Loading...
HomeMy WebLinkAboutSTAHLBERG- ENERGY CALC (2)EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 76/22/2020 4:37 PM Project Name: Owner: Builder Name: Permit Office: Jurisdiction: ST LUCIE COUNTY ST LUCIE COUNTY GEORGE AND CHARLOTTE STAHLBERG STAHLBERG RESIDENCE Street: City, State, Zip: FORT PIERCE , FL , 1310 COPENHAVER ROAD Permit Number: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft²) New (From Plans) Single-family 1 No 1868 7. Windows a. U-Factor: S H G C : b. U-Factor: S H G C : c. U-Factor: S H G C : d. U-Factor: S H G C : Sgl, U=1.04 268.50 ft² SHGC=0.25 N/A f t ² N/A f t ² N/A f t ² 8. Floor Types a. Slab-On-Grade Edge Insulation b. N/A c. N/A R=0.0 1868.00 ft² R=f t ² R=f t ² 9. Wall Types a. Concrete Block - Int Insul, Exterior R=4.1 1946.30 ft² b. Frame - Wood, Adjacent R=11.0 373.33 ft² c. N/A R=f t ² 10. Ceiling Types a. Under Attic (Vented)R=30.0 1868.00 ft² f t ² R=b. N/A c. N/A R = f t ² 11. Ducts a. Sup: Attic, Ret: Attic, AH: UTILITY 12. Cooling systems 13. Heating systems 14. Hot water systems a. Electric Cap: 1 gallons b. Conservation features None d. N/A R=f t ² Area Weighted Average Overhang Depth:7.186 ft. Area Weighted Average SHGC:0.250 Description Area Insulation Area Insulation Area Insulation Area 15. Credits None 3 (268.5 sqft.) (2319.7 sqft.) (1868.0 sqft.) (1868.0 sqft.) Conditioned floor area below grade (ft²) 0 a. Central Unit a. Electric Strip Heat k B t u / h r 35.2 SEER:16.00 Efficiency k B t u / h r Efficiency 27.0 COP:1.00 f t ² R 6 150 Tankless EF: 0.990 Glass/Floor Area: 0.144 Total Proposed Modified Loads: Total Baseline Loads: 68.20 68.63 PASS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: BUILDING OFFICIAL: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method FORM R405-2017 6-23-2020 PROJECT Title: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: ST LUCIE COUNTY ST LUCIE COUNTY 1 GEORGE AND CHARLOTTE STAHLBERG RESIDENCE Family Type: New/Existing: Bedrooms: Conditioned Area: Total Stories: Worst Case: Rotate Angle:0 No 1 1868 3 New (From Plans) Single-family Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: FL , FORT PIERCE , St. Lucie 1310 COPENHAVER R Street Address Comment: Building Type: User Cross Ventilation:No Whole House Fan:No TMY Site Design Temp Int Design Temp Heating Design Daily Temp Design Location 2.5 %97.5 %Degree Days Moisture RangeWinter Summer CLIMATE 90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______ Number Name Area Volume BLOCKS 1 Entire House 1868 18208.4 Number Name Area Volume SPACES Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished 1 M BATH 134 1246.2 No 0 Yes Yes1 Yes 2 M TOILET 24 223 No 0 Yes Yes1 Yes 3 M WIC 93 865 No 0 Yes Yes1 Yes 4 HALLWAY 86 795 No 0 Yes Yes1 No 5 CABANA BATH 44 405 No 0 Yes Yes1 Yes 6 UTILITY 57 530 No 0 Yes Yes1 Yes 7 KITCHEN 139 1292.7 Yes 0 Yes Yes1 Yes 8 GREAT ROOM/FO 444 4573 No 0 Yes Yes1 Yes 9 DINING RM 168 1730 No 0 Yes Yes1 Yes 10 BEDROOM 2 191 1776.3 No 0 1 Yes Yes1 Yes 11 CLST 2 18 167 No 0 Yes Yes1 Yes 12 BATH 2 45 419 No 0 Yes Yes1 Yes 13 HALL 27 251 No 0 Yes Yes1 No 14 CLST 3 18 167 No 0 Yes Yes1 Yes 15 BEDROOM 3 156 1450.8 No 0 1 Yes Yes1 Yes 16 MASTER BEDROO 224 2307.2 No 0 1 Yes Yes1 Yes # Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpace Perimeter 1 134 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -020 ft M BATH 2 24 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -06 ft M TOILET 6/22/2020 4:37 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpace Perimeter 3 93 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -05 ft M WIC 4 86 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft HALLWAY 5 44 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -03 ft CABANA BATH 6 57 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -06 ft UTILITY 7 139 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -014.2 ft KITCHEN 8 444 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -031 ft GREAT ROOM/F 9 168 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -014 ft DINING RM 10 191 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -029.2 