HomeMy WebLinkAboutInterior Lightning Compliance Certificate6 COMcheck Software Version 4.1.1.0
�( Interior Lighting Compliance Certificate
Project Information
Energy Code:
Project Title:
Project Type:
Construction Site:
INDRIO RD & KING HWY
FORT PIERCE, FL
2017 Florida Building Code, Energy Conservation
21910262 7 ELEVEN
New Construction
Owner/Agent:
CREIGHTON COMMERCIAL
DEVELOPMENT
900 SW PINE ISLAND ROAD, SUITE
202
CAPE CORAL, FL 33991
239-210-0455
mross@creightondev.com
Designer/Contractor:
CUHACI & PETERSON
1925 Prospect Avenue
Orlando, FL 32814
407-661-9100
Additional Efficiency Package(s)
Reduced interior lighting power. Requirements are implicitly enforced within interior lighting allowance calculations.
Allowed Interior Lighting Power
A
Area Category
B C D
Floor Area Allowed Allowed Watts
(ft2) Watts / ft2 (B X C)
1-Retail 3454 . 1.13 3917
Total Allowed Watts = 3917
Proposed Interior Lighting Power
A B C D E
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D)
Fixture Fixtures Watt.
1-Retail
LED 1: A2: Other:
LED 2: A2E: Other:
LED 3: C: LED Linear 33W:
LED 4: DP4: Other:
LED 6: DP8: Other:
LED 5: DP8E: Other:
LED 7: DP4E: Other:
LED 10: H: Other:
Interior Lighting PASSES: Design 38% better than code
Interior Lighting Compliance Statement
1 25
40
1000
1 5
40
200
1 1
32
32
1 6
38
228
1 8
70
560
1 1
70
70
1 4
33
132
1 6
32
192
Total Proposed Watts = 2414
Compliance Statement. The proposed interior lighting design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been
designed to meet the 2017 Florida Building Code, Energy Conservation requirements in COMcheck Version 4.1.1.0 and to comply
with any applicable mandatory requirements listed in the InspectioritChegJklist.
Juan Marcos Lujambio - Engineering Designer II 03 b5 CIL>20
Name - Title Signature Date
Project Title: 21910262 7 ELEVEN Report date: 03/05/20
Data filename: W:\2019\2190262\Deliverables\Plot files\2020-03-05_Permit Set\Comcheck\2191075 MIAMI Page 1 of 8
GARDENS FL Energy Compliance.cck
6�(
COMcheck Software Version 4.1.1.0
Exterior Lighting Compliance Certificate
Project Information
Energy Code:
Project Title:
Project Type:
Exterior Lighting Zone
Construction Site:
INDRIO RD & KING HWY
FORT PIERCE, FL
Allowed Exterior Lighting Power
A
Area/Surface Category
2017 Florida Building Code, Energy Conservation
21910262 7 ELEVEN
New Construction
2 (Neighborhood business district)
Owner/Agent:
CREIGHTON COMMERCIAL
DEVELOPMENT
900 SW PINE ISLAND ROAD, SUITE
202
CAPE CORAL, FL 33991
239-210-0455
mross@creightondev.com
B
Quantity
Designer/Contractor:
CUHACI & PETERSON
1925 Prospect Avenue
Orlando, FL 32814
407-661-9100
C D E
Allowed Tradable Allowed Watts
Watts / Unit Wattage (B X C)
Main entry 6 ft of door
20 Yes
120
Other door (not main entry) 3 ft of door
20 Yes
60
Total Tradable Watts (a) =
180
Total Allowed Watts =
180
Total Allowed Supplemental Watts (b) =
600
(a) Wattage tradeoffs are only allowed between tradable areas/surfaces.
(b) A supplemental allowance equal to 600 watts may be applied toward compliance of both
non -tradable and tradable areas/surfaces.
Proposed Exterior Lighting Power
A
B C D
E
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast
Lamps/ # of Fixture
(C X D)
Fixture Fixtures Watt.
