HomeMy WebLinkAboutEnergy CodeFOMM' 60OA-2004R EnergyGauge® 4.5
y
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
Residential Whole Building Performance Method A
Project Name: ST. JOHNS EXTERIOR Builder:
Address: 5a l FS Permitting Office:
City, State: , � Q t pR 3q4 sl Permit Number:
Owner: Jurisdiction Number:
Climate Zone: Central
1. New construction or existing
New
2. Single family or multi -family
_
Single family
3. Number of units, if multi -family
I _
4. Number of Bedrooms
3 _
5. Is this a worst case?
Yes
6. Conditioned floor area (ft2)
_
1958 ft2
7. Glass type and area: (Label reqd. by 137104.4.5
_
if not default)
a. U-factor: Description Area
(or Single or Double DEFAULT) 7a(Sngle Default) 141.0 ft' _
b. SHGC:
(or Clear or Tint DEFAULT) 7b.
(Clear) 161.0 ft2 _
8. Floor types
a. Slab -On -Grade Edge Insulation
R=0.0, 153.0(p) ft _
b. Raised Wood, Adjacent
R=11.0, 217.0ft2 _
c. N/A
9. Wall types
a. Frame, Wood, Exterior
R=11.0, 1459.0 ft2 _
b. Concrete, Ext Insul, Exterior
R=4.1, 557.0 ft2 _
c. Frame, Wood, Adjacent
R=11.0, 270.0 ft2 _
d. N/A
e. N/A
_
10. Ceiling types
_
_
a. Under Attic
R=19.0, 1382.0 112
b. N/A
c. N/A
_
11. Ducts
a. Sup: Unc. Ret: Con. AH(Sealed):Interior
Sup. R=6.0, 175.0 ft
b. N/A
12. Cooling systems
a. Central Unit Cap: 42.5 kBtu/hr
SEER:13.00 _
b. N/A
c. N/A
COPY-
13. Heating systems O U/y� _©C>'7 0
a. Electric Heat Pump - / Cap: 42.5 kBtu/hr
HSPF:7.90 _
b. N/A
c. N/A
14. Hot water systems
a. Electric Resistance
b. N/A
c. Conservation credits
(HR-Heat recovery, Solar
DHP-Dedicated heat pump)
15. HVAC credits
(CF-Ceiling fan, CV -Cross ventilation,
HF-Whole house fan,
PT -Programmable Thermostat,
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
Glass/Floor Area: 0.08 Total as -built points: 21752 PASS
Total base points: 24135
I hereby certify that the plans and specifications covered by
this calculation are in co fiance with the Florida Energy
Code.
PREPARED
DATE:
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGENT:
DATE: 9/5
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
BUILDING OFFICIAL:
DATE:
i rreoominant glass type. For actual glass type and areas, see Summer & Winter Glass output on pages 2&4.
EnergyGauge® (Version: FLRCSB v4.5)
Cap: 50.0 gallons
EF: 0.90
PT, _
SHE STgT,o�+
-01
FORM 60OA-2004R EnergyGauge® 4.5
�r SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
I ADDRESS: , , , PERMIT #:
BASE
AS -BUILT
GLASS TYPES
.18 X Conditioned X BSPM =
Points
Overhang
Floor Area
Type/SC
Ornt
Len Hgt
Area X
SPM X SOF
= Points
.18 1958.0
24.35
8582.0
1.Single, Clear
E
1.0 8.0
48.0
63.97 0.99
3041.0
2.Single, Clear
E
1.0 6.0
40.0
63.97 0.97
2479.0
3.Single, Clear
W
1.0 6.0
16.0
57.68 0.97
893.0
4.Single, Clear
W
6.0 6.0
5.0
57.68 0.54
157.0
5.Single, Clear
W
1.0 6.0
32.0
57.68 0.97
1787.0
6.Single, Clear
N
1.0 7.0
20.0
30.19 0.98
594.0
As -Built Total:
161.0
8951.0
WALL TYPES
Area X
BSPM
= Points
Type
R-Value Area
X SPM =
Points
Adjacent
270.0
0.70
189.0
1. Frame, Wood, Exterior
11.0
1459.0
1.90
2772.1
Exterior
2016.0
1.90
3830.4
2. Concrete, Ext Insul, Exterior
4.1
557.0
0.48
267.4
3. Frame, Wood, Adjacent
11.0
270.0
0.70
189.0
Base Total:
2286.0
4019.4
As -Built Total:
2286.0
3228.5
DOOR TYPES
Area X
BSPM
= Points
Type
Area