ft BEDROOM 2 11 18 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -02 ft CLST 2 12 45 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -05 ft BATH 2 13 27 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft HALL 14 18 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -02 ft CLST 3 15 156 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -033 ft BEDROOM 3 16 224 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -030 ft MASTER BEDRO # Type Materials Color Absor. Roof Solar Deck Insul. Pitch ROOF Tested Roof Area Gable Area Emitt Tested EmittSA (deg) Rad Barr 1 Hip Metal 2023 ft² Light 0.1 0 22.6______No0 ft² 0.9 NoN ATTIC # Type Ventilation Area RBS IRCCVent Ratio (1 in) ______ 1 Full attic Vented 1868 ft² N N150 6/22/2020 4:37 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # Ceiling Type R-Value Area Framing Frac Truss Type CEILING Space Ins Type 1 Under Attic (Vented)30 134 ft² 0.1 Wood______M BATH Blown 2 Under Attic (Vented)30 24 ft² 0.1 Wood______M TOILET Blown 3 Under Attic (Vented)30 93 ft² 0.1 Wood______M WIC Blown 4 Under Attic (Vented)30 86 ft² 0.1 Wood______HALLWAY Blown 5 Under Attic (Vented)30 44 ft² 0.1 Wood______CABANA BATH Blown 6 Under Attic (Vented)30 57 ft² 0.1 Wood______UTILITY Blown 7 Under Attic (Vented)30 139 ft² 0.1 Wood______KITCHEN Blown 8 Under Attic (Vented)30 444 ft² 0.1 Wood______GREAT ROOM/F Blown 9 Under Attic (Vented)30 168 ft² 0.1 Wood______DINING RM Blown 10 Under Attic (Vented)30 191 ft² 0.1 Wood______BEDROOM 2 Blown 11 Under Attic (Vented)30 18 ft² 0.1 Wood______CLST 2 Blown 12 Under Attic (Vented)30 45 ft² 0.1 Wood______BATH 2 Blown 13 Under Attic (Vented)30 27 ft² 0.1 Wood______HALL Blown 14 Under Attic (Vented)30 18 ft² 0.1 Wood______CLST 3 Blown 15 Under Attic (Vented)30 156 ft² 0.1 Wood______BEDROOM 3 Blown 16 Under Attic (Vented)30 224 ft² 0.1 Wood______MASTER BEDRO Blown WALLS #Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 1 4.1 0M BATH 04010 9N Concrete Block - Int Insul 0.10Exterior93.3 ft² ____ 2 4.1 0M BATH 04010 9E Concrete Block - Int Insul 0.10Exterior93.3 ft² ____ 3 4.1 0M TOILET 0406 9N Concrete Block - Int Insul 0.10Exterior56.0 ft² ____ 4 4.1 0M WIC 0405 9N Concrete Block - Int Insul 0.10Exterior46.7 ft² ____ 5 11 0M WIC 04017 9W Frame - Wood 0.10.1Garage158.7 ft² ____ 6 11 0HALLWAY0407 9NW Frame - Wood 0.10.1Garage65.3 ft² ____ 7 11 0HALLWAY0408 9N Frame - Wood 0.10.1Garage74.7 ft² ____ 8 4.1 0CABANA BAT 0403 9E Concrete Block - Int Insul 0.10Exterior28.0 ft² ____ 9 4.1 0UTILITY0406 9W Concrete Block - Int Insul 0.10Exterior56.0 ft² ____ 10 11 0UTILITY0408 9N Frame - Wood 0.10.1Garage74.7 ft² ____ 11 4.1 0KITCHEN04010 9E Concrete Block - Int Insul 0.10Exterior93.3 ft² ____ 12 4.1 0KITCHEN0434 9SE Concrete Block - Int Insul 0.10Exterior39.7 ft² ____ 13 4.1 0GREAT ROO 0403 10N Concrete Block - Int Insul 0.10Exterior31.0 ft² ____ 14 4.1 0GREAT ROO 04028 10W Concrete Block - Int Insul 0.10Exterior289.3 ft² ____ 15 4.1 0DINING RM 04014 10E Concrete Block - Int Insul 0.10Exterior144.7 ft² ____ 16 4.1 0BEDROOM 2 0434 9NE Concrete Block - Int Insul 0.10Exterior39.7 ft² ____ 17 4.1 0BEDROOM 2 04010 9E Concrete Block - Int Insul 0.10Exterior93.3 ft² ____ 18 4.1 0BEDROOM 2 04015 9S Concrete Block - Int Insul 0.10Exterior140.0 ft² ____ 19 4.1 0CLST 2 0402 9S Concrete Block - Int Insul 0.10Exterior18.7 ft² ____ 20 4.1 0BATH 2 0405 9S Concrete Block - Int Insul 0.10Exterior46.7 ft² ____ 21 4.1 0CLST 3 0402 9S Concrete Block - Int Insul 0.10Exterior18.7 ft² ____ 22 4.1 0BEDROOM 3 0408 9N Concrete Block - Int Insul 0.10Exterior74.7 ft² ____ 23 4.1 0BEDROOM 3 04013 9S Concrete Block - Int Insul 0.10Exterior121.3 ft² ____ 24 4.1 0BEDROOM 3 04012 9W Concrete Block - Int Insul 0.10Exterior112.0 ft² ____ 6/22/2020 4:37 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS #Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 25 4.1 0MASTER BE 04014 10E Concrete Block - Int Insul 0.10Exterior144.7 ft² ____ 26 4.1 0MASTER BE 04016 10S Concrete Block - Int Insul 0.10Exterior165.3 ft² ____ #Door Type U-Value AreaStorms DOORS Ornt Space Width Ft In Ft In Height 1 Insulated .4 48 ft² None______W GREAT ROO 86 # Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening WINDOWS Overhang Orientation shown is the entered, Proposed orientation. Wall ID Imp 1 E Low-E Single 1.04 0.25 9.