Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FILE COPY /90S--0010 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: SIME RESIDENCE ler Name: RECEIVED Buili Street: WATERSONG WAY Per it Office: ST LUCIE COUNTY City, State, Zip: JENSEN BEACH, FL, t� 1 2019 J U N q Per it Number: - Owner: v Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce Cou ty: St. Lucie (Florida Climate Zone 2 ) Lucie Countv, Permittin 1. New construction or existing New (From Plans) 9. Wall Types (5189.2 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=19.0 4909.20 ft2 b. Frame - Wood, Adjacent R=13.0 280.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 5 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (4765.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=20.0 4765.00 ft2 6. Conditioned floor area above grade (ft2) 4765 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(1025.2 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: AHU 1 CLST 6 200 a. U-Factor: Sgl, U=0.30 1025.20 ft2 b. Sup: Attic, Ret: Attic, AH: AHU 2 CLST 6 130 SHGC: SHGC=0.20 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 48.5 SEER:17.00 b. Central Unit 25.4 SEER:17.30 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 34.0 COP:1.00 SHGC: b. Electric Strip Heat 17.0 COP:1.00 Area Weighted Average Overhang Depth: 5.599 ft. Area Weighted Average SHGC: 0.200 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (4765.0 sqft.) Insulation Area a. Raised Floor R=19.0 3634.00 ft2 b. Conservation features EF: 0.980 b. Slab -On -Grade Edge Insulation R=0.0 1131.00 ft2 None c. N/A' R= ft2 15. Credits None Glass/Floor Area: 0.215 Total Proposed Modified Loads: 128.07 PASS Total Baseline Loads: 166.10 I hereby certify that the plans and specifications covered by Review of the plans and viiE Sp��� this calculation are in compliance with the Florida Energy specifications covered by this ,. mm O Code. calculation indicates compliance �,yw ti,� =" ',•a with the Florida Energy Code. PREPARED BY: Before construction is completed, DATE: __ _6-17-19 this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as design is in pliance Florida Statutes. ✓;)� ': with the Florida Energy Code. Ofj OWNER/AGE T: BUILDING OFFICIAL: DATE: - DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with 11403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with 11402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 4/30/2019 4:34 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 10 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: SIME RESIDENCE Bedrooms: 5 Address Type: Street Address Building Type: User Conditioned Area: 4765 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: WATERSONG WAY Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: JENSEN BEACH, Family Type: Single-family FL, New/E)asting: New (From Plans) Comment: CLIMATE V Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 AHU 1 2887 28870 2 AHU 2 1878 18780 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 LIVING ROOM 458 4580 No 0 1 Yes Yes Yes 2 DINING 138 1380 No 0 1 Yes Yes Yes 3 KITCHEN 268 2680 Yes 0 1 Yes Yes Yes 4 HALLWAY 118 1180 No 0 1 No Yes Yes 5 AHU 1 CLST 15 150 No 0 1 Yes Yes Yes 6 ELEV 2ND FLR 25 250 No 