HomeMy WebLinkAbout2020-11-16_Best-Western_Drawings_Rev.0-(Stamped).KH Comments FJ Submittal #03 0130-6.0 struc 03 0130 - CONCRETE REHABILITATION Structural Preservation Systems,LLC Project:428374- Best Western at Port St Lucie Walkway 2001 Blount Road 7900 S US Hwy 1 Pompano Beach,Florida 33069 Port St. Lucie, Florida 34952 Phone:954-984-9555 Fax:954-984-9559 Submittal #7 - Shoring Design REVISION: 0 SUBMITTAL MANAGER: Jean-Simon Berube (STRUCTURAL- Florida) STATUS: Open DATE CREATED: 11/17/2020 ISSUE DATE: 11/17/2020 SPEC SECTION: 03 0130-CONCRETE REHABILITATION RESPONSIBLE STRUCTURAL-Florida RECEIVED FROM: Jean-Simon Berube CONTRACTOR: RECEIVED DATE: 11/17/2020 SUBMIT BY: 11/17/2020 FINAL DUE DATE: 11/18/2020 LOCATION: COST CODE: TYPE: Shop Drawing APPROVERS: Leetal Dana(Kimley Horn),Noel Ramirez(Kimley Horn) BALL IN COURT: Leetal Dana(Kimley Horn), Noel Ramirez(Kimley Horn) DISTRIBUTION: DESCRIPTION: Signed and sealed shoring design for concrete repairs. SUBMITTAL WORKFLOW NAME SENT DATE DUE DATE RETURNED RESPONSE ATTACHMENTS COMMENTS DATE General 2020-11-16 Best Information Western_Drawings Rev.0 Attachments (Stamped).pdf Leetal Dana 11/17/2020 11/18/2020 Pending Noel Ramirez 11/17/2020 11/18/2020 Pending ® No Exceptions Taken ❑ Revise and Resubmit ❑ Exceptions Noted ❑ Rejected Approval is only for conformance with the design con- cept of the project and general compliance with the information given in our Plans and Specifications. Contractor is responsible for dimensions to be confirmed and correlated at the job site; for information that pertains to the fabrication processes or to techniques of construction; and for conformance to the requirements of the plans and specifications. KIMLEY-HORN AND ASSOCIATES, INC. Date 11/17/2020 By Noel Ramirez _ BY DATE COPIES TO Structural Preservation Systems, LLC Page 1 of 1 Printed On: 11/18/2020 12:05 PM GENERAL NOTES: P° 1. STRUCTURAL TECHNOLOGIES' SCOPE OF WORK IS LIMITED TO THE DEVELOPMENT OF SHORING LAYOUT FOR THE PARTIAL DEPTH REPAIRS OF THE SLAB AREAS ON LEVEL 2 AT THE BEST WESTERN HOTEL (NORTH AND SOUTH BUILDINGS), IN PORT ST. LUCIE, FL. 2 cn 2. THE SLAB AREAS TO BE REPAIRED WERE PROVIDED IN DRAWING SHEETS S-101 AND S-102 (DATED 8/19/2020) BY KIMLEY-HORN &ASSOCIATES, IN CORAL GABLES, FL,THE ENGINEER OF RECORD FOR THIS PROJECT. 