HomeMy WebLinkAboutBoral Saxony 900 Concrete Roof TileM IAMI·DADE
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA)
Moral Roofing, LLC
7575 Irvine Center Drive, Suite 100
Irvine, CA 92618
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
www.miamidade.wov/economv
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be
used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(in Miami-Dade County) and/or the AHJ (in areas other than Miami-Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Saxony 900 Concrete Roof Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration
date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the j ob site at the request of the Building Official.
This NOA renews NOA No.13-0723.05 and consists of pages 1 through 8.
The submitted documentation was reviewed by Gaspar J Rodriguez.
APPROVED L
4\4-NOA No.: 16-0711.05
Expiration Date: 04/26/22
Approval Date: 09/29/16
Page 1 of 8
ROOFING AsSEMBLY APPROVAL
Cateaorv:
Sub-Category:
Material:
Deck Tvve:
1. SCOPE
Roofing
Roofing Tiles
Concrete
Wood
This NOA approves a system using Saxony 900 (Slate, Shake & Split Shake) Concrete Roof Tile, as
manufactured Boral Roofing LLC in Lake Wales, FL and described this Notice of Acceptance. For locations
where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure
values obtained by calculations in compliance with RAS 127 using the values listed in the installation section
herein. The attachment calculations shall be done as a moment based system.
PRODUCT DESCRIPTION2.
Manufactured bv
Applicant
Saxony 900-Slate
Saxony 900
Split Shake
Saxony 900-Shake
Trim Pieces
APPROVED L
Dimensions
Length = 17"
Width = 13"
thickness = 1-5/32"
Length = 17"
Width = 13"
thickness = 1-9/32"
Length = 17"
Width = 13"
thickness = 1-9/32"
Length: varies
Width: varies
varying thickness
Test
Specifications
TAS 112
TAS 112
TAS 112
TAS-112
Product
Description
Flat profile, interlocking, high-pressure extruded
concrete roof tile with two nail holes. For direct deck,
batten, mortar set or adhesive set applications.
Flat profile, interlocking, high-pressure extruded
concrete roof tile with two nail holes. For direct deck,
batten, mortar set or adhesive set applications. Top
surface produced with 4 different configurations:
1. Complete tile brushed
2. Right half brushed (shown in drawing)
3. Left half brushed
4. No brush
Flat profile, interlocking, high-pressure extruded
concrete roof tile with two nail holes. For direct deck,
batten, mortar set or adhesive set applications.
Accessory trim, boosted Barcelona, concrete roof
pieces for use at hips, ridges and rakes.
NOA No.: 16-0711.05
Expiration Date: 04/26/22
Approval Date: 09/29/16
Page 2 of 8
2.1 MANUFACTURING LOCATION
2.1.1 Lake Wales, FL
2.2 EVIDENCE SUBMITTED:
Test Aeencv Test Identifier
The Center for Applied 94-084
Engineering, Inc.
The Center for Applied 94-060A
Engineering, Inc.
The Center for Applied 25-7183-6
Engineering, Inc.
The Center for Applied 25-7183-5
Engineering, Inc.
The Center for Applied 25-7214-1
Engineering, Inc.
The Center for Applied 25-7214-5
Engineering, Inc.
The Center for Applied Project No. 307025
Engineering, Inc.Test #MDC-77
Redland Technologies
Redland Technologies
Redland Technologies
Redland Technologies
Atlanta Testing &
Engineering, Inc.
Celotex Corporation
Testing Service
Celotex Corporation
Testing Service
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
American Test Lab of
South Florida
APPROVED L
7161-03
Appendix II & III
Letter Dated Aug. 1, 1994
P0631-01
P0402
Rl.894/le.894/R3.894
520109-1
520111-4
520191-1
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
Calculations
Evaluation Calculations
RT0617.04-16
Test Name/Report
Static Uplift Testing
TAS 101 (Mortar Set)
Static Uplift Testing
TAS 101 (Adhesive Set)
Static Uplift Testing TAS 102
(2 Quik-Drive Screws, Direct Deck)
Static Uplift Testing TAS 102
(2 Quik-Drive Screws, Battens)
Static Uplift Testing TAS 102
(1 Quik-Drive Screw, Direct Deck)
Static Uplift Testing TAS 102
(1 Quik-Drive Screw, Battens)
Wind Driven Rain
TAS 100
Wind Tunnel Testing
TAS 108 (Nail-On)
Wind Tunnel Testing
TAS 108 (Nail-On)
Wind Tunnel Testing
TAS 108 (Mortar Set)
Withdrawal Resistance Testing of
screw vs. smooth shank nails
Physical Properties
TAS 112
Static Uplift Testing
TAS 101
Static Uplift Testing
TAS 101
25-7094
25-7496
25-7584/25-7804b-8/25-7804-4 & 5
25-7848-6
25-7183
Aerodynamic Multipliers
Two Patty Adhesive Set System
Restoring Moments Due to Gravity
TAS 112
Date
May 1994
March, 1994
Feb. 1995
Feb. 1995
March, 1995
March, 1995
Oct. 1994
Dec. 1991
Aug. 1994
July 1994
Sept. 1993
Aug. 1994
Dec. 1998
March 1999
February 1996
April 1996
December 1996
March 1995
09/01/16
April 1999
09/01/16
06/29/16
NOA No.: 16-0711.05
Expiration Date: 04/26/22
Approval Date: 09/29/16
Page 3 of 8
3. LIMITATIONS
3.1
3.2
3.3
3.4
3.5
3.6
Fire classification is not part of this acceptance.
