HomeMy WebLinkAboutProduct Approval (2) _ ---~' wGE....
Florida.Binding Code OnlineLed—
http:llwww.flari� ilding.org/PrtjPr apP dtl.aspx?param= ;
BM Home tog In i User Reg[stratlon I Hot Topics Submit Surcharge I Stats&Facts ' Publications i FBC Staff i BM Site Map ; Links Search I
Businesst
Professibna# i" s ER:Pub"User- �
I �'_ ER:Pubik User
Re ulation , m
C �: �oduct Approval Menu>Product or Application Search>Application List>Applkedon Datell
FL# FL10450-117
Application Type Revision
Code Version 2014
Application Status Approved � Gr� r•,�
Comments
Archivedt
Rtoduct Manufacturer Tams Roofing
THESE PLANS ANDA6?A Q&5@1JNfl9i-, one Information way
ARE SUI�IEtT O V Y f;OTT"t- CTIONS Suite
Little Rock,AR 72202
REQUIREP CR,*(NELD MOVC-oC ORS THAT (254)913-7750
MAY Edi NE;0�� ARA IN
Wi5R To � smohseen@tarroroaflng.cam
QtQNtKY WIDI A.UA4tSPrdAAtuU9PE8t V Shaik Mohseen
smohseen@tarcoroofing.com y —
Tec hni ai Representative Shaik Mohseen
Address/Phone/Email 2403 Taylors Valley Road ST L U C I E COUNTY
Belton,TX 76513 BUILDING DIVISION
(254)913-7750 REVIIrWED
s^mohseen@tarcoroofing.cam FOR C®nPL A�
REVIEWED
B
Quality Assurance Representative Shalk Mohseen DATE PLAN ANDD&Rt�IT
Address/Phone/Emall 2403 Taylors Valley Road IMUST E KiwKr1`ON JOB O
Belton,TX 717 NO INSPRO ION ilii" dE f'�"�:rl
(254)939-337775 Ext 210
smohseen@tarcoroonng.com
Category Roofing
Subcategory Underiayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert leminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC v w=,. `,i
Quality Assurance Contract Expiration Date 10/13/2017
Validated By John W.Knezevk:h,PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL10450 R7 COI 2015-01 COI Nleminen.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2009
ASTM D226 2006
W11V 6 I.
ARE THE RESPONSI 1 RY OF THE
Of 2 CONTRACTOR OF RECORD 4/19/16,,10:03 AM
Florida Building Code Online fir_ http!lwww floe wilding.org/prlpr_app_dd.aspx?param�avGE:.
ASTM D3909 1997
ASTM D4869 2005
ASTM D6164 2005
ASTM D6380 2003,
FM 4474 2004
FRSA/TRI April 2012(04-12) 2012
TAS 103 1995
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1,Option D
Date Submitted 12/17/2015
Date Validated 12/17/2015
Date Pending FBC Approval 12/21/2015
Date Approved 02/10/2016
Date Revised 04/18/2016
Summary of Products
FL# Model,Number or Name Description
10450.1. Tarco Roof.Underiayments Roof.underlayments for use in prepared roof assemblies
Limits of Use Instaiiation Instructions
Approved for use in HVHZ:No Fi_10450 P7 II 2015 12 FINAL ER TARCO UNDERLAYMENTS FL10450-
Approved.for use outside HVHZ:Yes R7.odf
Impact Resistant-N/A Verified By:Robert Nieminen PE-59166
Design Pressure:+N/At-217.5 Created by Independent Third Party:Yes
otfier:1.)The design.pressute herein pertains Evaluation Reports
to one particular bonded underlayment EL1tki50 R7 AE 2015 12 FINAL ER TARCO UNDERLAYMENTSS FL10450-
application for use beneath adhesive-set file SZ plff
'systems.Refer to ER Section 5.6.2 for details, Created by Independent Thins Party:Yes
and other bonded underiayment systems.2.)
Refer to ER Section 5 for Umits of Use.
sack rmxt
Contact Us;;19M NOttir Monroe Street Tallahassee FL 32349 Phone:_8cn-487-r n_!
The State of Florida is an AAJEEO employer.�oovMaht2�7-,�Oj Mate of fiorida.::Privacy Statement::Accessibility statement::)�,-ruAd staxement
Under Florida law,emali addresses are public records.If you do not want your e-mail address released In response to a pubiio-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant o*section
ass.27s(,11 FMortda statutes,effective October 1,:2822,licensees licensed under chapter 455,F.S.must provide the Department with an email address If they have
one.The emails provided maybe used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a
personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under chapter
455,F.S.,please crick(l=.
