BUR or mineral Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A Board -Max (Optional) Additional layers Board -Max Duro-Last, Duro-Last EV or -45.0 surface cap sheet of base insulation Duro-Tuff / 5B IV or WB 11 R 9 Existing asphaltic BUR or mineral Min. 1.5-inch ACFoam 11, Duro-Guard ISO II -A Board -Max (Optional) Additional layers Board -Max Duro-Last / WB 1 -82.5 surface cap sheet of base insulation R-10. Existing smooth surface BUR or Min. 0.25-inch SECUROCK Gypsum -Fiber Board -Max None N/A Duro-Last, Duro-Last EV or -245.0 granule surface modified bitumen Roof Board Duro-Tuff / SB IV or WB II Existing smooth surface BUR or Min. 1.5-inch ACFoam 11, Duro-Guard 150 11- Min. 0.25-inch SECUROCK Duro-Last, Duro-Last EV or R-11. granule surface modified bitumen A, H-Shield, Duro-Guard ISO II-H, ENRGY 3 or Board -Max Gypsum -Fiber Roof Board Board -Max Duro-Tuff / SB IV or WB II -247.5 Duro-Guard ISO 11-G Existing smooth -surface asphalt R-12. BUR or granule -surface modified Min. 0.75-inch Duro-Guard EPS Type IX Board -Max Min. Board -Max Duro-Last, Duro-Last EV or -247.5 bitumen m-Finch Roof Board Gypsum -Fiber Roof Board Duro-Tuff / SB IV or WB II Existing smooth -surface asphalt R-13. BUR or granule -surface modified Min. 0.75-inch Duro-Guard EPS Type IX Board -Max Min. Board -Max Duro-Last, Duro Last EV or -255.0 bitumen m-Finch Roof Board Gypsum -Fiber Roof Board Duro-Tuff / SB IV or WB II Existing asphaltic BUR or mineral (Optional) Min. 1.5-inch ACFoam 11, Duro- R-14. surface cap sheet Guard ISO II -A CR-20 Min. 0.25-inch Dens Deck CR 20 Duro-Last / WB I 37.5 R-15. Existing asphaltic BUR or mineral Min. 1.5-inch ACFoam 11, Duro-Guard ISO II -A CR-20 (Optional) Additional layers CR-20 Duro-Last / SB I or WB 11 -45.0 surface cap sheet of base insulation R-16. Existing asphaltic BUR or mineral Min. 1.5-inch ACFoam II, Duro-Guard ISO 11-A CR-20 (Optional) Additional layers CR-20 Duro-Last, Duro-Last EV or -45.0 surface cap sheet of base insulation Duro-Tuff / 5B IV or WB II NEMO ETC, LLC Evaluation Report D9750.05.08-1110 for FL1559-R33 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 36 of 44 ONEMOjetc. TABLE7A: RECOVER APPLICATIONS SYSTEM TYPE A: BONDED INSULATION, BONDED ROOF Base Insulation Layer Top Insulation Layer System Substrate Roof Cover (Note 16) MDP Attach Attach No. (Notes 1 & 12) Type Type (psf) (Notes 6 & 7) (Notes 6 & 7) R-17. Existing asphaltic BUR or mineral Min. 1.5-inch ACFoam II, Duro-Guard 150 II -A CR-20 (Optional) Additional layers CR-20 Duro-Last / WB 1 -82.5 surface cap sheet of base insulation Existing smooth surface modified (Optional) Min. 1.5-inch ACFoam II, Duro- Min. 0.25-inch SECUROCK Duro-Last, Duro-Last EV or R-18. bitumen Guard ISO II -A, H-Shield, Duro-Guard ISO II- CR-20 Gypsum -Fiber Roof Board CR-20 Duro-Tuff / SB IV or WB II 222 5 H, ENRGY 3 or Duro-Guard ISO II-G Existing smooth -surface SBS Min. 0.75-inch Duro-Guard EPS Type II, VIII Min. 0.25-inch SECUROCK Duro-Last, Duro-Last EV or R-19. modified bitumen or IX CR-20 Gypsum -Fiber Roof Board CR-20 Duro-Tuff / SB IV or WB II 222.5 R-20. Existing smooth surface BUR or Min. 0.25-inch SECUROCK Gypsum -Fiber CR-20 None N/A Duro-Last, Duro-Last EV or granule surface modified bitumen Roof Board Duro-Tuff / SB IV or WB II -245.0 Min. 1.5-inch ACFoam 11, Duro-Guard ISO II- R-21. Existing smooth surface BUR or A, H-Shield, Duro-Guard 150 11-H, ENRGY 3 or CR-20 Min. 0.25-inch SECUROCK CR-20 Duro-Last, Duro-Last EV or -247.5 granule surface modified bitumen Gypsum -Fiber Roof Board Duro-Tuff / SB IV or WB II Duro-Guard 150 II-G Existing smooth -surface asphalt Min. 0.75-inch Duro-Guard EPS Type II, VIII Min. 0.25-inch SECUROCK Duro-Last, Duro-Last EV or R-22. BUR or granule -surface modified or IX CR-20 Gypsum -Fiber Roof Board CR-20 Duro-Tuff / SB IV or WB II 247.5 bitumen Existing smooth -surface asphalt Min. 0.75-inch Duro-Guard EPS Type II, VIII Min. 0.25-inch SECUROCK Duro-Last, Duro-Last