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes2 Y 2 E Low-E Single 1.04 0.25 24.0 ft² 1 ft 6 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes8 Y 3 W Low-E Single 1.04 0.25 9.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes9 Y 4 E Low-E Single 1.04 0.25 9.0 ft² 14 ft 0 in 1 ft 4 in NoneMetal None______Yes11 Y 5 SE Low-E Single 1.04 0.25 8.5 ft² 14 ft 0 in 1 ft 4 in NoneMetal None______Yes12 Y 6 W Low-E Single 1.04 0.25 30.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes14 Y 7 E Low-E Single 1.04 0.25 48.0 ft² 16 ft 0 in 1 ft 4 in NoneMetal None______Yes15 Y 8 NE Low-E Single 1.04 0.25 24.0 ft² 14 ft 0 in 1 ft 4 in NoneMetal None______Yes16 Y 9 S Low-E Single 1.04 0.25 15.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes18 Y 10 S Low-E Single 1.04 0.25 9.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes20 Y 11 W Low-E Single 1.04 0.25 15.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes24 Y 12 E Low-E Single 1.04 0.25 20.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes25 Y 13 S Low-E Single 1.04 0.25 48.0 ft² 8 ft 0 in 1 ft 4 in NoneMetal None______Yes26 Y # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation GARAGE 1 504 ft² 504 ft² 50 ft 9 ft 11______ Method CFM 50 ACH 50ELASLAScope INFILTRATION ACHEqLA# 2123.1 7116.56.000433Wholehouse .1625219.2Proposed ACH(50)1 HEATING SYSTEM # System Type Efficiency Capacity DuctsSubtypeBlockSpeed 1 Electric Strip Heat/COP:1 27 kBtu/hr ______sys#1None1 6/22/2020 4:37 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # System Type Efficiency Capacity Air Flow SHR COOLING SYSTEM DuctsSubtypeBlockSubtype 1 Central Unit/SEER: 16 35.2 kBtu/hr 1056 cfm 0.8______sys#1Split1 Single # System Type EF Cap Use SetPnt Conservation HOT WATER SYSTEM SubType Location 1 Electric 0.99 1 gal 55.1 gal 120 deg None______Tankless Exterior FSEC Company Name System Model #Collector Model # Collector SOLAR HOT WATER SYSTEM Storage FEFCert #Area Volume None None f t ² ______ # Location R-Value Area Location Area ---- Supply -------- Return ---- Leakage Type Handler CFM 25Air QN RLF DUCTS Heat Cool HVAC # TOT OUT CFM25 1 Attic 6 150 ft² Attic 15 ft² Default Leakage UTILITY (Default) c______1 1 (Default) c TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec [ ] Dec [X] Dec[X] Nov [X] Nov [ ] Oct [X] Oct [ ] Sep [ ] Sep [ ] Aug [ ] Aug [ ] Jul [ ] Jul[ ] Jun [ ] Jun [X] Jun [ ] May [ ] May [ ] Apr [X] Apr [X] Mar [X] Mar [X] Feb [ ] Feb [X] Jan [ ] Jan Heating Venting Thermostat Schedule:HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD)AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Cooling (WEH)AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Heating (WD)AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH)AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 M BATH Default(8 lbs/sq.ft.f t ² f t 0.3 M TOILET Default(8 lbs/sq.ft.f t ² f t 0.3 M WIC Default(8 lbs/sq.ft.f t ² f t 0.3 HALLWAY Default(8 lbs/sq.ft.f t ² f t 0.3 CABANA BATH Default(8 lbs/sq.ft.f t ² f t 0.3 UTILITY Default(8 lbs/sq.ft.f t ² f t 0.3 KITCHEN Default(8 lbs/sq.ft.f t ² f t 0.3 GREAT ROOM/FO Default(8 lbs/sq.ft.f t ² f t 0.3 DINING RM Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 2 Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 2 Default(8 lbs/sq.ft.f t ² f t 0.3 BATH 2 6/22/2020 4:37 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft.f t ² f t 0.3 HALL Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 3 Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 3 Default(8 lbs/sq.ft.f t ² f t 0.3 MASTER BEDROO 6/22/2020 4:37 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT ��������������������������������������������������������������������������� ��������������������������������������������������������������������������������� �����������������������������������������������������