Product Approval Necapts:
M® EL'tE:i M.
�Cc:Ur'It\'tit t:(}Lti'
Of 2 4/19/16,10:03 AM,
EXTERIOR RESEARCH&DESIGN,LLC.
Certificate of Authorization 1#9503
`� I 353 CHRISTIAN STREET,UNIT#13
-�j $ W J �E � OXFORD,CT 06478
PHONE:(203)262=9245
FAX:(203)262-9243
EVALUATION,REPORT
Tarco Roofing Evaluation Report 10880.07:08-117
One Information Way,Suite 225 F1.10450-117
Little Rock,AR 72202 Date of Issuance:07/11/2008
Revision 7:12/17/2015
SCOPE:
This. Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the.State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E.for
use of the product under the Florida Building Cade and Florida.Building Code, Residential Volume. The.products described
herein have been evaluated for compliance with the 5th Edition(2014)Florida Building Code sections noted herein.
DESCRIPTIoN: Tarco:Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named products) changes, the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. Trinity(ERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADvERTISEMEur The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in.
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request,a copy of this entire Evaluation Report shall be.provided to the user by the manufacturer or its
distributors and'shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 10.
Prepared by:
Robert J.M.Nieminen �= Thefacsimlesea)
+,P.E. �afi•�.;�'!^� _� ,'� appearing was authorized by Rober[Nieminen,
��iS "•' "4? �� P.E.on 12/17/2015.This does not serve as an electronically signed
Florida Registration No.59166,Flarlda OC4ANE1983 ;ry,��0\�.t �k. document Signed,sealed hardmPies have been transmitted to the
..... " Product Approval Administratorand to the named client
CERTIFICATION OF INDEPENDENCE:
1. Tnnity.I ERD does.not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity ERD.1s.not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E,does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does.not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,isjwas used for permitting or design guidance unless retained
specifically foe that purpose.
f t 4.j
a `5. 1 TRIN11Y ER®
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: U nderlayment
Compliance Statement: Roof Underlayments, as producedby Tarco, have demonstrated compliance with the
following sections of the Florida Building Code, through testing in accordance with the following Standards.
Compliance is subject to-the Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Prope Standard Year
1504.3.1 Wind Uplift FM 4474 2004
1507.2.3,1507.3.3,1507.5.3, Physical Properties ASTM D226. 2006
1507.7:3,1507.8.3,1507.9.3
1507.2.3;1507.2.8,1507.4.5.1, Physical Properties ASTM D4869 2005
1507.4.5.2,1507.5.3,1507.5-.3.2,
1507:7.3,1507.7.3.2,1507.8.3,
1507.8.3.2,1507.9.3,1507.9.3.2
1507.2.4,1507.2.9.2,1507.5:3, Physical Properties ASTM D1970 2009
1507.7.3
1507.2.9.2 Physical Properties ASTM D3909 1997
1507.2.9.2,1507.3.3 Physical Properties ASTM D6380 2003
1507.3.3 Installation Practice FRSA/TRI April 2012(04-12) 2012
1507.11.2 Physical Properties ASTM D6164 2005
1523.6.5.2.1 Physical Properties TAS 103 1995
3. REFERENCES:
Enti Examination Reference Date
ERD(TST6049) ASTM D6164 T6470.08.07-R1 08/30/2007
ERD(TST6049) FM 4474 T6460.06.07-111 10/09/2007
ERD(TST6049) ASTM D1970 T30160.08.09 08/14/2009
ERD(TST6049) TAS 103 T33190.08.10 08/06/2010
ERD(TST6049) ASTM D1970 T32530.08.10 08/17/2010
ERD(TST6049) FM 4474 T37610.07.11 06/29/2011
ERD(TST6049) ASTM D3909 T40780.04.12 04/06/2012
ERD(TST6049) ASTM D6380 T40790.04.12 04/06/2012
ERD(TST6049) TAS 103 T35410.04.12 04/18/2012
ERD(TST6049) ASTM D1970 745250.04.13-112 04/23/2013
