HomeMy WebLinkAboutSTAHLBERG- ENERGY CALC (2)EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 76/22/2020 4:37 PM
Project Name:
Owner:
Builder Name:
Permit Office:
Jurisdiction: ST LUCIE COUNTY
ST LUCIE COUNTY
GEORGE AND CHARLOTTE STAHLBERG
STAHLBERG RESIDENCE
Street:
City, State, Zip: FORT PIERCE , FL ,
1310 COPENHAVER ROAD
Permit Number:
Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area above grade (ft²)
New (From Plans)
Single-family
1
No
1868
7. Windows
a. U-Factor:
S H G C :
b. U-Factor:
S H G C :
c. U-Factor:
S H G C :
d. U-Factor:
S H G C :
Sgl, U=1.04 268.50 ft²
SHGC=0.25
N/A f t ²
N/A f t ²
N/A f t ²
8. Floor Types
a. Slab-On-Grade Edge Insulation
b. N/A
c. N/A
R=0.0 1868.00 ft²
R=f t ²
R=f t ²
9. Wall Types
a. Concrete Block - Int Insul, Exterior R=4.1 1946.30 ft²
b. Frame - Wood, Adjacent R=11.0 373.33 ft²
c. N/A R=f t ²
10. Ceiling Types
a. Under Attic (Vented)R=30.0 1868.00 ft²
f t ² R=b. N/A
c. N/A R = f t ²
11. Ducts
a. Sup: Attic, Ret: Attic, AH: UTILITY
12. Cooling systems
13. Heating systems
14. Hot water systems
a. Electric Cap: 1 gallons
b. Conservation features
None
d. N/A R=f t ²
Area Weighted Average Overhang Depth:7.186 ft.
Area Weighted Average SHGC:0.250
Description Area
Insulation Area
Insulation Area
Insulation Area
15. Credits None
3
(268.5 sqft.)
(2319.7 sqft.)
(1868.0 sqft.)
(1868.0 sqft.)
Conditioned floor area below grade (ft²) 0
a. Central Unit
a. Electric Strip Heat
k B t u / h r
35.2 SEER:16.00
Efficiency
k B t u / h r Efficiency
27.0 COP:1.00
f t ² R
6 150
Tankless
EF: 0.990
Glass/Floor Area: 0.144
Total Proposed Modified Loads:
Total Baseline Loads:
68.20
68.63 PASS
I hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Code.
PREPARED BY:
DATE:
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGENT:
DATE:
BUILDING OFFICIAL:
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
FORM R405-2017
6-23-2020
PROJECT
Title:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction: ST LUCIE COUNTY
ST LUCIE COUNTY
1
GEORGE AND CHARLOTTE
STAHLBERG RESIDENCE
Family Type:
New/Existing:
Bedrooms:
Conditioned Area:
Total Stories:
Worst Case:
Rotate Angle:0
No
1
1868
3
New (From Plans)
Single-family
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
FL ,
FORT PIERCE ,
St. Lucie
1310 COPENHAVER R
Street Address
Comment:
Building Type: User
Cross Ventilation:No
Whole House Fan:No
TMY Site
Design Temp Int Design Temp Heating Design Daily Temp
Design Location 2.5 %97.5 %Degree Days Moisture RangeWinter Summer
CLIMATE
90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______
Number Name Area Volume
BLOCKS
1 Entire House 1868 18208.4
Number Name Area Volume
SPACES
Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished
1 M BATH 134 1246.2 No 0 Yes Yes1 Yes
2 M TOILET 24 223 No 0 Yes Yes1 Yes
3 M WIC 93 865 No 0 Yes Yes1 Yes
