HomeMy WebLinkAboutNotice of Acceptance (2) R E C E I b ���D 2017
f . 1 F
Z
MIAMI,11=
! MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF PERMITTING,ENVIRONMENT,AND REGULATORY AFFAIRS(PERA) 11805 SW 26 Street,Room 208
BOARD AND'CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
_NOTICE OF ACCEPTANCE (NOA) www.miamidade.aov/vera
3M Company
3M Center Building 0220-05-E-06
St.Paul,MN.55144-1000
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County PERA-Product Control Section to
be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right
to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: 3MTM 2-Component-Foam Roof Tile Adhesive AH-160
LABELING: Each unit shall bear a permanent label with'the manufacturer's name or logo, city,state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for
sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This renews and revises NOA# 11-0124.04 and consists of pages 1 through 7.
The submitted documentation was reviewed by Alex Tigera.
NOA No.:12-0228.18
QMIAMMI.D�ADE COUNTY Expiration Date:05/10/17
Approval Date: 05/10/12
Page 1 of 7
,4
ROOFING COMPONENT APPROVAL:
Category: Roofing
Sub Category: Roof tile adhesive
Materials: Polyurethane
SCOPE:
This approves 3MTM 2-Component Foam Roof Tile Adhesive AH-160 as manufactured by 3M Company as
described in Section 2 of this Notice of Acceptance.For the locations where the design pressure requirements,as
determined by applicable building code,does not exceed the design pressure values obtained by calculations in
compliance with Roofing Application Standard RAS 127,for use with approved flat,low,and high profile roof tiles
system using 2-Component Foam Roof Tile Adhesive AH-160.Where the attachment calculations are done as a
moment based system for single patty placement,and as an uplift based system for double patty systems
PRODUCTS MANUFACTURED BY APPLICANT:
Product Dimensions Test Product Description
Specifications
3MTM 2-Component Foam N/A TAS 101 Two component polyurethane foam adhesive
Roof Tile Adhesive AH-
160
Foam Dispenser RTF 1000 N/A Dispensing Equipment
ProPack®30& 100 N/A Dispensing Equipment
PRODUCTS MANUFACTURED BY OTHERS:
Any Miami-Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list moment
resistance values with the use of 2-Component Foam Roof Tile Adhesive AH-160
roof tile adhesive.
MANUFACTURING LOCATION:
1. Tomball,TX.
PHYSICAL PROPERTIES:
Pro a Test Results
Density ASTM D 1622 1.6lbs./ft.3
Compressive Strength ASTM D 1621 18 PSI Parallel to rise
12 PSI Perpendicular to rise
Tensile Strength ASTM D 1623 28 PSI Parallel to rise
Water Absorption ASTM D 2127 0.08 Lbs./Fe
Moisture Vapor Transmission ASTM E 96 3.1 Perm/Inch
Dimensional Stability ASTM D 2126 +0.07%Volume Change @-40°F.,2 weeks
+6.0%Volume Change @158°F., 100%Humidity,2
weeks
Closed Cell Content ASTM D 2856 86%
NOA No.:12-0228.18
MIAMI•DADE COUNTY Expiration Date:05/10/17
..., 1 Approval Date: 05/10/12
Page 2 of 7
Note: The physical properties listed above are presented as typical average values as determined
by accepted ASTM test methods and are subject to normal manufacturing variation.
EVIDENCE SUBMITTED:
Test Asency Test Identifier Test Name/Report Date
Center for Applied Engineering #94-060 TAS 101 04/08/94
257818-IPA TAS 101 12/16/96
25-7438-3 SSTD 11-93 10/25/95
25-7438-4
25-7438-7 SSTD 11-93 11/02/95
25-7492 SSTD 11-93 12/12/95
Miles Laboratories NB-589-631 ASTM D 1623 02/01/94
Polymers Division
Ramtech Laboratories,Inc. 9637-92 ASTM E 108 04/30/93
Southwest Research Institute 01-6743-011 ASTM E 108 11/16/94
01-6739-062b[l] ASTM E 84 01/16/95
Trinity Engineering 7050.02.96-1 TAS 114 03/14/96
Celotex Corp.Testing Services 528454-2-1 TAS 101 10/23/98
528454-9-1
528454-10-1
520109-1 TAS 101 12/28/98
520109-2
520109-3
520109-6
520109-7
520191-1 TAS 101 03/02/99
520109-2-1
LIMITATIONS:
