Loading...
HomeMy WebLinkAboutNotice of Acceptance (2) R E C E I b ���D 2017 f . 1 F Z MIAMI,11= ! MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING,ENVIRONMENT,AND REGULATORY AFFAIRS(PERA) 11805 SW 26 Street,Room 208 BOARD AND'CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 _NOTICE OF ACCEPTANCE (NOA) www.miamidade.aov/vera 3M Company 3M Center Building 0220-05-E-06 St.Paul,MN.55144-1000 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County PERA-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: 3MTM 2-Component-Foam Roof Tile Adhesive AH-160 LABELING: Each unit shall bear a permanent label with'the manufacturer's name or logo, city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews and revises NOA# 11-0124.04 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigera. NOA No.:12-0228.18 QMIAMMI.D�ADE COUNTY Expiration Date:05/10/17 Approval Date: 05/10/12 Page 1 of 7 ,4 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves 3MTM 2-Component Foam Roof Tile Adhesive AH-160 as manufactured by 3M Company as described in Section 2 of this Notice of Acceptance.For the locations where the design pressure requirements,as determined by applicable building code,does not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127,for use with approved flat,low,and high profile roof tiles system using 2-Component Foam Roof Tile Adhesive AH-160.Where the attachment calculations are done as a moment based system for single patty placement,and as an uplift based system for double patty systems PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product Description Specifications 3MTM 2-Component Foam N/A TAS 101 Two component polyurethane foam adhesive Roof Tile Adhesive AH- 160 Foam Dispenser RTF 1000 N/A Dispensing Equipment ProPack®30& 100 N/A Dispensing Equipment PRODUCTS MANUFACTURED BY OTHERS: Any Miami-Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list moment resistance values with the use of 2-Component Foam Roof Tile Adhesive AH-160 roof tile adhesive. MANUFACTURING LOCATION: 1. Tomball,TX. PHYSICAL PROPERTIES: Pro a Test Results Density ASTM D 1622 1.6lbs./ft.3 Compressive Strength ASTM D 1621 18 PSI Parallel to rise 12 PSI Perpendicular to rise Tensile Strength ASTM D 1623 28 PSI Parallel to rise Water Absorption ASTM D 2127 0.08 Lbs./Fe Moisture Vapor Transmission ASTM E 96 3.1 Perm/Inch Dimensional Stability ASTM D 2126 +0.07%Volume Change @-40°F.,2 weeks +6.0%Volume Change @158°F., 100%Humidity,2 weeks Closed Cell Content ASTM D 2856 86% NOA No.:12-0228.18 MIAMI•DADE COUNTY Expiration Date:05/10/17 ..., 1 Approval Date: 05/10/12 Page 2 of 7 Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. EVIDENCE SUBMITTED: Test Asency Test Identifier Test Name/Report Date Center for Applied Engineering #94-060 TAS 101 04/08/94 257818-IPA TAS 101 12/16/96 25-7438-3 SSTD 11-93 10/25/95 25-7438-4 25-7438-7 SSTD 11-93 11/02/95 25-7492 SSTD 11-93 12/12/95 Miles Laboratories NB-589-631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories,Inc. 9637-92 ASTM E 108 04/30/93 Southwest Research Institute 01-6743-011 ASTM E 108 11/16/94 01-6739-062b[l] ASTM E 84 01/16/95 Trinity Engineering 7050.02.96-1 TAS 114 03/14/96 Celotex Corp.Testing Services 528454-2-1 TAS 101 10/23/98 528454-9-1 528454-10-1 520109-1 TAS 101 12/28/98 520109-2 520109-3 520109-6 520109-7 520191-1 TAS 101 03/02/99 520109-2-1 LIMITATIONS: 1. Fire classification is not part of this acceptance.Refer to the Prepared Roof Tile Assembly for fire rating. 2. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall solely be used with flat,low,&high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of 3MTM 2-Component Foam Roof Tile Adhesive AH- 160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. Roof Tile manufactures acquiring acceptance for the use of HANDI-STICK roof tile adhesive with their tile assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein. F — W 2 F'= MS NOA No.:12-0228.18 ar�uaoe couNrir Expiration Date:05/10/17 Mi A Approval Date:05/10/12 Page 3 of 7 INSTALLATION: 1. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 may be used with any roof tile assembly having a current NOA that lists uplift resistance values with the use of 3MTM 2-Component Foam Roof Tile Adhesive AH-160. 2. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall provide sufficient attachment resistance,expressed as an uplift based system,to meet or exceed the uplift resistance determined in compliance with Miami-Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 and its components shall be installed in accordance with Roofing Application Standard RAS 120,and 3M Company's 3MTM 2-Component Foam Roof Tile Adhesive AH- 160 Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained'Qualified Applicator'approved and licensed by 3M Company. 3M Company shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the Foam Dispenser RTF 1000 dispensing equipment is required before application of any adhesive. The mix ratio between the"A" component and the"B"component shall be maintained between 1.0-1.15 (A): 1.0 (B). The dispense timer shall beset to deliver 0.0175 to 0.15 pounds per tile as determined at calibration. No other settings shall be approved. 6. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall be applied with Foam Dispenser RTF 1000 or ProPack®30& 100 dispensing equipment only. 7. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive.Tile must be set within 2 to 3 minutes after 3MTM 2- Component Foam Roof Tile Adhesive AH-160 has been dispensed. 9. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 placement and minimum patty weight shall be in accordance with the'Placement Details'herein. Each generic tile profile requires the specific placement noted herein. Table 1:Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Single Paddy Weight Two Paddy Weight per Min.(grams) paddy Min.(grams) Flat,Low,High Profiles #1 35 N/A High Profile 2 Piece Barrel #1 17/side on cap and 34/ an N/A Flat,Low,High Profiles #2 24 N/A Flat,Low,High Profiles #3 1 8 NOA No.: 12-0228.18 htiarn•DADe CO2NTym Expiration Date:05/10/17 Approval Date:05/10/12 Page 4 of 7 LABELING: All 3MTM 2-Component Foam Roof Tile Adhesive AH-160 containers shall comply with the Standard Conditions listed herein. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. ADHESIVE PLACEMENT DETAIL 1 SINGLE PATTY Nail through plastic cement Paddy(Beneath Tile) Nail through plastic cement Paddy(Beneath Tile) Undedayment Undedayment 1 1 --- 10 In. EeveCourse Fascia Eave Course Fascia weep* Eave course only: Eave course only: Eave closure Eave Closure Keep adhesive approx. Keep adhesive approx. Drip edge 4In.upfrom weepholes 1 4 In.up from weepholes Nail through plastic cement Paddy(Beneath Tile) to Optional2As for 1)Place enough In contact to achieve n He23 steep pitch applications Nail through plastic cement Un�dayment _-=-_ square Inches In contact with the pan UIe 2)Tum covers upside down.Place adhesive W In. To 1 In.From outside edge of cover tile. Then install the file. o - - Undedayment 10 In. Eave Course / o Eave Closure Remov Eave course only: to Bion = Keep adhesive approx.4 in.up Fascia ofthe save _ Sheathing lromweepholes course cover4le. / Abultosecon courseoI Optional pantiles.Ensure eava end of Point trp Mortar and covertiles are flush at save line. on longitudinal edges of file Eave closure Weephote Fascia Be r (mortar shown) NOA No.:12-0228.18 Expiration Date: 05/10/17 MIAMI DAD;COUNTY Approval Date:05/10/12 Page 5 of 7 5 ADHESIVE PLACEMENT DETAIL 2 SINGLE PATTY Nall through plastic cement Paddy(Beneath Tile) Nall through plastic cement Paddy(Beneath Tile) Underlayment Undedayment 1 _ 71n. 2 in. 7 in. 2 In. EaVaCcume Fascia Fascia % Wephole Eave Course Eave closure Eave Closure Drip edge Nail through plastic cement Paddy(Beneath