EV or R-23. BUR or granule -surface modified or IX CR-20 Gypsum -Fiber Roof Board CR-20 Duro-Tuff / SB IV or WB II -255.0 bitumen R 24 Existing asphaltic BUR or mineral Min. 1.5-inch ACFoam 11, Duro-Guard ISO II -A Hot asphalt (Optional) Additional layers Hot asphalt Duro-Last / SB I or WB II -45.0 surface cap sheet of base insulation R-25. Existing asphaltic BUR or mineral Min. 1.5-inch ACFoam II, Duro-Guard 150 II -A Hot asphalt (Optional) Additional layers Hot asphalt Duro-Last, Duro-Last EV or -45.0 surface cap sheet of base insulation Duro-Tuff / SB IV or WB II Existing asphaltic BUR or mineral (Optional) Additional layers R-26. surface cap sheet Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A Hot asphalt of base insulation Hot asphalt Duro-Last / WB 1 -75.0 Existing asphaltic BUR or mineral (Optional) Min. 1.5-inch ACFoam II, Duro- R 27. surface cap sheet Guard ISO II -A Insta-Stik Min. 0.25-inch Dens Deck Insta-Stik Duro-Last / WB I 37.5 Existing asphaltic BUR or mineral (Optional) Additional layers R-28. surface cap sheet Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A Insta-Stik of base insulation Insta-Stik Duro-Last / SB I or WB II 45.0 R 29. Existing asphaltic BUR or mineral Min. 1.5-inch ACFoam II, Duro-Guard ISO II A Insta-Stik (Optional) Additional layers Insta-Stik Duro-Last, Duro-Last EV or 45.0 surface cap sheet of base insulation Duro-Tuff / SB IV or WB II R-30. Existing asphaltic BUR or mineral Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A Insta-Stik (Optional) Additional layers Insta-Stik Duro-Last / WB I 82.5 surface cap sheet of base insulation Min. 1.5-inch ACFoam II, Duro-Guard ISO II- R-31. Existing asphaltic BUR or mineral A, H-Shield, Duro-Guard I50 II-H, ENRGY 3 or Insta-Stik Min. O.ZS-inch SECUROCK Insta-Stik Duro-Last, Duro-Last EV or -127.5 surface cap sheet Duro-Guard ISO II-G Gypsum Fiber Roof Board Duro-Tuff / SB IV or We II NEMO ETC, LLC Certificate of Authorization #32455 - ©2019 NEMO ETC, LLC 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Duro-Last Single Ply Roof Systems; (800) 248-0280 Evaluation Report D9750.05.08-1110 for F1.3559-1113 Revision 10: 10/17/2019 Appendix 1, Page 37 of 44 ONEMOjetc. APPLICATIONSTABLE 7A: RECOVER SYSTEM TYPE A: BONDED INSULATION, BONDED ROOF COVER Base Insulation Layer Top Insulation Layer System Substrate Roof Cover (Note 16) MDP Attach Attach No. (Notes 1 & 12) Type Type (psf) (Notes 6 & 7) (Notes 6 & 7) R-32. Existing asphalt built-up roof (Optional) Min. 1.5-inch ACFoam 11, Duro- OlyBond 500 Min. 0.25-inch Dens Deck OlyBond 500 Duro-Last / WB 1 -37.5 Guard 150 II -A R-33. Existing asphalt built-up roof (Optional) Min. 1.5-inch ACFoam 11, Duro- OlyBond 500 (Optional) Additional layers OlyBond 500 Duro-Last / SB I or WB II -45.0 Guard ISO II -A of base insulation R-34. Existing asphalt built-up roof (Optional) Min. 1.5-inch ACFoam 11, Duro- OlyBond 500 (Optional) Additional layers OlyBond 500 Duro-Last, Duro-Last EV or -45.0 Guard ISO II -A of base insulation Duro-Tuff / SB IV or WB II R-35. Existing asphalt built-up roof Min. 1.5-inch ACFoam 11, Duro-Guard ISO II -A OlyBond 500 (Optional) Additional layers OlyBond 500 Duro-Last / WB 1 -82.5 of base insulation (Optional) Min. 1.5-inch ACFoam 11, Duro- Min. 0.25-inch SECUROCK Duro-Last, Duro-Last EV or R-36. Existing asphalt built-up roof Guard ISO II -A, H-Shield, Duro-Guard ISO 11- OlyBond 500 Gypsum -Fiber Roof Board OlyBond 500 Duro-Tuff / 513 IV or WB II -120.0 H, ENRGY 3 or Duro-Guard ISO II-G DURO-FLEECE OR DURo-FLEECE PLUS MEMBRANE APPLICATIONS: R-37. Existing asphaltic BUR or mineral Min. 1.5-inch ACFoam II, Duro-Guard ISO 11-A Ashland Pliodeck, (Optional) Additional layers Ashland Pliodeck, Duro-Fleece or Duro-Fleece -45.0 surface cap sheet 6-inch o.c of base insulation 6-inch o.c Plus / WB II Existing asphaltic BUR or mineral Ashland Pliodeck, Min. 0.25-inch SECUROCK Ashland Pliodeck, Duro-Fleece or Duro-Fleece