Loading...
HomeMy WebLinkAbout20378.6 5V CRIMP2160 SW Poma Drive Palm City, FL 34990 _._.... 772) 872-8034 Compliant with Florida Building Code 2017 (6th ed.) Compliant with Florida Product Approval Rule # 61G20-3 Compliant: Keystone Certifications Product: 5 V Crimp 26GA Metal Roofing Panel Corrosion Resistant FBC Sec. 1507.4.3 Yield strength: 40ksi Steel Attached to min.1S/32" plywood or Wood Deck w/ min. Attached 24" 0.42 specific gravity with screws. 24" Coverage Coverage Rib Height 3/8" Corrosion Resistant Compliant: FBC Sec. 1506,1507 Fastener for Method 1 Attachment # 9-iS x 1"Hex Head w/EPDM Banded Steel Washer to penetrate 3/16" thru wood decking Fastener for Method 2 Attachment # 945 x 1" Hex Head w/EPDM Bonded Steel Washer to penetrate 3/16" thru 15/32"rein. plywood deck or 5/8" into wood plank Underlayrnent: To be compliant with Fac Sec.1507.1.1 Slope: Shall be in compliance with FBC Sec. 1507. i. Install ©°tails. Table_A V Allowable Loads �� METHOD 1 � METHOD 2 i ASTENER PLA ENT DESIGN PRESSURE* _ _ _ i -8S PSF-114.25 PSF METHOD ! IN RIB PEAKS R©W SPACING it Q.C. 12" O,C. METHOD 2IN PANEL FLATS FASTENER SPACING 11" O.Gn D.C. i =5Ep INSTALL QRAwiNG5 FASTENERSi2E; ? #€9 *ALLOWABLE DESIGN PRESSURE MARGIN QF _2TO I I Reference Data: HURRICANE PEST LA8 #TST ID: IS27 SAS 125-03 Test # 0223-0307--01; METHOD 1 (UL 1897-04') TAS-12S-03 Test # 0223-0517-06, METHOD 2 EQUIVALENCY UL 1897-04 IS EQUIVALENT To UL 1697-12 TEST STANDARD DESIGN PRESSURE SAFETY MARIGIN 2.1 Certificate of Independence: Locke Bowden, P.E. does not have, not will acquire a financial interest in any company manufacturing or distributin products under this evaluation.;�,4 t s t+ T s i fr Locke Bowden, P.E. is not owned, operated, or controlled by any company, manufacturer, or distributin-go Djad-os deft report.• Compliance Statement: These products herein evaluated have demonstrated compliance with the Florida Building Code 2017 6a' ed., with referenced documents submitted. Limitations. 1. Underlayment to be compliance with current Florida Building Code 2017 611,ed-• Section 1507.1,1 2. Products are compliant for State of Florida product approval per Rule 61G20-3 3. Compliance Method; 1-D 4. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. S. All support framing compliantw/ Florida Building Code 2017, Chapters 22 for Steel, 23 for Wood and 16 for Structural Loading. Design of supportand attachment to the framing is outside the scope of this evaluation. 6. Rule 61G20-3 allows for engineering analysis by registered/licensed others for "project specific approval" by local authorities, authorized by the code, and is the responsibility of others, 7. This report does not imply warranty, installation, recommended product use outside of this report. Fsstr�urs- - s 2" or areatss PM %,Ood. or "lo d V!artk Fasteners - -15 Hex -Head Scre,vs Mh 5 -Gimp" Roof Partei EPDM Bwded Steel flashers is - 35;32" or greater Ply,,Wood. or -'Wood plank