HomeMy WebLinkAboutWallrath EngineeringDESIGN CRITERIA: APPLICABLE CODES REGULATIONS & STANDARDS 1. THE 2017 FLORIDA BUILDING CODE, SPECIFICALLY CHAPTER 16 STRUCTURAL DESIGN, CHAPTER 20 ALUMINUM & CH. 23 WOOD. 2. AA ASM 35 & SPECIFICATIONS FOR ALUMINUM STRUCTURES, PART 1-A OF THE ALUMINUM DESIGN MANUEL PREPARED BY THE ALUMINUM ASSOCIATION, INC. WASHINGTON D-C. 2005 ED. 3. ASCE 7-10 & SET 7 4. NDS NATIONAL DESIGN SPECIFICATION FOR WOOD. 5. AC1318 CONCRETE REFRENCE MANUAL. WIND LOADS 1. BUILDING OCCUPANCY CATEGORY, PARAGRAPH 1604.5 & TABLE 1604.5: RISK CATEGORY 1. 2. BASIC WIND SPEED, TABLE 1609C, STATE OF FLORIDA DEBRIS REGION & BASIC WIND SPEED, PARAGRAPH 1609.3.1 & TABLE 1609.3.1 EQUIVALENT BASIC WIND SPEED: 150 MPH EXPOSURE CATEGORY, PARAGRAPH 1609.4.3: C 3. WIND LOADS PER FBC TABLE 2002.4 (MWFRS) VULT = 150 MPH & EXPOSURE = C FOR 20 X 20 X 0.013' MESH SCREEN HORIZONTAL PRESSURES ON WINDWARD SURFACES = 43 PSF HORIZONTAL PRESSURES ON LEEWARD SURFACES = 34 PSF VERTICAL PRESSURES ON SCREEN SURFACES = 12 PSF VERTICAL PRESSURES ON SOLID SURFACES = 36 PSF FOR 18 X 14 X 0.013" MESH SCREEN, APPLIED FACTOR = .88 FOR ALLOWABLE STRESS DESIGN, APPLIED FACTOR = •6 FOUNDATION DESIGN FOOTING SIZE EXISTING CONCRETE SLAB. NO ADDITIONAL FOOTING OR FOUNDATION SYSTEM IS REQUIRED BY THE PROPOSED CONSTRUCTION IF A MINIMUM 4" CONCRETE SLAB IS PROVIDED IN SOUND CONDITION, FREE FROM STRUCTURAL CRACKING, SPALLING & OTHER DETERIORATION. EXISTING FOUNDATION/FOOTING UNDER CONCRETE SLAB MINIMUM 8"x&' W/ (1) #5 BAR TO BE VERIFIED BY CONTRACTOR. SEE TYPICAL FOOTING DETAILS FOR NEW FOOTING DESIGN MINIMUM REQUIREMENTS. SPECIFICATIONS THE FOLLOWING SPECIFICATIONS ARE APPLICABLE TO THIS PROJECT: 1. WHERE CONCRETE SPECIFICATIONS ARE REQUIRED, WHETHER IN THE SCREEN ENCLOSURE SCOPE OF NOT, BY ONE OR MORE REGULATORY AGENCY, THE FOLLOWING SPECIFICATIONS ARE APPLICABLE: a. CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING COMPONENTS: i. PORTLAND CEMENT TYPE 1 - ASTM C 150 ii AGGREGATES - LARGE AGGREGATE 3/4 MAX. - ASTM C 33 iii. AIR ENTRAINING +/- 1 %- ASTM C 260 iv. WATER REDUCING AGENT - ASTM C 494 v. CLEAN PORTABLE WATER vi. OTHER ADMIXTURES NOT PERMITTED b. METAL ACCESSORIES SHALL CONFORM TO: i. REINFORCING BARS - ASTM A615, GRADE 60 ii. WELDED WIRE FABRIC - ASTM A185 c. CONCRETE SLUMP AT DISCHARGE CHUTE NOT LESS THAN 3" OR MORE THAN 5". WATER ADDED AFTER BATCHING IS NOT PERMITTED. d. PREPARE & PLACE CONCRETE PER AMERICAN CONCRETE INSTITUTE MANUAL OF STANDARD PRACTICE, PART 1, 2, & 3 INCLUDING HOT WHEATHER RECOMMENDATIONS. e. MOIST CURE OR POLYETHYLENE CURING PERMITTED. f. PRIOR TO PLACING CONCRETE, TREAT THE ENTIRE SUBSURFACE ARE FOR TERMITES IN COMPLIANCE WITH THE FBC. g. CONCRETE SHALL BE PLACED OVER A POLYETHYLENE VAPOR BARRIER. 2. WHEN PAVERS ARE UNDER ALUMINUM MEMBERS, CONTRACTOR SHALL EPDXY TO DECK OR GROUT TO DECK w/3000 PSI GROUT WITH BONDING AGENT 3. WHEN APPLICABLE FOR NEW SLAB ADDITION TO ADJACENT DRILL & EPDXY #5 X 8" REBAR INTO EX. FOUNDATION WITH 1" MIN. HOLE, EMBED 4" MIN W/ NON -SHRINKING SIMPSON EPDXY -TIE (OR EQUAL) 48" O.C.1YP. ALL LOCATIONS 4. WHEN APPLICABLE FOR NEW FOOTER TO EXISTING, DRILL & EPDXY NEW STEEL INTO EX. FOUNDATION WITH 1" MIN. HOLE, EMBED 6" MIN W/ NON -SHRINKING SIMPSON EPDXY -TIE (OR EQUAL) TYP. ALL LOCATIONS 5. MINIMUM CONCRETE STRENGTH 3000 PSI UNLESS OTHERWISE NOTED. ALUMINUM SPECIFICATIONS 1. ALUMINUM EXTRUSIONS SHALL BE 6005 T5 ALLOY UNLESS OTHERWISE NOTED. 