For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with
TAS 106.
Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test
in accordance with TAS 112, appendix 'A'. Such testing shall be submitted to the Building Code
Compliance Office for review.
Minimum underlayments shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
the applicable Building Code.
4. INSTALLATION
4.1 Saxony 900 (Slate, Shake & Split Shake) Concrete Roof Tile and its components shall be installed in strict
compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120.
4.2 Data For Attachment Calculations
Tile Profile
Saxony 900
Slate, Shake & Split Shake
Tile
Prole
Saxony 900
Slate, Shake & Split Shake
Tile
Profile
Saxony 900
Slate, Shake &
Split Shake
APPROVED L
Table 1: Average Weight (W) and Dimensions (1 xw)
Weight-W (Ibf)
10.9
Length-1 (ft)
1.417
Table 2: Aerodynamic Multipliers - 1 (ft3)
1 (ft3)
Batten Application
0.291
Table 3: Restoring Moments due to Gravity - Mg (ft-'bf)
2":12"
Direct Deck
7.70
3":12"
Direct Deck
7.62
4": 12"
Battens
6.61
Direct
Deck
7.50
5":12"
Battens
6.48
Direct
Deck
7.34
Width-w (ft)
1.08
X (ft3)
Direct Deck Application
6": 12"
Battens
6.31
Direct
Deck
7.16
0.315
7":12" or
greater
Battens
6.13
Direct
Deck
6.95
NOA No.: 16-0711.05
Expiration Date: 04/26/22
Approval Date: 09/29/16
Page 4 of 8
Tile
Profile
Saxony 900
Slate, Shake & Split
Shake
Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf)
for Mechanically Fastened Systems
Fastener Type
2-1 Od Ring Shank Nails
1 -1 Od Smooth or Screw Shank Nail
2-1 Od Smooth or Screw Shank Nails
1 .#8 Screw
2.#8 Screws
1 -1 Od Smooth or Screw Shank Nail (Field
Clip)
1 -1 Od Smooth or Screw Shank Nail (Eave
Clip)
2-1 Od Smooth or Screw Shank Nails (Field
Clip)
2-1 Od Smooth or Screw Shank Nails (Eave
Clip)
30.9
7.3
14.0
30.8
51.7
24.3
Direct Deck
(min 15/32"
plywood)
19.0
35.5
31.9
Direct Deck
(min. 19/32"
plywood)
38.1
9.8
18.8
30.8
51.7
24.3
19.0
35.5
31.9
Table 5: Attachment Resistance Expressed as a Moment IVIf (ft-Ibf)
for Two Paddy Adhesive Set Systems
Tile
Profile
Saxony 900 Slate, Shake & Split Shake
Tile Application
Adhesivel
1 See foam adhesive manufacturer's component approval for installation requirements.
2 The Dow Chemical Company TileBond™ one-component foam minimum weight per paddy 13.9 grams.
3 ICP Adhesives Polyset® RTA-1, one-component foam, minimum weight per paddy 8 grams.
Battens
17.2
4.9
7.4
18.2
24.4
24.2
22.1
34.8
32.2
Minimum Attachment
Resistance
Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf)
for Single Paddy Adhesive Set Systems
Tile
Profile
Saxony 900 Slate, Shake & Split Shake
Tile Application
ICP Adhesives Polyset® AH-160
Two-component foam
4 Large paddy placement of 45 grams of Polyset® AH-160.
5 Medium paddy placement of 24 grams of Polyset® AH-160.
3132 & 3
Minimum Attachment
Resistance
Table 7: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf)
for Mortar Set Systems
Tile
Profile
Saxony 900 Slate, Shake & Split Shake
6 Tile-Tite Roof Tile Mortar
APPROVED L
Tile
Application
Mortar Set6
118.94
40.45
Minimum Attachment
Resistance
43.96
NOA No.: 16-0711.05
Expiration Date: 04/26/22
Approval Date: 09/29/16
Page 5 of 8
6
5. LABELING
5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as detailed
below, or following statement: "Miami-Dade County Product Control Approved".
LABEL FOR BORAL SAXONY 900 TILES (LAKE WALES FL PLANT)
LOCATED UNDERNEATH TILE
BUILDING PERMIT REQUIREMENTS
6.1
NAIL HOLES
Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by the Building Official or applicable building code in order to
properly evaluate the installation of this system.
APPROVED L
17 "
PROFILE DRAWINGS
UNDERLOCK
SAXON¥ 900 -SLATE
13"
1-5/32" (Slate)
COVERLOCK
NOA No.: 16-0711.05
Expiration Date: 04/26/22
Approval Date: 09/29/16
Page 6 of 8
1
NAIL HOLES
PROFILE DRAWINGS
17"13"
Note: Available Top Surface Finishes
5. Complete tile brushed
6. Right half brushed (shown in drawing)
7. Left half brushed
8. No brush
APPROVED L
SAXON¥ 900 - SPLIT SHAKE
1-9/32" (Shake)
NOA No.: 16-0711.05
Expiration Date: 04/26/22
Approval Date: 09/29/16
Page 7 of 8
NAIL HOLES
APPROVED L
PROFILE DRAWINGS
17"
SAXONY 900- SHAKE
END OF THIS ACCEPTANCE
13"
1-9/32" (Shake)
NOA No.: 16-0711.05
Expiration Date: 04/26/22
Approval Date: 09/29/16
Page 8 of 8