0 1 Yes Yes Yes 7 BATH 3 84 840 No 0 1 Yes Yes . Yes 8 BEDROOM 3 234 2340 No 0 1 1 Yes Yes Yes 9 WIC 3 48 480 No 0 1 Yes Yes Yes 10 BEDROOM-2 249 2490 No 0 1 1 Yes Yes Yes 11 BATH 2 77 770 No 0 1 Yes Yes Yes 12 WIC 2 42 420 No 0 1 No Yes Yes 13 WASHER DRYER 48 480 No 0 1 Yes Yes Yes 14 BATH 1 66 660 No 0 1 Yes Yes Yes 15 AC STORAGE 50 500 No 0 1 Yes Yes Yes 16 ELEVATOR 1ST FL 25 250 No 0 1 Yes Yes Yes 17 STORAGE CLST 26 260 No 0 1 Yes Yes Yes 18 FOYER 238 2380 No 0 1 Yes Yes Yes 19 STAIRS 52 520 No 0 1 Yes Yes Yes 20 STORAGE 626 6260 No 0 1 Yes Yes Yes 21 M BATH 1.92 1920 No 0 1 Yes Yes Yes 4/30/2019 4:34 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 10 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 22 M TOILET 21 210 No 0 1 No Yes Yes 23 M WIC 159 1590 No 0 1 Yes Yes Yes 24 LAUNDRY 88 880 No 0 1 Yes Yes Yes 25 AHU 2 CLST 16 160 No 0 1 No Yes Yes 26 HALL 107 1070 No 0 1 No Yes Yes 27 ELEV 3RD FLR 25 250 No 0 1 Yes Yes Yes 28 WIC 5 48 480 No 0 1 Yes Yes Yes 29 BATH 5 84 840 No 0 1 Yes Yes Yes 30 BEDROOM 5 220 2200 No 0 1 1 Yes Yes Yes 31 BEDROOM 4 234 2340 No 0 1 1 Yes Yes Yes 32 BATH 4 77 770 No 0 1 Yes Yes Yes 33 WIC 4 42 420 No 0 1 No Yes Yes 34 MASTER BEDROO 477 4770 No 0 1 1 Yes Yes Yes 35 STAIRS 3RD FLR 88 880 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Raised Floor LIVING ROOM ---- -_-- 458 ft2 19 1 0 0 2 Raised Floor DINING ---_ ---- 138 ft2 19 1 0 0 3 Raised Floor KITCHEN ____ ---- 268 ft2 19 1 0 0 4 Raised Floor HALLWAY _-_- ---- 118 ft2 19 1 0 0 5 Raised Floor AHU 1 CLST ---- ____ 15 ft2 19 1 0 0 6 Raised Floor ELEV 2ND FLR ---- ____ 25 ft2 19 1 0 0 7 Raised Floor BATH 3 _ --- ____ 84 ft2 19 1 0 0 8 Raised Floor BEDROOM 3 ---_ ---- 234 ft2 19 1 0 0 9 Raised Floor WIC 3 -_-_ ---- 48 ft2 19 1 0 0 10Raised Floor BEDROOM 2 ---- ____ 249 ft2 19 1 0 0 11Raised Floor BATH 2 ---- ---- 77 ft2 19 1 0 0 12Raised Floor WIC 2 ---- ____ 42 ft2 19 1 0 0 13SIab-On-Grade Edge Insulation WASHER DRYE 14 ft 0 48 ft2 ---- 1 0 0 14SIab-On-Grade Edge Insulation BATH 1 lift 0 66 ft2 ___- 1 0 0 15SIab-On-Grade Edge Insulation AC STORAGE 10 ft 0 50 ft2 1 0 0 16SIab-On-Grade Edge Insulation ELEVATOR 1ST 5 ft 0 25 ft2 ---- 1 0 0 17Slab-On-Grade Edge Insulation STORAGE CLST 2 ft 0 26 ft2 ---_ 1 0 0 4/30/2019 4:34 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 10 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 18SIab-On-Grade Edge Insulation FOYER 20 ft 0 238 ft2 ---- 1 0 0 19SIab-On-Grade Edge Insulation STAIRS 4 ft 0 52 ft2 ---- 1 0 0 20SIab-On-Grade Edge Insulation STORAGE 49 ft 0 626 ft2 --e 1 0 0 2113aised Floor M BATH _--- ---- 192 ft2 19 1 0 0 22Raised Floor M TOILET _--- ---- 21 ft2 19 1 0 0 23Raised Floor M W IC ---- ---- 159 ft2 19 1 0 0 24Raised Floor LAUNDRY ---- ---- 88 ft2 19 1 0 0 25Raised Floor AHU 2 CLST ---- ---- 16 ft2 19 1 0 0 26Raised Floor HALL _--- ---- 107 ft2 19 1 0 0 27Raised Floor ELEV 3RD FLR _--- ---- 25 ft2 19 1 0 0 28Ra7ised Floor WIC 5 ---- ---- 48 ft2 19 1 0 0 29Raised Floor BATH 5 ---- ---- 84 ft2 19 1 0 0 30Raised Floor BEDROOM 5 ---- ---- 220 ft2 19 1 0 0 31Raised Floor BEDROOM 4 ---- ---- 234 ft2 19 1 0 0 32Raised Floor BATH 4 ---- ---- 77 ft2 19 1 0 0 33Raised Floor WIC 4 ---- ---- 42 ft2 19 1 0 '0 34Raised