2. ALL SELF MATING BEAM SECTIONS ARE TO BE STITCHED WITH # 12 SCREWS 6" FROM ENDS & 24" CENTER TO CENTER. 3. ROOF BRACING SHALL BE A MINIMUM 2X2"X.050". 4. THE MINIMUM NORMAL THICKNESS OF PROTECTOR PANELS (KICKPLATES) SHALL BE AN INDUSTRY STANDARD OF 0.024 INCHES. 5. VINYL AND ACRYLIC PANELS SHALL BE REMOVED WHEN WIND SPEEDS EXCEED 75 MPH PER FBC. 6. SCREEN MATERIAL SHALL BE 18/14 SCREEN UNLESS APPROVED BY FLORIDA ENGINEERING LLC. 5. 1"X2" & 1"X3" NON STRUCTURAL MEMBERS MAY BE USED INTERCHANGEABLY. FASTENER SPECIFICATIONS 1. FASTENERS ARE REQUIRED TO BE SAE GRADE 2 OR BETTER ZINC PLATED. (CONCRETE ANCHORS ARE TO BE TAPCONS OR BETTER, INSTALLED TO MFG. SPECIFICATIONS) 2. IT IS THE OWNERS RESPONSIBILITY TO MAINTAIN THE SCREENS, FASTENERS AND SCREENS TO MANUFACTURING SPECIFICATIONS. 3. WHERE WOOD DECK IS PRESENT USE 1 /4" X 3-1/2" GALV. LAG SCREWS IN LIEU OF MASONRY ANCHORS. UNLESS OTHERWISE SPECIFIED. 4. 1"X2" NON STRUCTURAL MEMBERS ATTACHED TO HOST A. FOR MASONRY/CONCRETE APPLICATION USE GALVANIZED 1 /4" X 2-3/4" TAPCONS OR EQUAL AT 24" O.C. AND 6" FROM ENDS B. FOR WOOD APPLICATION USE # 14 X 2-3/4" WOOD SCREW AT 24" O.C. AND 6" FROM ENDS. C. FOR ALUMINUM APPLICATION USE # 10 X 1-1 /2" SMS OR TEK SCREW AT 24" O.C. AND 6" FROM ENDS D. WHERE 1"X2" INSTALLED THROUGHOUT AN "OPEN VIEW" SPACING SHALL BE REDUCED TO 18" O.C. AND 6" FROM ENDS MASONRY SPECIFICATIONS 1. CONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON TYPE M OR S MORTAR. 2. ALL MORTAR SHALL BE TYPE M OR S. 3. ALL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE MAXIMUM COARSE AGGREGATE SIZE OF 3/8". 4. PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING REINFORCEMENT WHEN GROUT POUR EXCEEDS 5-0" IN HEIGHT. MISCELLANEOUS 1. SCREENED ENCLOSURES CONTAINING SWIMMING POOLS SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF FBC R4501.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS. 2. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME. IF THE EXISTING STRUCTURE IS ONE OF THESE, A SEPERATE 4TH WALL SUPPORT SYSTEM IS SO TO BE ENGINEERED SO THAT NO ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME. 3. DOOR LOCATION MAY BE RELOCATED BY CONTRACTOR IN THE FIELD. 4. WHERE PAVERS ARE UNDER ALUMINUM MEMBERS, CONTRACTOR SHALL EPDXY TO DECK OR GROUT TO DECK w/3000 PSI GROUT WITH BONDING AGENT. 5. INTEGRITY OF EXISTING/ HOST STRUCTURE SHALL NOT BE COMPROMISED WITH THE ATTACHMENT OF THE PROPOSED STRUCTURE. 6. ALL 2X4 & GREATER ARE TO BE 2 x 4 SMB: 2"x4"x0.044"x0.100" UNLESS OTHERWISE INDICATED. RESPONSIBILITIES 1, ALL SITE WORK SHALL BE PERFORMED BY A LISCENED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDANANCES, AND THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES. 2. FOR FASTENERS WHICH ARE NOT VISIBLE AFTER INSTALLATION, THE CONTRACTOR SHALL VERIFY AND ENSURE INSTALLATION HAS BEEN ACCOMPLISHED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS AND IN ACCORDANCE WITH THE ATTACHED DETAILS. 3. FOR "PICTURE WINDOW" MODIFICATION TO EXISTING SCREEN ENCLOSURES, ALL OTHER "EXISTING SCREEN ENCLOSURE" FEATURES ARE TO MEET THE TYPICAL DETAILS AS PROVIDED IN THESE DETAILS. CONTRACTOR IS TO VERIFY & ASSURE EXISTING SCREEN ENCLOSURE IS STRUCTUALLY SOUND. ALUMINUM MEMBERS DIMENSIONS HOLLOW SECTIONS 2x2:2"x2"x0.050" 2x3:7'x3'x0.05G' 2x4:2"x4"x0.059' 2x5:2"x5"x0.05G' OPEN BACK SECTIONS 1 x2: 1"x2"x0.044" 1 x3: 1"x3'x0.045' SNAP SECTIONS 2 x 2 SNAP: 7'x 2" x 0.045" 2 x 3 SNAP: 2" x 3'x 0.059' 2 x 4 SNAP: 2" x 4" x 0.045" SELF MATING (SMB) 2 x 4 SMB: 2" x 4" x 0.046" x 0. 