ERD(TST6049) Physical Properties T43930.09.13-R2 09/11/2013
ERD(TST6049) Physical Properties TAR-SC9480JS 07/02/2015
ERD(TST6049) Wind-FM4470/4474 TAR-SC5670.14 12/03/2015
ERD(TST6049) Wind-FM4470/4474 TAR-SC8020.14 12/03/2015
PRI(TST5878) ASTM D1970 BRY-018-02-01 08/11/2003
PRI(TST5878) ASTM D1970 BRY-017-02-01 08/11/2003
PRI(TST5878) ASTM D226 TOT-014-02-02 05/18/2004
PRI(TST5878) ASTM D226 TOT-015-02-02 05/24/2004
PRI(TST58,78) ASTM D6380 TOT-029-02-01 07/05/2005
PRI(TST5878) ASTM D4869 TOT-009-02-01 09/14/2004
PRI(TST5878) ASTM D4869 TOT-009-02-02 09/14/2004
PRI(TST5878) ASTM D226 TOT-041-02-01 05/24/2006
Miami-Dade(CER1592) FBC HVHZ Certification 12-0420.02 10/03/2013
Tarco Roofing Adhesive compound Affidavit 12/15/2015
UL,LLC.(QUA9625) Quality Assurance Service Confirmation Exp.10/13/2017
Exterior Research and.Design,LL[. Evaluation Report 10880.07.08-R7
Cerb"ficate of Authorhatlon#9503 121.10450-R7
Revision 7:12%17/2015
Page 2 of to
J
`., TRINITY ERR
4. PRODUCT DESCRIPTION:
4.1 Self-Adhering Underlayments:
4.1.1 LeakBarrier Fast90 Self-adhering Tile Underlayment is an asphalt-saturated organic felt coated on both
sides with asphalt and surfaced on the top side with mineral granules,and on the underside with a self-
adhering compound and release film.
4.1.2 LeakBarrier MS300 Ice and Water Armor is a self-adhering, glass mat reinforced, mineral surfaced, SBS
modified roof underlayment.
4:1.3 LeakBarrier PS200"r Ice and Water Armor is a self-adhering, glass mat reinforced, fabric surfaced, 5BS
modified roof underlayment.
4.1.4 LeakBarrier PS200mu Ice and Water Armor is a self-adhering, glass mat reinforced, smooth poly film
surfaced,SBS modified roof underlayment.
4.1.5 LeakBarrier NR50e is a self-adhering,plastic film surfaced,modified underlayment.
4.1.6 LeakBarrier SS400 Ice and Water Armor is a self-adhering, fiberglass reinforced, smooth surfaced
modified.underlayment.
4.2 Mechanically Fastened Underlayments:
4.2.1 Tarco 15 is an ASTM D226 Type 1,15.1b asphalt-saturated organic felt
4.2.2 Tarco 30 is an,ASTM D226 Type 11,30 Ib asphalt-saturated organic felt
4.2.3 Tarco NO 30 is an ASTM D4869 Type II asphalt-saturated organic felt
4.2.4 LeakBarrier EasyLay is an asphalt-coated polyester fabric roof underlayment.
4.3 Mechanically Fastened and/or BondedUnderlayments:
4.3.1 Fiberglass Mineral Surfaced Roll Roofing is an ASTM D3909, glass-fiber-reinforced, asphalt-coated,
granule surfaced underlayment used as a valley liner.
4.3.2 ASTM Organic Mineral Surface Tile Underlayment is an ASTM,D6380, Class M asphalt-saturated organic
roll roofing sheet.
4.3.3 LeakBarrier EasyMopl SBS is a,polyester reinforced,SBS modified bitumen roofing underlayment.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way; the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used:for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing, Materials
Directory for fire ratings of this product.
5.4 Tarco Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made to the AHJ for approval
based on this evaluation combined with supporting data for the prepared.roof covering.
5.5 Allowable roof covers applied atop Tarco underlayments are follows:
.:.', TABLE_l_ROOECOVER,OPTIONs . _ ,.: _
Underlayment Asphalt Nail-On Tile Foam-On Tile Metal Wood Shakes Slate
Shingles &Shingles
LeakBarrier Fast90 Yes Yes Yes No Yes Yes
See 5.5.2
LeakBarrier M5300 Yes No No No Yes Yes
LeakBarrier.PS200"' Yes Yes Yes Yes Yes Yes
See 5.5.2
LeakBarrier P5200mu Yes No No Y Yes Yes
Exterior Research and Design,LLC. rat n Report 10880.07.08-R7
Certificate ofAUthorization#9503
F1.10450-0
Revision 7:12/17/2015`
Page 3 of 10
?