Floor MASTER BEDRO ---- ---- 477 ft2 19 1 0 0 35Raised Floor STAIRS 3RD FLR ---- ---- 88 ft2 19 1 0 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 5329 ft2 0 ft2 Light 0.4 No 0.9 No 20 26.6 ATTIC 1 V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 4765 ft2 N N 4/30/2019 4:34 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 10 FORM R405-2017 INPUT SUMMARY CHF-CKLI5T REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) LIVING ROOM 20 Blown 458 ft2 0.1 Wood 2 Under Attic (Unvented) DINING 20 Blown 138 ft2 0.1 Wood 3 Under Attic (Unvented) KITCHEN 20 Blown 268 ft2 0.1 Wood 4 Under Attic (Unvented) HALLWAY 20 Blown 118 ft2 0.1 Wood 5 Under Attic (Unvented) AHU 1 CLST 20 Blown 15 ft2 0.1 Wood 6 Under Attic (Unvented) ELEV 2ND FLR 20 Blown 25 ft2 0.1 Wood 7 Under Attic (Unvented) BATH 3 20 Blown 84 ft2 0.1 Wood 8 Under Attic (Unvented) BEDROOM 3 20 Blown 234 ft2 0.1 Wood 9 Under Attic (Unvented) WIC 3 20 Blown 48 ft2 0.1 Wood 10 Under Attic (Unvented) BEDROOM 2 20 Blown 249 ft2 0.1 Wood 11 Under Attic (Unvented) BATH 2 20 Blown 77 ft2 0.1 Wood 12 Under Attic (Unvented) WIC 2 20 Blown 42 ft2 0.1 Wood 13 Under Attic (Unvented) WASHER DRYE 20 Blown 48 ft2 0.1 Wood 14 Under Attic (Unvented) BATH 1 20 Blown 66 ft2 0.1 Wood 15 Under Attic (Unvented) AC STORAGE 20 Blown 50 ft2 0.1 Wood 16 Under Attic (Unvented) ELEVATOR 1ST 20 Blown 25 ft2 0.1 Wood 17 Under Attic (Unvented) STORAGE CLST 20 Blown 26 ft2 0.1 Wood 18 Under Attic (Unvented) FOYER 20 Blown 238 ft2 0.1 Wood 19 Under Attic (Unvented) STAIRS 20 Blown 52 ft2 0.1 Wood 20 Under Attic (Unvented) STORAGE 20 Blown 626 ft2 0.1 Wood 21 Under Attic (Unvented) M BATH 20 Blown 192 ft2 0.1 Wood 122 Under Attic (Unvented) M TOILET 20 Blown 21 ft2 0.1 Wood 23 Under Attic (Unvented) M WIC 20 Blown 159 ft2 0.1 Wood 24 Under Attic (Unvented) LAUNDRY 20 Blown 88 ft2 0.1 Wood 25 Under Attic (Unvented) AHU 2 CLST 20 Blown 16 ft2 0.1 Wood 26 Under Attic (Unvented) HALL 20 Blown 107 ft2 0.1 Wood 27 Under Attic (Unvented) ELEV 3RD FLR 20 Blown 25 ft2 0.1 Wood 28 Under Attic (Unvented) WIC 5 20 Blown 48 ft2 0.1 Wood 29 Under Attic (Unvented) BATH 5 20 Blown 84 ft2 0.1 Wood 30 Under Attic (Unvented) BEDROOM 5 20 Blown 220 ft2 0.1 Wood 31 Under Attic (Unvented) BEDROOM 4 20 Blown 234 ft2 0.1 Wood 32 Under Attic (Unvented) BATH 4 20 Blown 77 ft2 0.1 Wood 33 Under Attic (Unvented) WIC 4 20 Blown 42 ft2 0.1 Wood 34 Under Attic (Unvented) MASTER BEDRO 20 Blown 477 ft2 0.1 Wood 35 Under Attic (Unvented) STAIRS 3RD FLR 20 Blown 88 ft2 0.1 Wood WALLS Adjacent Cavity Width Space Height Sheathing Framing Solar Below 1 N Exterior Concrete Block - Int InsuLIVING ROO 19 18 0 10 0 180.0 ft2 4 0 0.4 0 2 E Exterior Concrete Block - Int InsuLIVING ROO 19 22 0 10 0 220.0 ft2 4 0 0.4 0 _ 3 SE Exterior Concrete Block- Int InsuLIVING ROO 19 9 11 10 0 99.2 ft2 4 0 0.4 0 _ 4 S Exterior Concrete Block - Int InsuLIVING ROO 19 8 0 10 0 80.0 ft2 4 0 0.4 0 5 S Exterior Concrete Block- Int Insul DINING 19 14 0 10 0 140.0 ft2 4 0 0.4 0 4/30/2019 4:34 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 10 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Ornt Adjacent STo %A/mll Typepace Cavity Width Height Sheathing Framing Solar Below 6 N Exterior