R-38. surface cap sheet Min. 2-inch ISO 95+ GL 6-inch o.c. Gypsum -Fiber Roof Board 6-inch o.c. Plus / Duro-Fleece CR-20 -172.5 (splatter) or WB 11 R-39. Existing asphaltic BUR or mineral Min. 1.5-inch ACFoam 11, Duro-Guard ISO 11-A Board -Max (Optional) Additional layers Board -Max Duro-Fleece or Duro-Fleece -45.0 surface cap sheet of base insulation Plus / WB II Existing smooth surface BUR or Min. 0.25-inch SECUROCK Gypsum -Fiber Duro-Fleece or Duro-Fleece R-40. granule surface modified bitumen Roof Board Board -Max None N/A Plus / Duro-Fleece CR-20 -245.0 (splatter) or WB 11 Existing smooth surface BUR or Min. 1.5-inch ACFoam 11, Duro-Guard ISO 11- Min. 0.25-inch SECUROCK Duro-Fleece or Duro-Fleece R-41. granule surface modified bitumen A, H-Shield, Duro-Guard ISO 11-H, ENRGY 3 or Board -Max Gypsum -Fiber Roof Board Board -Max Plus / Duro-Fleece CR-20 -247.5 Duro-Guard ISO 11-G (splatter) or WB II Existing smooth -surface asphalt Min. 0.25-inch SECUROCK Duro-Fleece or Duro-Fleece R-42. BUR or granule -surface modified Min. 0.75-inch Duro-Guard EPS Type IX Board -Max Gypsum -Fiber Roof Board Board -Max Plus / Duro-Fleece CR-20 -247.5 bitumen (splatter) or WB 11 Existing smooth -surface asphalt Min. 0.25-inch SECUROCK Duro-Fleece or Duro-Fleece R-43. BUR or granule -surface modified Min. 0.75-inch Duro-Guard EPS Type IX Board -Max Board -Max Plus / Duro-Fleece CR-20 -255.0 bitumen Gypsum -Fiber Roof Board (splatter) or WB 11 R-44. Existing asphaltic BUR or mineral Min. 1.5-inch ACFoam 11, Duro-Guard ISO II -A CR-20 (Optional) Additional layers CR-20 Duro-Fleece or Duro-Fleece -45.0 surface cap sheet of base insulation Plus / WB II Existing smooth surface modified (Optional) Min. 1.5-inch ACFoam 11, Duro- Min. 0.25-inch SECUROCK Duro-Fleece or Duro-Fleece R-45. bitumen Guard ISO 11-A, H-Shield, Duro-Guard ISO II- CR-20 Gypsum -Fiber Roof Board CR-20 Plus / Duro-Fleece CR-20 -222.5 H, ENRGY 3 or Duro-Guard ISO II-G (splatter) or WB II NEMO ETC, LLC Evaluation Report D9750.05.08-1110 for FL3559-1113 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 38 of 44 ONEMOletc. TABLE7A: RECOVER APPLICATIONS SYSTEM TYPE A: BONDED INSULATION, BONDED ROOF COVER Base Insulation Layer Top Insulation Layer System Substrate MDP Type Attach Type Attach No. (Notes 1 & 12) Roof Cover (Note 16) (psf) (Notes 6 & 7) (Notes 6 & 7) Existing smooth -surface SBS Min. 0.75-inch Duro-Guard EPS Type II, VIII Min. 0.25-inch SECUROCK Duro-Fleece or Duro-Fleece R-46. CR-20 CR-20 Plus / Duro-Fleece CR-20 -222.5 modified bitumen or IX Gypsum -Fiber Roof Board (splatter) or WB II Existing smooth surface BUR or Min. 0.25-inch SECUROCK Gypsum -Fiber Duro-Fleece or Duro-Fleece R 47. CR-20 None N/A Plus / Duro-Fleece CR-20 -245.0 granule surface modified bitumen Roof Board (splatter) or WB II Existing smooth surface BUR or Min. 1.5-inch ACFoam Il, Duro-Guard ISO II- Min. 0.25-inch SECUROCK Duro-Fleece or Duro-Fleece R-48. granule surface modified bitumen A, H-Shield, Duro-Guard ISO II-H, ENRGY 3 or CR-20 Gypsum -Fiber Roof Board CR-20 Plus / Duro-Fleece CR-20 -247.5 Duro-Guard ISO II-G (splatter) or WB II Existing smooth -surface asphalt Duro-Fleece or Duro-Fleece R-49. BUR or granule -surface modified Min. 0.75-inch Duro-Guard EPS Type II, VIII CR-20 Min. 0.25-inch SECUROCK CR-20 Plus / Duro-Fleece CR-20 -247.5 bitumen or IX Gypsum -Fiber Roof Board (splatter) or WB II Existing smooth -surface asphalt Min. 0.75-inch Duro-Guard EPS Type II, VIII Min. 0.25-inch SECUROCK Duro-Fleece or Duro-Fleece R-50. BUR or granule -surface modified CR-20 CR-20 Plus / Duro-Fleece CR-20 -255.0 bitumen or IX Gypsum -Fiber Roof Board (splatter) or WB II Existing asphaltic BUR or mineral (Optional) Additional layers Duro-Fleece or Duro-Fleece R-51. surface cap sheet Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A Hot asphalt of base insulation Hot asphalt Plus / WB II -45.0 Existing asphaltic BUR or mineral (Optional) Additional layers