HomeMy WebLinkAboutProduct Summary; CurriesCURRIES
Product Summary
General Information
1) Product is qualified for Large and Small Missile Impact unless noted.
2) Not approved for Water Infiltration unless noted.
3) Product meets the requirements of the High Velocity Hurricane Zone.
4) Substitution of hardware components must be in compliance with the Florida Building
Code.
Hardware
Assembly
Rating
Size
Door
Door
Hardware
Notes
Ref.
PSF
Opening
Series
Face
Sargent 10 Line or 6500 Series
A
50
8'0" x 8'0"
707
Louver
Cylindrical w/ Sargent 480 Series
Anemostat FPL2
Dead Bolt, and Ives 360 (12")
Louver per Leaf
surface bolts on each leaf
B
57.2
4'0" x 7'0"
747
Flush
Sargent HC8800 Rim Exit
Sargent 8200 Mortise w/ Deadbolt
12 Ga Min x 16"
C
60
6'0" x 7'0"
707
Flush
and Ives'360 (12") Surface Bolts
Head Reinf. For
.on inactive leaf
Surface Bolt
1 anchor per leaf
D
62
8'0" x 8'0"
747
Flush
HC8700 Exit Device on both leafs
in head @ 16"
from center
1�2
Sargent 8200 Mortise, or Sargent
12" x 12" min
E
72
TO" x TO"
707
Glass
10 Line Cylindrical, or Schlage D
window, 24" x 32"
Series Cylindrical
max window
F
80
3'0" x 7'0"
707
Flush
Sargent 8900 Mortise Exit Device
7 Ga Strike
Reinforcement
G
85
3'0" x 7'0"
707
Flush
Sargent 6500 Cylindrical Lock
H
100
3'0" x 7'0"
707
Flush
Sargent 8200 Mortise w/ Deadbolt
7 Ga Strike
Reinforcement
Doors
1) Curries Embossed or CURRIStain doors may be used when a 707 is listed.
2) Curries single doors as shown in the drawings are qualified as Outswing only.
3) Minimum 18 gauge (0.041 ") Cold rolled, Galvanized, or Stainless Steel doors unless noted.
4) Minimum 16 gauge (0.053") end channels unless noted.
5) Minimum 14 gauge (0.073") lock channel and hinge channel unless noted.
Frames
1) KID mitered or welded three -sided door frames may be used.
2) Minimum 16 gauge (0.053"min) frames unless noted.
3) Frame jamb depth 5-3/4" min, 14" max unless noted.
4) Face dimensions of 2" on jambs. Heads with 2" min - 4" max face unless noted.
5) Minimum 7 gauge (0.171") hinge reinforcement unless noted.
Thresholds and Weather-strip
1) Thresholds
McKinney Products Part Nos. MCK177, MCK181, MCK2005;
National Guard Part Nos. 803, 804, 896, 8315; Pemko Part Nos. 177, 181, 20
2) Weather-strips
MCKS88, MCK303 (Use MCK303 with continuous hinges)
National Guard Part Nos. 160, 5050 (Use 160 with continuous hinges)
Pemko Part Nos. S88, 303 (Use 303 with continuous hinges)
RD0445rl 1 of 5
10/29/2012
For use with FL8394
Tested Protocols Used
1) TAS 201-94, Impact Test Procedures
2) TAS 202-94, Criteria for Testing Impact and Non -Impact Resistant Building Envelope
Components Using Uniform Static Air Pressure.
3) TAS 203-94, Criteria For Testing Products Subject to Cyclic Wind Pressure Loading.
Assembly A
I i MAX
96" MAX
ACTIVE
LEAF e
LOUVER LOUVER
31-3/4'_�
MAX
48' MAX —i 48" MAX----{
EXTERIOR ELEVATION
loo"
MAX
96"
MAX
73-1/4"
MAX
Assembly B
1) Curries Model 747 Flush door, 16
gauge (0.053") minimum.
2) Hinge channel to be 12 gauge
(0.110") minimum.
3) Ribs to be 20 gauge (0.032")
minimum.
4) Rim Exit Strike reinforcement 12
gauge (0.110") minimum.
1) Head Reinforcement required for
surface bolt, Minimum 12 gauge
(0.105") x 16".
2) Surround Channel required, Minimum
14 gauge (0.073").
3) Door Surface Bolt Reinforcement
required, Minimum 12 gauge (0.105").
4) Product does not meet "Large Missile
Impact".
5) Curries Model 707 door, 16 gauge
(0.053") minimum.
6) Latch Bolt and Dead Bolt required
I--- 5 2 " MAX--+
88'
MAX
RD0445r1 2 of 5 For use with FL8394
10/29/2012
c
Assembly C
76' MAX
�72' MAX
84'
MAX
8£
MF
�36' MAX-36' MAX-{
EXTERIOR ELEVATION
X
AssemblyD
1) Curries Model 747 Flush door, 16 gauge
(0.053") minimum.
2) Head Reinforcement required,
Minimum 12 gauge (0.105") x 16".
3) One anchor in the frame head per door
leaf, 16" from center on pairs, 14" from
the lock centerline on singles.
RD0445rl
10/29/2012
1) Head Reinforcement required for
surface bolt, Minimum 12 gauge
(0.105") x 16".
2) Door Surface Bolt Reinforcement
required, Minimum 12 gauge
(0.105").
3) Curries Model 707 Flush door, 16
gauge (0.053") minimum
100' MAX. i
100'
MAX
1 48' MAX f 48" MAX j
EXTERIOR ELEVATION
3 of 5 For use with FL8394
Assembly E
r,-3
40" MAX
6" MAX
�:4
84„
MAX
::
EXTERIOR ELEVATION
Assembly F
1) Weld perimeter of end channels
together on corners of door.
2) Minimum 7 gauge (0.171 ") frame
strike reinforcement.
3) Mortise Lock Reinforcement 14
gauge minimum (0.073") x 1813
.
4) Mortise reinforcement hinge side 14
gauge minimum (0.073") x 1299
.
5) Curries Model 707 Flush door, 18
gauge (0.041 ") minimum.
1) Minimum 12" x 12" window,
Maximum 24" x 32" (768 sq in)
window.
2) Curries Type 1, Type 2, or Type 3
vision light kit, 18 gauge (0.041 ")
minimum.
3) Door surround channel minimum 20
gauge (0.032").
4) Curries Model 707 door, 18 gauge
(0.041 ") minimum.
40" MAX
F36" MAX---�]
EXTERIOR ELEVATION
RD0445rl 4 of 5 For use with FL8394
10/29/2012
--"
Assembly G
--- 4, 0 " MAX --I
88"
MAX
X
EXTERIOR ELEVATION
Assembly # H
1) Weld perimeter of end channels
together on corners of door.
2) Curries Model 707 Flush door, 18
gauge (0.041 ") minimum.
RD0445r1
10/29/2012
5 of 5
1) Weld perimeter of end channels
together on corners of door.
2) Curries Model 707 Flush door, 18
gauge (0.041 ") minimum.
--- 4 0" M A X— -1
11
88,
MAX
X
EXTERIOR ELEVATION
For use with FL8394