4 HALLWAY 86 795 No 0 Yes Yes1 No
5 CABANA BATH 44 405 No 0 Yes Yes1 Yes
6 UTILITY 57 530 No 0 Yes Yes1 Yes
7 KITCHEN 139 1292.7 Yes 0 Yes Yes1 Yes
8 GREAT ROOM/FO 444 4573 No 0 Yes Yes1 Yes
9 DINING RM 168 1730 No 0 Yes Yes1 Yes
10 BEDROOM 2 191 1776.3 No 0 1 Yes Yes1 Yes
11 CLST 2 18 167 No 0 Yes Yes1 Yes
12 BATH 2 45 419 No 0 Yes Yes1 Yes
13 HALL 27 251 No 0 Yes Yes1 No
14 CLST 3 18 167 No 0 Yes Yes1 Yes
15 BEDROOM 3 156 1450.8 No 0 1 Yes Yes1 Yes
16 MASTER BEDROO 224 2307.2 No 0 1 Yes Yes1 Yes
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
1 134 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -020 ft M BATH
2 24 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -06 ft M TOILET
6/22/2020 4:37 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
3 93 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -05 ft M WIC
4 86 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft HALLWAY
5 44 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -03 ft CABANA BATH
6 57 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -06 ft UTILITY
7 139 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -014.2 ft KITCHEN
8 444 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -031 ft GREAT ROOM/F
9 168 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -014 ft DINING RM
10 191 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -029.2 ft BEDROOM 2
11 18 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -02 ft CLST 2
12 45 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -05 ft BATH 2
13 27 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft HALL
14 18 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -02 ft CLST 3
15 156 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -033 ft BEDROOM 3
16 224 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -030 ft MASTER BEDRO
# Type Materials Color Absor.
Roof Solar Deck
Insul.
Pitch
ROOF
Tested
Roof
Area
Gable
Area
Emitt
Tested
EmittSA
(deg)
Rad
Barr
1 Hip Metal 2023 ft² Light 0.1 0 22.6______No0 ft² 0.9 NoN
ATTIC
# Type Ventilation Area RBS IRCCVent Ratio (1 in)
______ 1 Full attic Vented 1868 ft² N N150
6/22/2020 4:37 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
# Ceiling Type R-Value Area Framing Frac Truss Type
CEILING
Space Ins Type
1 Under Attic (Vented)30 134 ft² 0.1 Wood______M BATH Blown
2 Under Attic (Vented)30 24 ft² 0.1 Wood______M TOILET Blown
3 Under Attic (Vented)30 93 ft² 0.1 Wood______M WIC Blown
4 Under Attic (Vented)30 86 ft² 0.1 Wood______HALLWAY Blown
5 Under Attic (Vented)30 44 ft² 0.1 Wood______CABANA BATH Blown
6 Under Attic (Vented)30 57 ft² 0.1 Wood______UTILITY Blown
7 Under Attic (Vented)30 139 ft² 0.1 Wood______KITCHEN Blown
8 Under Attic (Vented)30 444 ft² 0.1 Wood______GREAT ROOM/F Blown
9 Under Attic (Vented)30 168 ft² 0.1 Wood______DINING RM Blown
