Loading...
HomeMy WebLinkAboutRiordan 3Business & Professional Regulation BCIS Home I Log In I User Registration Hot TopJ71 Submit Surcharge Stats & Facts Publications I FBC Staff BCIS Site Map Links Search Florida li ProductApproval R, USER: Publle User Gi•J.JF�Yla.kti':I Product Approval Menu > Product or Application Search > Application Ust > Application Detail FL # FL6332-R8 Application Type Revision Code Version 2017 Application Status Approved Comments Archived ❑ Product Manufacturer ICP Adhesives & Sealants, Inc. Address/Phone/Email 12505 NW 44th Street Coral Springs, FL 33065 (888) 774-1419 Ext 201 rylipelkonen@icpadhesives.com Authorized Signature Riku Ylipelkonen rylipelkonen@icpadhesives.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Roof Tile Adhesives Compliance Method Evaluation Report from a Florida Registered Architect ora Licensed Florida Professional Engineer ❑ Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE -59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 02/07/2021 Validated By John W. Knezevich, PE 0 Validation Checklist - Hardcopy Received Certificate of independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FL6332 R8 COI 2017 01 COI Nieminen,pdf standard SSTD 11 Product Approval Method Method 1 Option D Year 1997 Date Submitted 10/12/2017 Date Validated 10/14/2017 Date Pending FBC Approval 10/17/2017 Date Approved 12/12/2017. FL xF Model, Number or Name 6332.1 ICP' Adhesives Polyset AH -160 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +n/a/-178 other: 1.) The design pressure limitation in this application refers to hip and ridge tiles in one configuration. Refer to Table 2 of ER for all hip and ridge file limitations. 2.) Field tiles are designed based on overturning moment resistance. Refer to Table 1 of ER for field tile limitations. 3.) Refer to ER Sections 5 for other Limitations of Use. Description Dual component expanding polyurethane roof tile adhesive Installation Instructions Fl6332 R8 II 2017 10 FINAL ER ICP AH160 FL6332- R8.Odf Verified By: Robert Nieminen PE -59166 Created by Independent Third Party: Yes Evaluation Reports FL6332 R8 AE 2017 10 FINAL ERCP AH160 FL6332- R8, Ddf Created by Independent Third Party: Yes Back Next Contact Us :: 7601 Blair Stone Road Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :; Accessibility Statement ;: Refund Statement Under Florida law, email addresses are public records. If you do not want your e -mall address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275 (1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here.. Product Approval Accepts; ®Wnr® Credit Card Safe ��TRINITYJMD EVALUATION REPORT ICP Adhesives and Sealants, Inc. 12505 NW 44th Street Coral Springs, FL 33065 (888) 774-1419 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT 13 OXFORD, CT 06478 (203) 262-9245 Evaluation Report 02768.03.06-R8 FL6332-R8 Date of Issuance: 08/08/2008 Revision 8:10/12/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: ICP Adhesives Polyset® AH -160 LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinityi ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 9. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E_ on 10/12/2017. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Exterior Research & Design, LLC. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity) ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. �I TRINITY I ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Roof Tile Adhesives Compliance Statement: ICP Adhesives Polyset® AH -160, as produced by ICP Adhesives and Sealants, Inc., has demonstrated compliance with the 6th Edition (2017) Florida Building Code through testing in accordance with the Standards set forth herein. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Sections Property Standard Year 1504.2.1.1 Overturning resistance SSTD 11 1997 3. REFERENCES: 9ROY Examination Reference Date ERD (TST 6049) Static Uplift — SSTD 11 P39740.02.12 02/20/2012 ERD (TST 6049) Static Uplift—SSTD 11 P39740.11.13 -R1 01/02/2015 ICC -ES (EVL2396) 2012 IBC Compliance ESR -1709 12/01/2016 Miami -Dade (CER 1592) HVHZcompliance 17-0322.03 04/27/2017 PRI (TST 5878) Static Uplift—SSTD 11 ECM -001-02-01 09/21/2001 PRI (TST 5878) Static Uplift— SSTD 11 PFI -006-02-01 05/09/2005 PRI (TST 5878) Static Uplift—SSTD 11 PFI -006-02-02 05/09/2005 PRI (TST 5878) Static Uplift —SSTD 11 PFI -007-02-01 10/11/2005 PRI (TST 5878) Static Uplift =SSTD 11 PFI -008-02-04 02/21/2006 PRI (TST 5878) Static Uplift—SSTD 11 PFI -009-02-03 02/21/2006 PRI (TST 5878) Static Uplift—SSTD 11 TGRI-001-02-03 10/30/2006 PRI (TST 5878) Static Uplift—SSTD 11 TGRI-001-02-03 10/30/2006 PRI (TST 5878) Static Uplift —SSTD 11 PFPI-010-02-01 12/07/2006 PRI (TST 5878) Static Uplift — SSTD 11 PFPI-011-02-01 12/07/2006 PRI (TST 5878) Static Uplift-SSTD 11 PFPI-012-02-01 12/07/2006 PRI (TST 5878) Static Uplift—SSTD 11 PFPI-013-02-01 12/07/2006 PRI (TST 5878) Static Uplift — SSTD 11 PFPI-014-02-01 12/07/2006 PRI (TST 5878) Static Uplift—SSTD 11 ECM -003-02-01 06/13/2008 PRI (TST 5878) Static Uplift — SSTD 11 ECM -004-02-01 06/13/2008 PRI (TST 5878) Static Uplift — SSTD 11 ECM -005-02-01 06/13/2008 PRI (TST 5878) Static Uplift — SSTD 11 ECM -006-02-01 06/13/2008 PRI (TST 5878) Static Uplift — SSTD 11 ECM -007-02-01 06/13/2008 PRI (TST 5878) Static Uplift—SSTD 11 ECM -008-02-01 06/13/2008 UL LLC (QUA 9625) Quality Assurance Service Confirmation Exp. 06/05/2018 4. PRODUCT DESCRIPTION: 4.1 ICP Adhesives Polyset® AH -160 is a two -component expanding polyurethane roof tile adhesive that is mixed and dispensed from a dispensing system provided by ICP Adhesives and Sealants, Inc. The components are available in refillable tanks or disposable cylinders (ICP Adhesives ProPack" 30 & 100). S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. Exterior Research and Design, LLC. Evaluation Report 02768.03.06-118 Certificate ofAuthorization #9503 6EDITION (2017) FBC NON-HVHZ EVALUATION F1.6332-118 ICP Adhesives Polyset® AH -160; (888) 774-1419 Revision 8:10/12/2017 Page 2 of 9 �TRINITYJ ERD 5.3 Fire classification is not part of this evaluation. Refer to a current Roofing Materials Directory for fire ratings of this product and FBC 1505.2. 5.4 ICP Adhesives Polyset® AH -160 can be used with flat, low and high profile tiles or any rigid, discontinuous roof assembly having a current Florida Statewide Product Approval or approved on a local -level by the Authority Having Jurisdiction. 5.5 Minimum underlayment shall be per FRSA/TRI April 2012 (04-12) or having a current Florida Statewide Product Approval or approved on a local -level by the Authority Having Jurisdiction for use with ICP Adhesives Polyset® AH -160. 