�.., t x.16 I ERD
. TABLE 1, RaoF CQVER OPTIONS
Underlayment Asphalt Nail-On Tile Foam-On Tile Metal wood Shakes Slate
Shingles &Shingles
Yes
LeakBarrier NRSCe Yes No No (No copper or Yes Yes
zinc)
LeakBarrier SS400 Yes No No No Yes Yes
Yes Yes
LeakBarrier EasyLay Yes (as base sheet in (as base sheet in Yes Yes Yes
2-ply system) 2-ply system)
LeakBarrier EasyLay yes Yes Yes Yes Yes Yes
UDL Basic or UDL 50 (See FL16884) (as base sheet in (as base sheet in (See FL16884) (See FL1688N) (See FL16884)
2-ply system) 2-ply system)
Tarco 15 Yes No No Yes Yes No
Yes Yes
Tarco 30 Yes' (as base sheet in (as base sheet in Yes Yes Yes
2-ply system) 2-ply system)
Tarco NO 30 Yes No No Yes Yes Yes
(double layer) (double layer) (double layer) (double layer)
Fiberglass Mineral Yes
Surfaced Roll Roofing Valley liner per No No No No No
1507.2.9.2(2)
ASTM Organic Mineral
Surface Tile Yes Yes Yes No Yes Yes
Underlayment See 5.5.2
S kBarr(er EasyMop y� Yes See Yes
s 2I i
No Yes Yes
5.5.1 Tarco 15,Tarco 30,Tarco.NO 30 and EasyLay may be used as a mechanically attached base layer followed
by a LeakBarrier self-adhering top layer or asphalt-applied ASTM Organic Mineral Surface Tile
Underlayment or LeakBarrier EasyMop$BS with allowable roof covers noted above for the respective top
layer underlayments.
5.5.2 "Foam-On Tile" is limited to use 'of 3M 2-Component Foam Roof Tile Adhesive AH-160 (FL6332).
applications unless tensile adhesion / long term aging data from an accredited testing laboratory is
provided.
5.6 Allowable Substrates:
5.6.1 LeakBarrier self-adhering direct-bond to deck:
D New untreated plywood(unprimed or primed with ASTM D41 primer);
➢ Existing plywood(unprimed or primed with ASTM D41 primer);
➢ New or existing OSB(unprimed or primed with ASTM D41 primer);
➢ Structural concrete(unprimed or primed with ASTM D41 primer).
Note: Tarco does not require priming of new or existing plywood or OSB sheathing. New or existing
,plywood or.OSB sheathing should be cleaned of all dirt and debris prior to application:of LeakBorrier
membranes.
ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier EasvMop SBS Direct-Bond to Deck:
➢ ASTMD41 primed structural concrete.
Note:Refer to 5.6.4 for uplift limitations associated with direct-deck underlayment installations where the
overlying roof cover is foam-on tile roofing.
1 L y
Exterior Research and Design,I.I.C. Evaluation Report 10880.07.08-R7
Certificate of Authorization J795Q3 FL10450-R7
Revision 7:12/17/2015
Page 4 of 10
N 11
TRI 'ERD
NITY
5.6.2 Band toMechanically Attached Base.Sheet
LeakBarrier self-adhered to:
➢ ASTM D226,Type I or 11 felt;
> ASTM D4869 felt;
> LeakBarrier EasyLay.
ASTM Organic Mineral Surface file Underlayment or LeakBarrier EasyMop SBS in hot asphalt to:
> ASTM D226,Type I or 11 felt;
> ASTM D4601,Type 11 base sheet
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam-on tile systems,base layer shall be attached
per minimum requirements of FRSA/TRl April 2012(04-12).
5.6.3 LeakBarrier Self-Adhering Bond to Other Substrate Types
> ASTM D41 primed metal(flashing metal,valley metal,etc.')
5.6.4 Wind Resistance for Underlayment Systems in-Foam-On Tile Applications-: FRSA/TRl April 2.01-2.(04-12)
does not address wind uplift resistance of all yunderla ment systems beneath foam-on tile systems,where
.
the underlayment forms part of the load-path. The following wind.uplift limitations apply to underlayment
systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam-on tile applications.
Maximum Design Pressure is,the result of testing for wind,'load resistance based on allowable wind loads,
and reflects the ultimate passing pressure divided by 2 (the 2 to I margin of safety per FBC 1504.9 has
already been applied).Refer to FBC 1609 for determination.of design wind loads.