10 Under Attic (Vented)30 191 ft² 0.1 Wood______BEDROOM 2 Blown
11 Under Attic (Vented)30 18 ft² 0.1 Wood______CLST 2 Blown
12 Under Attic (Vented)30 45 ft² 0.1 Wood______BATH 2 Blown
13 Under Attic (Vented)30 27 ft² 0.1 Wood______HALL Blown
14 Under Attic (Vented)30 18 ft² 0.1 Wood______CLST 3 Blown
15 Under Attic (Vented)30 156 ft² 0.1 Wood______BEDROOM 3 Blown
16 Under Attic (Vented)30 224 ft² 0.1 Wood______MASTER BEDRO Blown
WALLS
#Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
1 4.1 0M BATH 04010 9N Concrete Block - Int Insul 0.10Exterior93.3 ft² ____
2 4.1 0M BATH 04010 9E Concrete Block - Int Insul 0.10Exterior93.3 ft² ____
3 4.1 0M TOILET 0406 9N Concrete Block - Int Insul 0.10Exterior56.0 ft² ____
4 4.1 0M WIC 0405 9N Concrete Block - Int Insul 0.10Exterior46.7 ft² ____
5 11 0M WIC 04017 9W Frame - Wood 0.10.1Garage158.7 ft² ____
6 11 0HALLWAY0407 9NW Frame - Wood 0.10.1Garage65.3 ft² ____
7 11 0HALLWAY0408 9N Frame - Wood 0.10.1Garage74.7 ft² ____
8 4.1 0CABANA BAT 0403 9E Concrete Block - Int Insul 0.10Exterior28.0 ft² ____
9 4.1 0UTILITY0406 9W Concrete Block - Int Insul 0.10Exterior56.0 ft² ____
10 11 0UTILITY0408 9N Frame - Wood 0.10.1Garage74.7 ft² ____
11 4.1 0KITCHEN04010 9E Concrete Block - Int Insul 0.10Exterior93.3 ft² ____
12 4.1 0KITCHEN0434 9SE Concrete Block - Int Insul 0.10Exterior39.7 ft² ____
13 4.1 0GREAT ROO 0403 10N Concrete Block - Int Insul 0.10Exterior31.0 ft² ____
14 4.1 0GREAT ROO 04028 10W Concrete Block - Int Insul 0.10Exterior289.3 ft² ____
15 4.1 0DINING RM 04014 10E Concrete Block - Int Insul 0.10Exterior144.7 ft² ____
16 4.1 0BEDROOM 2 0434 9NE Concrete Block - Int Insul 0.10Exterior39.7 ft² ____
17 4.1 0BEDROOM 2 04010 9E Concrete Block - Int Insul 0.10Exterior93.3 ft² ____
18 4.1 0BEDROOM 2 04015 9S Concrete Block - Int Insul 0.10Exterior140.0 ft² ____
19 4.1 0CLST 2 0402 9S Concrete Block - Int Insul 0.10Exterior18.7 ft² ____
20 4.1 0BATH 2 0405 9S Concrete Block - Int Insul 0.10Exterior46.7 ft² ____
21 4.1 0CLST 3 0402 9S Concrete Block - Int Insul 0.10Exterior18.7 ft² ____
22 4.1 0BEDROOM 3 0408 9N Concrete Block - Int Insul 0.10Exterior74.7 ft² ____
23 4.1 0BEDROOM 3 04013 9S Concrete Block - Int Insul 0.10Exterior121.3 ft² ____
24 4.1 0BEDROOM 3 04012 9W Concrete Block - Int Insul 0.10Exterior112.0 ft² ____
6/22/2020 4:37 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
#Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
25 4.1 0MASTER BE 04014 10E Concrete Block - Int Insul 0.10Exterior144.7 ft² ____
26 4.1 0MASTER BE 04016 10S Concrete Block - Int Insul 0.10Exterior165.3 ft² ____
#Door Type U-Value AreaStorms
DOORS
Ornt Space Width
Ft In Ft In
Height
1 Insulated .4 48 ft² None______W GREAT ROO 86
# Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening
WINDOWS
Overhang
Orientation shown is the entered, Proposed orientation.
