FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: BRENDA HOLLAND Builder Name:
Street: -469 SE NARANJA AVENUE Permit Office:
City,State,Zip: PORT ST.LUCIE,FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL,Fort.Pierce County:: ST,LUCIE COUNTY(Florida Climate Zone 2)
1. New construction or existing Addition 9. Wall Types(1980.0 sgft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 1980.00 ftz
b.NIA R= ftz
3. Number of units,if multiple family 1 e.NIA R= ftz
4. Number of Bedrooms(Bedrms In Addition) 4(1) d.N/A R= ftz
5. Is this a worst case? No 10.Ceiling Types (1823.0 sgft:) Insulation Area a.Under Attic(Vented) r;< R=30.0 1823.00 ftz
6. Conditioned floor area above grade(ftz) 1823 b.N/A R= ftz
Conditioned floor area below grade(ftz) 0 c.WA R= ftz:,..:
11.Ducts R ftz
7. Windows(260.1 sgft.) Description Area a.Sup:Attic,Ret:Attic,AH:FOYER. 6 325
a. U-Factor. Dbl,U=0.65 260.08 ftz
SHGC: SHGC=0:25
b. U-Factor. N/A ftz 12.Cooling systems kBtulhr. Efficiency
SHGC: a.Central Unit 41.0, SEER:15.00
c. U-Factor: NIA ftz
SHGC: 13.Heating systems kStu/hr Efficiency
d. U-Factor. NIA ftz a.Electric Strip.Heat 27.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 2.000 ft.
Area Weighted Average SHGC: 0.250 14.Hot water systems-None required
a. Cap:NIA
8. Floor Types (1823.0 sgft,) „_; Insulation Area EF:0.000
a.Slab-On-Grade Edge Insulation R=0.0 1823.00 ftz b. Conservation features
b.N/A ; R= ftz
c.WA R= ftz 15.Credits CF,Pstat
Glass/Floor Area: 0.143 Total Proposed Modified Loads: 62.93 PAS
Total Baseline Loads: 64,15 �77�7
1 hereby certify that the plans and specifications covered by Review of the plans and
0 0.
this calculation are in compliance with the Florida Energy specifications covered by this �tis,;;�r,,.""
Code. calculation indicates compliance r �jk'A�i,, o�
r with the Florida Energy Code. Y =' 4
PREPARE[ BY: _ _ __ _ _-__ Before construction is completed z �yA
this building will be inspected for !,
DATE: !`{- �� - t;
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance Florida Statutes.
with the Florida Energy Code. G-OU
OWNER/AGENT: BUILDING OFFICIAL:
DATE: _ _-. DATE:
- Compliance requires'certification by the air handier unit manufacturer that the air handier enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
1/11/2017 12:10 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index, the more efficient the home.
469 SE NARANJA AVENUE, PORT ST. LUCIE, FL,
1. New construction or existing Addition 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 1980.00.ft2
3. Number of units,if multiple family b.N/A R= ft2
1 c.N/A R= ft2
4. Number of Bedrooms 4(1) d.NIA R= ft2
5. Is this a worst case? No 10.Ceiling Types Insulation - Area
a.Under Attic(Vented) R=30.0 1823.00 ft2
6. Conditioned floor area(ft2) 1823 b.NIA R= ft2
7. Windows" Description Area c.NIA R= ft2
a. U-Factor: Dbl,U=0.65 260.08 ft2 11,Ducts R ft2
SHGC: SHGC=0.25 a.Sup:Attic,Ret:Attic,AH:.FOYER 6' -325
b. U-Factor. N/A ft2
SHGC: 12.Cooling systems kBtu/hr Efficiency
c. U-Factor. N/A ft2 a.Central Unit 41.0 SEER:15.00
SHGC:
d. U-Factor: NIA ft2 13.Heating systems SHGC: 9 Y kBtu/hr Efficiency
Area Weighted Average Overhang a.Electric Strip Heat 27.0 COP:1.00 Depth: 2.000 ft. -
Area Weighted Average SHGC: 0.250
8. Floor Types Insulation Area 14.Hot water systems-None required
a.Slab-On-Grade Edge Insulation R=0.0 1823.00 ft2 a• Cap:NIA EF:
b.N/A R= ft2
c.N/A R= ft2 b. Conservation features
15.Credits CF,Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
/ �HGS7A?�
Construction through the ai�ove energy saving features which will be installed (or exceeded) eN os�;.��,,-,�o
in this home before final inspection. Otherwise, a new EPL Display Card will be completed ,A
based on installed Code compliant features.
Builder Signature: = :"C.
9 Date: o� r.,<,,�.
Address of New Home: City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
*"Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
1/11/2017 12:10 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1
L
FORM R405-2014
FLOORS"
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet _
6 Slab-On-Grade Edge Insulatio MASTER BEDRO 12 ft 0 172 ft2 0 1 0
7 Slab-On-Grade Edge Insulatio NEW CLST. 24 ft 0 70 ft2 ____ 0 1 0
8 Slab-On-Grade Edge Insulatio FOYER 8 ft 0 206 ft2 __-_ 0 1 0
9 Slab-On-Grade Edge Insulatio BEDROOM 4 32 ft 0 150 ft2 --_- 0 1 0
10SIab-On-Grade Edge Insulatio BEDROOM 3 29 ft 0 196 ft2 ___ 0 1 0
11S1ab-On-Grade Edge Insulatio LIVING loft 0 100 ft2 ---- 0 1 0
12Slab-On-Grade Edge Insulatio BATH 2 8 ft 0 64 ft2 0 1 0
ROOF
Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
# Type Materials Area Area Color Absor. Tested Tested" Insul. (deg)
1 Gable or Shed Composition shingles 1921 ft2 304 ft2 Medium 0.6 No 0.9 No 0 18.4
ATTIC
V # Type, Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 150 1823 ft2 N N
CEILING
_ # Ceiling Type _ Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) BATH 3 30 Blown 72 ft2 0.1 _ Wood
2 Under Attic(Vented) BEDROOM 2 30 Blown 210 ft2 0.1 Wood
3 Under Attic(Vented) FAMILY 30 Blown 286 ft2 0.1 Wood
4 Under Attic(Vented) KITCHEN 30 Blown 234 ft2 0.1 Wood
5 Under Attic(Vented) M BATH 30 Blown 63 ft2 0.1 Wood
6 Under Attic(Vented) MASTER BEDRO 30 Blown 172 ft2 0.1 Wood
7 Under Attic(Vented) NEW CLST. 30 Blown 70 ft2 0.1 Wood
8 Under Attic(Vented) FOYER 30 Blown 206 ft2 0.1 Wood
9 Under Attic(Vented) BEDROOM 4 30 Blown 150 ft2 0.1 Wood
10 Under Attic(Vented) BEDROOM 3 30 Blown 196 ft2 0.1 Wood
11 Under Attic(Vented) LIVING 30 Blown 100 ft2 0.1 Wood
12 Under Attic(Vented) BATH 2 30 Blown 64 ft2 0.1 Wood
WALLS
/ Adjacent Space Cavity Width Height Sheathing Framing . Solar Below
#__..Ornt._To Wall_Type- -.._ R-Value.-_ _Ft_tn—Et_-_In_--_ -Area R-Value—Fraction-_-Absor_Grade%
1 N Exterior Concrete Block-Ext Insul BATH 3 4.1 8 0 9 0 72.0 ft2 0 0 0.6 0
2 S Exterior- Concrete Block-Ext Insul BATH-3 4.1 3 0 9 0 27.0 ft2 0 0 0.6 0
3 W Exterior. Concrete Block-Ext Insul BATH 3 4.1 9 0 9 0 81.0 ft2 0 0 0.6 0
4 E Exterior Concrete Block-Ext IneEDROOM 2 4.1 2 0 9 0 18.0 ft2 0 0 0.6 0
1/11/2017 12:10 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2014
PROJECT
Title: BRENDA HOLLAND Bedrooms: 4 Address Type: Street Address
Building Type: User Conditioned Area: 1823 Lot#t
Owner: Total Stories: 1 Block/SubDivision:
#of Units: 1 Worst Case: No PlatBook:
Builder Name: Rotate Angle: 0' Street: 469 SE NARANJA AV
Permit Office: Cross Ventilation: No County: ST.LUCIE COUNTY
Jurisdiction: Whole House Fan: No City,State,Zip: PORT ST.LUCIE,
Family Type: Single-family FL,
New/Existing: Addition
Comment:
CLIMATE
/ IECC Design Temp Int Design Temp Heating Design Daily Temp
V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Fort Pierce FL VERO BEACH_MUNI 2 39 90 70 75 299 62 Low
BLOCKS
Number Name Area Volume
1 Entire House 1823 16407
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 BATH 3 72 648 No 0 1 Yes Yes Yes
2 BEDROOM 2 210 1890 No 2 1 1 Yes Yes Yes
3 FAMILY 286 2574 No 0 1 Yes Yes Yes
4 KITCHEN 234 2106 Yes 2 1 No Yes Yes
5 M BATH 63 567 No 0 1 Yes Yes Yes
6 MASTER BEDR00 112 1548 No 2 1 1 Yes Yes Yes
7 NEW CLST. 70 630 No 0 1 Yes Yes Yes
8 FOYER 205 1854 No 0 1 Yes Yes Yes
9 BEDROOM 4 150 1350 No 0 1 1 Yes Yes Yes
10 BEDROOM 3 196 1764 No 0 1 1 Yes Yes Yes
11 LIVING 100 900 No 0 1 Yes Yes Yes
12 BATH 2 64 576 No 0 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value w_Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio BATH 3 20 ft 0 72 ft? --_- 0 1 0
2 Slab-On-Grade Edge Insulatio BEDROOM 2. 31 ft 0 210 ft' ---_ 0 1 0
3 Slab-On-Grade Edge Insulatio FAMILY 39 ft 0 286 W ____ 0 1 0
4 Slab-On-Grade Edge Insulatio KITCHEN i ft 0 234 ft2 0 1 0
5 Slab-On-Grade Edge Insulatio M BATH 7 ft 0 53 ft' 0 1 0
1/111201712:10 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: BRENDA HOLLAND Builder Name:
Street: 469 SE NARANJA AVENUE Permit Office:
City,State,Zip: PORT ST.LUCIE,FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL,Fort Pierce
COMPONENT CRITERIA CHECK
Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air-permeable insulation shall not be used as a sealing material.
Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings,drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Comers and headers shall be insulated and the junction of the foundation
Walls and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors The space between window/door jambs and framing and skylights and
framing shall be sealed.
Rim joists Rim joists are insulated and include an air barrier.
Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors) of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls Where provided in lieu of floor insulation,insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be
airtight, IC rated,and sealed to the drywall.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to available
space shall extend behind piping and wiring,
Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub-floor or drywall.
Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
1/11/2017 12:11 PM EnergyGaugeQD USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1
t
FORM R405-2014
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .0004 1914.2 105.08 197.63 .2922 7
HEATING SYSTEM
V_ # System Type Subtype Efficiency _ Capacity Block,--- Ducts
1 Electric Strip Heat None COP:1 27 kBtulhr 1 sys#1
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow_ SHR Block Ducts
1 Central Unit Split SEER:15 41 kBtu/hr cfm 0.8 1 sys#1
SOLAR HOT WATER SYSTEM-
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
ft2 - - ---
DUCTS
--=Supply-- ----Return-- Air CFM 25 CFM25 HVAC#
# Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 325 ft2 Attic 105 ft2 Default Leakage FOYER (Default) (Default) 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
Cooling [ ]]Jan Feb Mar A r May X Jun rl
Jul Au [X)Se Oct ]Nov Dec
Heatin (X]Jan Feb f Xj Mar f Apr f I May 4 Jun Jul AuE ]Sep E Oct �X]Nov f X Dec
Ventin [[ ]]Jan Feb [X Mar [X A r [ Ma [ Jun Jul Aug ]Se [ Oct ki Nov [ Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 - 78 78 78 78 78 78 80 - '^80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 56 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 58 66 66
Heating(VJEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
1/11/2017 12:10 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5
FORM R405-2014
WALLS
/ Adjacent Cavity Width Height Sheathing Framing Solar Below
___V#Ornt To.___..WaII.Type __._ Space R-Value_Ft- _In-Ft.-In- _ Area.-___R_Value. Fraction.-Absor Grade%_
5 S Exterior Concrete Block-Ext InfilEDROOM 2 4.1 15 0 9 0 135.0 ft2 0 0 0.6 0
6 W Exterior Concrete Block-Ext InfiffDR00M 2 4.1 14 0 9 0 126.0 ft2 0 0 0.6 0
7 N Exterior Concrete Block-Ext Insul FAMILY 4.1 26 0 9 0 234.0 ft2 0 0 0.6 0
8 E Exterior Concrete Block-Ext InsulFAMILY 4.1 2 0 9 0 18.0 ft2 0 0 0.6 0
9 W Exterior Concrete Block-Ext Insul FAMILY 4.1 11 0 9 0 99.0 ft2 0 0 0.6 0
10 E Exterior Concrete Block-Ext InsulM BATH 4.1 1 0 9 0 9.0 ft2 0 0 0.6 0
11 S Exterior Concrete Block-Ext InsulM BATH 4.1 6 0 9 0 54.0 ft2 0 0 0.6 0
12 E Exterior Concrete Block-Ext IndUASTER BE 4.1 7 0 9. 0 63.0 ft2 0 0 0.6 0
13 S Exterior Concrete Block-Ext InsMASTER BE 4.1 2 0 9 0 18.0 ft2 0 0 0.6 0
14 W Exterior Concrete Block-Ext InsrdASTER BE 4.1 3 0 9 0 27.0 ft2 0 0 0.6 0
15 E Exterior Concrete Block-Ext InsUEW CLST. 4.1 7 0 9 0 63.0 ft2 0 0 0.6 0
16 S Exterior Concrete Block-Ext InstIEW CLST. 4.1 10 0 9 0 90.0 ft2 0 0 0.6 0
17 W Exterior Concrete Block-Ext InsNEW CLST. 4.1 7 0 9 0 63.0 ft2 0 0 0.6 0
18 S Exterior Concrete Block-Ext Insul FOYER 4.1 8 0 9 0 72.0 ft2 0 0 0.6 0
_19 E Exterior Concrete Block-Ext InEEDROOM 4 4.1 10 0 9 0 90.0 ft2 0 0 0.6 0
20 S Exterior Concrete Block-Ext InQJEDROOM 4 4.1 15 0 9 0 135.0 ft2 0 0 0.6 0
21 W Exterior Concrete Block-Ext InfiffDROOM 4 4.1 7 0 9 0 63.0 ft2 0 0 0.6 0
22 N Exterior Concrete Block-Ext InOEDROOM 3 4.1 15 0 9 0 135.0 ft2 0 0 0.6 0
�23 E Exterior Concrete Block-Ext IngffDROOM 3 4.1 14 0 9 0 126.0 ft2 0 0 0.6 0
r24 N Exterior Concrete Block-Ext Insul LIVING 4.1 10 0 9 0 90.0 ft2 0 0 0.6 0
_25 E Exterior Concrete Block-Ext Insul BATH 2 4.1 8 0 9 0 72.0 ft2 0 0 0.6 0
DOORS
# Ornt Door Type Space Storms U-Value Ft In
In Ft WidthArea
1 W Insulated BEDROOM 2 None .39 3 7 21 ft2
2 S Insulated FOYER None .39 6 6 10 41 ft2
WINDOWS
Orientation shown is the entered,Proposed orientation.
Wall - " Overhang
_ _# Ornt ID Frame_ Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 N 1' Metal Low-E Double Yes 0.65 0.25 9.5 ft2 2 ft 0 in -1 ft 4 in None None
2 S 5 Metal Low-E Double Yes 0.65 0.25 10.8 ft2 2 ft 0 in 1 ft 4 in None None
3 N 7 Metal Low-E Double Yes 0.65 0.25 91.9 ft2 2 ft 0 in 1 ft 4 in None Node
4 W 9 Metal Low-E Double Yes 0.65 0.25 20.4 ft2 2 ft 0 in 1 ft 4 in None None
5 W 9 Metal Low-E Double Yes 0.65 0.25 23.0 ft2 2 ft 0 in 1 ft 4 in None None
6 S 11 'Metal Low-E Double Yes 0.65 0.25 9.6 ft2 2 ft 0 in 1 ft 4 in None None
7 E 19 Metal Low-E Double Yes 0.65 0.25 15.0 ft2 2 ft 0 in 1 ft 4 in None None
8 S 20 Metal Low-E Double Yes 0.65 0.25 15.0 ft2 2 ft 0 in 1 ft 4 in 'None None
9 N 22 Metal Low-E Double Yes 0.65 0.25 23.0 ft2 2 ft 0 in 1 ft 4 in None None
10 E 23 Metal Low-E Double Yes 0.65 0.25 13.0 ft2 2 ft 0 in 1 ft 4 in None None
11 N 24 Metal Low-E Double Yes 0.65 0.25 23.0 ft2 2 ft 0 in 1 ft 4 in None None
12 E 25 Metal Low-E Double Yes 0.65 0.25 6.0 ft2' 2 ft 0 in 1 ft 4 in None None
1/11/2017 12:10 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5
4 -
GENERAL NOTES
vxldwl::aemnu¢iwsmon mercamivu � ® 19� I
rcv"-�a�ia¢ox>am¢sxs�.niamval�cxxmamoun� � r�amoxmv�*KmsoaemaHrff ��a
m¢.nwoam,Avdannam.w,uxnmm•¢aelroru R1 I I
ma¢mv¢!vo®t�axlmmv�lumcimamwuwamm¢mnxm. vvl�ILrX/'FAMLY
�moQ m¢i urmmr¢.m�mv¢.mamwynw�anPoman. i///«��� � I�S
_ �aar�wu@mmv.u"vxima¢enawr LNMG BEDROOM
Y{1491n"!¢¢A:MmMDitl6.¢/®I..m®®Om�l ® WYIN 1xM
...,m+ummrrsv.wxl..�wa.®nEnrw..!¢m!•. =v°=tl IZxSs�l - a
144CtiF,
llr
IWnfAm�"®MMWY�®F9M¢hsm flGalH2.t44WFm@ ®m'•!M"¢
rmCwAA3®PJfl I.tV.nf".nwl®4Av6(1W¢tl •® b -H¢mFnl snmw"p"uml".[eIIm Ya9u�lln®e.xMan m"m.itv{�sTm9lam[n"6mnmlnoNvfxlmcum8 x I 1{�.4x..�L t'^arcrmv m".YRmp¢Ho•OGmHsWc ^ , nOIUW
cycow
r
k e- m O e-•n+mu.rlc.owu mrslawo¢.•amsu � ura All � Um m
�n¢mnona•amxln•waemlman mum amr. q .
nn¢um.avmmevewr�.srlsowax vcn®umvvn az¢ rxer �_ L�A3 u°Ww•�!. ws vuifi �F¢dWfl
as"cmunu0irue .c aw�so�"wm"�"`�l�u. vuu 2a — — lay 3�' ''� S
p � N
ID{Cca m! BAnwooMz =�37W 'm
m¢nuwxx�maws¢wmwa�ammamr.mdnmrm •.v� n�aoac am �� w ¢ � v♦ZiW6 N
�m¢anumwnlvmwunlrtnMmaimmuu�wanxwcn wsu.xn"l�.r FOYER a�W1010 m
m�umvmmsn¢ao>r+.muvx.wx•1amnnm. - m ® A Qu O I LL
nnvaermnonm¢wnmmos¢ar,a3vv®+woswuemv¢m GARAGE •,��..�B�IROON3-IO''. .., vo® �� I�r �hl 1a
l.mHm¢mm�Wm.m�rnlm¢.ma�mnmW¢w�.r 4 �T
mx•mW�:
Ww�¢mnn.mmavuxu�viH < �•�, BATHR I•"��++1 O ROOM
O
v°6w�mlwra`m n+"i°xm"ww cxmmiamnwa -]fix�xl•
.. �T
BEDROOM
l4DCfM
RENOVATION REQUIREMENTS
0
'�cnermv¢nlod¢n¢mwmNflxo�nL avm •'1¢r'•nivTGYm �u V� p (' �1
inanw ao'izm�maum"ela.omsvvam as'mm¢lvvm n ® >
rmx�l+avm®emusm"ormammemlmaumwmxrlau �nveo�m �� T9 - r¢wwa•vnsum p F— a
manmmmsimnvx!lsxmammmxmmxr¢evxnra vi�e"`imami uwrw® me naxvm U �n
� !'� ¢!¢•m� PROPOSED FLOOR PLAN
rwnSCALE m
mH.mmimn¢nP¢mu!¢ - mme o mew! 114'-ItY Z Q Q
LLB'
O �~ o
U -Q, �d' iom
EUU C6
AI@�. 5�.TIOC IYPE AWhf.INi.U4B 0.6PklCn6 RW�AN!P.Aip0.� IBiN06
tffi6t0tgllY � ® ® F n
i.F PCOmmIrMm 1o.f _- w
WINDOW.SCHEDULE �'=� '"�""'"ram" ""m 8 Q z
aa�!` O wwnax saE me nm. •4n ,ter Kff OA ""^ " wdlds .J W <LL
xc�iam� .. c o>aa ffii:
m -• • •muum®.aec n Z
- 4i
F vre • • •�n+a¢dusn.nnam Q Z F-
f U—i
• • • pgp� ow
�/,i g 6 mrQ • Y• •wn mwu•x...n d Z 0 W~
_ d
mff WINDOW AND DOOR NOTES • DOOR NOTES m Q a
BLOCK-UP DOOR DETAIL—5 ;�`"® r '¢"m �Q7�. .o�. mPm. �.m¢, rW. �nnrr.,x®.Wxm¢. •
s ®` �.¢.m.�x��,®•,.®,lE,.mWlsnm,x �x�,l.o:nx«mw.�
scaFf2'mnv 5 _ ml;wnwawms..l.mr,Q!".•�!m
. . ��"'01 ° - !a""� vntlO0i9o.."•wmumm'¢w'iI�YO:i�+m�mnm�nr�ar�u�n,.¢,m.n"o.m. aw�".v„¢.¢e.�
ca•r-Hnmwammo�w¢.rss,•voa�eavm:aysuznova<v�m ,°�1OAoeoam.nH�>ws¢z
ioHn .m.wmamr.Pmw.,�! nmmer¢�n¢�¢nmva ® v¢���ro"W"n�lam.m
v.;a'n�snvau..avnm�¢anrH.m¢m .mv�warsman.u®
' mrmm wm��m�is�a,m."'P�PYQ�oam�ml"�aw°Om¢�¢nam.v"�"'v '
"m.eavmrwror.el.aam Eo mp
vvw!"uulm®weu vmmmmmrm+w�lav9® 97A6 AL v
DETAIL m miam
SCAO33/4'=v-W
OF7
FORM-R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation -Residential Performance Method-
Project Name: BRENDA HOLLAND Builder Name:
Street: 469 SE NARANJA AVENUE Permit Office:
City,State,Zip: PORT ST.LUCIE,•FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL,Fort Pierce County:: ST.LUCIE COUNTY(Florida Climate Zone 2)
1, New construction or existing Addition . 9. Wall Types(1980.0,sqft.) Insulation Area,
2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior -R=4.1 1980.00 ft2 _
b.N/A R= ft2
3. Number of units,if multiple family 1 c.N/A R= ft2.
4. Number of BedroorrigBedrms In Addition) 4(1) d.N/A R= ft2
5, is this a worst case? No ' 10.Ceiling Types (1823.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1823.00 ft2
S. Conditioned floor area above grade(ft2)' 1823 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2z
_ 11.Ducts R ft
7. Windows(260.1 sqft.) Description Area a.Sup:Attic,.Ret:Attic,AH:FOYER 6 325
a. U-Factor. Dbl,U=0.65 260.08 ft2
SHGC: SHGC=0,25 ,
b. U-Factor: N/A ft2 i2,Cooling systems kBtu/hr Efficiency,
SHGC: a.Central Unit 41.0 SEER:15.00
c. U-Factor: N/A ft2
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Strip Heat 27.0 COP:1.00
SHGC:
Area Weighted Average•Overhang Depth: 2.000 ft.