X SPM =
Points
Adjacent
18.0
1.60
28.8
1.Exterior Wood
20.0
7.20
144.0
Exterior
20.0
4.80
96.0
2.Adjacent Wood
18.0
2.40
43.2
Base Total:
38.0
124.8
As -Built Total:
38.0
187.2
CEILING TYPES
Area X
BSPM
= Points
Type
R-Value
Area X SPM X SCM =
Points
Under Attic
1382.0
2.13
2943.7
1. Under Attic
19.0
1382.0 2.82 X 1.00
3897.2
Base Total:
1382.0
2943.7
As -Built Total:
1382.0
3897.2
FLOOR TYPES
Area X BSPM
= Points
Type
R-Value Area
X SPM =
Points
Slab 153.0(p)
-31.8
-4865.4
1. Slab -On -Grade Edge Insulation
0.0
153.0(p
-31.90
-4880.7
Raised
217.0
-3.43
-744.3
2. Raised Wood, Adjacent
11.0
217.0
1.80
390.6
Base Total:
-5609.7
As -Built Total:
370.0
-4490.1
INFILTRATION
Area X BSPM
= Points
Area X SPM =
Points
1958.0
14.31
28019.0
1958.0
14.31
28019.0
EnergyGauge® DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5
^ FORM 600A-2004R EnergyGauge® 4.5
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS:... PERMIT #:
BASE
AS -BUILT
Summer Base Points: 38079.1
Summer As -Built Points:
39792.8
Total Summer X System = Cooling
Total X Cap
X Duct X System X
Credit =
Cooling
Points Multiplier Points
Component Ratio
Multiplier Multiplier
Multiplier
Points
(System - Points)
(DM x DSM x AHU)
(sys 1: Central Unit 42500btuh ,SEER/EFF(13.0) Ducts:Unc(S),Con(R),Int(AH),R6.0(INS)
39793 1.00
(1.08 x 1.150 x 0.85) 0.260
0.950
10427.7
38079.1 0.3250 12375.7
39792.8 1.00
1.061 0.260
0.950
10427.7
EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5
.I ^ FORM 60OA-2004R EnergyGauge® 4.5
w -
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
I ADDRESS: , , , PERMIT #:
BASE
AS -BUILT
GLASS TYPES
.18 X Conditioned X BWPM =
Points
Overhang
Floor Area
Type/SC
11.Single,
Ornt
Len Hgt
Area X WPM X
WOF = Point
.18 1958.0
9.11
3211.0
Clear
E
1.0 8.0
48.0 12.37
1.01
596.0
2.Single, Clear
E
1.0 6.0
40.0 12.37
1.01
499.0
3.Single, Clear
W
1.0 6.0
16.0 13.25
1.00
212.0
4.Single, Clear
W
6.0 6.0
5.0 13.25
1.08
71.0
5.Single, Clear
W
1.0 6.0
32.0 13.25
1.00
425.0
6.Single, Clear
N
1.0 7.0
20.0 15.07
1.00
300.0
As -Built Total:
161.0
2103.0
WALL TYPES
Area X
BWPM
= Points
Type
R-Value
Area X WPM
=
Points
Adjacent
270.0
1.80
486.0
1. Frame, Wood, Exterior
11.0
1459.0 2.00
2918.0
Exterior
2016.0
2.00
4032.0
2. Concrete, Ext Insul, Exterior
4.1
557.0 2.36
1314.5
3. Frame, Wood, Adjacent
11.0
270.0 1.80
486.0
Base Total:
2286.0
4518.0
As -Built Total:
2286.0
4718.5
DOOR TYPES
Area X
BWPM
= Points
Type
Area X WPM
=
Points
Adjacent
18.0
4.00
72.0
1.Exterior Wood
20.0 7.60
152.0
Exterior
20.0
5.10
102.0
2.Adjacent Wood
18.0 5.90
106.2
Base Total:
38.0
174.0
As -Built Total:
38.0
258.2
CEILING TYPES Area X
BWPM
= Points
Type
R-Value Area X WPM X WCM =
Points
Under Attic
1382.0
0.64
884.5
1. Under Attic
19.0
1382.0 0.87 X 1.00
1202.3
Base Total:
1382.0
884.5
As -Built Total:
1382.0
1202.3
FLOOR TYPES
Area X
BWPM
= Points
Type
R-Value
Area X WPM
=
Points
Slab
153.0(p)
-1.9
-290.7
1. Slab -On -Grade Edge Insulation
0.0 153.0(p 2.50
382.5
Raised
217.0
-0.20
-43.4
2. Raised Wood, Adjacent
11.0
217.0 1.80
390.6
Base Total:
.334.1
As -Built Total:
370.0
773.1
INFILTRATION
Area X
BWPM
= Points
Area X WPM
=
Points
1958.0
-0.28
-548.2
1958.0 -0.28
-548.2
EnergyGauge® DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5
