Loading...
HomeMy WebLinkAboutBoral Saxony 900 Concrete Roof TileM IAMI·DADE DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Moral Roofing, LLC 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.wov/economv SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (in Miami-Dade County) and/or the AHJ (in areas other than Miami-Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Saxony 900 Concrete Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the j ob site at the request of the Building Official. This NOA renews NOA No.13-0723.05 and consists of pages 1 through 8. The submitted documentation was reviewed by Gaspar J Rodriguez. APPROVED L 4\4-NOA No.: 16-0711.05 Expiration Date: 04/26/22 Approval Date: 09/29/16 Page 1 of 8 ROOFING AsSEMBLY APPROVAL Cateaorv: Sub-Category: Material: Deck Tvve: 1. SCOPE Roofing Roofing Tiles Concrete Wood This NOA approves a system using Saxony 900 (Slate, Shake & Split Shake) Concrete Roof Tile, as manufactured Boral Roofing LLC in Lake Wales, FL and described this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in the installation section herein. The attachment calculations shall be done as a moment based system. PRODUCT DESCRIPTION2. Manufactured bv Applicant Saxony 900-Slate Saxony 900 Split Shake Saxony 900-Shake Trim Pieces APPROVED L Dimensions Length = 17" Width = 13" thickness = 1-5/32" Length = 17" Width = 13" thickness = 1-9/32" Length = 17" Width = 13" thickness = 1-9/32" Length: varies Width: varies varying thickness Test Specifications TAS 112 TAS 112 TAS 112 TAS-112 Product Description Flat profile, interlocking, high-pressure extruded concrete roof tile with two nail holes. For direct deck, batten, mortar set or adhesive set applications. Flat profile, interlocking, high-pressure extruded concrete roof tile with two nail holes. For direct deck, batten, mortar set or adhesive set applications. Top surface produced with 4 different configurations: 1. Complete tile brushed 2. Right half brushed (shown in drawing) 3. Left half brushed 4. No brush Flat profile, interlocking, high-pressure extruded concrete roof tile with two nail holes. For direct deck, batten, mortar set or adhesive set applications. Accessory trim, boosted Barcelona, concrete roof pieces for use at hips, ridges and rakes. NOA No.: 16-0711.05 Expiration Date: 04/26/22 Approval Date: 09/29/16 Page 2 of 8 2.1 MANUFACTURING LOCATION 2.1.1 Lake Wales, FL 2.2 EVIDENCE SUBMITTED: Test Aeencv Test Identifier The Center for Applied 94-084 Engineering, Inc. The Center for Applied 94-060A Engineering, Inc. The Center for Applied 25-7183-6 Engineering, Inc. The Center for Applied 25-7183-5 Engineering, Inc. The Center for Applied 25-7214-1 Engineering, Inc. The Center for Applied 25-7214-5 Engineering, Inc. The Center for Applied Project No. 307025 Engineering, Inc.Test #MDC-77 Redland Technologies Redland Technologies Redland Technologies Redland Technologies Atlanta Testing & Engineering, Inc. Celotex Corporation Testing Service Celotex Corporation Testing Service Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. American Test Lab of South Florida APPROVED L 7161-03 Appendix II & III Letter Dated Aug. 1, 1994 P0631-01 P0402 Rl.894/le.894/R3.894 520109-1 520111-4 520191-1 Evaluation Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations Calculations Evaluation Calculations RT0617.04-16 Test Name/Report Static Uplift Testing TAS 101 (Mortar Set) Static Uplift Testing TAS 101 (Adhesive Set) Static Uplift Testing TAS 102 (2 Quik-Drive Screws, Direct Deck) Static Uplift Testing TAS 102 (2 Quik-Drive Screws, Battens) Static Uplift Testing TAS 102 (1 Quik-Drive Screw, Direct Deck) Static Uplift Testing TAS 102 (1 Quik-Drive Screw, Battens) Wind Driven Rain TAS 100 Wind Tunnel Testing TAS 108 (Nail-On) Wind Tunnel Testing TAS 108 (Nail-On) Wind Tunnel Testing TAS 108 (Mortar Set) Withdrawal Resistance Testing of screw vs. smooth shank nails Physical Properties TAS 112 Static Uplift Testing TAS 101 Static Uplift Testing TAS 101 25-7094 25-7496 25-7584/25-7804b-8/25-7804-4 & 5 25-7848-6 25-7183 Aerodynamic Multipliers Two Patty Adhesive Set System Restoring Moments Due to Gravity TAS 112 Date May 1994 March, 1994 Feb. 1995 Feb. 1995 March, 1995 March, 1995 Oct. 