Area Weighted Average SHGC: 0.250 14.Hot water systems-None required
a. Cap:N/A
8. Floor Types (1823.0 sqft.) Insulation Area EF:0.000
a.Slab-On-Grade Edge"Insulation R=0.0 1823.00 ft2 b. Conservation features
b.N/A R= - ftz .
c.WA R= ft2 15.Credits CF,Pstat
Glass/Floor Area: 0.143 Total Proposed Modified Loads: 62.93 r�1B A ES
Total Baseline Loads: 64.15 �7
I hereby certify that'the plans and specifications covered by Review of the plans and
this calculation are in compliance with the Florida Energy specifications covered by this
Code. ti calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
PREPARE4 BY'•�`l
(� this building will,be inspected for ;-ry o�
compliance with Section 553.908
Florida Statutes:
I hereby certify,that this building;as designed,is in compliance
with the Florida Energy Code. 'k-QDCvvr,T_�f'
OWNER/AGENT: __.�_-_...___..__ BUILDING OFFICIAL: _m.^
DATE: _�.———-- ___ _ -'---— DATE: ........__.
Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as .
certified factory-seated in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and.an envelope leakage
test report in accordance with R402.4.1.2.
1/11l2017 12:10 PM EnergyGauge®USA-.FlaRes2014 Section R4015.4.1 Compliant Software' Page 1 of 5
9
FORM`R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index, the more efficient the home.
469 SE NARANJA AVENUE, PORT ST. LUCIE, FL,
1. New construction or existing Addition 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 1980.00 ft2
b.N/A R= ft2
3. Number of units,if multiple family 1 c.NIA R= ft2
d.N/A R= ft2
4. Number of Bedrooms 4(1) 10.Ceiling Types Insulation Area
5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1823.00 ft2
6. Conditioned floor area(1`12) 1823 b.N/A R= ft2
c. R= ft2
7. Windows" Description Area
a. U-Factor: Dbl,U=0.65 260.08 ft2 11,Ducts R ft2
a.Sup:Attic,Ret:Attic,AH:FOYER fi 325
SHGC: SHGC=0.25
b. U-Factor: N/A ft2
SHGC: 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: N/A ft2 a.Central Unit 41.0 SEER:15.00.
SHGC:
d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency
SHGC: I a.Electric Strip Heat 27.0 COP:1.00
Area Weighted Average Overhang Depth: 2:000 ft.
Area Weighted Average SHGC: 0.250
8. Floor Types insulation Area 14.Hot water systems-None required Cap:N/A
a.Slab-On-Grade Edge Insulation R=0.0 1823.00 ft2 a. EF:
b.N/A R= ft2 b. Conservation features
c.N/A R= ft2
15.Credits CF, Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded) f
in this home before final inspection. Otherwise, a new EPL Display Card will be completed ,J -Vic•,
based on installed Code compliant features.
Builder Signature: Date: =.,� r
Address.of New Home: City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
1/11/2017 12:10 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1
FORM 1U05-2014
FLOORS.
# Floor Type _Space _P_erimeter,Perimeter R-Value Area Joist R-Value Tile. Wood Carpet
6Slab-On-Grade Edge Insulatio MASTER BEDRO 12 ft Y _. —._O __ 172 fr7.__. _0.__. � 0 .
7 Slab-On-Grade Edge Insulatio NEW CLST. 24 It 0 - 70 ftz ___ 0•- 1 0
8 Slab-On-Grade Edge Insulatio FOYER 8 ft 0 206 ft2 _ 0 1 0
9 Slab-On-Grade Edge Insulatio BEDROOM 4 32 ft 0 •l50 ft2 0 1 0
1051ab-On-Grade Edge Insulatio BEDROOM 3 29 ft 0. 196 ft2 _Y 0 1 0
11SIab-On-Grade Edge Insulatio LIVING loft 0 100 ft2 _ 0 1 0
12SIab-On-Grade Edge Insulatio. BATH 2 8 ft 0 64 ft2 _w 0 1 0
ROOF
j Roof Gable Roof Solar SA Emitt, Emitt Deck Pitch
# Type Materials , Area Area Color Absor. Tested Tested Insul. (deg)
1 Gable or Shed Composition shingles 1921 ft2 304 ft2 Medium 0.6 No 0.9 No 0 18.4
:ATTIC ;
# Type Ventilation Vent Ratio(1 in) . Area RBS IRCC
1 Full attic : Vented 150 1823 ft' N N
CEILING
#� Ceiling Type _ _ Space R-Value �!ns Type Area Framing Frac Truss Type,
1 Under Attic(Vented) BATH 3 30 T Blown' 72 ft2 0.1 Wood
2 Under Attic(Vented) BEDROOM 2 30 Blown '210 ft2 0.1 Wood
3 Under Attic(Vented) FAMILY 30 Blown 286 ftz 0.1 Wood
4 Under Attic(Vented) KITCHEN 30 Blown, 234 ft2 0;1 Wood . ,
5 Under Attic(Vented) M BATH 30 Blown. 63 ft2 0.1 Wood
6 Under Attic(Vented) , MASTER BEDRO 30 Blown 172 ft2 0.1 Wood
7 Under Attic(Vented) NEW CLST. 30 Blown 70ft? 0.1 Wood'
8 Under Attic(Vented) FOYER 30 Blown 205 ft2 0.1 Wood
9 Under Attic(Vented) BEDROOM 4 30 Blown 150 ft2 0.1 Wood
10 Under Attic(Vented), BEDROOM 3 30 Blown 196 ft2. 0.1 Wood
11 UnderAttic(Vented) LIVING 30 Blown> 100ft2, 0.1 Wood
12 Under Attic(Vented) BATH 2 30 Blown 64 ft2 0.1- Wood "
WALLS
/ Adjacent Cavity Width Height Sheathing framing Solar Below
1/.__#. Omt-:---To--=- Wa1LType Spa ...—R-Value. Ft---tn_—.Ft:._-In... Area_---R-Value-._Fraction Absor._-.Grade%-
1 N Exterior Concrete Block-Ext Insul BATH 3 4.1 8 0 9 ' 0. 72.0 ftz 0 0 0.6 0
i 2 S Exterior Concrete Block-Ext In6ul BATH 3 4.1 3 0 9 0 , 27.0 ft2 0 0 0.6 0
3 W Exterior Concrete Block-Ext Insul BATH 3 4.1 9 0 9 0 81.0 ft2 0 " 0' 0.6 0
4 E Exterior Concrete Block-Ext InfiffDROOM 2 4.1 2 0 9 0 18.0 ft2 0 01 0.6, 0
1111/2017 12:10 PM, EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5
FORM R405 2014
PROJECT
Title: BRENDA HOLLAND Bedrooms: 4 Address Type: Street Address
Building Type: User Conditioned Area: 1823 Lot#
Owner. Total Stories: 1 Block/SubDivision:
#of Units: 1 Worst Case: No PlatBook:
Builder Name: Rotate Angle: 0 Street: 469 SE NARANJA AV
Permit Office: Cross Ventilation: No County: ST.LUCIE COUNTY
Jurisdiction: Whale House Fan: No City,State,Zip: PORT ST_LUCIE,
Family.Type: Single-family FL,
New/Existing: Addition
Comment:
CLIMATE
/ IECC Design Temp . Int Design Temp Heating Design Daily Temp
1/ Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Fort Pierce FL_VERO_BEACH MUNI 2 39! 90 70 75 299 62 Low
BLOCKS
Number Name Area Volume
1 Entire House 1823 16407
SPACES
p Bedrooms InfilID Finished Cooled Heated
Number Name � _ _ —^Area Volume Kitchen Occupants,_ � •___.-1..,
1 BATH 3 72 648 No 0 1 Yes. Yes Yes
2 BEDROOM 2 210' 1890 No 2 1 1 Yes Yes Yes
3 FAMILY 286 2574 No- 0 1 Yes Yes Yes
4 KITCHEN 234 2106 Yes 2 1 No Yes Yes
5 M BATH 63 567 No 0 1 Yes Yes Yes
6 MASTER BEDR00 172 1548 No 2 1 1 Yes Yes Yes
7 NEW CLST. 70 630 No 0 1 Yes Yes Yes
8 FOYER 206 1864 No 0 1 Yes Yes Yes
9 BEDROOM 4 150 1350 No 0 1 1 Yes Yes Yes
10 BEDROOM 3 196 1764 No 0 1 1 Yes Yes - Yes
11 LIVING 100 900 No 0 1 Yes Yes Yes
12 BATH 2 64 576 No 0 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio 'BATH 3 20 ft 0 72 ft2 __-_ 0 1 0
2 Slab-On-Grade Edge Insulatio BEDROOM 2, 31 It 0 210 ft2 0 1 0 .
3 Slab-On-Grade Edge Insulatio FAMILY . 39 ft 0 286 ft2 __ _ 0 1 0
4 Slab-On-Grade Edge Insulatio KITCHEN 1 ft 0 234 ft2 ___ 0 1 0
5 Slab-On-Grade Edge Insulatio M BATH 7 ft 0 63 ft2 __-- 0 1 0
111112017 12:10 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: BRENDA HOLLAND Builder Name:
Street: 469 SE NARANJA AVENUE Permit Office:
City,State,Zip: PORT ST.LUCIE,FL, Permit Number:
Owner. Jurisdiction:
Design Location: FL..Fort Pierce
COMPONENT CRITERIA CHECK
Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air-permeable insulation shall not be used as a sealing material.
Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings,drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Comers and headers shall be insulated and the junction of the foundation
Walls and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors The space between window/doorjambs and framing and skylights and
framing shall be sealed.
Rim joists Rim joists are insulated and include an air barrier.
Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors) of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls Where provided in lieu of floor insulation,insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated,and sealed to the drywall.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub-floor or drywall.
Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
1/11/2017 12:11 PM EnergyGauge®USA-FlaRes2014'Section R405.4'A Compliant Software Page 1 of 1
FORM R405-2014
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA- ACH ACH 50
-------------
I Wholehouse Proposed ACH(50) .0004 1914.2 105.08 197.63 .2922 , 7
HEATING SYSTEM
System Type `v Subtype _— —_ Efficiency Capacity Block Ducts
1 Electric Strip Heat None COP:1 27 kBtu/hr 1^ sys#1
COOLING SYSTEM
#, System Type — --_ Subtype ` _ Efficiency Capacity_ Air Flow SHR_ Block _Ducts _
1 Central Unit Split SEER: 15 41 kBtu/hr y cfm 0.8 _ 1 sys#1
SOLAR HOT WATER SYSTEM77 .