Concrete Block - Int Insul KITCHEN 19 13 0 10 0 130.0 ft2 4 0 0.4 0 7 S Exterior Concrete Block - Int InsuAHU 1 CLST 19 3 0 10 0 30.0 ft2 4 0 0.4 0 8 S Exterior Concrete Block - Int InSdELEV 2ND FL 19 5 0 10 0 50.0 ft2 4 0 0.4 0 9 S Exterior Concrete Block - Int Insul BATH 3 19 5 0 10 0 50.0 ft2 4 0 0.4 0 10 S Exterior Concrete Block - Int InsuBEDROOM 3 19 15 0 10 0 150.0 ft2 4 0 0.4 0 _ 11 W Exterior Concrete Block - Int InsuBEDROOM 3 19 14 0 10 0 140.0 ft2 4 0 0.4 0 12 S Exterior Concrete Block - Int Insul WIC 3 19 8 0 10 0 80.0 ft2 4 0 0.4 0 _ 13 N Exterior Concrete Block - Int InsuBEDROOM 2 19 15 0 10 0 150.0 ft2 4 0 0.4 0 14 W Exterior Concrete Block - Int InsuBEDROOM 2 19 15 0 10 0 150.0 ft2 4 0 0.4 0 15 N Exterior Concrete Block - Int Insul BATH 2 19 11 0 10 0 110.0 ft2 4 0 0.4 0 16 E Exterior Concrete Block - Int Insdi1/ASHER DR 19 6 -0 10 0 60.0 ft2 4 0 0.4 0 17 S Exterior Concrete Block - Int Insta}VASHER DR 19 8 0 10 0 80.0 ft2 4 0 0.4 0 18 S Exterior Concrete Block - Int Insul BATH 1 119 11 0 10 0 110.0 ft2 4 0 0.4 0 19 S Exterior Concrete Block - Int InsuAC STORAG 19 10 0 10 0 100.0 ft2 4 0 0.4 0 20 S Exterior Concrete Block - Int InsLELEVATOR 1 19 5 0 10 0 50.0 ft2 4 0 0.4 0 _ 21 N Exterior Concrete Block - Int InsuSTORAGE C 19 2 0 10 0 20.0 ft2 4 0 0.4 0 22 S Exterior Concrete Block - Int Insul FOYER 19 14 0 10 0 140.0 ft2 4 0 0.4 0 _ 23 W Exterior Concrete Block - Int Insul FOYER 19 6 0 10 0 60.0 ft2 4 0 0.4 0 24 W Garage Frame - Wood FOYER 13 4 0 10 0 40.0 ft2 0 0.25 0.4 0 25 NW Garage Frame - Wood FOYER 13 4 0 10 0 40.0 ft2 0 0.25 0.4 0 26 N Garage Frame - Wood FOYER 13 8 0 10 0 80.0 ft2 0 0.25 0.4 0 27 N Exterior Concrete Block - Int Insul STAIRS 19 4 0 10 0 40.0 ft2 4 0 0.4 0 28 W Garage Frame - Wood STAIRS 13 12 0 10 0 120.0 ft2 0 0.25 0.4 0 29 N Exterior Concrete Block - Int Insul STORAGE 19 26 0 10 0 260.0 ft2 4 0 0.4 0 30 E Exterior Concrete Block - Int Insul STORAGE 19 23 0 10 0 230.0 ft2 4 0 0.4 0 _ 31 N Exterior Concrete Block - Int Insul M BATH 19 16 0 10 0 160.0 ft2 4 0 0.4 0 _ 32 E Exterior Concrete Block - Int Insul M BATH 19 12 0 10 0 120.0 ft2 4 0 0.4 0 _ 33 S Exterior Concrete Block - Int Insul M BATH 19 10 0 10 0 100.0 ft2 4 0 0.4 0 34 N Exterior Concrete Block- Int Insul M W IC 19 15 0 10 0 150.0 ft2 4 0 0.4 0 _ 35 N Exterior Concrete Block - Int Insul LAUNDRY 19 7 0 10 0 70.0 ft2 4 0 0.4 0 _ 36 S Exterior Concrete Block - Int InsdELEV 3RD FL 19 5 0 10 0 50.0 ft2 4 0 0.4 0 37 S Exterior Concrete Block- Int Insul WIC 5 19 8 0 10 0 80.0 ft2 4 0 0.4 0 38 S Exterior Concrete Block - Int Insul BATH 5 19 5 0 10 0 50.0 ft2 4 0 0.4 0 39 S Exterior Concrete Block - Int InsuBEDROOM 5 19 14 0 10 0 140.0 ft2 4 0 0.4 0 40 W Exterior Concrete Block - Int InsuBEDROOM 5 19 14 0 10 0 140.0 ft2 4 0 0.4 0 41 N Exterior Concrete Block - Int InsuBEDROOM 4 19 14 0 10 0 140.0 ft2 4 0 0.4 0 42 W Exterior Concrete Block- Int InsuBEDROOM 4 19 15 0 10 0 150.0 ft2 4 0 0.4 0 43 N Exterior Concrete Block - Int Insul BATH 4 19 11 0 10 0 110.0 ft2 4 0 0.4 0 _ 44 E Exterior Concrete Block - Int InsuMASTER BE 19 17 0 10 0 170.0 ft2 4 0 0.4 0 _ 45 S Exterior Concrete Block - Int InsuMASTER BE 19 29 0 10 0 290.0 ft2 4 0 0.4 0 46 N Exterior Concrete Block - Int