1. Fire classification is not part of this acceptance.Refer to the Prepared Roof Tile Assembly for fire rating.
2. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall solely be used with flat,low,&high tile profiles.
3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120.
4. Roof Tile manufactures acquiring acceptance for the use of 3MTM 2-Component Foam Roof Tile Adhesive AH-
160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101.
5. Roof Tile manufactures acquiring acceptance for the use of HANDI-STICK roof tile adhesive with their tile
assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein.
F — W
2
F'=
MS
NOA No.:12-0228.18
ar�uaoe couNrir Expiration Date:05/10/17
Mi
A Approval Date:05/10/12
Page 3 of 7
INSTALLATION:
1. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 may be used with any roof tile assembly having a current
NOA that lists uplift resistance values with the use of 3MTM 2-Component Foam Roof Tile Adhesive AH-160.
2. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall be applied in compliance with the Component
Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive
attachment with the use of 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall provide sufficient
attachment resistance,expressed as an uplift based system,to meet or exceed the uplift resistance determined in
compliance with Miami-Dade County Roofing Application Standards RAS 127. The adhesive attachment data is
noted in the roof tile assembly NOA.
3. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 and its components shall be installed in accordance with
Roofing Application Standard RAS 120,and 3M Company's 3MTM 2-Component Foam Roof Tile Adhesive AH-
160 Operating Instruction and Maintenance Booklet.
4. Installation must be by a Factory Trained'Qualified Applicator'approved and licensed by 3M Company. 3M
Company shall supply a list of approved applicators to the authority having jurisdiction.
5. Calibration of the Foam Dispenser RTF 1000 dispensing equipment is required before application of any adhesive.
The mix ratio between the"A" component and the"B"component shall be maintained between 1.0-1.15 (A): 1.0
(B). The dispense timer shall beset to deliver 0.0175 to 0.15 pounds per tile as determined at calibration. No
other settings shall be approved.
6. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall be applied with Foam Dispenser RTF 1000 or
ProPack®30& 100 dispensing equipment only.
7. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall not be exposed permanently to sunlight.
8. Tiles must be adhered in freshly applied adhesive.Tile must be set within 2 to 3 minutes after 3MTM 2-
Component Foam Roof Tile Adhesive AH-160 has been dispensed.
9. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 placement and minimum patty weight shall be in
accordance with the'Placement Details'herein. Each generic tile profile requires the specific placement noted
herein.
Table 1:Adhesive Placement For Each Generic Tile Profile
Tile Profile Placement Detail Single Paddy Weight Two Paddy Weight per
Min.(grams) paddy Min.(grams)
Flat,Low,High Profiles #1 35 N/A
High Profile 2 Piece Barrel #1 17/side on cap and 34/ an N/A
Flat,Low,High Profiles #2 24 N/A
Flat,Low,High Profiles #3 1 8
NOA No.: 12-0228.18
htiarn•DADe CO2NTym Expiration Date:05/10/17
Approval Date:05/10/12
Page 4 of 7
LABELING:
All 3MTM 2-Component Foam Roof Tile Adhesive AH-160 containers shall comply with the Standard Conditions
listed herein.
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or applicable building code in order to properly evaluate the installation of this
system.