Duro-Fleece or Duro-Fleece R-52. surface cap sheet Min. 1.5-inch ACFoam II, Duro-Guard ISO II -A Insta-Stik of base insulation Insta-Stik Plus / WB II 45 0 Existing asphaltic BUR or mineral Min. 1.5-inch ACFoam II, Duro-Guard ISO II- Min. 0.25-inch SECUROCK Duro-Fleece or Duro-Fleece R-53. surface cap sheet A, H-Shield, Duro-Guard ISO II-H, ENRGY 3 or Insta-Stik Gypsum -Fiber Roof Board Insta-Stik Plus / Duro-Fleece CR-20 -127.5 Duro-Guard ISO II-G (splatter) or WB II R-54. Existing asphalt built-up roof (Optional) Min. 1.5-inch ACFoam II, Duro- OlyBond 500 (Optional) Additional layers OlyBond 500 Duro-Fleece or Duro-Fleece -45.0 Guard ISO II -A of base insulation Plus / WB II (Optional) Min. 1.5-inch ACFoam II, Duro- Duro-Fleece or Duro-Fleece R-55. Existing asphalt built-up roof Guard ISO II -A, H-Shield, Duro-Guard ISO II- OlyBond 500 Min. 0.25-inch SECUROCK OlyBond 500 Plus / Duro-Fleece CR-20 120.0 H, ENRGY 3 or Duro-Guard ISO II-G Gypsum -Fiber Roof Board (splatter) or WB II NEMO ETC, LLC Certificate of Authorization #32455 - ©2019 NEMO ETC, LLC 0' EDITION (2017) FBC NON-HVHZ EVALUATION Duro-Last Single Ply Roof Systems; (800) 248-0280 Evaluation Report D9750.05.08-R10 for FL3559-1113 Revision 10: 10/17/2019 Appendix 1, Page 39 of 44 ONEMOjeic. RECOVEROVER STEEL SUBSTRATE PLATE-BONDEDSYSTEM TYPE C-2: ROOF COVER (All areas where the existing metal panels do not lay flush on the underlying purlin shall have a 0.25-inch diameter pilot hole pre -drilled into the panel priorto driving the Purlin Fastener into the purlin.) System Substrate Attachment MDP Insulation Layer Roof Cover No. (Note 1) Fasteners (Note 11) Spacing (psf) RHINOBOND INDUCTION WELD: Existing standing seam or lap seam metal roof covers One or more layers, any Trufast #12 Purlin Fasteners Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) R-56, having min. 16 gauge (0.0598 inch), 50 ksi or min. 12 gauge combination, with RHINOBOND Insulation 12-Inch o.c. along or Duro-Tuff (min. 80-mil) induction welded to -30.0 (0.105 in.), 36 ksi steel purlins spaced max. 60-inch o.c. preliminarily fastened Plate (PVC) purlins 60-inch o.c. RHINOBOND Insulation Plate (PVC) using RHINOBOND Installation Tool Existing standing seam or lap seam metal roof covers One or more layers, any Trufast #12 Purlin Fasteners Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) R-57. having min. 16 gauge (0.0598 inch), 50 ksi or min. 12 gauge combination, with RHINOBOND Insulation 6-inch o.c. along or Duro-Tuff (min. 80-mil) induction welded to -45.0 (0.105 in.), 36 ksi steel purlins spaced max. 120-inch o.c. preliminarily fastened Plate (PVC) purlins 120-inch o.c. RHINOBOND Insulation Plate (PVC) using RHINOBOND Installation Tool Existing standing seam or lap seam metal roof covers One or more layers, any Trufast #12 Purlin Fasteners Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) R-58. having min. 16 gauge (0.0598 inch), 50 ksi or min. 12 gauge combination, with RHINOBOND Insulation 12-inch o.c. along or Duro-Tuff (min. 80-mil) induction welded to -45.0 (0.105 in.), 36 ksi steel purlins spaced max. 48-inch o.c. preliminarily fastened Plate (PVC) purlins 48-inch o.c. RHINOBOND Insulation Plate (PVC) using RHINOBOND Installation Tool Existing standing seam or lap seam metal roof covers One or more layers, any Trufast #12 Purlin Fasteners Duro-Last (min. 40-mil), Duro-Tuff (min. 50-mil) or R-59. having min. 16 gauge (0.0598 inch), 50 ksi or min. 12 gauge combination, with RHINOBOND Insulation 6-inch o.c. along Duro-Last EV (min. 50-mil) induction welded to -52.5 (0.105 in.), 36 ksi steel purlins spaced max. 72-inch o.c. preliminarily fastened Plate (PVC) purlins 72-inch o.c. RHINOBOND Insulation Plate (PVC) using RHINOBOND Installation Tool Existing standing seam or lap seam metal roof covers One or more layers, any Trufast #12 Purlin Fasteners Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) R-60. having min. 16 gauge (0.0598 