HomeMy WebLinkAboutProduct Summary; CurriesCURRIES Product Summary General Information 1) Product is qualified for Large and Small Missile Impact unless noted. 2) Not approved for Water Infiltration unless noted. 3) Product meets the requirements of the High Velocity Hurricane Zone. 4) Substitution of hardware components must be in compliance with the Florida Building Code. Hardware Assembly Rating Size Door Door Hardware Notes Ref. PSF Opening Series Face Sargent 10 Line or 6500 Series A 50 8'0" x 8'0" 707 Louver Cylindrical w/ Sargent 480 Series Anemostat FPL2 Dead Bolt, and Ives 360 (12") Louver per Leaf surface bolts on each leaf B 57.2 4'0" x 7'0" 747 Flush Sargent HC8800 Rim Exit Sargent 8200 Mortise w/ Deadbolt 12 Ga Min x 16" C 60 6'0" x 7'0" 707 Flush and Ives'360 (12") Surface Bolts Head Reinf. For .on inactive leaf Surface Bolt 1 anchor per leaf D 62 8'0" x 8'0" 747 Flush HC8700 Exit Device on both leafs in head @ 16" from center 1�2 Sargent 8200 Mortise, or Sargent 12" x 12" min E 72 TO" x TO" 707 Glass 10 Line Cylindrical, or Schlage D window, 24" x 32" Series Cylindrical max window F 80 3'0" x 7'0" 707 Flush Sargent 8900 Mortise Exit Device 7 Ga Strike Reinforcement G 85 3'0" x 7'0" 707 Flush Sargent 6500 Cylindrical Lock H 100 3'0" x 7'0" 707 Flush Sargent 8200 Mortise w/ Deadbolt 7 Ga Strike Reinforcement Doors 1) Curries Embossed or CURRIStain doors may be used when a 707 is listed. 2) Curries single doors as shown in the drawings are qualified as Outswing only. 3) Minimum 18 gauge (0.041 ") Cold rolled, Galvanized, or Stainless Steel doors unless noted. 4) Minimum 16 gauge (0.053") end channels unless noted. 5) Minimum 14 gauge (0.073") lock channel and hinge channel unless noted. Frames 1) KID mitered or welded three -sided door frames may be used. 2) Minimum 16 gauge (0.053"min) frames unless noted. 3) Frame jamb depth 5-3/4" min, 14" max unless noted. 4) Face dimensions of 2" on jambs. Heads with 2" min - 4" max face unless noted. 5) Minimum 7 gauge (0.171") hinge reinforcement unless noted. Thresholds and Weather-strip 1) Thresholds McKinney Products Part Nos. MCK177, MCK181, MCK2005; National Guard Part Nos. 803, 804, 896, 8315; Pemko Part Nos. 177, 181, 20 2) Weather-strips MCKS88, MCK303 (Use MCK303 with continuous hinges) National Guard Part Nos. 160, 5050 (Use 160 with continuous hinges) Pemko Part Nos. S88, 303 (Use 303 with continuous hinges) RD0445rl 1 of 5 10/29/2012 For use with FL8394 Tested Protocols Used 1) TAS 201-94, Impact Test Procedures 2) TAS 202-94, Criteria for Testing Impact and Non -Impact Resistant Building Envelope Components Using Uniform Static Air Pressure. 3) TAS 203-94, Criteria For Testing Products Subject to Cyclic Wind Pressure Loading. Assembly A I i MAX 96" MAX ACTIVE LEAF e LOUVER LOUVER 31-3/4'_� MAX 48' MAX —i 48" MAX----{ EXTERIOR ELEVATION loo" MAX 96" MAX 73-1/4" MAX Assembly B 1) Curries Model 747 Flush door, 16 gauge (0.053") minimum. 2) Hinge channel to be 12 gauge (0.110") minimum. 3) Ribs to be 20 gauge (0.032") minimum. 4) Rim Exit Strike reinforcement 12 gauge (0.110") minimum. 1) Head Reinforcement required for surface bolt, Minimum 12 gauge (0.105") x 16". 2) Surround Channel required, Minimum 14 gauge (0.073"). 3) Door Surface Bolt Reinforcement required, Minimum 12 gauge (0.105"). 4) Product does not meet "Large Missile Impact". 5) Curries Model 707 door, 16 gauge (0.053") minimum. 6) Latch Bolt and Dead Bolt required I--- 5 2 " MAX--+ 88' MAX RD0445r1 2 of 5 For use with FL8394 10/29/2012 c Assembly C 76' MAX �72' MAX 84' MAX 8£ MF �36' MAX-36' MAX-{ EXTERIOR ELEVATION X AssemblyD 1) Curries Model 747 Flush door, 16 gauge (0.053") minimum. 2) Head Reinforcement required, Minimum 12 gauge (0.105") x 16". 3) One anchor in the frame head per door leaf, 16" from center on pairs, 14" from the lock centerline on singles. RD0445rl 10/29/2012 1) Head Reinforcement required for surface bolt, Minimum 12 gauge (0.105") x 16". 2) Door Surface Bolt Reinforcement required, Minimum 12 gauge (0.105"). 3) Curries Model 707 Flush door, 16 gauge (0.053") minimum 100' MAX. i 100' MAX 1 48' MAX f 48" MAX j EXTERIOR ELEVATION 3 of 5 For use with FL8394 Assembly E r,-3 40" MAX 6" MAX �:4 84„ MAX :: EXTERIOR ELEVATION Assembly F 1) Weld perimeter of end channels together on corners of door. 2) Minimum 7 gauge (0.171 ") frame strike reinforcement. 3) Mortise Lock Reinforcement 14 gauge minimum (0.073") x 1813 . 4) Mortise reinforcement hinge side 14 gauge minimum (0.073") x 1299 . 5) Curries Model 707 Flush door, 18 gauge (0.041 ") minimum. 1) Minimum 12" x 12" window, Maximum 24" x 32" (768 sq in) window. 2) Curries Type 1, Type 2, or Type 3 vision light kit, 18 gauge (0.041 ") minimum. 3) Door surround channel minimum 20 gauge (0.032"). 4) Curries Model 707 door, 18 gauge (0.041 ") minimum. 40" MAX F36" MAX---�] EXTERIOR ELEVATION RD0445rl 4 of 5 For use with FL8394 10/29/2012 --" Assembly G --- 4, 0 " MAX --I 88" MAX X EXTERIOR ELEVATION Assembly # H 1) Weld perimeter of end channels together on corners of door. 2) Curries Model 707 Flush door, 18 gauge (0.041 ") minimum. RD0445r1 10/29/2012 5 of 5 1) Weld perimeter of end channels together on corners of door. 2) Curries Model 707 Flush door, 18 gauge (0.041 ") minimum. --- 4 0" M A X— -1 11 88, MAX X EXTERIOR ELEVATION For use with FL8394