5.6 Field tiles, meeting the limitations of FBC 1609.5.9, using ICP Adhesives Polyset® AH -160 are limited to projects having an Aerodynamic Uplift Moment (M.), determined in accordance with FBC 1609.5.3 or Tables 2A and 213 of FRSA/TRI April 2012 (04-12), not greater than the following Allowable Overturning Moment values. Refer to Section 10 and ICP Adhesives and Sealants, Inc. published installation instructions for Adhesive Paddy Placement details. -" TABS 1 FIE67aLEs IN 1CP ADI EsluEs'Po rsET®AH 160 ALLOWABLE OuERTURNING MOMENT PERpORMANCE DATA .:. �� ZTOIMAR!i(NOFSAFECf'AIREADYAPPl1EDFORIND�PENDEM(S/NGLEORCbNlINUOUSPADDK�PIACEMENr ''/1TQ,I;MAIjGIN�OFSAFETYALREI)DYAPP,UEDFOR?INTERDEPENDENT (TWO, PADDY]PIACEMENI,. - " '' .. Tile (FBC 1609.5.3) Allowable Adhesive Paddy Placement Overturning Type Profile Moment (ft-lbf) Independent; Single Paddy, Medium (2x7 -inch, —30 gram) 60 Clay Flat Independent; Single Paddy, Large (2x10 -inch, —45 gram) 112 Concrete Interdependent; Two Paddy (4x4 -inch on underlayment, 2x4 -inch at the overlap) 54 Independent; Single Paddy, Medium (2x7 -inch, —30 gram) 39 Clay Low/ Independent; Single Paddy, Large (2x10 -inch, —54 gram) 67 te Concrete Medium Interdependent; Two Paddy (4x4 -inch on underlayment, 2x4 -inch at file overlap) 58 Clay High Independent; Single Paddy, Large (2x10 -inch, —45 gram) 134 Independent; Single Paddy, Medium (2x7 -inch, —30 gram) 65 Clay High Independent; Single Paddy, Large (2x10 -inch, —63 gram) 109 Concrete Interdependent; Two Paddy (44 -inch on underlayment, 2x4 -inch at the overlap) 40 Clay Barrel 2x10 -inch x ^35 gram for pans; 2 @ 1x10 -inch x —17 gram for cap 147 Concrete Barrel 2x10 -inch x ^35 gram for pans; 2 @ 1x10 -inch x —17 gram for cap 107 Clay Cap atop 2x Independent: Continuous Paddy ('"34 gram/ft) 135 stringer Concrete Cap atop 2x Independent: Continuous Paddy ('" 34 gram/ft) 116 stringer Cap atop 2x Interdependent: 105 Clay stringer Head: One (1) #10 x 2%" screw; Overlap: l x 6 inch (^'10.5 gram) Cap atop 2x Interdependent: 76 Concrete stringer I Head: One (1) #10 x 2%' screw; Overlap:1 x 6 inch ("'10.5 gram) 5.6.1 Data in Table 1 relates to installation over a '30/90' underlayment system, as detailed in the FRSA/TRI April 2012 (04-12). Alternate underlayment systems include those having a current Florida Statewide Product Approval and/or approved on a local -level by the Authority Having Jurisdiction specifically for use with ICP Adhesives Polyset® AH -160. 5.6.2 Tile roof systems using tile types or profiles other than those listed above acquiring acceptance for use with ICP Adhesives Polyset® AH -160 shall be tested in accordance with SSTD 11 or Testing Application Standard TAS 101. For the interdependent two -paddy method, an additional 2 -to -1 margin above that specified in SSTD 11 or Testing Application Standard TAS.101 shall be applied in determining the 'allowable overturning moment'. Exterior Research and Design, U.C. Evaluation Report 02768.03.06•R8 certificate o/Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-R8 ICP Adhesives Polyset® AH -160; (888) 774-1419 Revision 8:10/12/2017 Page 3of9 \,,�TRINITYJERD 5.7 Hip and ridge tiles using ICP Adhesives Polyset® AH -160 are limited to projects having hip/ridge design pressure requirements, determined in accordance with Table 1A of FRSA/TRI April 2012 (04-12), not greater than the following values. Refer to ICP Adhesives and Sealants, Inc. published installation instructions for Adhesive Paddy Placement details. ;TABLE 2 HIP & RIDGE TILES,IN ICPADHESIVES.POLYSEf®AH 160 ALLOW ABLE;U0LI0TREsISTANM. ERFORNIANCE0", 2 T01 MARGINOF SAFEYYALREADYAPPUED FOR /MDEPEDDY PLACEMENT 44. 