Loading...
HomeMy WebLinkAboutSwimming Pool PlanWATERLINE i 6" MIN. GUNTI'E 0 UNDISTURBED OR COMPACTED L SOIL TO 95% MODIFIED 6" MIN.GUNITE PROCTOR 4000 PSI 03 @12" OC/ BW FOR DEPTH TO 5' #3 @ 6" OC/ BW FOR DEPTH> 5' Ate -ENTRAPMENT MAIN DRAIN _ rPOOL SECTION - 30 NOTE: COPING EDGE MAY VARY FROM SQUARE (BUFFED OR TUMBLED) TO SINGLE B/N �^ TO BOUBLE B/N �- 1 4"CONCRETE 1/4% 3/8" - BRITE DBN BRICK 4"CONCRETE SWIMMING POOL PLAN SCALE: 1/8"=1'0" V) 1®X� 0 DTI 5 Err 00 ® r- � 0 =zz 0X, I CANTI-LEVER MARBLE DBN BRICK PAVER IM PRICK PAVER / CONCRETE ON CONCRETE OR MARBLE ON SAND W ONCRETE SPRAY DECK OVER -POUR WALL SECTIONS SEW EY KO P.E #16668 SCREEN ENCLOSURE SWIMMING POOL PLAN FOR: `,\x,,l0 Yj VNF� 5/8"ORBETTERPLYWOOD SHEATING ENORQEERBQO(BY OTHERS) 2"X4"X 8" @ 2' OC HRICK PAVERS I o � 1 ' FIMSHEDGRADE �Lr/�`, �I�R�lAVE _® i NO.16668 '* Z' OR R 5 STEEL '•' bnl:::1 12" _ .. _ ® .®� i� OR 145 RE -STEEL CONTINUOUS " �'' `� STATE O . SHORING DETAIL S//�� OFil�p%�,G� FOOTER DETAIL O N�_ FOR SCREEN ENCLOSURE sIlSs`��OW 2500 PSI CONCRETE W/6"X6" # 10/10 STEEL WME MESH OR FIBER MESH, (11bND.) + 0-0 0-0 0-0 0-0 0 0. —ygi- 4" 3-93 RE -STEEL �8 I f OR 1 #5 RE -STEEL I _ CONTINUOUS FOOTER DETAIL FOR SCREEN ENCLOSURE EL-SID ENGINEERING #EB-0006831 139 ISLE VERDE WAY PALM BEACH GARDENDS, FL 33418 FOR: 39�5 ALL WE 5E'Ply\ _'_5 UNDISTURBED SOB. (NO EXCEPTIONS SWIM IN BENCH DETAIL SWIM OUT BENCH DETAIL NTS NTS DRAWN BY: SHEET 1 OF 3 DATE: I JOB NO: C joon w r- me 00 rn own in in �.�o�a c0 VALVE ov 40 PIPE SCHEMATIC SCALE NTS WATER LEVEL 6" MIN-12" MAX C VAC LOCK #W400 FB FBC 2017 SEC 459.1.6.5.3.2 & ANSI/ASME A112.19.8M FILTER W/ PRESSURE GAUGE & AIR RELEASE VALVE WASTE RETAINED ON SITE PUMP W/HAIR & LINT STRAYER 293 6 TO PUMP SKIMMER & VAC DETAIL SCALE NTS PIPING DIAGRAM SCALE NTS POOL PIPE SIZE FLOW (8/sec) FLOW THRU CMP MD GRATES n PIPE FLOW MAIN DRAIN 2 7. f SKIMMER U" RETURN TO POOL/SPA 2 7� ASSUMPTION: POOL FLOW 67% MD 33% SKIMMER SPA FLOW 100% MD POOL RETURN FROM PUMP FROM TEE, 1-1/2" AT INLET T 12" L 3-TREAD LADDER N.T.S. X ANCHORS ANCHORS i 1 j # 8 GROUND`, UND WIRE TYP I WIRE HANDRAIL. & STEPS (240-SQ. IN. MIN.) N.T.S. 4" CONCRETE SLAB OR PAVERS POOL EQUIPMENT SECURED W/1- 3/4" X 3/8" TAPCONS OR EQUAL. POOL EQUIPMENT/ANCHOR DETAIL SCALE NTS ANSI / APSP 7 ICC 7 EL-SID ENGINEERING CNIPFBCR4501.6.6 #EB-0006831 `�\ae BEY KO�N 32" CHANNEL DRAIN 139ISLE VERDE WA g\�,- C-ENS , r PALM BEACH GAQW-ND '�'��33418 F �i 32 CHANNEL DRAIN e= - - 7 No. 16668 OPEN AREA= 38.79 IN2 on FLOW RATE VERIFIED MAY 2011 TO CPSC TEST PROTOCOL r '0 i CC STATE OF ZZ IAPM0 LISTED FLOW RATES 0 �% O FOR 2.5" PLUMBING USING TWO OUTER PORTS=308GPM (FLOOR) & 212 GPM (WALL) / �� �'�.