HomeMy WebLinkAboutEnergy CodeI r 1f - f
• FORM 60OA-2004R EnergyGauge® 4.5
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
Residential Whole Building Performance Method A
Project Name: ST. JOHNS INTERIOR UNIT Builder:
Address: S 2k i CP nl\ qm c;.-., 0 S Permitting Office:
City, State: rz_�__ Pj p �_- L. 3t{ci Sk Permit Number:
Owner: ELECTRIC Jurisdiction Number:
Climate Zone: Central
] . New construction or existing
New _
12. Cooling systems
2. Single family or multi -family
Single family _
a. Central Unit
Cap: 42.5 kBtu/hr
3. Number of units, if multi -family
1 _
SEER: 13.00
4. Number of Bedrooms
3 _
b. N/A
_
5. Is this a worst case?
ye _
_
6. Conditioned floor area (ftz)
1912 ftz
c. N/A
7. Glass type and area: (Label reqd.
_
by 13-104.4.5 if not default)
_
a. U-factor:
Description Area
13. Heating systems
_
(or Single or Double DEFAULT) 7a(Sngle Default) 141.0 ftz _
a. Electric Heat Pump
Cap: 42.5 kBtu/hr
b. SHGC:
HSPF:7.90
(or Clear or Tint DEFAULT)
7b. (Clear) 141.0 ftz _
b. N/A
_
_
8. Floor types
a. Slab -On -Grade Edge Insulation
R=0.0, 153.0(p) ft _
c. N/A
b. Raised Wood, Adjacent
R=19.0, 217.0ftz
_
c. N/A
_
14. Hot water systems
9. Wall types
a. Electric Resistance
Cap: 50.0 gallons _
a. Frame, Wood, Exterior
R=11.0, 1702.0 ftz _
EF: 0.90
b. Concrete, Ext Insul, Exterior
R=4.1, 314.0 ftz _
b. N/A
_
C. Frame, Wood, Adjacent
R=11.0, 270.0 ftz
_
d. N/A
_
c. Conservation credits
e. N/A
_
(HR-Heat recovery, Solar
_
10. Ceiling types
_
DHP-Dedicated heat pump)
a. Under Attic
R=19.0, 13 00. 0 ftz
15. HVAC credits
PT,
b. N/A
_
(CF-Ceiling fan, CV -Cross ventilation,
c. N/A
_
HF-Whole house fan,
11. Ducts
_
PT -Programmable Thermostat,
a. Sup: Unc. Ret: Con. AH(Sealed):Interior
Sup. R=6.0, 175.0 ft
MZ-C-Multizone cooling,
b. N/A
_
MZ-H-Multizone heating)
Glass/Floor Area: 0.07 Total as -built points: 21133 PASS
Total base points: 23735
I hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Code.
PREPARED wz
DATE:
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGENT: w•
DATE: 9 - S- -7 ,
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
BUILDING OFFICIAL:
DATE:
i Hreaominant glass type. For actual glass type and areas, see Summer & Winter Glass output on pages 2&4.
EnergyGauge® (Version: FLRCSB v4.5)
o
WE
FORM 600A-2004R EnergyGauge® 4.5
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
I ADDRESS: , , , PERMIT #:
BASE
AS -BUILT
GLASS TYPES
.18 X Conditioned X BSPM =
Points
Overhang
Floor Area
Type/SC
Ornt Len Hgt
Area X
SPM X SOF
= Points
.18 1912.0
24.35
8380.0
1.Single, Clear
E 1.0 8.0
48.0
63.97 0.99
3041.0
2.Single, Clear
E 1.0 6.0
40.0
63.97 0.97
2479.0
3.Single, Clear
W 1.0 6.0
16.0
57.68 0.97
893.0
4.Single, Clear
W 6.0 6.0
5.0
57.68 0.54
157.0
5.Single, Clear
W 1.0 6.0
32.0
57.68 0.97
1787.0
As -Built Total:
141.0
8357.0
WALL TYPES
Area X
BSPM
= Points
Type
R-Value Area
X SPM =
Points
Adjacent
270.0
0.70
189.0
1. Frame, Wood, Exterior
11.0
1702.0
1.90
3233.8
Exterior
2016.0
1.90
3830.4
2. Concrete, Ext Insul, Exterior 4.1
314.0
0.48
150.7
3. Frame, Wood, Adjacent
11.0
270.0
0.70
189.0
Base Total:
2286.0
4019.4
As -Built Total:
2286.0
3573.5
DOOR TYPES
Area X BSPM
= Points
Type
Area
X SPM =
Points
Adjacent
18.0
1.60
28.8
1.Exterior Wood
20.0
7.20
144.0
Exterior
20.0
4.80
96.0
2.Adjacent Wood
18.0
2.40
43.2
Base Total:
38.0
124.8
As -Built Total:
38.0
187.2
CEILING TYPES
Area X
BSPM = Points
Type
R-Value
Area X SPM X SCM =
Points
Under Attic
1300.0
2.13
2769.0
1. Under Attic
19.0
1300.0 2.82 X 1.00
3666.0
Base Total:
1300.0
2769.0
As -Built Total:
1300.0
3666.0
FLOOR TYPES
Area X
BSPM
= Points
Type
R-Value Area
X SPM =
Points
Slab 153.0(p)
-31.8
-4865.4
1. Slab -On -Grade Edge Insulation 0.0