Main entry (6 ft of door width): Tradable Wattage
LED 11: J: Other:
1 4 31
124
LED 12: N: Other:
1 2 24
48
Other door (not main entry) (3 ft of door width): Tradable Wattage
LED 10: G2: Other:
1 9 31
279
Total Tradable Proposed Watts =
451
Exterior Lighting Compliance Statement
Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application. The proposed exterior lighting systems have been
designed to meet the 2017 Florida Building Code, Energy Conservation requirements in COMcheck Version 4.1.1.0 and to comply
with any applicable mandatory requirements listed in the Inspecti cklist. �1
Juan Marcos Lujambio - Engineering Designer II Ii75 60Z0
Name - Title Signature Date
Project Title: 21910262 7 ELEVEN Report date: 03/05/20
Data filename: W:\2019\2190262\Deliverables\Plot files\2020-03-05_Permit Set\Comcheck\2191075 MIAMI Page 2 of 8
GARDENS FL Energy Compliance.cck
COMcheck Software Version 4.1.1.0
Inspection Checklist
Energy Code: 2017 Florida Building Code, Energy Conservation
Requirements: 97.0% were addressed directly in the COMcheck software
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section
#
Plan Review
mplies?
F-C
Comments/Assumptions
& Req.ID
C405.6
Plans, specifications, and/or
❑Complies
Requirement will be met.
[PR17]1
calculations provide all information
❑Does Not
with which compliance can be
❑Not Observable
determined for the electrical systems
❑Not Applicable
and equipment and document where
exceptions are claimed. Provisions are
made for metering individual tenant
units. Feeder connectors (for feeder
and branch circuits) sized in
accordance with approved plans with
maximum drop of 5% voltage drop
total.
C103.2
Plans, specifications, and/or
❑Complies
Requirement will be met.
[PR4]1
calculations provide all information
❑Does Not
with which compliance can be
❑Not Observable
determined for the interior lighting
❑Not'Applicable
and electrical systems and equipment
and document where exceptions to
the standard are claimed. Information
provided should include interior
lighting power calculations, wattage of
bulbs and ballasts, transformers and
control devices.
C103.2
Plans, specifications, and/or
❑Complies
Requirement will be met.
[PR8]1
calculations provide all information
❑Does Not
with which compliance can be
❑Not Observable
determined for the exterior lighting
❑Not Applicable
and electrical systems and equipment
and document where exceptions to
the standard are claimed. Information
provided should include exterior
lighting power calculations, wattage of
bulbs and ballasts, transformers and
control devices.
C406
Plans, specifications, and/or
❑Complies
Requirement will be met.
[PR9]1
calculations provide all information
❑Does Not
with which compliance can be
determined for the additional energy
❑Not Observable
efficiency package options.
❑Not Applicable
Additional Comments/Assumptions:
1 I High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: 21910262 7 ELEVEN Report date: 03/05/20
Data filename: W:\2019\2190262\Deliverables\Plot files\2020-03-05_Permit Set\Comcheck\2191075 MIAMI Page 3 of 8
GARDENS FL Energy Compliance.cck
Section
# Footing / Foundation Inspection Complies? Comments/Assumptions
& Req.ID
C402'.2.6 Radiant heating systems panels ❑Complies Requirement will be met.
[FO12]3 insulated to >=R-3.5 on face opposite ❑Does Not
space being heated. ❑Not Observable See the Envelope Assemblies table for values.
❑Not Applicable
Additional Comments/Assumptions:
111 High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3)
Project Title: 21910262 7 ELEVEN Report date: 03/05/20
Data filename: W:\2019\2190262\Deliverables\Plot files\2020-03-05_Permit Set\Comcheck\2191075 MIAMI Page 4 of 8
GARDENS FL Energy Compliance.cck
section
#
Rough -In Electrical Inspection
Complies?
Comments/Assumptions
& Recl.ID
C405.2.1
Lighting controls installed to uniformly
❑Complies
Requirement will be met.
[EL15]1
reduce the lighting load by at least
[]Does Not
50%.
❑Not Observable
❑Not Applicable
C405.2.1
Occupancy sensors installed in
❑Complies
Requirement will be met.
[EL18]1
required spaces.
❑Does Not
❑Not Observable
❑Not Applicable
C405.2.1,
Independent lighting controls installed
❑Complies
Requirement will be met.
C405.2.2.
per approved lighting plans and all
[]Does Not
3
manual controls readily accessible and
❑Not Observable
[EL23]2
visible to occupants.
❑Not Applicable
C405.2.2.
I Automatic controls to shut off all
❑Complies
Requirement will be met.
1
building lighting installed in all
❑Does Not
[EL22]2
buildings.