� ORI� P%,�GN `-% O FOR 2.5" PLUMBING USING CENTER PORT ONLY = 200 GPM (FLOOR) & 168 GPM (WALL) v/�s�0(VAL1�?�0\\\ 0.1 FOR 2" PLUMBING USING TWO OUTER PORTS = 268 GPM LO 1 w (F OR) & 92 GPM (WALL) 0 FOR 2" PLUMBING USING CENTER PORT ONLY = 184 GPM (FLOOR) & 176 GPM (WALL) DRAWN BY:. SHEET 2 OF 3 MAIN DRAIN DETAIL I DATE: JOB NO: 'NOTES:' , ; ONE OF THE FOLLOWING POOL SAFETY FEATURE OPTIONS MUST BE PROVIDED SPECIFICATIONS: I. THE POOL MUST BE ISOLATED FROM ACCESS TO A HOME BY AN ENCLOSURE THAT MEETS THE POOL BARRIER REQUIREMENTS OF 454.2.17 OF THE FLORIDA BUILDING CODE. 2. THE POOL MUST BE EQUIPPED WITH AN APPROVED SAFETY POOL COVER. 3. ALL DOORS AND WINDOWS PROVIDING DIRECT ACCESS FROM THE HOME TO THE POOL MUST BE EQUIPPED WITH AN EXIT ALARM THAT HAS A MINIMUM SOUND PRESSURE RATING OF 85DB AT 10 FEET. 4. ALL DOORS PROVIDING DIRECT ACCESS FROM THE HOME TO THE POOL MUST BE EQUIPPED WITH A SELF -CLOSING, SELF -LATCHING DEVICE WITH A RELEASE MECHANISM PLACED NO LOWER THAN 54 INCHES ABOVE THE FLOOR. *APSP-15 1 MINIMUM FLOW FOR 6 HOUR TURN OVER J GPM @ MINIMUM FILTER AREAS ® CARTRIDGE 190 F7x< ❑ SAND rr2 < ❑ DE Q �rFTz< g FILTER PUMP ��P�' T � # 51 11��RQ V 12 ELECTRIC RISER DIAGRAM HOUSE PANEL 200 POOL PANEL LITES 1P20 2P20 PUMP 0 2/0 1 2P60 POOL AUTOMATION AIRBLO\ TO POOL PANEL ELECTRIC TV PVC HEATER LPL 29CLZ 1P 15 GAS HEA 1#8N 1# 30GRD ELECTRICAL DIAGRAM 60AMP POOL PANEL MANUEL MOTOR STARTER SWITCH W/ 246 & 1#8 CU WITHIN Obi 110 HP PUMP MOTOR, W/ BUILT-IN V MIN. ELECTRICAL CONDUIT. OVERLOAD SWITCH W/- 2#6& I#8 CU WITHIN 1" MIN. CONDUIT #8 SOLID 'CU GROUND WIRE TO EXISTING PANEL S.P.S.T. TOGGLE SWITCH POOL LIGHTS) L-12. VOLT TRANSFORMER PFI NOT REQUIRED) JUNCTION BOX P--(GFCI PROTECTED) TIME CLOCK WP DISCONNECT 1. ALL ELECTRICAL TO COMPLY WITH 2O14 NATIONAL ELECTRIC CODE. ELECTRICAL CONTRACTOR TO VERIFY ADEQUATE CAPACITY AT POINT OF CONNECTION. 2. 3-#12 THHN CU WITHIN V MIN. CONDUIT FOR POOL LIGHT(S). 3. GROUND ALL BOXES, LIGHTS, MOTORS, ETC. W/#8 SOLID BARE COPPER. 4. PROVIDE W.P.G.F.I.OUTLET 10' MIN. - 20' MAX. FROM WATER'S EDGE. 5. ALL POOL PUMPS TO BE GFCI PROTECTED PER NEC 680.22(B)-2014. 1. THESE ENGINEERING PLANS COMPLY WITH 6th EDITION FBC 2017. SEC R 45011 SEC 454.1/ RIO1.2.1 PRIVATE SWIMMING POOLS. ENGINEERING DESIGN, CONSTRUCTION AND WORKMANSHIP PER ANSTINSPI-4-92 & NSPI -5. ANSI/APSP -15,7. ANSI/NSPI -3. ANSI/ASPC/ICC-4,5,6. 