3. NO WARRANTY EXPRESSED OR IMPLIED TO THE ADEQUACY AND CODE COMPLIANCE OF THE EXISTING STRUCTURE IS MADE BY VIRTUE OF THIS SUBMITTAL. THIS DESIGN IS NOT TO BE USED UNLESS APPROVED F a BY THE ENGINEER OF RECORD, AND STRUCTURAL TECHNOLOGIES STRONGPOINT DISCLAIMS ANY LIABILITY a FOR DESIGN OR DETAILS OF OTHERS. c z N N N o z SHORING NOTES: 0 1. SHORING DESIGN IS BASED ON THE FOLLOWING LOADS: (] N W � a A. SLAB (4 IN. THICK) SELFWEIGHT a B. 50 PSF CONSTRUCTION LOAD z m z w w 2. SHORING DESIGN IS BASED ON THE ALLOWABLE LOAD CAPACITY FOR SHORING POSTS OF 5,000 LBS a a E. (MINIMUM). NOTIFY STRUCTURAL TECHNOLOGIES IF SHORING POSTS OF A LOWER CAPACITY ARE USED. 8 3. SHORING POSTS IN THE VICINITY OF REPAIR AREAS SHALL BE INSTALLED PRIOR TO COMMENCEMENT OF o ANY REPAIR WORK. MAINTAIN SHORING POSTS IN PLACE UNTIL CONCRETE REPAIR MATERIAL HAS CURED. /� �`v W C a o 4. REFER TO DRAWING SHEET S2 AND S3 FOR LAYOUT OF SHORING POSTS AROUND REPAIR AREAS. `moo a 5. READ CAUTIONS AND LIMITATIONS OF THE SHORING EQUIPMENT AND FOLLOW MANUFACTURER'S C.7°z o INSTRUCTIONS DURING ERECTION, CONSTRUCTION, AND DISMANTLING IN ACCORDANCE WITH OSHA'S �u a o SAFETY REGULATIONS. y F o U � 0 5 m b N_ 1 2.1 3 4.1 5 6.1 1 2.1 3 4.1 TP16-6" 6.16 19'-3" 30'-0" 30'-6" 30'-0" 19'-3" 15'-6" 15'-6" 19'-3" 30'-0" 30--6" 30'-0" 19'-3" 5'-6" m o >,, .. 5_y„ 6._5" 6�5�� 6�_4" 6�6" 5-5 6�_4-- 5�_5. 6._5" 5'_4" 6�_6" y E. _y L�m a cc �5s m e o U p_- N`o I I I I I I I I I I I I I I I I I I I I I comae _ ti - 291 Lu L o§~E a Q L E '61 I S TO � EN i AREA BE I � �P.• �\G SF' •,•-9 � I C� s I I I Wj REPAIRED(TYP.) No 80094 �3 A. q STATE OF z i �`S'•.F<ORIDP'.•'•G\�� � a a cam/] F6 c� z z FLORIDA LICENSE NO.80094 x q (EXPIRES 02/28/2021) cn STRUCTURAL TECHNOLOGIES STRONGPOINT,LLC. W / C.O.A.NO.29228 Lq W o C7 THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND o SEALED BY SILVIA V.ROCCA CAMASCA,PE.ON LEVEL 2 NORTH BUILDING REPAIR PLAN ` ��LEVEL 2 SOUTH BUILDING REPAIR PLAN ` COPIES O USING A DIGITAL SIGNATURE. PRINTED S1 PER DRAWING SHEET S-102(DATED 8/19/2020)BY COPIES OF THIS DOCUMENT ARE NOT CONSIDERED JOB N0: 428374 S1 PER DRAWING SHEET S-101(DATED 8/19/2020)BY PROJECT FOR PER AND SEALED,AND THE SIGNATURE MUST BE PROJECT FOR VERIFIED ON ANY ELECTRONIC COPIES. SHEET: S1 w FREE END 5 KIP(MIN.)POST 5'-0"(MAX)FREE END SHORE(TYP.) FREE END REPAIR AREA r VARIES - REPAIR AREA - - - REPAIR AREA - c c a U2 U2 c z L 2'-0"(MAX) L 2'-0"(MAX) o 0 0 N N N O BUILDING BUILDING BUILDING VA VA VA ., a NOTE: NOTE: NOTE: " s FOR REPAIRS AT FREE END OF CANTILEVER SLAB,PROVIDE SHORING IF LENGTH OF REPAIR"L"LESS OR EQUAL THAN 5 FT USE ONE IF LENGTH OF REPAIR"L"EXCEEDS 5 FT,PROVIDE POST SHORES AT 5 FT O.C.