FSEC Collector Storage
Cert # Company Name System.Model# Collector Model#. Area Volume FEE
DUCTS
/ ---Supply-- ----Return— Air CFM 25 CFM25 HVAC#
1/ # Location. R-Value Area Location Area Leakage Type Handier TOT . OUT QN RLF Heat Cool
1 Attic 6 325 ft2 Attic 105 ft' Default Leakage FOYER (Default) (Default) 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
CoolingJan Feb Mar A r Ma X Jun Jul AugSe Oct Nov Dec
Ventin Jan Feb Mar ' �C�Apr May Jun Jul Aug rl
Sep �X�Oct Nov
Nov LX Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8. 9 10 11, 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 8b 80 80
PM 80 80 . 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 '78 78 . 78 , ' 78
PM 78 78 78 78 78 78 78 78 78 78• --.78 78
Heating(WD) AM 66. 66 66 66 66 68 68 68 68 68 68 68
PM '68 68 68 68 68 68 68 68 68 68 66 66
Heating(1WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68- ' 65 66
1/1112017 12:10 PM EnergyGaugeJ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5
FORM R405-2014
WALLS
V/ Adjacent e Cavity Width Height Sheathing Framing Solar Below
--#_--Ornt-----To ----.Wall Type--...__ �.._- Spats ..__R-Value--_.__Ft -In._-..Ft ._In-- Area_.... R-Value Fraction. Absor__Grade%_
5 S Exterior Concrete Block-Ext InfiEDROOM 2 4.1 15 0 9 0 135.0 ft2 0 0 0.6 0
6 W Exterior Concrete Block-Ext InfiffDROOM 2 4.1 14 0 9 0 126.0 ft2 0 0 0.6 0
7 N Exterior Concrete Block-Ext Insul FAMILY 4.1 26 0 9 0 234.0 ft2 0 0 0.6 0
8 E Exterior Concrete Block-Ext InsulFP.MILY 4.1 2 0 9 0 18.0 ft2 0 0 0.6 0
9 W Exterior Concrete Block-Ext Insul FAMILY 4.1 11 0 9 0 99.0 ft2 0 0 0.6 0
a 10 E Exterior Concrete Block-Ext InsulM BATH 4.1 1 0 9 0 9.0 ft2 0 0 0.6 0
r 11 S Exterior Concrete Block-Ext InsulM BATH 4.1 6 0 9 0 54.0 ft2 0 0 0.6 0
_12 E Exterior Concrete Block-Ext InddASTER BE -4.1 7 0 9 0 63.0 ft2 0 0 0.6 0
_13 S Exterior Concrete Block-Ext InsMASTER BE 4.1 2 0 9 0 18.0 ft2 0. 0 0.6 0
_14 W Exterior Concrete Block-Ext Ins)A14STER BE 4.1 3 0 9 0 27.0 ft2 0 0 0.6 0
15 E Exterior Concrete Block-Ext InsWEW CLST. 4.1 7 0 9 0 63.0 ft2 0 0 0.6 0
_16 S Exterior Concrete Block-Ext lnsHEW CLST. 4.1 10 0 9 0 90.0 ft2 0 0 0.6 0
17 W Exterior Concrete Block-Ext InsblEW CLST. 4.1 7 0 9 0 63.0 ft2 0 0 0.6 0
18 S Exterior Concrete Block-Ext Insul FOYER 4.1 8 0 9 0 72.0 ft2 '0 0 0.6 0
19 E Exterior Concrete Block-Ext InOEDROOM 4 4.1 10 0 9 0 90.0 ft2 0 0 0.6 0
20 S Exterior Concrete Block-Ext InfiffDR00M 4 4.1 15 0 9 0 135.0 ft2 0 0 0.6 0
+21 W- Exterior Concrete Block-Ext InGEDROOM 4 4.1 7 0 9 0 63.0 ft2 0 0 0.6 0
_+22 N Exterior Concrete Block-Ext IneEDROOM 3 4.1 15 0 9 0 135.0 ft2 0 0 0.6 0
23 'E Exterior Concrete Block-Ext InQEDROOM 3 4.1 14 0 9 0 126.0 ft2 0 0 0.6 0
+24 N Exterior Concrete Block-Ext Insul LIVING 4.1 10 0 9 ,. 0 90.0 ftZ 0 0 0.6- 0
25 E Exterior Concrete Block-Ext Insul BATH 2 4.1 8 0 9 0 72.0 ftZ 0 0 0.6 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 W Insulated BEDROOM 2 None .39 3 7 21 ft2
2 S Insulated FOYER None .39 6 6 10 41 ft2
WINDOWS
Orientation shown is the entered,Proposed orientation.
Well - Overhang
# Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 N 1 Metal Low-E Double Yes 0.65 0.25 9.5 ft2 2 ft 0 in 1 ft 4 in None None
2 S 5 Metal Low-E Double Yes 0.65 0.25 10.8 ft2 2 ft 0 in 1 ft 4 in None None
3 N 7 Metal Low-E Double Yes 0.65 0.25 91.9 ft2 2 ft 0 in 1 ft 4 in None None
4 W 9 Metal Low-E Double Yes 0.65 0.25 20.4 ft2 2 ft 0 in 1 ft 4 in None None
5 W 9 Metal Law-E Double Yes 0.65 0.26 23.0 ft2 2 ft 0 in 1 ft 4 in None None
6 S 11 Metal Low-E Double Yes 0.65 0.25 9.6 ft2 2 ft 0 in 1 ft 4 in None None
7 E 19 Metal Low-E Double Yes 0.65 0.25 15.0 ft2 2 ft 0 in 1 ft 4 in None None
6 S 20 Metal Low-E Double Yes 0.65 0.26 15.0 112 2 ft 0 in 1 ft 4 in None None
9 N 22 Metal Low-E Double Yes 0.65 0.25 23.0 ft2 2 ft 0 in 1 ft 4 in None None
10 E 23 Metal Low-E Double Yes 0.65 0.25 13.0 ft2 2 ft 0 in 1 ft 4 in None None
11 N 24 Metal Low-E Double Yes 0.65 0.25 23.0 ft2 2 ft 0 in 1 ft 4 in None None
12 E 25 Metal Low-E Double. Yes 0.65 0.25 6.0 ft2 2 ft 0 in 1 ft 4 in None None
1/11/2017 1210 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5
. ® ww,wmnswwmewxmvv -
�ntivaanmm[,vsmm
mae.m,cawmaro»mtumwowmmnvamovam,nc p ��yg � _
im�M�omr�mr1°amov��m.�Omm°si°rmm�n itnnamamuc,rcmnrtemvwa 191�` �� �GIL�xTO
GOOK NOM
munui.Qn.m@Tnwmaw[ameimrmnrw¢rvm.nm l6aict8— lit
4mliLM,Yw[i®wtta•I W 11[1•R1Q6LDpLL1YMMwi W,
mmam«am[nawMicm. I1VNC BmP00M3
wiwum:mvmxnvnuuics�m•v,m•amQma m m.r«...� �r.W I I
mm-m..arw•F m anwgFOa•w[mmm 'w=n
m•mu•o�manmmncxxwm@,vavwcm["aar p _� 4 141C�m -' e
nmr:n p W
mmiamaiomuimursam[mm ,mom ••' r, —_ -- �� 0
xuvcrwomwm®im.�%aarcrana@us.�m.ma ®u � vl .��i ! �ias•�s.ucnrva J
ewmmm�ruoaimcu.omamrnmcmwomaa.onwva "' n.me,.occv� I
ae�ivmmwo�m.awms•.,n mvK,wwuws,mwnmo (Qylgytp .ocn wadema I 4 y V-
wmeommoM . w.umm �1fo1c0 ®ar�.�amn.w..a p ¢Q0$n�
w.cuwa•�omr�..usi�w•pOve-oo�oi"m®wu r z � :c.e"'"mmwa "M� �mimmaeaw.e 6 a0W m�`a
mmar[mw®m[®.i� mr w,.om qy om ma
�:,;n�-�m•nM..ncawv,uaermammatt rrm l cmw•+ �. [wu >u g�, r
ww�eoam mvrwu•uw.umrmnmMmwmsa.Fm rwu q — '�—
amF v �muim�ovmma.a.vciemamu 01Hp . . �� '10• m� ennmoou2 p 613 w Y)ON
tl®tltlww,mmrimmnamn wmwvnm r arc h r Va�WE ,t
ummuim.mmtlanw,aniawmrrrmmmcnrommum, npwc Q LU
10
.,mr9icAW FWM q• m Jm
mic+vmm•..,wmmau.lF•i•ra.ncmu •'P�iaaarz:l�:' LL ® 4" ' ) a a G io a
mm••u[mwam�we�.nv�. mrnimre�va,•'• N� .,,�,,�7
mm�mmmmmnr.meaTmw�,w.nuamon � vumaaaom 1H11 ��"�+1 POOA14
•a•mmuu.
mww arrow 1141FaMmwrr]@IMM11061. <,,�` MRs1H1 �
flENGVA710N HEQUIPEMBJB "° ' )v q OMDOM I m p
ua®mnni us.w u'arwvn>ne•.vamM `�' uo�i,rtLro 0
nmmmoozma.. mwwuMimreonwmvia �a .iwwemr W
m.�BllmtmlAm[i�'ImBw8EtLL0RlenliS. • m� ��[�® Z_
Fla®.,9P.1Ta `� � n3,XlwOFiw• p I"' a
9l@rwl[ilA lmfIOTFRIO[VmNmIitAOmiR9iYl0® nmaw.umm exwomp me.amm � 0 n
PROPOSED FLOOR PLAN
m: SME va=r Iz —p
c) Id
co i2 m
W v!
i� NYA S�IMOC TTIE WMf.WT.Yl•0.gia•R.Xwm[ARE Y.AgR� 101wY6
- �� � a. � m s o I•" n
}i WINDOW SCHEDULE ;4.'=�M�e`.m".."'""a""'�`°"^~A' g Z m
m= nvw w
cuss rrm nmv.wra
O wunox sre TYPE wm Wn, muT a•ero we wf, -, .i-niB.. F �^s � J W ¢ �
LL
rum l�mr® L
O0 -ai w
W TA z H
y ZW
i.
WINDOW AND DOOR NOTES DOOR NOTES Q' Q n.
bpi.m[ p
mn naairwv 1°A001^O mzwomF v0wimaw� aw�•ni."ir:.nm�iunanca. .mamma.'coon—wu.�ueaw'�rtm.o� r°1LLioi '1 m .BLOCK-UP DOOR DETAIL
-w�`w4•aC6ac3im1wc6wwu0h,Vwmm[ei[m4 �:n�®��m,�.m�,[�:
um®avacmtlmrrervv®.wn�•sc�vrar� � i w�a[w Fam m...•wFq.wa.,a.nn[mtluwormw@
a' :®:m�.Fo. :�wi m:,n�`a®mmon:l�,•ree�nw� �v...,m[inmw,®�'®
wF® o09m®vm�ma[Pa,-b+u.w®�iCMa�m�u n��o®ltP pvs•�•Y.T SOW aOrnE.Pnu
-9�l®te��C� mm,m�w1487m�FNlif artmenwiCiM •.
lIO.,Dnma1RPNY0iu�w[IbmiwnMFsaFfai®1s]nP90m2 uWivLmu��.FPGtmtllvaR1WFN@•S,m.