FORM 60OA-2004R EnergyGauge® 4.5
WATER HEATING & CODE COMPLIANCE STATUS
Residential Whole Building Performance Method A - Details
I ADDRESS: , , , PERMIT #: I
BASE AS -BUILT
WATER HEATING
Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total
Bedrooms Volume Bedrooms Ratio Multiplier
3 2460.00 7380.0 50.0 0.90 3 1.00 2514.67 1.00 7544.0
As -Built Total: 75".0
CODE
COMPLIANCE
STATUS
BASE
AS -BUILT
Cooling + Heating +
Points Points
Hot Water
Points
= Total
Points
Cooling
Points
+ Heating + Hot Water = Total
Points Points Points
12376 4379
7380
24135
10428
3780 7544 21752
PASS
y0_,t11E STAp�O�
W
� a
EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5
J FORM 60OA-2004R EnergyGauge® 4.5
Code Compliance Checklist
Residential Whole Building Performance Method A - Details
I ADDRESS: , , , PERMIT #:
6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST
COMPONENTS
SECTION
REQUIREMENTS FOR EACH PRACTICE
CHECK
Exterior Windows & Doors
606.1.ABC.1.1
Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area.
Exterior & Adjacent Walls
606.1.ABC.1.2.1
Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall;
foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility
penetrations; between wall panels & top/bottom plates; between walls and floor.
EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends
from, and is sealed to, the foundation to the top plate.
Floors
606.1.ABC.1.2.2
Penetrations/openings >1/8" sealed unless backed by truss or joint members.
EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed
to the perimeter, penetrations and seams.
Ceilings
606.1.ABC.1.2.3
Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases,
soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate;
attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is
installed that is sealed at the perimeter, at penetrations and seams.
Recessed Lighting Fixtures
606.1.ABC.1.2.4
Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a
sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from
conditioned space, tested.
Multi -story Houses
606.1.ABC.1.2.5
Air barrier on erimeter of floor cavity between floors.
Additional Infiltration reqts
606.1.ABC.1.3
Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA,
have combustion air.
6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.)
COMPONENTS
SECTION
REQUIREMENTS
CHECK
Water Heaters
612.1
Comply with efficiency requirements in Table 612.1.ABC.3.2. Switch or clearly marked cir
breaker electric or cutoff as must be provided. External or built-in heat trap required.
Swimming Pools & Spas
612.1
Spas & heated pools must have covers (except solar heated). Non-commercial pools
must have a pump timer. Gas spa & pool heaters must have a minimum thermal
efficiency of 78%.
Shower heads
612.1
Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG.
Air Distribution Systems
610.1
All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically
attached, sealed, insulated, and installed in accordance with the criteria of Section 610.
Ducts in unconditioned attics: R-6 min. insulation.
HVAC Controls
607.1
Se crate readil accessible manual or automatic thermostat for each system.
Insulation
604.1, 602.1
Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides.