4 T01,INARGINOFSAFETYALREAOYAPPOMFOR INTERDEPENDFNFPLACEMENTM Allowable Tile Substrate Attachment Method Design Pressure Ipso Clay 2x PT ridge board Independent: Continuous Paddy (-34 gram/ft) 116 Concrete 2x PT ridge board Independent: Continuous Paddy (— 34 gram/ft) 107 Interdependent: Head: One (1) #10 x 2%=' screw; 90 Clay 2x PT ridge board Overlap:1 x 6 inch (-10.5 gram) Concrete 2x PT ridge board Interdependent: Head: One (1) #10 x 2%" screw; 56 Overlap:1 x 6 inch (~10.5 gram) Clay or Hip & Ridge Channel Metal (FL5374): independent: Continuous Paddy (^34 gram/ft) 169 Concrete galvanized only Clay or Trim Lock'" (FL5374): aluminum, Independent: Continuous Paddy (" 34 gram/ft) 173 Concrete galvanized, Galvalume0 or stainless steel Clay or Trim Lock"' Plus (FL5374): aluminum, Independent: Continuous Paddy 34 gram/ft) 178 Concrete galvanized, Galvalume® or stainless steel Clay Top Notch (FL8095) Independent: Continuous Paddy (" 32 gram/ft) 125 Concrete Top Notch (FL8095) Independent: Continuous Paddy (" 32 gram/ft) 146 6. INSTALLATION: 6.1 ICP Adhesives Polyset® AH -160 and the tile roof assembly shall be installed in accordance with FRSA/TRI April 2012 (04-12) and ICP Adhesives and Sealants, Inc, published installation instructions, subject to the limitations outlined in Section 5. 6.2 Hip and ridge.boards or hip/ridge metal shall be installed in accordance with the FRSA/TRE April 2012 (04-12). Proprietary hip and ridge metal shall be installed in accordance with the manufacturer's Florida Product Approval. 6.3 Installation shall be performed by applicators who hold a valid Qualified Applicator Card presented by ICP Adhesives and Sealants, Inc. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. S. MANUFACTURING PLANTS: Tomball, TX 9. QUALITY ASSURANCE ENTITY: UL, LLC. — QUA9625; (847) 664-3623; LeAnna.Gradecki@ul.com Exterior Research and Design, LLC. Evaluation Report 02768.03.06-118 Certificate ofAuthorizationl19503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION F1.6332-118 ICP Adhesives Polyset® AH -160,(888) 774-1419 Revision 8:10/12/2017 Page 4 of 9 TRINITY � ERD 10. PADDY PLACEMENT DETAILS (FROM ICP ADHESIVES AND SEALANTS, INC. PUBLISHED LITERATURE): 10.1 Independent, Medium Paddy: Nail through plastic cement Paddy (Beneath Tile) (when required) Underlayment ° `I- o 7 in2iin. Batten's optional ° Eave Course o ° loin. Fascia tin Eave Closure Flat/Low PrAle Tile Nail through plastic cement (when required) Paddy (Beneath Tile) Underlayment Y lin. 2i In. Battens optional loin 2 in. Eave Closure Eave Course Fascia Medium Profile Tile Nail through plastic ce (when required) Paddy (Beneath Tile) IUnderiayment W 7in.