m,q➢p,{m10 matli.A�w�wCnFM1.eOtlpmmF,a
FPuwn.i,rw ,artaWoma•aaa� r,mm
ac
mrdmeatl
mnw�.¢oumvm.mwwiwmr.�wc,marpe 4'/!16 AG`
DETAIL Tw.mmc91
S�3M_,..W A-2
OF7
Pro ect Summa Job:
'
E WPI �7tS®ft' , � Date: Jan 11,2017
9 Entire House By:
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34M Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM
Project Information
For. BRENDA HOLLAND
469 SE NANRANJA AVENUE, PORT ST. LUCIE, FL34983
Notes:
Design Information
Weather. Fort Pierce, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 42 OF Outside db 90 OF
Inside db 70 OF Inside db 75 OF
Design TD 28 OF Design TD 15 OF
Daily range L
Relative humidity 50 %
Moisture difference 61 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 24200 Btuh Structure 19135 Btuh
Ducts 6507 Btuh Ducts 10521 Btuh
Central vent (65 cfm) 2010 Btuh Central vent (65 cfm) 1077 Btuh
Outside air Outside air
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 32717 Btuh Use manufacturer's data n
Rate/swing multiplier 0.95
Infiltration Equipment'sensible load 29196 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 3485 Btuh
Ducts 2874 Btuh
Central vent(65 cfm) 2728 Btuh
Heatingg Cooling Outside air
Area(ft2) 1823 1823 Equipment latent load 9087 Btuh
Volume(ft3) 16407 16407
Air changesthour 0.38 0.20 Equipment total load 38283 Btuh
Equiv.AVF(cfm) 104 55 Req. total capacity at 0.70 SHR 3.5 ton
Heating Equipment Summary Cooling Equipment Summary
Make Make American Standard
Trade Trade AMERICAN STANDARD
Model Cond 4A7A4042L1
AHRI ref Coil TEM4AOC42S41++TDR
AH R I ref 7502901
Efficiency 100 EFF Efficiency 12.5 EER, 15 SEER
Heating input 5.1 kW Sensible cooling 28700 Btuh
Heating output 17448 Btuh Latent cooling 12300 Btuh
Temperature rise 50 OF Total cooling 41000 Btuh
Actual air flow 318 cfm Actual air flow 1367 cfm
Air flow factor. 0.010 cfm/Btuh Air flow factor 0.046 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.77
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
r wrightsoft' 2017-Jan-11 12:08:38
Right-Sufte®Universal 2017 17.0.14 RSU08101
Page 1
At CAUserslQuick Calcs\Documents\HOLLAND,BREAND.rup Cale=MJ8 Front Door faces: N
}
►'.
,�,,
. ,
:�
�.
,� y
,a,
r� C
}' � ,,+�
,.
u`
A
`ir�r;:�:r
.. !:�.
Yw ;�
- wrightsoft' Right-M Worksheet Job.
Entire House Date: Jan 11,2017
By:
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772466-6799 Fax 772-466.6796 Email:QUICKCALCS@AOL.COM
1 Room name Entire House BATH 3
2 E,posed wall 220.0 ft 20.0 ft
3 Room height 9.0 ft d 9.0 ft heat/cool
4 Room dimensions 8.0 x 9.0 ft
5 Room area 1823.0 ftz 72.0 ft'
Ty Construction U-wlue Or HTM Area (ft� Load Area (ft-) Load
number (Btuh/ft;°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 13AAocs 0.143 n 4.00 2.55 531 384 1536 976 72 - 62 250 159
4A5-2om 0.770 n 21.56 19.31 10 0 207 185 10 0 207 185
4A5-2om 0.770 n 21.56 19.31 138 0 2971 2661 0 0 0 0
444���III 13AAocs 0.143 a 4.00 2.55 459 425 1702 1082 0 0 0 0
11 4A5-2om 0.770 a 21.56 42.10 6 1 129 253 0 0 0 0
4A5-2om 0.770 a 21:56 45.10 15 1 323 677 0 0 0 0
4A5.2om 0.770 a 21.56 45.44 13 1 280 691 0 0 _ 0 _ 0
13AAocs 0.143 s 4.00 2.55 531 455 1821 1158 27 27 108 69
4A5-2om . 0.770 s 21.56 19.31 10 1.0 207 185 0 0 0 0
4A5.2om - 0,770 s 21.56 19.31 - 11 11 233 209 0 0 0 0
4A5-2om 0.770 s 21.56 19.31 15 15 323 290 0 0 0 0
11 DO 0.390 -s 10.92 11.31 41 41 446 461 0 0 0 _ 0
13A-4ocs 0.143 w 4.00 2.55 459 395 1580 1004 81 81 324 206
1OD-m 1.390 w 38.92 38.45 20 1 794 784 0 0 0 0
4A5-2om 0:770 w 21.56 45.18 23 2 495 1038 0 0 0 0
11 DO_ 0.390 w 10.92 11.31 21 21 229 238 0 0 0 0
C 166-30ad 0.032 0.90 1.68 1823 1823 11633 3063 72 72 65 121
F 22A-tpl 0:989 - 27.69 0.00 1823 220 6092 0 72 20 554 0
6 c)AED.exursion 0 -16
Envelope loss/gain 21003 14853 1508 724
12 a) Infiltration 3198 902 291 82
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 6 1380 0 0
Appliances/other 2000 0
Subtotal Qines 6 to 13) 24200 19135 1798 806
Less e)demal load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 24200 19135 1798 806
15 Duct loads 27% 550/0 6507 10521 •27% 55% 484 443
Total room load 30707 29656 M82 1248
Air required(cfm) 318 1367 1 24 58
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
wrightsoft" 2017-Jan-11 1 Right-Suite®Universal 2017 17.0.14 RSUO8101 Pagel
C:\Users\Quick Calcs\Documents\HOLLAND,BREAND.rup Calc=MJ8 Front Door faces: N
wrightsoft• Right-M Worksheet Job:
Entire House Date: Jan 11,2017
By:
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone;772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM
1 Room name BEDROOM 2 FAMILY
2 Exposed wall 31.0 ft 39.0 ft
3 Room height 9.0 ft heat/cool 9.0 ft heat/cool
4 Room dimensions 15.0 x 14.0 ft 26.0 x 11.0 ft
5 Room area 210.0 ft' 286.0 ftz
Ty Construction U-glue Or HTM Area (ftj Load Area (W) Load
number (Btuh/ft-°F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cod Gross N/P/S Heat Cod Gross N/P/S Heat Cool
6 13A-4ocs 0.143. n 4.00 2.55 0 0 0 0 234 142 569 362
Tj 4A5-2om 0.770 n 21.56 19.31 0 0 0 0 0 0 0 0
4A5-2om _ 0.770 n 21.56 19.31 0 0 0 0 92_ 0 1981 1774
VV��JJ 13AAocs 0.143 a 4.00 2.55 18 18 72 46 18 18 72 46
11 I--G 4A5-2om 0.770 - e 21.56 42.10 0 0 0 0 0 0 0 0
�L�C 4A5-2om 0.770 a 21.56 45.10 0 0 0 0 0 0 0 0
4A5-to.,.m...., 0.770 _e 21.56 45.44 0 0 0 0 0 0 _ 0 0
13A-4ocs 0.143 s 4.00 2.55 135 124 497 316 0 0 0 0
4A5.2om 0.770 s 21.56 19.31 0 0 0 0 0 0 0 0
4A5.2om 0,770 s 21.56 - 19.31 11 11 233 209 0 0 0 0
4A5-2om 0.770 s 21.56 19.31 0 0 0 0 0 0 0 0
11 DO 0.390 s 10.92 11.31 0 0 0 0 0 0 0 0
w 13A-4ocs 0.143 w 4.00 2.55 126 105 420 267 99 56 223 142
10D-m 1.390 w 38.92 38.45 0 0 0 0 20 1 794 784
4A5-2om 0.770 w 21.56 45.18 0 0 0 0 23 2 495 1038
D 11DO 0.390 w 10.92 11.31 21 _ _ 21 229 238 0 0 _ 0 0
C .16B-30ad _ _ 0.032 - 0.90_ _ 1.68 210 210 188 353 286 286 256 _ 480
F 22A-tpl 0.989 - 27.69 0.00 210 31 858 0 286 39 1080 0
6 c)AED exursion -40 287
Envelope loss/gain 2499 1388 5470 4913
12 a) Infiltration 451 127 567 160
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 2 460 0 0
Applianceslother 0 0
Subtotal pines 6 to 13) 1 2949 1975 6037 5073
Less extemal load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 2949 1975 6037 5073
15 Duct loads 27% 55% 793 1086 27% 55% 1623 2789
Total room load 3742 3061 7660 7862
Air required(cfm) I 1 1 39 1411 1791 362
Calculations approved bvACCA to meet all requirements of Manual J 8th Ed.
444- wrightsoft• 2017-Jan-11 12:08:38
Right-Suite®Universal 2017 17.0.14 RSLI08101 page 2
C:\Users\Quick Calcs\Documents\HOLLAND,BREAND.rup Calc=MJ8 Front Door faces: N
+ wrightsoft• Right-JO Worksheet Job:
Entire House Date: Jan 11,2017
By:
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM
1 Room name KITCHEN M BATH
2 E)posed wall 0 ft 7.0 ft
3 Room height 9.0 ft heat/cool 9.0 ft heat/cool
4 Room dimensions 26.0 x 9.0 ft 1.0 x 63.0 ft
5 Room area 234.0 ft2 63.0 ft2
Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load
number (Btuh/ft L.F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cod Gross I NIP/S Heat Cool
6 V[ 13AAocs 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0
LI-�G 4A5-2om 0.770 n 21.56 19.31 0 .0 0 0 0 0 0 0
4A5-2om 0.770 n 21.56 19.31 0 0 0 0 0 0 0 0
T-G
13A flocs 0.143 a 4.00 2.55 0 0 0 0 9 9 36 23
11 4A5-2om 0.770 a 21.56 42.10 0 0 0 0 0 0 0 0
4A5-2om 0.770 a 21.56 45.10 0 0 0 0 0 0 0 0
4A5-2om._ 0.770 e. 21.56 45.44 0 0 0 0 0 0 0 0
W 13AAocs 0.143 s 4.00 2.55 0 0 0 0 54 44 178 113
4A5-tom - 0.770 s 21.56 19.31 0 -0 0 0 10 10 207 185
4A5-2om 0.770 s 21.56 19.31 0 0 0 0 0 0 0 0
4A5-2om 0.770 s 21.56 19.31 0 0 0 0 0 0 0 0
11DO 0.390 s 10.92 11.31 0 0 0 0 0 0 0 0
WI - 13A-4ocs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0
10D-m 1.390 w 38.92 38.45 0 0 0 0 0 0 0 0
4A5-2om 0.770 w 21.56 45.18 0. 0 0 0 0 0 0 0
L� 11 DO 0.390 w 10.92 11.31 0 0 0 0 0 0 0 0
C 16B-30ad 0.032 - 0.90 1.68 234 234 210 393 63 _ 63 56 106
F 22A-tpl 0.989 - 27.69. 0.00 234 0 0 0 63 7 194 0
6 c)AED excursion -57 -9
Envelope loss/gain 210 336 671 418
12 a) Infiltration 0 0 102 29
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 2 460 0 0
Appliances/other 20M 0
Subtotal(lines 6 to 13) 210 2796 773 447
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 210 2796 773 447
15 Duct loads 270/6 55% 56 1537 27% 55% 208 246
Total room load 266 4333 981 692
Air required(cfm) 3 200 10 32
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
fII wrightsoft 38
Right-Suite®Universal 2017 17.0.14 RSLI08101 2017-Jan-11 12: ge
Page 3
3
C:\Users\Quick Calcs\Documents\HOLLAND,BREAND.rup Calc=MJ8 Front Door faces: N
+ -- wrightsoft` Right-M Worksheet Job:
Entire House Date: Jan 11,2017
By:
