HomeMy WebLinkAboutDESIGN PRESSURE CALCULATIONSProperty Information
Owner:Sandra Elizabeth Knepp
Address:3266 Lakeshore DR
Fort Pierce, FL 34949
Building Information
Wind Zone:170 MPH.
Exposure Category:B
Minimum Building Dimension:22 ft.
Mean Roof Height:15 ft.
Risk Category:II
Design Pressure Calculations
Opening
Number
Location
Zone
Device
Width (in)
Device
Height (in)
Device
Elevation (ft)
Max Positive
Pressure (psf)
Max Negative
Pressure (psf)
1 Int 7 0.0 0.0
2 Int 31 45.5 7 31.2 -33.8
3 Int 57 56 7 29.6 -32.2
4 Int 70 56 7 29.1 -31.8
5 Int 70 56 7 29.1 -31.8
Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. 6th Edition (2017) Florida Building Code.
Page 1 of 1