�Zin. Battens optional Eave Course Fascia Weephole t o in.2 in. Eave closure Drip edge High Profile Tile Exterior Research and Design, LLC. Evaluation Report 02768.03.06-R8 Certificate of Authorization 119503 6T" EDITION (2017) FBC NON-HVH2 EVALUATION FL6332-R8 ICP Adhesives Polyset® AH -160; (888) 774-1419 Revision 8:10/12/2017 Page S of 9 10.2 Independent, Large Paddy: Nail through plastic cemer (when required) Underlayment 1 o optional o arse 0 o 7Uin Paddy (Beneath Tile) Flat/Low Profile Tile � TRINITY I ERD Nail through plastic cement (when required) Paddy (Beneath Tile) Underlayment r 1 o in.x 2 in. de Battens optional 10 in. 2i Eave Closure Eave Course Fascia Medium Profile Tile Nail through piasticce (when required) Paddy (Beneath Tile) IUnderlayment W 2on.wide Battens o \ a optional Eave Course Fascia weephole 10 in.2 inEave closure . Drip edge 111111 1 High Profile Tile i Exterior Research and Design, LLC. Evaluation Report 02768.03.06-118 Certificate ofAuthorization #9503 6EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-R8 ICP Adhesives Polyset® AH -160; (888) 774-1419 Revision 8:10/12/2017 Page 6 of 9 10.3 Interdependent, Two Paddy: Nail through plastic cement Paddy (between tiles) (when required) ° Battens optional o Paddy(undertile) Single paddy ontopoftile �4x 4 in. Single paddy undertil Single paddy on underlayment 2 x 4 in. 0 0 10 in. Fascia 2 in. Eave Closure Flat/Low Profile Tile --,�TRINITYJERD Nail through plastic cement Single paddy under tile (when required) Paddy (between tiles) Battens Paddy (under tile) Single paddy (optional Single paddy on top of the \ y x4in. top oftile x4in. Single paddy on Fascia underlayment weephole 10 in. 2 in. = Eave Closure Eave Course Fascia Medium Profile Tile Nail through plastic ce Sing le paddy under tile (when required) Paddy (between tiles) Battens ° ° optional Paddy (under life) Single paddy on underlayment 4 x 4 in. Single 2x4in. paddyon top oftile Eave Course Fascia weephole Eave closure t0 in.2io Drip edge High Profile Tile Exterior Research and Design, LLC. Evaluation Report 02768.03.06-118 Certiftate ofAuthorization A9503 6TM EDITION (2017) FBC NON-HVH2 EVALUATION FL6332-118 ICP Adhesives Polysete AH -160; (888) 774-1419 Revision 8:10/12/2017 Page 7 of 9 10.4 Two Piece Barrel (Cap & Pan) Tile: 1) Place enough adhesive to achieve 6S to 7o :in contact with the pan tile. 2) Tum Covera. upside down. Place adhesive 112 In. to t inch in from outside edge of cover tile. Install cover tile. Ensure 20 to 25 sq. in. contact area on I :each side of cover We. Underlayment Eave closure (meter shown) Steep pitch applications --- -.- Fascia Board-- `J Remove top portion of the eave course cover tile. Abut to second course of pan tlles.Ensure eave end of pan and cover tiles are flush at eave line. Two Piece Barrel - High Prof)IeTile 10.5 Hip and Ridge (independent placement): w bead of[CP Pot}�et�AFi-t60 rosy be applied above ilu fidd b7e sar&ce oaboth sides of the hiplddge board or gahtlized acetal fraum to provide Weathetbloeking. To attach hipMdg ales. a bead of1C11 Po41s,-42AH•160nny be applied domva the center of Ore hiphWa board Or salved frame. \,(TRINIIY I ERD Exterior Research and Design, I.I.C. Evaluation Report 02768.03.06-R8 c:ertiffcate cifAuthorization #9503 bra EDITION (2017) FBC NON-HVHZ EVAWATION FL6332-R8 ICP Adhesives Polyset® AH -160; (888) 774-1419 Revision 8:10/12/2017 Page 8 of 9 -,l I RINITY ERD 10.6 Hip and Ridge (interdependent placement): - END OF EVALUATION REPORT - Exterior Research and Design, I.I.C. Evaluation Report 02768.03.06-R8 certyicate ofAuthorization X19503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION F1.6332 -R8 ICP Adhesives Polyset® AH -160; (888) 774-1419 Revision 8:10/12/2017 Page 9 of 9