100" 2x5SMB: 7'x5"x0.05G'x0.116" 2x6SMB: 2"x6"x0.050"x0.120" 2x7SMB: 2"x7"x0.055"x0.120" 2x8SMB: 2"x8"x0.077'x0.224" 2x9SMB: 2"x9"x0.072"x0.224" 2x9(H) SMB: 2"x9"x0.082"x0.306" 2 x 10 SMB: 2" x 10" x 0.092" x 0.374" DETAIL A c a� 3Eomo w 7@a) mbgmEm-0 N 0 O & V N N R N'y OQ .c II 0 O) � 0 O 0 EmNoo�mU c c -0 a) m n-o 2)o = a) -0 0)a1 -N n y yccc'p.ca�a�i O O •c m O ,n La- F- ) `aunuiiun,,," GUs0 ,, �¢g: F _oy * No. 60102 * ? •: STATE OF W c ' 0 -• tV - %;��t`S Ft %„S/ON Al-. Digitally signed by Craig E Gunderson Date: 2020.11.12' 14:39:22-05'00' U � J 0 N U-) z z_ Q E 0 = 0 w p U W J 0 co cn W<LL.LO,_ J m Z s- N W (Ma) rr�� 0 WQ_jvN Q _� C) F- U 0(c)� 0 J 12 U j J I J z W W Q UU it Of O Z Q H d w > z O O a w U U 04 L0 M O 04 DESIGN DATE: 11/11/2020 1 REVISION 1: DATE REVISION 2: DATE PAGE: DRAWN BY: TCP SCALE: NTS Digitally signed LLJ by Craig E No. 601.2 Gunderson STATE OF Date: CZ, Ou co co CO Z! __L LLJ 2X9SMB C.B. DESIGN DATE: 11/11/2020 REVISION 1: DATE REVISION 2: DATE PAGE . DRAWN BY: TCP SCALE: NTS OSODDED GRADE 12„ .% MIN. a BRICK PAVER DECK OPTION (2) #5 BAR CONTINUOUS FOOTING NOTES 1. PROVIDE 1-1/2' COVERAGE TOP, SIDES, BOTTOM AND 1" BETWEEN ADJACENT REBAR LAPS. 2. PROVIDE MIN. 3" COVERAGE OF REBAR FOR ALL CONCRETE IN CONTACT WITH THE EARTH. 3. FOOTING CONCRETE SHALL BE MIN. 3000 PSI AT 28 DAYS 4. FOOTING REINFORCEMENT SHALL BE MIN. GRADE 60 5. PROVIDE POSITIVE DRAINAGE AWAY FROM STRUCTURE TO CITY / CO. REQUIREMENTS 6. PROVIDE 2500 PSF BEARING (TYPICAL) UNDER FOUNDATION 7. SEE GENERAL NOTES FOR TYING INTO EXISTING FOUNDATIONS 8. SEE GENERAL NOTES FOR ADDITIONAL CONCRETE INFORMATION & SPECS. 12"x12" RIBBON FOOTING SCALE: NTS HOUSE WALL i- 14I-0il 291 _011 CONC. PLAN NTS T C Digitally signed ����_� .G�.Gv"°F, `m U. ��cENSFRso byCraig E I o.2sa `,�P: No.60102 - Ema .Gunderson t N N V N STATE OF - :4r Date: smwcnOc �_ �,�0 o• ORi Fs ' 2020.11.12 �N =ac-6:sa3 �G ",","/ONAL �*.`. �o`E @ � = 14:40:00-05'00' d-aNCD t9 ON-O CD O -N O OU50 .00 O co f n v Z zoo Q E 0 O U W -J O co J m �, z r N o~�H-cep W M N Z 0 a' WQW < Q = C) F— U cj� F- o�w O J d ri LL N 00 t- o M o' w U a v CV M O N O z F-- U W O ry CL U U J } � Q Z m W H W W Of W LJL } W w QH W Z o a zU J JOD� d W d z O O G U a DESIGN DATE: 11/11/2020 REVISION 1: 11/11/2020 REVISION 2: 11/11/2020 PAGE: DRAWN BY: TCP �� SCALE: NTS p @ m ` Digitally N C C'p'OO `...... p'i `—' w — -c a� 0GUN _ F'4's°'-' signed b Craig FLASHING 'HORIZONTAL OR SLOPED U 07 � � l6 y ``�G� GEN �•., .�7•` g y g L (INTERNAL) (2) #IOx3' SMS INTO SCREW No, 60102 = -.E Gunderson I'x2' FASTEN TO CO BOSSES FOR EDGE MEMBER E4VE RAILS I/2' SMS, FASTEN TO W (p m G STATE OF Lp; Date: EAVE RAILS ABOVE W/ #I0XI-1/2' SMS 0 N 0 E 24' O.C. AND 6' FROM END. '0 03 _ TABLE 'D' ° f0c o c 'o) w -0 =3 U %FSS " ��.° 2020.1 1 ,1 2 cc o - o ALUMINUM INTERNAL OR EXTERNAL 0 0 O 0 OJ c14 39 38 0 /,�x'q�nn u�pN x i -05 00 t BEAM OTY EACH SIDE/SIZE 2 x 3 4/12 2 x 4 5/12 2 x 5 5/12 2 x 6 6/12 2 x 7 7/12 2 x 8 8/14 2 x 9 9/14 2 x 10 9/14 CO N PER ° 0 RECEIVING CHANNEL w/(4) #IOx.75 •- W EDGE MEMBER o ° INTO GIRT OR PURLIN & (2) #14x.75' { y C C u1 U OR PURLIN o ° INTO BEAM OR UPRIGHT 0.062 ANGLE ;� O) 3 -N Q 0 0 ° CLIPS MAYBE USED ♦- y C9 U U r N ° (4) #10xZ' SMS INTO o SCREW BOSSES BEAM PER PLAN NOTCHED TO RECEIVE (2) #I0x2' I N 00 1- O Ur) COLUMN WITHIN INTO BEAM