ADHESIVE PLACEMENT DETAIL 1
SINGLE PATTY
Nail through plastic cement Paddy(Beneath Tile) Nail through plastic cement
Paddy(Beneath Tile)
Undedayment Undedayment
1 1 ---
10 In.
EeveCourse
Fascia Eave Course Fascia
weep*
Eave course only: Eave course only: Eave closure
Eave Closure Keep adhesive approx. Keep adhesive approx. Drip edge
4In.upfrom weepholes 1 4 In.up from weepholes
Nail through plastic cement Paddy(Beneath Tile) to Optional2As for
1)Place enough In contact
to achieve n He23 steep pitch applications Nail through plastic cement
Un�dayment _-=-_ square Inches In contact with the pan UIe
2)Tum covers upside down.Place adhesive W In.
To 1 In.From outside edge of cover tile.
Then install the file. o
- - Undedayment
10 In.
Eave Course
/ o
Eave Closure Remov
Eave course only: to Bion =
Keep adhesive approx.4 in.up Fascia ofthe save _ Sheathing
lromweepholes course cover4le. /
Abultosecon courseoI Optional
pantiles.Ensure eava end of Point trp Mortar
and covertiles are
flush at save line. on longitudinal
edges of file
Eave closure Weephote Fascia Be r
(mortar shown)
NOA No.:12-0228.18
Expiration Date: 05/10/17
MIAMI DAD;COUNTY Approval Date:05/10/12
Page 5 of 7
5
ADHESIVE PLACEMENT DETAIL 2
SINGLE PATTY
Nall through plastic cement Paddy(Beneath Tile) Nall through plastic cement Paddy(Beneath Tile)
Underlayment Undedayment
1 _
71n. 2 in.
7 in.
2 In.
EaVaCcume
Fascia Fascia
% Wephole
Eave Course Eave closure
Eave Closure Drip edge
Nail through plastic cement Paddy(Beneath Tile)
Undeflayment
71n.
In.
Eave Closure
Eave Course Fascia
NOA No.:12-0228.18
MIAMI•DADE COUNTY Expiration Date:05/10/17
Approval Date: 05/10/12
Page 6 of 7
ADHESIVE PLACEMENT DETAIL 3
DOUBLE PATTY
Nall through plastic cement Paddy Nall through plastic cement Single paddy under tile
(between tile) Undedayment Single paddy between file
Paddy 2 In,x 7 In.medium
0 (under 019) size paddy eave
course only
C
Single paddy 3 04,1-34'-1 in.x 3 in
SinUnder the
x 3 in In. 2 In.
Sin gle padd'y on 2 in. 4 In. Single
under- paddy on
layment under-
layment
Single paddy Fascia
Eave course on top of the Weephole
Single paddy 2 In.X 7 In.medium VEave closure
on top of tile size paddy eave % Couese rDrip edge
Fascia course only
Nail through plastic cement Single paddy
under tale Single paddy
between the
3 In.x 3 In. 41n.
Single paddy
on undedayment 2 in.
Single paddy Eave Closure
on top of tile 2 In.x 7 In,medium .
size paddy eave course only
Eave Course Fascia
L- I
END OF THIS ACCEPTANCE
NOA No.:12-0228.18
MIAMI-RADE couNTY
Expiration Date:05/10/17
Approval Date:05/10/12
Page 7 of 7
'JZ5fir' s`Q, ,
RECEIVED FEB 212017
MIAMI-DADE COUNTY
MIAMI-__ PRODUCT CONTROL SECTION
•e 11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
Entegra Roof Tile,LLC
1289 NE 9'Ave
Okeechobee,FL.34972
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section(in
Miami-Dade County) and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this product or
material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of
such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,if it is determined by
Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable
building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code including
the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Estate"S"Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in
the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall
be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No. 14-1120.08 and consists of pages 1 through 6.
The submitted documentation was reviewed by Gaspar J Rodriguez.
NOA No.16-0112.08
MiAMi-DADe couNTY Expiration Date: 08/23/21
Approval Date:02/25/16
Page 1 of 6
s
•1 4'..'a .$ F.