Common ceiling & floors R-11.
EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE SCORE* = 87.6
The higher the score, the more efficient the home.
I. New construction or existing
New
2. Single family or multi -family
Single family
3. Number of units, if multi -family
1
4. Number of Bedrooms
3
5. Is this a worst case?
Yes
6. Conditioned floor area (ft2)
1958 ft2
7. Glass type and area: (Label reqd.
by 13-104.4.5 if not default)
a. U-factor:
Description Area
(or Single or Double DEFAULT) 7a(Sngle Default) 141.0 ft'
b. SHGC:
(or Clear or Tint DEFAULT)
7b. (Clear) 161.0 ftz
8. Floor types
a. Slab -On -Grade Edge Insulation
R=0.0, 153.0(p) ft
b. Raised Wood, Adjacent
R=11.0, 217.0ft2
c. N/A
9. Wall types
a. Frame, Wood, Exterior
R=11.0, 1459.0 ft'
b. Concrete, Ext Insul, Exterior
R=4.1, 557.0 ft2
c. Frame, Wood, Adjacent
R=11.0, 270.0 ft2
d. N/A
e. N/A
10. Ceiling types
a. Under Attic
R=19.0, 1382.0 ft2
b. N/A
c. N/A
11. Ducts
a. Sup: Unc. Ret: Con. AH(Sealed):Interior
Sup. R=6.0, 175.0 ft
b. N/A
12. Cooling systems
a. Central Unit Cap: 42.5 kBtu/hr
_ SEER:13.00 _
b. N/A
c. N/A
13. Heating systems
a. Electric Heat Pump Cap: 42.5 kBtu/hr
HSPF:7.90 _
b. N/A
c. N/A
14. Hot water systems
a. Electric Resistance Cap: 50.0 gallons _
_ EF: 0.90 _
b. N/A
_ c. Conservation credits _
(HR-Heat recovery, Solar
DHP-Dedicated heat pump)
15. HVAC credits PT, _
(CF-Ceiling fan, CV -Cross ventilation,
HF-Whole house fan,
PT -Programmable Thermostat,
MZ-C-Multizone.cooling,
MZ-H-Multizone heating)
I certify that this home has complied with the Florida Energy Efficiency Code For Building
Construction through the above energy saving features which will be installed (or exceeded) y0�THE sTgT�o
in this home before final in tion. Otherwise, a ne EPL Display Card will be completed
based on installed Code co. iant fea a 0
Builder Signature: Date: 51877a
Address of New Home: 5 Los ��ntie nsJaty/FLZip: F.0 OD
*NOTE: The home's estimated energy performance score is only available through the FLARES computer program.
This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPADOE EnergyStarrmdesignation),
your home may qualify for energy efficiency mortgage (EEM) incentives if you obtain a Florida Energy Gauge Rating.
Contact the Energy Gauge Hotline at 3211638-1492 or see the Energy Gauge web site at www.fsec. ucf edu for
information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building
Construction, contact the Department of Community Affairs at 8501487-1824.
l Predominant glass type. For actual glass type and areas see Summer & Winter Glass output on ages 2&4.