153.0(p
-31.90
-4880.7
Raised
217.0
-3.43
-744.3
2. Raised Wood, Adjacent
19.0
217.0
1.00
217.0
Base Total:
-5609.7
As -Built Total:
370.0
-4663.7
INFILTRATION
Area X
BSPM
= Points
Area X SPM =
Points
1912.0
14.31
27360.7
1912.0
14.31
27360.7
EnergyGauge® DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5
►' FORM 600A-2004R EnergyGauge® 4.5
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
I ADDRESS: , . , PERMIT #: I
BASE
AS -BUILT
Summer Base Points: 37044.2
Summer As -Built Points:
38480.7
Total Summer X System = Cooling
Total X Cap
X Duct X System X
Credit =
Cooling
Points Multiplier Points
Component Ratio
Multiplier Multiplier
Multiplier
Points
(System - Points)
(DM x DSM x AHU)
ntral Unit 42500btuh ,SEER/EFF(13.0) Ducts: Unc(S),Con(R),lnt(AH),R6.0(INS)
37044.2 0.3250 12039.4
1.00
L338480.71.00
(1.08 x 1.150 x 0.85) 0.260
1.061 0.260
0.950
0.950
10083.8
10083.8
EnergyGaugeTA° DCA Form 60OA-2004R EnergyGauge®/FIaRES'2004 FLRCSB v4.5
FORM 600A-2004R EnergyGauge® 4.5
WINTER CALCULATIONS
Residential -Whole Building Performance Method A - Details
I ADDRESS: , , , PERMIT #:
BASE
AS -BUILT
GLASS TYPES
.18 X Conditioned
X BWPM =
Points
Overhang
Floor Area
Type/SC
Ornt Len Hgt
Area X WPM X WOF = Point
.18 1912.0
9.11
3135.0
1.Single, Clear
E 1.0 8.0
48.0 12.37 1.01
596.0
2.Single, Clear
E 1.0 6.0
40.0 12.37 1.01
499.0
Mingle, Clear
W 1.0 6.0
16.0 13.25 1.00
212.0
4.Single, Clear
W 6.0 6.0
5.0 13.25 1.08
71.0
5.Single, Clear
W 1.0 6.0
32.0 13.25 1.00
425.0
As -Built Total:
141.0
1803.0
WALL TYPES
Area X
BWPM
= Points
Type
R-Value
Area X WPM =
Points
Adjacent
270.0
1.80
486.0
1. Frame, Wood, Exterior
11.0
1702.0 2.00
3404.0
Exterior
2016.0
2.00
4032.0
2. Concrete, Ext Insul, Exterior 4.1
314.0 2.36
741.0
3. Frame, Wood, Adjacent
11.0
270.0 1.80
486.0
Base Total:
2286.0
4518.0
As -Built Total:
2286.0
4631.0
DOOR TYPES
Area X
BWPM
= Points
Type
Area X WPM =
Points
Adjacent
18.0
4.00
72.0
1.Exterior Wood
20.0 7.60
152.0
Exterior
20.0
5.10
102.0
2.Adjacent Wood
18.0 5.90
106.2
Base Total:
38.0
174.0
As -Built Total:
38.0
258.2
CEILING TYPES Area X
BWPM
= Points
Type
R-Value Area X WPM X WCM =
Points
Under Attic
1300.0
0.64
832.0
1. Under Attic
19.0
1300.0 0.87 X 1.00
1131.0
Base Total:
1300.0
832.0
As -Built Total:
1300.0
1131.0
FLOOR TYPES
Area X
BWPM
= Points
Type
R-Value
Area X WPM =
Points
Slab 153.0(p)
-1.9
-290.7
1. Slab -On -Grade Edge Insulation 0.0 153.0(p 2.50
382.5
Raised
217.0
-0.20
-43.4
2. Raised Wood, Adjacent
19.0
217.0 1.00
217.0
Base Total:
-334.1
As -Built Total:
370.0
599.5
INFILTRATION
Area X
BWPM
= Points
Area X WPM =
Points
1912.0
-0.28
-535.4
1912.0 -0.28
-535.4
EnergyGauge® DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5
FORM 600A-2004R $
EnergyGauge® 4.5
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , , , . PERMIT #:
BASE
AS -BUILT
Winter Base Points:
7789.5
Winter As -Built Points:
7887.4
Total Winter X System =
Heating
Total X Cap
X Duct X System X
Credit
= Heating
Points Multiplier
Points
Component Ratio
Multiplier Multiplier
Multiplier
Points
(System - Points)
(DM x DSM x AHU)
(sys 1: Electric Heat Pump 42500 btuh ,EFF(7.9) Ducts: Unc(S),Con(R),Int(AH),R6.0
7887.4 1.000
(1.068 x 1.160 x 0.87)0.432
0.950
3505.1
7789.5 0.5540
4315.4
7887.4 1.00
1.083 0.432
0.950
3505.1
EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5
y FORM 600A-2004R
EnergyGauge® 4.5
Code Compliance Checklist
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT #:
6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST
COMPONENTS
SECTION
REQUIREMENTS FOR EACH PRACTICE
CHECK
Exterior Windows & Doors
606.1.ABC.1.1
Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area.