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub Category: Roofing Tiles
Material: Concrete
1. SCOPE
This approves a roofing system using Entegra Estate"S" Concrete Roof Tile, as manufactured by Entegra Roof Tile,
LLC in Okeechobee, FL as described in Section 2 of this Notice of Acceptance, designed to comply with the Florida
Building Code for High Velocity Hurricane Zone. For use in the locations where the pressure requirements,as determined
by applicable Building Code, do not exceed the design pressure values obtain by calculations in compliance with RAS
127 using the values listed in section 4 herein. The attachment calculations shall be prepared as a moment based system.
2. PRODUCT DESCRIPTION
Manufactured by Dimensions Test Product
Applicant Specifications Description
Entegra Estate `S'Roof Length= 16-1/2" TAS 112 Low profile,interlocking,extruded
Tile Width= 13" Type lb concrete roof tile equipped with two nail
Class III hole and double roll ribs. For direct deck
or battened nail-on,mortar or adhesive
set applications.
Trim Pieces 1=varies TAS 112 Accessory trim,concrete roof pieces for
w=varies use at hips,rakes,ridges and valley
varying thickness terminations. Manufactured for each tile
profile.
2.1 MANUFACTURING LOCATION
1. Okeechobee,FL
NOA No.16-0112.08
Miami ohne couNnr Expiration Date: 08/23/21
Approval Date: 02/25/16
Page 2 of 6
2.2 EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Report Date
Redland Technologies 7161-03 PA 102 Dec. 1991
7161-03 PA 102(A) Dec. 1991
7161-03 PA 108 Dec. 1991
P0402 Withdrawal Resistance Testing of Sept. 1993
screw vs. smooth shank nails
P0631-01 PA 108 July 1994
Letter Dated Aug. 1, PA 108 Aug. 1994
1994
Professional Service Industries,Inc. 224-47099 PA 112 Sept. 1994
The Center for Applied 94-060B PA 101 March, 1994
Engineering,Inc. 94-084 PA 101 May 1994
25-7094-1 PA 102 Oct. 1994
25-7094-7 PA 102 Oct. 1994
25-7094-4 PA 102 Oct. 1994
Project No. 307025 PA 100 Oct. 1994
Test#MDC-76
25-7183-1 PA 102 Feb. 1995
25-7183-2 PA 102 Feb. 1995
25-7214-2 PA 102 March, 1995
25-7214-6 PA 102 March, 1995
Celotex Corporation Testing Services 528454-2-1 PA 101 Sep. 1998
520109-2 Dec. 1998
Walker Engineering,Inc. Calculations Aerodynamic Multiplier March 1999
IBA Consultants,Inc. 2381-264 TAS 112 01/08/08
American Test Lab of South Florida RT1210.03-15 TAS 112 12/17/15
3. LIMITATIONS:
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications,a static field uplift test in accordance with.TAS 106 may
required,refer to applicable building code.
3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test in
accordance with TAS 112,appendix `A'. Such testing shall be submitted to the Miami-Dade Product
Control Section for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable building code.
NOA No.16-0112.08
MIAMI-DAD,COUNTY Expiration Date: 08/23/21
Approval Date:02/25/16
Page 3 of 6
4. INSTALLATION
4.1 Entegra Estate"S"Concrete Roof Tile and its components shall be installed in strict compliance with Miami
Dade County Roofing Application Standard RAS 118,RAS 119,and RAS 120.