InsLSTAIRS 3RD 19 8 0 10 0 80.0 ft2 4 0 0.4 0 4/30/2019 4:34 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 6 of 10 FORM R405-2017 INF'U 1 5UMMAKY IL;Hh ;KL151 Kt=F'UK I DOORS # Ornt Door Type Space Storms U-Value Width Height Area I Ft In Ft In 1 E Insulated WASHER DR None .27 2 8 8 21.3 ft2 I WINDOWS I Orientation shown is the entered. PrODosed orientation. V # Ornt Wall ID Frame Panes NFRC U-Factor SHGC Imp Area Overhang Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Single Yes 0.3 0.2 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None 2 E 2 Vinyl Low-E Single Yes 0.3 0.2 N 144.0 ft2 7 ft 0 in 1 ft 4 in None None 3 SE 3 Vinyl Low-E Single Yes 0.3 0.2 N 48.0 ft2 7 ft 0 in 1 ft 4 in None None 4 S 5 Vinyl Low-E Single Yes 0.3 0.2 N 6.0 ft2 2 ft 0 in 1 ft 4 in None None 5 S 5 Vinyl Low-E Single Yes 0.3 0.2 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None 6 N 6 Vinyl Low-E Single Yes 0.3 0.2 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None 7 S 9 Vinyl Low-E Single Yes 0.3 0.2 N 6.2 ft2 2 ft 0 in 1 ft 4 in None None 8 S 10 Vinyl Low-E Single Yes 0.3 0.2 N 30.0 ft2 2 ft 0 in 1 ft 4 in None None 9 W 11 Vinyl Low-E Single Yes 0.3 0.2 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None 10 W 11 Vinyl Low-E Single Yes 0.3 0.2 N 20.0 ft2 5 ft 0 in 1 ft 4 in None None 11 N 13 Vinyl Low-E Single Yes 0.3 0.2 N 30.0 ft2 2 ft 0 in 1 ft 4 in None None 12 W 14 Vinyl Low-E Single Yes 0.3 0.2 N 15.0 ft2 5 ft 0 in 1 ft4 in None None 13 W 14 Vinyl Low-E Single Yes 0.3 0.2 N 20.0 ft2 5 ft 0 in 1 ft 4 in None None 14 N 15 Vinyl Low-E Single Yes 0.3 0.2 N 4.0 ft2 2 ft 0 in 1 ft 4 in None None 15 S 22 Vinyl Low-E Single Yes 0.3 0.2 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None 16 W 23 Vinyl Low-E Single Yes 0.3 0.2 N 48.0 ft2 12 ft 0 in 1 ft 4 in None None 17 N 27 Vinyl Low-E Single Yes 0.3 0.2 N 18.0 ft2 2 ft 0 in 1 ft 4 in None None 18 N 29 Vinyl Low-E Single Yes 0.3 0.2 N 30.0 ft2 2 ft 0 in 1 ft 4 in None None 19 E 30 Vinyl Low-E Single Yes 0.3 0.2 N 144.0 ft2 10 ft 0 in 1 ft 4 in None None 20 E 32 Vinyl Low-E Single Yes 0.3 0.2 N 40.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None 21 N 34 Vinyl Low-E Single Yes 0.3 0.2 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None 22 N 35 Vinyl Low-E Single Yes 0.3 0.2 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None 23 S 37 Vinyl Low-E Single Yes 0.3 0.2 N 6.0 ft2 2 ft 0 in 1 ft 4 in None None 24 S 38 Vinyl Low-E Single Yes 0.3 0.2 N 6..0 ft2 2 ft 0 in 1 ft 4 in None None 25 S 39 Vinyl Low-E Single Yes 0.3 0.2 N 30.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 26 W 40 Vinyl Low-E Single Yes 0.3 0.2 N 15.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 27 W 40 Vinyl Low-E Single Yes 0.3 0.2 N 20.0 ft2 5 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 28 N 41 Vinyl Low-E Single Yes 0.3 0.2 N 30.