MEMBER - �- ---- -- CD -` OR PURLIN ---- co --------T SMS. (EACH SIDE) BEAM BEAM BRACE I R) I— m ~ OTY PER TABLED 0.0625' 6063-76 FLAT PLATE w/(8) #IOx314' SMS• MIN. 112' �✓ EDGE DISTANCE. PLATE MAY BE Z 0 O Q NOTCH PROFILE MAY VARY i TO PERMIT CORRECT # SHE INSTALL BRACE I---_�=1� FASTENED INTERtJALLY TO BP,ACE TO CORNER FRIGHT. BEAM -SNAP, SELF MATING, OR HOLLOW'ry PURLIN MEMBER i U ! P ANS PURLIN O O LUM L MAINTAIN MIN. OF 5/8' SEPERATION , 1 W LL U-) .c FROM EDGE OF BEAM SMS O.C. TYP. L- LI� r� Q) DETAIL "E" - UPRIGHT TO BEAM j (� ~ t— ~cM _ CONNECTION SCALE: N.T.S. DETAIL "D" - ROOF BRACING DETAIL "C" - GIRT OR PURLIN TO BEAM z O 0) CONNECTION SCALE: N.T.S. OR POST DETAIL SCALE: N.T.S. W Q � a) Qom¢ NOTE: IF PAVERS ARE PRESENT.CONCRETE ANCHORS SHALL PENETRATE INTO FOOTING 2-I/4' MIN. (TYP.) NOTE: WHEN FASTENING TO WOOD USE 114' GALV. { LAG SCREW IN LIEU OF ( CONC. ANCHORS AND (ENSURE PENETRATION I MIN 2-114' INTO STRUCTURAL FRAMING BENEATH (TYPJ 1/4' DIA, TAPCON SCHEDULE UPRIGHT I OTY. TAPCON/ OTY. #12 SMS E/S 2X3 (I) 1/4" TAPCON/ (4) #12 2X4 (2) 1/4" TAPCON/ (4) #12 2X5 (2) I!4" TAPCON/ (4) #12 j 2X6 0) 1/4" TAPCON/ (6) #12 2X7 (3) 1/4" TAPCON/ (6) #12 2X8 (4) 1/4" TAPCON/ (8) #12 2X9 (4} I/4" TAPCON/ (8) #12 2X10 (5) 1/4" TAPCON/ (10) #12 3/8' DIA. TAPCON SCHEDULE UPRIGHT I OTY. TAPCON/ OTY. #12 SMS E/S 2X3 ;(U 3/8" TAPCON/ (4) #12 2X4 1(2) 3/8" TAPCON/ (4) #12 j 2X5 (2) 3/8" TAPCON/ (4) #12 2X6 ;(2) 3/8" TAPCON/ (6) #12 2X7 (2) 3/8" TAPCON/ (6) #12 1 2X8 (3) 3/8" TAPCON/ (6) #12 2X9 2X10 i(3) 3/8" TAPCON/ (6) #12 j(4) 3/8" TAPCON/ (8) #12 :ALL MEMBERS PER PLAN PAGE 2 2'x2'x.063' - DIM. TO MATCH PURLIN ! N MEMBERS VARY PER PLAN PAGE 2 ! SIZE RECEIVING CHANNEL O LL+ O LO (2) #12 SMS INTERNAL TO EAVE RAIL (3) #12 EACH SIDE INTO PURLIN 0r d' - i 1 FASTEN TOP OF HEADER TO INTERSECTING i 1 0 jI L MEMBER w1(2) #10 SMS wri' ; O PENETRATION INTO SCREW BOSS Of : I EAVE RAIL -SEE PLAN ° 1, MEMBER - TYP. BOTH SIDES I I h'( Ix? OPEN ..BACKI { t— SCHEDULE BASED ON 2-1/4' MIN. SCHEDULE BASED ON 2-114' MIN. " J --HT CONCRETE ANCHOR EMBEDMENT CONCRETE ANCHOR EMBEDMENT DOOR UAMB 'i ' W PER PLAN SELF -MATING OR Q) #IOx2' SMS THRU Ix2 IWTO { 1` V8'x2'x2'x ANGLE SNAP SECTION TYP. i EAVE RAIL EACH SIDE OF COLUMN I O ! 5032 H-32 ANGLE it PER PL4.N i i (2) - #12 SMS INTO COLUMN t 1 f I ! 02' 0.8. BASE PLATE-TYP. I/4' MASONRY ANCHOR EACH ANGLE - EACH SIDE COL. I i ! ° 0 1-114' MIN. CONIC. 2-1/4' MIN. CONC_ o o I FASTEN HEADER wl(2) #IOx3' 1 I ANCHOR EMBEDMENT i1 ( I ANCHOR EMBEDMENT INTO SCREW BOSS OF HEADER I DETAIL "G" - SLOPED PURLIN j •1 z MIN ANCHOR SPACING j CONNECTION SCALE: N.T.S. • ra• { j ALTERNATE HEADER CONNECTION • ` I! ,j WHEN Z48AR IS USED - FASTEN ! e WHEN GREATER THAN 2x4 I 7-BAR TO COL/HEADER AT EACH .' t "�° • ° - FRIGHT IS USED SEE CORNER AND 18' O/C 1-1'2'x 1116' PLATE ` a < TAPCON SCHEDULE ABOVE # (TOP OR BOTTOM) U2) 12x1' SMS 3000 PSI CONIC. SLAB' FTG. I' SPACING { bxb-IOxiO WWM SIDE VIEW II 1 5 ( i ! _J I >- OR FIBERMESH 1 i 2'x2' EDGE BEAM - f ALTERNATE BASE PLATE CONNECTION I —I ATTACH MEMBER 70 BASE PLATE I 1 I m ! I� (INTERNAL) w1(2) #10x2' S11S 1/4' MASONRY ANCHOR �� �t�P� I W I•j,J AT EACH ANGLE Z - #12 SMS I .i (2) #10x3' SMS I W LL I ' INTO SCREW BOSSES ATTACH BASE PLATE TO MEMBER ? ! V4' TAPCON XL (RED HEAD MFG. OR EOUAU I �I I CONNECTING EDGE } 2 @ Ix2 BASE ,I i' wOSS OF BA SMS INTO SCREW ( BEAM TO PURLIN I'x2' FASTENED TO COLUMN (0 E-- 2 @ SLAB (BEYOND) �� I BOSS OF BASE PLATE I' w/(2) #I0xI-I/2' SMS INTO Of w W Q C) SCREW BOSSES FOR SMS ry Z { OR SNAP COLUMN Q z p J ��`,a' P i U O F- d. J Px2'BASE PLATE ANCHORED < ° 1 Q I'x2' SNAP U lC3 Q �' ° TO CONIC w/ 1/4' MASONRY ° a ° , ° ° • w Q- • ANCHOR b' MAX EACH SIDE ° o °� NOTCH COLUMN AS REO'D. Z O < ° < OF POST AND 24' O.C. MAX • ° . • • a ° ° , A` ° a �A COLUMN PER PLAN 0 U. 6" 3000 PSI CONC. ° ° DESIGN DATE: 11/11/2020 SLAB/ FTG. I/4' TAPCON (RED HEAD MFG. OR EGUAL) WITHIN 6' OF COLUMN REVISION 1: DATE 6x6-I0 x10 WWM FRONT VIEW 6 24' O.C. MAX. 1-1/4' PENETRATION INTO UNDERLYING FOOTING OR FIBERMESH ALTERNATE DETAIL "G" SLOPED REVISION 2: DATE PAGE DETAIL "B" - 2"W' OR LARGER SELF MATING DETAIL "F" - DOOR JAMB & HEADER PURLIN CONNECTION SCALE: N.T.S. DRAWN BY: TCP UPRIGHT TO DECK DETAILS SCALE: N.T.S. CONNECTION SCALE: N.T.S. SCALE: NITS GIRT FASTENED INTERNALLY AT EACH END w/ #10x1.5' EACH SCREW GROOVE. FASTEN TO BEAM w1 2x2x_125 ANGLE (2) 912 SMS INTO BEAM 8 (2) 910XL5 THRU ANGLE INTO GUTTER WHERE NO GIRT IS PRESENT, ATTACH ANGLE DIRECTLY TO GUTTER -� 2'x2'xl/8' ANGLE w1(2) #12 SMS EACH LEG BEAM CLOSE BOTTOM OF BEAM WHEN TRIMMED .041. RECEIVING CHANNEL, FASTEN w/(2) #12 SMS EACH SIDE OF BEAM - GIRT #10 SMS WITHIN 6' OF BEAM 8 24' O.C. 2x2X1/8' ANGLE EA. SIDE OF BEAM w/(2) #12 SMS EACH LEG EACH SIDI FOR BEAMS ABOVE 2x8 INSTALL GUTTER BRACE AT MIDPOINT BETWEEN BEAMS 8 INCLUDE 2' GUTTER BRACE AT EACH BEAM LOCATION I o FOR GUTTER TO FASCIA: (2) #12 SMS (U #14 @ 18' O.C. o FOR GUTTER BRACE/ STRAP: ° I (2) #14 EA. STRAP F0 o SEE TOP VIEW OR BEAM OVER Zx5 .044 RECEIVING CHANNEL FASTEN TO STRUCTURAL GUTTER INTERNALLY w/(2) #12 SMS ALTERNATELY 2x2XI18- ANGLE BELOW GIRT, (2) #14 SMS INTO BEAM 8 (2) #12 SMS INTO STRUCTURAL GUTTER SIDE VIEW TOP VIEW DETAIL "H" BEAM TO GUTTER CONNECTION SCALE: N.T.S. FASTEN GUTTER TO FASCIA w/ 9102' WOOD SCREW 18' O.C. (2) #12 SMS (2) #14X2' WOOD SCREW FASCIA (2'x6' MIN. EXISTING) STRUCTURAL GUTTER '' I-F o c o- o o f FJ ° o ° ` c o I I( F o ° o I F \\ c ° o c - o ° o ° 1. I o 0 F F \\ o 0 0 3/16'-5052-H32 GUSSET \ 1F INTERNAL OR EXTERNAL \\° 8' INTO EA. SIDE TYP. F (2XI0SMB ILLUSTRATED) NOTE F INSTALL FASTENERS ALONG PERIMETER OF GUSSET -BEAM JOINT 3/8' MIN, FROM EDGE. FASTENERS MAY BE STAGGERED TO INSURE PROPER OUANTITY PER TABLE B-I FASTENER PATTERN MAY APPEAR DIFFERENT FROM ILLUSTRATION. MAINTAIN 112'SEPARATION BETWEEN FASTENERS. MAINTAIN 3/8' MIN, FASTENER SEPARATION FROM BEAM JOINT OR EDGE OF BEAM LAP FASTENERS MAY BE EVENLY SPACED AROUND EDGE OF GUSSET WITHIN 3/8" OF BEAM JOINT. FASTENERS MAY BE STAGGERED TO INSURE PROPER OUANTITY PER TABLE B-I TABLE B-I Kt SIZE COL. TO BECM 0TY 5M5/ SIDE OF COL. I BEAM TO i BEC ` Oit' .,t�5) FACE/SIDE 2 x 4 (5) #12 i (9) #12 2 x 5 (5) #12 (9) #12 2 x 6 (7) #12 ( (9) #12 2 x 7 (10) #12 (10) #12 2 x 8 (12) #12 (14) #12 2 x 9 00 #14 (14) #14 2 x 10 (16) #14 (I5) #14 DETAIL "K" GUSSET CONNECTION SCALE: N.T.S. .050' GUTTER STIFFNER FASTEN TO FASIA w(2) #14x2' WOOD SCREW FASTEN TO GUTTER w(2) #12 SMS — GUTTER GUTTER WHEN BEAM 8 PURLIN HIT ON CORNER - FASTEN OUTSIDE OF BEAM 6 PURLIN w/ Ii8'x2'xZ' ANGLE 8 (4) 912 SMS EACH LEG FASTEN INSIDE CORNER (BEAM TO PURLIN) w! 118'x2'x2' ANGLE w/(2) #12 SMS INTO EA. MEMBER (BEAM 8 PURLIN) (9) #10):2' DETAIL "M" BEAM & PURLIN TO GUTTER CONNECTION SCALE: N.T.S. 1/8' PLATE ON 45* ANG( OR 118'x2'X2' ANGLE w1( #12 SMS INTO EACH INTERSECTING MEMBER (2) #14 WOOD SCREWS (2) #12 SMS INTO FASCIA I PERIMETE( FRAMING 2x2x118' ANGLE wi(2) GIRT .12 SMS EA. LEG c c DETAIL "1-2" CABLE CONNECTION SMB AT CORNER SCALE: N.T.S. o ° ( ° A C co >. 