2. GUNITE TO ATTAIN 4000 PSI @ 28 DAYS. 3. RE -STEEL TO BE' INTERMEDIATE GRADE 40 ASTM 615 STANDARDS, PLACED TO ACI STANDARDS. 4. PIPING & PLUMBING TO BE SCH. 40 & 80 PVC PIPE TO CONFORM TO NSF STANDARDS & FBC 454.2.3,2.13.2 „ PURPLE PRIMER APPLIED PRIOR TO ALL GLUE JOINTS FBC PLUMBING SEC. 6.05.21 WATER PLUMBING 4, . PRESSURE 35 PSI FOR 15 MINUTES (NO AIR PRESSURE) SEC. 454.2.12.1. 5. ALL RE -STEEL, LITES, LADDERS & HANDRAILS BONDED W / #8 GROUND WIRE TO NEC. # 680 / 2014. 6. SOIL STATEMENT: SWIMMING POOL/SPA/PATIO - BEARING PRESSURE 2500 PSF. MINIMUM. 7. POOL/SPA SURROUNDED BY SCREEN ENCLOSURE OR 4' FENCE WITH SELF -CLOSING GATES. HOUSE SAFETY, BARRIER TO BE " BABY" FENCE OR ALARM SYSTEM PER CODE. 8. POOL/SPA HEATER INSTALLATION ION TO FBC. 2.14.1 HEATER TO HAVE THERMOSTAT AND HIGH PRESSURE"-, CONTROL TO LIMIT WATER TEMPERATURE TO <104°F. FBC. SEC. 454.2.14.4. 9. ALL GAS PIPING TO FBC. FUEL GAS SEC. 24.2.25 / ALL ELECTRICAL TO NEC. #680 / 2014. 10. AFTER COMPLETION, THE POOUSPA MUST NEVER BE DRAINED BY THE HOMEOWNER FOR ANY REASON' WHAT -SO -EVER. A LICENSED POOL CONTRACTOR MUST BE CONSULTED TO ACCOMPLISH THIS. HYDRO -STATIC RELIEF VALVE IS USED AT ENGINEER'S DISCRETION ONLY. BACK FLOW PREVENTER ON WATER SERVICE (WPB ONLY) I LTHE POOL/SPA EQUIPMENT SHALL BE SECURED TO A SUBSTANTIAL PAD SO AS TO ELIMINATE STRAIN ON PIPING. 12. TYPE'O' POOL WALLS VERTICAL WITHIN 110, DRAINAGE POOL/PATIO TO GRASS (PBC). 13. EL-SID ENGINEERING ASSUMES NO RESPONSIBILITY FOR POOL CONSTRUCTION IN EASEMENTS, OR REQUIRED SETBACK AREAS, THE POOL CONTRACTOR SHALL VERIFY ALL LAYOUT DIMENSIONS IN FIELD •a._ WITH HOUSE AND LOT LINES PRIOR TO CONSTRUCTION; ADDITIONALLY, UNDER AND OVER GROUND UTILITIES AT SITE.. WATER EDGE SHALL BE IO' MIN. (HORIZONTAL) FROM OVER HEAD ELECTRIC LINES. 14. THIS ENGINEERING PLAN REMAINS THIS SOLE PROPERTY OF EL-SID ENGINEERING AND IS NON-TRANSFERRABLE TO ANYONE WITHOUT EXPRESS PERMISSION OF THIS ENGINEER. 15. WARRANTY: THIS ENGINEER WARRANTS THE SERVICES PERFORMED BY EL-SID ENGINEERING ARE CONDUCTED IN A MANNER CONSISTENT WITH THAT LEVEL OF CARE AND SKILL ORDINARILY EXERCISED B'I" , MEMBERS OF THIS PROFESSION CURRENTLY PRACTICING UNDER SIMILAR CONDITIONS. NO OTHER ,4V3;,: , WARRANTIES EXPRESSED OR IMPLIED ARE MADE 16. ANGLE OF REPOSE CRITERIA (ST. LUCIE COUNTY) FOR POOL LESS THAN Y FROM HOUSE: (1) #3 RE -STEEL @ 6" OCBW- (2) GUNITE THICKNESS 6" MINIMUM. POOL DATA & EQUIPMENT & CRITERIA: l `� l POOL DIMENSIONS � V ' 3 V AREA PERIMETER 90 DEPTH VARIATION - VOLUME I f �w GALLONS SPA DIMENSIONS RAISED W/ JACUZZI JETS �^ LITES POOL/SPAP ®MP - SUr(� FIFLoyS FILTER ?