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 29 W 42 Vinyl Low-E Single Yes 0.3 0.2 N 15.0 ft2 5 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 30 W 42 Vinyl Low-E Single Yes 0.3 0.2 N 20.0 ft2 5 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 31 N 43 Vinyl Low-E Single Yes 0.3 0.2 N 4.0 ft2 2 ft 0 in 1 ft 4 in None None 32 E 44 Vinyl Low-E Single Yes 0.3 0.2 N 96.0 ft2 10 ft 0 in 1 ft 4 in None None 33 S 45 Vinyl Low-E Single Yes 0.3 0.2 N 45.0 ft2 2 ft 0 in 1 ft 4 in None None 34 N 46 Vinyl Low-E Single Yes 0.3 0.2 N 30.0 ft2 2 ft 0 in 1 ft 4 in None None 4/30/2019 4:34 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 7 of 10 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 600 ft2 600 ft2 28 ft loft 13 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse r Proposed ACH(50) .000445 5559.2 305.19 573.96 .3446 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity -Block Ducts 1 2 Electric Strip Heat/ Electric Strip Heat/ None None COP:1 34 kBtu/hr 1 COP:1 17 kBtu/hr 2 sys#1 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 2 Central Unit Central Unit/ Split Split SEER: 17 48.5 kBtu/hr 1455 cfm 0.8 1 SEER: 17.3 25.4 kBtu/hr 762 cfm 0.8 2 sys#1 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None AHU 1 CLST 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS # ---- Supply---- Location R-Value Area ---- Return ---- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 2 Attic 6 200 ft2 Attic 6 130 ft2 Attic Attic 20 ft2 Default Leakage AHU 1 CLS (Default) c(Default) c 13 ft2 Default Leakage AHU 2 CLS (Default) c(Default) c 1 1 2 2 4/30/2019 4:34 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 8 of 10 FORM R405-2017 . INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat: N Ceiling Fans: CoolingJan HeatinJan Feb Feb Mar Mar Apr APr May [X] May [ Jun ] Jun Jul rj Jul Au AuSep Se ri [ ] Oct [ ] Oct Nov Nov Dec Dec Ventin Jan Feb Mar A r [ L Ma [ ] Jun Jul [ Aug l Se [X] Oct X X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (W D) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 4/30/2019 4:34 PM EnergyGauge® USA Section R405.4.1 Compliant Software IPage 9 of 10 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 LIVING ROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 DINING Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 HALLWAY Default(8 Ibs/sq.ft. ft2 ft 0.3 AHU 1 CLST Default(8 Ibs/sq.ft. ft2 ft 0.3 ELEV 2ND FLR Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 Default(8lbs/sq.ft. ft2 ft 0.3 WIC 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 WASHER DRYER Default(8lbs/sq.ft. ft2 ft 0.3 BATH 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 AC STORAGE Default(8 Ibs/sq.ft. ft2 ft 0.3 ELEVATOR 1ST FL Default(8 Ibs/sq.ft. ft2 ft 0.3 STORAGE CLST Default(8 lbs/sq.ft. ft2 ft 0.3 FOYER Default(8 Ibs/sq.ft. ft2 ft 0.3 STAIRS Default(8 Ibs/sq.ft. ft2 ft 0.3 STORAGE Default(8 Ibs/sq.ft. ft2 ft 0.3 M BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 M TOILET Default(8 Ibs/sq.ft. ft2 ft 0.3 M WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 Ibs/sq.ft. ft2 ft 0.3 AHU 2 CLST Default(8 Ibs/sq.ft. ft2 ft 0.3 HALL Default(8 Ibs/sq.ft. ft2 ft 0.3 ELEV 3RD FLR Default(8lbs/sq.ft. ft2 ft 0.3 WIC 5 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 5 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 5 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 MASTER BEDROO Default(8 Ibs/s .ft. ft2 ft 0.3 STAIRS 3RD FLR Name: Signature: Rating Compant: Date: 4/30/2019 4:34 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 10 of 10