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM
1 Room name MASTER BEDROOM NEW CLST.
2 E)pOsed wall 12.0 ft 24.0 ft
3 Room height 9.0 ft heat/cool 9.0 ft heat/cool
4 Room dimensions 1.0 x 172.0 ft 10.0 x 7.0 ft
5 Room area 172.0 ftz 70.0 ft=
Ty Construction U-value Or HTM Area (ft� Load Area (ft� Load
number (Btuhlft;°F) (Btu or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cod Gross N/P/S Heat I Cool
6 1N 13A4ocs 0.143 n 4.00 2.55 0 -0 0 0 0 0 0 0
II-_GG 4A5.2om 0.770 n 21.56 19.31 0 0 0 0 0 0 0 0
4A5-2om 0.770 n 21.56 19.31 0 0 0 0 0 0 0 D
\VV���JJJ 13A-4ocs 0.143 a 4.00 2.55 63 63 252 160 83 63 252 160
11 4A5-2om 0.770 a 21.56 42.10 0 0 0 0 0 0 0 0
4A5-2om 0.770 a 21.56 45.10 0 0 0 0 0 0 0 0
4A5.2om 0.770 a 21.56 45.44 0 0 0 0 0 0 0 0
W 13A-4ocs 0.143 s 4.00 2.55 16 18 72 46 90 90 360 229
4A5.2om 0.770 s 21.56 19.31 0, 0 0 0 0 0 0 0
4A5-2om 0.770 s 21.56 19.31 O= 0 0 0 0 0 0 0
4A5-2om 0.770 s 21.56 19.31 0 0 0 0 0 0 0 0
11DO 0.390 s 10.92 11.31 .0 0 0 0 0 0 0 0
13A-4ocs 0.143 w 4.00 2.55 27 27 108 69 63 63 252 160
1OD-m 1.390 w 38.92 38.45 0 0 0 0 0 0 0 0
4A5-2om 0.770 w 21.56 45.18 0 0 0 0 0 0 0 0
11DO 0.390 w 10.92 11.31 0 0 0 0 0 - 0 0 0
C 16B-30ad 0.032 0.90 1.68 .172 172 154 289 70 70 63 118
F 22A-tpl 0.989 - 27.69 0.00 172 12 332 0 ,70 24 665 0
6 c)AED excursion -21 -15
Envelope loss/gain 919 542 1592 652
12 a) Infiltration 174 49 349 98
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 2 460 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 11093 1052 1941 1750
Less extemal load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 1093 1052 1941 750
15 Duct loads 27% 550/0 294 578 270/6 550/0 522 413
Total room load 1387 1630 2463 1163
Air required(cfm) 1 14 75 1 25 54
Calculations approved bVACCA to meet all requirements of Manual J 8th Ed.
-Fk- w,1ghtsc ft- 2017-Jan-11 12:08:38
Right-Suite®Universal 2017 17.0.14 RSLI08101 Page 4
3 ~ C:\Users\Quick Calcs\Documents\HOLLAND,BREAND.rup Calc=MJ8 Front Door faces: N
+}#- wrightsoft• Right-M Worksheet Job:
Entire House Date: Jan 11,2017
_ By:
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM
1 Room name FOYER BEDROOM 4
2 Exposed wall 9.0 ft 8.0 ft heat1cool 9.0 ft 320 ft heat/cool
3 Room height
4
5 Room dimensions 1.0 x 206.0 ft 15.0 x 10.0 ft
Room area 206.0 ft2 150.0 ft2
Ty Construction U-value Or HTM Area (ft2) Load Area (ft') load
number (Btuh/ft;°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross NIP/S Heat Cool Gross N/P/S Heat Cool
6 13A-4ocs AM n 4.00 2.55 0 - 0 0 0 o _ 0 0 0
4A5-2cm 0.770 n 21.56 19.31 0 0 0 0 0 0 0 0
4A5-2om 0.770 n 21.56 19.31 0 0- 0 0 0 0 0 0
VVVJJJJJJ 13A-4ocs 0.143 a 4.06 2.55 0 0 0 0 90 75 300 191
11 4A5.2om 0.770 a 21.56 42.10 0 0 0 0 0 0 0 0
4A5.2om 0.770 a 21.56 45.10 0 0 0 0 15 1 323 677 -
4A5.2om_ 0.770 _e 21.56 45.44 0 0 0 -0- --0- 0 _ , 0 0
43 V11 13A-4ocs 0:1 s 4.00 2.55 72 31 125 79 135 120 480 305
4A5-2om 0:770 -s 21.56', 19.31 0 0 0 0 0 0 0 0
4A5-2om 0.770 s 21.56 19.31 0 0 0 0 0 0 0 0
4A5-2om 0.770 s' 21.56 19.31 "0 0 0 0 15 15 323. 290
-D ADO 0.390 .s-' 10.92: 11.31 41 • - 41 446. 461 _- - 0 0 0 0
W 13A-4ocs 0.143 w 4.00 2.55 0 0 0 0 63 63 252 160
10D-m 1.390 w 38.92 38.45 0 0 0 0 0 0 0 0
4A5-2om 0.770 w 21.56 45.18 0 0 0 0 0 0 0 0
11DO 0.390 .w 10.92 .-. 11.31 0 0 0- 0 0 0 _ 0 _ _ 0
C 16B-30ad 0.032 - _ 0.90 1.68 206 _ 206, _ _185 346 - 150 - 160 -_ _ 134. -252
F 22A-tpl- 0.989 - 27.69 0.00 206 8 222 ._ 0 150 32 8W 0
6 c)AED excursion -18 A0
Envelope loss/gain 977 869 2700 1835
12 a) Infiltration 116 33 465 131
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal Vines 6 to 13) 1093 901 3165 19N
Less e)demal load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 1093 901 3165 19N
15 Duct bads 271/6 55% 294 496 27%1 559/o 1 B51 1081
Total room load 1387 1397 4017 3047
Air required(cfm) 14 64 42 140
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
.� � wrig sn htfV 2017-Jan-1112:08:38
A& Right-Suite®Universal 2017 17.0.14 RSU08101 Page 5
C:\Users\Quick Calcs\Documents\HOLLAND,BREAND.rup Calc=MJ8 Front Door faces: N
-r• wrightsoft• Right-JO Worksheet Jab.
• Entire House Date: Jan 11,2017
By:
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM
1 Room name BEDROOM 3 UVING
2 Exposed wall 29.0 ft 10.0 ft
3 Room height 9.0 ft heat/cocl 9.0 ft heat/cod
4 Room dimensions 1.0 x 196.0 ft 10.0 x 10.0 ft
5 Room area 196.0 ft' 100.0 ft'
Ty Constriction U-value Or HTM Area (ft� Load Area (ft5 Load
number (Btuh/ftk-T) (Btuh/ft2) or perimeter (ft) (Btuh) or. perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cod Gross N/P/S Heat Cool
6 13A-4ocs 0.143 n 4.00 2.55 135 112 449 285 90 61 258 171
4A5-2om 0.770 n 21.56 19.31 0 0 0 0 0 0 0 0
4A5-2om 0.770 n 21.56 19.31 23 0 495 443 23 0 495 443
VVVNNN 13A4ocs 0.143 a 4.00 2.55 126 113 452 288 0 0 0 0
11 4A5.2orn 0.770 a 21.56 42.10 0 0 0 0 0 0 0 0
4A5.2om 0.770 a 21.56 45.10 0 0 0 0 0 0 0 0
4A5.2om 0.770 a 21.56_ 45.44 13 1 280 591 0 0 _ 0 0
13A4ocs 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0
4A5-2om. 0.770 s 21.56 19.31 0 0 0 0 0 0 0 0
4A5.2om 0.770 s 21.56 19.31 0 0 0 0 0 0 0 0
4A5-2om 0.770 s 21.56 19.31 0 0 0 0 0 0 0 0
11DO 0.390 s -10.92 _ 11.31 0 0 0 0 0 0 0 0
w 13A-4ocs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0
L� 10D-m 1.390 w 38.92 38.45 0 0 0 0 0 0 0 0
4A5-2om 0.770 w 21.56 45.18 0 0 0 0 0 0 0 0
11DO 0.390 w 10.92 . 11.31 0 0 0 0 0 0 0 0
C 16B-30ad 0.032 0.90 1.68 196 195 176 329 100 100 90 168
F 22A-tpl 0.989 - 27.69 0.00 196 29 803 0 100 10 277 0
6 c)AED excursion -41 -16
Envelope loss/gain 2655 1895 1130 766
12 a) Infiltration 421 119 145 41
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal pines 6 to 13) 3077 2014 1275 807
Less extemal load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 3077 2014 1275 807
15 Duct bads 27% 55% 827 1107 27% 55% 343 443
Total room load 3904 3121 1618 1250
Air required(cfm) 40 1441 17 58
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
wrightsoft' g
Right-Suite®Universal 2017 17.0.14 RSLI08101 2017 Jan 11 1 Page 6
C:\Users\Quick Calcs\Documents\HOLLAND,BREAND.rup Calc=MJ8 Front Door faces: N
-�- wrightsoft• Right-M Worksheet Job:
• • - Entire House Bate: Jan 11,2017
By:
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@40L.COM
1 Room name BATH 2
2 E)pOsed wall 8.0 ft
3 Room height 9.0 ft heat/cool
4 Room dimensions 8.0 x 8.0 ft
5 Room area 64.0 ftz
Ty Constriction U-value Or HTM Ares M Load Area Load
number (13tuh1WL F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter
Heat Cool Gross N/P/S Heat Cod Gross N/P/S Heat Cool
6 13A-4ocs 0.143 ri 4.00 2.55 0 0 0 0
4A5-2om 0.770 n 21.56 19.31 0 0 0 0
4A5-2om 0.770 n 21.56 19.31 0 0 0 0
T-G
13A-4ocs 0143 a 4.06 2.55 72 66 264 168
11 4A5-2om 0.770 a 21.56 42.10 6 1 129 253
4A5-2wn 0.770 a 21.56 45.10 0 0 0 0
4A5-2om 0.770 a 21.56 45.44 _ 0 0 0 0
13A4ocs 0.143 s 4.00 2.55 0 0 0 0
4A5-2om 0.770 s 21.56 19.31 0 0 0 0
4A5-2om 0.770 s 21.56 19.31 0 0 0 D
4A5-2om 0.770 s 21.56 19.31 0 0 0 0
11 DO 0.390 s 10.92 11.31 0 0 0 0
W 13A-4ocs 0.143 w 4.00 2.55 0 0 0 0
L�D
10D-m 1.390 w 38.92 38.45 0 0 0 0
4AS2om 0.770w 21.56 45.18 0 0 0 0
11DO 0.390 w 10.92 . 11.31 0 _ 0 0 0
C 1613-30ad 0.032 - 0.90 1.68 64 64 57 108
F 22A-tpl _ 0.989 - 27.69 0.00 64 8 222 0
6 c)AED excursion -11
Envelope loss/gain 673 517
12 a) Infiltration 116 33
b) Room ventilation 0 0
13 Internal gains: Occupants @ 230 0 0
Appliances/other 0
Subtotal Qines 6 to 13) 789 550
Less e:Qemal load 0 0
Less transfer 0 0
Redistribution 0 0
14 Subtotal 789 550
151 uct loa 01 0 212 302
Total room load 1001 852
Air required(cfm) 10 39
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
-1 wrightscAt Ri ht-Sulte®Universal 2017 17.0.14 RS1108101 2017-Jan-11 12:08:38
g Page 7
C:\Users\Quick Calcs\Documents\HOLLAND,BREAND.rup Calc=MJ8 Front Door faces: N
y P ect Summa Job:
`Wri htsoft� ro� � Date: Jan11,2017
9 Entire House By:
QUICK CALCS,-INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772466-6799 Fax 772-486-6796 Email:QUICKCALCS@AOL.COM
Project • •
For. BRENDA HOLLAND
469.SE NAN RANJA AVEN U E, PORT ST. LUCIE, FL34983
Notes:
D- • • •
Weather. Fort Pierce, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 42 OF Outside db . =90 OF
Inside db 70 OF Inside db 75 OF
Design TD 28 OF Design TD 15 OF
Daily range L
Relative humidity 50 %
Moisture.difference 61 gr/lb
Heating Summary " Sensible Cooling Equipment Load Sizing
Structure 24200 Btuh Structure 19135 Btuh
Ducts . 6507 Btuh Ducts 10521 Btuh
Central vent(65 cfm) 2010 Btuh Central vent(65 cfm) 1077 Btuh
Outside air Outside air"
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 32717 Btuh Use manufacturer's data n
Rate/swing multiplier 0.95
Infiltration Equipmenf sensible load 29196 Btuh .