1994 Dec. 1991 Aug. 1994 July 1994 Sept. 1993 Aug. 1994 Dec. 1998 March 1999 February 1996 April 1996 December 1996 March 1995 09/01/16 April 1999 09/01/16 06/29/16 NOA No.: 16-0711.05 Expiration Date: 04/26/22 Approval Date: 09/29/16 Page 3 of 8 3. LIMITATIONS 3.1 3.2 3.3 3.4 3.5 3.6 Fire classification is not part of this acceptance. For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix 'A'. Such testing shall be submitted to the Building Code Compliance Office for review. Minimum underlayments shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with the applicable Building Code. 4. INSTALLATION 4.1 Saxony 900 (Slate, Shake & Split Shake) Concrete Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Tile Profile Saxony 900 Slate, Shake & Split Shake Tile Prole Saxony 900 Slate, Shake & Split Shake Tile Profile Saxony 900 Slate, Shake & Split Shake APPROVED L Table 1: Average Weight (W) and Dimensions (1 xw) Weight-W (Ibf) 10.9 Length-1 (ft) 1.417 Table 2: Aerodynamic Multipliers - 1 (ft3) 1 (ft3) Batten Application 0.291 Table 3: Restoring Moments due to Gravity - Mg (ft-'bf) 2":12" Direct Deck 7.70 3":12" Direct Deck 7.62 4": 12" Battens 6.61 Direct Deck 7.50 5":12" Battens 6.48 Direct Deck 7.34 Width-w (ft) 1.08 X (ft3) Direct Deck Application 6": 12" Battens 6.31 Direct Deck 7.16 0.315 7":12" or greater Battens 6.13 Direct Deck 6.95 NOA No.: 16-0711.05 Expiration Date: 04/26/22 Approval Date: 09/29/16 Page 4 of 8 Tile Profile Saxony 900 Slate, Shake & Split Shake Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Mechanically Fastened Systems Fastener Type 2-1 Od Ring Shank Nails 1 -1 Od Smooth or Screw Shank Nail 2-1 Od Smooth or Screw Shank Nails 1 .#8 Screw 2.#8 Screws 1 -1 Od Smooth or Screw Shank Nail (Field Clip) 1 -1 Od Smooth or Screw Shank Nail (Eave Clip) 2-1 Od Smooth or Screw Shank Nails (Field Clip) 2-1 Od Smooth or Screw Shank Nails (Eave Clip) 30.9 7.3 14.0 30.8 51.7 24.3 Direct Deck (min 15/32" plywood) 19.0 35.5 31.9 Direct Deck (min. 19/32" plywood) 38.1 9.8 18.8 30.8 51.7 24.3 19.0 35.5 31.9 Table 5: Attachment Resistance Expressed as a Moment IVIf (ft-Ibf) for Two Paddy Adhesive Set Systems Tile Profile Saxony 900 Slate, Shake & Split Shake Tile Application Adhesivel 1 See foam adhesive manufacturer's component approval for installation requirements. 2 The Dow Chemical Company TileBond™ one-component foam minimum weight per paddy 13.9 grams. 3 ICP Adhesives Polyset® RTA-1, one-component foam, minimum weight per paddy 8 grams. Battens 17.2 4.9 7.4 18.2 24.4 24.2 22.1 34.8 32.2 Minimum Attachment Resistance Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Single Paddy Adhesive Set Systems Tile Profile Saxony 900 Slate, Shake & Split Shake Tile Application ICP Adhesives Polyset® AH-160 Two-component foam 4 Large paddy placement of 45 grams of Polyset® AH-160. 5 Medium paddy placement of 24 grams of Polyset® AH-160. 3132 & 3 Minimum Attachment Resistance Table 7: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Mortar Set Systems Tile Profile Saxony 900 Slate, Shake & Split Shake 6 Tile-Tite Roof Tile Mortar APPROVED L Tile Application Mortar Set6 118.94 40.45 Minimum Attachment Resistance 43.96 NOA No.: 16-0711.05 Expiration Date: 04/26/22 Approval Date: 09/29/16 Page 5 of 8 6 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as detailed below, or following statement: "Miami-Dade County Product Control Approved". LABEL FOR BORAL SAXONY 900 TILES (LAKE WALES FL PLANT) LOCATED UNDERNEATH TILE BUILDING PERMIT REQUIREMENTS 6.1 NAIL HOLES Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. APPROVED L 17 " PROFILE DRAWINGS UNDERLOCK SAXON¥ 900 -SLATE 13" 1-5/32" (Slate) COVERLOCK NOA No.: 16-0711.05 Expiration Date: 04/26/22 Approval Date: 09/29/16 Page 6 of 8 1 NAIL HOLES PROFILE DRAWINGS 17"13" Note: Available Top Surface Finishes 5. Complete tile brushed 6. Right half brushed (shown in drawing) 7. Left half brushed 8. No brush APPROVED L SAXON¥ 900 - SPLIT SHAKE 1-9/32" (Shake) NOA No.: 16-0711.05 Expiration Date: 04/26/22 Approval Date: 09/29/16 Page 7 of 8 NAIL HOLES APPROVED L PROFILE DRAWINGS 17" SAXONY 900- SHAKE END OF THIS ACCEPTANCE 13" 1-9/32" (Shake) NOA No.: 16-0711.05 Expiration Date: 04/26/22 Approval Date: 09/29/16 Page 8 of 8