inch), 50 ksi or min. 12 gauge combination, with RHINOBOND Insulation 6-inch o.c. along or Duro-Tuff (min. 80-mil) induction welded to -52.5 (0.105 in.), 36 ksi steel purlins spaced max. 96-inch o.c. preliminarily fastened Plate (PVC) purlins 96-inch o.c. RHINOBOND Insulation Plate (PVC) using RHINOBOND Installation Tool Existing standing seam or lap seam metal roof covers One or more layers, any Trufast #12 Purlin Fasteners Duro-Last (min. 40-mil), Duro-Tuff (min. 50-mil) or R-61. having min. 16 gauge (0.0598 inch), 50 ksi or min. 12 gauge combination, with RHINOBOND Insulation 6-inch o.c. along Duro-Last EV (min. 50-mil) induction welded to 82 5 (0.105 in.), 36 ksi steel purlins spaced max. 48-inch o.c. preliminarily fastened Plate (PVC) purlins 48-inch o.c. RHINOBOND Insulation Plate (PVC) using RHINOBOND Installation Tool Existing standing seam or lap seam metal roof covers One or more layers, any Trufast #12 Purlin Fasteners Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) R-62. having min. 16 gauge (0.0598 inch), 50 ksi or min. 12 gauge combination, with RHINOBOND Insulation 6-inch o.c. along or Duro-Tuff (min. 80-mil) induction welded to 82 5 (0.105 in.), 36 ksi steel purlins spaced max. 60-inch o.c. preliminarily fastened Plate (PVC) purlins 60-inch o.c. RHINOBOND Insulation Plate (PVC) using RHINOBOND Installation Tool Existing standing seam or lap seam metal roof covers One or more layers, any Trufast #12 Purlin Fasteners Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) R-63. having min. 16 gauge (0.0598 inch), 50 ksi or min. 12 gauge combination, with RHINOBOND Insulation 6-inch o.c. along or Duro-Tuff (min. 80-mil) induction welded to -90.0 0.105 in. , 36 ksi steel purlins spaced max. 48-inch o.c. ( ) p p preliminarily fastened Plate (PVC) purlins 48-inch o.c. RHINOBOND Insulation Plate (PVC) using RHINOBOND Installation Tool ISOWELD INDUCTION WELD: Existing standing seam or lap seam metal roof covers One or more layers, any SFS Purlin Fastener with Duro-Last (min. 40 mil), Duro-Last EV (min. 50 mil) R-64. having min. 16 gauge (0.0598 inch), 50 ksi steel purlins combination, isoweld® Fl-P-6.8-PVC 12-inch o.c. along or Duro-Tuff (min. 50 mil) induction welded to SFS -45.0 spaced max. 60-inch o.c. preliminarily fastened Plates purlins 60-inch o.c. isoweld® Fl-P-6.8-PVC Plates with SFS isoweld® 3000 stand-up tool NEIVIO ETC, LLC Evaluation Report D9750.05.08-R10 for FL3559-1133 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 @2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 40 of 44 ONEMOjetc. RECOVER OVER STEEL SUBSTRATE PLATE-BONDEDTABLE7B: SYSTEM TYPE C-2: ROOF COVER (All areas where the existing metal panels do not lay flush on the underlying purlin shall have a 0.25-inch diameter pilot hole pre -drilled into the panel priorto drivingthe Purlin Fastener into the purlin.) System Substrate Insulation Layer Attachment Roof Cover MDP No. (Note 1) Fasteners (Note 11) Spacing- (psf) Existing standing seam or lap seam metal roof covers One or more layers, any SFS Purlin Fastener with Duro-Last (min. 40 mil), Duro-Last EV (min. 50 mil) R-65. having min. 16 gauge (0.0598 inch), 50 ksi steel purlins combination, isoweld® Fl-P-6.8-PVC 6-inch o.c. along or Duro-Tuff (min. 50 mil) induction welded to SFS -90.0 spaced max. 60-inch o.c. preliminarily fastened Plates purlins 60-inch o.c. isoweld® Fl-P-6.8-PVC Plates with SFS isoweld® 3000 stand-up tool TRUFAST INDUCTION WELD: Existing standing seam or lap seam metal roof covers . One or more layers, any Duro-Last (min. 40 mil), Duro-Last EV (min. 50 mil) R-66. having min. 16 gauge (0.0598 inch), 50 ksi or min. 12 gauge combination, Trufast #12 Purlin Fastener 12-inch o.c. along or Duro-Tuff (min. 50 mil) induction welded to -45.0 (0.105 in.), 36 ksi steel purlins spaced max. 60-inch o.c. preliminarily fastened with Trufast PVC IW Plate purlins 60-inch o.c. Trufast PVC IW Plates with Trufast Induction Welding