Method Simplified Latent.Cooling Equipment Load'Sizing .
Construction quality Average
Fireplaces 0 Structure 3485 Btuh
Ducts 2874 Btuh
Central vent(65 cfm) 2728 Btuh
Heatingg Cool' Outside air
Area(ft2 1823 1823 Equipment latent load 9087 Btuh
Volume(fts) 16407 A6407
Air changes/hour 0.38 0.20 Equipment total load 38283 Btuh
Equiv.AVF(cfm) 104 55 Req.total capacity at 0.70 SHR 3.5 ton
Heating Equipment Summary Cooling Equipment Summary
Make Make American Standard
_ Trade Trade AMERICAN STANDARD
Model Cond 4A7A40421-1
AHRI ref Coil TEM4AOC42S41++TDR
AHRI ref 7602901
Efficiency 100 EFF Efficiency 12.5 EER, 15 SEER
Heating input 5.1 -kW Sensible cooling 28700 Btuh
Heating output 17448 Btuh Latent cooling 12300 Btuh
Temperature rise 50 OF Total cooling 41000 Btuh
Actual air flow 318 cfm Actual air flow. 1367 cfm
Air flow factor 0.010 cfm/Btuh Air flow factor 0.046 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.77
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
WrIghLSOft'• 2017-Jan-11 12:08:38
Right-Suite®Universal 2017,17.0.14 RSU06101 Page 1
ACA C:%Users%Quick C.aleslDocumentalHOLLAND,BREAND.rup Calc=MJ9 Front Door faces: N
r
Al wrightsoft' Right-JO Worksheet °b:
Entire House Date: Jan 11,2017
By:
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@,AOL.COM
1 Room name Entire House BATH 3
2 E)posed wall 220.0 ft , 20.Q ft
3 Room height 9.0 ft d 9.0 ft heat/cool
4 Room dimensions 8.0 x 9.0 . ft
5 Room area 1823.0 ftZ 72.0 ft2
Ty Construction U-value Or HTM Area (ftj Load Area (ftj Load
number (Stuh/ft;°F) (Btuh/ft2) or perimeter (ft) (Stuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cod Gross N/P/S Heat Cool
6 T- 13A4ocs 0.143 n 4.00 2.55 531 384 1536 976 72 62 250 159
14 - 4A5-2om 0.770 n 21.56 19.31 10 0 207 185 10 0 207 185
GG
4A5-2om 0.770 n 21.56 19.31 138 0 2971 2661 0 0 0 0
yyyJJJ 13A•tocs 0.143 a 4.00 2.55 459 425 1702 1082 0 0 0 0
11 4A5-2om 0.770 a 21.56 42.10 6 1 129 253 0 0 0 0
4A5-2om 0.770 a 21:56 45.10 15 1 323 677 0 0 0 0
4A5-2om 0.770 a 21.56 45.44 13 1 280 591 0 0 0 0
13A-4ocs 0.143 s 4.00 2.55 531 455 1821 1158 27 27 108 69
4A5-2om 0.770 s 21.56 19.31 10 10 207 185 0 0 0 0
4A5.2om 0.770 s 21.56 19.31 11 11 233 209 0 0 0 0
4A5-2om 0.770 s 21.56 19.31 15 15 323 290 0 0 0 0
11DO 0.390 s 10.92 11.31 41 41 446 461 0 0 0 0
13A-4ocs 0.143 w 4.00 2.55 459 395 15M 1004 81 81 324 206
10D-m 1.390 w 38.92 38.45 20 1 794 784 0 0 0 0
4A5-tom 0.770 w 21.56 45.18 23 2 495 1038 0 0 0 0
11 DO 0.390 w 10.92 11.31 21 21 229 238 0 0 0 0
C 16B-30ad 0.032 - 0.90 1.68 1823 1823 1633 3063 72 72 65 121
F 22A-tpI 0.989 - 27.69 0.00 1823 220 6092 0 72 20 554 0
6 c)AED.ex.ion 0 -16
Envelope loss/gain 21003 14853 1508 724
12 a) Infiltration 3198 902 291 82
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 6 1380 0 0
Appliances/other 2000 0
Subtotal(lines 6 to 13) 24200 19135 1798 806
Less extemal load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 24200 19135 1798 806
15 Duct bads 270/6 55% 6507 10521 27°/a 55% 484 443
Total room load 30707 29656 2282 1248
Air required(cfm) 318 1367 24 58
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
.� -�- wrightsoft' RightSuite®Universal 2017 17.0.14 RSU08101 2017-Jan-11 12:08:38
Page 1
4C C:\Users\Quick Calcs%Documents\HOLLAND,BREAND.rup Calc=MJ8 Front Door faces: N
- - wrigihtsoft' Right-l®Worksheet °b
Entire House Date: Jan 11,2017
By:
QUICK CALLS,-INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-166-6799 Fax 772-466-6796 Email:QUCKCALCS@AOL.COM
1 Room name BEDROOM 2 FAMILY
2 Exposed wall 31.0 ft 39.0 ft
3 Room height 9.0 ft heat/cool 9.0 ft heat/cool
4 Roan dimensions 15.0 x 14.0 ft 26.0 x 11.0 ft
5 Room are 210.0 ftz 286.0 W
Ty Constriction U-value Or HTM Area (ftj Load Area (ft5 Load
number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cod Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 Vr:j 13A4ocs 0.143 n 4.00 2.55 0 0 0 0 ' 234 142 569 362
4A5-2om 0.770 n 21.56 19.31 0 0 0 0 0 0 0 0
4A5.2om' 0.770 n 21.56 19.31 0 0 0 0 92 0 1981 1774
VVV,,,111fff 13A4ocs 0.143 a 4.0D 2.55 18 18 72 46 18 18' 72 46
11 4A5-tom 0.770 a 21.56 4210 0 0 0 0 0 0 0 0
4A5.2om 0.770 a 21.56 45.10 0 0 0 0 0 0 0 0
4A5-2om 0.770 a 21.56 45.44 0 0 0 0 0 0 0 0
13A4ocs 0.143 s 4.00 2.55 135 124 497 316 0 0 0, 0
4A5.2om 0.770 s 21.56 19.31 0 0 0 0 0 0 0 0
4A5-2om 0.770 s 21:56 19.31 11 11 233 209 0 0 0 0
4A5-2om 0.770• s 21.56 19.31 0 0 0, 0 0 0 0 0
11DO 0.390 s 10.92 11.31 0 0 •0 0 0 0 0 0
W 13A4ocs 0.143 w 4.00 2.55 126 105 420 267 99 56 223 142
IA10D-m 1.390 w 38.92 38.45 0 0 0 0 20 1 ' 794 784
4A5.2om 0.770 w 21.56 45.18 0 0 0 0 23 2 495 1038
11DO 0.390 w 10.92 11.31 21 21 229 238 0 0 0 . 0
C 168-30ad 0.032 - 0.90 1.68 210 210 188 353 286 286 256 480
F 22A-tpl 0.989 - 27.69 0.00 210 31 858 0 286 39 1080 0
6 c)AED excursion 40 287
Envelope loss/gain 2499 1388 5470 4913
12 a) Infiltration 451 127 567 160
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 2 460 0 0
Appliances/other 0 0
Subtotal pines 6 to 13) 2949 1975 6037 5073
Less external load 0 0 01 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 2949 1975 6037 5073
151 Duct loads 27% 55% 793 1086 27% 55% 1623 2789
Total room load 3742 3061 7660 78M
Air required(cfm) 39 141 79 362
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
4�4-- Right-Suite®Universal-2017 17.0.14 RSLI08101 2017-Jah-11 12:08:38
Page 2
C:\Users\Quick Calcs\Documents\HOLL4ND,BREAND.rup Caic=MJ8 Front Door faces: N
- - wrightsoft- RighW@ Worksheet Job.
Entire House Date: Jan 11,2017
By:
QUICK CALCS, INC.
317 ST.LUCIE W.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Emaii:QUICKCALCS@AOL.COM
1 Room name KITCHEN. M BATH
2 Exposed wall 0 ft 7.0 ft
3 Room height 9.0 it heaticool 9.0 ft heat/cool
4 Room dimensions 25.0 x 9.0 ft 1.0 x 63.0 it
5 Room area 234.0 ft2 63.0 ftz
Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load
number (Btuh/ft;°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cod Gross N/P/S Heat I Cool
6 yJ 13A4ocs 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0
II-�G 4A5-2om 0.770 n 21.56 19.31 0 0 '0 0 0 0 0 0
4A5-2om 0.770 n 21.56 19.31 0 0 0 0 0 0 0 0
VVVNNN 13A-4ocs 0.143 a 4.00 2.55 0 0 0 0 9 9 36 23
11 4A5-2om 0.770 a 21.56 42.10 0 0 0 0 0 0 0 0
4A5-2orn 0.770 a 21.56 45.10 0 0 0 0 0 0 0 0
4A5-2om 0.770 a 21.56 45.44 0 0 0 0 0 0 0 0
W 13A4ocs 0.143 s 4.00 2.55 0 0 0 0 54 44 178 113
4A5-2om 0.770 s 21.56 19.31 0 0 0 0 10 10 207 165
4A5-2om 0.770 s 21.56 19.31 0 0 0 0 0 0 0 0
4A5-2om 0.770 s 21.56 19.31 0 0 0 0 0 0 0 0
11D0 0.390 s 10.92 11.31 0 0 0 0 0 0 0 0
W 13A4ocs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0
Li1013•m 1.390 w 38.92 38.45 0 0 0 0 0 0 0 0
4A5-2om 0.770 w 21.56 45.18 0 0 0 0 0 0 0 0
11D0 ' 0.390 w 10.92 11.31 0 0 0 0 0 0 0 0
C 16B-30ad 0.032 - 0.90 1.68 234 234 210 393 63 63 56 106
F 22A-tpl 0.989 - 27.69 0.00 234 0 0 0 63 7 194 0
6 c)AED scursion -57 -9
Envelopeloss/gain 210 336 671 418
12 a) Infiltration 0 0 102 29
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 2 460 0 0
Appliances/other 2000 0
Subtotal(lines 6 to 13) -210 2796 7731 447
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 210 2796 773 447
15 Duct loads 279/6 1 550/6 56 1537 27% 550/0 208 246
Total room load 266 4333 981 692
Air required(cfm) 3 200 1 1 10 32
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
. _ wr1ghts43Pft- Right-Suite®Universal 2017 17.0.14 RSU08101 2017-Jan-11 12:08:38
Page 3
C:\Users\Quick Caics\Documents\HOLLAND,BREAND.rup Calc=MJ8 Front Door faces: N
+ wrightsoft- Right-M Worksheet Job:
Entire House Date: Jan++,son
By: .