'a @ c:Digitally signed rnit ��m Om Craig E �•�by �U �- = �: No.60102 _ -:Gunderson ° ` 3 *0 y N - - �w Date: � a4) .o co LL! in .ap � E m I'Da m y. n ��� ; p'•. STATE OF : a 1L , .. CORfOP': �� 2020.11.12 _.0�m E m 0 02, 9 ,Fss..... �,�, �ONAt-�oo` 6 'O N N -a m 2 """w"11 14:39:45-05'00' 0)'0 0) 0) .N .N ... 0C C C '- C C m� m O - f-.N(D m U U... N -- - 1/8' STAINLESS STEEL 118'x2'):4' STRAP STRUCTURAL GUTTER MIN. BRAIDED CABLE (2) #12 SMS INTO BEAM SIDE VIEW 60` 60` MAX. (2) 412 SMS INTO GUTTER I ( GIRT (2) GUTTER BRACES /�j/ ! EACH w1(2) #12 SMS FASCIA i INTO GUTTER 8 (2) #14 x 2' 4' MIN. SLAB WOOD SCREWS INTO FASCIA w/FOOTING 3t8' DIA x 3' EMBED CONC. SCREW ANCHOR 2x2xU8' ANGLE w/(2) (iT o �« (TAPCON OR EOUAU #12 SMS EA. LEG 3000 PSI CONC. 6x6-IOx.10 i �O�'MN' X. V4YJM OR FIBERMESH SMB Iz, ! V I 1 I/8'xZ'x4' STRAP ' (2) #12 SMS INTO BEAM GIRT 12) #12 SMS INTO GUTTER STRUCTURAL GUTTER TOP VIEW DETAIL "L" CORNER GUTTER CONNECTION SCALE: N.T.S. 4' MIN. SLAB / wlF00TING J 1.5'x5.5' ALUM. STRAP w1(2) 1/4' DIA. x 2-114' MASONRY ANCHOR (TAPCON OR EOUAL) DETAIL '14' CABLE CONNECTION AT FOUNDATION SCALE: N.T.S. (EBOLT FOR 4BLE TENSION 118' STAINLESS STEEL BRAIDED CABLE 3000 PSI CONC. 6x6-10x10 WWM OR FIBERMESH C) LO J M co 1— co zzo 0 — rY — 0 ry p U W j � 0) z � z_ LL ' . H V z oCc' W `— ern' Q 0 �—{�� U ry 0 0 _j�^ LL L U J J � Q z m W F- W W NN Of IJU cr W o z OQ zU J W _j 00 f (� ^ Z 0 0 W. U CL DESIGN DATE: 11/11/2020 REVISION 1: DATE REVISION 2: DATE PAGE: /� 4 DRAWN BY: TCP SCALE: NTS 3116" 5052-1-132 GUSSET- - #14 SMS @ 1 1/4" O.C. 2" X PURLINS ATTACH TO BEAM WITH MIN (4) #10 X 1 1/2" SMS PLACE WASHER UNDER SCREW IN GUSSET CORNER o o c o c c 0 0 0 0 0 0 0 - 1 1/4" (TYPICAL) �2 31 5' 6 519 8' NOTES: 1. GUSSET DIMENSION ARE MINIMUM (2) REQ'D (1) EA SIDE OF BEAM - MAYBE INTERNAL OR EXTERNAL 2- AS BEAM SIZE CHANGES, ADD OR SUBTRACT SCREWS TO MAINTAIN 1-114" C/C SPACING 3. GUSSET LENGTHS REMAIN CONSTANT WIDTHS CHANGE TO MATCH BEAM SIZE. 2"X2"X1/8" ANGLE X 4" LONG PROVIDE #14 X 1" INTO EACH MEMBER AS INDICATED BELOW PROVIDE INTERIOR ANGLE ABOVE AND BELOW CHAIRRAIL EXTERIOR PLATE CORNER POST /- EAVE RAIL 1"x2"O.B. PATIO SECTION 3" x 3" x 0,050" MIN., 6063-T6 ALLOY PLATE DR STRONGER (ONE SIDE) WITH (3) - #12 x 3/4" S.M.S. EACH SIDE AS SHOWN (3/8" MIN. PLATE EDGE DISTANCE & C-C FASTENER SPACING) X2X0.0 K-BRACE LATERAL "K"-BRACING CONNECTION DETAILS GUSSET PLATE PER E-SERIES PURLIN 3" x 2" x 0.050" MIN., 6063-T6 ALLOY PLATE DR STRONGER (ONE SIDE) (3) - #12 x 3/4" S.M.S., EACH SIDE AS SHOWN (1/2" MIN. PLATE EDGE DISTANCE & C-C FASTENER SPACING) 1" X 2" O.B. FASTENED TO CORNER POST W/ #12 X 1 1/2" SMS AT 6" FROM ANGLE — TOP & BOTTOM RAILS TYPICALLY @ 24" O.0 1" INTO EACH I 1/8" X 2" X 2" EXTRUDE ANGLE 5052 DICATED BELOW H-32 ALLOY EA CORNER W/ (2) #14 X 2" T I SMS INTO POST & (1) 3/8" DIA CORNER POST CONCRETE SCREW ANCHOR INTO j CONCRETE 6" 1 (2) #10 X 1 1/2" SMS THRU SCREW BOSSES z va Mai CONC NCHOR E BEDMENT SLAB/FOOTING NOTES: SEE PLAN 1, CONNECTION DETAIL AT EAVE RAIL SIMILAR SELF MATING BEAM CONTRACTOR TO INSTALL (2) #14 X 2" SMS THRU BRACE INTO BEAM THRU GUSSET PLATE SIDE VIEW CORNER K-BRACE DETAIL SCALE: N.T.S. (4) #14 X 3l4" SMS INTO POST 1" X 2" BASE PLATE ANCHORED TO CONC Wl 1/4" CONCRETE SCREW ANCHOR (MIN. 1 1/4" EMBED) 6" MAX EACH SIDE OF POST AND 24" O.C. MAX T C co C Digitally signed "-� °�.:�ENSFRso, by Craig E NU m S G•p > V: 2 *: No.60102 -• * `:.Gunderson ZQ C m 22 - 0- 0 6 UU fn 'UO -m N * - _ -Date: •-. STATE OF .Q ,f,�a�a o " N rn y to c ME �>�` t 'oF L�,. sso 20201112 c o E m 1 2 -6 c ��.