Tool and Magnets Existing standing seam or lap seam metal roof covers One or more layers, any Trufast #12 Purlin Fastener 12-inch o.c. along Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) R-67. having min. 16 gauge (0.0598 inch), 50 ksi or min. 12 gauge combination, with Trufast PVC IW Plate purlins 48-inch o.c. induction welded to Trufast PVC IW Plates with -52.5 (0.105 in.), 36 ksi steel purlins spaced max. 48-inch o.c. preliminarily fastened Trufast Induction Welding Tool and Magnets Existing standing seam or lap seam metal roof covers One or more layers, any Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) R-68. having min. 16 gauge (0.0598 inch), 50 ksi or min. 12 gauge combination, Trufast #12 Purlin Fastener 12-inch o.c. along or Duro-Tuff (min. 60 mil) induction welded to -60.0 (0.105 in.), 36 ksi steel purlins spaced max. 48-inch o.c. preliminarily fastened with Trufast PVC IW Plate purlins 48-inch o.c. Trufast PVC IW Plates with Trufast Induction Welding Tool and Magnets Existing standing seam or lap seam metal roof covers One or more layers, any Trufast Fastener 12-inch o.c. along Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) R-69. having min. 16 gauge (0.0598 inch), 50 ksi or min. 12 gauge combination, with Trufast as t PVC IW Plate p.c. urlins 36-inch o.c. induction welded to Trufast PVC IW Plates with -60.0 (0.105 in.), 36 ksi steel purlins spaced max. 36-inch o.c. preliminarily fastened Trufast Induction Welding Tool and Magnets Existing standing seam or lap seam metal roof covers One or more layers, any Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) R-70. having min. 16 gauge (0.0598 inch), 50 ksi or min. 12 gauge combination, Trufast #12 Purlin Fastener 12-inch o.c. along or Duro-Tuff (min. 60 mil) induction welded to -82.5 (0.105 in.), 36 ksi steel purlins spaced max. 36-inch o.c. preliminarily fastened with Trufast PVC IW Plate purlins 36-inch o.c. Trufast PVC IW Plates with Trufast Induction Welding Tool and Magnets Existing standing seam or lap seam metal roof covers One or more layers, any Trufast Purlin Fastener o.c. along Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) R-71. having min. 16 gauge (0.0598 inch), 50 ksi or min. 12 gauge combination, Trufast with Trufast PVC IW Plate purlins 72-inch o.c. purlins induction welded to Trufast PVC IW Plates with -67.5 (0.105 in.), 36 ksi steel purlins spaced max. 72-inch o.c. preliminarily fastened Trufast Induction Welding Tool and Magnets Existing standing seam or lap seam metal roof covers One or more layers, any Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) R-72. having min. 16 gauge (0.0598 inch), 50 ksi or min. 12 gauge combination, Trufast #12 Purlin Fastener 6-inch o.c. along or Duro-Tuff (min. 60 mil) induction welded to -75.0 (0.105 in.), 36 ksi steel purlins spaced max. 72-inch o.c. preliminarily fastened with Trufast PVC IW Plate purlins 72-inch o.c. Trufast PVC IW Plates with Trufast Induction Welding Tool and Magnets Existing standing seam or lap seam metal roof covers One or more layers, any Trufast Purlin Fastener o.c. along Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) R-73. having min. 16 gauge (0.0598 inch), 50 ksi or min. 12 gauge combination, Trufast with Trufast PVC IW Plate purlins 60-inch o.c. purlins induction welded to Trufast PVC IW Plates with -75.0 (0.105 in.), 36 ksi steel purlins spaced max. 60-inch o.c. preliminarily fastened Trufast Induction Welding Tool and Magnets Existing standing seam or lap seam metal roof covers One or more layers, any Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) R-74. havingmin. 