Loading...
HomeMy WebLinkAboutProject Information.� ti , Project SummaryJob: ►rilDate: Mar 24, 2007 aTertit�rara Entire House By: G.CARMACK . Proiect� Infoi�rriation For: ST. JOHN'S INTERIOR Notes: �`�, •tee l L • 3�-t S j 'Desi'qn lnformatio'n' Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range Reative humidity L 50 % Moisture difference 61 gr/lb Heating Summary Structure 23376 Btuh Ducts 2338 Btuh Central vent (100 cfm) 3077 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 28791 Btuh Infiltration Method Simplified Construction quality Fireplaces Average 0 Area Heatingg Coolingg (ft2) 1912 1912 Volume (ft3) 16598 16598 Air changes/hour 0.38 0.20 Equiv. AVF (cfm) 105 55 Heating Equipment Summary Make TEMPSTAR Trade HEAT PUMP Model N2H342AKD Efficiency 7.9 HSPF Heating input Heating output 0 Btuh @ 470F Temperature rise 0 OF Actual air flow 1353 cfm Air flow factor 0.053 cfm/Btuh Static pressure 0.60 in H2O Space thermostat Sensible Cooling Equipment Load Sizing Structure 25285 Btuh Ducts 2529 Btuh Central vent (100 cfm) 1649 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 27989 Btuh Latent Cooling Equipment Load Sizing Structure 3511 Btuh Ducts 2544 Btuh Central vent (100 cfm) 4177 Btuh Equipment latent load 10233 Btuh Equipment total load 38222 Btuh Req. total capacity at 0.77 SHR 3.0 ton Cooling Equipment Summary Make TEMPSTAR Trade HEAT PUMP Cond N2H342AKD Coil FEM2X4200 Efficiency 13 SEER Sensible cooling 32725 Btuh Latent cooling 9775 Btuh Total cooling 42500 Btuh Actual air flow 1353 cfm Air flow factor 0.049 cfm/Btuh Static pressure 0.60 in H2O Load sensible heat ratio 0.74 Boldfitalic values have been manually overridden Printout certified by ACCA to meet all requirements of Manual J 8th Ed. VVr-10 >ttso-Ft Right -Suite Residential 6.0.90RSR21115 2007-Sep-0513:15:38 ACM C:\Documents and Settings\gcarmack\My Documents\Man J Calcs 2007\FT.PIERCE\ST. JOHN'S INTERIOR.rrp Page 1 Wrogo Building Analysis t�,u Entire House • - • • For: ST. JOHN'S INTERIOR Job: Date: Mar 24, 2007 By: G.CARMACK Desigii"Conditions Location: Fort Pierce, FL, US Indoor: Indoor temperature (°F) Heating 70 Cooling 75 Elevation: 25 ft Latitude: 27°N Design TD (°F) Relative humidity (%) 28 30 15 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 1.1 61.5 Dry bulb (OF) 42 90 Infiltration: Daily range l-F) - Wet bulb (OF) - Wind speed 15 ( L) 78 Method Construction quality Simplified Average ((mph) 15.0 7.5 Fireplaces 0 " °a . H�eati'ng Component Btuh/ft2 Btuh % of load Walls 2.8 6455 22.4 Glazing 35.6 5014 17.4 Doors 10.9 415 1.4 Ceilings 1.4 2125 7.4 Floors 10.6 6132 21.3 Infiltration 1.3 3235 11.2 Ducts 2338 8.1 Piping 0 0.0 Humidification 0 0.0 Ventilation 3077 10.7 Adjustments 0 Total 28791 100.0 3 Coolin Component Btuh/ft2 Btuh % of load Walls 2.5 5787 19.6 Glazing 89.5 12624 42.8 Doors 11.3 430 1.5 Ceilings 2.6 3985 13.5 Floors 0.3 168 0.6 Infiltration 0.4 912 3.1 Ducts 2529 8.6 Ventilation 1649 5.6 Internal gains 1380 4.7 Blower 0 0.0 Adjustments 0 Total 29462 100.0 Overall U-value = 0.158 Btuh/ft2-°F WARNING: suspicious slab -on -grade floor perimeter in BDR #3. GWft C,,t, wrightsofr Right -Suite Residential 6.0.90 RSR21115 2007-Sep-0513:15:38 ACC& CADocuments and Settingsl9cannackft DocumentslMan J Calcs 20071FT.PIERCEIST. JOHN'S INTERIOR.np Page 1