�.�c.0 NAu,,..++` r r 14:39:52-0500 - 67'a CDA) fN C C C •fl. C U L 2)7 Vl O O�- {—N (7 U U ...• N 2„ - r I CORNER POST W/ 1" X 2" @ ;, —,._ BACKSIDE 3/8" X LENGTH AS REQUIRED FOR 2 1/4" EMBED CONCRETE SCREW ANCHOR INTO CONCRETE FRONT VIEW DETAIL #2 CP-1 CORNER POST TO CONCRETE DETAIL A 4 SCALE: NTS CORNER POST {f j 6" x 5" x 0.050" COLUMN 6063-T6 ALLOY PLATE j K-BRACE (ONE SIDE) OR STRONGER 2 x 2 x 0.093 i BRACE (TYP.) i I K-BRACE I x2x0.093 BRACE (TY . 2 x 3 x 0.070 CHAIR RAIL O 0 0 O Oi O _ --- ____ _ O p i O I O O 1 O GIRT (CHAIR RAIL) K-BRACE / I O O O l O �I 318" 0 CONCRETE ANCHOR (2 PLATES) FOUNDATION IN LIEU OF TYP. 1/4" 0 CONCRETE SCREWS FOR CORNER COLUMN LATERAL "K"-BRACING CONNECTION DETAILS L I 2x2x0.093 BRACE (TYP.) (11 TOTAL) -#12 x 3/4" S.M.S. AS SHOWN (1/2" MIN. PLATE EDGE DISTANCE & LATERAL "K"-BRACING C-C FASTENER SPACING) CONNECTION DETAILS J C) � ( t1 F— (Y) ZZ Zip Q E 0 13� O V WJOcoa) W<C J � .c Z ryUJ N V co �— Z�O- W-Q� d Q = E- U L.L r I- 0(0W O J r- d' a- N L0 M O N w U U J >- J Q Z m W E-- w W -j H co W W O o �ZU J Z Q O V �00� W ' >�>IIdlj•Q > 0- Z O O U Tf a_ DESIGNDATE: 11/11/2020 REVISION 1: DATE REVISION 2: DATE PAGE: G J DRAWN BY: TCP SCALE: NTS (3) 1/4" DIA. MACHINE BOLTS w/ 3/4" DIA. WASHERS THRU CARRIER BEAM & POST ® CARRIER BEAM 0 1 11106111 VARIES I"X2" MEMBER FOR SCREENING HORIZONTAL BEAM ON ITS SIDE (IF REQUIRED) 7k7' FASTENED TO CARRIER BEAM w/(2) # I0x1-1 /7' SMS INTO SCREW BOSSES EACH END 2"x7'xO.125" I 2'FOR SINGLE RECEIVING CHANNEL HORIZONTAL BEAM OR ANGLE EACH SIDE 4" FOR DOUBLE HORIZONTAL (6) # 10x0.75' SMS BEAM OR 4"x4" EACH SIDE 6" FOR TRIPLE � HORIZONTAL BEAM OR 6X6 (12) #l0x0.75"SMS 2 ROWS OF (6) FOR RECEIVING CHANNEL OR (6) EACH ANGLE CARRIER BEAM TO POST DETAIL SCALE: NTS CARRIER BEAM N 1"x2"MEMBER O FOR SCREENING- 0 # I Ox 1-1 /7' SMS @ 24" O.C. MAX CONNECTING TO 1"x7' CARRIER BEAM # 10x1-I /7' SMS @ 24" O.C. MAX CONNECTING - TO i"x7' POST (2) 3/8" DIA. EXPANSION BOLTS SEE NOTE # 1 THIS PAGE FORBOLTPLACEMENT (2) 1 /4" DIA. MACHINE BOLTS w/ WASHERS i ! (- 2'FROM EDGE 7FROM EDGES (; OF SLAB/ FIG. OF SLAB/ FIG. V( 1 ! TOP VIEW (2) 1 /4- DIA. MACHINE BOLTS w/ WASHERS 3"6" POST (SEE PAGE-2 (2) 3/8" DIA. EXPANSION BOLTS FOR SIZE) SEE NOTE # 1 THIS PAGE FOR BOLT PLACEMENT I �'-- 3"x3"x0.I25 ANGLE • a o ID 3000 PSI CONC. SLAB/ FIG. FRONT VIEW 6x6-10x10 WWM OR FIBERMESH 3"x3" POST CONNECTION DETAIL SCALE: NTS 7'xnO.125" RECEIVING CHANNEL ROOF BEAM (SLOPED OR FLAT) (NOTE USE SIMILAR DETAIL FOR NOTCHED UPRIGHT CONNECTION TO CARRIER BEAM 3/4" SMS SEE TABLE FOR SCREW SIZE/ QUANTITY (TYP. EACH SIDE) (2) ROWS OF 3/4" SMS SEE TABLE FOR SCREW SIZE/ QUANTITY NOTE: FOR DOUBLE OR TRIBLE CARRIER BEAM, OUTSIDE WEBS SHALL OVERLAP 4x4 POST OR NOTCH POST AS ABOVE FOR 6x6 POST. ALL CASES, CONNECT USING MACHINE BOLTS DECRIBED ABOVE. ROOF BEAM TO CARRIER BEAM CONNECTION DETAIL SCALE: NTS 7'x SMB (SEE-PAGE-2 (2) 3/8" DIA. EXPANSION BOLTS FOR SIZE) SEE NOTE # 1 THIS PAGE FOR BOLT PLACEMENT (2) 1 /4" DIA. MACHINE --', BOLTS w/ WASHERS 1 n 7' FROM EDGE FROM EDGE u OF SLAB/ FIG. E OF SLAB/ FIG. 3'k3" POST (SEE PAGE-2 FOR SIZE) (2) 1 /4" DIA. MACHINE