16 gauge 0.0598 inch), 50 ksi or min. 12 gauge g g ( ) g g combination, Trufast #12 Purlin Fastener 6-inch o.c. along or Duro-Tuff (min. 60 mil) induction welded to 90.0 (0.105 in.), 36 ksi steel purlins spaced max. 60-inch o.c. preliminarily fastened with Trufast PVC IW Plate purlins 60-inch o.c. Trufast PVC IW Plates with Trufast Induction Welding Tool and Magnets NEIVIO ETC, LLC Certificate of Authorization #32455 - ©2019 NEMO ETC, LLC 6- EDITION (2017) FBC NON-HVHZ EVALUATION Duro-Last Single Ply Roof Systems; (800) 248-0280 Evaluation Report D9750.05.08-R10 for FL1559-1113 Revision 10: 10/17/2019 Appendix 1, Page 41 of 44 ONEMOletc. RECOVER OVER STEEL SUBSTRATE PLATE-BONDEDTABLE7B: SYSTEM TYPE C-2: ROOF COVER fAll areas where the existing metal panels do not lay flush on the underlying purlin shall have a 0.25-inch diameter pilot hole pre -drilled into the panel priorto drivingthe Purlin Fastener into the purlin.) System Substrate Attachment MDP No. (Note 1) Insulation Layer Fasteners (Note 11) Spacing Roof Cover (psf) Existing standing seam or lap seam metal roof covers One or more layers, any Trufast #12 Purlin Fastener 6-inch o.c. along Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) R-75. having min. 16 gauge (0.0598 inch), 50 ksi or min. 12 gauge combination, with Trufast PVC IW Plate purlins 48-inch o.c. induction welded to Trufast PVC IW Plates with -90.0 (0.105 in.), 36 ksi steel purlins spaced max. 48-inch o.c. preliminarily fastened Trufast Induction Welding Tool and Magnets Existing standing seam or lap seam metal roof covers One or more layers, any Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) R-76. having min. 16 gauge (0.0598 inch), 50 ksi or min. 12 gauge combination, Trufast #12 Purlin Fastener 6-inch o.c. along or Duro-Tuff (min. 60 mil) induction welded to -112.5 0.105 in. , 36 ksi steel purlins spaced max. 48-inch o.c, ( ) p p preliminarily fastened with Trufast PVC IW Plate purlins 48-inch o.c. Trufast PVC IW Plates with Trufast Induction Welding Tool and Magnets Existing standing seam or lap seam metal roof covers One or more layers, any Trufast #12 Purlin Fastener 6-inch o.c. along Duro-Last (min. 40 mil) or Duro-Tuff (min. 50 mil) R-77. having min. 16 gauge (0.0598 inch), 50 ksi or min. 12 gauge combination, with Trufast PVC IW Plate purlins 36-inch o.c. induction welded to Trufast PVC IW Plates with -112.5 (0.105 in.), 36 ksi steel purlins spaced max. 36-inch o.c. preliminarily fastened Trufast Induction Welding Tool and Magnets Existing standing seam or lap seam metal roof covers One or more layers, any Duro-Last (min. 60 mil), Duro-Last EV (min. 50 mil) R-78. having min. 16 gauge (0.0598 inch), 50 ksi or min. 1Z gauge combination, Trufast #12 Purlin Fastener 6-inch o.c. along or Duro-Tuff (min. 60 mil) induction welded to -150.0 0.105 in. , 36 ksi steel purlins spaced max. 36-inch o.c. ( ) p p preliminarily fastened with Trufast PVC IW Plate purlins 36-inch o.c. Trufast PVC IW Plates with Trufast Induction Welding Tool and Magnets NEMO ETC, LLC Evaluation Report D9750.05.08-R10 for FL3559-1133 Certificate of Authorization #32455 VH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 42 of 44 ONEMOjetc. RECOVERTABLE 7C: OVER STEEL SUBSTRATE ATTACHEDSYSTEM TYPE D-1: PRELIMINARILY ATTACHED INSULATION, MECHANICALLY ROOF COVER (All areas where the existing metal panels do not lay flush on the underlying purlin shall have a 0.25-1 nch-dia meter pilot hole pre -drilled into the panel prior to driving the Purlin Fastener into the purlin.) Insulation (Note 14) Roof Cover System Substrate MDP Type Attach Membrane Fasteners (Note 11) Attachment No. (Note 1) (psf) (Note 5) Standard Lao System fastened 12-inch Min. 22 ga., Type B, Grade 60 steel with One or more layers, any Duro-Tuff, Duro-Last #15 Extra Heavy Duty o.c. within 6-inch wide laps spaced R 79' existing single ply roof cover combination . Prelimattached min. 50 mil Drill Point Fastener with Duro-Last 114-inch o.c. Laps sealed with 1.5-inch 22.5 Poly -Plate heat weld. Min. 22 ga., Type B, Grade 60 steel with One or more layers, any Duro-Last, Duro-Last #15 Extra Heavy Duty Standard Lao System fastened 12-inch R-80. Prelim. attached Drill Point Fastener with Duro-Last o.c. within 3-inch wide tabs spaced 60- -30.0 