4.2 Data For Attachment Calculations.
Table 1: Average Weight(W) and Dimensions (I x w)
Tile Profile Weight-W(lbf) Length-1 (ft) Width-w(ft)
Entegra Estate 'S' Roof Tile 10.0 1.375 1.08
Table 2: Aerodynamic Multipliers -,% (ft3)
Tile 1(ft3) 1(ft3)
Profile Batten Application Direct Deck Application
Entegra Estate 'S' Roof Tile 0.267 0.289
Table 3: Restoring Moments due to Gravity-Mg (ft-lbf)
Tile 311:12" 4":12" 5":12" 6":12" Greater than
Profile 7':12"
Entegra Estate Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct
'S' Roof Tile Deck Deck Deck Deck Deck
5.91 6.74 5.82 6.64 5.70 6.50 5.56 6.33 5.40 6.14
Table 4: Attachment Resistance Expressed as a Moment- Mf(ft-lbf)
for Nail-On Systems
Tile Fastener Type Direct Deck Direct Deck Battens
Profile (min 15/32" plywood) (min. 19/32" plywood)
Entegra 2-10d Ring Shank Nails 27.8 37.4 28.8
Estate 'S' 1-10d Smooth or Screw 8.8 11.8 4.1
Roof Tile Shank Nai12
2-10d Smooth or Screw 16.4 21.9 7.1
Shank Nails
1 #8 Screw2 25.8 25.8 22.9
2#8 Screw 47.1 47.1 49.1
1-10d Smooth or Screw 24.3 24.3 24.2
Shank Nail Field Cli 2
1-10d Smooth or Screw 19.0 19.0 22.1
Shank Nail Eave Cli 2
2-10d Smooth or Screw 35.5 35.5 34.8
Shank Nails Field Clip)
2-10d Smooth or Screw 31.9 31.9 32.2
Shank Nails Eave Cli
2-10d Ring Shank Nails' 43.0 67.5 50.9
1 Installation with a 4"tile headlap and fasteners are located a min.of 2'/2'from head of tile.
2 When using only one fastener use the hole that is approximately 4-3/4"away from interlocking edge.
NOA No.16-0112.08
MiArn•oaDE COUNTY Expiration Date: 08/23/21
Approval Date:02/25/16
Page 4 of 6
P--�
F 15
Table 5: Attachment Resistance Expressed as a Moment Mf(ft-lbf)
for Two Patty Adhesive Set Systems
Tile Tile Application Minimum Attachment Resistance
Profile
Entegra Estate 'S' Roof Tile Adhesive 26.14
3 See manufactures component approval for installation requirements.
4 Flexible Products Company TileBond Average weight per patty 11.4 grams.
3M''2-Component Foam Roof Tile Adhesive AH-160 Average weight per patty 8 grams.
Table 6: Attachment Resistance Expressed as a Moment-Mf(ft-lbf)
for Single Patty Adhesive Set Systems
Tile Tile Application Minimum Attachment
Profile Resistance
Entegra Estate 'S' Roof 3M'' 2-Component Foam Roof Tile Adhesive AH-160 86.615
Tile 3M'" 2-Component Foam Roof Tile Adhesive AH-160 45.56
5 Large paddy placement of 54 grams of 3M' 2-Component Foam Roof Tile Adhesive AH-160
6 Medium paddy placement of 24 grams of 3M"° 2-Component Foam Roof Tile Adhesive AH-160.
Table 7: Attachment Resistance Expressed as a Moment-Mf(ft-lbf)
for Mortar or Adhesive Set Systems
Tile Tile Application Minimum Attachment
Profile Resistance
Entegra Estate 'S' Mortar Set 20.60
Roof Tile
5. LABELING
All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen below or following
statement: "Miami-Dade County Product Control Approved".
OR
7��7
E H T E 0 R R
ESTATE"S"TILE LABEL(LOCATED ON UNDERSIDE OF TILE
NOA No.16-0112.08
QMMLAMI-�DADE couNTtt Expiration Date: 08/23/21
Approval Date:02/25/16
Page 5 of 6
.�
e
6. BUILDING PERMIT REQUIREMENTS:
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by Building Official or Applicable building code in order to properly
evaluate the installation of this system.
PROFILE DRAWING
Nail Holes
•
•
1
ENTEGRA ESTATE"S" CONCRETE ROOF TILE
END OF THIS ACCEPTANCE
NOA No.16-0112.08
MIAMI•DADECOUNTY Expiration Date: 08/23/21
�Fgauxqyo Approval Date:02/25/16
Page 6 of 6