-CC rC 159 PUMP VL HP -70 GPM � � TPA TURNOVERRATE - HRS LITES 1 HEATER dA 1 TU FUEL HANDRAIL 9zlRwsWIM-�-IN10 Dag DIAMOND BRITFJGEM COAT S II������ COLOR SLIDE DIVING BOARD AUTO -VAC CLEANER INLINE CL2 (BEN -FA I R SHEER DESCENT WATER FALL LIONS HEAD/ROSETTE "'" POOL BOND .PATIO lob LISTED 40YZ 40YZ 1�INSTALL IN SKIMMER PB 2008 • USING PROPER SIZED PLASTIC BUSHINGS, POOL BOND CAN BE INSTALLED IN ONE OF THE THREADAD SKIMMER OUTLET PARTS. SEE *ASSEMBLY PROCEDURE* FOR PROPER LIGHTENING OF POOL BOND, QINSTALL IN A RETURN LINE: • POOL BOND CAN BE INSTALLED IN THE FILTRATION RETURN LINE ADJACENT TO INLET FITTING AVOID INSTALLATIONS THAT COULD TRAP AIR. • IF ACCESS IS REQUIRED FOR SERVICE PURPOSES, A SPRINKLER SYSTEM VALVE BOX CAN BE USED FOR ACCESS. DO NOT INSTALL AS SHOWN TRAPPED AIR WILL PREVENT PROPER CONTACT WITH WATER (2)INSTALL ON SUCTION SIDE ADJACENT TO EQUIPMENT PAD: PUMP FILTER • INSTALL ON SUCTION SIDE PLUMBING AT LEAST 3" BELOW WATER LEVEL. r� r, • IF ACCESS IS REQUIRED FOR SERVICE PURPOSES, A SPRINKLER SYSTEM VALVE BOX CAN BE USED. WIRE RECEPTOR TAB POOL BOND CASTING #8 SOLID COPPER BONDING WIRE SPLIT BOLT V MALE PIPE THREAD EQUI-POTENTIAL; BONDING GRID NEC 680.26 (C) 2014. ALTERNATIVE METHOD PER FL. SENATE BILL SR 2836 EXECUTIVE ORDER 2007-187 SIGNED JUNE 19, 2007 FBC.101.2.1 SINGLE 48 AWG BARE SOLID COPPER WIRE AROUND ENTIRE PERIMETER OF POOL AND CONNECTED TO POOL RE -STEEL IN 4-EQUALLY SPACED PLACES FROM 48 SOLID INSULATED TAILS AND CONNECTED W/APPROVED MECHANICAL FASTENERS i.e., SPLIT BOLT, BRONZE PIPE CLAMP (WBRONZE SCREWS). EOUI-POTENTIAL BONDING #8 SOLID GROUND WIRE SHALL BE POSITIONED 4" TO 6" INTO SUBGRADE MATERIAL ADJACENT TO POOL STRUCTURE. THIS #8 WIRE SHALL BE BONDED TO POOL STRUCTURE REBAR IN 4 EQUALLY SPACED POINTS. THIS #8 WIRE SHALL BE PLACED 18" TO 24" IN PROXIMITY TO POOL STRUCTURAL WALL. LED LIGHT - LED LIGHT DETAIL PAD. RECOMENDED 3" BELOW WATER LEVEL MATERIAL rMA� W/DOD SCREEN ENCLOSURE gp FENCE ALARALARM/BARRIERPOOL Ag A0 AUTOMATION p� ,,...8 ® ppp�nj - r e,e.. ♦ ♦ 0 � i IJnow M o C� c? �®0 -40 m< 7� ,e T PIPE REDUCED TO 1" EL-SID ENGINEERING AND RUN TO DECK BOX #EB-0006831 139 ISLE VERDE WAY PALM BEACH GARDENDS, FL 33418 2" SCH 40 PVC SLEEVE SP 10-22 WALL FITTING- OR EQUAL INSTALLED INSIDE PIPE 4"-6" 1811-2411 GRADEFORPAVER OR CONCRETE DECK NTS �\\�'\oN�c i��i���� ,�X No. 16668 STATE OF :ir� �l0 DRAWN BY: v I SHEET OF 3 DATE: JOB NO: B