5.6.4.1 Maximum Design Pressure=-75.0 a
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ
Primer: (Optional)ASTM D41
Base Ply- (Optional)LeakBarrier PS206W,self-adhered.
Underlayment* LeakBarrier PS20011Tr self-adhered.
5.6.4.2 Maximum Desitin Pressure=420.0 psf
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ
Primer. (Optional)ASTM D41
Joint Treatment: Plywood joints are covered with 4-inch.wide strips of LeakBarrier PS200mu or LeakBarrier Easy8ase,
rolled into place to create continuous bond
Base Ply- (Optional)LeakBarrier PS20e",self-adhered
Underlayment- LeakBarrier PS20e,self-adhered.
5.6.4.3 Maximum Design Pressure=-217.5 p :_
Deck:• Structural concrete to meet project requirements to satisfaction of AHJ.
Primer: (Optional)ASTM:D41 Mu'
Base Ply: (Optional)LeakBarrier PS200 .self-adhered
Underlayment: LeakBarrier PS200 ,self-adhered.
5.6.4.4 All other direct-deck, adhered' Tarco underlayment systems beneath foam-on tile systems carry a
Maximum Design Pressure of-45 psf.
5.6.4.5 Maximum Design Pressure=-45.0 psf*
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: LeakBarrier EasyLay UDL Basic or LeakBarrier EasyLay UDLSO(48"wide rolls);See FBC FL16884.
Fasteners; 12ga. x 1.25-inch long.x 3/8-inch head diameter annular ring shank roofing nails and 1-5/84nch
diameter tin caps
Spacing-, 6"o.c.at the 4-inch wide side laps and 8"o.c.atfour equally spaced,staggered center rows.
gase Ply: (Optional)LeakBarrier PS200MU,self-adhered
Underlayment: LeakBarrier PS20e,self-adhered.
Exterior Research and Design,LLC. Evaluation Report 10880.07.MR7
CL-rWicate of Authofizarlon#9503 FL10450-117
Revision 7:12/17/2015
Page 5 of 10
x--,JTRINITYIERD
5.6.4.6 Maximum Design Pressure=-60.0 psf.-
Deck: Min.19/32-Inch plywood to meet project requirements to satisfaction of AHI.
Base Sheet: LeakBarrier EasyLay
Fasteners: 12 ga. x 1.25-inch long-x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-Inch
diameter tin caps
Spacing: 7"o.c.at the 4-inch wide side laps and 1"o.c.at three(3)equally spaced,staggered center rows.
Base Ply. (Optional)LeakBarrier PS200 Mu self-adhered
Underlayment: LeakBarrier PS200HT"self-adhered.
5.6.4.7 Maximum Design Pressure=-60.0 P
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHI.
Base Sheet: LeakBarrier EasyLay UDL Basic or LeakBarrier EasyLay UDL 50(48"wide rolls);See FBC FL16884.
Fasteners: 12 ga. x 1.25-inch long x 318-inch head diameter annular ring shank roofing nails and 1-5/8-Inch
diameter tin caps
Spacing: G'o.c.at the 4-inch wide side laps and V o.c.at four(4)equally spaced,staggered center rows
Base Ply: (Optional)LeakBarrier PS200mu,'self-adhered
Underlayment: LeakBarrier PS200HT'self-adhered.
5.-6.4.8 Maximum Design Pressure=-82.5 nsf-
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHI.
Base Sheet: Leak!3arrier EasyLay
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9"o.c.at the 44hch wide side laps and 8"o.c.at four(4)equally spaced;staggered center rows.
Base Ply: (Optional)LeakBarrier PS200 Mu,self-adhered
Underlayment: LeakBarrier PS206w,sell-adhered.
5.6.4.9 Maximum Design Pressure=-120.0 nsf:
Deck- Min.15/32-Inch plywood to meet project requirements to satisfaction of AHI.
Base Sheet: WakBarrier EasyLay
Fasteners: 12 ga. x 1.25-Inch long x 3/8-Inch head diameter annular ring shank roofing nails and 1-5/8-inch
diameter tin caps
Spacing: 4"o.c.at the 4-inch wide side laps and 4"o.c.at four(4)equally spaced,staggered center rows.
Base Ply: (Optional)LeakBarrier-PS20e u,self-adhered
Underlayment: Leakftrrier PS20e',self-adhered.
