Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Windload
WINDLOADCALC.com Nominal 170 131.7 II Hurricane D Internal Pressure Enclosed Company Height above ground (z) -(ft)40.0 Job Number Standard Wall Height - (ft)8.0 Preparer Mean Roof Height (h) - (ft)200.0 Building Width (ft)400.0 Building Length (ft)60.0 Roof Slope (x:12)0.0 Flat - No Hill Roof Angle (degrees)0.00 (a) Edge Strip (ft) 6.00 12.00 (1)master bed 4 4 141.8 96.0 94.5 42.8 -55.1 16-0617.02 80/-80 ES Windows ES-SGD2020 (2)Living room 4 4 141.8 96.0 94.5 42.8 -55.1 16-0617.02 80/-80 ES Windows ES-SGD2020 (3)Guest bedroom 4 4 141.8 96.0 94.5 42.8 -55.1 16-0617.02 80-/80 ES Windows ES-SGD2020 Model Number WIND LOAD DESIGN INFORMATION WALL OPENING INFORMATIONWALL OPENING INFORMATIONMax Pressure Per NOA APPLYING WIND LOAD FOR: EFFECTIVE WIND AREA (sqft) BUILDING INFORMATION Wind Velocity (mph) Building Category Nominal Wind Velocity (mph) Design Wind Speed Exposure End Zone (ft) ZONE z, (ft) ManufacturerWIDTH (inches) OPENING ELEVATION (feet) Nominal Wind Load Pressures x, (ft) MAXIMUM NEGATIVE PRESSURE (psf) MAXIMUM POSITIVE PRESSURE (psf) LENGTH (inches) NOA Approval Number Parapet Along Roof Perimeter (ft) JOB INFORMATION ASCE 7-10 Pahl Construction Pedro MendigurenClient Address 5047 North State Rd A1A #1802 hutchinson Wall Openings (Windows & Doors) Wind Load Program TOPOGRAPHIC FACTOR Hill Shape H, (ft) Lh, (ft) 2001 - 2017 © Courtney www.windloadcalc.com 11/2/2020 Page1 WINDLOADCALC.com Nominal 170 131.7 II Hurricane D Internal Pressure Enclosed Company Height above ground (z) -(ft)40.0 Job Number Standard Wall Height - (ft)8.0 Preparer Mean Roof Height (h) - (ft)200.0 Building Width (ft)400.0 Building Length (ft)60.0 Roof Slope (x:12)0.0 Flat - No Hill Roof Angle (degrees)0.00 (a) Edge Strip (ft) 6.00 12.00 Model Number WIND LOAD DESIGN INFORMATION WALL OPENING INFORMATIONMax Pressure Per NOA APPLYING WIND LOAD FOR: EFFECTIVE WIND AREA (sqft) BUILDING INFORMATION Wind Velocity (mph) Building Category Nominal Wind Velocity (mph) Design Wind Speed Exposure End Zone (ft) ZONE z, (ft) ManufacturerWIDTH (inches) OPENING ELEVATION (feet) Nominal Wind Load Pressures x, (ft) MAXIMUM NEGATIVE PRESSURE (psf) MAXIMUM POSITIVE PRESSURE (psf) LENGTH (inches) NOA Approval Number Parapet Along Roof Perimeter (ft) JOB INFORMATION ASCE 7-10 Pahl Construction Pedro MendigurenClient Address 5047 North State Rd A1A #1802 hutchinson Wall Openings (Windows & Doors) Wind Load Program TOPOGRAPHIC FACTOR Hill Shape H, (ft) Lh, (ft) 2001 - 2017 © Courtney WALL OPENING INFORMATIONwww.windloadcalc.com 11/2/2020 Page2