KnergyGauge® (Version: FLRCSt3 v4.5)
w rig tsoft-
Project Summary
Entire House
Proiect� In
For: ST. JOHN'S EXTERIOR
Notes:'
Job:
Date: Mar 24, 2007
By: G.CARMACK
Desi hnforrriat[(' n
Weather:
Winter Design Conditions
Outside db
42
OF
Inside db
70
OF
Design TD
28
OF
Heating Summary
Structure
23.717
Btuh
Ducts
2372
Btuh
Central vent (100 cfm)
3077
Btuh
Humidification
0
Btuh
Piping
0
Btuh
Equipment load
29166
Btuh
Infiltration
Fort Pierce, FL, US
Method Simplified
Construction quality Average
Fireplaces 0
Area (ft2}
Heatin�gg
1958
Coolingg
1958
Volume (fv)
17048
17048
Air changes/hour
0.38
0.20
Equiv. AVF (cfm)
108
57
Heating Equipment Summary
Make TEMPSTAR
Trade HEAT PUMP
Model N2H342AKD
Efficiency
Heating input
Heating output
Temperature rise
Actual air flow
Air flow factor
Static pressure
Space thermostat
7.9 HSPF
0 Btuh @ 47°F
0 OF
1353 cfm
0.052 cfm/Btuh
0.60 in H2O
Summer Design Conditions
Outside db
90
OF
Inside db
75
OF
Design TD
15
OF
Daily rangge
Relative fiumidity
L
50
%
Moisture difference
61
gr/lb
Sensible Cooling Equipment Load Sizing
Structure
25342
Btuh
Ducts
2534
Btuh
Central vent (100 cfm)
1649
Btuh
Blower
0
Btuh
Use manufacturer's data
n
Rate/swing multiplier
Equipmenf load
0.95
28049
Btuh
sensible
Latent Cooling Equipment
Load Sizing
Structure
3574
Btuh
Ducts
2552
Btuh
Central vent (100 cfm)
4177
Btuh
Equipment latent load
10303
Btuh
Equipment total load
38352
Btuh
Req. total capacity at 0.77 SHR
3.0
ton
Cooling Equipment
Summary
Make TEMPSTAR
Trade HEAT PUMP
Cond N2H342AKD
Coil FEM2X4200
Efficiency
13 SEER
Sensible cooling
32725
Btuh
Latent cooling
9775
Btuh
Total cooling
42500
Btuh
Actual air flow
1353
cfm
Air flow factor
0.049
cfm/Btuh
Static pressure
0.60
in H2O
Load sensible heat ratio
0.74
Bolddtalic values have been manually overridden
Printout certified by ACCA to meet all requirements of Manual J 8th Ed.
wrlightsoft Right -Suite Residential 6.0.90 RSR21115 2007-Sep-0513:15:01
,4001 C:\Documents and Settings\gcarmack\My DocumentsNan J. Calcs 2007\FT.PIERCE\ST. JOHN'S EXTERIOR.rrp Page 1
wri htso -
o°pltuto
Building Analysis
Entire House
• • •
For: ST. JOHN'S EXTERIOR
Job:
Date: Mar 24, 2007
By: G.CARMACK
D- •
• • •ns
Location:
Indoor:
Heating
Cooling
Fort Pierce, FL, US
Indoor temperature (°F)
70
75
Elevation: 25 ft
Design TD (°F)
28
15
Latitude: 27°N
Relative humidity (%)
30
50
Outdoor: Heating
Cooling
Moisture difference (gr/lb)
1.1
61.5
Dry bulb (OF).42
90
Infiltration:
Daily range ( F) -
Wet bulb (°F� -
Wind speed mph) 15.0
15 (L)
78
7.5
Method
Construction quality
Simplified
Average
Fireplaces
0
He"atirig.'
Component
Btuh/ft2
Btuh
% of load
Walls
2.9
6645
22.8
Glazing
35.6
5014
17.2
Doors
10.9
415
1.4
Ceilings
1.4
2188
7.5
Floors
4.5
6132
21.0
Infiltration
1.3
3322
11.4
Ducts
2372
8.1
Piping
0
0.0
Humidification
0
0.0
Ventilation
3077
10.6
Adjustments
0
Total
29166
100.0
Coolirig,6
Component
Btuh/ftz
Btuh
% of load
Walls
2.5
5700
19.3
Glazing
89.5
12624
42.8
Doors
11.3
430
1.5
Ceilings
2.6
4103
13.9
Floors
0.1
168
0.6
Infiltration
0.4
937
3.2
Ducts
2534
8.6
Ventilation
1649
5.6
Internal gains
1380
4.7
Blower
0
0.0
Adjustments
0
Total
29525
100.0
Overall U-value = 0.135 Btuh/ft2-°F
WARNING: suspicious slab -on -grade floor perimeter in BDR #3.
w11710htsoft Right -Suite Residential 6.0.90 RSR21115 2007-Sep 05 13:15:01
ACCA C:\Documents and Settings\gcarmack\My Documents\Man J Calcs 2007\FT.PIERCE\ST. JOHN'S EXTERIOR.rrp Page 1