5-6-4-10 For mechanically attached base sheet in a 2-ply system, the maximum design.pressure for the selected
assembly shall,at a minimum, meet or exceed the Zone 1 design pressure determined in accordance with
FRSA/TRI April 2012(04-12),Appendix A,Table IA or FBC 1609. Zones 2 and 3 shall employ an attachment
density designed by a qualified design professional to resist the elevated pressure criteria. Commonly
used methods are RAS 117, FIVI LPDS 1-29: and ANSIJSPRI WDI. Assemblies above marked with am
asterisk*carry the limitations set forth in Section 2.7.1.5.1(a)of FIVI LPDS 1-29 for Zone 2/3 enhancements.
5.7 Exposure Limitations:
5.7.1 LeakBarrier EasyLay,,FAST 90,,ASTM Organic Mineral Surface Tile Underlayment.and LeakBarrier EasyMop
SBS shall not be left exposed for longer than-180-days after installation.
5.7.2 LeakBarrier P5200 HT shall not be left exposed,for longer than 120-days after installation.
'5.7.3 Lea.kBarrier M5300, NR500 HT, P5200 Mu or SS400 shall not be left exposed for longer than 30-days after
installation.
5.7.4 Tarco 15,Tarco 30 and Tarco NO 30 shall I e covered as soon as possible after installation; exposure for
more than 24 hours after installation could adversely affect performance.
Exterior Research and Design,LLC. Evaluation Report 10880.07.08-R7
ceroficate ofAuffiorhadon#9503 FL10450-R7
Revision 7:12117/2015
Page 6 of 110
!Q
6. INSTALLATION:
6.1 Tarco Roof Underlayments shall be installed in accordance with Tarco published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2. Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application,and'primed the substrate(if applicable).
6_3 LeakBarrier®Fast90®Self-Adhering Tile Underlavment:
6.3.1 EasyLay shall be installed in compliance with the requirements for 90# felt underlayment (except the
product is self-adhered)in FBC Sections 1507 for the type of prepared roof covering to be installed.
6.3.2 Non-Tile Applications:
Cut the Fast90 roll into 12'to 16'sections for workability and allow to relax prior to application.
Chalk-.a plumbline 36"from all outside perimeters;then chalk plumb lines 32"apart,upslope to the ridge
line.
Membrane Application:
Place a full width piece of Fast90 on the prepared substrate,parallel to the eave edge of the roof,,with
the selvedge edge positioned upslope and in-line with the 151 chalk line.
➢ Fold back half the sheet and remove the exposed release film, taking care not to displace the.
membrane
A Working from the centerline out, roll the membrane onto the substrate,taking care to avoid wrinkles
and ridges,and repeat for the other half,of the sheet.
➢ Remove selvage release film,if present,and install capped or tin tagged nails 6"o.c..in the center of the
selvedge edge.
➢ Install the subsequent sheets in the same manner,with upslope selvedge edges in-line with chalk lines,
with 4"side laps and 8"end laps.
➢ Seal ail 8"end laps 1/16"thick application of asphaltplastic cement and stagger all end laps minimum.
36".
➢ Rolf the entire surface With a weighted roller,paying particular attention to side laps,end laps and eave
/rake areas to ensure a complete bond.
6.3.4 Tile Applications:
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.
Wait a minimum of 24 hours prior to loading roof tiles.
All tiles shall be staged four tiles perpendicular to slope,six tiles on top,parallel to slope; not to exceed 10
tiles total to a maximum roof pitch of 5:12 for flat tiles and 6:12 for lugged.tiles. If tiles are to be left in a
staged condition for more than 30 days,tiles shall be staged two tiles perpendicular to slope,four tiles on
top,parallel to slope; ;not to exceed 6 tiles total to a maximum roof pitch of 5:12 for flat tiles and 6:12•for
lugged tiles.
At roof pitch in excess of those noted above, the tiles shall be staged behind a nominal 1 x 2 horizontal
batten.
Bitenor Research and Design,LLC. Evaluation Report 10880.07.08-R7
Certificate ofAuthorfrotlon#9503 F1.10450-117
Revision 7:12/17/2015
Page 7 of 10
ERD
.4 LeakBarrier®MS300,PS200"T.PS2000°",NR500"T or SS400 Ice and Water Armor:
6.4.1 MS 300, PS200"r, PS200M", NRSOe or SS400 shall be installed in compliance with the requirements for
ASTM D1910 underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed..