Tile) Undeflayment 71n. In. Eave Closure Eave Course Fascia NOA No.:12-0228.18 MIAMI•DADE COUNTY Expiration Date:05/10/17 Approval Date: 05/10/12 Page 6 of 7 ADHESIVE PLACEMENT DETAIL 3 DOUBLE PATTY Nall through plastic cement Paddy Nall through plastic cement Single paddy under tile (between tile) Undedayment Single paddy between file Paddy 2 In,x 7 In.medium 0 (under 019) size paddy eave course only C Single paddy 3 04,1-34'-1 in.x 3 in SinUnder the x 3 in In. 2 In. Sin gle padd'y on 2 in. 4 In. Single under- paddy on layment under- layment Single paddy Fascia Eave course on top of the Weephole Single paddy 2 In.X 7 In.medium VEave closure on top of tile size paddy eave % Couese rDrip edge Fascia course only Nail through plastic cement Single paddy under tale Single paddy between the 3 In.x 3 In. 41n. Single paddy on undedayment 2 in. Single paddy Eave Closure on top of tile 2 In.x 7 In,medium . size paddy eave course only Eave Course Fascia L- I END OF THIS ACCEPTANCE NOA No.:12-0228.18 MIAMI-RADE couNTY Expiration Date:05/10/17 Approval Date:05/10/12 Page 7 of 7 'JZ5fir' s`Q, , RECEIVED FEB 212017 MIAMI-DADE COUNTY MIAMI-__ PRODUCT CONTROL SECTION •e 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy Entegra Roof Tile,LLC 1289 NE 9'Ave Okeechobee,FL.34972 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section(in Miami-Dade County) and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Estate"S"Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No. 14-1120.08 and consists of pages 1 through 6. The submitted documentation was reviewed by Gaspar J Rodriguez. NOA No.16-0112.08 MiAMi-DADe couNTY Expiration Date: 08/23/21 Approval Date:02/25/16 Page 1 of 6 s •1 4'..'a .$ F. ROOFING ASSEMBLY APPROVAL Category: Roofing Sub Category: Roofing Tiles Material: Concrete 1. SCOPE This approves a roofing system using Entegra Estate"S" Concrete Roof Tile, as manufactured by Entegra Roof Tile, LLC in Okeechobee, FL as described in Section 2 of this Notice of Acceptance, designed to comply with the Florida Building Code for High Velocity Hurricane Zone. For use in the locations where the pressure requirements,as determined by applicable Building Code, do not exceed the design pressure values obtain by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be prepared as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Dimensions Test Product Applicant Specifications Description Entegra Estate `S'Roof Length= 16-1/2" TAS 112 Low profile,interlocking,extruded Tile Width= 13" Type lb concrete roof tile equipped with two nail Class III hole and double roll ribs. For direct deck or battened nail-on,mortar or adhesive set applications. Trim Pieces 1=varies TAS 112 Accessory trim,concrete roof pieces for w=varies use at hips,rakes,ridges and valley varying thickness terminations. Manufactured for each tile profile. 2.1 MANUFACTURING LOCATION 1. Okeechobee,FL NOA No.16-0112.08 Miami ohne couNnr Expiration Date: 08/23/21 Approval Date: 02/25/16 Page 2 of 6 2.2 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Redland Technologies 7161-03 PA 102 Dec. 1991 7161-03 PA 102(A) Dec. 1991 7161-03 PA 108 Dec. 1991 P0402 Withdrawal Resistance Testing of Sept. 1993 screw vs. smooth shank nails P0631-01 PA 108 July 1994 Letter Dated Aug. 1, PA 108 Aug. 1994 1994 Professional Service Industries,Inc. 224-47099 PA 112 Sept. 1994 The Center for Applied 94-060B PA 101 March, 1994 Engineering,Inc. 94-084 PA 101 May 1994 25-7094-1 PA 102 Oct. 1994 25-7094-7 PA 102 Oct. 1994 25-7094-4 PA 102 Oct. 1994 Project No. 307025 PA 100 Oct. 1994 Test#MDC-76 25-7183-1 PA 102 Feb. 1995 25-7183-2 PA 102 Feb. 1995 25-7214-2 PA 102 March, 1995 25-7214-6 PA 102 March, 1995 Celotex Corporation Testing Services 528454-2-1 PA 101 Sep. 1998 520109-2 Dec. 1998 Walker Engineering,Inc. Calculations Aerodynamic Multiplier March 1999 IBA Consultants,Inc. 2381-264 TAS 112 01/08/08 American Test Lab of