BOLTS w/ WASHERS (2 TOTAL PER POST/SMB CONNECTION) 12) 3/8" DIA. EXPANSION BOLTS SEE NOTE # I THIS PAGE - FOR BOLT PLACEMENT TOP VIEW STITCH w/(2) # 12x3/4" SMS @ 12"O.C. 7'xSMB (SEE_ PAGE-2 FOR SIZE) 356"W.125" ANGLE 3000 PSI CONC. SLAB/ FIG. FRONT VIEW 6x6-1Ox10 WWM OR FIBERMESH 3"x3" POST wI 2x SMB CONNECTION DETAIL SCALE: NTS NOTES: 1.3x3 POST TO HAVE 3/8" RED HEAD - TRUBOLT WEDGE ANCHORS (STAINLESS STEEL, PROVIDE MINIMUM 2" FROM EDGE OF SLAB AND PROVIDE MINIMUM 2" SPACING TO ANY OTHER CONNECTOR. SEE MFG. NOTES FOR INSTALLATION REQUIREMENTS. THREADED ROD REQUIRES 3" MINIMUM EDGE DISTANCE. 2.4x4 POST TO HAVE 1/2" RED HEAD - TRUBOLT WEDGE ANCHORS (STAINLESS STEEL, PROVIDE MINIMUM 3-3/4" FROM EDGE OF SLAB AND PROVIDE MINIMUM 3-3/4" SPACING TO ANY OTHER CONNECTOR. SEE MFG. NOTES FOR INSTALLATION REQUIREMENTS. 3. WHERE PAVERS ARE PRESENT ANCHOR LENGTH SHALL BE INCREASED BY THICKNESS OF PAVER NOT TO EXCEED 2-1/2" FOR PAVER THICKNESS MORE THAN 2-1/2" SPECIFICATIONS SHALL BE REQUIRED. PAVERS SHALL BE BONDED TO UNDERLYING CONCRETE FOUNDATION. ROOF BEAM TO C.B. W/ REC. CHANNEL TABLE BEAM SIZE QUANTITY/ SIZE LEG TO BEAM E/S QUANTITY/SIZE TO BEAM. INTERNAL 2 x 4 (4) # 12 OR (2) # 16 (8) # 12 OR (3) # 16 2 x 5 (5) # 12 OR (3) # 16 (10) # 12 OR (3) # 16 2 x 6 (5) # 12 OR (3) # 16 (10) # 12 OR (4) # 16 2 x 7 (6) # 14 OR (4) # 16 I(12)#14OR(4)#16 2x8 (7) # 14 OR (4) # 16 (12)#14OR(6)#16 2 x 9 (8) # 14 OR (5) # 16 114) # 14 OR (6) # i b 2 x 10 (9) # 14 OR (6) # 16 (14) # 12 OR p) # 16 (2) 1/2" DIA. EXFANSION BOLTS SEE NOTF #2 THI` " FOR BOLT PLA( 3-3/4" FROM OF SLAB/ FIG T C � m O ':3 M 0 Digitally signe Uj 3 p o c c � a zy: by Craig E a,U m c-0 > *r No.60,02 .i ? Gunderson c c E co -0 c N UO N vi 76 L4 ; �'•. STATE OF :'t Date: (3) 1/4"DIA.MACHINEBOLTS 3/4" DIA. WASHERS THRU .0 -6 m E � w )'- N p -0 '% �`s••.<OR10?'�G��� . �O'io 1 1.1 �:. L 1 I w! POST CARRIER BEAM POST � c 0),,, tr O E 1602 m CDrn ,, `SJON �: �� "'1....„„ O 14:40:08 -05 01 'o a� m w -0 o .-aN tq C C C -Q C lot U t 0) O'Vl 0 0 TOP VIEW ®C CARRIER BEAM 0 1t_ I (31 1/4" DIA MACHINE BOLTS POST w/ 3/4" DIA, WASHERS THRU CARRIER BEAM & POST (3) 1 /4" DIA. MACHINE BOLTS w/ 3/4" DIA. WASHERS THRU CARRIER BEAM & POST CARRIER BEAM (3) 1/4-DIA. MACHINE BOLTS w/ 3/4" DIA. WASHERS THRU CARRIER BEAM & POST FRONT VIEW CORNER CARRIER BEAM CONNECTION DETAIL SCALE: NTS 4" DIA. MACHINE 14) 3/8"x4" TAPCON THRU S w/ WASHERS BOTTOM LEG OF ANGLE INTO CONC. (3) 1 /4" DIA. MACHINE BOLTS w/ WASHERS 3-3/4" FROM EDGE OF SLAB/ FIG. 3-3/4" FROM EDGE OF SLAB/ FIG. TOP VIEW J O Lo co Ur F— co zzo 0 U M Li. p W _.i 0 ao = z_ '— a) wm tr1 ~ coC Z O — W Q t< Q I— U cr 0 o -ten L� N L0 0 N O z F— W i O (3) 1/4-DIA. MACHINE TOP VIEW j ' BOLTS w/ WASHERS 4"x4" POST (2) 1/7' DIA. EXPANSION (SEE PAGE-2 COLUMN PER PLAN FOR SIZE) I BOLTS SEE NOTE #2 — (3) 1J4"DIA. MACHINE THIS PAGE FOR BOLT BOLTS w/ WASHERS PLACEMENT 1 /8"x2"x7'x3-3/4" Tx4"x0.125 ANGLE (LENGTH) ANGLE j ( (4j 3/8"x4" TAPCON (INTERNAL) (� li THRU BOTTOM LEG II j U OF ANGLE INTO CONC. (�� �- ap W fn �j o o Cj • e rr W ii U 3000 PSI CONC. � • � � • � • , ' � � � SLAB/FTG. FRONT VIEW 3000 PSI CONC.LLJ6x6-10x10 WWM SLAB/ FIG. FRONT VIEW I W o J Z U OR FIBERMESH 6x6-10x10 WWM O 0 Z OR FIBERMESH U F Q 00 J 4"x4" POST CONNECTION DETAIL 4X4 COLUMN ALT. BASE ATTACHMENT F 0 d SCALE: NTS DETAIL SCALE: NTS z w O of v a DESIGN DATE: 11/11/2020 REVISION 1: REVISION 2: PAGE: DRAWN BY: TCP SCALE: NTS