6.4.2 Non-Tile Applications:
Cut MS 300, PS200"T, PS200M", N11500"T or SS400 to manageable sections and allow to relax prior to
application.
Membrane Application:
➢ Place a full width piece on the prepared substrate, aligned parallel to the eave edge and extend
approximately 3/8"over the eave and rake with the selvedge edge positioned upslope.
➢ Fold back the upslope half of the sheet and remove the exposed release film,taking care not to displace
the membrane
➢ Working from the centerline out, roll the membrane onto the substrate,.taking care to avoid wrinkles
and ridges
➢ Apply a 1/16" thick layer of asphalt plastic cement over the eave and rake metal, extending 2" to 3"
onto the deck surface.
➢ Fold back the downslope half of the sheet, remove the release film and roll the membrane onto the
substrate from the centerline out.
• Seal all 6" end laps with a 1/16" thick application of asphalt plastic cement and stagger all end laps,
minimum 36".
➢ Removeselvage release film,if present,and install second and subsequent courses in a similar manner.
Install capped or tin-tagged nails 6"o.c.along the centerline of the laps.
➢ At all T joints, where an end-lap and the next overlapping course intersect,apply a bead of roofing laps
cement before the overlapping course is laid.
➢ Roll the entire surface with a weighted roller,paying particular attention to side laps,end laps and eave
/rake areas to ensure a complete bond.
6.4.3 Tile Applications(PS200"T only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.
Wait a minimum of 24 hours prior to loading roof tiles.
All tiles shall be staged four tiles perpendicular to slope,six tiles on top,parallel to slope; not to.exceed 10
tiles total to'a maximum roof pitch of 5:12 for flat tiles and 6:12 for lugged tiles. If tiles are to.be left in a
staged condition for.more than 30 days,tiles.shall'be staged two tiles perpendicular to slope,four tiles ion
top;parallel to slope; not to exceed 6 tiles total to a maximum roof pitch of 5:12 for flat tiles and 6:12 for
lugged tiles.
At roof pitch in excess of those noted,above, the tiles shall be staged behind a nominal 1 x 2 horizontal
batten.
6.4.4 Two.(2)Ply Underlayment Svstems:
LeakBarrier®SS400 Ice and Water Armor followed by LeakBarrier°SS400 ice and Water Armor(direct-to-
deck,per 5.6.1 or over mechanically attached base sheet per 5.6.2)is allowable for use.under mechanically
attached prepared roof systems. Limits of use are those associated with the top-layer material. This is not
a requirement,but is allowable if a 2-ply underlayment system is desired.
w,ft" Aft
Exterior Research-and Design,LLC. Evaluation Report 10880.07.08-R7
Ce�cate of Authorizatlon 99503 FILL uOrmlyFL10450-R7
Revision 7:12/17/2015
Page 8 of 10
TR
I � .ERD
6_5 Tarco 15 and 30:
6.5.1 Tarco 15 and 30 shall be installed in compliance with the requirements for ASTM D226, Type I and 11
underlayments,respectively,in FBC Sections 1507 for the type of prepared roof covering to be installed.
6.5.2 Non-Tile Applications:
Reference is made to the current edition of the NRCA Steep-slope Roofing Manual.
6.5.3 Tile Applications,base laver in 2-olv system(Tarco 30 only).
Reference is made to FRSA/TRI April 2012(04-12)Installation Manual and Table 1 herein.
6.6 Tarco NO 30:
6:6.1 Tarco NO 30 shall be installed in compliance with the requirements for ASTM D4869,Type II underlayment
in FBC Sections 1507 for the type of prepared roof covering to be installed; 1507.4.5.2(1), 1507.5.3.2 (1),
1507.7.3.2(1),1507.8.3.2(I)-or 1507.9.3.2(1).
6.7 LeakBarrier EasyLay:
6.7.1 EasyLay shall be installed in compliance with the requirements for.ASTM D226;Type I or-if underlayment in
FBC Sections 1507 for the type of prepared roof covering to be installed.
6.7.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application.