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772466-6799 Fax 772-466-6796 Email:QUICKCALCS(,10L.COM
1 Ran rare MASTER BEDROOM NEW CLST.
2 Exposed well 12.0 it 24.0 ft
3 Room height 9.0 it heat/cool 9.0 ft heat/cool
4 Room dimensions 1.0 x 172.0 it 10.0 x 7.0 ft
5 Room area 172.0 ftz 70.0 ftz
Ty Construction U-value Or HTM Area (ftj Load Area (ftz Load
number (Btuh/WF) (13tuh/ft5 or perimeter (it) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cod Gross N/P/S Heat Cool
6 T 13A4ocs 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0
L-GG 4A5-2on 0.770 n 21.56 19.31 0 0 0 0 0 0 0 0
4A5-2om 0.770 h 21.56 19.31 0 0 0 0 0 0 0 0
VVV���JJJ 13"ocs 0.143 a 4.00 2.55 63 63 252 160 63 63 252 160
11 4A5.2om 0.770 a 21.56 42.10 0 0 0 0 0 0 0 0
4A5.2on 0.770 a 21.56 45.10 0 0 0 0 0 0 0 0
4A5.2on 0.770 a 21.56 45.44 0 0 0 0 0 0 0 0
13A4ocs 0.143 s 4.00 2.65 18 18 72 46 90 90 360 229
4A5-ton 0.770 s 21.56 19.31 0 0 0 0 0 0 0 0
4A5.2om 0.770 s 21.56 19.31 0 0' 0 0 0 0 0 0
4A5-2om 0.770 s 21.56 19.31 0 0 0 0 0 0 0 0
11DO 0.390 s 10.92 11.31 0 0 0 0 0 0 0 0
Val 13AAocs 0.143 w 4.00 2.55 27 27 108 69 63 63 252 160
�G 1013-m 1.390 w 38.92 38.45 0 0 0 0 0 0 0 0
4A5-2on 0.770 w 21.56 45.18 0 0 0 0 0 0 0 0
11DO 0.390 w 10.92 11.31 0 0 0 0 0 0 0 0
C 16B30ad 0.032 - 0.90 1.68 172 172 154 289 70 70 63 118
F 22A tpl 0.989 27.69 0.00 172 12 332 0 70 24 665 0
6 c)AED excursion -21 -15
Envelope loss/gain 919 542 1592 652
12 a) Infiltration 174 49 349 98
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 2 460 0 0
Appliances/other 0 0
Subtotal Qines 6 to.13) 1093 1052 1941 -750
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 1093 1052 1941 750
151 Duct loads 27% 55% 294 678 27°h 65% 522 413
Total mom load 1387 16M 24W 1163
Air regtrired(cfm) 14 75 1 1 25 54
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
-'14- wrirghtsCbft- Right-Suite®Universal 2017 17.0.14 RSU08101 2017-Jan-11 1 P08e 4
CAUserslQuick Calcs%Documents\HOLLAND,BREAND.rup Cale=MJ8 Front Door faces: N
wriglhtsok Right48 Worksheet °b a
oate:
Entire House ,ar,,,,so,r
By:
QUICK CALCS, INC.
317 ST.LUCIE U%,FT.PIERCE,FL 34946 Phone:'772-4W-6799 Fax 772468-6796 Email:QUICKCALCS@,AOL.COM
1 Roan name FOYER BEDROOM 4
2 E4=ed wall' - 8.0 ft 320 ft
3 Room height 9.0 ft heal/cool 9.0 ft heat/cod
4 Room dimensions 1.0 x 206.0,ft 1&0 ,x 10.0 ft
5 Room area 206.0 ft2 150.0 ft2
Ty Constriction U-value Or HTM Area (ftl Load Area (ft2) Load
number (Btuh/ft2-'F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
'Heat 'Cod Gross N/P/S Heat Cod Gross N/P/S Heat Cool
6 yJ 13A40cs 0.143 n 4.00 2-55 0 0 0 0 0 0 0 0
4A5-2om 0.770 n 21.56 . 19.31 •0 0 0 0 0 0 0 0
4A5.2om, 0.770 n 21.56_. 19.31 0 0• 0 0 0 0 0 0
VVVNNN 13A flocs, 0.143 a 4.00 2.55 0 0 0 0 90 75 - 300 191
11 4A5-2on 0.770 'e 21.56„ 4210 0 , 0 0 0 0 0 0 0
4A5-2om 0.770 a 21.56 45.10 0 0 0 0 15 1 323 677
4AS-2om 0.770 a 21.56 45.44. 0 0 0 0 0 0 0 0
W 13A 4ocs 0.143 s 4.00 . 2.55 72 31 125 79 135 .120 480 305
4A5-2am 0.770 s' 21.56 19.31 0 0 0. 0 0 0 0 0
4A5-2om 0.770 s 21.56 19.31 0 0 ,0 .0 0 0 0 0'
4A5-2om 0.770 s 21.56 19.31 0 0 0 0 15 15 323 290
11 DO 0.390 s 10.92 11.31 41 41 446 461 0 0 0 0
13A4ocs 0.143 w 4.00 2.55 0 0 0 0 63 63 252 160
10D-m 1.390 w 38.92 38.45 0 0 0 0 0 0 0 0
4A5 tom 0.770 w. 21.56 .45:18 0 0 0 0 0 - 0'_" 0 0
11DO 0.390 w 10.92 11.31 0 0 0 0 0 0` 0 0
C 16B-30ad'. 0.032 - 0.90 1.68 206 206 185 346 150 150 134 252
F 22A•tpl 0.989 - 27.69 0.00 20.6 8 222 0 150 32 886 0-
6 c)AED emursion -18 -40
Envelope loss/gein 977 669 2700 1835
12 a) Infiltration 116 33 465 131
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants 230 0 0 0 - 0
Appliances/other, 0 0
Subtotal(lines 6 to 13) 1093 901 3165 1966
Less wdemal load 0 0 ' 0 0
Less transfer - 0 0 0 0
Redistribution 0 0 0 0
14 'Subtotal 1093 '901 3165 19M
15 Duct brads 27% 55% 294 496 27% 550/c 851 1081
Total room load 1387 1397 .• 4017 - 3047
Air required(cfm) 14 641, 42 140
Calculations approved'byACCA tomeet.all requirements-of Manual J 8th Ed.
fJ- wrightsoft° 2017-An-11 12:08:38
Right-Suite®Universal 2017 17.0.14 RSU08101 Page 5
�` C:\Users\Quick Calcs\Documents\HOLLAND,BREAND.rup Calc=MJS Front Door faces: N,
+ w�ightsoft• Right-JO Worksheet Job:
Entire House Bate: Jan 11,2017
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-366-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM
1 Room name BEDROOM 3 U\/ING
2 EVosed wall 29.0 ft 10.0 ft
3 Room height 9.0 ft heat/cool 9.0 ft heat/cool
4 Room dimensions 1.0 x 196.0 ft 10.0 .x 10.0 ft
5 Room area 196.0 ft2 100.0 ft2
Ty Construction U-value Or HTM Area (ft� Load Area (ftj Load
number (Btuh/ft'L°F) (BtuWft2) or perimeter (ft) (Btuh) or perimeter (ft). (Btuh)
Heat Cod Gross N/P/S Heat Cod Gross NIP/S Heat Cod
6 %J 13A-4ocs 0.143 n 4.00 2.55 135 112 449 285 90 67 268 171
IL_�( 4A5-2om 0.770 n 21.56 19.31 0 0 0 0 0 0 0 0
4A5-2om 0.770 n 21.56 19.31 23 0 495 443 23 0 495 443
VVVJJJJJJ 13AAocs 0.143 a 4.00 2.55 126 113 452 288 0 0 0 0
11 4A5-2om 0.770 a 21.56 42.10 0 0 0 0 0 0 0 0
4A5-2om 0.770 a 21.56 45.10 0 0 0 0 0 0 0 0
4A5.2om 0.770 a 21.56 45.44 13 1 280 591 0 0 0 0
13AAocs 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0
05.2om. 0.770 s 21.56 19.31 0 0 0 0 0 0 0 0
4A5.2om 0.770 s 21.56 19.31 0 0 0 0 0 0 0 0
4A5.2orn 0.770 s 21.56 19.31 0 0 0 0 0 0 0 0
11D0 0.390 s 10.92 11.31 0 0 0 0 0 0 0 0
13AAocs . w 4. 2. 5 0 0 0 0 0 0 0 0
10D 1
-m .390 390 w 38.92 92 38.45 0 0 0 0 0 0 0 0
4A5-2om 0.770 w 21.56 45.18 0 0 0 0 0 0 0 0
D 11D0 0.390 w 10.92 11.31 0 0 0 0 0 0 0 0
C 1613•30ad 0.032 - 0.90 1.68 196 196 176 329 100 100 90 168
F 22A-tpl 0.989 - 27.69 0.00 196 29 803 0 100 10 277 0
6 c)AED ecursion -41 -16
Envelope losslgain 25M 1895 1130 766
12 a) Infiltration 421 119 145 41
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal pines 6 to 13) 3077 2014 1275 807
Less ekemal load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 3077 2014 1275 807
15 Duct bads 27% 550/0 827 1107 27% 55% 343 443
Total mom load 3904 3121 1618 1250
Air required(cfm) 1 40 144 1 17 58
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
+ wrightsoft' 2017 Jan 11 1
Right-Suite®Universal 2017 17.0.14 RSU08101 Page 6
CAUsers\Quick Calcs\Documents\HOLLAND,BREAND.mp Calc=MJ8 Front Door faces: N
Arrr wrightsoft- RighW@ Worksheet Job:
Entire House Date: Jan 11;2017
QUICK CALCS, INC. By.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772466-6796 Email:QUICKCALCS@AOL.COM
1 Room name BATH 2
2 Exposed wall 8.0 ft
3 Room height 9.0 ft heat/cool
4 Room dimensions 8.0 x 8.0 ft
5 Room area 64.0 ftz
Ty Construction U-value Or HTM Area M Load Are Load
number (Btuh/ft-F) (Btuh/ft) or perimeter (ft) (Btuh) or. perimeter
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Coo!
6 W, 13AAocs 0.143 n 4.00 2:55 0 0 0 0
4A5.2om 0.770 n 21.56 19.31 0 0 0 0
4A5-2om 0.770 n 21.56 19.31 0 0 0 0
13A4ocs 0.143 a 4.00 2.55 72 65 264 .168
11 4A5.2om 0.770 a 21.56 42.10 6 1 129 253
4A5.2om 0.770 a 21.56 45.10 0 0 0 0
4A5.2om 0.770 a 21.56 45.44 0 0 0 0
13A-4ocs 0.143 s 4.00 2.55 0 0 0 0 .
4A5.20m 0.770 s 21.56 19.31 0 0 0 0
4A5.2om 0.770 s 21.56 19.31 0 0 0 0
4A5-2om 0.770 s 21.56 19.31 0 0 0 0
11 ^^ 11DO 0.390 s 10.92 11.31 0 0 0 0
1OD-m 1.390 w 4.92 8.45 0 0 0 0
10D-m 1.390 w �38.82 38.45 0 0 0 0
4A5-tom 0.770 w 21.56 45.18 0 0 0 0
D 11DO 0.390 w 10.92 11.31 0 0 0 0
C 1613-30ad 0.032 - 0.90 1.68 64 64 57 108
F 22A-tpl 0.989 - 27.69 0.00 64 8 222 0
6 c)AED axursion -11
Envelope loss/gain 673 517
12 a) Infiltration 116 33
b) Room ventilation 0 0
13 Internal gains: Occupants @ 230 0 0
Appliances/other 0
Subtotal(lines 6 to 13) 789 550
Less eAemal load 0 0
Less transfer 0 0
Redistribution 0 0
14 Subtotal 789 550
15 Duct bads 270/a 55% 212 302
Total room load 1001 812
Air required(cfm) 10 39
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
wrightsoft" 2017-Jan-11 12:08:38
Right-Suite®Universal 2017 17.0.14 RSU08101
Page 7
��� C:UJsers\Quick Caics\DocumentslHOLLAND,BREAND.rup Calc=MJ8 Front Door faces: N