(MAX.) z AS REQUIRED TO SUPPORT REPAIR ZONE. POST SHORE. ALONG THE FREE EDGE OF THE SLAB AND ONE POST ON EACH SIDE OF REPAIR AREA. 1 CASE 1: REPAIR AREA AT FREE END 2A CASE 2A: REPAIR AREA AT MIDSPAN 2B CASE 2B: REPAIR AREA AT MIDSPAN $ S2 S2 L<_5'-0" 52 L>5'-0" `a W c a o O 5'-0"(MAX) `= a FREE END FREE END V O Z a 2 u pm� Ty W F E N 0 yF L o U2 U2 0 2'-0"(MAX) L 2'-0"(MAX) o Z z S S 3 Lo o mEE -_ ma REPAIR AREA REPAIR AREA - - - 3 E_ 5 a o o f oa oa cl c- BUILDING BUILDING - - - VA VA 7.5F� 6�- 8 Eoa`�.--E \ / - =T- OCCq a- 2 1E ��_� NOTE: CASE 3B: \\ � C / ��E`�'�s„� IF LENGTH OF REPAIR"L"IS LESS OR EQUAL THAN S-0",USE IF LENGTH OF REPAIR"L"GREATER THAN 5'-0",PROVIDE POST SHORES AT 5 FT O.C.(MAX.) i ONE POST SHORE AT FREE EDGE OF SLAB. ALONG THE FREE EDGE OF THE SLAB,AND ONE POST ON EACH SIDE OF THE REPAIR �Q�••''\,\CENSF C, AREA. J •' L2 co No 80094 — v2 3A CASE 3A: REPAIR AREA CLOSE TO BUILDING sB CASE 3B: REPAIR AREA CLOSE TO BUILDING S2 L<5'-0" S2 L>5'-0" a �Q STATE OF �(/�� p� a Z F4 O RIO P' E e. Pp-4 I cn /ONAL G\vG /01111110 U w FLORIDA LICENSE NO.80094 0 a (EXPIRES02/28/2021) Z STRUCTURAL TECHNOLOGIES STRONGPOINT,L-C. py C.O.A.NO.29228 � Fn THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND o SEALED BY SILVIA V.ROCCA CAMASCA,PE.ON m 11/17/2020 USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED JOB NO: 428374 SIGNED AND SEALED,AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. SHEET: S2 w VARIES 10'-5,'(VIF) o 2'-0"(MAX) 5'-0"(MAX) 2'-0"(MAX) FREE END cli r N REPAIR AREA O z i 0 N N O \D \O 'Z REPAIR AREA 0 0 z z c ---------------- m REPAIR AREA m o BUILDING NOTE: q coFOR REPAIRS EXTENDING OVER THE FULL LENGTH OF THE SLAB,PROVIDE POST SHORES AT 5 FT O.C.(MAX.) m o C7 `ca W c a o 1 CASE 4: REPAIR AREA OVER FULL SLAB LENGTH L GS3 `=O `a J S/2 S/2 F.2 a o u 4-0 W f y� a o 5• U 3 O O m P u�i NOTES: IF LENGTH OF REPAIR"L"IS LESS THAN 3'-0",PROVIDE SHORING TO SUPPORT REPAIR ZONE. s IF LENGTH OF REPAIR"L"EXCEEDS 3'-0",PROVIDE POST SHORES AT 3-0"O.C.(MAX.) °EE �2 CASE 5: REPAIR AREA AT INTERIOR SLAB 3 LL a mFcoJ� afnE S3 EE rn o U p_ mEc-'aO - -E v m m a - - - s E El \,\GENS,�- J . cf' CQ c No 80094 d -10 z Q� STATE OF Z i F�ORIDP.•' ��� E e. o w a s!0NAU 0 W w a FLORIDA LICENSE NO.80094 0 a (EXPIRES02/28/2021) Z STRUCTURAL TECHNOLOGIES STRONGPOINT,LLC. py C.O.A.NO.29228 � Fn THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND o SEALED BY SILVIA V.ROCCA CAMASCA,PE.ON m 11/17/2020 USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED JOB NO: 428374 SIGNED AND SEALED,AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. SHEET: S3