HomeMy WebLinkAboutDESIGN PRESSURE CALCULATIONSProperty Information Owner:Sandra Elizabeth Knepp Address:3266 Lakeshore DR Fort Pierce, FL 34949 Building Information Wind Zone:170 MPH. Exposure Category:B Minimum Building Dimension:22 ft. Mean Roof Height:15 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 Int 7 0.0 0.0 2 Int 31 45.5 7 31.2 -33.8 3 Int 57 56 7 29.6 -32.2 4 Int 70 56 7 29.1 -31.8 5 Int 70 56 7 29.1 -31.8 Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. 6th Edition (2017) Florida Building Code. Page 1 of 1