Exterior & Adjacent Walls
606.1.ABC.1.2.1
Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall;
foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility
penetrations; between wall panels & top/bottom plates; between walls and floor.
EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends
from, and is sealed to, the foundation to the top plate.
Floors
606.1.ABC.1.2.2
Penetrations/openings >1/8" sealed unless backed by truss or joint members.
EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed
to the perimeter, penetrations and seams.
Ceilings
606.1.ABC.1.2.3
Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases,
soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate;
attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is
installed that is sealed at the perimeter, at penetrations and seams.
Recessed Lighting Fixtures
606.1.ABC.1.2.4
Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a
sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from
conditioned space, tested.
Multi -story Houses
606.1.ABC.1.2.5
Air barrier on perimeter of floor cavity between floors.
Additional Infiltration reqts
606.1.ABC.1.3
Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA,
have combustion air.
0
6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.)
COMPONENTS
SECTION
REQUIREMENTS
CHECK
Water Heaters
612.1
Comply with efficiency requirements in Table 612.1.ABC.3.2. Switch or clearly marked cir
breaker electric or cutoff as must be provided. External or built-in heat trap required.
Swimming Pools & Spas
612.1
Spas & heated pools must have covers (except solar heated).'Non-commercial pools
must have a pump timer. Gas spa & pool heaters must have a minimum thermal
efficient of 78%.
Shower heads
612.1
Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG.
Air Distribution Systems
610.1
All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically
attached, sealed, insulated, and installed in accordance with the criteria of Section 610.
Ducts in unconditioned attics: R-6 min. insulation.
HVAC Controls
607.1
Separate readily accessible manual or automatic thermostat for each system.
Insulation
604.1, 602.1
Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides.
Common ceiling & floors R-11.
EnergyGauge TM DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5
r 1 1 4
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE SCORE* = 87.8
The higher the score, the more efficient the home.
ELECTRIC, , , ,
1. New construction or existing
New _
2. Single family or multi -family
Single family
3. Number of units, if multi -family
I
4. Number of Bedrooms
_
3 _
5. Is this a worst case?
Yes _
6. Conditioned floor area (ft2)
1912 ft2
7. Glass type and area: (Label reqd. by 13-104.4.5
_
if not default)
a. U-factor: Description Area
(or Single or Double DEFAULT) 7a(Sngle Default) 141.0 ftz
b. SHGC:
(or Clear or Tint DEFAULT) 7b.
(Clear) 141.0 ftz
8. Floor types
a. Slab -On -Grade Edge Insulation
R=0.0, 153.0(p) ft
b. Raised Wood, Adjacent
R=19.0, 217.0ft2 _
c. N/A
9. Wall types
a. Frame, Wood, Exterior
R=11.0, 1702.0 ftz _
b. Concrete, Ext Insul, Exterior
R=4.1, 314.0 ft2 _
c. Frame, Wood, Adjacent
R=11.0, 270.0 112 _
d. N/A
e. N/A
10. Ceiling types
a. Under Attic
R=19.0, 1300.0 ft2 _
b. N/A
c. N/A
_
11. Ducts
a. Sup: Unc. Ret: Con. AH(Sealed):Interior
Sup. R=6.0, 175.0 ft
b. N/A
12. Cooling systems
a. Central Unit
b. N/A
c. N/A
13. Heating systems
a. Electric Heat Pump
b. N/A
c. N/A
14. Hot water systems
a. Electric Resistance
b. N/A
c. Conservation credits
(HR-Heat recovery, Solar
DHP-Dedicated heat pump)
15. HVAC credits
(CF-Ceiling fan, CV -Cross ventilation,
HF-Whole house fan,
PT -Programmable Thermostat,
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
I certify that this home has complied with the Florida Energy Efficiency Code For Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code complia eatures.
Builder Signature: Date:
Address of New Home: S a k 1p iAct,,,C CL._,,z_�, �ECCity/FL Zip:
Cap: 42.5 kBtu/hr
SEER: 13.00
Cap: 42.5 kBtu/hr
HSPF: 7.90
Cap: 50.0 gallons _
EF: 0.90
1�
*NOTE: The home's estimated energy performance score is only available through the FLARES computer program.
This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPA/DOE EnergyStarTmdesignation),
your home may gualify for energy efficiency mortgage (EEM) incentives if you obtain a Florida Energy Gauge Rating.
Contact the Energy Gauge Hotline at 3211638-1492 or see the Energy Gauge web site at www.fsec.ucf edu for
information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building
Construction, contact the Department of CommunityAffairs at 8501487-1824.
1 Predominant glass type. For actual glass type and areas see Surnmer & Winter Glass output on ages 2&4.
hnergyGauge® (Version: FLRC9 v4.5)
PT, _