existing single ply roof cover combination min. 40 mil Cleat Plates inch o.c. Min. 22 ga., Type B, Grade 60 steel with One or more layers, any Duro-Last, Duro-Last #15 Extra Heavy Duty Standard Lao System fastened 12-inch R-81. existing single ply roof cover combination Prelim. attached min. 40 mil Drill Point Fastener with Duro-Last o.c. within 6-inch wide tabs spaced -30.0 Cleat Plates 120-inch o.c. Existing standing seam or lap seam metal roof covers having min. 16 gauge (0.0598 One or more layers, any Duro-Last, Trufast #12 Purlin Fasteners with Standard Lao System fastened 9-inch R 82 inch), 50 ksi or min. 12 gauge (0.105 in.), 36 combination prelim. attached min. 40 mil Duro-Last Poly -Plate o.c. within 3-inch wide tabs spaced 60- 45.0 ksi steel purlins spaced max. 120-inch o.c. inch o.c. along purlins Min. 0.5-inch DURO- Duro-Last #14 Heavy Min. 22 ga., Type B, Grade 40 steel with GUARD EPS FAN FOLD Duty with Duro-Last 3- Duro-Last Duro-Last #15 Extra Heavy Duty Standard Lap System fastened 12-inch R-83. existing asphalt built-up roof (BUR) or 3/8-inch DURO- inch Metal Plates; 1 per min. 40 mil, Drill Point Fastener with Duro-Last O.C. within 3-inch wide tabs spaced 60- -52.5 5.3 ftz; 6 parts per 4x8 ft Poly -Plate or Duro-Last Cleat Plate inch o.c. GUARD XPS FAN FOLD section Min. 0.5-inch DURO- Duro-Last #14 Heavy Standard Lap System fastened 12-inch Min. 22 ga., Type B, Grade 40 steel with GUARD EPS FAN FOLD Duty with Duro-Last 3- Duro-Tuff, Duro-Last #15 Extra Heavy Duty o.c. within 6-inch wide laps spaced 54- R-84. existing asphalt built-up roof (BUR) or 3/8-inch DURO- inch Metal Plates; 1 per min. 50 mil Drill Point Fastener with Duro-Last inch o.c. Side laps sealed with 1.5-inch -52.5 5.3 ft ; 6 parts per 4x8 ft Poly -Plate or Duro-Last Cleat Plate GUARD XPS FAN FOLD heat -weld section NEMO ETC, LLC Evaluation Report D9750.05.08-1110 for FL1559-1133 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 43 of 44 NEMO j etc. TABLE 71): RECOVER OVER ..D FIBER SUBSTRATE ATTACHEDSYSTEM TYPE E-1: NON -INSULATED, MECHANICALLY ROOF COVER Roof Cover System Substrate (Note 1) MDP Fasteners (Note 11) No. Membrane Attach (psf) Type ENERFOAM Installation Min. 2-inch Tectum I Through -fastened 6-inch o.c. in rows 48-inch o.c. R-85. with existing single Duro-Last, Duro-Last Auger Fastener (min. 2- N/A -30.0 Fastener rows sealed with 10-inch wide strip of Duro- ply roof cover min. 4 min. 0-mil inch embedment) Last, with a 1.5-inch heat weld on all sides Min. 3-inch Tectum I Duro-Last Auger Fastener (min. 2- 7/16-inch diameter x 2.5-inch deep pilot holt filled with Through -fastened 6-inch o.c. in rows 96-inch o.c. R-86. with existing single Duro-Last, inch embedment) with 2" Auger Dupont ENERFOAM followed by fastener installation Fastener rows sealed with 10-inch wide strip of Duro- -67.5 ply roof cover min. 40-mil Plate and Dupont ENERFOAM' within 20-40 seconds after dispensing the foam Last, with a 1.5-inch heat weld on all sides System No. I Substrate (Notes 1 & 12) Primer / Treatment Roof Cover (Note 16) MDP (psf) Existing asphaltic roof system with mechanically fastened and/or adhered Duro-Fleece or Duro-Fleece Plus / Duro-Fleece CR-20 (splatter R-87. underlying components (insulation, coverboard or base sheet) and with existing None applied) -150.0 granule -surface BUR or granule -surface 5B5 or APP modified bitumen cap sheet Existing asphaltic roof system with adhered underlying components (insulation, R-88. coverboard or base sheet) over monolithic deck and with existing smooth- or None aDuro-Fleece or Duro-Fleece Plus /Duro-Fleece CR-20 (splatter applied) -370.0 granule -surface BUR or granule -surface SBS or APP modified bitumen cap sheet applie NEMO ETC, LLC Evaluation Report D9750.05.08-1110 for FL1559-1113 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 10: 10/17/2019 ©2019 NEMO ETC, LLC Duro-Last Single Ply Roof Systems; (800) 248-0280 Appendix 1, Page 44 of 44