Wall
ID Imp
1 E Low-E Single 1.04 0.25 9.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes2 Y
2 E Low-E Single 1.04 0.25 24.0 ft² 1 ft 6 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes8 Y
3 W Low-E Single 1.04 0.25 9.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes9 Y
4 E Low-E Single 1.04 0.25 9.0 ft² 14 ft 0 in 1 ft 4 in NoneMetal None______Yes11 Y
5 SE Low-E Single 1.04 0.25 8.5 ft² 14 ft 0 in 1 ft 4 in NoneMetal None______Yes12 Y
6 W Low-E Single 1.04 0.25 30.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes14 Y
7 E Low-E Single 1.04 0.25 48.0 ft² 16 ft 0 in 1 ft 4 in NoneMetal None______Yes15 Y
8 NE Low-E Single 1.04 0.25 24.0 ft² 14 ft 0 in 1 ft 4 in NoneMetal None______Yes16 Y
9 S Low-E Single 1.04 0.25 15.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes18 Y
10 S Low-E Single 1.04 0.25 9.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes20 Y
11 W Low-E Single 1.04 0.25 15.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes24 Y
12 E Low-E Single 1.04 0.25 20.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes25 Y
13 S Low-E Single 1.04 0.25 48.0 ft² 8 ft 0 in 1 ft 4 in NoneMetal None______Yes26 Y
# Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
GARAGE
1 504 ft² 504 ft² 50 ft 9 ft 11______
Method CFM 50 ACH 50ELASLAScope
INFILTRATION
ACHEqLA#
2123.1 7116.56.000433Wholehouse .1625219.2Proposed ACH(50)1
HEATING SYSTEM
# System Type Efficiency Capacity DuctsSubtypeBlockSpeed
1 Electric Strip Heat/COP:1 27 kBtu/hr ______sys#1None1
6/22/2020 4:37 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
# System Type Efficiency Capacity Air Flow SHR
COOLING SYSTEM
DuctsSubtypeBlockSubtype
1 Central Unit/SEER: 16 35.2 kBtu/hr 1056 cfm 0.8______sys#1Split1 Single
# System Type EF Cap Use SetPnt Conservation
HOT WATER SYSTEM
SubType Location
1 Electric 0.99 1 gal 55.1 gal 120 deg None______Tankless Exterior
FSEC
Company Name System Model #Collector Model #
Collector
SOLAR HOT WATER SYSTEM
Storage
FEFCert #Area Volume
None None f t ² ______
# Location R-Value Area Location Area
---- Supply -------- Return ----
Leakage Type Handler
CFM 25Air
QN RLF
DUCTS
Heat Cool
HVAC #
TOT OUT
CFM25
1 Attic 6 150 ft² Attic 15 ft² Default Leakage UTILITY (Default) c______1 1 (Default) c
TEMPERATURES
Programable Thermostat: N Ceiling Fans:
Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec
[ ] Dec
[X] Dec[X] Nov
[X] Nov
[ ] Oct
[X] Oct
[ ] Sep
[ ] Sep
[ ] Aug
[ ] Aug
[ ] Jul
[ ] Jul[ ] Jun
[ ] Jun
[X] Jun
[ ] May
[ ] May
[ ] Apr
[X] Apr
[X] Mar
[X] Mar
[X] Feb
[ ] Feb
[X] Jan
[ ] Jan
Heating
Venting
Thermostat Schedule:HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling (WD)AM
PM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Cooling (WEH)AM
PM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Heating (WD)AM
PM
65
68
65
68
65
68
65
68
65
68
65
68
65
68
68
68
68
68
68
68
68
68
68
68
Heating (WEH)AM
PM
65
68
65
68
65
68
65
68
65
68
65
68
65
68
68
68
68
68
68
68
68
68
68
68
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 M BATH
Default(8 lbs/sq.ft.f t ² f t 0.3 M TOILET
Default(8 lbs/sq.ft.f t ² f t 0.3 M WIC
Default(8 lbs/sq.ft.f t ² f t 0.3 HALLWAY
Default(8 lbs/sq.ft.f t ² f t 0.3 CABANA BATH
Default(8 lbs/sq.ft.f t ² f t 0.3 UTILITY
Default(8 lbs/sq.ft.f t ² f t 0.3 KITCHEN
Default(8 lbs/sq.ft.f t ² f t 0.3 GREAT ROOM/FO
Default(8 lbs/sq.ft.f t ² f t 0.3 DINING RM
Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 2
Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 2
Default(8 lbs/sq.ft.f t ² f t 0.3 BATH 2
6/22/2020 4:37 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 lbs/sq.ft.f t ² f t 0.3 HALL
Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 3
Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 3
Default(8 lbs/sq.ft.f t ² f t 0.3 MASTER BEDROO
6/22/2020 4:37 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
���������������������������������������������������������������������������
���������������������������������������������������������������������������������
�����������������������������������������������������