6.7.3 Non-Tile Applications:
Place a full width section of EasyLay,parallel to the eave edge of the roof and unroll 2 to 3 feet with the lay
lines facing up,and position mthe edge of the eave and rake. Install a few fasteners at the top, near the
rake, and roll out the sheet to a manageable length. Pull, straighten and align the sheet so that any
wrinkles are eliminated and the sheet is even with the eave edge. Fasten-with 3/8"headed roofing nails or
1"capped (plastic or metal)nails,driven by hand or pneumatically,spaced 6" o-c.at all laps in the center
of the seam area,and two staggered rows fastened 12"o.c..in the field of the sheet. Install nails such that
the head of the nail is flush with the surface, without cutting into the surface. _Fasten from,the top to
avoid walking or kneeling on unsecured sheet. Continue to the end of the substrate and fasten down.
Align the next roll over the preceding sheet so as to form a minimum 4", water-shedding lap,and install
per instructions above. Apply subsequent sheets in the same manner, with minimum 4"water-shedding
laps and minimum 8"end-laps,which are staggered minimum 36"fro the preceding course.
For double layer applications, follow the instructions noted above, but using a minimum 19", water-
shedding side lap.
Allow for minimum 6"up the vertical transitions and minimum 6"over hips and ridges.
At valleys,first install a vertical length of EasyLay down.the center of the valley,then start at the low point
and work to the high point,rolling the membrane from the center outward in each direction, ensuring no
wrinkles or tears. Covered with valley-metal or other valley lining material in accordance with NRCA
recommendations.
Apply a thin coat of asphalt plastic cement to waterproof areas where any cuts or tears have occurred.
Seams or joints that require adhesive or sealant can be treated with high quality plastic cement(asbestos
free).
6.7.4 Tile Applications,base laver in.2-ply system:
Reference is made to FRSA/TRI April 2012'(04-12)Installation Manual and Table 1 herein.
Exterior Research and Design,4c. Evaluation Report 10880.07.08-117
Certiftaw of Autharization#9503 F1.10454-117
Revision 7:12/17/2015
Page 9.of 10
t'-JI ! 'f ER,D
6_8 ASTM Oreanic Mineral Surface Tile Underlayment:
6.8.1 Shall be installed in compliance with the requirements for ASTM D6380, Class M sheets in FBC Sections
1507 for the type of prepared roof covering to be installed.
6.8.2 Non-Tile Applications:
Reference is made to the current edition of the NRCA Steep-slope Roofing Manual and ARMA
recommendations for installing shingle underlayments and flashings.
6.8.3 Tile Applications:
Reference,is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein. Tile shall be
loaded and staged in a manner that.prevents tile slippage and/or damage to the underlayment.
6_9 LeakBarrier'EasyMop SBS:
6.9.1 Shall be installed in compliance with current Tarco published installation requirements, subject to the
limitations herein.
6.9.2 Non-Tile Applications:
For mechanically, attached applications: Secure LeakBarrier EasyMop SBS using 3/8-inch headed.roofing
nails or 1-inch diameter cap-nails spaced 9-inch o.c.within the 4-inch wide side laps and 12-inch o.c.in two.
(2)equally spaced, staggered center rows in the center of the sheet. End-laps shall be minimum 6-inch
wide,and offset end-laps minimum 3-feet from course to,course. Seal end laps in accordance with Tarco
requirements.
For bonded applications: Fully adhere LeakBarrier EasyMop SBS in hot-asphalt to the substrates noted in
Section S.S. Side laps shall be minimum 4-inch and end-laps minimum 6-inch wide, and offset end=laps
minimum 3-feet from course to course. Side and end-laps,shall be fully adhered in a complete,mopping of
hot asphalt with asphalt extending approximately 3/8-inch beyond .the lap edge. Consult Tarco
instructions regarding back-nailing requirements.
6.9.3 Tile Applications:
Refer to FRSA/TRI,April 2012 (04-12) Installation Manual and Table 1 herein. Tile shall be loaded and
staged in a manner that prevents tile slippage and/or damage to the underlayment.
7. BUILDING PERMIT REQUIREMENTS:
As required.by the Building Official or Authority.Having Jurisdiction in order to properly evaluate the.installation of
this product.
S. MANUFACTURING PLANTS:
Contact the noted OA agency for information on productlocations covered for F.A.C.Rule 61620-3 QA requirements
9. QUALITY ASSURANCE ENTITY:
UL,LLC.—QUA9625;(847)664-3281
-END OF EVALUATION REPORT-
Exterior Research.and Design,LLC. Evaluation Report 10880.07:08-117
eertWcare.ofAarhorizadart#9503
FL 16450:117
Revision 7:12/27/2015.
Page 10 6f.10