❑Not Observable
❑Not Applicable
C405.2.3
Daylight zones provided with
❑Complies
Requirement will be met.
[EL16]2
individual controls that control the
❑Does Not
lights independent of general area
❑Not Observable
lighting.
❑Not Applicable
C405.2.3,
Primary sidelighted areas are
❑Complies
Exception: Requirement does not apply.
C405.2.3.
equipped with required lighting
❑Does Not
1,
C405.2.3.
controls.
❑ Not Observable
2
❑Not Applicable
[EL20]1
C405.2.3,
Enclosed spaces with daylight area
❑Complies
Exception: Requirement does not apply.
C405.2.3.
under skylights and rooftop monitors
❑Does Not
1,
are equipped with required lighting
❑Not Observable
C405.2.3.
3
controls.
❑Not Applicable
[EL21]1
C405.2.4
Separate lighting control devices for
❑Complies
Requirement will be met.
[EL4]1
specific uses installed per approved
❑Does Not
lighting plans.
❑Not Observable
❑Not Applicable
C405.2.4
Additional interior lighting power
❑Complies
Requirement will be met.
[EL8]1
allowed for special functions per the
❑Does Not
approved lighting plans and is
❑Not Observable
automatically controlled and ,
separated from general lighting.
❑Not Applicable
C405.2.5
Automatic lighting controls for exterior
❑Complies
Requirement will be met.
[EL25]na0
lighting installed. Controls will be
❑Does Not
daylight controlled, set based on
❑Not Observable
business operation time -of -day, or
❑Not Applicable
reduce connected lighting > 30%
C405.3
Exit signs do not exceed 5 watts per
❑Complies
Requirement will be met.
[EL6]1
face.
❑Does Not
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
111 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3)
Project Title: 21910262 7 ELEVEN Report date: 03/05/20
Data filename: W:\2019\2190262\Deliverables\Plot files\2020-03-05_Permit Set\Comcheck\2191075 MIAMI Page 5 of 8
GARDENS FL Energy Compliance.cck
111 High Impact (Tier 1) 1 2 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3)
Project Title: 21910262 7 ELEVEN Report date: 03/05/20
Data filename: W:\2019\2190262\Deliverables\Plot files\2020-03-05_Permit Set\Comcheck\2191075 MIAMI Page 6 of 8
GARDENS FL Energy Compliance.cck
Section
#
Final Inspection
Complies?
Comments/Assumptions
& Req.ID
C303.3,
Furnished 0&M instructions for
❑Complies
Requirement will be met.
�C408.2.5.
systems and equipment to the
❑Does Not
2
building owner or designated
❑Not Observable
�[FI17]3
representative.
❑Not Applicable
C405.4.1
Interior installed lamp and fixture
❑Complies
See the Interior Lighting fixture schedule for values.
[FI18]1
lighting power is consistent with what
[]Does Not
is shown on the approved lighting
❑Not Observable
plans, demonstrating proposed watts
❑Not Applicable
are less than or equal to allowed
watts.
C405.5.1
Exterior lighting power is consistent
❑Complies
See the Exterior Lighting fixture schedule for values.
[FI19]1
with what is shown on the approved
❑Does Not
lighting plans, demonstrating
❑Not Observable
proposed watts are less than or equal
❑Not Applicable
to allowed watts.
C408.2.5.
Furnished as -built drawings for
❑Complies
Requirement will be met.
1
electric power systems within 90 days
❑Does Not
[F[16]3
of system acceptance.
❑Not Observable
❑Not Applicable
C408.3
Lighting systems have been tested to
❑Complies
Requirement will be met.
[F133]1
ensure proper calibration, adjustment,
❑Does Not
programming, and operation.
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
111 High Impact (Tier 1) 1 2 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3)
Project Title: 21910262 7 ELEVEN Report date: 03/05/20
Data filename: W:\2019\2190262\Deliverables\Plot files\2020-03-05_Permit Set\Comcheck\2191075 MIAMI Page 7 of 8
GARDENS FL Energy Compliance.cck
Project Title: 21910262 7 ELEVEN Report date: 03/05/20
Data filename: W:\2019\2190262\Deliverables\Plot files\2020-03-05_Permit Set\Comcheck\2191075 MIAMI Page 8 of 8
GARDENS FL Energy Compliance.cck