South Florida RT1210.03-15 TAS 112 12/17/15 3. LIMITATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications,a static field uplift test in accordance with.TAS 106 may required,refer to applicable building code. 3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112,appendix `A'. Such testing shall be submitted to the Miami-Dade Product Control Section for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. NOA No.16-0112.08 MIAMI-DAD,COUNTY Expiration Date: 08/23/21 Approval Date:02/25/16 Page 3 of 6 4. INSTALLATION 4.1 Entegra Estate"S"Concrete Roof Tile and its components shall be installed in strict compliance with Miami Dade County Roofing Application Standard RAS 118,RAS 119,and RAS 120. 4.2 Data For Attachment Calculations. Table 1: Average Weight(W) and Dimensions (I x w) Tile Profile Weight-W(lbf) Length-1 (ft) Width-w(ft) Entegra Estate 'S' Roof Tile 10.0 1.375 1.08 Table 2: Aerodynamic Multipliers -,% (ft3) Tile 1(ft3) 1(ft3) Profile Batten Application Direct Deck Application Entegra Estate 'S' Roof Tile 0.267 0.289 Table 3: Restoring Moments due to Gravity-Mg (ft-lbf) Tile 311:12" 4":12" 5":12" 6":12" Greater than Profile 7':12" Entegra Estate Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct 'S' Roof Tile Deck Deck Deck Deck Deck 5.91 6.74 5.82 6.64 5.70 6.50 5.56 6.33 5.40 6.14 Table 4: Attachment Resistance Expressed as a Moment- Mf(ft-lbf) for Nail-On Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile (min 15/32" plywood) (min. 19/32" plywood) Entegra 2-10d Ring Shank Nails 27.8 37.4 28.8 Estate 'S' 1-10d Smooth or Screw 8.8 11.8 4.1 Roof Tile Shank Nai12 2-10d Smooth or Screw 16.4 21.9 7.1 Shank Nails 1 #8 Screw2 25.8 25.8 22.9 2#8 Screw 47.1 47.1 49.1 1-10d Smooth or Screw 24.3 24.3 24.2 Shank Nail Field Cli 2 1-10d Smooth or Screw 19.0 19.0 22.1 Shank Nail Eave Cli 2 2-10d Smooth or Screw 35.5 35.5 34.8 Shank Nails Field Clip) 2-10d Smooth or Screw 31.9 31.9 32.2 Shank Nails Eave Cli 2-10d Ring Shank Nails' 43.0 67.5 50.9 1 Installation with a 4"tile headlap and fasteners are located a min.of 2'/2'from head of tile. 2 When using only one fastener use the hole that is approximately 4-3/4"away from interlocking edge. NOA No.16-0112.08 MiArn•oaDE COUNTY Expiration Date: 08/23/21 Approval Date:02/25/16 Page 4 of 6 P--� F 15 Table 5: Attachment Resistance Expressed as a Moment Mf(ft-lbf) for Two Patty Adhesive Set Systems Tile Tile Application Minimum Attachment Resistance Profile Entegra Estate 'S' Roof Tile Adhesive 26.14 3 See manufactures component approval for installation requirements. 4 Flexible Products Company TileBond Average weight per patty 11.4 grams. 3M''2-Component Foam Roof Tile Adhesive AH-160 Average weight per patty 8 grams. Table 6: Attachment Resistance Expressed as a Moment-Mf(ft-lbf) for Single Patty Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance Entegra Estate 'S' Roof 3M'' 2-Component Foam Roof Tile Adhesive AH-160 86.615 Tile 3M'" 2-Component Foam Roof Tile Adhesive AH-160 45.56 5 Large paddy placement of 54 grams of 3M' 2-Component Foam Roof Tile Adhesive AH-160 6 Medium paddy placement of 24 grams of 3M"° 2-Component Foam Roof Tile Adhesive AH-160. Table 7: Attachment Resistance Expressed as a Moment-Mf(ft-lbf) for Mortar or Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance Entegra Estate 'S' Mortar Set 20.60 Roof Tile 5. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen below or following statement: "Miami-Dade County Product Control Approved". OR 7��7 E H T E 0 R R ESTATE"S"TILE LABEL(LOCATED ON UNDERSIDE OF TILE NOA No.16-0112.08 QMMLAMI-�DADE couNTtt Expiration Date: 08/23/21 Approval Date:02/25/16 Page 5 of 6 .� e 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. PROFILE DRAWING Nail Holes • • 1 ENTEGRA ESTATE"S" CONCRETE ROOF TILE END OF THIS ACCEPTANCE NOA No.16-0112.08 MIAMI•DADECOUNTY Expiration Date: 08/23/21 �Fgauxqyo Approval Date:02/25/16 Page 6 of 6