HomeMy WebLinkAboutProduct Approval Affidavit�� Ql tl F S.T
.. _ t'
City of Port Saint Lucie Building Department Product Approval Submittal Affidavit"
Permit # Building Address: Contractor:
INDRIO RD
& KINGS HWY CREIGHTON COMPANIES, LLC
FL # or
Miami -Dade
Product
Model #
Manufacturer
Glass
Description
Attachment Method Type, Size,
Spacing & Embedment
Building Design
Pressure
Product Design
Pressure
FL8787.2 R-9
STOREFRONT
IR501
KAWNEER
INSULATED
4 ANCHORS PER MULLION
+35.7 PSF/
+65 PSF /
IMPACT RATED
* WOOD: No.12 SMS SCR 1-1/4" EMBED
-47.8 PSF
-65 PSF
LOW E
STEEL: 1/4-20 SELF TAP SCR FULL EMBED
CONC: 1/4" TAPCON 1-1/2" EMBED
FL8786.3 R-9
STOREFRONT
350
KAWNEER
IMPACT RATED
NA ATTACH TO FRAME ABOVE
+35.7 PSF/
+65 PSF /
DOOR
LOW E
-47.8 PSF
-65 PSF
FL1559.1 R-3
SINGLE PLY
SYSTEM #
DURO-LAST
NA
INSUL/CB: #12 DP W/ 3" WAFFLE
-90.1 PSF
-97 PSF
MEMBRANE
S-38
HEAD PLATE AT 12'�0.C. EA. WAY
(UPLIFT)
(UPLIFT)
ROOFING
MEMBRANE: #12 DP W/ 3" WAFFLE
HEAD PLATE AT 48" @SEAM
MIN. OR PER MANUF'R REQ'MTS
No.18-828.09
ALUMINUM
NA
F&L
NA
1/2" DIA. THRU-BOLTS MIN.
-35.7 PSF
-51 PSF
EQUIPMENT
ALUMINUM
2 PER LEG, SEE
(ZONE 1
(UPLIFT) ALL
STAND
PARTS INC.
STRUCTURAL DWGS
UPLIFT)
UNITS ARE IN
ZONE 1
FL8394.3 R-5
HOLLOW
707
CURRIES
NA
3 MASONRY ANCHORS PER JAMB
+35.7 PSF/
+80 PSF / ..
METAL DOOR
DIVISION OF
-47.8 PSF
-80 PSF
AND FRAME
AADG, INC.
No.19-0516.08
LOUVER
ESD-635DE
GREENHECK
NA
1/4" TAPCON 6" O.C. MAX.
+35.7 PSF/
+150 PSF /
2-1/2" MIN. EMBED
-47.8 PSF
-150 PSF
I have reviewed the above components or cladding and i have approved their
use in this structure. These products proviFv
dequate resistance to the wind
loads and forces specified by current cade isions.
11 .. �� A. �F FI,On
Name: _
Signature:
Certification Nu
Date:
o'f REY SUCH,
�•._ AR97833
Products itemized above have been selected by design professional as
appropriate for this project. If the General Contractor obtains approval to
substitute alterante products, it is his responsibility to provide appropriate
documentation to the authority having jurisdiction. Such procedures will be at
no additional cost to Owner.
* Secure 1" (nominal) or 2" (nominal) wood bucking to steel or concrete
with 0.157" PA Fasteners at 18" O.C. maximum.